NSF Product and Service Listings

These NSF Official Listings are current as of Wednesday, April 16, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?ProductFunction=058%7CArsenic+%28Pentavalent%29%3C%3D50+ppb+Reduction&

Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.


NSF/ANSI 58
Reverse Osmosis Drinking Water Treatment Systems



Everpure LLC 
1040 Muirfield Drive
Hanover Park, IL 60133 
United States 
800-323-7873 
Visit this company's website

Facility : Hanover Park, IL

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap
Conserv 75E[Pb] 4CC
GRO-75EN
4FC5
4CB5
  50.51   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
Conserv 75S[Pb] 4CC
GRO-75EN
4FC5
  50.51   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
LVRO-75HE GRO-75EN
2FC5-S
2CB5
  14.66   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
LVRO-75HE+F GRO-75EN
2FC5-S
2CB5
  14.66   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[1] Certified for use with HE-II Upgrade Pump Kit Retro.
[2] System is Certified with optional 2nd RO Membrane Kit EV9970-00 or EV9969-00.
    
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


Facility : Roselle, IL

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap [Pb]
Conserv 75E 4CB5
4CC
4FC5
GRO-75EN
  50.51   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
Conserv 75S 4CC
4FC5
GRO-75EN
  50.51   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
LVRO-75HE 2CB5
2FC5-S
GRO-75EN
  14.66   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
LVRO-75HE+F 2CB5
2FC5-S
GRO-75EN
  14.66   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[1] Certified for use with HE-II Upgrade Pump Kit Retro.
[2] System is Certified with optional 2nd RO Membrane Kit EV9970-00 or EV9969-00.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.



 
Pentair Residential Filtration, LLC 
13845 Bishops Drive
Suite 200 
Brookfield, WI 53005 
United States 
800-279-9404 
262-238-4400

Facility : Roselle, IL

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap
Everpure Residential ROM IV[Pb] ROM-G75
ROM-PFK
ROM-PRE
ROM-PST
  14.66   Turbidity Reduction
Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


Facility : Jiangsu Province, China

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap [Pb]
OmniFilter RO2050[1] [2] CB1
OM1
R200 Series A
ROR2000
RS14
ROR2050
  15.04   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction
Pentair GRO-350B FDF1-RC
GRO50-RC
F1GC-RC
  14.96   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
Turbidity Reduction
TDS Reduction
Nitrate/Nitrite Reduction
Pentair GRO-475B FDF1-RC
GRO75-RC
F1B1-RC
F1GC-RC
  21.08   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
Turbidity Reduction
TDS Reduction
Pentair GRO-475BP FDF1-RC
GRO75-RC
F1B1-RC
F1GC-RC
  94.38   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
Turbidity Reduction
TDS Reduction
Pentair GRO-575B FDF1-RC
GRO75-RC
F2B2-RC2
F1GC-RC
F2B1-RC
  21.08   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
Turbidity Reduction
TDS Reduction
Pentair RO-2550 TLC-50
P5
EPM-10
GS-10RO
  15.04   Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[1] ROR2000 is a replacement kit containing RS14, CB1, and two o-rings.					
[2] ROR2050 is a replacement kit containing R200, CB1, RS14, and two o-rings.
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

NOTE: These components do not bear the NSF Mark.  Evidence of Certification will appear on the
      manufacturer's literature and packaging.

Number of matching Manufacturers is 2
Number of matching Products is 15
Processing time was 1 seconds