NSF/ANSI 42
Drinking Water Treatment Units - Aesthetic Effects
Drinking Water Treatment Units - Aesthetic Effects
| Water Channel Partners | |
| 2805 Dodd Road | |
| Suite 300 | |
| Eagan, MN 55121 | |
| United States | |
| 800-869-2837 |
Facility : # 2 USA
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Point-of-Entry[1] [Pb] [POE] |
||||||
| Ecopure EPHS | N/A | 570,000 | 8 | Chlorine Reduction Taste and Odor Reduction |
||
| Ecopure EPHY | N/A | 570,000 | 6.5 | Chlorine Reduction Taste and Odor Reduction |
||
| Ecopure EPWHCW | N/A | 570,000 | 6 | Chlorine Reduction Taste and Odor Reduction |
||
|
  [1] Product also complies with NSF/ANSI Std 372.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
[POE] Product conforms to NSF/ANSI/CAN 61 health effects requirements.
|
||||||
Facility : # 3 USA
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Plumbed-In [Pb] |
||||||
| Ecopure EPINL30 | N/A | 2500 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
| Ecopure EPINL35 | N/A | 2500 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
| Ecopure EPINL40 | N/A | 2000 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
| Ecopure EPWPFF | EPWPRF | 2000(1) | 1.8 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
| Ecopure EPWRSS | EPWRSF | 750(1) | 0.5 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| Ecopure ECOP20 | ECODWF | 270 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
| Ecopure ECOP30[4] | ECOROF | 3850 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
| Ecopure EPWUFF | EPWUFR | 2000(1) | 2 | Chlorine Reduction Taste and Odor Reduction Nominal Particulate Reduction, Class I |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[4] Model is a reverse osmosis system and is also Certified to NSF/ANSI Standard 58.
[5] As of 12/06/2022.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
Point-of-Entry [Pb] [POE] |
||||||
| Ecopure EPAWCS | EPAWCF | 10,000(1) | 4 | Chlorine Reduction Nominal Particulate Reduction, Class III Taste and Odor Reduction |
||
| Ecopure EPWHE | EPWHEF | 10,000(1) | 4 | Chlorine Reduction Nominal Particulate Reduction, Class III Taste and Odor Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
[POE] Product conforms to NSF/ANSI/CAN 61 health effects requirements.
|
||||||
|
Refrigerator Filter[Pb] |
||||||
| Ecopure EPINL20 | N/A | 1350 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
|
  [Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
Replacement Element: Plumbed-In to Separate Tap [Pb] |
||||||
| Ecopure EPU2C[6] | N/A | 3000 | 1 | Chlorine Reduction Taste and Odor Reduction |
||
|
  [6] EPU3/EPU2C.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
NSF/ANSI 44
Cation Exchange Water Softeners
Cation Exchange Water Softeners
| Water Channel Partners | |
| 2805 Dodd Road | |
| Suite 300 | |
| Eagan, MN 55121 | |
| United States | |
| 800-869-2837 |
Facility : # 2 USA
| Flow Rate | ||||||
| Brand Name / Trade Name / Model | (gpm) | Claim | ||||
|
Point-of-Entry [1] [Pb] [POE] |
||||||
| Ecopure EP 6130[2] | 7.3 | Hardness Reduction[HR] Efficiency Rated[ER] |
||||
| Ecopure EP30[2] | 7 | Hardness Reduction[HR] Efficiency Rated[ER] |
||||
| Ecopure EP31[2] | 7.2 | Hardness Reduction[HR] Efficiency Rated[ER] |
||||
| Ecopure EP40[2] | 8.5 | Hardness Reduction[HR] Efficiency Rated[ER] |
||||
| Ecopure EP42[2] | 8.2 | Hardness Reduction[HR] Efficiency Rated[ER] |
||||
| Ecopure EPHS[2] | 8 | Efficiency Rated[ER] Hardness Reduction[HR] Barium Reduction Radium 226/228 Reduction |
||||
| Ecopure EPHY[2] | 6.5 | Efficiency Rated[ER] Hardness Reduction[HR] Barium Reduction Radium 226/228 Reduction |
||||
|
  [1] Product also complies with NSF/ANSI 372.
[1] Product also complies with NSF/ANSI 372.
[2] Product evaluated and determined to comply with efficiency rating requirements defined
by California state laws.
[ER] Softener Efficiency indicates that the softener achieves a minimum of 3,350 grains of
hardness removed per pound of regenerant salt (477 grams of hardness removed per
kilogram of regenerant salt), and also that it uses 5 gallons or less of regenerant
water per 1,000 grains of hardness removed (18.9 liters or less of regenerant water per
64.8 grams of hardness removed).
[HR] Hardness Reduction indicates that the published capacity ratings for reducing hardness
have been verified.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
[POE] Product conforms to NSF/ANSI/CAN 61 health effects requirements.
|
||||||
NSF/ANSI 53
Drinking Water Treatment Units - Health Effects
Drinking Water Treatment Units - Health Effects
| Water Channel Partners | |
| 2805 Dodd Road | |
| Suite 300 | |
| Eagan, MN 55121 | |
| United States | |
| 800-869-2837 |
Facility : # 3 USA
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Plumbed-In [Pb] |
||||||
| Ecopure EPINL40 | N/A | 2000(1) | .5 | Cyst Reduction Lead Reduction |
||
| Ecopure EPWPFF | EPWPRF | 2000(1) | 1.8 | Benzene Reduction Cyst Reduction Lead Reduction Mercury Reduction |
||
| Ecopure EPWRSS | EPWRSF | 750(1) | .5 | Cyst Reduction Lead Reduction Atrazine Reduction Lindane Reduction Turbidity Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| Ecopure ECOP20 | ECODWF | 270(1) | .5 | Cyst Reduction Lead Reduction MTBE Reduction VOC Reduction ** |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] As of 12/06/2022.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
NSF/ANSI 58
Reverse Osmosis Drinking Water Treatment Systems
Reverse Osmosis Drinking Water Treatment Systems
| Water Channel Partners | |
| 2805 Dodd Road | |
| Suite 300 | |
| Eagan, MN 55121 | |
| United States | |
| 800-869-2837 |
Facility : # 3 USA
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [1] [Pb] |
||||||
| Ecopure ECOP30 | ECOROM | 14.76 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] Model has a post filter that is also Certified to NSF/ANSI Standard 42.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
* This product is intended for use only on water supplies that have been shown to be at or below the referenced concentration and valency of arsenic.
CSA Standard B483.1
Drinking Water Treatment Systems
Drinking Water Treatment Systems
| Water Channel Partners | |
| 2805 Dodd Road | |
| Suite 300 | |
| Eagan, MN 55121 | |
| United States | |
| 800-869-2837 |
Facility : # 3 USA
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Plumbed-In [Pb] |
||||||
| Ecopure EPINL30 | N/A | 2500 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
| Ecopure EPINL35 | N/A | 2500 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
| Ecopure EPWPFF | EPWPRF | 2000(1) | 1.8 | Chlorine Reduction Nominal Particulate Reduction, Class III Taste and Odor Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| Ecopure ECOP20 | ECODWF | 270 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
| Ecopure ECOP30[2] | ECOROF | 3850 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
| Ecopure EPWUFF | EPWUFR | 2000(1) | 2 | Chlorine Reduction Nominal Particulate Reduction, Class I Taste and Odor Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] Model is a reverse osmosis system and is also Certified to NSF/ANSI Standard 58.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
Point-of-Entry [Pb] [POE] |
||||||
| Ecopure EPAWCS | EPAWCF | 10000(1) | 4 | Chlorine Reduction Nominal Particulate Reduction, Class III Taste and Odor Reduction |
||
| Ecopure EPWHE | EPWHEF | 10000(1) | 4 | Chlorine Reduction Nominal Particulate Reduction, Class III Taste and Odor Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
[POE] Product conforms to NSF/ANSI/CAN 61 health effects requirements.
|
||||||
|
Refrigerator Filter[Pb] |
||||||
| Ecopure EPINL20 | N/A | 1350 | .5 | Chlorine Reduction Taste and Odor Reduction |
||
|
  [Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Plumbed-In [Pb] |
||||||
| Ecopure EPWPFF | EPWPRF | 2000(1) | 1.8 | Benzene Reduction Cyst Reduction Lead Reduction Mercury Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
|
Plumbed-In to Separate Tap [Pb] |
||||||
| Ecopure ECOP20 | ECODWF | 270(1) | .5 | Cyst Reduction Lead Reduction MTBE Reduction VOC Reduction ** |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
| Replacement | Daily Production | |||||
| Brand Name / Trade Name / Model | Module | Rate (gpd) | Claim | |||
|
Plumbed-In to Separate Tap [1] [Pb] |
||||||
| Ecopure ECOP30 | ECOROM | 14.76 | Arsenic (Pentavalent)<=300 ppb Reduction* Barium Reduction Cadmium Reduction Chromium (Hexavalent) Reduction Chromium (Trivalent) Reduction Copper Reduction Cyst Reduction Fluoride Reduction Lead Reduction Nitrate/Nitrite Reduction Radium 226/228 Reduction Selenium Reduction TDS Reduction Turbidity Reduction |
|||
|
  * This product is intended for use only on water supplies that have been shown to be at or
below the referenced concentration and valency of arsenic.
[1] Model has a post filter that is also Certified to NSF/ANSI Standard 42.
[Pb] Product also evaluated and determined to possess weighted average lead content of
<=0.25% and complies with lead content requirements for “lead free” plumbing as defined
by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
Water Act.
|
||||||
** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Number of matching Manufacturers is 5
Number of matching Products is 39
Processing time was 0 seconds