Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?ProductFunction=053%7CLead+Reduction&ProductType=Refrigerator+Filter&
Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.
Drinking Water Treatment Units - Health Effects
A.O. Smith Corporation | |
11270 West Park Place | |
Milwaukee, WI 53224 | |
United States | |
800-527-1953 |
Facility : Haltom City, TX
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
AO-FF | AO-US-100-R | 200 | .5(1) | Asbestos Reduction Cyst Reduction Lead Reduction MTBE Reduction Mercury Reduction Turbidity Reduction VOC Reduction ** PFOA Reduction PFOS Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
AGA IMPORTS LLC | |
70 Canary Drive | |
Lakewood, NJ 08701 | |
United States | |
917-533-0138 |
Facility : # 3 China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] |
||||||
CWMF005-S | CWMF005 | 300 | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
GVF033-S | GVF033 | 200 | .3 | Cyst Reduction Lead Reduction Mercury Reduction |
||
GVF035-S | GVF035 | 300 | .47 | Cyst Reduction Lead Reduction Mercury Reduction |
||
GVF041-S | GVF041 | 200 | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
GVF042-S | GVF042 | 200 | .41 | Cyst Reduction Lead Reduction Mercury Reduction |
||
  [1] Claims of capacity or rated service cycle are not applicable for mechanical filtration. |
Altwell Tech Inc. | |
42-24, Daehwa-ro 150 beon-gil | |
Daedeok-gu, Daejeon | |
Korea, Republic of | |
888-637-3338 | |
213-637-5800 |
Facility : Daejeon, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
DA97-08006A-E[Pb] | DA29-00020B | 300(1) | .5 | 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Chlorobenzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction 1,2,4-Trichlorobenzene Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Electrolux Home Products | |
10200 David Taylor Drive | |
Charlotte, NC 28262 | |
United States | |
877-435-3287 | |
980-236-2000 | |
Visit this company's website |
Facility : West Haven, CT
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Prochill NGPT[2] | RWFVRF1 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Cyst Reduction VOC Reduction ** Atrazine Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
Pure Advantage NGFC-2000 | FC-100 FC-300 |
400(1) | .5 | 2,4-D Reduction Asbestos Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
PureAdvantage NGFC-2000 | EWF2CBPA | 400(1) | .5 | 2,4-D Reduction Asbestos Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Lindane Reduction |
||
PureAdvantage NGFC-2000 | EWF01 | 400(1) | .5 | 2,4-D Reduction Asbestos Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Lindane Reduction |
||
PureAdvantage PWF-1[5] | EPPWFU01 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction |
||
PureAdvantage PWF-1-U[6] | EPPWFU01 | 200(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Atrazine Reduction |
||
PureAdvantage Ultra[3] | EWF02 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Cyst Reduction VOC Reduction ** Atrazine Reduction |
||
PureAdvantage Ultra-U[4] | EWF02 | 200(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Cyst Reduction Atrazine Reduction |
||
PureSource 2 NGFC-2000 | FC-100 | 400(1) | .5 | 2,4-D Reduction Asbestos Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
PureSource 2 NGFC-2000 | WF2CB | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction Asbestos Reduction |
||
PureSource 3 | WF3CB | 200(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction |
||
PureSource Ultra | ULTRAWF | 200(1) | .65 | 1,2,4-Trichlorobenzene Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction MTBE Reduction VOC Reduction ** |
||
PureSource Ultra II[7] | EPTWFU01 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Cyst Reduction VOC Reduction ** Atrazine Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
PureSource Ultra II-U[8] | EPTWFU01 | 200(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Cyst Reduction Atrazine Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
pure advantage ™ NGFC-2000 | WF2CB | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction Asbestos Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] ProChill NGPT with Performance Indicator Device. [3] PureAdvantage Ultra with Performance Indicator Device. [4] PureAdvantage Ultra-U without Performance Indicator Device. [5] PureAdvantage PWF-1 with Performance Indicator Device. [6] PureAdvantage PWF-1-U without Performance Indicator Device. [7] PureSource Ultra II with Performance Indicator Device. [8] PureSource Ultra II-U without Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Facility : Singapore, Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Prochill NGPT[2] | RWFVRF1 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Cyst Reduction VOC Reduction ** Atrazine Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
PureAdvantage NGFC-2000 | EWF2CBPA | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Asbestos Reduction |
||
PureAdvantage NGFC-2000 | EWF01 | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Asbestos Reduction |
||
PureAdvantage PWF-1[5] | EPPWFU01 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction |
||
PureAdvantage PWF-1-U[6] | EPPWFU01 | 200(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction |
||
PureAdvantage Ultra[3] | EWF02 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Cyst Reduction VOC Reduction ** Atrazine Reduction |
||
PureAdvantage Ultra-U[4] | EWF02 | 200(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Cyst Reduction Atrazine Reduction |
||
PureSource 2 NGFC-2000 | FC-100 | 400(1) | .5 | 2,4-D Reduction Asbestos Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
PureSource 2 NGFC-2000 | WF2CB | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Asbestos Reduction |
||
PureSource 3 | WF3CB | 200 | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction |
||
PureSource Ultra | ULTRAWF | 200(1) | .65 | 1,2,4-Trichlorobenzene Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction MTBE Reduction VOC Reduction ** |
||
PureSource Ultra II[7] | EPTWFU01 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Cyst Reduction VOC Reduction ** Atrazine Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
PureSource Ultra II-U[8] | EPTWFU01 | 200(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Cyst Reduction Atrazine Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
pure advantage ™ NGFC-2000 | WF2CB | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Asbestos Reduction |
||
pure advantage™ NGFC-2000 | FC-100 FC-300 |
400(1) | .5 | 2,4-D Reduction Asbestos Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] ProChill NGPT with Performance Indicator Device. [3] PureAdvantage Ultra with Performance Indicator Device. [4] PureAdvantage Ultra-U without Performance Indicator Device. [5] PureAdvantage PWF-1 with Performance Indicator Device. [6] PureAdvantage PWF-1-U without Performance Indicator Device. [7] PureSource Ultra II with Performance Indicator Device. [8] PureSource Ultra II-U without Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Foshan Micro Midea Filter Mfg. Co., Ltd. | |
B Area Cherry Blossom Park | |
No. 19 Lingang Road, Bejiao Town Shunde | |
Foshan, Guangdong 528311 | |
China | |
86 135 9090 8470 |
Facility : Foshan, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
M-SJWF200 | SJWF200 | 200(1) | .5 | Cyst Reduction Lead Reduction |
||
MF-2008-R2 | MF-2008-R2R NS-WF26SS0-1 MIWF6200 MIWFT2100 |
200(1) | .5 | Cyst Reduction Lead Reduction |
||
MF-2008-TG | WF200 | 200(1) | .5 | Cyst Reduction Lead Reduction |
||
MF-2812-R4[Pb] | MF-2812-R4R MIWF8200 |
200(1) | .5 | Cyst Reduction Lead Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Frigidaire Home Products | |
10200 David Taylor Drive | |
Charlotte, NC 28262 | |
United States | |
1-800-559-7569 | |
980-236-2000 |
Facility : West Haven, CT
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Frigidaire PureSource 3 | WF3CB | 200(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction |
||
Frigidaire PureSource Ultra | ULTRAWF | 200(1) | .65 | 1,2,4-Trichlorobenzene Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction MTBE Reduction |
||
PureAdvantage NGFC-2000 | EWF01 | 400(1) | .5 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction Turbidity Reduction |
||
PurePour PWF-1 | EPPWFU01 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction Trichloroethylene Reduction |
||
PurePour WF-1[2] | FPPWFU01 | 125 | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction |
||
PurePour WF-1-U[3] | FPPWFU01 | 200 | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction |
||
PureSource 2 NGFC-2000 | WF2CB | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction Asbestos Reduction Benzene Reduction Carbofuran Reduction Endrin Reduction Ethylbenzene Reduction P-Dichlorobenzene Reduction |
||
PureSource Ultra II | EPTWFU01 | 125(1) | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] PurePourWF-1 with Performance Indicator Device. [3] PurePour WF-1-U without Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Facility : Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Frigidaire PureSource 3 | WF3CB | 200(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction |
||
Frigidaire PureSource Ultra | ULTRAWF | 200(1) | .65 | 1,2,4-Trichlorobenzene Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction MTBE Reduction VOC Reduction ** |
||
PureAdvantage NGFC-2000 | EWF01 | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Asbestos Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction |
||
PurePour PWF-1 | EPPWFU01 | 125(1) | .65 | 2,4-D Reduction Atrazine Reduction Asbestos Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction VOC Reduction ** Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Trichloroethylene Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
PurePour PWF-1[2] | FPPWFU01 | 125 | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction Tetrachloroethylene Reduction P-Dichlorobenzene Reduction |
||
PurePour WF-1-U[3] | FPPWFU01 | 200 | .65 | Asbestos Reduction Mercury Reduction Lead Reduction VOC Reduction ** Benzene Reduction Carbofuran Reduction 2,4-D Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Trichloroethylene Reduction Toxaphene Reduction Atrazine Reduction Cyst Reduction |
||
PureSource 2 NGFC-2000 | WF2CB | 400(1) | 0.5 | 2,4-D Reduction Alachlor Reduction Atrazine Reduction Asbestos Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction |
||
PureSource Ultra II | EPTWFU01 | 125(1) | .65 | 2,4-D Reduction Atrazine Reduction Asbestos Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Toxaphene Reduction VOC Reduction ** Tetrachloroethylene Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] PurePour WF-1 with Performance Indicator Device. [3] PurePour WF-1-U without Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
JFL Distributors Inc. / Pure Green Water Filters | |
1251 42nd Street Brooklyn | |
New York, NY 11219 | |
United States | |
800-659-6658 | |
347-534-4955 | |
Visit this company's website |
Facility : Guangdong, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
PG-4396508A | PG-4396508A | 300 | .31 | Lead Reduction | ||
PG-700PA | PG-700PA | 200 | .31 | Lead Reduction | ||
PG-8001A | PG-8001A | 300 | .31 | Lead Reduction | ||
PG-DA20A | PG-DA20A | 300 | .31 | Lead Reduction | ||
PG-MWFA | PG-MWFA | 300 | .31 | Lead Reduction |
LG Electronics Inc. | |
170,Seongsanpaechong-ro | |
Seongsan-gu, Changwon-si | |
Gyeongsangnam-do, 642-711 | |
Korea, Republic of | |
82 55 268 4622 | |
Visit this company's website |
Facility : Gyeongsangnam-do, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
MDJ64844601 | LT1000P LT1000PC LT1000PCS |
200(1) | 0.5 | 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Microfilter Co., Ltd. | ![]() |
15-1, Gwinong 3-gil, Deoksan-eup | |
(162-1 Sansuri, Deoksan-eup) | |
Jincheon-gun, Chungcheongbuk-do | |
27856, | |
Korea, Republic of | |
82 43 536 5221 | |
Visit this company's website |
Facility : # 1 Chungcheongbuk-do, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
8001036935 | 8001045102 | 250(1) | .55 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Lead Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction Ethylbenzene Reduction |
||
DA97-08006A-1[Pb] | DA29-00020B-1 DA29-00020B |
300 | .5 | Asbestos Reduction Benzene Reduction Atrazine Reduction 2,4-D Reduction Carbofuran Reduction Chlorobenzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction |
||
DA97-08006A-2[Pb] | DA29-00020B-1 DA29-00020B |
300 | .5 | 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Chlorobenzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Chungcheongbuk-Do, Korea, Republic of
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
8001036935 | 8001045102 | 250(1) | .55 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Ethylbenzene Reduction Lead Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction |
||
DA97-08006A-1[Pb] | DA29-00020B DA29-00020B-1 |
300(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Ethylbenzene Reduction Lead Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction 2,4-D Reduction Chlorobenzene Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
DA97-08006A-2[Pb] | DA29-00020B DA29-00020B-1 |
300(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Ethylbenzene Reduction Lead Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction 2,4-D Reduction Chlorobenzene Reduction Endrin Reduction Lindane Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Paragon Water Systems, Inc. | |
13805 Monroes Business Park | |
Tampa, FL 33635 | |
United States | |
727-538-4704 | |
Visit this company's website |
Facility : Tampa, FL
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
GV MWFGV | MWFGV | 300(1) | .5 | Lead Reduction | ||
HDX FMG-1 | FMG-1 | 300(1) | .5 | Lead Reduction | ||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Sears Brands Management Corp | |
3333 Beverly Road | |
Hoffman Estates, IL 60179 | |
United States | |
847-286-2500 | |
Visit this company's website |
Facility : Gyeongsangnam-do, Republic of Korea
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
ADQ74793502 | ADQ74793502 | 200[1] | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Lindane Reduction P-Dichlorobenzene Reduction 2,4-D Reduction Lead Reduction Mercury Reduction Cyst Reduction |
||
  [1] Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Sears Brands Management Corporation | |
3333 Beverly Road | |
Hoffman Estates, IL 60179 | |
United States | |
847-286-2500 | |
Visit this company's website |
Facility : Pingtung, Taiwan
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
P1KB1 | 9083 | 200(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction MTBE Reduction Mercury Reduction Trihalomethanes (TTHM) Reduction VOC Reduction ** |
||
P1KB2 | 9083 | 100(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Lead Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction Endrin Reduction Ethylbenzene Reduction Lindane Reduction MTBE Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Trihalomethanes (TTHM) Reduction VOC Reduction ** |
||
P8KB2L | 9081 | 200(1) | .50 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Turbidity Reduction |
||
P9KB2L | 9082 | 200(1) | .60 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Turbidity Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Sears Canada Inc. | |
290 Yonge Street | |
Toronto, ON M5B 2C3 | |
Canada | |
800-469-4663 |
Facility : Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Kenmore Ultra | 9919 | 200(1) | .65 | 1,2,4-Trichlorobenzene Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Sears Roebuck and Co. | |
3333 Beverly Road | |
Hoffman Estates, IL 60179 | |
United States | |
847-286-2198 |
Facility : Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
Kenmore NGFC 2000 | FC-100 | 400 | .5 | 2,4-D Reduction Asbestos Reduction Alachlor Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction |
||
Kenmoreclear! | 9999 | 200(1) | .65 | 1,2,4-Trichlorobenzene Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** MTBE Reduction |
||
Kenmorepure! | 9911 | 400(1) | .5 | Alachlor Reduction Atrazine Reduction Cyst Reduction Lead Reduction Lindane Reduction Mercury Reduction Toxaphene Reduction Turbidity Reduction 2,4-D Reduction |
||
Kenmore Ultra | 9999 | 200(1) | .65 | 1,2,4-Trichlorobenzene Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction Monochlorobenzene Reduction O-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** MTBE Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Sem Trading Company, Inc. | |
1942 Broadway Street | |
Suite 314C | |
Boulder, CO 80302 | |
United States | |
86 136 1301 4489 |
Facility : # 1 China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
DK-00003G | DK-00003G | 300 | .5 | Lead Reduction | ||
DK-00020B | DK-00020B | 300 | .5 | Lead Reduction | ||
DK-500P | DK-500P | 300 | .5 | Lead Reduction | ||
DK-600P | DK-600P | 300 | .5 | Lead Reduction | ||
DK-8001 | DK-8001 | 300 | .5 | Lead Reduction | ||
DK-9085 | DK-9085 | 300 | .5 | Lead Reduction | ||
DK-9690 | DK-9690 | 200 | .5 | Lead Reduction | ||
DK-GSWF | DK-GSWF | 300 | .5 | Lead Reduction | ||
DK-MWF | DK-MWF | 300 | .5 | Lead Reduction | ||
DK-RPWF | DK-RPWF | 300 | .5 | Lead Reduction |
TOP PURE (USA), Inc. | |
3717 San Gabriel River Parkway | |
Pico Rivera, CA 90660 | |
United States | |
1 6262389070 | |
Visit this company's website |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
RWFS0100AH | RWF0100AH | 300(1) | .42 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS0500AH | RWF0500AH | 300(1) | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS0600AH | RWF0600AH | 300(1) | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS0700AH | RWF0700AH | 300(1) | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS0900AH | RWF0900AH | 300(1) | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS1000AH | RWF1000AH | 300(1) | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS1100AH | RWF1100AH | 300(1) | .35 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS1200AH | RWF1200AH | 200(1) | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS3300AH | RWF3300AH | 300(1) | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS3500AH | RWF3500AH | 200(1) | .41 | Cyst Reduction Lead Reduction Mercury Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. |
Viking Range, LLC | |
111 Front Street | |
Greenwood, MS 38930 | |
United States | |
1-888-845-4641 | |
Visit this company's website |
Facility : West Haven, CT
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter [Pb] |
||||||
TruWater NGFC 2000 | RWFVRF | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Singapore
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
Prochill NGPT[Pb] | RWFVRF1 | 125(1) | .65 | 2,4-D Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction |
||
TruWater NGFC[Pb] | RWFVRF | 400(1) | .5 | 2,4-D Reduction Alachlor Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Whirlpool Corporation | |
2000 North M-63 | |
Benton Harbor, MI 49085 | |
United States | |
269-923-7688 |
Facility : # 1 Taiwan
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter |
||||||
EDR1RXD1B[2] [Pb] | EDR1RXD1B | 200(1) | .5 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Turbidity Reduction |
||
EDR2RXD1B[2] [Pb] | EDR2RXD1B | 200(1) | .6 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Turbidity Reduction |
||
EDR3RXD1B[2] [Pb] | EDR3RXD1B | 200(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
EDR5RXD1B[2] [Pb] | EDR5RXD1B | 240(1) | .5 | 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Lead Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction |
||
EVFILTER5[2] [Pb] | EVFILTER5 | 240 | .5 | Lead Reduction | ||
EVFILTER5B[2] [Pb] | EVFILTER5B | 240 | .5 | Lead Reduction | ||
FILTER1B[2] [Pb] | FILTER1B | 200(1) | .5 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Turbidity Reduction |
||
FILTER2B[2] [Pb] | FILTER2B | 200(1) | .6 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Turbidity Reduction |
||
FILTER3B[2] [Pb] | FILTER3B | 200(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
FILTER5B[2] [Pb] | FILTER5B | 240(1) | .5 | 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Lead Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction Turbidity Reduction |
||
P1WB2[2] [Pb] | WHR3RXD1[4] | 200(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
P1WB2[2] [Pb] | EDR3RXD1 | 200(1) | .5 | Asbestos Reduction MTBE Reduction Trihalomethanes (TTHM) Reduction Carbofuran Reduction VOC Reduction ** Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction |
||
P1WB2[2] [Pb] | KAD3RXD1[3] | 200(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
P1WB2L[2] [Pb] | EDR3RXD1 | 200(1) | .5 | Asbestos Reduction MTBE Reduction Trihalomethanes (TTHM) Reduction Carbofuran Reduction VOC Reduction ** Atrazine Reduction Benzene Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Turbidity Reduction |
||
P1WB2L[2] [Pb] | WHR3RXD1[4] | 200(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
P1WB2L[2] [Pb] | KADR3RXD1[3] | 200(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction Turbidity Reduction VOC Reduction ** |
||
P8WB2L[2] [Pb] | WHR1RXD1[4] | 200(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction VOC Reduction ** Turbidity Reduction |
||
P8WB2L[2] [Pb] | EDR1RXD1 | 200 | .50 | O-Dichlorobenzene Reduction Endrin Reduction Ethylbenzene Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Lead Reduction Toxaphene Reduction P-Dichlorobenzene Reduction Lindane Reduction Tetrachloroethylene Reduction Toluene Reduction Styrene Reduction 1,2,4-Trichlorobenzene Reduction Turbidity Reduction |
||
P8WB2L[2] [Pb] | KAD1RXD1[3] | 200(1) | .5 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction VOC Reduction ** Turbidity Reduction |
||
P9WB2L[2] [Pb] | WHR2RXD1[4] | 200(1) | .6 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction VOC Reduction ** Turbidity Reduction |
||
P9WB2L[2] [Pb] | EDR2RXD1 | 200 | .60 | O-Dichlorobenzene Reduction Endrin Reduction Ethylbenzene Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Lead Reduction Toxaphene Reduction P-Dichlorobenzene Reduction Lindane Reduction Tetrachloroethylene Reduction Toluene Reduction Styrene Reduction 1,2,4-Trichlorobenzene Reduction Turbidity Reduction |
||
P9WB2L[2] [Pb] | KAD2RXD1[3] | 200(1) | .6 | Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction MTBE Reduction Mercury Reduction O-Dichlorobenzene Reduction Tetrachloroethylene Reduction Toxaphene Reduction Trihalomethanes (TTHM) Reduction VOC Reduction ** Turbidity Reduction |
||
PWF-NL240V[2] [Pb] | EDR5RXD1 | 240(1) | .5 | Benzene Reduction Carbofuran Reduction Lead Reduction Mercury Reduction P-Dichlorobenzene Reduction Toxaphene Reduction 2,4-D Reduction Atrazine Reduction Cyst Reduction Asbestos Reduction Turbidity Reduction |
||
W11602565[2] [5] [Pb] | EDR1RXD1 | 100(1) | .5 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Turbidity Reduction |
||
W11602565[2] [5] [Pb] | WHR1RXD1[4] | 100(1) | .5 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Turbidity Reduction |
||
W11602565[2] [5] [Pb] | KAD1RXD1[3] | 100(1) | .5 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Turbidity Reduction |
||
W11602799[2] [5] [Pb] | WHR2RXD1[4] | 100(1) | .60 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Turbidity Reduction |
||
W11602799[2] [5] [Pb] | EDR2RXD1 | 100(1) | .6 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Turbidity Reduction |
||
W11602799[2] [5] [Pb] | KAD2RXD1[3] | 100(1) | .60 | 1,2,4-Trichlorobenzene Reduction 2,4-D Reduction Asbestos Reduction Atrazine Reduction Benzene Reduction Carbofuran Reduction Cyst Reduction Endrin Reduction Ethylbenzene Reduction Lead Reduction Lindane Reduction O-Dichlorobenzene Reduction P-Dichlorobenzene Reduction Styrene Reduction Tetrachloroethylene Reduction Toluene Reduction Toxaphene Reduction Turbidity Reduction |
||
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. [2] Product is authorized to bear the NSF and/or the cNSFus Mark. [3] KitchenAid® [4] Whirlpool® [5] W11602565 and W11602799 without Performance Indicator Device. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
YUNDA H&H TECH (Tianjin) Co., Ltd. | |
No.29, Jinhai Road | |
Jinghai, Tianjin 301600 | |
China | |
Visit this company's website |
Facility : Tianjin, China
Replacement | Service Cycle | Flow Rate | ||||
Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
Refrigerator Filter[1] |
||||||
RFS3902[Pb] | 7440 011 | 300 | .47 | Cyst Reduction Lead Reduction |
||
RWFS0100AH | RWF0100AH | 300 | .42 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS0500AH | RWF0500AH | 300 | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS0600AH | RWF0600AH | 300 | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS0700AH | RWF0700AH | 300 | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS0900AH | RWF0900AH | 300 | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS1000AH | RWF1000AH | 300 | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS1100AH | RWF1100AH | 300 | .35 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS1200AH | RWF1200AH | 200 | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS3000AH | RWF3000AH | 300 | .47 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS3300ABH | RWF3300ABH | 300 | .5 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS3500AH | RWF3500AH | 200 | .41 | Cyst Reduction Lead Reduction Mercury Reduction |
||
RWFS3600AH | RWF3600AH | 200 | .3 | Cyst Reduction Lead Reduction Mercury Reduction |
||
  [1] Claims of capacity or rated service cycle are not applicable for mechanical filtration. [Pb] Product also evaluated and determined to possess weighted average lead content of <=0.25% and complies with lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Number of matching Manufacturers is 19
Number of matching Products is 146