Class II (Laminar Flow) Biosafety Cabinetry
| Cabinet Style A = Bench Unit With Base or Adjustable Legs Provided B = Bench Unit Without Base or Adjustable Legs Provided C = Console |
Window Type H = Hinged S = Sliding F = Fixed |
Bench Height NA = Not Applicable NP = Not Provided |
CBV = Concurrent Balance Value
Due to a change in nomenclature in NSF/ANSI 49 - 2002 “Class II (Laminar Flow) Biosafety Cabinetry,” Class II, Type A cabinets are now referred to as Class II, Type A1 and Class II, Types B3 and A/B3 cabinets as Class II, Type A2. Class II, Types B1 and B2 cabinets remain unchanged.
Biosafety cabinet models Listed under NSF/ANSI 49 are approved for use with a power supply of 115V/60Hz, unless otherwise noted. If biosafety cabinets have been approved for use with additional power supplies, the power supply will be indicated in the Official Listing.
| Chung Fu Technical Development Co., Ltd. | ![]() |
| 7F, No. 687, Mintsu East Road | |
| Taipei 105 | |
| Taiwan | |
| 886 2 2600 1761 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| AHA-133-AA-B[1] [2] | A2 | A | 100 - 110 | 54 - 64 | N/A | 4 | 10S | 28 | I.V. Pole U.V. Light |
| AHA-133-AB-B[1] [2] [3] | A2 | A | 100 - 110 | 54 - 64 | N/A | 4 | 10S | 28 | I.V. Pole U.V. Light |
| AHA-133-AC-B[1] [2] [4] | A2 | A | 100 - 110 | 54 - 64 | N/A | 4 | 10S | 28 | I.V. Pole U.V. Light |
| AHA-133-CA-B[1] [5] | A2 | A | 100 - 110 | 54 - 64 | N/A | 4 | 10S | 28 | I.V. Pole U.V. Light |
| AHA-133-CB-B[1] [3] [5] | A2 | A | 100 - 110 | 54 - 64 | N/A | 4 | 10S | 28 | I.V. Pole U.V. Light |
| AHA-133-CC-B[1] [4] [5] | A2 | A | 100 - 110 | 54 - 64 | N/A | 4 | 10S | 28 | I.V. Pole U.V. Light |
| AHA-193-AA-A[2] [6] | A2 | A | 100 - 110 | 54 - 64 | N/A | 6 | 8S | 29 | I.V. Pole U.V. Light |
| AHA-193-AB-A[2] [3] [6] | A2 | A | 100 - 110 | 54 - 64 | N/A | 6 | 8S | 29 | I.V. Pole U.V. Light |
| AHA-193-AC-A[2] [4] [6] | A2 | A | 100 - 110 | 54 - 64 | N/A | 6 | 8S | 29 | I.V. Pole U.V. Light |
| AHA-193-CA-A[5] [6] | A2 | A | 100 - 110 | 54 - 64 | N/A | 6 | 8S | 29 | I.V. Pole U.V. Light |
| AHA-193-CB-A[3] [5] [6] | A2 | A | 100 - 110 | 54 - 64 | N/A | 6 | 8S | 29 | I.V. Pole U.V. Light |
| AHA-193-CC-A[4] [5] [6] | A2 | A | 100 - 110 | 54 - 64 | N/A | 6 | 8S | 29 | I.V. Pole U.V. Light |
| AHB-133-AA-A[2] [7] | B2 | B | 100 - 110 | 54 - 64 | N/A | 4 | 8S | 34 | I.V. Pole U.V. Light |
| AHB-133-AB-A[2] [3] [7] | B2 | B | 100 - 110 | 54 - 64 | N/A | 4 | 8S | 34 | I.V. Pole U.V. Light |
| AHB-133-AC-A[2] [4] [7] | B2 | B | 100 - 110 | 54 - 64 | N/A | 4 | 8S | 34 | I.V. Pole U.V. Light |
[1] Beginning with serial number AHA1608060. Inflow nominal set point of 105 fpm was
established with a direct airflow reading instrument. A corresponding inflow nominal
set point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
recommended alternate method with thermal anemometer in a constricted (3 inch high)
access opening and applying appropriate correction factor without adjusting cabinet
airflow balance. The downflow nominal set-point of 59 fpm was established 4 inches
above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet
model was Certified to NSF/ANSI 49-2022. Chung Fu Technical Development Co., Ltd. Models
AHA-133-AA-B, AHA-133-AB-B, AHA-133-AC-B, AHA-133-CA-B, AHA-133-CB-B and AHA-133-CC-B
are marketed by Air Science, LLC, USA as Air Science Models AS-AHA-133-AA-B,
AS-AHA-133-AB-B, AS-AHA-133-AC-B, AS-AHA-133-CA-B, AS-AHA-133-CB-B and AS-AHA-133-CC-B,
respectively.
[2] Control panel is touch screen on this model.
[3] Certified for use with power supplies of 230V/50Hz and 230V/60Hz.
[4] Certified for use with power supplies of 100V/50Hz and 100V/60Hz.
[5] Control panel is membrane switch on this model.
[6] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. The downflow nominal set-point of 59 fpm was established 4 inches above the
bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was
Certified to NSF/ANSI 49-2020. Chung Fu Technical Development Co., Ltd. Models
AHA-193-AA-A, AHA-193-AB-A,AHA-193-AC-A, AHA-193-CA-A, AHA-193-CB-A and AHA-193-CC-A are
marketed by Air Science, LLC, USA as Air Science Models AS-AHA-193-AA-A,
AS-AHA-193-AB-A, AS-AHA-193-AC-A, AS-AHA-193-CA-A, AS-AHA-193-CB-A and AS-AHA-193-CC-A,
respectively.
[7] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. The downflow nominal set-point of 59 fpm was established 4 inches above the
bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was
Certified to NSF/ANSI 49-2022.
|
|||||||||