NSF/ANSI 49
Class II (Laminar Flow) Biosafety Cabinetry

Cabinet Style
A = Bench Unit With Base or Adjustable Legs Provided
B = Bench Unit Without Base or Adjustable Legs Provided
C = Console
Window Type
H = Hinged
S = Sliding
F = Fixed
Bench Height
NA = Not Applicable
NP = Not Provided

CBV = Concurrent Balance Value

Due to a change in nomenclature in NSF/ANSI 49 - 2002 “Class II (Laminar Flow) Biosafety Cabinetry,” Class II, Type A cabinets are now referred to as Class II, Type A1 and Class II, Types B3 and A/B3 cabinets as Class II, Type A2. Class II, Types B1 and B2 cabinets remain unchanged.

Biosafety cabinet models Listed under NSF/ANSI 49 are approved for use with a power supply of 115V/60Hz, unless otherwise noted. If biosafety cabinets have been approved for use with additional power supplies, the power supply will be indicated in the Official Listing.



 
Qingdao Haier Biomedical Co., Ltd. 
No. 280 Fengyuan Road
High-Tech Zone 
Qingdao 266111 
China 
86 176 6092 6003
Visit this company's website
Facility : Qingdao, China

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
HR900-IIA2-N[1] [2] A2 A 100 - 110 64 - 74 N/A 3 8S 27 U.V. Light
Casters
Hgt Adjustable Stand
HR1200-IIA2-N[1] [3] A2 A 100 - 110 64 - 74 N/A 4 8S 27 U.V. Light
Casters
Hgt Adjustable Stand
HR1800-IIA2-N[1] [4] A2 A 100 - 110 65 - 75 N/A 6 8S 27 U.V. Light
Casters
Hgt Adjustable Stand

[1] This cabinet model was Certified for use with power supplies of 100V/60Hz, 115V/60Hz,
    230V/50Hz, 230V/60Hz
[2] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted access opening (consult
    manufacturer for appropriate correction factor, if applicable), without adjusting
    cabinet airflow balance. Downflow nominal set point of 69 fpm was established U.V. Light
    removed. This cabinet is Certified to NSF/ANSI 49-2022. GFCI outlet is approved for this
    model.
[3] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted access opening (consult
    manufacturer for appropriate correction factor, if applicable), without adjusting
    cabinet airflow balance. Downflow nominal set point of 69 fpm was established U.V. Light
    removed.
    This cabinet is Certified to NSF/ANSI 49-2019. GFCI outlet is approved for this model. 
[4] Beginning with serial number BE0GGBEB200QHM7P0001. Inflow nominal set point of 105 fpm
    was established with a direct airflow reading instrument. This nominal set point was
    confirmed using the manufacturer's recommended alternate method with thermal anemometer
    in a constricted access opening (consult manufacturer for appropriate correction factor,
    if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of
    70 fpm was established U.V. Light removed. This cabinet is Certified to NSF/ANSI 49-2019.


Number of matching Manufacturers is 1
Number of matching Products is 3