NSF Product and Service Listings

These NSF Official Listings are current as of Tuesday, February 10, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/food/Listings.asp?Standard=007&Company=29010&


NSF/ANSI 7
Commercial Refrigerators and Storage Freezers



 
Trenton Refrigeration Products 
A Division of National Refrigeration &
Air Conditioning Products, Inc. 
539 Dunksferry Road 
Bensalem, PA 19020-5908 
United States 
215-244-1400

Facility : Kilgore, TX


COMPONENTS:

Low Profile Unit Cooler [7]
  TLP(1)(2)(3)(4)(5)(6)(7)[1]
  TPLP(1)(2)(3)(4)(5)(6)(7)(8)[2]
 
[1] (1) Number of fans	
    (2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
    1000	
    (3) Evaporator temperature range: L, M, V, or W	
    (4) Defrost type: A, E, G, H, R, or T	
    (5)  Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7	
    (6) Design version: engineering revision	
    (7) Optional suffix, does not affect design
[2] (1) Number of fans
    (2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x 1000
    (3) Evaporator temperature range: L, M, V, or W
    (4) Defrost type: A, E, G, H, R, or T
    (5)  Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7
    (6) Design version: engineering revision
    (7) Optional suffix for internal usage
    (8) Optional suffix, does not affect design
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
    installed in the field

Low Velocity Walk-In Unit Cooler [7]
  TLV (1)(2)(3)(4)(5) Series[4] [5]
  TLV060[4] [5]
  TLV090[4] [5]
  TLV120[4] [5]
  TLV150[4] [5]
  TLV180[4] [5]
  TLV220[4] [5]
  TLV270[4] [5]
  TLV300[4] [5]
  TLV340[4] [5]
  TLV370[4] [5]
  TTM(1)(2)(3)(4)(5)(6) Series[3]
 
[3] (1) 3 digit number from 009-531, indicating nominal capacity and number of Fans
    (2) Evap temperature range: L, M, V, or W
    (3) Defrost type: A, E, G, H, R, or T
    (4) Unit electrical designation: S2, S4, T3,T4
    (5) Design version
    (6) Optional suffix, does not affect design
[4] TLV units Certified with the following suffix designations	
    (1) Fluid designations: W (if applicable) - water/glycol	
    (2) Defrost type: AD, ED, HE,  RE or TE	
    (3) Voltage: S1 , S2,  S5 or S6	
    (4) Design version	
    (5) Optional suffix, does not affect design 
[5] TLV models may contain a four digit numeric suffix to indicate customer required
    options	
    These options may not include changes to the unit exterior or mounting.
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
    installed in the field

Medium Profile Unit Cooler [7]
  TMP(1)(2)(3)(4)(5)(6)(7)[6]
 
[6] (1) Number of fans
    (2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x 1000
    (3) Evap temperature range: L, M, V, or W
    (4) Defrost type: A, E, G, H, R, or T
    (5) Unit electrical designation: S2, S4, S5, T3, T4, or T5
    (6) Design version: engineering revision
    (7) Optional suffix for internal usage
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
    installed in the field


Facility : Longview, TX


COMPONENTS:

Low Profile Unit Cooler [7]
  TLP(1)(2)(3)(4)(5)(6)(7)[1]
  TPLP(1)(2)(3)(4)(5)(6)(7)(8)[2]
 
[1] (1) Number of fans	
    (2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
    1000	
    (3) Evaporator temperature range: L, M, V, or W	
    (4) Defrost type: A, E, G, H, R, or T	
    (5)  Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7	
    (6) Design version: engineering revision.
    (7) Optional suffix, does not affect design
[2] (1) Number of fans	
    (2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
    1000	
    (3) Evaporator temperature range: L, M, V, or W	
    (4) Defrost type: A, E, G, H, R, or T	
    (5)  Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7	
    (6) Design version: engineering revision	
    (7) Optional suffix for internal usage
    (8) Optional suffix, does not affect design
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
    installed in the field

Low Velocity Walk-In Unit Cooler [7]
  TLV (1)(2)(3)(4)(5) Series[4] [5]
  TLV060[4] [5]
  TLV090[4] [5]
  TLV120[4] [5]
  TLV150[4] [5]
  TLV180[4] [5]
  TLV220[4] [5]
  TLV270[4] [5]
  TLV300[4] [5]
  TLV340[4] [5]
  TLV370[4] [5]
  TTM(1)(2)(3)(4)(5)(6) Series[3]
 
[3] (1) 3 digit number from 009-531, indicating nominal capacity and number of Fans	
    (2) Evap temperature range: L, M, V, or W	
    (3) Defrost type: A, E, G, H, R, or T	
    (4) Unit electrical designation: S2, S4, T3,T4	
    (5) Design version	
    (6) Optional suffix, does not affect design
[4] TLV units Certified with the following suffix designations	
    (1) Fluid designations: W (if applicable) - water/glycol	
    (2) Defrost type: AD, ED, HE,  RE or TE	
    (3) Voltage: S1 , S2,  S5 or S6	
    (4) Design version
    (5) Optional suffix, does not affect design
[5] TLV models may contain a four digit numeric suffix to indicate customer required
    options	
    These options may not include changes to the unit exterior or mounting.
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
    installed in the field

Medium Profile Unit Cooler [7]
  TMP(1)(2)(3)(4)(5)(6)(7)[6]
 
[6] (1) Number of fans	
    (2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
    1000	
    (3) Evap temperature range: L, M, V, or W
    (4) Defrost type: A, E, G, H, R, or T	
    (5) Unit electrical designation: S2, S4, S5, T3, T4, or T5	
    (6) Design version: engineering revision	
    (7) Optional suffix for internal usage
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
    installed in the field


Facility : Brantford, Ontario, Canada


COMPONENTS:

Extended Profile Unit Cooler [7]
  TEP(2)(3)(4)(5)(6)(7)[1]
 
[1] (1) Number of fans	
    (2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-135 x
    1000	
    (3) Evap temperature range: H, L, M, V, or W	
    (4) Defrost type: A, E, G, H, R, or T	
    (5) Unit electrical designation: S2, S4, S5, T3, T4, or T5	
    (6) Design version: engineering revision	
    (7) Optional suffix for internal usage
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
    installed in the field

Low Profile Unit Cooler [7]
  TLP(1)(2)(3)(4)(5)(6)(7)[2]
  TPLP(1)(2)(3)(4)(5)(6)(7)(8)[3]
 
[2] (1) Number of fans	
    (2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
    1000	
    (3) Evaporator temperature range: L, M, V, or W	
    (4) Defrost type: A, E, G, H, R, or T	
    (5)  Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7	
    (6) Design version: engineering revision
    (7) Optional suffix, does not affect design
[3] (1) Number of fans	
    (2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
    1000	
    (3) Evaporator temperature range: L, M, V, or W	
    (4) Defrost type: A, E, G, H, R, or T	
    (5)  Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7	
    (6) Design version: engineering revision	
    (7) Optional suffix for internal usage
    (8) Optional suffix, does not affect design
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
    installed in the field

Low Velocity Walk-in Unit Coolers [7]
  TLV (1)(2)(3)(4)(5) Series[5] [6]
  TLV060[5] [6]
  TLV090[5] [6]
  TLV120[5] [6]
  TLV150[5] [6]
  TLV180[5] [6]
  TLV220[5] [6]
  TLV270[5] [6]
  TLV300[5] [6]
  TLV340[5] [6]
  TLV370[5] [6]
  TTM(1)(2)(3)(4)(5)(6) Series[4]
 
[4] (1) 3 digit number from 009-531, indicating nominal capacity and number of Fans	
    (2) Evap temperature range: L, M, V, or W	
    (3) Defrost type: A, E, G, H, R, or T	
    (4) Unit electrical designation: S2, S4, T3,T4	
    (5) Design version	
    (6) Optional suffix, does not affect design
[5] TLV units Certified with the following suffix designations	
    (1) Fluid designations: W (if applicable) - water/glycol	
    (2) Defrost type: AD, ED, HE,  RE or TE	
    (3) Voltage: S1 , S2,  S5 or S6	
    (4) Design version
    (5) Optional suffix, does not affect design
[6] TLV models may contain a four digit numeric suffix to indicate customer required
    options	
    These options may not include changes to the unit exterior or mounting.
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
    installed in the field

Medium Profile Unit Cooler [7]
  TMP(1)(2)(3)(4)(5)(6)(7)[1]
 
[1] (1) Number of fans	
    (2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-135 x
    1000	
    (3) Evap temperature range: H, L, M, V, or W	
    (4) Defrost type: A, E, G, H, R, or T	
    (5) Unit electrical designation: S2, S4, S5, T3, T4, or T5	
    (6) Design version: engineering revision	
    (7) Optional suffix for internal usage
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
    installed in the field


Number of matching Manufacturers is 1
Number of matching Products is 46
Processing time was 0 seconds