NSF Product and Service Listings
These NSF Official Listings are current as of Sunday, March 2, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?Standard=058&Company=C0600944&
Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.
NSF/ANSI 58
Reverse Osmosis Drinking Water Treatment Systems
Reverse Osmosis Drinking Water Treatment Systems
Hydronix Water Technology | |
8630 Rochester Avenue | |
Rancho Cucamonga, CA 91730 | |
United States | |
909-527-6996 | |
Visit this company's website |
Facility : 1C
COMPONENTS: Membrane Pressure Vessels[2] |
||||||
MH03-1812WH | ||||||
  [2] Conforms to material and structural integrity requirements only. NOTE: These components do not bear the NSF Mark. Evidence of Certification will appear on the manufacturer's literature and packaging. |
||||||
Plumbed-In to Separate Tap |
||||||
Hydro Guard HDGT-45XX[3] | HDGT-SED5 HDGT-CB5 HDGT-TW50 C HDGT-CB5P |
20.1 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [3] XX= Faucet Finish AB - Antique Brass AW - Antique Wine BK - Black BN - Brushed Nickle CP - Chrome Plated IV - Ivory ORB - Oil Rubbed Bronze SN - Satin Nickle WH - White |
[1] Associated with a data transfer protocol. Test data results may be transferred to other manufacturer's systems if the systems meet requirements contained on the document entitled, "Data Transfer Procedure for Devices using Hydrondix Reverse Osmosis." This document is available from Hydronix Water Technology. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act.
Facility : 3C
Replacement | Daily Production | |||||
Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
Replacement Element: Plumbed-In to Separate Tap [Pb] |
||||||
HDGT-TW50 C[1] [2] [3] | N/A | 17 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
  * This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic. [1] Associated with a data transfer protocol. Test data results may be transferred to other manufacturer's systems if the systems meet requirements contained on the document entitled, "Data Transfer Procedure for Devices using Hydrondix Reverse Osmosis." This document is available from Hydronix Water Technology. [2] Hydro Guard HGDT-45CP [3] Certified for a max usage of 1 UNIT/14.4L (0.07 UNITS/L) [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Number of matching Manufacturers is 1
Number of matching Products is 3
Processing time was 0 seconds