NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, January 15, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/pdwe/Listings.asp?Standard=419&Company=C0236644&
NSF/ANSI 419
Public Drinking Water Equipment Performance - Filtration
Public Drinking Water Equipment Performance - Filtration
| Scinor Water America, LLC | |
| 16 Mallard Cove | |
| Centerport, NY 11721 | |
| United States | |
| 631-708-9588 | |
| Visit this company's website |
Facility : Beijing Scinor Membrane Technology Co., Ltd., China
| Ultrafiltration Devices | |
| SMT600-P38[1] | |
| SMT600-P50[2] | |
| SMT600-P51[2] | |
| SMT600-P52[2] | |
| SMT600-P53[2] | |
| SMT600-P55[2] | |
| SMT600-P56[2] | |
| SMT600-P57[2] | |
| SMT600-P60[2] | |
| SMT600-P72[2] | |
| SMT600-P80[2] | |
| SMT600-P81[2] | |
| SMT600-S26[3] | |
| SMT600-S40[3] | |
| SMT600-S48[3] | |
| SMT600-S51[3] | |
| SMT600-S60[3] | |
[1] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 6.25 log, and a minimum LRV of 6.08 log. The maximum certified filtrate flux
rate is 120 gfd. Also tested 2/22/2016 for virus removal efficiency, with a mean LRV of
4.34 and a minimum LRV of 2.69 log.
[2] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 6.11 log, and a minimum LRV of 6.06 log. The maximum certified filtrate flux
rate is 120 gfd. Also tested 01/06/2021 for virus removal efficiency, with a mean LRV of
5.20 and a minimum LRV of 5.07 log.
[3] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 6.104 log, and a minimum LRV of 6.04 log. The
maximum certified filtrate flux rate is 120 gfd. Also tested on Dec. 22, 2021 for virus
removal efficiency with a mean LRV of 4.405 and a minimum LRV of 4.1 log.
|
|
Number of matching Manufacturers is 1
Number of matching Products is 17
Processing time was 0 seconds