Class II (Laminar Flow) Biosafety Cabinetry
| Cabinet Style A = Bench Unit With Base or Adjustable Legs Provided B = Bench Unit Without Base or Adjustable Legs Provided C = Console |
Window Type H = Hinged S = Sliding F = Fixed |
Bench Height NA = Not Applicable NP = Not Provided |
CBV = Concurrent Balance Value
Due to a change in nomenclature in NSF/ANSI 49 - 2002 “Class II (Laminar Flow) Biosafety Cabinetry,” Class II, Type A cabinets are now referred to as Class II, Type A1 and Class II, Types B3 and A/B3 cabinets as Class II, Type A2. Class II, Types B1 and B2 cabinets remain unchanged.
Biosafety cabinet models Listed under NSF/ANSI 49 are approved for use with a power supply of 115V/60Hz, unless otherwise noted. If biosafety cabinets have been approved for use with additional power supplies, the power supply will be indicated in the Official Listing.
| Baker Company, Inc. (The) | ![]() |
| 175 Gatehouse Road | |
| Sanford, ME 04073 | |
| United States | |
| 800-992-2537 | |
| 207-324-8773 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| BCG401[1] | B2 | C | 100 - 110 | 35 - 45 | 664 @ 1.6 | 4 | 8S | 35 | I.V. Pole U.V. Light Casters |
| BCG601[1] | B2 | C | 100 - 110 | 35 - 45 | 993 @ 1.6 | 6 | 8S | 35 | I.V. Pole U.V. Light |
| SG404[2] [3] [4] [5] | A2 | A | 100 - 110 | 45 - 55 | N/A | 4 | 8S | 37 | I.V. Pole U.V. Light Casters Canopy Connection |
| SG404[2] [3] [4] [5] | A2 | A | 100 - 110 | 45 - 55 | N/A | 4 | 10S | 37 | I.V. Pole U.V. Light Casters Canopy Connection |
| SG404[2] [3] [4] [5] | A2 | A | 100 - 110 | 45 - 55 | N/A | 4 | 12S | 37 | I.V. Pole U.V. Light Casters Canopy Connection |
| SG504[2] [3] [5] [6] | A2 | A | 100 - 110 | 45 - 55 | N/A | 5 | 8S | 37 | I.V. Pole U.V. Light Casters Canopy Connection |
| SG504[2] [3] [5] [6] | A2 | A | 100 - 110 | 45 - 55 | N/A | 5 | 10S | 37 | I.V. Pole U.V. Light Casters Canopy Connection |
| SG504[2] [3] [5] [7] | A2 | A | 100 - 110 | 43 - 53 | N/A | 5 | 12S | 37 | I.V. Pole U.V. Light Casters Canopy Connection |
| SG604[2] [3] [5] [8] | A2 | A | 100 - 110 | 46 - 56 | N/A | 6 | 8S | 37 | Casters Canopy Connection I.V. Pole U.V. Light |
| SG604[2] [3] [5] [6] | A2 | A | 100 - 110 | 45 - 55 | N/A | 6 | 10S | 37 | Casters Canopy Connection I.V. Pole U.V. Light |
| SG604[2] [3] [5] [9] | A2 | A | 100 - 110 | 40 - 50 | N/A | 6 | 12S | 37 | Canopy Connection Casters I.V. Pole U.V. Light |
[1] Beginning with serial number 103539 for the 4-foot model and serial number 103706 for
the 6-foot model. Inflow nominal setpoint of 105 fpm was established with a direct
airflow reading instrument. This nominal set point was confirmed using the
manufacturer's recommended alternate calculated method with thermal anemometer in a
constricted (3 inch high) access opening (consult manufacturer's operator's manual for
appropriate correction factor), without adjusting cabinet airflow balance. Downflow
nominal set point was established with I.V. Pole and U.V. Light removed. This cabinet
model was Certified to NSF/ANSI 49-2010a. This cabinet qualifies only with the armrest
installed. This cabinet is approved with additional petcocks on the sidewalls and a low
static pressure exhaust plenum. Cabinet models BCG401 INT and BCG601 INT are Certified
for alternate motor/blower combinations and input power supply.
[2] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate calculated method with thermal anemometer in a constricted (3 inch high)
access opening (consult manufacturer's operator's manual for appropriate correction
factor, if applicable).
[3] Baker model designations SG404-AUS and SG604-AUS are Certified to NSF/ANSI 49-2022 for
operation at 220V/50Hz with an 8-inch window opening. Baker model designations
SG404-INT, SG504-INT, and SG604-INT are Certified to NSF/ANSI 49-2022 for operation at
either 220V/50Hz or 220V/60Hz.
[4] Beginning with serial number 110235. Downflow nominal set point of 50fpm was established
with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2022. This cabinet qualifies only with the armrest installed. FlexAir Canopy
connection 333A745 is approved for use with this model.
[5] The maximum height for the fixed height stand with casters is 31 inches. The maximum
height for the adjustable height Channel stand, with bullet feet is 37 inches.
[6] Beginning with serial number 110795. Downflow nominal set point of 50 fpm was
established with the I.V. Pole and U.V. Light removed. This cabinet model was Certified
to NSF/ANSI 49-2022. This cabinet qualifies only with the armrest installed. FlexAir
Canopy connection 336A745 is approved for use with this model.
[7] Beginning with serial number 110795. Downflow nominal set point of 48 fpm was
established with the I.V. Pole and U.V. Light removed. This cabinet model was Certified
to NSF/ANSI 49-2022. This cabinet qualifies only with the armrest installed. FlexAir
Canopy connection 336A745 is approved for use with this model.
[8] Beginning with serial number 110555. Downflow nominal set point of 51 fpm was
established with the I.V. Pole and U.V. Light removed. This cabinet model was Certified
to NSF/ANSI 49-2022. This cabinet qualifies only with the armrest installed. FlexAir
Canopy connection 336A745 is approved for use with this model.
[9] Beginning with serial number 110555. Downflow nominal set point of 45 fpm was
established with the I.V. Pole and U.V. Light removed. This cabinet model was Certified
to NSF/ANSI 49-2022. This cabinet qualifies only with the armrest installed. FlexAir
Canopy connection 336A745 is approved for use with this model.
|
|||||||||
Number of matching Manufacturers is 1
Number of matching Products is 11