NSF Product and Service Listings
These NSF Official Listings are current as of Friday, January 30, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/food/Listings.asp?Standard=169&Company=3G900&
NSF/ANSI 169
Special Purpose Food Equipment and Devices
Special Purpose Food Equipment and Devices
| CEME S.p.A. | ![]() |
| Viale dell'Industria, 5 | |
| 27020 Trivolzio (PV) | |
| Italy | |
| 39 03 821 8051 | |
| Visit this company's website |
Facility : Guangdong Province, China
|
Fitting[1] [Pb] |
|
| Pipetta | |
| Raccordino 90º[2] | |
| Raccordo Bar[3] | |
[1] Models produced at this facility will bear a 'c' on the label.
[2] Not acceptable for use in contact with alcoholic beverages.
[3] Only acceptable for use in contact with coffee, tea, and potable water.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Valve (Valvola)[1] [2] [Pb] |
|
| S1[3] | |
| S11[3] | |
| S2[4] | |
| S22[4] | |
| S3 | |
| S3BP | |
| S3HP | |
| S3HP/R | |
| S4 | |
[1] Models produced at this facility will bear a 'c' on the label.
[2] Not acceptable for use in contact with alcoholic beverages.
[3] Only acceptable for use in contact with coffee, tea, and potable water.
[4] Only acceptable for use in contact with non-carbonated, potable water with a maximum
contact temperature of 82°C.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Water Oscillating Pump - E Range[1] [2] |
|
| EAP4[Pb] | |
| EAP5[Pb] | |
| EAP7[Pb] | |
| EAX4[5] | |
| EAX5[5] | |
| EFP4[Pb] | |
| EFP5[Pb] | |
| EFP7[Pb] | |
| EFX4[5] | |
| EFX5[5] | |
| EK[Pb] | |
| EK2[Pb] | |
| EK2GW[Pb] | |
| EN4[Pb] | |
| EN4FM[5] | |
| EN4FMCA[5] | |
| EP4[Pb] | |
| EP45[Pb] | |
| EP4FM[Pb] | |
| EP4FMGW[Pb] | |
| EP4GW[Pb] | |
| EP4R[Pb] | |
| EP4RGW[Pb] | |
| EP5[Pb] | |
| EP5BN[Pb] | |
| EP5FM[Pb] | |
| EP5FM/SP[Pb] | |
| EP5FMGW[Pb] | |
| EP5FMGW/CA[Pb] | |
| EP5FMGW/SP[Pb] | |
| EP5FMGW/SPCA[Pb] | |
| EP5GW[Pb] | |
| EP5R[Pb] | |
| EP7[Pb] | |
| EP77[Pb] | |
| EP77GW[Pb] | |
| EP7GW[Pb] | |
| EP8[Pb] | |
| EP8GW[Pb] | |
| EP8LT[Pb] | |
| EP8LTGW[Pb] | |
| EP8R[Pb] | |
| EP8RGW[Pb] | |
| EX4[3] [5] | |
| EX4FM[3] [5] | |
| EX4FMGW[3] [5] | |
| EX4GW[3] [5] | |
| EX4R[3] [5] | |
| EX4RGW[3] [5] | |
| EX5[3] [5] | |
| EX5FM[3] [5] | |
| EX5FMGW[3] [5] | |
| EX5GW[3] [5] | |
[1] Models produced at this facility will bear a 'c' on the label.
[2] Not acceptable for use in contact with alcoholic beverages.
[3] Only acceptable for use in contact with coffee, tea, and potable water.
[5] Certified for use as part of a food equipment item with a resulting overall weighted
average lead content of = 0.25% in the water contact portion of the equipment.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Water Oscillating Pump - HF[1] [2] [Pb] |
|
| HF | |
| HF/S | |
| HF2 | |
| HF2S | |
[1] Models produced at this facility will bear a 'c' on the label.
[2] Not acceptable for use in contact with alcoholic beverages.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Water Oscillating Pump - NME Range[1] [Pb] |
|
| NME1[2] | |
| NME1C[2] | |
| NME1S[2] | |
| NME2[2] | |
| NME3[2] | |
| NME3S[2] | |
| NME4[2] | |
| NMECC | |
| NMEHP1[2] | |
| NMEHP1/S[2] | |
| NMEHP2[2] | |
| NMEHP2/S[2] | |
| NMEHP3[2] | |
| NMEHP3/S[2] | |
| NMEHP4[2] | |
| NMEHP4/S[2] | |
[1] Models produced at this facility will bear a 'c' on the label.
[2] Not acceptable for use in contact with alcoholic beverages.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
COMPONENTS: |
|
|
Electrovalves with Nickel-Plated Brass Bodies[6] [Pb] |
|
| 52(1)(2)(3)N(4)(5) | |
| 53(1)(2)(3)N(4)(5) | |
[6] (1) Two digits for the hydraulic connection.
(2) Two digits for seal material.
(3) Three digit for hole diameter in mm (with or without comma, ie 2, 0 or 20 is 2mm).
(4) U, L and Z only differ in the body material; U and L are made of brass and Z is made
of SS.
(5) Five digits for special executions.
(6) Three digits for coil code.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Electrovalves with Plastic Bodies[6] [Pb] |
|
| V3(1)(2)(3)P(4)(5)[7] | |
| V7(1)(2)(3)P(4)(5)[7] | |
| VD(1)(2)(3)P(4)(5) | |
[6] (1) Two digits for the hydraulic connection.
(2) Two digits for seal material.
(3) Three digit for hole diameter in mm (with or without comma, ie 2, 0 or 20 is 2mm).
(4) U, L and Z only differ in the body material; U and L are made of brass and Z is made
of SS.
(5) Five digits for special executions.
(6) Three digits for coil code.
[7] Only acceptable for use in contact with non-carbonated potable water under constant
service pressure, with a maximum contact temperature of 82°C.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Electrovalves with Tin-Nickel Plated Bodies[5] [8] |
|
| 57(1)(2)(3)T(4)(5) | |
| 66(1)(2)(3)T(4)(5) | |
| 83(1)(2)(3)T(4)(5) | |
[5] Certified for use as part of a food equipment item with a resulting overall weighted
average lead content of = 0.25% in the water contact portion of the equipment.
[8] (1) Two digits for hydraulic connection.
(2) Two digits for seal material
(3) Three digits for hole diameter in mm (with or without comma, ie
2,0 or 20 is 2mm)
(4) Two possible digits for special executions.
(5) Three digits for coil code.
|
|
|
Flow Meter[11] [14] [Pb] |
|
| AB32 | |
| AD72 | |
| AH97 | |
| AK66 | |
[11] Approved for water contact only.
[14] With the following sizes of orifices; 1.0 mm - 4.0mm.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Low Lead Brass and Stainless Steel Solenoid Valves[6] [Pb] |
|
| 52(1)(2)(3)(4)(5)(6) | |
| 53(1)(2)(3)(4)(5)(6) | |
| 62(1)(2)(3)(4)(5)(6) | |
[6] (1) Two digits for the hydraulic connection.
(2) Two digits for seal material.
(3) Three digit for hole diameter in mm (with or without comma, ie 2, 0 or 20 is 2mm).
(4) U, L and Z only differ in the body material; U and L are made of brass and Z is made
of SS.
(5) Five digits for special executions.
(6) Three digits for coil code.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
One Way Valve - C Series[9] [Pb] |
|
| C1NA75 | |
| C1NAI | |
| C1NAV | |
| C3NAI | |
[9] (1) One character for spring load.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Solenoid Pump [Pb] |
|
| Phoenix(1)[11] [12] [13] | |
[11] Approved for water contact only.
[12] (1) Two digit suffix indicating plunger size.
[13] May be followed by suffix 'N' representing customer specific request.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Solenoid Water Valve with Plastic Body [Pb] |
|
| W(1)(2)(3)(4)(5)(6)(7)(8)[10] | |
| W(1)(2)(3)(4)(5)(6)3(8)[4] [10] | |
[4] Only acceptable for use in contact with non-carbonated, potable water with a maximum
contact temperature of 82°C.
[10] (1) One digit indicating Inlet type
(2) One digit indicating Outlet type
(3) Two digits indicating DN measurement
(4) One Digit: 0 or 1
(5) 1 Digit indicating the capacity of the Flow Restrictor
(6) 1 Digit indicating the presence of a Flow regulator
(7) One digit indicating Filter type, except "3"
(8) One digit indicating the customization
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Solenoid Valve[Pb] |
|
|
AL26 series[15] [16] |
|
| AL26-(15)(16)-(17)-(18) | |
[15] (1) One character indicating body material.
(2) Type of body connection(1,A,B,D,F,G).
(3) Type of fix core, one or two characters.
(4) One character indicating copper ring.
(5) One character indicating seal material.
(6) Diameter of orifice(1.0 mm, 1.2 mm, 1.5 mm, 1.7 mm, 2.0 mm, 2.3 mm, 2.5 mm).
(7) Internal code.
(8) Fluidific function.
(9) Elements number.
(10) Elements type, one to six characters.
(11) Voltage range, two or three characters.
(12) Coil type, one to four characters.
(13) Nature of supply,one character.
(15) One character indicating DC voltage or AC voltage.
(16) Three characters indicating voltage value.
(17) Two to four characters indicating internal code.
(18) One character indicating special requirement of customer or no character.
[16] Acceptable for contact with non-carbonated potable water only.
|
|
|
BV Series[15] [17] |
|
| BV(9)(10)(1)-(7) | |
[15] (1) One character indicating body material.
(2) Type of body connection(1,A,B,D,F,G).
(3) Type of fix core, one or two characters.
(4) One character indicating copper ring.
(5) One character indicating seal material.
(6) Diameter of orifice(1.0 mm, 1.2 mm, 1.5 mm, 1.7 mm, 2.0 mm, 2.3 mm, 2.5 mm).
(7) Internal code.
(8) Fluidific function.
(9) Elements number.
(10) Elements type, one to six characters.
(11) Voltage range, two or three characters.
(12) Coil type, one to four characters.
(13) Nature of supply,one character.
(15) One character indicating DC voltage or AC voltage.
(16) Three characters indicating voltage value.
(17) Two to four characters indicating internal code.
(18) One character indicating special requirement of customer or no character.
[17] Acceptable for contact with non-carbonated potable water and steam.
|
|
|
D21Series[15] [17] |
|
| D21J(1)(2)(3)(4)(5)(6)-(11)(12)-(7) | |
| D21J(1)(2)(3)(4)(5)(6)-(7)-(12) | |
[15] (1) One character indicating body material.
(2) Type of body connection(1,A,B,D,F,G).
(3) Type of fix core, one or two characters.
(4) One character indicating copper ring.
(5) One character indicating seal material.
(6) Diameter of orifice(1.0 mm, 1.2 mm, 1.5 mm, 1.7 mm, 2.0 mm, 2.3 mm, 2.5 mm).
(7) Internal code.
(8) Fluidific function.
(9) Elements number.
(10) Elements type, one to six characters.
(11) Voltage range, two or three characters.
(12) Coil type, one to four characters.
(13) Nature of supply,one character.
(15) One character indicating DC voltage or AC voltage.
(16) Three characters indicating voltage value.
(17) Two to four characters indicating internal code.
(18) One character indicating special requirement of customer or no character.
[17] Acceptable for contact with non-carbonated potable water and steam.
|
|
|
D31Series[15] [17] |
|
| 5696(3)(4)(5)(6)-(12) | |
| D31J(1)(2)(3)(4)(5)(6)-(11)(12)-(7) | |
| D31J(1)(2)(3)(4)(5)(6)-(7)-(12) | |
[15] (1) One character indicating body material.
(2) Type of body connection(1,A,B,D,F,G).
(3) Type of fix core, one or two characters.
(4) One character indicating copper ring.
(5) One character indicating seal material.
(6) Diameter of orifice(1.0 mm, 1.2 mm, 1.5 mm, 1.7 mm, 2.0 mm, 2.3 mm, 2.5 mm).
(7) Internal code.
(8) Fluidific function.
(9) Elements number.
(10) Elements type, one to six characters.
(11) Voltage range, two or three characters.
(12) Coil type, one to four characters.
(13) Nature of supply,one character.
(15) One character indicating DC voltage or AC voltage.
(16) Three characters indicating voltage value.
(17) Two to four characters indicating internal code.
(18) One character indicating special requirement of customer or no character.
[17] Acceptable for contact with non-carbonated potable water and steam.
|
|
|
Flow Meter [Pb] |
|
| F(1)(2)(3)(4)(5)(6)(7)[11] [18] | |
[11] Approved for water contact only.
[18] (1) 2 Digit indicating body material & inlet and outlet:
22= Plastic -- 1/4-1/4 GAS Thread
32= SS -- 1/4-1/4 GAS Thread
42= Brass -- 1/4-1/4 GAS Thread
52= Plastic -- 1/8-1/8 GAS Thread
62= SS -- 1/8-1/8 GAS Thread
AA= SS -- 6mm-6mm Push Fit
BB=SS -- 8mm-8mm Push Fit
CC=Plastic -- 6mm-6mm Push Fit
DD=Plastic -- 8mm-8mm Push Fit
(2) 2 Digits indicating material of pignon:
10=plastic, 11=SS
(3) 3 Digits indicating diameter of orifize
(4) 1 Digit indicating the number of magnets
(5) 1 Digit indicating material of cover:
0=plastic, 1=SS
(6) 1 Digit indicating type of electrical connection
(7) 1 Digit indicating type of sensor
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
IL Series[15] [17] |
|
| 2(8)IL(1)(2)(3)(6)(11)(13) | |
| 2(8)IL(1)(2)(3)(6)(11)(13)-(7) | |
[15] (1) One character indicating body material.
(2) Type of body connection(1,A,B,D,F,G).
(3) Type of fix core, one or two characters.
(4) One character indicating copper ring.
(5) One character indicating seal material.
(6) Diameter of orifice(1.0 mm, 1.2 mm, 1.5 mm, 1.7 mm, 2.0 mm, 2.3 mm, 2.5 mm).
(7) Internal code.
(8) Fluidific function.
(9) Elements number.
(10) Elements type, one to six characters.
(11) Voltage range, two or three characters.
(12) Coil type, one to four characters.
(13) Nature of supply,one character.
(15) One character indicating DC voltage or AC voltage.
(16) Three characters indicating voltage value.
(17) Two to four characters indicating internal code.
(18) One character indicating special requirement of customer or no character.
[17] Acceptable for contact with non-carbonated potable water and steam.
|
|
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
Facility : Riau, Indonesia
|
Electrovalves with Plastic Bodies[1] [2] [Pb] |
|
| V3(1)(2)(3)P(4)(5) | |
| V7(1)(2)(3)P(4)(5) | |
| VD(1)(2)(3)P(4)(5) | |
[1] (1) Two digits for the hydraulic connection.
(2) Two digits for seal material
(3) Hole diamater in mm (with or without comma, ie 2,0 or 20 is 2mm)
(4) Five digits for special executions.
(5) Three digits for coil code
[2] Only acceptable for use in contact with non-carbonated potable water under constant
service pressure, with a maximum contact temperature of 82°C.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
COMPONENTS: |
|
|
Flow Meter[3] [4] [Pb] |
|
| F(1)(2)(3)(4)(5)(6)(7) | |
[3] (1) 2 Digit indicating body material & inlet and outlet:
22 - Plastic -- 1/4-1/4 GAS Thread
32 - SS -- 1/4-1/4 GAS Thread
42 - Brass -- 1/4-1/4 GAS Thread
52 - Plastic -- 1/8-1/8 GAS Thread
62 - SS -- 1/8-1/8 GAS Thread
AA - SS -- 6mm-6mm Push Fit
BB - SS -- 8mm-8mm Push Fit
CC - Plastic -- 6mm-6mm Push Fit
DD - Plastic -- 8mm-8mm Push Fit
(2) 2 Digits indicating material of pignon:
10 - plastic, 11 - SS
(3) 3 Digits indicating diameter of orifize
(4) 1 Digit indicating the number of magnets
(5) 1 Digit indicating material of cover:
0 - plastic, 1 - SS
(6) 1 Digit indicating type of electrical connection
(7) 1 Digit indicating type of sensor
[4] Approved for water contact only.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Water Oscillating Pump - E-Range[5] |
|
| EAP4[Pb] | |
| EAP5[Pb] | |
| EAP7[Pb] | |
| EAX4[6] [7] | |
| EAX5[6] [7] | |
| EFP4[Pb] | |
| EFP5[Pb] | |
| EFP7[Pb] | |
| EFX4[6] [7] | |
| EFX5[6] [7] | |
| EK[Pb] | |
| EK2[Pb] | |
| EK2GW[Pb] | |
| EN4[Pb] | |
| EN4[Pb] | |
| EN4FM[7] | |
| EN4FMCA[7] | |
| EP4[Pb] | |
| EP45[Pb] | |
| EP45[Pb] | |
| EP4FM[Pb] | |
| EP4FMGW[Pb] | |
| EP4GW[Pb] | |
| EP4R[Pb] | |
| EP4RGW[Pb] | |
| EP5[Pb] | |
| EP5 GW[Pb] | |
| EP5BN[Pb] | |
| EP5BN[Pb] | |
| EP5FM[Pb] | |
| EP5FM/SP[Pb] | |
| EP5FMGW[Pb] | |
| EP5FMGW/CA[Pb] | |
| EP5FMGW/SP[Pb] | |
| EP5FMGW/SPCA[Pb] | |
| EP5R[Pb] | |
| EP7[Pb] | |
| EP7 GW[Pb] | |
| EP77[Pb] | |
| EP77GW[Pb] | |
| EP8[Pb] | |
| EP8GW[Pb] | |
| EP8LT[Pb] | |
| EP8LTGW[Pb] | |
| EP8R[Pb] | |
| EP8RGW[Pb] | |
| EX4[6] [7] | |
| EX4FM[7] | |
| EX4FMGW[7] | |
| EX4GW[6] [7] | |
| EX4R[6] [7] | |
| EX4RGW[6] [7] | |
| EX5[6] [7] | |
| EX5 GW[6] [7] | |
| EX5FM[6] [7] | |
| EX5FMGW[6] [7] | |
[5] Not acceptable for use in contact with alcoholic beverages.
[6] Only acceptable for use in contact with coffee, tea, and potable water.
[7] Certified for use as part of a food equipment item with a resulting overall weighted
average lead content of = 0.25% in the water contact portion of the equipment.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
Facility : Cassano D'Adda, Italy
|
Electrovalves with Nickel-Plated Brass Bodies[1] [Pb] |
|
| 52(1)(2)(3)N(4)(5) | |
| 53(1)(2)(3)N(4)(5) | |
[1] (1) Two digits for the hydraulic connection.
(2) Two digits for seal material.
(3) Three digit for hole diameter in mm (with or without comma, ie 2, 0 or 20 is 2mm).
(4) U, L and Z only differ in the body material; U and L are made of brass and Z is made
of SS.
(5) Five digits for special executions.
(6) Three digits for coil code.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Electrovalves with Plastic Bodies[1] [Pb] |
|
| V3(1)(2)(3)P(4)(5)[2] | |
| V7(1)(2)(3)P(4)(5)[2] | |
| VD(1)(2)(3)P(4)(5) | |
[1] (1) Two digits for the hydraulic connection.
(2) Two digits for seal material.
(3) Three digit for hole diameter in mm (with or without comma, ie 2, 0 or 20 is 2mm).
(4) U, L and Z only differ in the body material; U and L are made of brass and Z is made
of SS.
(5) Five digits for special executions.
(6) Three digits for coil code.
[2] Only acceptable for use in contact with non-carbonated potable water under constant
service pressure, with a maximum contact temperature of 82°C.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Electrovalves with Tin-Nickel Plated Bodies[3] [4] |
|
| 57(1)(2)(3)T(4)(5) | |
| 66(1)(2)(3)T(4)(5) | |
| 83(1)(2)(3)T(4)(5) | |
[3] (1) Two digits for hydraulic connection.
(2) Two digits for seal material.
(3) Three digits for hole diameter in mm (with or without comma, ie 2, 0 or 20 is 2 mm)
(4) Two possible digits for special executions.
(5) Three digits for coil code.
[4] Certified for use as part of a food equipment item with a resulting overall weighted
average lead content of = 0.25% in the water contact portion of the equipment.
|
|
|
Low Lead Brass and Stainless Steel Solenoid Valves[1] [Pb] |
|
| 52(1)(2)(3)(4)(5)(6) | |
| 53(1)(2)(3)(4)(5)(6) | |
| 62(1)(2)(3)(4)(5)(6) | |
[1] (1) Two digits for the hydraulic connection.
(2) Two digits for seal material.
(3) Three digit for hole diameter in mm (with or without comma, ie 2, 0 or 20 is 2mm).
(4) U, L and Z only differ in the body material; U and L are made of brass and Z is made
of SS.
(5) Five digits for special executions.
(6) Three digits for coil code.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
Facility : Cavenago di Brianza (MB), Italy
|
COMPONENTS: |
|
|
Solenoid Water Valve with Plastic Body [Pb] |
|
| W(1)(2)(3)(4)(5)(6)(7)(8)[1] | |
| W(1)(2)(3)(4)(5)(6)3(8)[1] [2] | |
[1] (1) One digit indicating Inlet type
(2) One digit indicating Outlet type
(3) Two digits indicating DN measurement
(4) One Digit: 0 or 1
(5) 1 Digit indicating the capacity of the Flow Restrictor
(6) 1 Digit indicating the presence of a Flow regulator
(7) One digit indicating Filter type, except "3"
(8) One digit indicating the customization
[2] Only acceptable for use in contact with non-carbonated, potable water with a maximum
contact temperature of 82°C.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
Facility : Trivolzio (PV), Italy
|
COMPONENTS: |
|
|
Electrovalves with Nickel-Plated Brass Bodies[5] [Pb] |
|
| 52(1)(2)(3)N(4)(5) | |
| 53(1)(2)(3)N(4)(5) | |
[5] (1) Two digits for the hydraulic connection.
(2) Two digits for seal material.
(3) Three digits for hole diamater in mm (with or without comma, ie 2, 0 or 20 is 2mm).
(4) U, L and Z only differ in the body material; U and L are made of brass and Z is made
of SS.
(5) Five digits for special executions.
(6) Three digits for coil code.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Electrovalves with Plastic Bodies[5] [Pb] |
|
| V3(1)(2)(3)P(4)(5)[6] | |
| V7(1)(2)(3)P(4)(5)[6] | |
| VD(1)(2)(3)P(4)(5) | |
[5] (1) Two digits for the hydraulic connection.
(2) Two digits for seal material.
(3) Three digits for hole diamater in mm (with or without comma, ie 2, 0 or 20 is 2mm).
(4) U, L and Z only differ in the body material; U and L are made of brass and Z is made
of SS.
(5) Five digits for special executions.
(6) Three digits for coil code.
[6] Only acceptable for use in contact with non-carbonated potable water under constant
service pressure, with a maximum contact temperature of 82°C.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Electrovalves with Tin-Nickel Plated Bodies[3] [7] |
|
| 57(1)(2)(3)T(4)(5) | |
| 66(1)(2)(3)T(4)(5) | |
| 83(1)(2)(3)T(4)(5) | |
[3] Certified for use as part of a food equipment item with a resulting overall weighted
average lead content of = 0.25% in the water contact portion of the equipment.
[7] (1) Two digits for hydraulic connection.
(2) Two digits for seal material.
(3) Three digits for hole diameter in mm (with or without comma, ie
2,0 or 20 is 2mm)
(4) Two possible digits for special executions.
(5) Three digits for coil code.
|
|
|
Low Lead Brass and Stainless Steel Solenoid Valves[5] [Pb] |
|
| 52(1)(2)(3)(4)(5)(6) | |
| 53(1)(2)(3)(4)(5)(6) | |
| 62(1)(2)(3)(4)(5)(6) | |
[5] (1) Two digits for the hydraulic connection.
(2) Two digits for seal material.
(3) Three digits for hole diamater in mm (with or without comma, ie 2, 0 or 20 is 2mm).
(4) U, L and Z only differ in the body material; U and L are made of brass and Z is made
of SS.
(5) Five digits for special executions.
(6) Three digits for coil code.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
One Way Valve - C Series[8] [Pb] |
|
| C1NA75 | |
| C1NAI | |
| C1NAV | |
| C3NAI | |
[8] (1) One character for spring load.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Fitting [Pb] |
|
| Pipetta | |
| Raccordino 90º[1] | |
| Raccordo Bar[2] | |
[1] Not acceptable for use in contact with alcoholic beverages.
[2] Only acceptable for use in contact with coffee, tea, and potable water.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Valve (Valvola)[1] [Pb] |
|
| S1[2] | |
| S11[2] | |
| S2[4] | |
| S22[4] | |
| S3 | |
| S3BP | |
| S3HP | |
| S3HP/R | |
| S4 | |
[1] Not acceptable for use in contact with alcoholic beverages.
[2] Only acceptable for use in contact with coffee, tea, and potable water.
[4] Only acceptable for use in contact with non-carbonated, potable water with a maximum
contact temperature of 82°C.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Water Oscillating Pump - E Range[1] |
|
| EAP4[Pb] | |
| EAP5[Pb] | |
| EAP7[Pb] | |
| EAX4[3] | |
| EAX5[3] | |
| EFP4[Pb] | |
| EFP5[Pb] | |
| EFP7[Pb] | |
| EFX4[3] | |
| EFX5[3] | |
| EK[Pb] | |
| EK2[Pb] | |
| EK2GW[Pb] | |
| EN4[Pb] | |
| EN4FM[3] | |
| EN4FMCA[3] | |
| EP4[Pb] | |
| EP45[Pb] | |
| EP4FM[Pb] | |
| EP4FMGW[Pb] | |
| EP4GW[Pb] | |
| EP4R[Pb] | |
| EP4RGW[Pb] | |
| EP5[Pb] | |
| EP5BN[Pb] | |
| EP5FM[Pb] | |
| EP5FM/SP[Pb] | |
| EP5FMGW[Pb] | |
| EP5FMGW/CA[Pb] | |
| EP5FMGW/SP[Pb] | |
| EP5FMGW/SPCA[Pb] | |
| EP5GW[Pb] | |
| EP5R[Pb] | |
| EP7[Pb] | |
| EP77[Pb] | |
| EP77GW[Pb] | |
| EP7GW[Pb] | |
| EP8[Pb] | |
| EP8GW[Pb] | |
| EP8LT[Pb] | |
| EP8LTGW[Pb] | |
| EP8R[Pb] | |
| EP8RGW[Pb] | |
| EX4[2] [3] | |
| EX4FM[2] [3] | |
| EX4FMGW[2] [3] | |
| EX4GW[2] [3] | |
| EX4R[2] [3] | |
| EX4RGW[2] [3] | |
| EX5[2] [3] | |
| EX5FM[2] [3] | |
| EX5FMGW[2] [3] | |
| EX5GW[2] [3] | |
[1] Not acceptable for use in contact with alcoholic beverages.
[2] Only acceptable for use in contact with coffee, tea, and potable water.
[3] Certified for use as part of a food equipment item with a resulting overall weighted
average lead content of = 0.25% in the water contact portion of the equipment.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Water Oscillating Pump - HF[1] [Pb] |
|
| B6 | |
| HF | |
| HF/S | |
| HF2 | |
| HF2S | |
[1] Not acceptable for use in contact with alcoholic beverages.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
|
Water Oscillating Pump - NME Range [Pb] |
|
| NME1[1] | |
| NME1C[1] | |
| NME1S[1] | |
| NME2[1] | |
| NME3[1] | |
| NME3S[1] | |
| NME4[1] | |
| NMECC | |
| NMECC2 | |
| NMEHP1[1] | |
| NMEHP1/S[1] | |
| NMEHP2[1] | |
| NMEHP2/S[1] | |
| NMEHP3[1] | |
| NMEHP3/S[1] | |
| NMEHP4[1] | |
| NMEHP4/S[1] | |
[1] Not acceptable for use in contact with alcoholic beverages.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
|
Number of matching Manufacturers is 1
Number of matching Products is 292
Processing time was 0 seconds


