These NSF Official Listings are current as of Thursday, December 12, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?Standard=401&Company=26000&

Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.


NSF/ANSI 401
Drinking Water Treatment Units - Emerging Compounds/Incidental Contaminants



 
Kemflo / Filbur 
No. 3 Huan East Street, Da-Zhou
Pingtung 900 
Taiwan 
886 8 7524736

Facility : # 2 Pingtung, Taiwan

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In[G]
KF-DWS-G KF-DWS-G-R 1500 1.5   Atenolol Reduction
Carbamazepine Reduction
DEET Reduction
Linuron Reduction
Meprobamate Reduction
Metolachlor Reduction
Microplastics Reduction
Trimethoprim Reduction
KF-DWS-S KF-DWS-S-R 2000 2   Microplastics Reduction

   
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

COMPONENTS: Carbon Block[1] [G]
KFRF-1135-0200-01[2]  
KFRF-1138-0120-2[3]  
KFRF-1138-0200-01[2]  
KFRF-1138-0240-02[2]  

   
[1] Conforms to material requirements only.
[2] Tested in a system at a flow rate of 0.75 gpm to a capacity of 200 gallons for the
    reduction of Atenolol, Trimethoprim, Linuron, Estrone, and Nonyl phenol per NSF/ANSI
    401.
    Tested in a system at a flow rate of 0.75 gpm to a capacity of 180 gallons for the
    reduction of  Bisphenol A per NSF/ANSI 401.
    Tested in a system at a flow rate of 0.75 gpm to a capacity of 182 gallons for the
    reduction of Carbamazepine per NSF/ANSI 401.
    Tested in a system at a flow rate of 0.50 gpm to a capacity of 240 gallons for the
    reduction of Atenolol, Estrone, Linuron, Nonyl phenol, Trimethoprim, Meprobamate,
    Carbamazepine,  DEET, Metolachlor, TCEP, TCPP, Phenytoin, Ibuprofen, Microplastics
    Reduction, Naproxen, and Bisphenol A per NSF/ANSI 401.
[3] Tested in a system at a flow rate of 0.5 GPM to a capacity of 200 gallons for the
    reduction of:
    - Chlorine, Particulate Class I, Taste and Odor per NSF/ANSI 42
    - Asbestos, Atrazine, Benzene, Carbofuran, Cysts, Endrin, Ethylbenzene, Lead, Lindane,
    MTBE, Mercury, o-Dichlorobenzene, Tetrachloroethylene, Toxaphene, TTHM, Turbidity, VOC
    per NSF/ANSI 53 - Atenolol, Bisphenol A, Carbamazepine, DEET, Estrone, Ibuprofen,
    Linuron, Meprobamate, Metalachlor, Microplastics, Naproxen, Nonyl Phenol, Phenytoin,
    TCEP, TCPP, and
    Trimethoprim per NSF/ANSI 401
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Number of matching Manufacturers is 1
Number of matching Products is 6
Processing time was 0 seconds