NSF Product and Service Listings

These NSF Official Listings are current as of Monday, December 2, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?ProductFunction=053%7CArsenic+%28Pentavalent%29%3C%3D50+ppb+Reduction%2C+058%7CArsenic+%28Pentavalent%29%3C%3D50+ppb+Reduction&ProductType=Plumbed%2DIn+to+Separate+Tap&

Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.


NSF/ANSI 53
Drinking Water Treatment Units - Health Effects



 
Carbon Block Technology 
7251 Cathedral Rock Drive
Las Vegas, NV 89128 
United States 
702-360-8880
Visit this company's website

Facility : # 2 USA

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In to Separate Tap
CB-AS[2] CBTAS[1] 600 1   Arsenic (Pentavalent)<=50 ppb Reduction*
Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
MTBE Reduction
Mercury Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
PFOS Reduction
PFOA Reduction
Microcystin Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[1] Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] PFOA/PFOS reduction claim evaluated to the 2021 version of NSF/ANSI Standard 53.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                


 
Multipure / Multipure Drinking Water Systems 
Las Vegas Technology Center
7251 Cathedral Rock Drive 
Las Vegas, NV 89128 
United States 
800-622-9206 
702-360-8880
Visit this company's website

Facility : # 1 USA

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In to Separate Tap
AQUALUXE[4] [Pb] CBLX 500(1) .75   Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
MTBE Reduction
Mercury Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
Arsenic (Pentavalent)<=50 ppb Reduction*
Microcystin Reduction
PFOA Reduction
PFOS Reduction
Aquaperform[3] [4] [Pb] CB11As 600(1) 1   Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
MTBE Reduction
Mercury Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
Arsenic (Pentavalent)<=50 ppb Reduction*
Microcystin Reduction
PFOA Reduction
PFOS Reduction
CB-EXTRA[4] [Pb] CBXT 340(1) .71   Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
MTBE Reduction
Mercury Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
Arsenic (Pentavalent)<=50 ppb Reduction*
Microcystin Reduction
PFOA Reduction
PFOS Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] This system is also Certified under the following SKUS: AQBRITEBL, AQBRITEBLK,
    AQBRITEGR, AQBRITEPI, AQBRITEPR, AQBRITEWHT, AQBRITEEYE.
[3] Suffix I = Unit has no hardware;  appropriate for in line installation.
[4] PFOA/PFOS reduction claim evaluated to the 2021 version of NSF/ANSI Standard 53.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                


 
Samsung Electronics Co., Ltd. 
129 Samsung-ro Yeongtong-gu
Suwon-si, Gyeonggi-Do 
16677 
Korea, Republic of 
82 31 8062 6129

Facility : Gyeonggi-Do, Korea, Republic of

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In to Separate Tap [Pb]
RWPaxy1bcde(z)[2] [3] [4] HAF-HIN 1
HAF-HIN 2
HAF-HIN 3
660(1) .47   Arsenic (Pentavalent)<=50 ppb Reduction*
Asbestos Reduction
Chlordane Reduction
Chromium Reduction
Cyst Reduction
Lead Reduction
MTBE Reduction
Mercury Reduction
Microcystin Reduction
PCB Reduction
PFOA Reduction
PFOS Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] Service Cycle in LPM is 2,500L and flow rate in LPM is 1.8 LPM.
[3] TN: RWPaxy1bcde(z)
    - "a, d+e" refers to exterior design feature
    - "b, c" refers to sales type
    - "x, y" refers to module combination (x - 0, 1, 2, 5; y - 0, 1, 2, 3, 4)
    - "z" refers to faucet type (no digit - no faucet, M - single faucet)
[4] PFOA/PFOS reduction claim evaluated to the 2021 version of NSF/ANSI Standard 53.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                


 
Watpure International Ltd. 
207 Regent Street, 3rd Floor
London W1B 3HH 
United Kingdom 
44 20 3286 8588

Facility : # 1 USA

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In to Separate Tap
WTPAs[2] AsCB-WTP 600(1) 1   Arsenic (Pentavalent)<=50 ppb Reduction*
Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
PFOA Reduction
PFOS Reduction
Microcystin Reduction
ZAS[2] F-AsZ 600(1) 1   Asbestos Reduction
Chlordane Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
MTBE Reduction
PCB Reduction
Toxaphene Reduction
Turbidity Reduction
VOC Reduction **
Arsenic (Pentavalent)<=50 ppb Reduction*
Microcystin Reduction
PFOA Reduction
PFOS Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] PFOA/PFOS reduction claim evaluated to the 2021 version of NSF/ANSI Standard 53.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

NSF/ANSI 58
Reverse Osmosis Drinking Water Treatment Systems



Everpure LLC 
1040 Muirfield Drive
Hanover Park, IL 60133 
United States 
800-323-7873 
Visit this company's website

Facility : Hanover Park, IL

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap
Conserv 75E[Pb] 4CC
GRO-75EN
4FC5
4CB5
  50.51   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
Conserv 75S[Pb] 4CC
GRO-75EN
4FC5
  50.51   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
LVRO-75HE GRO-75EN
2FC5-S
2CB5
  14.66   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
LVRO-75HE+F GRO-75EN
2FC5-S
2CB5
  14.66   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[1] Certified for use with HE-II Upgrade Pump Kit Retro.
[2] System is Certified with optional 2nd RO Membrane Kit EV9970-00 or EV9969-00.
    
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


Facility : Roselle, IL

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap [Pb]
Conserv 75E 4CB5
4CC
4FC5
GRO-75EN
  50.51   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
Conserv 75S 4CC
4FC5
GRO-75EN
  50.51   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
LVRO-75HE 2CB5
2FC5-S
GRO-75EN
  14.66   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
LVRO-75HE+F 2CB5
2FC5-S
GRO-75EN
  14.66   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[1] Certified for use with HE-II Upgrade Pump Kit Retro.
[2] System is Certified with optional 2nd RO Membrane Kit EV9970-00 or EV9969-00.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
Pentair Residential Filtration, LLC 
13845 Bishops Drive
Suite 200 
Brookfield, WI 53005 
United States 
800-279-9404 
262-238-4400

Facility : Roselle, IL

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap
Everpure Residential ROM IV[Pb] ROM-G75
ROM-PFK
ROM-PRE
ROM-PST
  14.66   Arsenic (Pentavalent)<=50 ppb Reduction*
Turbidity Reduction
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


Facility : Jiangsu Province, China

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap [Pb]
OmniFilter RO2050[1] [2] CB1
OM1
R200 Series A
ROR2000
RS14
ROR2050
  15.04   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
Pentair GRO-350B FDF1-RC
GRO50-RC
F1GC-RC
  14.96   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
Turbidity Reduction
TDS Reduction
Nitrate/Nitrite Reduction
Pentair GRO-350BP FDF1-RC
GRO50-RC
F1GC-RC
  99.08   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
Turbidity Reduction
TDS Reduction
Pentair GRO-475B FDF1-RC
GRO75-RC
F1B1-RC
F1GC-RC
  21.08   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
Turbidity Reduction
TDS Reduction
Pentair GRO-475BP FDF1-RC
GRO75-RC
F1B1-RC
F1GC-RC
  94.38   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
Turbidity Reduction
TDS Reduction
Pentair GRO-475M FDF1-RC
GRO75-RC
F1B1-RC
F1GC-RC
  21.08   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
Turbidity Reduction
TDS Reduction
Pentair GRO-575B FDF1-RC
GRO75-RC
F2B2-RC2
F1GC-RC
F2B1-RC
  21.08   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
Turbidity Reduction
TDS Reduction
Pentair GRO-575M FDF1-RC
GRO75-RC
F2B2-RC2
F1GC-RC
F2B1-RC
  21.08   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
Turbidity Reduction
TDS Reduction
Pentair RO-2550 TLC-50
P5
EPM-10
GS-10RO
  15.04   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[1] ROR2000 is a replacement kit containing RS14, CB1, and two o-rings.					
[2] ROR2050 is a replacement kit containing R200, CB1, RS14, and two o-rings.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

NOTE: These components do not bear the NSF Mark.  Evidence of Certification will appear on the
      manufacturer's literature and packaging.

Number of matching Manufacturers is 6
Number of matching Products is 25
Processing time was 0 seconds