NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, January 2, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/food/Listings.asp?Standard=003&Company=23300&
NSF/ANSI 3
Commercial Warewashing Equipment
Commercial Warewashing Equipment
For informational purposes, the estimated racks per hour or dishes per hour for NSF/ANSI 3 Certified dishwashers can be calculated as follows:
Racks per Hour for Stationary Rack Dishwashers = 3600(NR) / TC
Racks per Hour for Rack Conveyor Dishwashers = (CS)(60) / RL
Dishes per Hour for Rackless Conveyor Dishwashers = (120)(CS)(CW) / PD
Water Consumption (gallons per hour) for Stationary Rack Dishwashers = (GPC)(RPH)
Water Consumption (gallons per hour) for Conveyor Dishwashers = (GPM)(60)
Where: CS = Conveyor speed measured in feet per minute
CW = Conveyor width measured in inches
GPC = Gallons per cycle
GPM = Gallons per minute
NR = Number of racks the dishwasher is designed to hold per cycle
PD = Distance between pegs measured in inches, center to center of the peg, in the direction of conveyor travel
RL = Length of the rack measured in feet
RPH = Racks per hour
TC = Total cycle time measured in seconds
The total cycle time includes wash, rinse, dwell, and load times. Load times will vary depending on the type of dishwasher. Estimated load times commonly used for specific types of dishwashers are as follows:
door type (straight thru) - 5 seconds
door type (corner) - 7 seconds
hood type - 8 seconds
front opening type - 30 seconds
Insinger Machine Company (The) | |
6245 State Road | |
Philadelphia, PA 19135 | |
United States | |
215-624-4800 | |
Visit this company's website |
Facility : Philadelphia, PA
CONVEYOR DISHWASHING MACHINES
Final Rinse | ||||||||
(20 psi) | Conveyor Speed | |||||||
Model | Conveyor | Flow | Usage | (Max.) | Footnotes | |||
Number | Width | gpm | gph | (ft/min.) | ||||
Single Tank Rack Conveyor, Hot Water Sanitizing |
||||||||
Admiral 44-4 | 20x20 | 2.5 | 147 | 6.4 | ||||
Admiral 66-4 | 20x20 | 2.5 | 147 | 6.4 | ||||
Tray Washer Multiple Tank Conveyor, Hot Water Sanitizing |
||||||||
TRAC 321-2 | N/A | 4.14 | 248 | 11 | [1] [9] | |||
TRAC-878 | N/A | 3.28 | 196.64 | 18.3 | [9] | |||
[1] These conveyor type machines may be furnished with RPW recirculating pre-wash, built integral with the machines as accessory equipment. Water comes from wash water overflow only. [9] Acceptable with a power scrapper, TD-321-2 tray dryer, and/or tray stacker. |
||||||||
Multiple Tank Rack Conveyor, Hot Water Sanitizing |
||||||||
GalleyMaster 135 | 20x20 | 4.0 | 240 | 3.7 | [4] [8] | |||
GalleyMaster 185 | 20x20 | 4.0 | 240 | 5.1 | [4] [8] | |||
GalleyMaster 250 | 20x20 | 4.0 | 240 | 7 | [4] [8] | |||
GalleyMaster 60 | 20x20 | 4.0 | 240 | 1.6 | [4] [8] | |||
GalleyMaster 85 | 20x20 | 4.0 | 240 | 2.3 | [4] [8] | |||
R-106-2 | 20x20 | 2 | 240 | 10 | [1] | |||
Speeder 64 | 20x20 | 2.4 | 144 | 7.7 | [5] | |||
Speeder 86-3 | 20x20 | 2.4 | 144 | 7.7 | ||||
Super 106-2 | 20x20 | 4 | 240 | 9.2 | ||||
[1] These conveyor type machines may be furnished with RPW recirculating pre-wash, built integral with the machines as accessory equipment. Water comes from wash water overflow only. [4] Listing with suffix LH or RH (for left to right or right to left conveyor direction) and with suffix S or E (for steam or electric tank and booster heat). [5] With beginning serial number 938038. [8] Make-up water is provided from final rinse source of supply. Sizing of water heaters should be based on additional demand (not to exceed .9 gpm). |
||||||||
Multiple Tank Rackless Conveyor, Hot Water Sanitizing |
||||||||
Century 14 | 26 | 3.8 | 228 | 7 | [6] | |||
[6] The peg spacing for rackless conveyor dishwasher models Century, Clipper, and Master is 2 1/2", center to center. |
||||||||
COMPONENTS: |
||||||||
Multiple Tank Rack Conveyor, Chemical Sanitizing |
||||||||
Speeder 64CS | 20x20 | 2.4 | 144 | 7.7 | [5] [10] | |||
Speeder 86-3CS | 20x20 | 2.4 | 144 | 7.7 | [10] | |||
Super 106-2CS | 20x20 | 4 | 240 | 9.2 | [10] | |||
[5] With beginning serial number 938038. [10] Nonrecirculated, fresh water, final rinse, 50 ppm available chlorine. |
||||||||
Single Tank Rack Conveyor, Chemical Sanitizing |
||||||||
Admiral 44-4CS | 20x20 | 2.5 | 147 | 6.4 | [10] | |||
Admiral 66-4CS | 20x20 | 2.5 | 147 | 6.4 | [10] | |||
[10] Nonrecirculated, fresh water, final rinse, 50 ppm available chlorine. |
[2] (1) represents length of dishmachine, in feet (18 - 33). [3] (1) represents length of dishmachine, in feet (16 - 31). [7] Unit is a four tank machine.
STATIONARY RACK DISHWASHING MACHINES
Final Rinse | ||||||||
(20 psi) | Operating Time | |||||||
Model | Rack Size | Flow | Usage | (seconds) | Footnotes | |||
Number | Width | gpm | gph | Wash | Rinse | Dwell | ||
Hot Water Single Tank Stationary Rack |
||||||||
45SA-5 | 16x16 | 5.4 | 48.8 | 38 | 12 | 0 | ||
Ensign 40-2 Automatic | 16x16 | 5.4 | 48.8 | 38 | 12 | 0 | ||
CX20 Series |
||||||||
CX20 | 20x20 | 0.6 | 38.4 | 20 | 10 | 25 |
STATIONARY RACK POT, PAN, AND UTENSIL WASHING MACHINES
Final Rinse | ||||||||
(20 psi) | Operating Time | |||||||
Model | Rack Size | Flow | Usage | (seconds) | Footnotes | |||
Number | Width | gpm | gph | Wash | Rinse | Dwell | ||
Single Tank Stationary Rack - Hot Water Sanitizing |
||||||||
CA-3 | 24x28 | 11.2 | 70 | 120 | 15 | 0 | ||
DA-3 | 2*24x28 | 22.4 | 140 | 120 | 15 | 0 |
Number of matching Manufacturers is 1
Number of matching Products is 24
Processing time was 0 seconds