NSF Product and Service Listings
These NSF Official Listings are current as of Friday, October 24, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?Standard=401&Company=26000&
Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.
NSF/ANSI 401
Drinking Water Treatment Units - Emerging Compounds/Incidental Contaminants
Drinking Water Treatment Units - Emerging Compounds/Incidental Contaminants
| Kemflo / Filbur | |
| No. 3 Huan East Street, Da-Zhou | |
| Pingtung 900 | |
| Taiwan | |
| 886 8 7524736 |
Facility : # 2 Pingtung, Taiwan
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Plumbed-In[G] |
||||||
| KF-DWS-G | KF-DWS-G-R | 1500 | 1.5 | Atenolol Reduction Carbamazepine Reduction DEET Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Microplastics Reduction Trimethoprim Reduction |
||
| KF-DWS-S | KF-DWS-S-R | 2000 | 2 | Microplastics Reduction | ||
|
  [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
|
Replacement Element: Refrigerator Filter [G] |
||||||
| KF-WFC-CM[4] | N/A | 250(1) | .55 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Microplastics Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction |
||
| KF-WFC-CM[5] | N/A | 150(1) | .55 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Microplastics Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Trimethoprim Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[4] With PID
[5] Without PID
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
|
COMPONENTS: Carbon Block[1] [G] |
||||||
| KFRF-1135-0200-01[2] | ||||||
| KFRF-1138-0120-2[3] | ||||||
| KFRF-1138-0200-01[2] | ||||||
| KFRF-1138-0240-02[2] | ||||||
| KFRF-1138-0250-16[6] | ||||||
|
  [1] Conforms to material requirements only.
[2] Tested in a system at a flow rate of 0.75 gpm to a capacity of 200 gallons for the
reduction of Atenolol, Trimethoprim, Linuron, Estrone, and Nonyl phenol per NSF/ANSI
401.
Tested in a system at a flow rate of 0.75 gpm to a capacity of 180 gallons for the
reduction of Bisphenol A per NSF/ANSI 401.
Tested in a system at a flow rate of 0.75 gpm to a capacity of 182 gallons for the
reduction of Carbamazepine per NSF/ANSI 401.
Tested in a system at a flow rate of 0.50 gpm to a capacity of 240 gallons for the
reduction of Atenolol, Estrone, Linuron, Nonyl phenol, Trimethoprim, Meprobamate,
Carbamazepine, DEET, Metolachlor, TCEP, TCPP, Phenytoin, Ibuprofen, Microplastics
Reduction, Naproxen, and Bisphenol A per NSF/ANSI 401.
[3] Tested in a system at a flow rate of 0.5 GPM to a capacity of 200 gallons for the
reduction of:
- Chlorine, Particulate Class I, Taste and Odor per NSF/ANSI 42
- Asbestos, Atrazine, Benzene, Carbofuran, Cysts, Endrin, Ethylbenzene, Lead, Lindane,
MTBE, Mercury, o-Dichlorobenzene, Tetrachloroethylene, Toxaphene, TTHM, Turbidity, VOC
per NSF/ANSI 53 - Atenolol, Bisphenol A, Carbamazepine, DEET, Estrone, Ibuprofen,
Linuron, Meprobamate, Metalachlor, Microplastics, Naproxen, Nonyl Phenol, Phenytoin,
TCEP, TCPP, and
Trimethoprim per NSF/ANSI 401
[6] Tested in a system at a flow rate of 0.5 gpm to a capacity of 150 gallons for the
reduction of Atenolol, Bisphenol, Carbamazepine, DEET, Estrone, Ibuprofen, Linuron,
Meprobamate, Metolachlor, Microplastics, Naproxen, Nonylphenol, Phenytoin, and
Trimethoprim per NSF/ANSI 401.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Number of matching Manufacturers is 1
Number of matching Products is 9
Processing time was 0 seconds

