NSF Product and Service Listings

These NSF Official Listings are current as of Wednesday, December 4, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?Standard=053&Company=C0548857&

Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.


NSF/ANSI 53
Drinking Water Treatment Units - Health Effects



 
Samsung Electronics Co., Ltd. 
129 Samsung-ro Yeongtong-gu
Suwon-si, Gyeonggi-Do 
16677 
Korea, Republic of 
82 31 8062 6129

Facility : Gwansan-gu, Gwangju, Korea, Republic of

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In to Separate Tap [Pb]
RWPa4 x 2bcde y[1] [2] HAF-HIM-1
HAF-HIM-2
330 .45   Asbestos Reduction
Chlordane Reduction
Chromium (Trivalent) Reduction
Cyst Reduction
Lead Reduction
MTBE Reduction
Mercury Reduction
Microcystin Reduction
PCB Reduction
PFOA Reduction
PFOS Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **

   
[1] RWPa4 x 2bcde y denotes the following:
    "a, d+e" refers to exterior design features
    "b" refers to energy grade
    "c" refers to year of production
    "x" refers to module combination (1, 2, 4)
    "y" refers to faucet type (M - single faucet, D - Docking faucet)
[2] PFOA/PFOS reduction claim evaluated to the 2021 version of NSF/ANSI Standard 53.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

Refrigerator Filter, Aftermarket [Pb]
RWP50020BWW[2] [3] HAF-HIM-1
HAF-HIM-2
330 .45   Asbestos Reduction
Chlordane Reduction
Chromium (Trivalent) Reduction
Cyst Reduction
Lead Reduction
MTBE Reduction
Mercury Reduction
Microcystin Reduction
PCB Reduction
PFOA Reduction
PFOS Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **

   
[2] PFOA/PFOS reduction claim evaluated to the 2021 version of NSF/ANSI Standard 53.
[3] This filter system is used for the following refrigerator models with installation
    kit:		
    "RF85*9*****
    RF60*9*****
    RR40*8******
    RZ34*8******
    RR40*7*****
    RZ34*7*****
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

Facility : Gyeonggi-Do, Korea, Republic of

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In to Separate Tap [Pb]
RWPaxy1bcde(z)[2] [3] [4] HAF-HIN 1
HAF-HIN 2
HAF-HIN 3
660(1) .47   Arsenic (Pentavalent)<=50 ppb Reduction*
Asbestos Reduction
Chlordane Reduction
Chromium Reduction
Cyst Reduction
Lead Reduction
MTBE Reduction
Mercury Reduction
Microcystin Reduction
PCB Reduction
PFOA Reduction
PFOS Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] Service Cycle in LPM is 2,500L and flow rate in LPM is 1.8 LPM.
[3] TN: RWPaxy1bcde(z)
    - "a, d+e" refers to exterior design feature
    - "b, c" refers to sales type
    - "x, y" refers to module combination (x - 0, 1, 2, 5; y - 0, 1, 2, 3, 4)
    - "z" refers to faucet type (no digit - no faucet, M - single faucet)
[4] PFOA/PFOS reduction claim evaluated to the 2021 version of NSF/ANSI Standard 53.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

Refrigerator Filter, Aftermarket [Pb]
RWP70010TWW[4] [5] [6] HAF-HIN 1
HAF-HIN 2
HAF-HIN 3
660(1) .3   Asbestos Reduction
Chromium (Trivalent) Reduction
Cyst Reduction
Lead Reduction
MTBE Reduction
Mercury Reduction
Microcystin Reduction
PCB Reduction
PFOA Reduction
PFOS Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
Chlordane Reduction
Arsenic (Pentavalent)<=50 ppb Reduction*

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[4] PFOA/PFOS reduction claim evaluated to the 2021 version of NSF/ANSI Standard 53.
[5] This filter system is used for the following refrigerator models with installation kit:
    RF10*998****
    RF10*996****
    RF85***X***(*) (X can refer to A-Z)
    RZ38*988****
    RZ28*987****
    RR40*998****
[6]  Capacity in Liter is 2,500L and flow rate is 1.3 LPM.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

Number of matching Manufacturers is 1
Number of matching Products is 4
Processing time was 0 seconds