NSF Product and Service Listings

These NSF Official Listings are current as of Monday, May 13, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?ProductFunction=053%7CLead+Reduction&ProductType=Plumbed%2DIn&

Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.


NSF/ANSI 53
Drinking Water Treatment Units - Health Effects



 
3M Purification Inc. 
400 Research Parkway
Meriden, CT 06450 
United States 
800-222-7880 
651 737 1374
Visit this company's website

Facility : New Ulm, MN

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
3MDW201 3MDW211 6000(1) 2.5   Benzene Reduction
Cyst Reduction
Lead Reduction
P-Dichlorobenzene Reduction
3MDW301 3MDW311 1000(1) .75   1,2,3-Trichloropropane
Asbestos Reduction
Cyst Reduction
Lead Reduction
MTBE Reduction
Trihalomethanes (TTHM) Reduction
VOC Reduction **
3MFF100 3MFF101 6000(1) 2.5   Benzene Reduction
Cyst Reduction
Lead Reduction
P-Dichlorobenzene Reduction
3US-MAX-S01 3US-MAX-F01 1,500(1) 1.5   Cyst Reduction
Lead Reduction
Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
P-Dichlorobenzene Reduction
3US-MAX-S01H 3US-MAX-F01H 1,500(1) 1.5   Cyst Reduction
Lead Reduction
Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
P-Dichlorobenzene Reduction
AP-DWS1000 LF AP-DW80
AP-DW90
625(1) .6   Cyst Reduction
Lead Reduction
Turbidity Reduction
VOC Reduction **
Aramark Gold[5] Gold 1000(1) .75   Asbestos Reduction
Cyst Reduction
Lead Reduction
Aramark Platinum[5] Platinum 1000(1) .75   Asbestos Reduction
Cyst Reduction
Lead Reduction
ATIFF6000 ATIFF6001 6000(1) 2.5   Benzene Reduction
Cyst Reduction
Lead Reduction
P-Dichlorobenzene Reduction
Better Waters XL7000 XL7000CR 6000(1) 2.5   Benzene Reduction
Cyst Reduction
Lead Reduction
P-Dichlorobenzene Reduction
Body Glove BG-1000 BG-1000C 1000(1) .6   Asbestos Reduction
Cyst Reduction
Lead Reduction
Body Glove BG-3000 BG-3000C 450(1) .75   Asbestos Reduction
Cyst Reduction
Lead Reduction
VOC Reduction **
Body Glove BG-6000FF BG-6000FFC 6000(1) 2.5   Benzene Reduction
Cyst Reduction
Lead Reduction
P-Dichlorobenzene Reduction
Body Glove BG-12000 BG-12000C 1000(1) .75   1,2,3-Trichloropropane
Asbestos Reduction
Cyst Reduction
Lead Reduction
MTBE Reduction
Trihalomethanes (TTHM) Reduction
VOC Reduction **
DWS160-L 160-L 6000(1) 2.5   Benzene Reduction
Cyst Reduction
Lead Reduction
P-Dichlorobenzene Reduction
EQHP-5C EQHP-5CCRTG 4500(1) 1.5   Cyst Reduction
Lead Reduction
FF-6000 FF-6000R 6000(1) 2.5   Benzene Reduction
Cyst Reduction
Lead Reduction
P-Dichlorobenzene Reduction
FM 1500-B 47-5574707 1500(1) .6   Asbestos Reduction
Cyst Reduction
Lead Reduction
FM DWS 1500 FM 1500 1500(1) .6   Asbestos Reduction
Lead Reduction
Cyst Reduction
ReadyRefresh AccuPure FF1 AccuPure FF1-C 6000 2.5   Benzene Reduction
Cyst Reduction
Lead Reduction
P-Dichlorobenzene Reduction
VH3/OWS120-L OWS120-L 1200(1) .6   Asbestos Reduction
Cyst Reduction
Lead Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[5] Available with the VH3 series heads (as molded, with plug or with gauge).
[7] System uses 2 HF60-CL cartridges.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

Facility : Guangzhou, China

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
3US-S003-5 3US-F003-5 750(1) .75   Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
3US-S003-5 3DS-F003-5 750(1) .75   Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
AP Easy Complete C-Complete 750(1) .75   Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
AP Easy LC C-LC 750(1) .75   Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
DS03 3DS-F003-5 750(1) .75   Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
S003 DIY F003 DIY 750(1) .75   Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

Facility : Nuevo Leon, Mexico

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
3MDW101 3MDW111 500(1) .75   Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
4290510 4204490 750(1) .78   Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
AP EASY LC Cooler C-LC 750(1) .75   Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
AP Easy Complete C-Complete 750(1) .75   Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
AP Easy LC C-LC
3DS-F002-5
750(1) .75   Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
AP-DWS100 AP-DWS1100R 1000 .75   Asbestos Reduction
Cyst Reduction
Lead Reduction
AP-DWS1200 AP-DWS1200R 1000(1) .75   Asbestos Reduction
Cyst Reduction
Lead Reduction
MTBE Reduction
Trihalomethanes (TTHM) Reduction
VOC Reduction **
Body Glove BG-3000S BG-3000R 350(1) .75   Asbestos Reduction
Lead Reduction
MTBE Reduction
Trihalomethanes (TTHM) Reduction
VOC Reduction **
Cyst Reduction
Complete C-Complete 750(1) .75   Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
Complete Cooler C-Complete 750(1) .75   Asbestos Reduction
Atrazine Reduction
Carbofuran Reduction
Benzene Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
EP25/EP25 EP25 1150(1) .6   Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
2,4-D Reduction
FM-750 47-550101 750(1) .75   Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
LC C-LC 750(1) .75   Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
LC Cooler C-LC 750(1) .75   Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
VB-750 47-550102 750(1) .75   Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                


 
Aquazon Solutions Inc. 
9720 Coit Road
Suite 220 307 
Plano, TX 75025 
United States 
1 4697400561
Visit this company's website

Facility : Tianjin, China

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
PP-RWFS0100AH PP-RWF0100AH 300 .42   Cyst Reduction
Lead Reduction
Mercury Reduction
PP-RWFS0500AH PP-RWF0500AH 300 .5   Cyst Reduction
Lead Reduction
Mercury Reduction
PP-RWFS0600AH PP-RWF0600AH 300 .5   Cyst Reduction
Lead Reduction
Mercury Reduction
PP-RWFS0700AH PP-RWF0700AH 300 .5   Cyst Reduction
Lead Reduction
Mercury Reduction
PP-RWFS0900AH PP-RWF0900AH 300 .5   Cyst Reduction
Lead Reduction
Mercury Reduction
PP-RWFS1000AH PP-RWF1000AH 300 .5   Cyst Reduction
Lead Reduction
Mercury Reduction
PP-RWFS1100AH PP-RWF1100AH 300 .35   Cyst Reduction
Lead Reduction
Mercury Reduction
PP-RWFS1200AH PP-RWF1200AH 200 .5   Cyst Reduction
Lead Reduction
Mercury Reduction
PP-RWFS3300AH PP-RWF3300AH 300 .5   Cyst Reduction
Lead Reduction
Mercury Reduction
PP-RWFS3500AH PP-RWF3500AH 200 .41   Cyst Reduction
Lead Reduction
Mercury Reduction



 
Avalon 
585 Prospect Street
Suite #200 
Lakewood, NJ 08701 
United States 
212-658-0575

Facility : Foshan, China

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [Pb]
A4 SYSTEM A4FILTER 1500(1) .5   Cyst Reduction
Lead Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
Brio Water Technology, Inc. 
768 Turnbull Canyon Road
Hacienda Heights, CA 91745 
United States 
888-517-5667 
800-781-1680
Visit this company's website

Facility : Foshan, China

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [Pb]
FUS200R RPFUSCTO5MS2 1500(1) .5   Cyst Reduction
Lead Reduction
FUS300R RPFUSCTO5MS2 1500(1) .5   Cyst Reduction
Lead Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



EcoWater Systems LLC 
P.O. Box 64420
St. Paul, MN 55164 
United States 
800-869-2837 
Visit this company's website

Facility : Iuka, MS

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [Pb]
EAFF-100 [2] 2000(1) 1.8   Benzene Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
EcoWater Advanced Lead Filtration System Lead Filter 2000(1) 1.8   Benzene Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] Advanced Faucet Filter
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
Elkay Manufacturing Company 
1333 Butterfield Road
Suite 200 
Downers Grove, IL 60515 
United States 
630-574-8484

Facility : # 1 Mexico

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [Pb]
50000WD 51300C 3000(1) 1.5   Cyst Reduction
Lead Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



Everpure LLC 
1040 Muirfield Drive
Hanover Park, IL 60133 
United States 
800-323-7873 
Visit this company's website

Facility : Hanover Park, IL

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
1.5NZ-LS[Pb] 1.5NZ-LS 1800(1) 1.5   Cyst Reduction
Lead Reduction
1.5Z-LS[Pb] 1.5Z-LS 1800(1) 1.5   Cyst Reduction
Lead Reduction
1NZ-LS[Pb] 1NZ-LS 1100(1) 1   Cyst Reduction
Lead Reduction
1Z-LS[Pb] 1Z-LS 1100(1) 1   Cyst Reduction
Lead Reduction
2NZ-LS[Pb] 2NZ-LS 2500(1) 1.5   Cyst Reduction
Lead Reduction
2Z-LS[Pb] 2Z-LS 2500(1) 1.5   Cyst Reduction
Lead Reduction
QL2-OW200L[2] [3] [Pb] OW200L 480(1) .5   Cyst Reduction
Lead Reduction
Trihalomethanes (TTHM) Reduction
QL3-OW200L[Pb] OW200L 480(1) .5   Cyst Reduction
Lead Reduction
Trihalomethanes (TTHM) Reduction
QL3B-AquaMark 1[4] [Pb] AquaMark 1 1000(1) .5   Asbestos Reduction
Cyst Reduction
Lead Reduction
QL3B-AquaMark 2[4] [Pb] AquaMark 2 1000(1) .5   Cyst Reduction
Lead Reduction
QL3B-OW200L[Pb] OW200L 480(1) .5   Cyst Reduction
Lead Reduction
Trihalomethanes (TTHM) Reduction
Quantum 1000 Filter[2] [3] [Pb] Quantum 1000 750(1) .5   Cyst Reduction
Lead Reduction
Quantum 4000 Filter[Pb] Quantum 4000 2000(1) .5   Cyst Reduction
Lead Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] From date code 1C38
[3] From date code 1C48
[4] From date code 1G1622
[5] From date code 1G159.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
Filter Group Inc. 
243 Queen Street West
Toronto, ON M5V 1Z4 
Canada 
844-325-4792
Visit this company's website

Facility : # 1 USA

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In[Pb]
Home Water EZChange Drinking Water Filter FG-CBT-CIVOC
FG-CBT-LEAD
4,000 1   Lead Reduction

   
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
Foshan Midea Chungho Water Purification Equipment Co., Ltd. 
No. 68 Guangle Road, Beijiao, Shunde
Foshan, Guangdong 
528311 
China 
86 134 5058 6360
Visit this company's website

Facility : Foshan, China

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [Pb]
OS1 System OS1 Filter-F1 1500(1) .5   Cyst Reduction
Lead Reduction
OS2 System OS2 Filter-F1 1500(1) .5   Cyst Reduction
Lead Reduction
OS3 SYSTEM OS3 FILTER-F1 1500(1) .5   Cyst Reduction
Lead Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
General Ecology, Inc. 
151 Sheree Boulevard
Exton, PA 19341 
United States 
800-441-8166 
610-363-7900
Visit this company's website

Facility : Exton, PA

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [Pb]
Nature Pure Select QC2-PB PB-2QC 750(1) .75   Cyst Reduction
Lead Reduction
Nature Pure Select QC2-PB Basic PB-2QC 750(1) .75   Cyst Reduction
Lead Reduction
Seagull IV Select X1-PB PB-1SG 1,000(1) 1   Cyst Reduction
Lead Reduction
Seagull IV Select X1-PB Basic PB-1SG 1,000(1) 1   Cyst Reduction
Lead Reduction
Seagull IV Select X2-PB PB-2SG 2,000(1) 2   Cyst Reduction
Lead Reduction
Seagull IV Select X2-PB Basic PB-2SG 2,000(1) 2   Cyst Reduction
Lead Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
GHP Group Inc. 
6440 West Howard Street
Niles, IL 60714 
United States 
877-227-4768 
847-324-5900
Visit this company's website

Facility : ShenZhen, China

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
PQC2FS PQCSED
PQCCRBL
500(1) .5   Cyst Reduction
Lead Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.



 
Haws Corporation 
1455 Kleppe Lane
Sparks, NV 89431 
United States 
888-640-4297 
775-359-4712
Visit this company's website

Facility : # 1 USA

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
Model 6441 N/A 1500(1) .5   Cyst Reduction
Lead Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.



 
Homeland Water Filters 
5528 Land O Lakes Boulevard
Land O Lakes, FL 34639 
United States 
813-929-0909

Facility : # 1 USA

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
H1KPL1 N/A 1500(1) .5   Lead Reduction
Cyst Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.



Hydroviv, LLC 
2944 Middlebrook Pike
Knoxville, TN 37921 
United States 
800-676-9312 
Visit this company's website

Facility : # 1 Mexico

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [Pb]
HYDROVIV-US-SRS-13xZIP 13xZIP 600 1   Lead Reduction
HYDROVIV-US-SRS-14cZIP[2] 14cZIP 360 1   Lead Reduction
PFOA Reduction
PFOS Reduction
VOC Reduction **
HYDROVIV-US-SRS-18pZIP[2] 18pZIP 450 1   Lead Reduction
PFOA Reduction
PFOS Reduction
HYDROVIV-US-SRS-43pZIP[2] 43pZIP 450 1   Lead Reduction
PFOA Reduction
PFOS Reduction
HYDROVIV-US-SRS-46cZIP[2] 46cZIP 360 1   Lead Reduction
PFOA Reduction
PFOS Reduction
VOC Reduction **
HYDROVIV-US-SRS-48xZIP 48xZIP 600 1   Lead Reduction
HYDROVIV-US-SRS-71xZIP[2] 71xZIP 600 .72   Lead Reduction
PFOA Reduction
PFOS Reduction
HYDROVIV-US-SRS-74pZIP[2] 74pZIP 450 .72   Lead Reduction
PFOA Reduction
PFOS Reduction
HYDROVIV-US-SRS-75cZIP[2] 75cZIP 360 .72   Lead Reduction
PFOA Reduction
PFOS Reduction
VOC Reduction **

   
[2] PFOA/PFOS reduction claim evaluated to the 2021 version of NSF/ANSI Standard 53.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

[1] Complete replacement element trade names are:
    * HYDROVIV-REP-SRS-13xZIP
    * HYDROVIV-REP-SRS-48xZIP
    * HYDROVIV-REP-SRS-71xZIP
    * HYDROVIV-REP-SRS-14cZIP
    * HYDROVIV-REP-SRS-46cZIP
    * HYDROVIV-REP-SRS-75cZIP
    * HYDROVIV-REP-SRS-18pZIP
    * HYDROVIV-REP-SRS-43pZIP
    * HYDROVIV-REP-SRS-74pZIP

** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

Facility : Knoxville, TN

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [Pb]
HYDROVIV-US-SRS-13xZIP 13xZIP[1] 600 1   Lead Reduction
HYDROVIV-US-SRS-14cZIP[2] 14cZIP[1] 360 1   Lead Reduction
PFOA Reduction
PFOS Reduction
VOC Reduction **
HYDROVIV-US-SRS-18pZIP[2] 18pZIP[1] 450 1   Lead Reduction
PFOA Reduction
PFOS Reduction
HYDROVIV-US-SRS-43pZIP[2] 43pZIP[1] 450 1   Lead Reduction
PFOA Reduction
PFOS Reduction
HYDROVIV-US-SRS-46cZIP[2] 46cZIP[1] 360 1   Lead Reduction
PFOA Reduction
PFOS Reduction
VOC Reduction **
HYDROVIV-US-SRS-48xZIP 48xZIP[1] 600 1   Lead Reduction
HYDROVIV-US-SRS-71xZIP[2] 71xZIP[1] 600 .72   Lead Reduction
PFOA Reduction
PFOS Reduction
HYDROVIV-US-SRS-74pZIP[2] 74pZIP[1] 450 .72   Lead Reduction
PFOA Reduction
PFOS Reduction
HYDROVIV-US-SRS-75cZIP[2] 75cZIP[1] 360 .72   Lead Reduction
PFOA Reduction
PFOS Reduction
VOC Reduction **

   
[1] Complete replacement element trade names are:
    * HYDROVIV-REP-SRS-13xZIP
    * HYDROVIV-REP-SRS-48xZIP
    * HYDROVIV-REP-SRS-71xZIP
    * HYDROVIV-REP-SRS-14cZIP
    * HYDROVIV-REP-SRS-46cZIP
    * HYDROVIV-REP-SRS-75cZIP
    * HYDROVIV-REP-SRS-18pZIP
    * HYDROVIV-REP-SRS-43pZIP
    * HYDROVIV-REP-SRS-74pZIP
[2] PFOA/PFOS reduction claim evaluated to the 2021 version of NSF/ANSI Standard 53.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                


 
Hydrovos 
P.O. Box 4761
Mission Viejo, CA 92690 
United States 
888-424-9185 
714-228-6000
Visit this company's website

Facility : Pingtung, Taiwan

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [Pb]
HV-DWSS-FF HV-DWSS-FFR 1500(1) 1.5   Cyst Reduction
Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Lead Reduction
P-Dichlorobenzene Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
Insinkerator LLC 
1250 International Drive
Mount Pleasant, WI 53177 
United States 
262-554-5432

Facility : Sturtevant, WI

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
F-1000S F-2000 500(1) .75   2,4-D Reduction
Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
F-2000S F-2000 500(1) .75   2,4-D Reduction
Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
HWT300-F2000S[Pb] F-2000 500 .75   2,4-D Reduction
Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
Kemflo / Filbur 
No. 3 Huan East Street, Da-Zhou
Pingtung 900 
Taiwan 
886 8 7524736

Facility : # 2 Pingtung, Taiwan

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [Pb]
KF-DWS-G KF-DWS-G-R 1500(1) 1.5   Asbestos Reduction
Lead Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
P-Dichlorobenzene Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
Liebherr Hausgeräte GmbH 
Memminger Straße 77-79
88416 Ochsenhausen 
Germany 
43 50809 21884
Visit this company's website

Facility : Tianjin, China

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In[1] [Pb]
RFS3902 7440011 300 .47   Cyst Reduction
Lead Reduction

   
[1] Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
MCM Co., Ltd. 
486, Jingwang-ro, Iwol-myeon
Jincheon-gun, Chungcheongbukdo 365-842 
Korea, Republic of 
82 43 531 7021

Facility : Chungcheongbukdo, Republic of Korea

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
ADQ73613401-S[Pb] ADQ73613401 200(1) .5   2,4-D Reduction
Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
ADQ73613402-S[Pb] ADQ73613402 200(1) .5   2,4-D Reduction
Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
LG/ADQ73613402[Pb] ADQ73613403 200(1) .5   2,4-D Reduction
Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
LG/MFKLG34212F01 ADQ73613403 200(1) .5   2,4-D Reduction
Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
Microfilter Co., Ltd. 
15-1, Gwinong 3-gil, Deoksan-eup
(162-1 Sansuri, Deoksan-eup) 
Jincheon-gun, Chungcheongbuk-do 
27856,  
Korea, Republic of 
82 43 536 5221
Visit this company's website

Facility : # 1 Chungcheongbuk-do, Republic of Korea

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
S2HB-1NNN-SS-CB S2FR-CB01-SS-00 300 .5   Asbestos Reduction
Benzene Reduction
Atrazine Reduction
2,4-D Reduction
Cyst Reduction
Endrin Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Tetrachloroethylene Reduction
Turbidity Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


Facility : Chungcheongbuk-Do, Korea, Republic of

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
S2HB-1NNN-SS-CB S2FR-CB01-SS-00 300(1) .5   2,4-D Reduction
Asbestos Reduction
Atrazine Reduction
Benzene Reduction
Cyst Reduction
Endrin Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Tetrachloroethylene Reduction
Turbidity Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



Mountain Plumbing Products 
2611 Regent Boulevard
Suite 100 
DFW Airport, TX 75261 
United States 
888-222-9140 
Visit this company's website

Facility : # 1 USA

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
MT1250XL N/A 1250(1) .5   Lead Reduction
Cyst Reduction
MT3K-HF MT3K-HC/RFC 3000(1) 1.67   Lead Reduction
Cyst Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.



 
NeoLogic Distribution 
9450 Southwest Gemini Drive
ECM #83358 
Beaverton, OR 97008 
United States 
855-896-3525

Facility : Caldwell, ID

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
NP-OVF001[2] N/A 1250(1) .5   Cyst Reduction
Lead Reduction
NP-QCB01PB[2] N/A 1250(1) .5   Cyst Reduction
Lead Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] May include a 2-letter suffix with any combination of the following: A, B, C, J, K, and
    S.



 
Omnipure Filter Co. 
1904 Industrial Way
Caldwell, ID 83605 
United States 
208-454-2597
Visit this company's website

Facility : Caldwell, ID

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
ELF 1M Lead ELF 1ML 3000 1.67   Cyst Reduction
Lead Reduction
ELF 1M Lead EXT ELF 1ML 3000(1) 1.67   Cyst Reduction
Lead Reduction
ELF 1M-P EXT ELF 1ML 3000(1) 1.67   Cyst Reduction
Lead Reduction
ELF 1M-P Lead ELF 1ML-P 3000 1.67   Cyst Reduction
Lead Reduction
ELF5615 N/A 1500(1) .5   Cyst Reduction
Lead Reduction
K5515[2] N/A 1250(1) .5   Cyst Reduction
Lead Reduction
K5615[2] N/A 1500(1) .5   Cyst Reduction
Lead Reduction
L5515[3] N/A 1250 .5   Lead Reduction
Cyst Reduction
L5615[3] N/A 1500 .5   Lead Reduction
Cyst Reduction
Q5515[2] N/A 1250(1) .5   Lead Reduction
Cyst Reduction
Q5515 N/A 1500 .5   Cyst Reduction
Lead Reduction
Q5515 PF[2] N/A 250 .5   Cyst Reduction
Lead Reduction
PFOA Reduction
PFOS Reduction
Q5615[2] N/A 1500(1) .5   Lead Reduction
Cyst Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] May include a 2-letter suffix with any combination of the following: A, B, C, J, and S.
[3] Models are Certified for use with the AA, BB, CC, and JJ heads.



 
Pentair Residential Filtration, LLC 
13845 Bishops Drive
Suite 200 
Brookfield, WI 53005 
United States 
800-279-9404 
262-238-4400

Facility : Hanover Park, IL

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [Pb]
Everpure Residential 3500[2] [3] 3500 300(1) .5   Cyst Reduction
Lead Reduction
VOC Reduction **
Everpure Residential BW-400 Filter[2] [3] BW-400 1000(1) .5   Cyst Reduction
Lead Reduction
Everpure Residential BW-500 Filter[2] [3] BW-500 480(1) .5   Cyst Reduction
Lead Reduction
Trihalomethanes (TTHM) Reduction
Everpure Residential EF-1500 EF-1500 1500(1) 2.2   Cyst Reduction
Lead Reduction
Everpure Residential EF-3000 EF-3000 3000(1) 2.2   Cyst Reduction
Lead Reduction
Everpure Residential EF-6000 EF-6000 6000(1) 1.67   Cyst Reduction
Lead Reduction
Everpure Residential H-104 Filter[2] [3] H-104 1000(1) .5   Cyst Reduction
Lead Reduction
Everpure Residential H-300 Filter[2] [3] H-300 300(1) .5   Cyst Reduction
Lead Reduction
VOC Reduction **
Everpure Residential H-300-HSD[2] [3] H-300-HSD 300(1) 0.5   Cyst Reduction
Lead Reduction
Everpure Residential H-300-NXT H-300-NXT 300(1) .5   Cyst Reduction
Lead Reduction
Everpure Residential H-54 Filter[2] [3] H-54 750(1) .5   Cyst Reduction
Lead Reduction
Everpure Residential PBS-400 PBS-400 3000(1) 2.2   Cyst Reduction
Lead Reduction
Everpure Residential S-104 Filter[2] [3] S-104 1000(1) .5   Cyst Reduction
Lead Reduction
Everpure Residential S-54 Filter[2] [3] S-54 750(1) .5   Cyst Reduction
Lead Reduction
Everpure Residential SPA-400[Pb] SPA-400 3000(1) 2.2   Cyst Reduction
Lead Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] From date code 1C38
[3] From date code 1C48
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

Facility : Reynosa, Mexico

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
Easy Flow[Pb] RC-LCT 3000(1) 1.4   Cyst Reduction
Lead Reduction
OmniFilter PB35[Pb] PB35-10 20000(1) 5   Cyst Reduction
Lead Reduction
OmniFilter PB55[Pb] PB55-20 40000(1) 10   Cyst Reduction
Lead Reduction
Pentair LR-1500[Pb] LR-FB10 1500(1) 2.5   Lead Reduction
Pentair LR-BB25[Pb] LR-FB10BB 20000(1) 5   Cyst Reduction
Lead Reduction
Pentair LR-BB50[Pb] LR-FB20BB 40000(1) 10   Cyst Reduction
Lead Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                


 
Sears Brands Management Corp 
3333 Beverly Road
Hoffman Estates, IL 60179 
United States 
847-286-9279
Visit this company's website

Facility : # 1 Republic of Korea

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
ADQ73613402-S[Pb] ADQ73613402
469490
200(1) .5   Benzene Reduction
Atrazine Reduction
2,4-D Reduction
Carbofuran Reduction
Cyst Reduction
Lead Reduction
Lindane Reduction
Mercury Reduction
P-Dichlorobenzene Reduction
Toxaphene Reduction
Asbestos Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
Senwater Systems LLC 
1300 East Ninth Street
Cleveland, OH 44114 
United States 
216-262-0802
Visit this company's website

Facility : # 2 USA

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
QCM318-L QCM318-L (1) 1.67   Cyst Reduction
Lead Reduction
QCS116 N/A 1,250 .5   Lead Reduction
Cyst Reduction
QCS118 N/A 1,500 .5   Lead Reduction
Cyst Reduction
QCS120 N/A 1,250 .5   Lead Reduction
Cyst Reduction
QCS122 N/A 1,500 .5   Lead Reduction
Cyst Reduction
QCS308-L QCS308-L (1) 1.67   Cyst Reduction
Lead Reduction
QCS318-L QCS318-L (1) 1.67   Cyst Reduction
Lead Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.



 
Southbend, a Middleby Corporation 
1100 Old Honeycutt Road
Fuquay Varina, NC 27526 
United States 
919-762-1008
Visit this company's website

Facility : Caldwell, ID

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
TruH2O M-CPLead TruH2O M-CP10L 3,000 1.67   Cyst Reduction
Lead Reduction
TruH2O QM-CL N/A 1,500 0.5   Cyst Reduction
Lead Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.



 
Systems IV 
6641 West Frye Road
Chandler, AZ 85226 
United States 
800-852-4221 
480-961-1255
Visit this company's website

Facility : # 1 USA

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
FF-C10 Lead FF-C10L 3000 1.67   Cyst Reduction
Lead Reduction
FF-CP10 Lead FF-CP10L 3000 1.67   Cyst Reduction
Lead Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.



 
Tozone National Inc. 
9720 Coit Road
Suite 220, #307 
Plano, TX 75025 
United States 
1 469 740 0568
Visit this company's website

Facility : Tianjin, China

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
RWFS0100AH RWF0100AH 300 .42   Cyst Reduction
Lead Reduction
Mercury Reduction
RWFS0500AH RWF0500AH 300 .5   Cyst Reduction
Lead Reduction
Mercury Reduction
RWFS0600AH RWF0600AH 300 .5   Cyst Reduction
Lead Reduction
Mercury Reduction
RWFS0700AH RWF0700AH 300 .5   Cyst Reduction
Lead Reduction
Mercury Reduction
RWFS0900AH RWF0900AH 300 .5   Cyst Reduction
Lead Reduction
Mercury Reduction
RWFS1000AH RWF1000AH 300 .5   Cyst Reduction
Lead Reduction
Mercury Reduction
RWFS1100AH RWF1100AH 300 .35   Cyst Reduction
Lead Reduction
Mercury Reduction
RWFS1200AH RWF1200AH 200 .5   Cyst Reduction
Lead Reduction
Mercury Reduction
RWFS3300AH RWF3300AH 300 .5   Cyst Reduction
Lead Reduction
Mercury Reduction
RWFS3500AH RWF3500AH 200 .41   Cyst Reduction
Lead Reduction
Mercury Reduction



 
Water Channel Partners 
1890 Woodlane Drive
Woodbury, MN 55125 
United States 
800-869-2837

Facility : # 3 USA

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [Pb]
Brita Total360 BRDPFS BRDPFF 2000(1) 1.8   Benzene Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
Ecodyne HCGRES HCGREF 750(1) .85   Cyst Reduction
Lead Reduction
Atrazine Reduction
Lindane Reduction
Turbidity Reduction
Ecodyne HDGRES HDGREF 750(1) .85   Cyst Reduction
Lead Reduction
Atrazine Reduction
Lindane Reduction
Turbidity Reduction
Ecopure EPINL40 N/A 2000(1) .5   Cyst Reduction
Lead Reduction
Ecopure EPWPFF EPWPRF 2000(1) 1.8   Benzene Reduction
Cyst Reduction
Lead Reduction
Mercury Reduction
Ecopure EPWRSS EPWRSF 750(1) .5   Cyst Reduction
Lead Reduction
Atrazine Reduction
Lindane Reduction
Turbidity Reduction
Whirlpool WHARSS5 WHARSF5 750(1) .5   Cyst Reduction
Lead Reduction
Atrazine Reduction
Lindane Reduction
Turbidity Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
Western Water International Inc. 
7715 Penn Belt Drive
Forestville, MD 20747 
United States 
301-568-0200
Visit this company's website

Facility : # 1 USA

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In
Aquaspace Water Systems AWS-R-2414 N/A 1500 .5   Cyst Reduction
Lead Reduction


Number of matching Manufacturers is 31
Number of matching Products is 182
Processing time was 0 seconds