NSF Product and Service Listings
These NSF Official Listings are current as of Saturday, December 21, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?Company=C0257345&
Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.
NSF/ANSI 42
Drinking Water Treatment Units - Aesthetic Effects
Drinking Water Treatment Units - Aesthetic Effects
LG Electronics Inc. | |
170,Seongsanpaechong-ro | |
Seongsan-gu, Changwon-si | |
Gyeongsangnam-do, 51533 | |
Korea, Republic of | |
82 55 268 4622 | |
Visit this company's website |
Facility : Gyeongsangnam-do, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
MDJ64844601 | LT1000P LT1000PC LT1000PCS ADQ747935 |
200(1) | 0.5 | Chlorine Reduction Taste and Odor Reduction Nominal Particulate Reduction, Class I |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Refrigerator Filter, Integrated [Pb] |
||||||
ADQ36006101-S | ADQ36006101 | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
ADQ36006102-S | ADQ36006102 | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
ADQ36006108-S | ADQ36006108 | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
ADQ36006109-S | ADQ36006109 | 200(1) | .5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
ADQ747937[2] | MDJ648444 MDJ648447 MDJ648445 LT1300P |
200 | .3 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
ADQ74793704 | MDJ64844405 MDJ648447 MDJ663312 |
105(1) | .3 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] Replacement element LT1300P represents a set packaging of MDJ648444, MDJ648447, and MDJ648445. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
COMPONENTS: Filter Cartridges[3] |
||||||
MDJ648444 | ||||||
MDJ64844405 | ||||||
MDJ64844406[4] | ||||||
MDJ648445 | ||||||
MDJ648447 | ||||||
MDJ66331002[4] | ||||||
MDJ663312 | ||||||
  [3] Conforms to the material and structural integrity requirements only. [4] Encapsulated filter MDJ66331002 is always used with MDJ64844406 as a set. |
NSF/ANSI 53
Drinking Water Treatment Units - Health Effects
Drinking Water Treatment Units - Health Effects
LG Electronics Inc. | |
170,Seongsanpaechong-ro | |
Seongsan-gu, Changwon-si | |
Gyeongsangnam-do, 51533 | |
Korea, Republic of | |
82 55 268 4622 | |
Visit this company's website |
Facility : Gyeongsangnam-do, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
MDJ64844601 | LT1000P LT1000PC LT1000PCS ADQ747935 |
200(1) | 0.5 | 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Refrigerator Filter, Integrated [Pb] |
||||||
ADQ36006101-S | ADQ36006101 | 200(1) | .5 | 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction P-Dichlorobenzene Reduction |
||
ADQ36006102-S | ADQ36006102 | 200(1) | .5 | 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction P-Dichlorobenzene Reduction |
||
ADQ36006108-S | ADQ36006108 | 200(1) | .5 | 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction P-Dichlorobenzene Reduction |
||
ADQ36006109-S | ADQ36006109 | 200(1) | .5 | 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction P-Dichlorobenzene Reduction |
||
ADQ747937[2] [3] | MDJ648444 MDJ648447 MDJ648445 LT1300P |
200 | .3 | 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Chromium (Trivalent) Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction PFOA Reduction PFOS Reduction Toxaphene Reduction Turbidity Reduction VOC Reduction ** Microcystin Reduction Chlordane Reduction MTBE Reduction PCB Reduction |
||
ADQ74793704 | MDJ64844405 MDJ648447 MDJ663312 |
105(1) | .3 | 2,4-D Reduction Asbestos Reduction Cyst Reduction Lead Reduction Mercury Reduction Cadmium Reduction Chlordane Reduction PCB Reduction Toxaphene Reduction Turbidity Reduction VOC Reduction ** |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] Replacement element LT1300P represents a set packaging of MDJ648444, MDJ648447, and MDJ648445. [3] PFOA/PFOS reduction claim evaluated to the 2021 version of NSF/ANSI Standard 53. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
NSF/ANSI 401
Drinking Water Treatment Units - Emerging Compounds/Incidental Contaminants
Drinking Water Treatment Units - Emerging Compounds/Incidental Contaminants
LG Electronics Inc. | |
170,Seongsanpaechong-ro | |
Seongsan-gu, Changwon-si | |
Gyeongsangnam-do, 51533 | |
Korea, Republic of | |
82 55 268 4622 | |
Visit this company's website |
Facility : Gyeongsangnam-do, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[Pb] |
||||||
MDJ64844601 | LT1000P LT1000PC LT1000PCS ADQ747935 |
200 | 0.5 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Metolachlor Reduction Microplastics Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
  [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Refrigerator Filter, Integrated [Pb] |
||||||
ADQ36006101-S | ADQ36006101 | 200 | .5 | Microplastics Reduction | ||
ADQ36006102-S | ADQ36006102 | 200 | .5 | Microplastics Reduction | ||
ADQ36006108-S | ADQ36006108 | 200 | .5 | Microplastics Reduction | ||
ADQ36006109-S | ADQ36006109 | 200 | .5 | Microplastics Reduction | ||
ADQ747937[1] | MDJ648444 MDJ648447 MDJ648445 LT1300P |
200 | .3 | Bisphenol A Reduction Estrone Reduction Ibuprofen Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction Meprobamate Reduction Atenolol Reduction Carbamazepine Reduction DEET Reduction Metolachlor Reduction Trimethoprim Reduction Linuron Reduction TCEP Reduction TCPP Reduction Microplastics Reduction |
||
ADQ74793704 | MDJ64844405 MDJ648447 MDJ663312 |
105 | .3 | Atenolol Reduction Bisphenol A Reduction Carbamazepine Reduction DEET Reduction Estrone Reduction Ibuprofen Reduction Linuron Reduction Meprobamate Reduction Metolachlor Reduction Microplastics Reduction Naproxen Reduction Nonylphenol Reduction Phenytoin Reduction TCEP Reduction TCPP Reduction Trimethoprim Reduction |
||
  [1] Replacement element LT1300P represents a set packaging of MDJ648444, MDJ648447, and MDJ648445. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Number of matching Manufacturers is 3
Number of matching Products is 28
Processing time was 0 seconds