Class II (Laminar Flow) Biosafety Cabinetry
| Cabinet Style A = Bench Unit With Base or Adjustable Legs Provided B = Bench Unit Without Base or Adjustable Legs Provided C = Console |
Window Type H = Hinged S = Sliding F = Fixed |
Bench Height NA = Not Applicable NP = Not Provided |
CBV = Concurrent Balance Value
Due to a change in nomenclature in NSF/ANSI 49 - 2002 “Class II (Laminar Flow) Biosafety Cabinetry,” Class II, Type A cabinets are now referred to as Class II, Type A1 and Class II, Types B3 and A/B3 cabinets as Class II, Type A2. Class II, Types B1 and B2 cabinets remain unchanged.
Biosafety cabinet models Listed under NSF/ANSI 49 are approved for use with a power supply of 115V/60Hz, unless otherwise noted. If biosafety cabinets have been approved for use with additional power supplies, the power supply will be indicated in the Official Listing.
| Suzhou Antai Airtech Co., Ltd. | ![]() |
| No. 2 Weixin Road, SIP | |
| Suzhou, Jiangsu 215122 | |
| China | |
| 86 512 6552 5002 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| BSC-1301 II A2[1] | A2 | A | 100 - 110 | 64 - 74 | N/A | 4 | 10S | 24 | U.V. Light Canopy Connection |
| BSC-1302 II A2[1] [2] | A2 | A | 100 - 110 | 64 - 74 | N/A | 4 | 10S | 24 | U.V. Light Canopy Connection |
[1] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (80 mm high) access opening and applying appropriate
correction factor without adjusting cabinet airflow balance. The downflow nominal
set-point of 69 fpm was established 4 inches above the bottom of the sash with the U.V.
Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. Approved metric
value for cabinet width is 1270 mm, window height is 250 mm, and bench height max is 610
mm.
[2] Certified for use with power supplies of 230V/50Hz and 230V/60Hz.
|
|||||||||
Number of matching Manufacturers is 1
Number of matching Products is 2