NSF Product and Service Listings
These NSF Official Listings are current as of Saturday, July 12, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/food/Listings.asp?Standard=169&Company=C0144789&
NSF/ANSI 169
Special Purpose Food Equipment and Devices
Special Purpose Food Equipment and Devices
AVS Römer GmbH & Co. KG | |
Werk Grafenau | |
Reismühle 3 | |
94481 Grafenau | |
Germany | |
49 817 992 610 | |
Visit this company's website |
Facility : Grafenau, Germany
COMPONENTS: |
|
External Gear Pump EGP Series[1] [Pb] |
|
EGP(1)-X4(2)(3)-P4(4)A-(5)(6)(7)(6)(8)-(9)-(10) | |
[1] (1) One number to identify rinsing concept: 1, 2, 3… (2) One character to localise body connection: S, V, U (3) One character to identify connection sealing type: O, D, F (4) Three numbers to identify flow rate: 050, 060, 080, 110 (5) One character and/or one number to identify connection material: 0, P3, X4 (6) One character to describe connection type: E, R, D, G, T, F (7) 2 digits number to describe connection size: 18, 44, 66, 64, 88, 86 (8) Two charter to identify sealing material and type: FF, PF, FT, PT (9) Up to 5 possible digits to describe electrical customization (10) Optional S (XXX) numbering of customer specific version. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|
Flowcontrol and Check Valve from PPSU[2] [Pb] |
|
AFO-9(2)-P3(9)-(3)-(3)(8)-(4)-S(10) | |
FFO-9(2)P3-(3)-(3)-(3)(8)-(4)-(5)-S(10) | |
MFV-9(2)-P3(9)-(3)-(3)-(3)-(3)(8)-(4)-(6)-S(10) | |
RFO-9(2)-P3(9)-(3)-(3)(8)-(4)-S(10) | |
SMF-9(2)P3-(3)-(3)(8)-(4)-(7)-S(10) | |
SVK(1)-9(2)-P3(9)-(3)-(3)(8)-(4)-S(10) | |
UDV-9(2)P3-(3)-(3)-(3)(8)-(4)-(6)-S(10) | |
VNR(1)-9(2)-P3(9)-(3)-(3)-(3)(8)-(4)-(6)-S(10) | |
VRN(1)-9(2)-P3(9)-(3)-(3)-(3)(8)-(4)-(6)-S(10) | |
[2] (1) 1-2 digits indicate a special version, e.g spring position (2) 2 digits indicate fitting type (3) 1-4 digits indicate push-in connector size; multiple entries are not applicable for the same size (4) Up to 8 digits indicate the thread size and type, stem connector, hosetail or bayonet; omitted if only push-in connection (5) 3-4 digits indicate throttle (6) 3 digits indicate opening pressure; not applicable at 0.1 bar (7) Up to 5 digits indicate the mesh size and material (8) Sealing material: FF - FPM FR - FPM FT - FPM PF - EPDM QF - VMQ QFF - FPM + VMQ QPF - EPDM + VMQ QFT - FPM + VMQ QPT - EPDM + VMQ (9) 2 digits indicate nominal diameter (10) Optional S (+1-2 digits) indicate a specific version [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|
Flowcontrol and Check Valve from Stainless Steel[3] [Pb] |
|
VNR-951-X4(N)-(1)(A)-(2)-S(X) | |
VRN-951-X4(N)-(1)-(2)(A)-S(X) | |
[3] (N) Nominal diameter: DN2 (20), DN3 (30), DN4 (40) (1) Plug connection diameter, available Ø4 up to Ø12mm (2) Screw connection, available in 1/8", 1/4", 3/8", 1/8K, 1/4K, 3/8K, M5, M10x1 and M12x1 (A) O-ring material: FF - FPM / FDA compliant / black FR - FPM / FDA compliant / red PF - HITEC EPDM (X) Customer specific version [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|
Flowcontrol and check valves from PVDF[4] [5] [Pb] |
|
TTV-958-V(1)-(2)(3)-(4) | |
[4] (1) 2 digits indicating nominal diameter: DN0,5 (05) DN1 (10) DN1,5 (15) DN2 (20), DN2,5 (25) DN3 (30), DN3,5 (35) DN4 (40) DN4,5 (45) DN5 (50) (2) Digits indicating plug connection diameter, between 4 and 8 and 1/4" (3) O-ring material: FF - FKM black FR - FKM red PF - HITEC EPDM QF - Silicone QFF - FKM black + silicone QFR - FKM red + silicone QPF - Hitec EPDM + silicone (4) Optional: S (X) numbering of customer specific version, where X ranges from 01 to 999 [5] For use in contact with coffee, tea and water only. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|
Measurement and control - Electronic flow control valve[6] [Pb] |
|
EFC-(7)(8)-(1)(B)(C)(9)-(2)-(3)(D)-(J)-(L)-(SX) | |
EFC-(7)(SY)(8)-(1)(B)(C)(9)-(2)-(3)(D)-(J)-(L)-(SX) | |
[6] (1) One digit or two characters to identify series, (1= RAPID, 9 = ELSA, FL = sub-base) (2) 1 or 2 digits indicating push-in connection diameter for ELSA connection or RAPID push-on connection for tube (3) Optional 1 or 2 digits indicating second push-in connection diameter for ELSA connection or RAPID push-on connection for tube; (4) 3 or 4 digits to indicate start of measuring range (5) 3 digits to indicate end of measuring range (6) 2 digits to identify the maximum pressure in bar (7) digit to identify type of motor (8) digit to identify type of electronic - not applicable for customer specific version (SY) (9) 2 digits nominal diameter (A) 2 digits to describe variant – not applicable for customer specific version (SY) (B) 2 digits to describe fitting type / type of sub-base body (C) housing material: PPSU (P3) / PVDF (V) (D) sealing material: FKM FDA konform (FF) / EPDM FDA konform (PF) (E) combination of 1 digit and 2 characters / 2 digits and 1 character / 3 digits (F) 2 digits to identify supply voltage; e.g. 5V (05) or 36V (36) (G) digit to describe variant: 0 = default, V = vacuum (H) sensor housing material; e.g. stainless steel 1.4404 (X04) – not applicable for ceramic housing (I) type of sensor - (for example PT100 , NTC10, …) (J) combination of 1 digit and 2 characters / 2 digits and 1 character / 3 digits or 3 characters to describe control signal (analog/digital) - not applicable for type of electronic "0" (L) 2 digits to identify cable length / supply connection – not applicable for (SX) Optional: Indicates customer specific version (SY) Optional: Indicates customer specific variant [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|
Measurement and control - Plug-in Sensors[7] [Pb] |
|
BPS-(1)(2)-(3)-(3)(4)-(5)(6)-(11) | |
XLS-(1)(2)-(3)-(3)(4)-(5)(6)-(7)-(9)-(10)-(11) | |
XTL-(1)(2)-(3)-(3)(4)-(5)(6)-(7)-(8)-(9)-(10)-(11) | |
XTS-(1)(2)-(3)-(3)(4)-(5)(6)-(7)-(8)-(9)-(10)-(11) | |
[7] (1) Optional 3 digits indicate fitting type (2) Optional 2-4 digits indicate the material: P3 (PPSU), P5 (PEEK), X4 (1.4404), X5 (1.4305) (3) 1-4 digits indicate push-in connector size; multiple entries are not applicable for the same size (4) Optional 1-2 digits indicate the sealing material FF = FKM PF = EPDM QF = VMQ (5) Optional up to 8 digits indicate the thread size and type (6) Optional 1-3 digits indicate the thread material (stainless steel) (7) 2-3 digits indicate the sensor material (stainless steel) (8) 2-8 digits indicate the type of sensor (9) 2-6 digits indicate the sleeve length (10) 2-4 digits indicate the cable length (11) Optional S (+1-3 digits) indicate a specific version [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|
Measurement and control - Temperature sensor[6] [Pb] |
|
ITS-(1)(B)(C)-(2)-(3)(D)-(H)-(I)-(SX) | |
ITS-(1)(B)(C)-(2)-(3)(D)-(H)-(I)-(SX) | |
[6] (1) One digit or two characters to identify series, (1= RAPID, 9 = ELSA, FL = sub-base) (2) 1 or 2 digits indicating push-in connection diameter for ELSA connection or RAPID push-on connection for tube (3) Optional 1 or 2 digits indicating second push-in connection diameter for ELSA connection or RAPID push-on connection for tube; (4) 3 or 4 digits to indicate start of measuring range (5) 3 digits to indicate end of measuring range (6) 2 digits to identify the maximum pressure in bar (7) digit to identify type of motor (8) digit to identify type of electronic - not applicable for customer specific version (SY) (9) 2 digits nominal diameter (A) 2 digits to describe variant – not applicable for customer specific version (SY) (B) 2 digits to describe fitting type / type of sub-base body (C) housing material: PPSU (P3) / PVDF (V) (D) sealing material: FKM FDA konform (FF) / EPDM FDA konform (PF) (E) combination of 1 digit and 2 characters / 2 digits and 1 character / 3 digits (F) 2 digits to identify supply voltage; e.g. 5V (05) or 36V (36) (G) digit to describe variant: 0 = default, V = vacuum (H) sensor housing material; e.g. stainless steel 1.4404 (X04) – not applicable for ceramic housing (I) type of sensor - (for example PT100 , NTC10, …) (J) combination of 1 digit and 2 characters / 2 digits and 1 character / 3 digits or 3 characters to describe control signal (analog/digital) - not applicable for type of electronic "0" (L) 2 digits to identify cable length / supply connection – not applicable for (SX) Optional: Indicates customer specific version (SY) Optional: Indicates customer specific variant [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|
Measurement and control - conductivity sensor[6] [Pb] |
|
ICS-(1)(B)(C)-(2)-(3)-(D)-(4)-(5)-E-(L)-(SX) | |
ICS-(SY)(A)-(1)(B)(C)-(2)-(3)-(D)-(4)-(5)-(E)-(L)-(SX) | |
[6] (1) One digit or two characters to identify series, (1= RAPID, 9 = ELSA, FL = sub-base) (2) 1 or 2 digits indicating push-in connection diameter for ELSA connection or RAPID push-on connection for tube (3) Optional 1 or 2 digits indicating second push-in connection diameter for ELSA connection or RAPID push-on connection for tube; (4) 3 or 4 digits to indicate start of measuring range (5) 3 digits to indicate end of measuring range (6) 2 digits to identify the maximum pressure in bar (7) digit to identify type of motor (8) digit to identify type of electronic - not applicable for customer specific version (SY) (9) 2 digits nominal diameter (A) 2 digits to describe variant – not applicable for customer specific version (SY) (B) 2 digits to describe fitting type / type of sub-base body (C) housing material: PPSU (P3) / PVDF (V) (D) sealing material: FKM FDA konform (FF) / EPDM FDA konform (PF) (E) combination of 1 digit and 2 characters / 2 digits and 1 character / 3 digits (F) 2 digits to identify supply voltage; e.g. 5V (05) or 36V (36) (G) digit to describe variant: 0 = default, V = vacuum (H) sensor housing material; e.g. stainless steel 1.4404 (X04) – not applicable for ceramic housing (I) type of sensor - (for example PT100 , NTC10, …) (J) combination of 1 digit and 2 characters / 2 digits and 1 character / 3 digits or 3 characters to describe control signal (analog/digital) - not applicable for type of electronic "0" (L) 2 digits to identify cable length / supply connection – not applicable for (SX) Optional: Indicates customer specific version (SY) Optional: Indicates customer specific variant [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|
Measurement and control -Pressure sensor[6] [Pb] |
|
IPS-V(F)-(1)(B)(C)-(2)-(3)(D)-(G)(6)-(L)-(SX) | |
IPS-V(F)-(1)(B)(C)-(2)-(3)(D)-(G)(6)-(L)-(SX) | |
[6] (1) One digit or two characters to identify series, (1= RAPID, 9 = ELSA, FL = sub-base) (2) 1 or 2 digits indicating push-in connection diameter for ELSA connection or RAPID push-on connection for tube (3) Optional 1 or 2 digits indicating second push-in connection diameter for ELSA connection or RAPID push-on connection for tube; (4) 3 or 4 digits to indicate start of measuring range (5) 3 digits to indicate end of measuring range (6) 2 digits to identify the maximum pressure in bar (7) digit to identify type of motor (8) digit to identify type of electronic - not applicable for customer specific version (SY) (9) 2 digits nominal diameter (A) 2 digits to describe variant – not applicable for customer specific version (SY) (B) 2 digits to describe fitting type / type of sub-base body (C) housing material: PPSU (P3) / PVDF (V) (D) sealing material: FKM FDA konform (FF) / EPDM FDA konform (PF) (E) combination of 1 digit and 2 characters / 2 digits and 1 character / 3 digits (F) 2 digits to identify supply voltage; e.g. 5V (05) or 36V (36) (G) digit to describe variant: 0 = default, V = vacuum (H) sensor housing material; e.g. stainless steel 1.4404 (X04) – not applicable for ceramic housing (I) type of sensor - (for example PT100 , NTC10, …) (J) combination of 1 digit and 2 characters / 2 digits and 1 character / 3 digits or 3 characters to describe control signal (analog/digital) - not applicable for type of electronic "0" (L) 2 digits to identify cable length / supply connection – not applicable for (SX) Optional: Indicates customer specific version (SY) Optional: Indicates customer specific variant [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|
Push-In and Push-On Fittings and Fittings Accessories from Metal[8] [Pb] |
|
121(B)-(3)(M)-(2)(A)-S(X) | |
130(B)-(3)(M)-(2)(A)-S(X) | |
141(B)-(3)(M)-(2)-S(X) | |
142(B)-(3)(M)-(2)-S(X) | |
150(B)-(3)(M)-(2)-S(X) | |
151(B)-(3)(M)-(2)(A)-S(X) | |
154(B)-(3)(M)-S(X) | |
155(B)-(3)(M)-S(X) | |
202(B)-(2)(A)-(2)-S(X) | |
250(B)-(2)(A)-S(X) | |
251(B)-(2)-(2)(A)-S(X) | |
252(B)-(2)(A)-(2)-S(X) | |
253(B)-(2)(A)-(2)-S(X) | |
254(B)-(2)-S(X) | |
255(B)-(2)-(2)-S(X) | |
260(B)-(1)-(2)(A)-S(X) | |
262(B)-(2)(A)-S(X) | |
904(B)-D(1)-D(1)-S(X) | |
908(B)-(1)(A)-(2)-S(X) | |
909(B)-(1)(A)-(2)-S(X) | |
911(B)-(1)(A)-D(1)-S(X) | |
912(B)-(1)-(1)(A)-D(1)-S(X) | |
921(B)-(1)-(1)(A)-(2)-S(X) | |
922(B)-(1)-(1)(A)-(2)-S(X) | |
930(B)-(1)(A)-(2)-S(X) | |
941(B)-(1)-(1)-(A)-(2)-S(X) | |
945(B)-(1)(A)-(2)-S(X) | |
946(B)-(1)(A)-(2)-S(X) | |
947(B)-(1)(A)-D(1)-S(X) | |
949(B)-(1)(A)-(2)-S(X) | |
950(B)-(1)(A)-(2)-S(X) | |
951(B)-(1)(A)-(2)-S(X) | |
954(B)-(1)-(1)-(1)(A)-S(X) | |
955(B)-(1)-(1)(A)-S(X) | |
958(B)-(1)-(1)(A)-S(X) | |
959(B)-(1)-(1)(A)-S(X) | |
971(B)-D(1)-S(X) | |
973(B)-(1)(A)-(C)-(D)-S(X) | |
973MB-(1)(A)-(C)-(D)-S(X) | |
975(B)-(1)(A)-(C)-(D)-S(X) | |
975MB-(1)(A)-(C)-(D)-S(X) | |
976(B)-(1)(A)-S(X) | |
979(B)-(1)(A)-(2)-S(X) | |
982(B)-(1)-(1)-(1)(A)-S(X) | |
992(B)-(1)-(1)(A)-(2)-S(X) | |
[8] (1) 1-4 digits indicate stem connector, hose tail or push-in connector size; multiple entries are not applicable for the same size (2) Up to 8 digits indicate the thread size and type (3) 3-7 digits indicate Rapid connection (A) Optional sealing material: FF, FT = FPM; PF = EPDM; QF = VMQ (B) Body: X4, X44, X4M, X44M = 1.4404; X5, X54= 1.5305 (C) 1-2 digits indicate release button material (D) Release button colour (M) Appendix in case of union nut made of brass (no food contact) S(X) Optional: indicates customer specific version [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|
Push-in-Fittings from PK[9] [Pb] |
|
908PK-(1)(3)-(2)-(4) | |
911PK-(1)(3)-D(1)-(4) | |
912PK-(1)-(1)(3)-D(1)-(4) | |
921PK-(1)-(1)(3)-(2)-(4) | |
922PK-(1)-(1)(3)-(2)-(4) | |
923PK-(1)-(1)(3)-(2)-(4) | |
930PK-(1)(3)-(2)-(4) | |
930PK-(1)(3)-(2)-(4) | |
946PK-(1)(3)-(2)-(4) | |
951PK-(1)(3)-(2)-(4) | |
954PK-(1)-(1)-(1)(3)-(4) | |
955PK-(1)-(1)(3)-(4) | |
958PK-(1)-(1)(3)-(4) | |
970PK-(1)-(1)(3)-(2)-(4) | |
979PK-(1)(3)-(2)-(4) | |
982PK-(1)-(1)-(1)(3)-(4) | |
992PK-(1)-(1)(3)-(2)-(4) | |
993PK-(1)-(1)(3)-(2)-(4) | |
[9] (1) 1-3 digits indicate stem connector, hose tail or push-in connector size; multiple entries are not applicable for the same size (2) Up to 10 digits indicate the thread size, type and material (3) Sealing material: FT - FKM, PT - EPDM (4) Optional: S followed by digits/numbers, indicates customer specific version [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|
Push-in-Fittings from PPSU[10] [Pb] |
|
240P3-(1)-(2)(A)-S(X) | |
904P3-D(1)-D(1)-S(X) | |
905P3-(1)(A)-(1)-S(X) | |
907P3-D(1)-(1)-S(X) | |
911P3-(1)(A)-D(1)-S(X) | |
912P3-(1)-(1)(A)-D(1)-S(X) | |
913P3-(1)-(1)(A)-D(1)-S(X) | |
921P3-(1)-(1)(A)-(2)-S(X) | |
922P3-(1)-(1)(A)-(2)-S(X) | |
923P3-(1)-(1)(A)-(2)-S(X) | |
930P3-(1)(A)-(2)-S(X) | |
947P3-(1)(A)-D(1)-S(X) | |
951P3-(1)(A)-(2)-S(X) | |
954P3-(1)-(1)-(1)(A)-S(X) | |
955P3-(1)-(1)(A)-S(X) | |
958P3-(1)-(1)(A)-S(X) | |
959P3-(1)-(1)(A)-S(X) | |
960P3-(1)-(1)-(1)-(1)(A)-S(X) | |
970P3-(1)-(1)(A)-(2)-S(X) | |
971P3-D(1)-S(X) | |
979P3-(1)(A)-(2)-S(X) | |
982P3-(1)-(1)-(1)(A)-S(X) | |
984P3-(1)-(1)-(1)-(1)-(1)(A)-S(X) | |
985P3-(1)-(1)-(1)-(1)-(1)(A)-S(X)[10] | |
992P3-(1)-(1)(A)-(2)-S(X) | |
993P3-(1)-(1)(A)-(2)-S(X) | |
[10] (1) 1-3 digits indicate stem connector, hose tail or push-in connector size; multiple entries are not applicable for the same size (2) Up to 8 digits indicate the thread size and type (A) Sealing material: FF - FPM FT - FPM PF - EPDM QF - VMQ (F) Mesh size of the stainless steel filter S(X) Optional - numbering only in case of customer specific version [10] (1) 1-3 digits indicate stem connector, hose tail or push-in connector size; multiple entries are not applicable for the same size (2) Up to 8 digits indicate the thread size and type (A) Sealing material: FF - FPM FT - FPM PF - EPDM QF - VMQ (F) Mesh size of the stainless steel filter S(X) Optional - numbering only in case of customer specific version [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|
Push-in-Fittings from PVDF[11] [Pb] |
|
911V-(1)(A)-(2)-S(X) | |
912V-(1)(A)-(2)-S(X) | |
921V-(1)(A)-(3)-S(X) | |
922V-(1)(A)-(3)-S(X) | |
923V-(1)(A)-(3)-S(X) | |
930V-(1)(A)-(3)-S(X) | |
945V-(1)(A)-(3)-S(X) | |
954V-(1)(A)-(2)-S(X) | |
955V-(1)(A)-(2)-S(X) | |
958V-(1)(A)-S(X) | |
959V-(1)(A)-(2)-S(X) | |
961V-(1)(A)-(3)-S(X) | |
970V-(1)(A)-(3)-S(X) | |
971V-(1) | |
972V-(1)(A)-S(X) | |
979V-(1)(A)-(3)-S(X) | |
982V-(1)(A)-(2)-S(X) | |
992V-(1)(A)-(3)-S(X) | |
993V-(1)(A)-(3)-S(X) | |
[11] (1) Plug connection diameter, available Ø4 up to Ø12mm (2) Plug connection diameter, available Ø4 up to Ø12mm (3) Screw connection, available in 1/8", 1/4", 3/8", 1/4K, M5 (A) O-ring material: FF - FPM / FDA compliant / black FR - FPM / FDA compliant / red PF - HITEC EPDM S(X) Indicates customer specific version [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|
Push-in-Fittings from Stainless Steel[12] [Pb] |
|
121(B)-(3)(M)-(2)(A)-S(X) | |
130(B)-(3)(M)-(2)(A)-S(X) | |
141(B)-(3)(M)-(2)-S(X) | |
142(B)-(3)(M)-(2)-S(X) | |
150(B)-(3)(M)-(2)-S(X) | |
151(B)-(3)(M)-(2)(A)-S(X) | |
154(B)-(3)(M)-S(X) | |
155(B)-(3)(M)-S(X) | |
202(B)-(2)(A)-(2)-S(X) | |
250(B)-(2)(A)-S(X) | |
251(B)-(2)-(2)(A)-S(X) | |
252(B)-(2)(A)-(2)-S(X) | |
253(B)-(2)(A)-(2)-S(X) | |
254(B)-(2)-S(X) | |
255(B)-(2)-(2)-S(X) | |
260(B)-(1)-(2)(A)-S(X) | |
262(B)-(2)(A)-S(X) | |
904(B)-D(1)-D(1)-S(X) | |
907(B)-D(1)-(1)-S(X) | |
908(B)-(1)(A)-(2)-S(X) | |
909(B)-(1)(A)-(2)-S(X) | |
911(B)-(1)(A)-D(1)-S(X) | |
912(B)-(1)-(1)(A)-D(1)-S(X) | |
921(B)-(1)-(1)(A)-(2)-S(X) | |
922(B)-(1)-(1)(A)-(2)-S(X) | |
930(B)-(1)(A)-(2)-S(X) | |
941(B)-(1)-(1)-(A)-(2)-S(X) | |
945(B)-(1)(A)-(2)-S(X) | |
946(B)-(1)(A)-(2)-S(X) | |
947(B)-(1)(A)-D(1)-S(X) | |
949(B)-(1)(A)-(2)-S(X) | |
950(B)-(1)(A)-(2)-S(X) | |
951(B)-(1)(A)-(2)-S(X) | |
954(B)-(1)-(1)-(1)(A)-S(X) | |
955(B)-(1)-(1)(A)-S(X) | |
958(B)-(1)-(1)(A)-S(X) | |
959(B)-(1)-(1)(A)-S(X) | |
971(B)-D(1)-S(X) | |
973(B)-(1)(A)-(C)-(D)-S(X) | |
973MB-(1)(A)-(C)-(D)-S(X) | |
975(B)-(1)(A)-(C)-(D)-S(X) | |
975MB-(1)(A)-(C)-(D)-S(X) | |
976(B)-(1)(A)-S(X) | |
979(B)-(1)(A)-(2)-S(X) | |
982(B)-(1)-(1)-(1)(A)-S(X) | |
992(B)-(1)-(1)(A)-(2)-S(X) | |
[12] (1) 1-4 digits indicate stem connector, hose tail or push-in connector size; multiple entries are not applicable for the same size (2) Up to 8 digits indicate the thread size and type (3) 3-7 digits indicate Rapid connection (A) Optional sealing material FF, FT - FPM PF - EPDM QF - VMQ (B) Body - X4, X44, X4M, X44M - 1.4404; X5, X54 - 1.4305 (C) 1-2 digits indicate release button material (D) Release button colour (M) Appendix in case of union nut made of brass (no food contact) S(X) Optional - Indicates customer specific version [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|
Solenoid valve - EAV series[13] [Pb] |
|
EAV-(1)(2)(12)-(3)(4)-(5)-(5)-(5)(6)(7)-(8)-(9)-(10) | |
EAV-711(2)-(3)(4)-(5)-(5)(6)(7)(8)-(9)-(10)[14] | |
EAV-811(2)-(3)(4)-(5)-(5)(6)(7)-(8)-(9)-(10)[14] | |
EAV-S(11)(2)(12)-(3)(4)-(5)-(5)-(5)(6)(7)-(8)-(9)-(10) | |
EAV-S7(13)1-(2)-(3)(4)-(5)-(5)(6)(7)(8)-(9)-(10)[14] | |
EAV-S8(13)1-(2)-(3)(4)-(5)-(5)(6)(7)-(8)-(9)-(10)[14] | |
EAV-S90(2)-(3)(4)-(5)-(5)(6)(7)-(8)-(9)-(10)[16] | |
EAV-S91(2)-(3)(4)-(5)-(5)(6)(7)-(8)-(9)-(10)[14] | |
FPV-(1)(2)(12)-(3)(4)-(5)-(5)(6)(7)-(8)-(9)-(10) | |
FPV-S(11)(2)(12)-(3)(4)-(5)-(5)(6)(7)-(8)-(9)-(10) | |
[13] (1) 3 digits indicate the series and version. (2) Optional 2-4 digits indicate the material: X4, X4M, X44M = 1.4404; X5 = 1.4305; P3 = PPSU. (3) 1 digit indicates the function. (4) 2 digits indicate the nominal diameter. (5) 1-3 digits indicate the connection; multiple entries are not applicable for the same size. All connections are certified. (6) 2 digits indicate the sealing material: PF = EPDM; FF = FPM. (7) Optional 1 digit indicates the hexagonal plunger. (8) Optional S (+1-2 digits) indicate a specific version that does not impact certification. (9) Optional 4-5 digits indicate the voltage and current. (10) 2-3 digits indicate the solenoid coil; 00 = partial solenoid valve without solenoid coil. (11) 2-3 digits indicate a specific version that does not impact certification. (12) Optional / + 1-2 digits indicate a battery version. (13) digit 1-99 indicates specific version that does not impact certification [14] Only acceptable for use in contact with non-carbonated, potable water under constant service pressure. [16] For use in contact with coffee, tea and water only. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|
Solenoid valves - ETV and ELV[15] [Pb] |
|
ELV-(1)(9)-(2)(3)-(4)-(4)-(4)(5)-(6)-(7) | |
ELV-2S(8)(9)-(2)(3)-(4)-(4)-(4)(5)-(6)-(7) | |
ELV-S(8)-(2)(3)-(4)-(4)-(4)(5)-(6)-(7) | |
ETV-(1)(9)-(2)(3)-(4)-(4)-(4)(5)-(6)-(7) | |
ETV-2S(8)(9)-(2)(3)-(4)-(4)-(4)(5)-(6)-(7) | |
ETV-S(8)-(2)(3)-(4)-(4)-(4)(5)-(6)-(7) | |
[15] (1) 3 digits indicate the series and version (2) 1 digit indicates the function (3) 2 digits indicate the nominal diameter (4) 1-3 digits indicate the connection type and size or flange version; multiple entries are not applicable for the same size (5) 2 digits indicate the sealing material (6) 5-6 digits indicate the voltage and current (7) 2 digits indicate the solenoid coil (8) 2-3 digits indicate a specific version (9) Optional 4-5 digits indicate a battery version [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Number of matching Manufacturers is 1
Number of matching Products is 195
Processing time was 1 seconds