Class II (Laminar Flow) Biosafety Cabinetry
| Cabinet Style A = Bench Unit With Base or Adjustable Legs Provided B = Bench Unit Without Base or Adjustable Legs Provided C = Console |
Window Type H = Hinged S = Sliding F = Fixed |
Bench Height NA = Not Applicable NP = Not Provided |
CBV = Concurrent Balance Value
Due to a change in nomenclature in NSF/ANSI 49 - 2002 “Class II (Laminar Flow) Biosafety Cabinetry,” Class II, Type A cabinets are now referred to as Class II, Type A1 and Class II, Types B3 and A/B3 cabinets as Class II, Type A2. Class II, Types B1 and B2 cabinets remain unchanged.
Biosafety cabinet models Listed under NSF/ANSI 49 are approved for use with a power supply of 115V/60Hz, unless otherwise noted. If biosafety cabinets have been approved for use with additional power supplies, the power supply will be indicated in the Official Listing.
| Bioair S.p.A. | ![]() |
| Via Pagano, 61 | |
| 20145 Milan | |
| Italy | |
| 39 03 826 6721 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| SM-49 (Code: LDS4322)[1] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 35 | Canopy Connection Casters I.V. Pole U.V. Light |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted access opening, using the
manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 65 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2022. This cabinet model is Certified for
use with optional touchscreen switch, petcock(s), cable ports(s), AZ1S304 Thimble
adapter canopy connection, a fixed stand with casters (Max Ht. 28"), an adjustable stand
with feet (Max Ht. 35"), and a hydraulic stand with casters (Max Ht. 35").
|
|||||||||
Number of matching Manufacturers is 1