NSF Product and Service Listings
These NSF Official Listings are current as of Tuesday, February 10, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/food/Listings.asp?Standard=007&Company=29010&
NSF/ANSI 7
Commercial Refrigerators and Storage Freezers
Commercial Refrigerators and Storage Freezers
| Trenton Refrigeration Products | |
| A Division of National Refrigeration & | |
| Air Conditioning Products, Inc. | |
| 539 Dunksferry Road | |
| Bensalem, PA 19020-5908 | |
| United States | |
| 215-244-1400 |
Facility : Kilgore, TX
|
COMPONENTS: |
|
|
Low Profile Unit Cooler [7] |
|
| TLP(1)(2)(3)(4)(5)(6)(7)[1] | |
| TPLP(1)(2)(3)(4)(5)(6)(7)(8)[2] | |
[1] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
1000
(3) Evaporator temperature range: L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7
(6) Design version: engineering revision
(7) Optional suffix, does not affect design
[2] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x 1000
(3) Evaporator temperature range: L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7
(6) Design version: engineering revision
(7) Optional suffix for internal usage
(8) Optional suffix, does not affect design
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
|
Low Velocity Walk-In Unit Cooler [7] |
|
| TLV (1)(2)(3)(4)(5) Series[4] [5] | |
| TLV060[4] [5] | |
| TLV090[4] [5] | |
| TLV120[4] [5] | |
| TLV150[4] [5] | |
| TLV180[4] [5] | |
| TLV220[4] [5] | |
| TLV270[4] [5] | |
| TLV300[4] [5] | |
| TLV340[4] [5] | |
| TLV370[4] [5] | |
| TTM(1)(2)(3)(4)(5)(6) Series[3] | |
[3] (1) 3 digit number from 009-531, indicating nominal capacity and number of Fans
(2) Evap temperature range: L, M, V, or W
(3) Defrost type: A, E, G, H, R, or T
(4) Unit electrical designation: S2, S4, T3,T4
(5) Design version
(6) Optional suffix, does not affect design
[4] TLV units Certified with the following suffix designations
(1) Fluid designations: W (if applicable) - water/glycol
(2) Defrost type: AD, ED, HE, RE or TE
(3) Voltage: S1 , S2, S5 or S6
(4) Design version
(5) Optional suffix, does not affect design
[5] TLV models may contain a four digit numeric suffix to indicate customer required
options
These options may not include changes to the unit exterior or mounting.
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
|
Medium Profile Unit Cooler [7] |
|
| TMP(1)(2)(3)(4)(5)(6)(7)[6] | |
[6] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x 1000
(3) Evap temperature range: L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S2, S4, S5, T3, T4, or T5
(6) Design version: engineering revision
(7) Optional suffix for internal usage
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
Facility : Longview, TX
|
COMPONENTS: |
|
|
Low Profile Unit Cooler [7] |
|
| TLP(1)(2)(3)(4)(5)(6)(7)[1] | |
| TPLP(1)(2)(3)(4)(5)(6)(7)(8)[2] | |
[1] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
1000
(3) Evaporator temperature range: L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7
(6) Design version: engineering revision.
(7) Optional suffix, does not affect design
[2] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
1000
(3) Evaporator temperature range: L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7
(6) Design version: engineering revision
(7) Optional suffix for internal usage
(8) Optional suffix, does not affect design
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
|
Low Velocity Walk-In Unit Cooler [7] |
|
| TLV (1)(2)(3)(4)(5) Series[4] [5] | |
| TLV060[4] [5] | |
| TLV090[4] [5] | |
| TLV120[4] [5] | |
| TLV150[4] [5] | |
| TLV180[4] [5] | |
| TLV220[4] [5] | |
| TLV270[4] [5] | |
| TLV300[4] [5] | |
| TLV340[4] [5] | |
| TLV370[4] [5] | |
| TTM(1)(2)(3)(4)(5)(6) Series[3] | |
[3] (1) 3 digit number from 009-531, indicating nominal capacity and number of Fans
(2) Evap temperature range: L, M, V, or W
(3) Defrost type: A, E, G, H, R, or T
(4) Unit electrical designation: S2, S4, T3,T4
(5) Design version
(6) Optional suffix, does not affect design
[4] TLV units Certified with the following suffix designations
(1) Fluid designations: W (if applicable) - water/glycol
(2) Defrost type: AD, ED, HE, RE or TE
(3) Voltage: S1 , S2, S5 or S6
(4) Design version
(5) Optional suffix, does not affect design
[5] TLV models may contain a four digit numeric suffix to indicate customer required
options
These options may not include changes to the unit exterior or mounting.
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
|
Medium Profile Unit Cooler [7] |
|
| TMP(1)(2)(3)(4)(5)(6)(7)[6] | |
[6] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
1000
(3) Evap temperature range: L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S2, S4, S5, T3, T4, or T5
(6) Design version: engineering revision
(7) Optional suffix for internal usage
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
Facility : Brantford, Ontario, Canada
|
COMPONENTS: |
|
|
Extended Profile Unit Cooler [7] |
|
| TEP(2)(3)(4)(5)(6)(7)[1] | |
[1] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-135 x
1000
(3) Evap temperature range: H, L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S2, S4, S5, T3, T4, or T5
(6) Design version: engineering revision
(7) Optional suffix for internal usage
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
|
Low Profile Unit Cooler [7] |
|
| TLP(1)(2)(3)(4)(5)(6)(7)[2] | |
| TPLP(1)(2)(3)(4)(5)(6)(7)(8)[3] | |
[2] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
1000
(3) Evaporator temperature range: L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7
(6) Design version: engineering revision
(7) Optional suffix, does not affect design
[3] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
1000
(3) Evaporator temperature range: L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7
(6) Design version: engineering revision
(7) Optional suffix for internal usage
(8) Optional suffix, does not affect design
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
|
Low Velocity Walk-in Unit Coolers [7] |
|
| TLV (1)(2)(3)(4)(5) Series[5] [6] | |
| TLV060[5] [6] | |
| TLV090[5] [6] | |
| TLV120[5] [6] | |
| TLV150[5] [6] | |
| TLV180[5] [6] | |
| TLV220[5] [6] | |
| TLV270[5] [6] | |
| TLV300[5] [6] | |
| TLV340[5] [6] | |
| TLV370[5] [6] | |
| TTM(1)(2)(3)(4)(5)(6) Series[4] | |
[4] (1) 3 digit number from 009-531, indicating nominal capacity and number of Fans
(2) Evap temperature range: L, M, V, or W
(3) Defrost type: A, E, G, H, R, or T
(4) Unit electrical designation: S2, S4, T3,T4
(5) Design version
(6) Optional suffix, does not affect design
[5] TLV units Certified with the following suffix designations
(1) Fluid designations: W (if applicable) - water/glycol
(2) Defrost type: AD, ED, HE, RE or TE
(3) Voltage: S1 , S2, S5 or S6
(4) Design version
(5) Optional suffix, does not affect design
[6] TLV models may contain a four digit numeric suffix to indicate customer required
options
These options may not include changes to the unit exterior or mounting.
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
|
Medium Profile Unit Cooler [7] |
|
| TMP(1)(2)(3)(4)(5)(6)(7)[1] | |
[1] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-135 x
1000
(3) Evap temperature range: H, L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S2, S4, S5, T3, T4, or T5
(6) Design version: engineering revision
(7) Optional suffix for internal usage
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
Number of matching Manufacturers is 1
Number of matching Products is 46
Processing time was 0 seconds