NSF/ANSI 58
Reverse Osmosis Drinking Water Treatment Systems



 
Pentair Residential Filtration, LLC 
13845 Bishops Drive
Suite 200 
Brookfield, WI 53005 
United States 
800-279-9404 
262-238-4400

Facility : Hanover Park, IL

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap
Everpure Residential ROM IV[Pb] ROM-PRE
ROM-G75
ROM-PST
ROM-PFK
  14.66   Arsenic (Pentavalent)<=300 ppb Reduction*
Barium Reduction
Cadmium Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Chromium (Hexavalent) Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Chromium (Trivalent) Reduction
Turbidity Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


Facility : Roselle, IL

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap
Everpure Residential ROM IV[Pb] ROM-G75
ROM-PFK
ROM-PRE
ROM-PST
  14.66   Arsenic (Pentavalent)<=50 ppb Reduction*
Turbidity Reduction
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


Facility : Jiangsu Province, China

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap [Pb]
OmniFilter RO2050[1] [2] CB1
OM1
R200 Series A
ROR2000
RS14
ROR2050
  15.04   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
Pentair GRO-2550 GS10-RO
P5
EPM-10
GRO-50EN
  10.09   Cyst Reduction
TDS Reduction
Pentair GRO-2575 GRO-75EN   13.96   TDS Reduction
Pentair GRO-350B FDF1-RC
GRO50-RC
F1GC-RC
  14.96   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
Turbidity Reduction
TDS Reduction
Nitrate/Nitrite Reduction
Pentair GRO-350BP FDF1-RC
GRO50-RC
F1GC-RC
  99.08   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
Turbidity Reduction
TDS Reduction
Pentair GRO-475B FDF1-RC
GRO75-RC
F1B1-RC
F1GC-RC
  21.08   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
Turbidity Reduction
TDS Reduction
Pentair GRO-475BP FDF1-RC
GRO75-RC
F1B1-RC
F1GC-RC
  94.38   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
Turbidity Reduction
TDS Reduction
Pentair GRO-475M FDF1-RC
GRO75-RC
F1B1-RC
F1GC-RC
  21.08   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
Turbidity Reduction
TDS Reduction
Pentair GRO-575B FDF1-RC
GRO75-RC
F2B2-RC2
F1GC-RC
F2B1-RC
  21.08   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
Turbidity Reduction
TDS Reduction
Pentair GRO-575M FDF1-RC
GRO75-RC
F2B2-RC2
F1GC-RC
F2B1-RC
  21.08   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
Turbidity Reduction
TDS Reduction
Pentair RO-2550 TLC-50
P5
EPM-10
GS-10RO
  15.04   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[1] ROR2000 is a replacement kit containing RS14, CB1, and two o-rings.					
[2] ROR2050 is a replacement kit containing R200, CB1, RS14, and two o-rings.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

COMPONENTS: Membrane Elements[3]
Pentair TLC-100[4]    
Pentair TLC-24[4]    
Pentair TLC-36[4]    
Pentair TLC-50[4]    
Pentair TLC-50F[4]    
Pentair TLC-75[4]    
Pentair TLC-75I[4]    

   
[3] Conforms to material requirements only. Membranes require a 24 hour flushing and
    conditioning procedure.
[4] These elements have been tested for the reduction of Arsenic, Barium, Cadmium, Chromium
    (Hexavelent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead, Radium 226/228,
    and Selenium. The test data results may be transferred to other manufacturer's systems,
    if the systems meet the requirements.

COMPONENTS: Membrane Elements, Encapsulated[4] [5]
Pentair GRO-36EN    
Pentair GRO-50EN    
Pentair GRO-75EN    

   
[4] These elements have been tested for the reduction of Arsenic, Barium, Cadmium, Chromium
    (Hexavelent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead, Radium 226/228,
    and Selenium. The test data results may be transferred to other manufacturer's systems,
    if the systems meet the requirements.
[5] Conforms to material and structural integrity requirements only. Membranes require a 24
    hour flushing and conditioning procedure.

NOTE: These components do not bear the NSF Mark.  Evidence of Certification will appear on the
      manufacturer's literature and packaging.

Number of matching Manufacturers is 1
Number of matching Products is 23
Processing time was 0 seconds