NSF/ANSI 401
Drinking Water Treatment Units - Emerging Compounds/Incidental Contaminants
Drinking Water Treatment Units - Emerging Compounds/Incidental Contaminants
Kemflo / Filbur | |
No. 3 Huan East Street, Da-Zhou | |
Pingtung 900 | |
Taiwan | |
886 8 7524736 |
Facility : # 2 Pingtung, Taiwan
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Plumbed-In[G] |
||||||
KF-DWS-G | KF-DWS-G-R | 1500 | 1.5 | Atenolol Reduction Carbamazepine Reduction DEET Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Microplastics Reduction Trimethoprim Reduction |
||
KF-DWS-S | KF-DWS-S-R | 2000 | 2 | Microplastics Reduction | ||
  [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
COMPONENTS: Carbon Block[1] [G] |
||||||
KFRF-1135-0200-01[2] | ||||||
KFRF-1138-0120-2[3] | ||||||
KFRF-1138-0200-01[2] | ||||||
KFRF-1138-0240-02[2] | ||||||
  [1] Conforms to material requirements only. [2] Tested in a system at a flow rate of 0.75 gpm to a capacity of 200 gallons for the reduction of Atenolol, Trimethoprim, Linuron, Estrone, and Nonyl phenol per NSF/ANSI 401. Tested in a system at a flow rate of 0.75 gpm to a capacity of 180 gallons for the reduction of Bisphenol A per NSF/ANSI 401. Tested in a system at a flow rate of 0.75 gpm to a capacity of 182 gallons for the reduction of Carbamazepine per NSF/ANSI 401. Tested in a system at a flow rate of 0.50 gpm to a capacity of 240 gallons for the reduction of Atenolol, Estrone, Linuron, Nonyl phenol, Trimethoprim, Meprobamate, Carbamazepine, DEET, Metolachlor, TCEP, TCPP, Phenytoin, Ibuprofen, Microplastics Reduction, Naproxen, and Bisphenol A per NSF/ANSI 401. [3] Tested in a system at a flow rate of 0.5 GPM to a capacity of 200 gallons for the reduction of: - Chlorine, Particulate Class I, Taste and Odor per NSF/ANSI 42 - Asbestos, Atrazine, Benzene, Carbofuran, Cysts, Endrin, Ethylbenzene, Lead, Lindane, MTBE, Mercury, o-Dichlorobenzene, Tetrachloroethylene, Toxaphene, TTHM, Turbidity, VOC per NSF/ANSI 53 - Atenolol, Bisphenol A, Carbamazepine, DEET, Estrone, Ibuprofen, Linuron, Meprobamate, Metalachlor, Microplastics, Naproxen, Nonyl Phenol, Phenytoin, TCEP, TCPP, and Trimethoprim per NSF/ANSI 401 [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Number of matching Manufacturers is 1
Number of matching Products is 6