NSF/ANSI 49
Class II (Laminar Flow) Biosafety Cabinetry

Cabinet Style
A = Bench Unit With Base or Adjustable Legs Provided
B = Bench Unit Without Base or Adjustable Legs Provided
C = Console
Window Type
H = Hinged
S = Sliding
F = Fixed
Bench Height
NA = Not Applicable
NP = Not Provided

CBV = Concurrent Balance Value

Due to a change in nomenclature in NSF/ANSI 49 - 2002 “Class II (Laminar Flow) Biosafety Cabinetry,” Class II, Type A cabinets are now referred to as Class II, Type A1 and Class II, Types B3 and A/B3 cabinets as Class II, Type A2. Class II, Types B1 and B2 cabinets remain unchanged.

Biosafety cabinet models Listed under NSF/ANSI 49 are approved for use with a power supply of 115V/60Hz, unless otherwise noted. If biosafety cabinets have been approved for use with additional power supplies, the power supply will be indicated in the Official Listing.



 
Nuaire, Inc. 
2100 Fernbrook Lane
Plymouth, MN 55447 
United States 
763-553-1270
Visit this company's website
Facility : Plymouth, MN

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
NU-427-400[1] [2] [3] B1 A 100 - 110 65 - 75 282 @ 0.7 4 8S 32 Bag-In/ Bag-Out
I.V. Pole
U.V. Light
NU-427-600[1] [2] [4] B1 A 100 - 110 65 - 75 474 @ 0.9 6 8S 32 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
NU-540-300[5] A2 A 100 - 110 55 - 65 N/A 3 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-540-300[5] A2 A 100 - 110 55 - 65 N/A 3 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-540-400[5] A2 A 100 - 110 55 - 65 N/A 4 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-540-400[5] A2 A 100 - 110 55 - 65 N/A 4 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-540-500[5] A2 A 100 - 110 57 - 67 N/A 5 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-540-500[5] A2 A 100 - 110 57 - 67 N/A 5 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-540-600[5] A2 A 100 - 110 55 - 65 N/A 6 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-540-600[5] A2 A 100 - 110 55 - 65 N/A 6 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-300[5] A2 A 100 - 110 55 - 65 N/A 3 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-300[5] A2 A 100 - 110 55 - 65 N/A 3 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-300[5] A2 A 100 - 110 55 - 65 N/A 3 12S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-400[5] A2 A 100 - 110 55 - 65 N/A 4 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-400[5] A2 A 100 - 110 55 - 65 N/A 4 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-400[5] A2 A 100 - 110 55 - 65 N/A 4 12S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-500[5] A2 A 100 - 110 57 - 67 N/A 5 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-500[5] A2 A 100 - 110 57 - 67 N/A 5 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-500[5] A2 A 100 - 110 57 - 67 N/A 5 12S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-600[5] A2 A 100 - 110 55 - 65 N/A 6 8S 35 U.V. Light
I.V. Pole
Canopy Connection
NU-543-600[5] A2 A 100 - 110 55 - 65 N/A 6 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-600[5] A2 A 100 - 110 55 - 65 N/A 6 12S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-545-300[6] A2 A 100 - 110 55 - 65 N/A 3 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-545-300[6] A2 A 100 - 110 55 - 65 N/A 3 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-545-400[7] A2 A 100 - 110 55 - 65 N/A 4 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-545-400[7] A2 A 100 - 110 55 - 65 N/A 4 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-545-500[8] A2 A 100 - 110 55 - 65 N/A 5 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-545-500[8] A2 A 100 - 110 55 - 65 N/A 5 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-545-600[9] A2 A 100 - 110 55 - 65 N/A 6 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-545-600[9] A2 A 100 - 110 55 - 65 N/A 6 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-560-400[10] B2 A 100 - 110 55 - 65 859@1.8 4 8S 36 I.V. Pole
U.V. Light
NU-565-400[10] B2 A 100 - 110 55 - 65 859@1.8 4 8S 36 I.V. Pole
U.V. Light
NU-677-400[11] A2 A 100 - 110 55 - 65 N/A 4 12S 38 Canopy Connection
U.V. Light
NU-677-500[12] A2 A 100 - 110 55 - 65 N/A 5 12S 38 Canopy Connection
U.V. Light
NU-677-600[13] A2 A 100 - 110 55 - 65 N/A 6 12S 38 Canopy Connection
U.V. Light
NU-FH677-500[14] A2 A 100 - 110 55 - 65 N/A 5 12S 38 U.V. Light

[1] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
    instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
    density) was confirmed using manufacturer's recommended alternate method with thermal
    anemometer in a constricted (3 inch high) access opening for appropriate correction
    factor, if applicable, without adjusting cabinet airflow balance.
[2] Listed model may be suffixed with E. Certified for use with power supplies of 230V/50Hz
    and 230V/60Hz.
[3] Beginning with Series 60 and higher.  Downflow nominal set-point of 70 fpm was
    established 4 inches above the plane of the window with the I.V. Pole and U.V. Light
    removed.  This cabinet model was Certified to NSF/ANSI 49-2011.  This cabinet qualifies
    with the optional DC motor installed.  Listed model may be prefaced with Q, N, L or S
    (i.e. NU-Q427-400).
[4] Beginning with series 40 and higher.  Downflow nominal set-point of 60 fpm was
    established 4 inches above the plane of the window with the I.V. Pole and U.V. Light
    removed.  This cabinet qualifies with the optional DC motor installed.
    Listed model may be prefaced with Q, N, L or S (i.e. NU-Q427-600).  This cabinet model
    was Certified to NSF/ANSI 49-2011.
[5] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
    instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
    density) was confirmed using manufacturer's recommended alternate method with thermal
    anemometer in a constricted (3 inch high) access opening and applying appropriate
    correction factor without adjusting cabinet airflow balance.  The downflow nominal
    set-point of 60 fpm was established 4 inches above the bottom of the sash with the I.V.
    Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2012.
    Listed model may be prefaced with Q, N, L, or S (e.g. NU-Q540-300).  Certified for use
    with power supplies of 100V/50Hz, 100V/60Hz, 230V/50Hz, and 230V/60Hz.
[6] Beginning with serial number 170844102115.  Inflow nominal set-point of 105 fpm was 
    established with a direct airflow reading instrument.  A corresponding inflow nominal 
    set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
    
    recommended alternate method with thermal anemometer in a constricted (3 inch high) 
    access opening and applying appropriate correction factor without adjusting cabinet
    airflow balance.  The downflow nominal set-point of 60 fpm was established 4 inches
    above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet
    model was 
    Certified to NSF/ANSI 49-2014.  Listed model may be prefaced with Q, N, L, or S 
    (e.g. NU-Q540-300).  Certified for use with power supplies of 100V/50Hz, 100V/60Hz, 
    230V/50Hz, and 230V/60Hz.
    
[7] Beginning with serial number 170847102115.   Inflow nominal set-point of 105 fpm was
    established with a direct airflow reading instrument. A corresponding inflow nominal
    set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
     recommended alternate method with thermal anemometer in a constricted (3 inch high)
    access opening and applying appropriate correction factor without adjusting cabinet
    airflow balance. The downflow nominal set-point of 60 fpm was established 4 inches above
    the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was
    Certified to NSF/ANSI 49-2020.  Listed model may be prefaced with Q, N, L, or S (e.g.
    NU-Q540-300).  Certified for use with power supplies of 100V/50Hz, 100V/60Hz, 230V/50Hz,
    and 230V/60Hz.
[8] Beginning with serial number 170845102115.  Inflow nominal set-point of 105 fpm was
    established with a direct airflow reading instrument.  A corresponding inflow nominal
    set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
    recommended alternate method with thermal anemometer in a constricted (3 inch high)
    access opening and applying appropriate correction factor without adjusting cabinet
    airflow balance.  The downflow nominal set-point of 60 fpm was established 4 inches
    above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet
    model was Certified to NSF/ANSI 49-2014.  Listed model may be prefaced with Q, N, L, or
    S (e.g. NU-Q540-300).  Certified for use with power supplies of 100V/50Hz, 100V/60Hz,
    230V/50Hz, and 230V/60Hz.
    
[9] Beginning with serial number 170846102115.  Inflow nominal set-point of 105 fpm was 
    established with a direct airflow reading instrument.  A corresponding inflow nominal 
    set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
    
    recommended alternate method with thermal anemometer in a constricted (3 inch high) 
    access opening and applying appropriate correction factor without adjusting cabinet
    airflow 
    balance.  The downflow nominal set-point of 60 fpm was established 4 inches above the 
    bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was 
    Certified to NSF/ANSI 49-2014.  Listed model may be prefaced with Q, N, L, or S 
    (e.g. NU-Q540-300).  Certified for use with power supplies of 100V/50Hz, 100V/60Hz, 
    230V/50Hz, and 230V/60Hz.
    
[10] Beginning with serial number 179773041817.  Inflow nominal set-point of 105 fpm was
     established with a direct airflow reading instrument.  A corresponding inflow nominal
     set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
     recommended alternate method with thermal anemometer in a constricted (3 inch high)
     access opening and applying appropriate correction factor without adjusting cabinet
     airflow balance.  The downflow nominal set-point of 60 fpm was established 4 inches
     above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet
     model was Certified to NSF/ANSI 49-2016.  Certified for use with power supplies of
     115V/60Hz, 230V/50Hz and 230V/60Hz. The concurrent balance value was taken with the NSF
     exhaust system conforming to ASHRAE. However, differences due to the	exhaust system,
     cabinet and instrumentation may be present and product specification information should
     be obtained from the manufacturer.									
     
[11] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
     instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
     density) was confirmed using manufacturer's recommended alternate method with thermal
     anemometer in a constricted (3 inch high) access opening and applying appropriate
     correction factor without adjusting cabinet airflow balance.  The downflow nominal
     set-point of 60 fpm was established 4 inches above the bottom of the sash with the U.V.
     Light removed.  This cabinet model was Certified to NSF/ANSI 49-2011.  NuAire canopy
     model NU-911-402 was evaluated as part of the NSF Certification testing procedures.
     
[12] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
     instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
     density) was confirmed using manufacturer's recommended alternate method with thermal
     anemometer in a constricted (3 inch high) access opening and applying appropriate
     correction factor without adjusting cabinet airflow balance.  The downflow nominal
     set-point of 60 fpm was established 4 inches above the bottom of the sash with the U.V.
     Light removed.  This cabinet model was Certified to NSF/ANSI 49-2011.  NuAire canopy
     model NU-911-502 was evaluated as a part of the NSF Certification testing procedures.
[13] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
     instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
     density) was confirmed using manufacturer's recommended alternate method with thermal
     anemometer in a constricted (3 inch high) access opening and applying appropriate
     correction factor without adjusting cabinet airflow balance.  The downflow nominal
     set-point of 60 fpm was established 4 inches above the bottom of the sash with the U.V.
     Light removed.  This cabinet model was Certified to NSF/ANSI 49-2011.  NuAire canopy
     model NU-911-602 was evaluated as part of the NSF Certification testing procedures.
[14] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
     instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
     density) was confirmed using manufacturer's recommended alternate method with thermal
     anemometer in a constricted (3 inch high) access opening and applying appropriate
     correction factor without adjusting cabinet airflow balance. The downflow nominal
     set-point of 60 fpm was established 4 inches above the bottom of the sash with the U.V.
     Light removed. This cabinet model was Certified to NSF/ANSI 49-2012. NuAire canopy model
     NU-911-502 was evaluated as a part of the NSF Certification testing procedures.
     NU-FH677-500 is a modified version of NU-677-500, including feed hoppers.

Facility : Shanghai, China

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
NU-543-300[1] A2 A 100 - 110 55 - 65 N/A 3 10S 35 Canopy Connection
I.V. Pole
U.V. Light
NU-543-400[1] A2 A 100 - 110 55 - 65 N/A 4 10S 35 Canopy Connection
I.V. Pole
U.V. Light
NU-543-500[2] A2 A 100 - 110 57 - 67 N/A 5 10S 35 Canopy Connection
I.V. Pole
U.V. Light
NU-543-600[1] A2 A 100 - 110 55 - 65 N/A 6 10S 35 Canopy Connection
I.V. Pole
U.V. Light

[1] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
    instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
    density) was confirmed using manufacturer's recommended alternate method with thermal
    anemometer in a constricted (3 inch high) access opening and applying appropriate
    correction factor without adjusting cabinet airflow balance.  The downflow nominal
    set-point of 60 fpm was established 4 inches above the bottom of the sash with the I.V.
    pole and U.V. light removed.  This cabinet model was Certified to NSF 49-2012. Listed
    model may be prefaced with Q, N, L, or S (e.g. NU-Q540-300).  Listed model may be
    suffixed with J, K, or S (e.g. NU-543-400S).  Certified for use with power supplies of
    100V/50Hz, 100V/60Hz, 230V/50Hz, and 230V/60Hz.
[2] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
    instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
    density) was confirmed using manufacturer's recommended alternate method with thermal
    anemometer in a constricted (3 inch high) access opening and applying appropriate
    correction factor without adjusting cabinet airflow balance.  The downflow nominal
    set-point of 62 fpm was established 4 inches above the bottom of the sash with the I.V.
    pole and U.V. light removed.  This cabinet model was Certified to NSF 49-2012.  Listed
    model may be prefaced with Q, N, L, or S (e.g. NU-Q540-300).  Listed model may be
    suffixed with J, K, or S (e.g. NU-543-400S).  Certified for use with power supplies of
    100V/50Hz, 100V/60Hz, 230V/50Hz, and 230V/60Hz.