NSF Product and Service Listings

These NSF Official Listings are current as of Sunday, December 22, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/food/Listings.asp?Standard=169&Company=28180&


NSF/ANSI 169
Special Purpose Food Equipment and Devices



 
Digmesa AG 
Keltenstrasse 31
CH-2563 Ipsach 
Switzerland 
41 32 332 7777
Visit this company's website

Facility : Ipsach, Switzerland


EPI Flow Meters[1] [Pb]
  930-0(1)0(2)-(3)
 
[1] (1) 1 digit indicating Housing material:
        2 - PEEK
        5 - PBT 35% GF
    (2) 1 digit indicates connection:
        1 - G1/4" internal thread
        2 - John Guest cartridge only 3/8" (only used with PBT 35% GF)
    (3) A combination of maximum 8 letters/digits indicating:
        01-ZZ - upper part version
        E - EPDM O-ring
        S - Silicon O-ring
        V - Viton O-ring
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

FF Flow Meters[2] [Pb]
  9(1)-(2)(3)(4)-(5)
 
[2] (1) 2 digit indicating with/without foam detection
        34 - without foam detection
        36 - without foam detection
    (Only with (2) connection 8-G5/8" 2x external thread)
        74 - with Pull-up resistor
        81 - with foam detection
    (2) 1 digit indicates connection
        0 - BSF 1/2" (Cola) external thread
        1 - G5/8" 1x external thread / 1x wing nut with internal thread
        2 - G1/4" external thread
        5 - John Guest Cartridges Ø6.0, Ø1/4", Ø8.0, Ø10.0
        6 - John Guest Cartridges 3/8"
        7 - UNF 7/16" (Pepsi) external thread
        8 - G5/8" 2x external thread
    (3) 1 digit indicating Housing material
        5 - PBT 35% GF
    (4) 2 digits indicating Nozzle size
    (5) A combination of maximum 8 letters/digits indicating
        A - with LED Red
        B - Blaschitz
        C - with LED Green
        2 - Impeller with 2 magnets in contact with medium
        4 - Impeller with 4 magnets in contact with medium
        SIG - Foam detection (4 pin connection)
        2SI - Foam detection (4 pin connection) 2 magnets in contact with medium
        4SI - Foam detection (4 pin connection) 4 magnets in contact with medium
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

FH Flat No Lead Brass Flow Meters[3] [4] [Pb]
  93(1)-(2)(3)(4)-(5)
 
[3] (1) 1 digit indicating Upper Part
        A - Upper Part PA-6
        B - Upper Part No Lead Brass
    (2) 1 digit indicating Lower Part
        0 - 2x G1/4" internal thread
        1 - 3x G1/4" internal thread with Bypass
        2 - 2x G1/4" internal thread for ball seal
        4 - 2x G1/8" internal thread
    (3) 1 digit indicating Lower Part Housing material
        6 - No Lead Brass
    (4) 2 digits indicating Nozzle size
    (5) A combination of maximum 8 letters/digits indicating
        01-ZZ - upper part version
            F - PPS nozzle
            V - Viton O-ring
            E - EPDM O-ring
            S - Silicon O-ring
            2 - 2 magnets (non wetted)
            4 - 4 magnets (non wetted)
[4] Acceptable for use in contact with coffee, tea, and water.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

FHK Flow Meters [Pb]
  930-0090
  930-0090-01
  930-0091
  930-0091-01
  930-0094
  937-(1)(2)(3)-(4)[5]
 
[5] (1) 1 digit indicating Lower parts
    (2) 1 digit indicating Housing material
        2 - PPS 40% GF
        5 - Arnite PBT 35% GF
        9 - Grivory
    (3) 2 digits indicating Nozzle size
    (4) A combination of maximum 8 letters/digits indicating
        01-ZZ   - upper part version
        TL01-49 - CombiSensor Digital
        TL51-99 - CombiSensor Analog
        F  - PPS nozzle
        V  - Viton o-ring
        E  - EPDM o-ring
        J  - Stainless steel screw and EPDM o-ring
        N  - Stainless steel screw and Viton O-ring
        S  - Silicon o-ring
        A  - Axel stainless steel 1.4571
        L  - Axel like housing material
        I  - stainless steel screw and silicon O-ring
        D  - Axel stainless steel 1.4571 with two grooves and
             a radius of 0.25, o-ring silicon
        AE - Axle stainless steel 1.4571, EPDM o-ring
        AV - Axle stainless steel 1.4571, Viton O-ring
        2  - 2 magnets (non wetted)
        4  - 4 magnets (non wetted)
        K  - Ceramic bearing
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

Nano Brass Flow Meters[4] [6] [Pb]
  9NB-(1)(2)-(3)
 
[4] Acceptable for use in contact with coffee, tea, and water.
[6] (1) 1 digit indicating connection
    (2) 3 digits indicating Nozzle size
    (3) A combination of maximum 8 letters/digits indicating
        01-ZZ - Versions (Connector, Cable, Cable lengths, Plug, Latex free, etc.)
            A - without Pulse divider
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

Nano Inox Flow Meters[6] [Pb]
  9NI-(1)(2)-(3)
 
[6] (1) 1 digit indicating connection
    (2) 3 digits indicating Nozzle size
    (3) A combination of maximum 8 letters/digits indicating
        01-ZZ - Versions (Connector, Cable, Cable lengths, Plug, Latex free, etc.)
            A - without Pulse divider
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

FHK Flat Flow Meters[7] [Pb]
  936-(1)(2)(3)-(4)
 
[7] (1) 1 digit indicating Lower parts
    (2) 1 digit indicating Housing material
        2 - PPS 40% GF
        5 - Arnite PBT 35% GF
        9 - Grivory
    (3) 2 digits indicating Nozzle size
    (4) A combination of maximum 8 letters/digits indicating
         01-ZZ - upper part version
            F  - PPS nozzle
            V  - Viton o-ring
            E  - EPDM o-ring
            J  - Stainless steel screw and EPDM O-ring
            N  - Stainless steel screw and Viton O-ring
            S  - Silicon o-ring
            A  - Axel stainless steel 1.4571
            L  - Axel like housing material
            I  - stainless steel screw and silicon O-ring
            D  - Axel stainless steel 1.4571 with two grooves and
                 a radius of   0.25, silicon O-ring
            AE - Axle stainless steel 1.4571, EPDM O-ring
            AV - Axle stainless steel 1.4571, Viton O-ring
             2 - 2 magnets (non wetted)
             4 - 4 magnets (non wetted)
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

FHK Type PVDF[8] [Pb]
  930-0027
 
[8] FHK type
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

FHKSC Double Isolation Flow Meters[9] [Pb]
  9(1)-9(2)(3)-(4)
 
[9] (1) 2 digit indicating with/without Pull-up Resistor
        32 - without Pull-up Resistor (open collector)
        74 - with Pull-up Resistor
    (2) 1 digit indicating Housing material
    (3) 2 digits indicating Nozzle size, Fixing art, Hall-IC, Counter
        Nozzle Upper part
    (4) A combination of maximum 8 letters/digits indicating
        01-ZZ - Versions (Connector, Cable, Cable lengths, Plug, Latex free, etc.)
        A  - Silicon O-ring, PP-Turbine, upper part with Steam Protection
        B  - Silicon O-ring, PP-Turbine
        C  - Viton O-ring, PP-Turbine, upper part with Steam Protection
        D  - Viton O-ring, PP-Turbine
        I  - EPDM O-ring, PVDF-Turbine with SmCo magnets (non wetted)
        J  - EPDM O-ring, PVDF-Turbine with SmCo magnets (non wetted),
              upper part with Steam Protection
        L  - Viton O-ring, PVDF-Turbine magnets (non wetted)
        O  - Silicon O-ring, PVDF-Turbine magnets (non wetted),
              upper part with Steam Protection
        U  - packed in an ESD protective bag
        V  - Viton O-ring, PVDF-Turbine
        90 - Montage position 90°
        180 - Montage position 180°
        270 - Montage position 270°
          2 - PVDF Turbine 2 magnets (non wetted)
          4 - PVDF Turbine 4 magnets (non wetted)
         2F - PVDF Turbine with 2 exemptions and 2 magnets (non wetted)
         4F - PVDF Turbine with 2 exemptions and 4 magnets (non wetted)
         2G - PVDF Turbine with 2 exemptions, 0.4mm less height and outer
              diameter Ø26.3mm, 2 magnets (non wetted)
         4G - PVDF Turbine with 2 exemptions, 0.4mm less height and outer
              diameter Ø26.3mm, 4 magnets (non wetted)
          a - yellow product label
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

FHKSK Flow Meters[10] [Pb]
  932-8(1)(2)-(3)
 
[10] (1) 1 digit indicating Housing material
     (2) 2 digits indicating Nozzle size, Fixing art, Hall-IC, Counter Nozzle Upper part
     (3) A combination of maximum 8 letters/digits indicating
         01-ZZ   - Upper part Versions (Connector, Cable, Cable lengths,
                   Plug, Latex  free, etc.)
             A   - Silicon O-ring, PP-Turbine, upper part with Steam Protection
             B   - Silicon O-ring, PP-Turbine
             C   - Viton O-ring, PP-Turbine, upper part with Steam Protection
             D   - Viton O-ring, PP-Turbine
             I   - EPDM O-ring, PVDF-Turbine with SmCo magnets (non wetted)
             J   - EPDM O-ring, PVDF-Turbine with SmCo magnets (non wetted),
                   upper part  with Steam Protection
             L   - Viton O-ring, PVDF-Turbine magnets (non wetted)
             O   - Silicon O-ring, PVDF-Turbine magnets (non wetted),
                   upper part with Steam Protection
             U   - packed in an ESD protective bag
             V   - Viton O-ring, PVDF-Turbine
             90  - Montage position 90°
             180 - Montage position 180°
             270 - Montage position 270°
             2   - PVDF Turbine 2 magnets (non wetted)
             4   - PVDF Turbine 4 magnets (non wetted)
             2F  - PVDF Turbine with 2 exemptions and 2 magnets (non wetted)
             4F  - PVDF Turbine with 2 exemptions and 4 magnets (non wetted)
             2G  - PVDF Turbine with 2 exemptions, 0.4mm less height and outer
                   diameter Ø26.3mm, 2 magnets (non wetted)
             4G  - PVDF Turbine with 2 exemptions, 0.4mm less height and outer
                   diameter Ø26.3mm, 4 magnets (non wetted)
              a  - yellow product label
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

FHKU Flow Meters [Pb]
  930-0035
  938-(1)(2)(3)-(4)[11]
 
[11] (1) 1 digit indicating Lower parts
     (2) 1 digit indicating Housing material 
         2 - PPS 40% GF
         5 - Arnite PBT 35% GF
         9 - Grivory
     (3) 2 digits indicating Nozzle size
     (4) A combination of maximum 8 letters/digits indicating
           01-ZZ - upper part version
         TL01-49 - CombiSensor Digital
        	TL51-99 - CombiSensor Analog
       	F  - PPS nozzle
        	V  - Viton o-ring
        	E  - EPDM o-ring
         J  - Stainless steel screw and EPDM o-ring
         N  - Stainless steel screw and Viton o-ring
        	S  - Silicon o-ring
        	A  - Axel stainless steel 1.4571
        	L  - Axel like housing material
        	I  - stainless steel screw and silicon o-ring
         D  - Axel stainless steel 1.4571 with two grooves and a radius of 0.25,
              o-ring silicon
         AE - Axle stainless steel 1.4571, EPDM o-ring
         AV - Axle stainless steel 1.4571, Viton o-ring
        	2  - 2 magnets (non wetted)
        	4  - 4 magnets (non wetted)
         K  - Ceramic bearing
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

FHKU Flat Flow Meters[12] [Pb]
  939-(1)(2)(3)-(4)
 
[12] (1) 1 digit indicating Lower parts
     (2) 1 digit indicating Housing material
         2 - PPS 40% GF
         5 - Arnite PBT 35% GF
         9 - Grivory
     (3) 2 digits indicating Nozzle size
     (4) A combination of maximum 8 letters/digits indicating
         01-ZZ - upper part version
          F    - PPS nozzle
          V    - Viton O-ring
          E    - EPDM O-ring
          J    - Stainless steel screw and EPDM O-ring
          N    - Stainless steel screw and Viton O-ring
          S    - Silicon O-ring
          A    - Axel stainless steel 1.4571
          L    - Axel like housing material
          I    - stainless steel screw and silicon O-ring
          D    - Axel stainless steel 1.4571 with two grooves and
                 a radius of 0.25,  silicon O-ring
          AE   - Axle stainless steel 1.4571, EPDM O-ring
          AV   - Axle stainless steel 1.4571, Viton O-ring
          2    - 2 magnets (non wetted)
          4    - 4 magnets (non wetted)
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

FM Flow Meters[13] [Pb]
  935-(1)(2)00-(3)
 
[13] (1) 1 digit indicating electrical connections
         1 - 3 pin 
         2 - 3x AMP 6.3/2.8 mm
     (2) 1 digit indicating Housing material
         5 - Arnite PBT 35% GF
     (3) A combination of maximum 8 letters/digits indicating
         01-ZZ - upper part version
          PNP  - PNP Signal
          DOP  - Double Hall-IC
            2  - 2 magnets
            4  - 4 magnets
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

FM 15 Flow Meters[14] [Pb]
  935-3901-(1)
 
[14] (1) A combination of maximum 8 letters/digits indicating
         01-ZZ - upper part version
           PNP - PNP Signal
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

Nano Flow Meters[15] [Pb]
  93N-(1)(2)(3)-(4)
 
[15] (1) 1 digit indicating Hose nipple diameter
     (2) 1 digit indicating Housing material
         2 - Tube and Turbine cage PP, Turbine PVDF
     (3) 2 digits indicating Nozzle size
     (4) A combination of maximum 8 letters/digits indicating
         01-ZZ - Versions (with/without Connector, Cable, Cable lengths,
                 Rack, rotated 180°, Latex free, with specific testing, etc.)
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


Number of matching Manufacturers is 1
Number of matching Products is 21
Processing time was 0 seconds