Class II (Laminar Flow) Biosafety Cabinetry
Cabinet Style A = Bench Unit With Base or Adjustable Legs Provided B = Bench Unit Without Base or Adjustable Legs Provided C = Console |
Window Type H = Hinged S = Sliding F = Fixed |
Bench Height NA = Not Applicable NP = Not Provided |
CBV = Concurrent Balance Value
Due to a change in nomenclature in NSF/ANSI 49 - 2002 “Class II (Laminar Flow) Biosafety Cabinetry,” Class II, Type A cabinets are now referred to as Class II, Type A1 and Class II, Types B3 and A/B3 cabinets as Class II, Type A2. Class II, Types B1 and B2 cabinets remain unchanged.
Biosafety cabinet models Listed under NSF/ANSI 49 are approved for use with a power supply of 115V/60Hz, unless otherwise noted. If biosafety cabinets have been approved for use with additional power supplies, the power supply will be indicated in the Official Listing.
Across International LLC | ![]() |
111 Dorsa Avenue | |
Livingston, NJ 07039 | |
United States | |
888-988-0899 | |
Visit this company's website |
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
BC-2F[1] | A2 | A | 100 - 110 | 60 - 70 | N/A | 2 | 10S | 28 | U.V. Light Canopy Connection |
BC-3F[2] | A2 | A | 100 - 110 | 60 - 70 | N/A | 3 | 10S | 27 | Canopy Connection I.V. Pole U.V. Light |
BC-4F[3] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 27 | I.V. Pole U.V. Light Canopy Connection |
BC-4FB2[2] | B2 | A | 100 - 110 | 60 - 70 | 949 @ 2.1 | 4 | 8S | 27 | I.V. Pole U.V. Light |
BC-6F[4] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 27 | I.V. Pole Canopy Connection U.V. Light |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer's operator's manual for appropriate correction factor) without adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established with U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2020. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. Canopy connection model number is 2T-C. [2] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer's operator's manual for appropriate correction factor) without adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2016. Biobase canopy model CY-3FA2-I was evaluated as a part of the NSF Certification testing procedures. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. [3] Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. [4] Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. |
Allentown, LLC | ![]() |
Route 526 | |
Allentown, NJ 08501-0698 | |
United States | |
609-259-7951 | |
Visit this company's website |
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
39241[1] [2] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
39242xxx1 Safety Cab.[1] [3] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
39248[1] [2] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
39251[1] [2] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
39252xxx1 Safety Cab.[1] [4] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
39258[1] [2] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
39261[1] [2] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
39262xxx1 Safety Cab.[1] [3] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
39268[1] [2] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
[1] Certified for use with power supplies of 100V/50Hz, 100V/60Hz, 230V/50Hz, and 230V/60Hz. [2] Inflow nominal set point of 105 fpm was established with a direct airflow reading measurement. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted access opening, using the manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 55 fpm was established with I.V. pole and U.V. light removed. This cabinet model was Certified to NSF/ANSI 49-2012. This cabinet model is Certified for use with optional sidewall Vacu-PassTM Cord and Cable Portal. [3] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted access opening, using the manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 55 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2018. This cabinet model is Certified for use with optional sidewall Vacu-PassTM Cord & Cable Portal. [4] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted access opening, using the manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2018. This cabinet model is Certified for use with optional sidewall Vacu-PassTM Cord & Cable Portal. |
Baker Company, Inc. (The) | ![]() |
175 Gatehouse Road | |
Sanford, ME 04073 | |
United States | |
800-992-2537 | |
207-324-8773 | |
Visit this company's website |
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
BCG401[1] | B2 | C | 100 - 110 | 35 - 45 | 664 @ 1.6 | 4 | 8S | 35 | I.V. Pole U.V. Light Casters |
BCG601[1] | B2 | C | 100 - 110 | 35 - 45 | 993 @ 1.6 | 6 | 8S | 35 | I.V. Pole U.V. Light |
SG404[2] [3] [4] [5] | A2 | A | 100 - 110 | 47 - 57 42 - 52 |
N/A | 4 | 8S | 37 | I.V. Pole U.V. Light Casters Canopy Connection |
SG404[2] [3] [4] [5] | A2 | A | 100 - 110 | 47 - 57 42 - 52 |
N/A | 4 | 10S | 37 | I.V. Pole U.V. Light Casters Canopy Connection |
SG404[2] [3] [4] [5] | A2 | A | 100 - 110 | 47 - 57 42 - 52 |
N/A | 4 | 12S | 37 | I.V. Pole U.V. Light Casters Canopy Connection |
SG504[2] [3] [5] [6] | A2 | A | 100 - 110 | 45 - 55 42 - 52 |
N/A | 5 | 8S | 37 | I.V. Pole U.V. Light Casters Canopy Connection |
SG504[2] [3] [5] [6] | A2 | A | 100 - 110 | 45 - 55 42 - 52 |
N/A | 5 | 10S | 37 | I.V. Pole U.V. Light Casters Canopy Connection |
SG504[2] [3] [5] [7] | A2 | A | 100 - 110 | 45 - 55 40 - 50 |
N/A | 5 | 12S | 37 | I.V. Pole U.V. Light Casters Canopy Connection |
SG604[2] [3] [5] [8] | A2 | A | 100 - 110 | 48 - 58 42 - 52 |
N/A | 6 | 8S | 37 | Casters Canopy Connection I.V. Pole U.V. Light |
SG604[2] [3] [5] [8] | A2 | A | 100 - 110 | 48 - 58 42 - 52 |
N/A | 6 | 10S | 37 | Casters Canopy Connection I.V. Pole U.V. Light |
SG604[2] [3] [5] [9] | A2 | A | 100 - 110 | 42 - 52 36 - 46 |
N/A | 6 | 12S | 37 | Canopy Connection Casters I.V. Pole U.V. Light |
[1] Beginning with serial number 103539 for the 4-foot model and serial number 103706 for the 6-foot model. Inflow nominal setpoint of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate calculated method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer's operator's manual for appropriate correction factor), without adjusting cabinet airflow balance. Downflow nominal set point was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2010a. This cabinet qualifies only with the armrest installed. This cabinet is approved with additional petcocks on the sidewalls and a low static pressure exhaust plenum. Cabinet models BCG401 INT and BCG601 INT are Certified for alternate motor/blower combinations and input power supply. [2] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate calculated method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer's operator's manual for appropriate correction factor, if applicable). [3] Baker model designations SG404-AUS and SG604-AUS are Certified to NSF/ANSI 49-2012 for operation at 220V/50Hz with an 8-inch window opening. Baker model designations SG404-INT, SG504-INT, and SG604-INT are Certified to NSF/ANSI 49-2012 for operation at either 220V/50Hz or 220V/60Hz. [4] Beginning with serial number 110235. The acceptable non-uniform downflow ranges listed above begin with zone 1 (47-57 fpm) at the rear of the work area (compromised of lateral rear and center rows) and end with zone 2 (42-52 fpm) (comprised of front lateral row) behind the front window enclosing the work area. Downflow nominal set points were established with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2012. This cabinet qualifies only with the armrest installed. FlexAir Canopy connection 333A745 is approved for use with this model. [5] The maximum height for the bench stand with casters is 30 inches. The maximum height for the bench stand with feet is 37 inches. [6] Beginning with serial number 110795. The acceptable non-uniform downflow ranges listed above begin with zone 1 (45-55 fpm) at the rear of the work area (compromised of lateral rear and center rows) and end with zone 2 (42-52 fpm) (comprised of front lateral row) behind the front window enclosing the work area. Downflow nominal set points were established with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2012. This cabinet qualifies only with the armrest installed. FlexAir Canopy connection 336A745 is approved for use with this model. [7] Beginning with serial number 110795. The acceptable non-uniform downflow ranges listed above begin with zone 1 (45-55 fpm) at the rear of the work area (compromised of lateral rear and center rows) and end with zone 2 (40-50 fpm) (comprised of front lateral row) behind the front window enclosing the work area. Downflow nominal set points were established with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2012. This cabinet qualifies only with the armrest installed. FlexAir Canopy connection 336A745 is approved for use with this model. [8] Beginning with serial number 110555. The acceptable non-uniform downflow ranges listed above begin with zone 1 (48-58 fpm) at the rear of the work area (compromised of lateral rear and center rows) and end with zone 2 (42-52 fpm) (comprised of front lateral row) behind the front window enclosing the work area. Downflow nominal set points were established with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2012. This cabinet qualifies only with the armrest installed. FlexAir Canopy connection 336A745 is approved for use with this model. [9] Beginning with serial number 110555. The acceptable non-uniform downflow ranges listed above begin with zone 1 (42-52 fpm) at the rear of the work area (compromised of lateral rear and center rows) and end with zone 2 (36-46 fpm) (comprised of front lateral row) behind the front window enclosing the work area. Downflow nominal set points were established with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2012. This cabinet qualifies only with the armrest installed. FlexAir Canopy connection 336A745 is approved for use with this model. |
CHC Biotech Co., Ltd. | ![]() |
2nd Floor of W1 Building | |
150 Gwahakseongjang-ro | |
Yuseong-gu, Daejeon 305-500 | |
Korea, Republic of | |
82 42 936 5530 | |
Visit this company's website |
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
NB-704[1] [2] | A2 | A | 100 - 110 | 55 - 65 | 4 | 8S | 26 | I.V. Pole U.V. Light |
|
NB-706[1] [2] | A2 | A | 100 - 110 | 55 - 65 | 6 | 8S | 26 | I.V. Pole U.V. Light |
|
[1] Certified for use with power supplies of 115V/60 Hz, 230V/50 Hz and 230V/60 Hz. [2] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's alternate recommended method with thermal anemometer in a constricted (3 inch high) access opening consult manufacturer's operator's manual for appropriate correction factor), without adjusting cabinet airflow balance. Downflow nominal set point was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2020. This cabinet qualifies only with the armrest installed. |
Chung Fu Technical Development Co., Ltd. | ![]() |
7F, No. 687, Mintsu East Road | |
Taipei 105 | |
Taiwan | |
886 2 2600 1761 | |
Visit this company's website |
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
AHA-133-AA-B[1] [2] | A2 | A | 100 - 110 | 54 - 64 | N/A | 4 | 10S | 28 | I.V. Pole U.V. Light |
AHA-133-AB-B[1] [2] [3] | A2 | A | 100 - 110 | 54 - 64 | N/A | 4 | 10S | 28 | I.V. Pole U.V. Light |
AHA-133-AC-B[1] [2] [4] | A2 | A | 100 - 110 | 54 - 64 | N/A | 4 | 10S | 28 | I.V. Pole U.V. Light |
AHA-133-CA-B[1] [5] | A2 | A | 100 - 110 | 54 - 64 | N/A | 4 | 10S | 28 | I.V. Pole U.V. Light |
AHA-133-CB-B[1] [3] [5] | A2 | A | 100 - 110 | 54 - 64 | N/A | 4 | 10S | 28 | I.V. Pole U.V. Light |
AHA-133-CC-B[1] [4] [5] | A2 | A | 100 - 110 | 54 - 64 | N/A | 4 | 10S | 28 | I.V. Pole U.V. Light |
AHA-193-AA-A[2] [6] | A2 | A | 100 - 110 | 54 - 64 | N/A | 6 | 8S | 29 | I.V. Pole U.V. Light |
AHA-193-AB-A[2] [3] [6] | A2 | A | 100 - 110 | 54 - 64 | N/A | 6 | 8S | 29 | I.V. Pole U.V. Light |
AHA-193-AC-A[2] [4] [6] | A2 | A | 100 - 110 | 54 - 64 | N/A | 6 | 8S | 29 | I.V. Pole U.V. Light |
AHA-193-CA-A[5] [6] | A2 | A | 100 - 110 | 54 - 64 | N/A | 6 | 8S | 29 | I.V. Pole U.V. Light |
AHA-193-CB-A[3] [5] [6] | A2 | A | 100 - 110 | 54 - 64 | N/A | 6 | 8S | 29 | I.V. Pole U.V. Light |
AHA-193-CC-A[4] [5] [6] | A2 | A | 100 - 110 | 54 - 64 | N/A | 6 | 8S | 29 | I.V. Pole U.V. Light |
[1] Beginning with serial number AHA1608060. Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 59 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. Chung Fu Technical Development Co., Ltd. Models AHA-133-AA-B, AHA-133-AB-B, AHA-133-AC-B, AHA-133-CA-B, AHA-133-CB-B and AHA-133-CC-B are marketed by Air Science, LLC, USA as Air Science Models AS-AHA-133-AA-B, AS-AHA-133-AB-B, AS-AHA-133-AC-B, AS-AHA-133-CA-B, AS-AHA-133-CB-B and AS-AHA-133-CC-B, respectively. [2] Control panel is touch screen on this model. [3] Certified for use with power supplies of 230V/50Hz and 230V/60Hz. [4] Certified for use with power supplies of 100V/50Hz and 100V/60Hz. [5] Control panel is membrane switch on this model. [6] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. The downflow nominal set-point of 59 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2020. Chung Fu Technical Development Co., Ltd. Models AHA-193-AA-A, AHA-193-AB-A,AHA-193-AC-A, AHA-193-CA-A, AHA-193-CB-A and AHA-193-CC-A are marketed by Air Science, LLC, USA as Air Science Models AS-AHA-193-AA-A, AS-AHA-193-AB-A, AS-AHA-193-AC-A, AS-AHA-193-CA-A, AS-AHA-193-CB-A and AS-AHA-193-CC-A, respectively. |
Design Filtration Microzone Inc. | |
86 Harry Douglas Drive | |
Ottawa, ON K2S 2C7 | |
Canada | |
613-831-8318 | |
Visit this company's website |
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
BK-3-4[1] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 27 | Canopy Connection I.V. Pole U.V. Light |
BK-3-6[2] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 27 | I.V. Pole U.V. Light Canopy Connection |
BK3-4[3] [4] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 8S | 27 | I.V. Pole U.V. Light |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set point of 65 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. [2] Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. [3] Approved for alternate power modes of 220V/50Hz and 220V/60Hz. [4] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set-point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set-point of 65 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2012. |
Esco Micro Pte Ltd | ![]() |
21 Changi South Street 1 | |
486777 | |
Singapore | |
65 6542 0833 | |
Visit this company's website |
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
AC2-3E8-NS G4 8"[1] [2] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-3E9-NS G4 8"[1] [3] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-3J7 G4 8"[1] [4] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-3N7 G4 8" [1] [4] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-3S8-NS G4 8"[1] [2] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-3S9-NS G4 8"[1] [3] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-3Y7 G4 8"[1] [4] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-4E8-NS G4 10"[2] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-4E8-NS G4 8"[2] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-4E9-NS G4 10"[3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-4E9-NS G4 8" [3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-4J7 G4 10"[4] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-4J7 G4 8"[4] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-4N7 G4 10"[4] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-4N7 G4 8"[4] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-4S8-NS G4 10"[2] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-4S8-NS G4 8"[2] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-4S9-NS G4 10"[3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-4S9-NS G4 8"[3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-4Y7 G4 10"[4] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-4Y7 G4 8"[4] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-5E8-NS G4 8"[2] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-5E9-NS G4 8"[3] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-5J7 G4 8" [4] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-5N7 G4 8"[4] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-5S8-NS G4 8"[2] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-5S9-NS G4 8"[3] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-5Y7 G4 8"[4] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-6E8-NS G4 10"[2] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-6E8-NS G4 8"[2] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-6E9-NS G4 10"[3] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-6E9-NS G4 8"[3] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-6J7 G4 10"[4] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-6J7 G4 8"[4] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-6N7 G4 10"[4] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-6N7 G4 8"[4] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-6S8-NS G4 10" [2] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-6S8-NS G4 8"[2] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-6S9-NS G4 10"[3] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-6S9-NS G4 8"[3] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-6Y7 G4 10"[4] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AC2-6Y7 G4 8"[4] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-3E8 G4 8"[1] [2] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-3E9 G4 8"[1] [3] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-3S8 G4 8"[1] [2] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-3S9 G4 8"[1] [3] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-4E8 G4 10"[2] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-4E8 G4 8"[2] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-4E9 G4 10"[3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-4E9 G4 8"[3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-4S8 G4 10"[2] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-4S8 G4 8"[2] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-4S9 G4 10"[3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-4S9 G4 8"[3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-5E8 G4 8"[2] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-5E9 G4 8"[3] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-5S8 G4 8"[2] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-5S9 G4 8"[3] [6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-6E8 G4 10"[2] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-6E8 G4 8"[2] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-6E9 G4 10"[3] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-6E9 G4 8"[3] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-6S8 G4 10"[2] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-6S8 G4 8"[2] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-6S9 G4 10"[3] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
AR2-6S9 G4 8"[3] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-4J7 G4 10"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-4J7 G4 12"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light |
LA2-4J7 G4 8"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light |
LA2-4N7 G4 10"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-4N7 G4 12"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light |
LA2-4N7 G4 8"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light |
LA2-4S8 G4 10"[2] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-4S8 G4 12"[2] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light |
LA2-4S8 G4 8"[2] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light |
LA2-4S9 G4 10"[3] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-4S9 G4 12"[3] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light |
LA2-4S9 G4 8"[3] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light |
LA2-4Y7 G4 10"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-4Y7 G4 12"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light |
LA2-4Y7 G4 8"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light |
LA2-5J7 G4 10"[4] [9] | A2 | A | 100 - 110 | 60 - 70 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-5N7 G4 10"[4] [9] | A2 | A | 100 - 110 | 60 - 70 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-5S8 G4 10"[2] [9] | A2 | A | 100 - 110 | 60 - 70 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-5S9 G4 10"[3] [9] | A2 | A | 100 - 110 | 60 - 70 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-5Y7 G4 10"[4] [9] | A2 | A | 100 - 110 | 60 - 70 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-6J7 G4 10"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-6J7 G4 12"[4] [10] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-6N7 G4 10"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-6N7 G4 12"[4] [10] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-6S8 G4 10"[2] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-6S8 G4 12"[2] [10] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-6S9 G4 10"[3] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-6S9 G4 12"[3] [10] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-6Y7 G4 10"[4] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LA2-6Y7 G4 12"[4] [10] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
LB2-4B7 G4[4] [11] | B2 | A | 100 - 110 | 55 - 65 | 887 @ 1.9 | 4 | 8S | 35 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
LB2-4B8 G4[2] [11] | B2 | A | 100 - 110 | 55 - 65 | 887 @ 1.9 | 4 | 8S | 35 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
LB2-4B9 G4[3] [11] | B2 | A | 100 - 110 | 55 - 65 | 887 @ 1.9 | 4 | 8S | 35 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
LB2-4Y7 G4[4] [11] | B2 | A | 100 - 110 | 55 - 65 | 887 @ 1.9 | 4 | 8S | 35 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
LB2-4Y8 G4[2] [11] | B2 | A | 100 - 110 | 55 - 65 | 887 @ 1.9 | 4 | 8S | 35 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
LB2-4Y9 G4[3] [11] | B2 | A | 100 - 110 | 55 - 65 | 887 @ 1.9 | 4 | 8S | 35 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
LB2-6B7 G4[4] [12] | B2 | A | 100 - 110 | 55 - 65 | 1276 @ 2.7 | 6 | 8S | 34 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
LB2-6B8 G4[2] [12] | B2 | A | 100 - 110 | 55 - 65 | 1276 @ 2.7 | 6 | 8S | 34 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
LB2-6B9 G4[3] [12] | B2 | A | 100 - 110 | 55 - 65 | 1276 @ 2.7 | 6 | 8S | 34 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
LB2-6Y7 G4[4] [12] | B2 | A | 100 - 110 | 55 - 65 | 1276 @ 2.7 | 6 | 8S | 34 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
LB2-6Y8 G4[2] [12] | B2 | A | 100 - 110 | 55 - 65 | 1276 @ 2.7 | 6 | 8S | 34 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
LB2-6Y9 G4[3] [12] | B2 | A | 100 - 110 | 55 - 65 | 1276 @ 2.7 | 6 | 8S | 34 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
LR2-4S8 G4 10"[2] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LR2-4S8 G4 12"[2] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light |
LR2-4S8 G4 8"[2] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light |
LR2-4S9 G4 10"[3] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LR2-4S9 G4 12"[3] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light |
LR2-4S9 G4 8"[3] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light |
LR2-5S8 G4 10"[2] [9] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LR2-5S9 G4 10"[3] [9] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LR2-6S8 G4 10"[2] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LR2-6S8 G4 12"[2] [10] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
LR2-6S9 G4 10"[3] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
LR2-6S9 G4 12"[3] [10] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
VA2-4S8 G4 12"[2] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light |
VA2-4S9 G4 12"[3] [8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light |
VA2-6S8 G4 12"[2] [10] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
VA2-6S9 G4 12"[3] [10] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2022. [2] Certified for use with a power supply of 230V/50Hz and 230V/60Hz. [3] Certified for use with a power supply of 110V-120V/50Hz and 110V-120V/60Hz. [4] Approved for alternate power modes of 100V/50Hz and 100V/60Hz. [5] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2022. [6] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2022. [7] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2022. [8] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. [9] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. [10] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 70 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. [11] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2020. [12] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2022. |
Germfree Laboratories, Inc. | ![]() |
4 Sunshine Boulevard | |
Ormond Beach, FL 32174 | |
United States | |
386-265-4360 | |
Visit this company's website |
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
BSCA-4 | A2 | A | 100 - 110 | 54 - 64 54 - 64 40 - 50 |
N/A | 4 | 10S | 32 | I.V. Pole |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. The acceptable non-uniform downflow ranges listed above begin with zone 1 (54-64 fpm) closest to the back wall of the cabinet, zone 2 (54-64 fpm) center of the cabinet, and end with zone 3 (40-50 fpm) closest to the front sliding window. Downflow nominal set points were established with the I.V. Pole removed. This cabinet model was Certified to NSF/ANSI 49-2020. This cabinet qualifies only with the armrest installed. Certified for use with a power supply of 100V/50Hz/60Hz and 230V/50Hz/60Hz. Additional options are I.V. pole, casters and modified-passthrough.
Jinan Biobase Biotech Co., Ltd. | ![]() |
North side of Jiwang Road, Mingshui | |
Economic Dev. Zone, Zhangqiu Jinan | |
Shandong Province 250200 | |
China | |
86 531 5867 3159 | |
Visit this company's website |
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
BSC-2FA2-GL[1] | A2 | A | 100 - 110 | 60 - 70 | N/A | 2 | 10S | 28 | U.V. Light Canopy Connection |
BSC-2FA2-NA[1] | A2 | A | 100 - 110 | 60 - 70 | N/A | 2 | 10S | 28 | U.V. Light Canopy Connection |
BSC-3FA2-GL[2] | A2 | A | 100 - 110 | 60 - 70 | N/A | 3 | 10S | 27 | Canopy Connection I.V. Pole U.V. Light |
BSC-3FA2-NA[2] | A2 | A | 100 - 110 | 60 - 70 | N/A | 3 | 10S | 27 | Canopy Connection I.V. Pole U.V. Light |
BSC-4FA2[3] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 8S | 27 | I.V. Pole U.V. Light |
BSC-4FA2-GL[4] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 27 | I.V. Pole U.V. Light Canopy Connection |
BSC-4FA2-NA[4] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 27 | I.V. Pole U.V. Light Canopy Connection |
BSC-4FB2-GL[5] | B2 | A | 100 - 110 | 60 - 70 | 949 @ 2.1 | 4 | 8S | 27 | I.V. Pole U.V. Light |
BSC-4FB2-NA[5] | B2 | A | 100 - 110 | 60 - 70 | 949 @ 2.1 | 4 | 8S | 27 | I.V. Pole U.V. Light |
BSC-6FA2-GL[6] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 27 | I.V. Pole Canopy Connection U.V. Light |
BSC-6FA2-NA[6] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 27 | I.V. Pole Canopy Connection U.V. Light |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer's operator's manual for appropriate correction factor) without adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2020. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. Canopy connection model number is 2FT-CC. [2] Beginning with serial number 3FA18060001. Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer's operator's manual for appropriate correction factor) without adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2016. Biobase canopy model CY-3FA2-I was evaluated as a part of the NSF Certification testing procedures. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. [3] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set point of 65 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2012. Approved for alternate power modes of 115V/60Hz, 220V/50Hz and 220V/60Hz. [4] Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. [5] Beginning with serial number 4FB18050001. Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer's operator's manual for appropriate correction factor) without adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2016. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. [6] Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. |
Kewaunee Scientific Corporation | ![]() |
2700 West Front Street | |
Statesville, NC 28677 | |
United States | |
704-873-7202 | |
Visit this company's website |
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
INT-B1400-2[1] [2] | B2 | A | 100 - 110 | 55 - 65 | 937@2.4 | 4 | 8S | 36 | I.V. Pole U.V. Light |
INT-B2000-2[1] [2] | B2 | A | 100 - 110 | 55 - 65 | 1416@2.0 | 6 | 8S | 36 | I.V. Pole U.V. Light |
[1] Also Certified for use with power supplies of 230V/50Hz and 230V/60Hz. Model numbers may be followed by -230 suffix. [2] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2016. |
Labconco Corporation | ![]() |
8845 Prospect | |
Kansas City, MO 64132 | |
United States | |
816-333-8811 X771 | |
Visit this company's website |
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
30231xxx1 Logic+[1] [2] | A2 | A | 100 - 110 | 50 - 60 | N/A | 3 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
30238xxx1 Logic+[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Canopy Connection |
30241xxx1 Logic+[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
30242xxx1 Logic+[3] [4] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
30248xxx1 Logic+[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
30251xxx1 Logic+[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
30252xxx1 Logic+[3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
30258xxx1 Logic+[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
30261xxx1 Logic+[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
30262xxx1 Logic+[3] [4] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
30268xxx1 Logic+[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 8S | 36 | Canopy Connection I.V. Pole U.V. Light |
30348xxx1 Logic+[1] [3] | B2 | A | 100 - 110 | 50 - 60 | 852 @ 1.8 | 4 | 8S | 36 | Bag-In/ Bag-Out I.V. Pole U.V. Light |
30368xxx1 Logic+[1] [3] | B2 | A | 100 - 110 | 50 - 60 | 1265 @ 2.2 | 6 | 8S | 36 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
30448xxx1 Axiom[3] [6] | C1 | A | 100 - 110 | 60 - 70 | N/A | 4 | 8S | 36 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
30441xxx1 Axiom[3] [6] | C1 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
30468xxx1 Axiom[3] [4] | C1 | A | 100 - 110 | 50 - 60 | N/A | 6 | 8S | 36 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
30461xxx1 Axiom[3] [6] | C1 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
31231xxx1 PuriCare[1] [2] | A2 | A | 100 - 110 | 50 - 60 | N/A | 3 | 10S | 36 | I.V. Pole U.V. Light Canopy Connection |
31241xxx1 PuriCare[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
31242xxx1 PuriCare[3] [4] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 12S | 36 | I.V. Pole U.V. Light Canopy Connection |
31251xxx1 PuriCare[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
31252xxx1 PuriCare[3] [7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
31261xxx1 PuriCare[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 10S | 36 | Canopy Connection I.V. Pole U.V. Light |
31262xxx1 PuriCare[3] [4] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 12S | 36 | Canopy Connection I.V. Pole U.V. Light |
[1] Beginning with serial number 190500000. Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted access opening, using the manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 55 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2016. This cabinet model is Certified for use with optional sidewall Vacu PassTM Cord & Cable Portal. [2] Certified for use with power supplies of 230V/50 Hz and 230V/60 Hz. [3] Certified for use with power supplies of 100V/50 Hz, 100V/60 Hz, 230V/50 Hz, and 230V/60 Hz. [4] Beginning with serial number 151200002. Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted access opening, using the manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. This cabinet model is Certified for use with optional sidewall Vacu-PassTM Cord & Cable Portal. [5] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted access opening, using the manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 55 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2018. This cabinet model is Certified for use with optional sidewall Vacu-PassTM Cord & Cable Portal. [6] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted access opening, using the manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2018. This cabinet model is Certified for use with optional sidewall Vacu-PassTM Cord & Cable Portal. [7] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted access opening, using the manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2018. This cabinet model is Certified for use with optional sidewall Vacu-PassTM Cord & Cable Portal. |
NOTE: Bench stand models 3730300, 3730310, 3401003, 3780200 and 3780100 may be used with cabinets in the 30231xxx1/30238xxx1 Logic+ series. Bench stand models 3730400, 3730410, 3401004, 3780201 and 3780101 may be used with cabinets in the 30241xxx1/30248xxx1/30242 Logic+ series and the corresponding PuriCare series. Bench stand models 3730500, 3730510, 3401005, 3780203, 3780106, 3780107, 3780312, and 3780316 may be used with cabinets in the 30251xxx1/30258xxx1 Logic+ series. Bench stand models 3730600, 3630610, 3401006, 3780202 and 3780102 may be used with cabinets in the 30261xxx1/30268xxx1/30262 Logic+ series and the corresponding PuriCare series. Bench stand models 3730400 and 34103003 may also be used with the 30348xxx1 Logic+ Series. Bench stand models 3730600 and 34103006 may also be used with the 30368xxx1 Logic+ Series. All bench stand models beginning with 378 may be used with or without the optional wheel kit (PN# 3784000).
MEDFUTURE LLC | ![]() |
3231 Osgood Common | |
Freemont, CA 94539 | |
United States | |
626-283-4740 | |
Visit this company's website |
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
B-IIA2-2F-GL[1] | A2 | A | 100 - 110 | 60 - 70 | N/A | 2 | 10S | 28 | U.V. Light Canopy Connection |
B-IIA2-2F-NA[1] | A2 | A | 100 - 110 | 60 - 70 | N/A | 2 | 10S | 28 | U.V. Light Canopy Connection |
B-IIA2-4F[2] [3] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 8S | 27 | I.V. Pole U.V. Light |
B-IIA2-4F-GL[4] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 27 | I.V. Pole U.V. Light Canopy Connection |
B-IIA2-4F-NA[4] | A2 | A | 100 - 110 | 60 - 70 | N/A | 4 | 10S | 27 | I.V. Pole U.V. Light Canopy Connection |
B-IIA2-6F-GL[5] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 27 | I.V. Pole U.V. Light Canopy Connection |
B-IIA2-6F-NA[5] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 10S | 27 | I.V. Pole U.V. Light Canopy Connection |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer's operator's manual for appropriate correction factor) without adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established with U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2020. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. Canopy connection model number is 2A2T-CC. [2] Approved for alternate power modes of 220V/50Hz and 220V/60Hz. [3] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set point of 65 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2012. [4] Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. [5] Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal setpoint of 65 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. |
Nuaire, Inc. | ![]() |
2100 Fernbrook Lane | |
Plymouth, MN 55447 | |
United States | |
763-553-1270 | |
Visit this company's website |
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
NU-427-400[1] [2] [3] | B1 | A | 100 - 110 | 65 - 75 | 282 @ 0.7 | 4 | 8S | 32 | Bag-In/ Bag-Out I.V. Pole U.V. Light |
NU-427-600[1] [2] [4] | B1 | A | 100 - 110 | 65 - 75 | 474 @ 0.9 | 6 | 8S | 32 | I.V. Pole U.V. Light Bag-In/ Bag-Out |
NU-540-300[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-540-300[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-540-400[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-540-400[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-540-500[5] | A2 | A | 100 - 110 | 57 - 67 | N/A | 5 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-540-500[5] | A2 | A | 100 - 110 | 57 - 67 | N/A | 5 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-540-600[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-540-600[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-543-300[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-543-300[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-543-300[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 12S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-543-400[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-543-400[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-543-400[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-543-500[5] | A2 | A | 100 - 110 | 57 - 67 | N/A | 5 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-543-500[5] | A2 | A | 100 - 110 | 57 - 67 | N/A | 5 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-543-500[5] | A2 | A | 100 - 110 | 57 - 67 | N/A | 5 | 12S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-543-600[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 35 | U.V. Light I.V. Pole Canopy Connection |
NU-543-600[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-543-600[5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 12S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-545-300[6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-545-300[6] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-545-400[7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-545-400[7] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-545-500[8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-545-500[8] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-545-600[9] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-545-600[9] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 35 | I.V. Pole U.V. Light Canopy Connection |
NU-560-400[10] | B2 | A | 100 - 110 | 55 - 65 | 859@1.8 | 4 | 8S | 36 | I.V. Pole U.V. Light |
NU-560-600[11] | B2 | A | 100 - 110 | 55 - 35 | 1373@2.0 | 6 | 8S | 36 | I.V. Pole U.V. Light |
NU-565-400[10] | B2 | A | 100 - 110 | 55 - 65 | 859@1.8 | 4 | 8S | 36 | I.V. Pole U.V. Light |
NU-565-600[11] | B2 | A | 100 - 110 | 55 - 65 | 1373@2.0 | 6 | 8S | 36 | I.V. Pole U.V. Light |
NU-677-400[12] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 12S | 38 | Canopy Connection U.V. Light |
NU-677-500[13] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 12S | 38 | Canopy Connection U.V. Light |
NU-677-600[14] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 12S | 38 | Canopy Connection U.V. Light |
NU-FH677-500[15] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 12S | 38 | U.V. Light |
[1] Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening for appropriate correction factor, if applicable, without adjusting cabinet airflow balance. [2] Listed model may be suffixed with E. Certified for use with power supplies of 230V/50Hz and 230V/60Hz. [3] Beginning with Series 60 and higher. Downflow nominal set-point of 70 fpm was established 4 inches above the plane of the window with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2011. This cabinet qualifies with the optional DC motor installed. Listed model may be prefaced with Q, N, L or S (i.e. NU-Q427-400). [4] Beginning with series 40 and higher. Downflow nominal set-point of 60 fpm was established 4 inches above the plane of the window with the I.V. Pole and U.V. Light removed. This cabinet qualifies with the optional DC motor installed. Listed model may be prefaced with Q, N, L or S (i.e. NU-Q427-600). This cabinet model was Certified to NSF/ANSI 49-2011. [5] Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 60 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2012. Listed model may be prefaced with Q, N, L, or S (e.g. NU-Q540-300). Certified for use with power supplies of 100V/50Hz, 100V/60Hz, 230V/50Hz, and 230V/60Hz. [6] Beginning with serial number 170844102115. Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 60 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. Listed model may be prefaced with Q, N, L, or S (e.g. NU-Q540-300). Certified for use with power supplies of 100V/50Hz, 100V/60Hz, 230V/50Hz, and 230V/60Hz. [7] Beginning with serial number 170847102115. Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 60 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2020. Listed model may be prefaced with Q, N, L, or S (e.g. NU-Q540-300). Certified for use with power supplies of 100V/50Hz, 100V/60Hz, 230V/50Hz, and 230V/60Hz. [8] Beginning with serial number 170845102115. Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 60 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. Listed model may be prefaced with Q, N, L, or S (e.g. NU-Q540-300). Certified for use with power supplies of 100V/50Hz, 100V/60Hz, 230V/50Hz, and 230V/60Hz. [9] Beginning with serial number 170846102115. Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 60 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. Listed model may be prefaced with Q, N, L, or S (e.g. NU-Q540-300). Certified for use with power supplies of 100V/50Hz, 100V/60Hz, 230V/50Hz, and 230V/60Hz. [10] Beginning with serial number 179773041817. Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 60 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2016. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. The concurrent balance value was taken with the NSF exhaust system conforming to ASHRAE. However, differences due to the exhaust system, cabinet and instrumentation may be present and product specification information should be obtained from the manufacturer. [11] Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 60 fpm was established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2016. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. The concurrent balance value was taken with the NSF exhaust system conforming to ASHRAE. However, differences due to the exhaust system, cabinet and instrumentation may be present and product specification information should be obtained from the manufacturer. [12] Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 60 fpm was established 4 inches above the bottom of the sash with the U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2011. NuAire canopy model NU-911-402 was evaluated as part of the NSF Certification testing procedures. [13] Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 60 fpm was established 4 inches above the bottom of the sash with the U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2011. NuAire canopy model NU-911-502 was evaluated as a part of the NSF Certification testing procedures. [14] Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 60 fpm was established 4 inches above the bottom of the sash with the U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2011. NuAire canopy model NU-911-602 was evaluated as part of the NSF Certification testing procedures. [15] Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 60 fpm was established 4 inches above the bottom of the sash with the U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2012. NuAire canopy model NU-911-502 was evaluated as a part of the NSF Certification testing procedures. NU-FH677-500 is a modified version of NU-677-500, including feed hoppers. |
Facility : Shanghai, China
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
NU-543-300[1] | A2 | A | 100 - 110 | 55 - 65 | N/A | 3 | 10S | 35 | Canopy Connection I.V. Pole U.V. Light |
NU-543-400[1] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 35 | Canopy Connection I.V. Pole U.V. Light |
NU-543-500[2] | A2 | A | 100 - 110 | 57 - 67 | N/A | 5 | 10S | 35 | Canopy Connection I.V. Pole U.V. Light |
NU-543-600[1] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 35 | Canopy Connection I.V. Pole U.V. Light |
[1] Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 60 fpm was established 4 inches above the bottom of the sash with the I.V. pole and U.V. light removed. This cabinet model was Certified to NSF 49-2012. Listed model may be prefaced with Q, N, L, or S (e.g. NU-Q540-300). Listed model may be suffixed with J, K, or S (e.g. NU-543-400S). Certified for use with power supplies of 100V/50Hz, 100V/60Hz, 230V/50Hz, and 230V/60Hz. [2] Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 62 fpm was established 4 inches above the bottom of the sash with the I.V. pole and U.V. light removed. This cabinet model was Certified to NSF 49-2012. Listed model may be prefaced with Q, N, L, or S (e.g. NU-Q540-300). Listed model may be suffixed with J, K, or S (e.g. NU-543-400S). Certified for use with power supplies of 100V/50Hz, 100V/60Hz, 230V/50Hz, and 230V/60Hz. |
Qingdao Haier Biomedical Co., Ltd. | ![]() |
No. 280 Fengyuan Road | |
High-Tech Zone | |
Qingdao 266111 | |
China | |
86 176 6092 6003 | |
Visit this company's website |
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
HR900-IIA2-N[1] [2] | A2 | A | 100 - 110 | 64 - 74 | N/A | 3 | 8S | 27 | U.V. Light Casters Hgt Adjustable Stand |
HR1200-IIA2-N[1] [3] | A2 | A | 100 - 110 | 64 - 74 | N/A | 4 | 8S | 27 | U.V. Light Casters Hgt Adjustable Stand |
HR1800-IIA2-N[1] [4] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 8S | 27 | U.V. Light Casters Hgt Adjustable Stand |
[1] This cabinet model was Certified for use with power supplies of 100V/60Hz, 115V/60Hz, 230V/50Hz, 230V/60Hz [2] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 69 fpm was established U.V. Light removed. This cabinet is Certified to NSF/ANSI 49-2022. GFCI outlet is approved for this model. [3] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 69 fpm was established U.V. Light removed. This cabinet is Certified to NSF/ANSI 49-2019. GFCI outlet is approved for this model. [4] Beginning with serial number BE0GGBEB200QHM7P0001. Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 70 fpm was established U.V. Light removed. This cabinet is Certified to NSF/ANSI 49-2019. |
Shanghai Lishen Scientific Equipment Co., Ltd. | ![]() |
No. 6788 SongZe Avenue | |
QingPu, Shanghai | |
201706 | |
China | |
86 215 986 7888 | |
Visit this company's website |
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
HFsafe-1200LC A2[1] | A2 | A | 100 - 110 | 64 - 74 | N/A | 4 | 8S | 27 | U.V. Light |
HFsafe-1200LC N[1] [2] | A2 | A | 100 - 110 | 64 - 74 | N/A | 4 | 8S | 27 | U.V. Light |
[1] Beginning with serial number 051312LCJ0003EUS. Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (80 mm high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow Certified to NSF/ANSI 49-2018. Approved metric value for cabinet width is 1250 mm, window height is 200 mm, and bench height max is 690 mm. [2] Approved for alternate power mode of 230V/50Hz. |
Suzhou Antai Airtech Co., Ltd. | ![]() |
No. 2 Weixin Road, SIP | |
Suzhou, Jiangsu 215122 | |
China | |
86 512 6552 5002 | |
Visit this company's website |
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
BSC-1301 II A2[1] | A2 | A | 100 - 110 | 64 - 74 | N/A | 4 | 10S | 24 | U.V. Light Canopy Connection |
BSC-1302 II A2[1] [2] | A2 | A | 100 - 110 | 64 - 74 | N/A | 4 | 10S | 24 | U.V. Light Canopy Connection |
[1] Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's recommended alternate method with thermal anemometer in a constricted (80 mm high) access opening and applying appropriate correction factor without adjusting cabinet airflow balance. The downflow nominal set-point of 69 fpm was established 4 inches above the bottom of the sash with the U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. Approved metric value for cabinet width is 1270 mm, window height is 250 mm, and bench height max is 610 mm. [2] Certified for use with power supplies of 230V/50Hz and 230V/60Hz. |
Thermo Fisher Scientific | |
Robert-Bosch-Str. 1 | |
D-63505 Langenselbold | |
Germany | |
49 61 813 5277 | |
Visit this company's website |
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
1304[1] [2] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1309[1] [2] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | S | Armrest I.V. Pole U.V. Light |
1374[1] [2] [3] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1379[1] [2] [4] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1384[1] [2] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1389[1] [2] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1394[1] [2] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1399[1] [2] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1574[5] [6] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1579[5] [6] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1584[5] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1589[5] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
[1] Models can be provided with Type F power cord and internal receptacles and identified as 1304-F, 1309-F, 1374-F, 1379-F, 1384-F, 1389-F, 1394-F, or 1399-F; with Type G power cord and internal receptacles and identified as 1304-G, 1309-G, 1374-G, 1379-G, 1384-G, 1389- G, 1394-G, or 1399-G; with Type M power cord and internal receptacles and identified as 1304-M, 1309-M, 1374-M, 1379-M, 1384-M, 1389-M, 1394-M, or 1399-M; or with the standard Type I power cord and internal receptacles. [2] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set-point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set-point of 63 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014. Certified for use with power supplies of 220V/50Hz and 220V/60Hz. [3] Beginning with serial number 1374318010704. [4] Beginning with serial number 1379318010304. [5] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set-point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set-point of 63 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2020. Certified for use with power supplies of 230V/50Hz and 230V/60Hz. Removable armrests with padded and non-padded designs in addition to dished and flat work surface designs are approved options for this cabinet model. [6] This model includes stainless steel interior cabinet walls with adjustable height stand. Model can be provided with the standard Type I power cord and internal receptacles (China electrical configuration with YY certification) and identified as 1574, and 1579; with Type GP power cord and internal receptacles (China electrical configuration without YY certification) and identified as 1574-GP, 1579-GP; with Type F power cord and internal receptacles (Korea electrical configuration) and identified as 1574-F, 1579-F; with Type G power cord and internal receptacles (UK electrical configuration) and identified as 1574-G, 1579-G; with Type M power cord and internal receptacles (India electrical configuration) and identified as 1574-M, 1579-M; or with Type C fixed height stand with castors and identified as 1574-C, 1579-C, 1574-FC, 1579-FC, 1574-GC, 1579-GC, 1574-MC, 1579-MC, 1574-C-GP, 1579-C-GP. 1546 and 1548 are the same models as 1574 and 1579 without stands. [7] This model includes coated steel (SmartCoat)interior cabinet walls with adjustable height stand. Model can be provided with the standard Type I power cord and internal receptacles (China electrical configuration with YY certification) and identified as 1584, 1589; with Type F power cord and internal receptacles (Korea electrical configuration)and identified as 1584-F, 1589-F; with Type G power cord and internal receptacles (UK electrical configuration) and identified as 1584-G, 1589-G; with Type M power cord and internal receptacles (India electrical configuration) and identified as 1584-M, 1589-M; or with Type C fixed height stand with castors and identified as 1584-C, 1589-C, 1584-FC, 1589-FC, 1584-GC, 1589-GC, 1584-MC, 1589-MC. 1556 and 1558 are the same models as 1584 and 1589 without stands. |
Facility : # 2 Suzhou, China
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
1574[1] [2] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1579[1] [2] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1584[1] [3] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1589[1] [3] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set-point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set-point of 63 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ ANSI 49-2020. Certified for use with power supplies of 230V/50Hz and 230V/60Hz. Removable armrests with padded and non-padded designs in addition to dished and flat work surface designs are approved options for this cabinet model. [2] This model includes stainless steel interior cabinet walls with adjustable height stand. Model can be provided with the standard Type I power cord and internal receptacles (China electrical configuration with YY certification) and identified as 1574, and 1579; with Type GP power cord and internal receptacles (China electrical configuration without YY certification) and identified as 1574-GP, 1579-GP; with Type F power cord and internal receptacles (Korea electrical configuration) and identified as 1574-F, 1579-F; with Type G power cord and internal receptacles (UK electrical configuration) and identified as 1574-G, 1579-G; with Type M power cord and internal receptacles (India electrical configuration) and identified as 1574-M, 1579-M; or with Type C fixed height stand with castors and identified as 1574-C, 1579-C, 1574-FC, 1579-FC, 1574-GC, 1579-GC, 1574-MC, 1579-MC, 1574-C-GP, 1579-C-GP. 1546 and 1548 are the same models as 1574 and 1579 without stands. [3] This model includes coated steel (SmartCoat)interior cabinet walls with adjustable height stand. Model can be provided with the standard Type I power cord and internal receptacles (China electrical configuration with YY certification) and identified as 1584, 1589; with Type F power cord and internal receptacles (Korea electrical configuration)and identified as 1584-F, 1589-F; with Type G power cord and internal receptacles (UK electrical configuration) and identified as 1584-G, 1589-G; with Type M power cord and internal receptacles (India electrical configuration) and identified as 1584-M, 1589-M; or with Type C fixed height stand with castors and identified as 1584-C, 1589-C, 1584-FC, 1589-FC, 1584-GC, 1589-GC, 1584-MC, 1589-MC. 1556 and 1558 are the same models as 1584 and 1589 without stands. |
Facility : Marietta, OH
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
1305[1] [2] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1306[1] [2] [3] | A2 | A | 100 - 110 | 58 - 58 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1307[1] [4] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1308[1] [3] [4] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1320[5] [6] [7] | A2 | B | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1321[5] [6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1322[5] [6] [7] | A2 | B | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1323[5] [6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest U.V. Light I.V. Pole |
1325[1] [2] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1326[1] [2] [3] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1327[1] [4] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1328[1] [3] [4] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1330[3] [5] [6] [7] | A2 | B | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1331[3] [5] [6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1332[3] [5] [6] [7] | A2 | B | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1333[3] [5] [6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1335[1] [2] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1336[1] [2] [3] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1337[1] [4] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1338[1] [3] [4] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1339[5] [6] [7] | A2 | B | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1340[5] [6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1341[5] [6] [7] | A2 | B | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1342[5] [6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1345[2] [8] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1346[2] [8] [9] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1347[4] [8] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1348[4] [8] [9] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1350[5] [6] [10] | A2 | B | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1351[5] [6] [10] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1352[5] [6] [10] | A2 | B | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1353[5] [6] [10] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1354[2] [11] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1355[2] [8] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1356[2] [8] [9] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1357[4] [8] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1358[4] [8] [9] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1359[4] [8] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1366[3] [5] [6] [10] | A2 | B | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1367[3] [5] [6] [10] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1368[5] [6] [10] | A2 | B | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1369[5] [6] [10] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest U.V. Light I.V. Pole |
1370[5] [6] [10] | A2 | B | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1371[5] [6] [10] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1372[3] [5] [6] [10] | A2 | B | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest U.V. Light I.V. Pole |
1373[3] [5] [6] [10] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1375[2] [8] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1376[2] [8] [9] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1377[4] [8] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1378[4] [8] [9] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1380[3] [5] [6] [10] | A2 | B | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1381[3] [5] [6] [10] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1382[3] [5] [6] [10] | A2 | B | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1383[3] [5] [6] [10] | A2 | A | 100 - 110 | 58 - 68 | N/A | 5 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1384[2] [11] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1385[2] [8] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1386[2] [8] [9] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1387[4] [8] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1388[4] [8] [9] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1389[4] [11] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
1390[3] [5] [6] [7] | A2 | B | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1391[3] [5] [6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1392[3] [5] [6] [7] | A2 | B | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1393[3] [5] [6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 3 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1395[2] [9] [12] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1396[1] [2] [3] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1397[4] [9] [12] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
1398[1] [3] [4] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 8S | 36 | Armrest I.V. Pole U.V. Light |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set-point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set-point of 63 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2009. [2] Beginning April 20, 2020 a new fixed height base stand GT221201 and adjustable height base stand GT221189 along with 4ft cross brace GT221195 were approved for use with all 1300 series models manufactured in Marietta OH. Casters GT221199 is an approved option for both stands. [3] Certified for use with power supply of 230V/50Hz and 230V/60Hz. [4] Beginning April 20, 2020 a new fixed height base stand GT221201 and adjustable height base stand GT221189 along with 6ft cross brace GT221196 were approved for use with all 1300 series models manufactured in Marietta OH. Casters GT221199 is an approved option for both stands. [5] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's alternate recomended method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer's operator's manual for appropriate correction factor), without adjusting cabinet airflow balance. Downflow nominal set point was established with I.V.Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2009. [6] May be used with alternate, adjustable height electric stand (maximum bench height of 35 inches). [7] Beginning April 20, 2020 a new fixed height base stand GT221201 and adjustable height base stand GT221189 along with 3ft cross brace GT221193 were approved for use with all 1300 series models manufactured in Marietta OH. Casters GT221199 is an approved option for both stands. [8] Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 63 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2009. Certified for use with power supply of 230V/50Hz and 230V/60Hz. [9] Certified for use with power supply of 220 V / 50 Hz and 220 V / 60 Hz. [10] Beginning April 20, 2020 a new fixed height base stand GT221201 and adjustable height base stand GT221189 along with 5ft cross brace GT221197 were approved for use with all 1300 series models manufactured in Marietta OH. Casters GT221199 is an approved option for both stands. [11] Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set-point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set-point of 63 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2009. Certified for use with power supply of 220V/50Hz. [12] Beginning with serial number 188122-1 and 188108-1 for models 1395 and 1397, respectively. Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 63 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2009. |
Facility : Langenselbold, Germany
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
HERAsafe 2030i 1.2[1] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
HERAsafe 2030i 1.8[1] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
[1] Beginning with serial number 42294669 for the HERAsafe 2030i 1.2 and serial number 42209172 for the HERAsafe 2030i 1.8. Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer's operator's manual for appropriate correction factor) without adjusting cabinet airflow balance. Downflow nominal set point of 63 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified with both dished and flat work surfaces and for additional inlet power supplies of 230V/50Hz and 230V/60Hz. This cabinet model was Certified to NSF/ANSI 49-2018. HERAsafe 2030i 1.2 is approved for use with either padded armrests or armrests without padding. HERAsafe 2030i 1.8 is approved for use without armrests, with padded armrests, or with armrests without padding. |
[2] Beginning with serial number 40329642. Inflow nominal set-point of 105 fpm was established with a direct airflow reading instrument. This nominal set-point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted (3 inch high) access opening (consult manufacturer's operator's manual for appropriate correction factor) without adjusting cabinet airflow balance. This cabinet model was Certified with a 3 section work surface. This cabinet model was Certified to NSF/ANSI 49-2009.
Thermo Fisher Scientific | |
401 Millcreek Road | |
Marietta, OH 45750 | |
United States | |
740-373-4763 |
Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
151x[1] [2] [3] | B2 | A | 100 - 110 | 50 - 60 | 852 @ 1.8 | 4 | 8S | 36 | Bag-In/ Bag-Out I.V. Pole U.V. Light |
156x[1] [2] [4] | B2 | A | 100 - 110 | 50 - 60 | 1265 @ 2.2 | 6 | 8S | 36 | Bag-In/ Bag-Out I.V. Pole U.V. Light |
[1] Beginning with serial number 190500000. Inflow nominal set point of 105 fpm was established with a direct airflow reading instrument. This nominal set point was confirmed using the manufacturer's recommended alternate method with thermal anemometer in a constricted access opening, using the manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate correction factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of 55 fpm was established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2016. This cabinet model is Certified for use with optional cord & cable portal. [2] Certified for use with power supplies of 100V/50 Hz, 100V/60 Hz, 230V/50 Hz, and 230V/60 Hz. [3] Model 1511 is equivalent to Model 1510, but comes equipped with U.V. lighting (Listed as an acceptable option). Model 1515 is equivalent to model 1510, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Chinese-compatible plug. Model 1516 is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with U.V. lighting and a Chinese-compatible plug. Model 1517 is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a North American 230 Volt-compatible plug. Model 1517F is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type F electrical plug (Schuko). Model 1517G is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type G electrical plug (UK-compatible). Model 1517M is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type M electrical plug (India-compatible). Model 1518 is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with U.V. lighting and a North American 230 Volt-compatible plug.Model 1518F is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type F electrical plug (Schuko). Model 1518G is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type G electrical plug (UK-compatible). Model 1518M is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type M electrical plug (India-compatible). [4] Model 1561 is equivalent to Model 1560, but comes equipped with U.V. lighting (Listed as an acceptable option). Model 1562 is equivalent to model 1560, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Chinese-compatible plug. Model 1563 is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with U.V. lighting and a Chinese-compatible plug. Model 1564 is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a North American 230 Volt-compatible plug. Model 1564F is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type F electrical plug (Schuko). Model 1564G is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type G electrical plug (UK-compatible). Model 1564M is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type M electrical plug (India-compatible). Model 1565 is equivalent, but is rated for use with power supplies of 230 V and 50/60 Hz and is equipped with U.V. lighting and a North American 230 Volt-compatible plug. Model 1565F is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type F electrical plug (Schuko). Model 1565G is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type G electrical plug (UK-compatible). Model 1565M is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type M electrical plug (India-compatible). |