NSF Product and Service Listings

These NSF Official Listings are current as of Monday, November 2, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/DWTU/Listings.asp?TradeName=everpure&hdModlStd=ModlStd&

Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.


NSF/ANSI 42
Drinking Water Treatment Units - Aesthetic Effects


Everpure LLC 
1040 Muirfield Drive
Hanover Park, IL 60133 
United States 
800-323-7873 
Visit this company's website

Facility : Caldwell, ID

 
           

COMPONENTS: Filter Cartridges[1] [Pb]
Everpure CTOS-Q  
Everpure CTOS-Q10  

   
[1] Conforms to material requirements only. 
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


Facility : Roselle, IL

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [G]
Everpure FX-11 CTO-10 15,000 1.5   Chlorine Reduction
Nominal Particulate Reduction, Class III
Taste and Odor Reduction
Everpure FX-12 CTO-20 30,000 3   Chlorine Reduction
Nominal Particulate Reduction, Class III
Taste and Odor Reduction
Everpure FXI-11 CTOS-10 15,000 1.5   Chlorine Reduction
Nominal Particulate Reduction, Class III
Taste and Odor Reduction
Everpure FXI-12 CTOS-20 30,000 3   Chlorine Reduction
Nominal Particulate Reduction, Class III
Taste and Odor Reduction
Everpure FXI-22 CTOS-20
S5-20
30,000 3   Chlorine Reduction
Nominal Particulate Reduction, Class III
Taste and Odor Reduction
Everpure QTCR-1 CTO-QCR2 10,000(1) 1.7   Chlorine Reduction
Nominal Particulate Reduction, Class III
Taste and Odor Reduction
Chloramine Reduction
Everpure QTCR-2 CTO-QCR2 20,000(1) 3.4   Chlorine Reduction
Nominal Particulate Reduction, Class III
Taste and Odor Reduction
Chloramine Reduction
Everpure QTCR-3 CTO-QCR2 30,000(1) 5.1   Chlorine Reduction
Nominal Particulate Reduction, Class III
Taste and Odor Reduction
Chloramine Reduction
Everpure QTCR-4 CTO-QCR2 40,000(1) 6.8   Chlorine Reduction
Nominal Particulate Reduction, Class III
Taste and Odor Reduction
Chloramine Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[4] From date code 1C38
[5] From date code 1C48
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

COMPONENTS: Filter Cartridges[2] [G]
Everpure CTO-10  
Everpure CTO-20  
Everpure CTO-Q  
Everpure CTO-Q10  
Everpure CTOS-10  
Everpure CTOS-20  
Everpure S5-10  
Everpure S5-20  

   
[2] Conforms to material requirements only.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.



 
Pentair Residential Filtration, LLC 
13845 Bishops Drive
Suite 200 
Brookfield, WI 53005 
United States 
800-279-9404 
262-238-4400

Facility : Hanover Park, IL

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [G]
Everpure Residential EF-1500 EF-1500 1500(1) 2.2   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
Everpure Residential EF-3000 EF-3000 3000(1) 2.2   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
Everpure Residential EF-6000 EF-6000 6000(1) 1.67   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
Everpure Residential H-104 Filter[2] [3] H-104 1000(1) .5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
Everpure Residential H-300 Filter[2] [3] H-300 300(1) .5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
Everpure Residential H-300-NXT H-300-NXT 300(1) .5   Chlorine Reduction
Taste and Odor Reduction
Nominal Particulate Reduction, Class I
Everpure Residential H-54 Filter[2] [3] H-54 750(1) .5   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
Everpure Residential PBS-400 PBS-400 3000(1) 2.2   Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] From date code 1C38
[3] From date code 1C48
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Plumbed-In to Separate Tap [2] [3] [G]
Everpure Residential H-1200 H-1200 #1
H-1200 #2
1000(1) .5   Chloramine Reduction
Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] From date code 1C38
[3] From date code 1C48
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


Facility : Roselle, IL

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In to Separate Tap [2] [3] [G]
Everpure Residential H-1200 H-1200 #1
H-1200 #2
1000(1) .5   Chloramine Reduction
Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] From date code 1C38
[3] From date code 1C48
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


NSF/ANSI 53
Drinking Water Treatment Units - Health Effects



 
Pentair Residential Filtration, LLC 
13845 Bishops Drive
Suite 200 
Brookfield, WI 53005 
United States 
800-279-9404 
262-238-4400

Facility : Hanover Park, IL

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [G]
Everpure Residential EF-1500 EF-1500 1500(1) 2.2   Cyst Reduction
Lead Reduction
Everpure Residential EF-3000 EF-3000 3000(1) 2.2   Cyst Reduction
Lead Reduction
Everpure Residential EF-6000 EF-6000 6000(1) 1.67   Cyst Reduction
Lead Reduction
Everpure Residential H-104 Filter[2] [3] H-104 1000(1) .5   Cyst Reduction
Lead Reduction
Everpure Residential H-300 Filter[2] [3] H-300 300(1) .5   Cyst Reduction
Lead Reduction
VOC Reduction **
Everpure Residential H-300-NXT H-300-NXT 300(1) .5   Cyst Reduction
Lead Reduction
Everpure Residential H-54 Filter[2] [3] H-54 750(1) .5   Cyst Reduction
Lead Reduction
Everpure Residential PBS-400 PBS-400 3000(1) 2.2   Cyst Reduction
Lead Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] From date code 1C38
[3] From date code 1C48
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Plumbed-In to Separate Tap [2] [3] [G]
Everpure Residential H-1200 H-1200 #1
H-1200 #2
1000(1) .5   Cyst Reduction
Lead Reduction
MTBE Reduction
VOC Reduction **

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[2] From date code 1C38
[3] From date code 1C48
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

NSF/ANSI 58
Reverse Osmosis Drinking Water Treatment Systems



 
Pentair Residential Filtration, LLC 
13845 Bishops Drive
Suite 200 
Brookfield, WI 53005 
United States 
800-279-9404 
262-238-4400

Facility : Hanover Park, IL

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap
Everpure Residential ROM IV[G] ROM-PRE
ROM-G75
ROM-PST
ROM-PFK
  14.66   Arsenic (Pentavalent)<=300 ppb Reduction*
Barium Reduction
Cadmium Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Chromium (Hexavalent) Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Chromium (Trivalent) Reduction
Turbidity Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


Facility : Roselle, IL

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap
Everpure Residential ROM IV[G] ROM-G75
ROM-PFK
ROM-PRE
ROM-PST
  14.66   Turbidity Reduction
Arsenic (Pentavalent)<=50 ppb Reduction*
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction

   
* This product is intended for use only on water supplies that have been shown to be at or
  below the referenced concentration and valency of arsenic.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


NSF/ANSI 401
Drinking Water Treatment Units - Emerging Compounds/Incidental Contaminants



 
Pentair Residential Filtration, LLC 
13845 Bishops Drive
Suite 200 
Brookfield, WI 53005 
United States 
800-279-9404 
262-238-4400

Facility : Hanover Park, IL

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In [G]
EVERPURE RESIDENTIAL H-104 H-104 1000(1) .5   Microplastics Reduction
EVERPURE RESIDENTIAL H-54 H-54 750(1) .5   Microplastics Reduction
Everpure Residential EF-1500 EF-1500 (1) 2.2   Microplastics Reduction
Everpure Residential EF-3000 EF-3000 (1) 2.2   Microplastics Reduction
Everpure Residential EF-6000 EF-6000 (1) 1.67   Microplastics Reduction
Everpure Residential H-300 Filter H-300 (1) .5   Microplastics Reduction
Everpure Residential H-300-NXT H-300-NXT 300(1) .5   Bisphenol A Reduction
Estrone Reduction
Ibuprofen Reduction
Naproxen Reduction
Nonylphenol Reduction
Phenytoin Reduction
Microplastics Reduction
Everpure Residential H-54 Filter H-54 (1) .5   Microplastics Reduction
Everpure Residential PBS-400 PBS-400 (1) 2.2   Microplastics Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Plumbed-In to Separate Tap [G]
Everpure Residential H-1200 H-1200 #1
H-1200 #2
(1) 0.5   Microplastics Reduction

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


ASSE 1087
Commercial and Food Service Water Treatment Equipment
Utilizing Drinking Water



Everpure LLC 
1040 Muirfield Drive
Hanover Park, IL 60133 
United States 
800-323-7873 
Visit this company's website

Facility : Caldwell, ID


COMPONENTS: Filter Cartridges[1] [G]
Everpure CTOS-Q  
Everpure CTOS-Q10  

   
[1] Conforms to material requirements only.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


Facility : Roselle, IL


COMPONENTS: Filter Cartridges[1] [G]
Everpure CTO-10  
Everpure CTO-20  
Everpure CTO-Q  
Everpure CTO-Q10  
Everpure CTOS-10  
Everpure CTOS-20  
Everpure S5-10  
Everpure S5-20  

   
[1] Conforms to material requirements only.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Plumbed-In[G]
Everpure FX-11  
Everpure FX-12  
Everpure FXI-11  
Everpure FXI-12  
Everpure FXI-22  
Everpure QTCR-1  
Everpure QTCR-2  
Everpure QTCR-3  
Everpure QTCR-4  

   
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


CSA Standard B483.1
Drinking Water Treatment Systems



 
Pentair Residential Filtration, LLC 
13845 Bishops Drive
Suite 200 
Brookfield, WI 53005 
United States 
800-279-9404 
262-238-4400

Facility : Roselle, IL

  Replacement Service Cycle Flow Rate  
Brand Name / Trade Name / Model Element (gallons) (gpm)   Claim

Plumbed-In to Separate Tap
Everpure Residential H-1200 H-1200 #1
H-1200 #2
1000(1) .5   Chloramine Reduction
Chlorine Reduction
Nominal Particulate Reduction, Class I
Taste and Odor Reduction
Cyst Reduction
Lead Reduction
MTBE Reduction
VOC Reduction **

   
(1) Claims of capacity or rated service cycle are not applicable for mechanical filtration.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

Facility : Hanover Park, IL

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap
Everpure Residential ROM IV[G] ROM-PRE
ROM-G75
ROM-PST
ROM-PFK
  14.66   Arsenic (Pentavalent)<=300 ppb Reduction
Barium Reduction
Cadmium Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Chromium (Hexavalent) Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Chromium (Trivalent) Reduction
Turbidity Reduction

   
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

Facility : Roselle, IL

  Replacement   Daily Production  
Brand Name / Trade Name / Model Module   Rate (gpd)   Claim

Plumbed-In to Separate Tap
Everpure Residential ROM IV[G] ROM-G75
ROM-PFK
ROM-PRE
ROM-PST
  14.66   Arsenic (Pentavalent)<=50 ppb Reduction
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent) Reduction
Chromium (Trivalent) Reduction
Copper Reduction
Cyst Reduction
Fluoride Reduction
Lead Reduction
Radium 226/228 Reduction
Selenium Reduction
TDS Reduction
Turbidity Reduction

   
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


** The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.

A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:

alachlor                      endrin                          simazine  
atrazine                      ethylbenzene                    styrene
benzene                       ethylene dibromide (EDB)        1,1,2,2-tetrachloroethane
carbofuran                    haloacetonitriles               tetrachloroethylene
carbon tetrachloride            bromochloroacetonitrile       toluene
chlorobenzene                   dibromoacetonitrile           2,4,5-TP(silvex)
chloropicrin                    dichloroacetonitrile          tribromoacetic acid
2,4-D                           trichloroacetonitrile         1,2,4-trichlorobenzene
dibromochloropropane (DBCP)   haloketones                     1,1,1-trichloroethane
o-dichlorobenzene               1,1-dichloro-2-propanone      1,1,2-trichloroethane
p-dichlorobenzene               1,1,1-trichloro-2-propanone   trichloroethylene 
1,2-dichloroethane            heptachlor                      trihalomethanes (TTHM)       
1,1-dichloroethylene          heptachlor epoxide                bromodichloromethane
cis-1,2-dichloroethylene      hexachlorobutadiene               bromoform
trans-1,2-dichloroethylene    hexachlorocyclopentadiene         chlorodibromomethane
1,2-dichloropropane           lindane                           chloroform
cis-1,3-dichloropropylene     methoxychlor                    xylenes                       
dinoseb                       pentachlorophenol                

Number of matching Manufacturers is 7
Number of matching Products is 72
Processing time was 0 seconds