NSF Product and Service Listings

These NSF Official Listings are current as of Thursday, June 4, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/fire_safety/Listings.asp?

Did you know?

The new NSF Product Listings website is available for NSF/ANSI 14-Certified products with a new look and feel. Click on "Try it Now" to check it out!

NSF/ANSI 14
Plastics Piping System Components and Related Materials


Click here for a list of End Use Code Designations.

Click on Product Standards or footnote in blue to view the referenced document



 
Atkore HDPE Pipe & Conduit 
4707 East Kearney Street
Springfield, MO 65803 
United States 
417-708-9887
Visit this company's website

Facility : Springfield, MO

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe+

PE 4710

Base-Line

FM 1613
2" - 16" IPS DR 7 (335 PC)
2" - 16" IPS DR 7.3 (320 PC)[1]

2" - 16" IPS DR 9 (250 PC)
2" - 16" IPS DR 11 (200 PC)
2" - 16" DIPS DR 7 (335 PC)
2" - 16" DIPS DR 7.3 (320 PC)[1]

2" - 16" DIPS DR 9 (250 PC)
2" - 16" DIPS DR 11 (200 PC)

[1] Special sizes may be acceptable for engineered applications, due to system conditions or
    special local requirements. It is the responsibility of the end user to ensure the
    product is suitable for the intended application.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+

PE 4710

Crystal-Line

FM 1613
2" - 16" IPS DR 7 (335 PC)
2" - 16" IPS DR 7.3 (320 PC)[1]

2" - 16" IPS DR 9 (250 PC)
2" - 16" IPS DR 11 (200 PC)
2" - 16" DIPS DR 7 (335 PC)
2" - 16" DIPS DR 7.3 (320 PC)[1]

2" - 16" DIPS DR 9 (250 PC)
2" - 16" DIPS DR 11 (200 PC)

[1] Special sizes may be acceptable for engineered applications, due to system conditions or
    special local requirements. It is the responsibility of the end user to ensure the
    product is suitable for the intended application.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+

PE 4710

Water-Line

FM 1613
2" - 16" IPS DR 7 (335 PC)
2" - 16" IPS DR 7.3 (320 PC)[1]

2" - 16" IPS DR 9 (250 PC)
2" - 16" IPS DR 11 (200 PC)
2" - 16" DIPS DR 7 (335 PC)
2" - 16" DIPS DR 7.3 (320 PC)[1]

2" - 16" DIPS DR 9 (250 PC)
2" - 16" DIPS DR 11 (200 PC)

[1] Special sizes may be acceptable for engineered applications, due to system conditions or
    special local requirements. It is the responsibility of the end user to ensure the
    product is suitable for the intended application.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.


Facility : Albuquerque, NM

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe+

PE 4710

Base-Line

FM 1613
2" - 24" IPS DR 7 (335 PC)
2" - 24" IPS DR 7.3 (320 PC)[1]

2" - 24" IPS DR 9 (250 PC)
2" - 24" IPS DR 11 (200 PC)
2" - 24" DIPS DR 7 (335 PC)
2" - 24" DIPS DR 7.3 (320 PC)[1]

2" - 24" DIPS DR 9 (250 PC)
2" - 24" DIPS DR 11 (200 PC)

[1] Special sizes may be acceptable for engineered applications, due to system conditions or
    special local requirements. It is the responsibility of the end user to ensure the
    product is suitable for the intended application.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+

PE 4710

Crystal-Line

FM 1613
2" - 24" IPS DR 7 (335 PC)
2" - 24" IPS DR 7.3 (320 PC)[1]

2" - 24" IPS DR 9 (250 PC)
2" - 24" IPS DR 11 (200 PC)
2" - 24" DIPS DR 7 (335 PC)
2" - 24" DIPS DR 7.3 (320 PC)[1]

2" - 24" DIPS DR 9 (250 PC)
2" - 24" DIPS DR 11 (200 PC)

[1] Special sizes may be acceptable for engineered applications, due to system conditions or
    special local requirements. It is the responsibility of the end user to ensure the
    product is suitable for the intended application.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+

PE 4710

Water-Line

FM 1613
2" - 24" IPS DR 7 (335 PC)
2" - 24" IPS DR 7.3 (320 PC)[1]

2" - 24" IPS DR 9 (250 PC)
2" - 24" IPS DR 11 (200 PC)
2" - 24" DIPS DR 7 (335 PC)
2" - 24" DIPS DR 7.3 (320 PC)[1]

2" - 24" DIPS DR 9 (250 PC)
2" - 24" DIPS DR 11 (200 PC)

[1] Special sizes may be acceptable for engineered applications, due to system conditions or
    special local requirements. It is the responsibility of the end user to ensure the
    product is suitable for the intended application.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.


Facility : Dallas, TX

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe+

PE 4710

Base-Line

FM 1613
2" - 6" IPS DR 7 (335 PC)
2" - 6" IPS DR 7.3 (320 PC)[1]

2" - 6" IPS DR 9 (250 PC)
2" - 6" IPS DR 11 (200 PC)
2" - 6" DIPS DR 7 (335 PC)
2" - 6" DIPS DR 7.3 (320 PC) [1]

2" - 6" DIPS DR 9 (250 PC)
2" - 6" DIPS DR 11 (200 PC)

[1] Special sizes may be acceptable for engineered applications, due to system conditions or
    special local requirements. It is the responsibility of the end user to ensure the
    product is suitable for the intended application.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+

PE 4710

Crystal-Line

FM 1613
2" - 6" IPS DR 7 (335 PC)
2" - 6" IPS DR 7.3 (320 PC)[1]

2" - 6" IPS DR 9 (250 PC)
2" - 6" IPS DR 11 (200 PC)
2" - 6" DIPS DR 7 (335 PC)
2" - 6" DIPS DR 7.3 (320 PC) [1]

2" - 6" DIPS DR 9 (250 PC)
2" - 6" DIPS DR 11 (200 PC)

[1] Special sizes may be acceptable for engineered applications, due to system conditions or
    special local requirements. It is the responsibility of the end user to ensure the
    product is suitable for the intended application.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+

PE 4710

Water-Line

FM 1613
2" - 6" IPS DR 7 (335 PC)
2" - 6" IPS DR 7.3 (320 PC)[1]

2" - 6" IPS DR 9 (250 PC)
2" - 6" IPS DR 11 (200 PC)
2" - 6" DIPS DR 7 (335 PC)
2" - 6" DIPS DR 7.3 (320 PC) [1]

2" - 6" DIPS DR 9 (250 PC)
2" - 6" DIPS DR 11 (200 PC)

[1] Special sizes may be acceptable for engineered applications, due to system conditions or
    special local requirements. It is the responsibility of the end user to ensure the
    product is suitable for the intended application.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.



 
Atkore Plastic Pipe Corporation 
16100 South Lanthrop Avenue
Harvey, IL 60426 
United States 
708-225-2075

Facility : Tampa, FL

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe+ [G]

PVC

Heritage Plastics

UL 1285
12" DR DR 14, DR 18, DR 25
10" DR DR 14, DR 18, DR 25
4" DR DR 14, DR 18, DR 25
8" DR DR 14, DR 18, DR 25
6" DR DR 14, DR 18, DR 25

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


Facility : Eugene, OR

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe+ [G]

PVC

Heritage Plastics

UL 1285
4" DR 14, 18, 25
6" DR 14, 18, 25
8" DR 14, 18, 25
10" DR 14, 18, 25
12" DR 14, 18, 25

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


Facility : Dallas, TX

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe+ [G]

PVC

Heritage Plastics

UL 1285
4" DR 14, 18, 25
6" DR 14, 18, 25
8" DR 14, 18, 25
10" DR 14, 18, 25
12" DR 14, 18, 25

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.



 
Bow Plumbing Group, Inc. 
5700 Cote de Liesse
Montreal, QC H4T 1B1 
Canada 
450-372-5481
Visit this company's website

Facility : # 2 Granby, Quebec, Canada

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing# [1] [2]

PEX

Bowpex

ASTM E84
1/2" (without insulation)

# Certified Bowpex tubing is natural, red, blue or white.
[1] Flame Spread Index <=25, Smoke Developed Index <=50.
    Flame Spread Index and Smoke Developed Index for ASTM E84 is based on minimum spacing of
    18 inches between tubing runs.  Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2
    FS25/SD50].
[2] May be marked with alternate trade designation "Wavin”.

Tubing# ¢ [2] [3]

PEX

Bowpex

CAN/ULC S102.2
1/2" (without insulation)

# Certified Bowpex tubing is natural, red, blue or white.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[2] May be marked with alternate trade designation "Wavin”.
[3] Flame Spread Value <=25, Smoke Developed Value <=50.
    Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2 FS25/SD50].

Tubing# ¢ [2] [4]

PEX

Bowpex

CAN/ULC S102.2
1/8", 1/4", 3/8", 3/4", 1" (with insulation)

# Certified Bowpex tubing is natural, red, blue or white.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[2] May be marked with alternate trade designation "Wavin”.
[4] Flame Spread Value <=25, Smoke Developed Value <=50.
    The Flame Spread Value and Smoke Developed Value is based on when tubing is field
    insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation as per Bow
    installation instructions.   Tubing shall be marked [cNSF®-fs ULCS102.2 FS25/SD50].

Tubing$ [1] [2]

PE-RT 4710

Enviro EXP

ASTM E84
1/2" (without insulation)

$ Certified Enviro EXP is coextruded natural tubing with a red, blue, or clear outer layer.
[1] Flame Spread Index <=25, Smoke Developed Index <=50.
    Flame Spread Index and Smoke Developed Index for ASTM E84 is based on minimum spacing of
    18 inches between tubing runs.  Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2
    FS25/SD50].
[2] May be marked with alternate trade designation "Wavin”.

Tubing$ [2] [5]

PE-RT 4710

Enviro EXP

ASTM E84
1/2", 3/4", 1" (with insulation)

$ Certified Enviro EXP is coextruded natural tubing with a red, blue, or clear outer layer.
[2] May be marked with alternate trade designation "Wavin”.
[5] Flame Spread Index <=25, Smoke Developed Index <=50.				
    Flame Spread Index and Smoke Developed Index for ASTM E84 is based on minimum spacing of
    18 inches between tubing runs.				
    1/2'', 3/4'' and 1'' tubing insulated with 1/2" JM Microlok HP Hi Performance fiberglass
    insulation per Bow instructions				
    Tubing shall be marked [NSF®-fs ASTM E84 FS = 25 / SD = 50].

Tubing$ ¢ [2] [3]

PE-RT 4710

Enviro EXP

CAN/ULC S102.2
1/2" (without insulation)

$ Certified Enviro EXP is coextruded natural tubing with a red, blue, or clear outer layer.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[2] May be marked with alternate trade designation "Wavin”.
[3] Flame Spread Value <=25, Smoke Developed Value <=50.
    Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2 FS25/SD50].

Tubing$ ¢ [2] [4]

PE-RT 4710

Enviro EXP

CAN/ULC S102.2
3/4" (without insulation)

$ Certified Enviro EXP is coextruded natural tubing with a red, blue, or clear outer layer.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[2] May be marked with alternate trade designation "Wavin”.
[4] Flame Spread Value <=25, Smoke Developed Value <=50.
    The Flame Spread Value and Smoke Developed Value is based on when tubing is field
    insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation as per Bow
    installation instructions.   Tubing shall be marked [cNSF®-fs ULCS102.2 FS25/SD50].

Tubing% [1] [2]

PEX

Oxypex

ASTM E84
1/2" (without insulation)

% Certified Oxypex tubing has a red outer layer.
[1] Flame Spread Index <=25, Smoke Developed Index <=50.
    Flame Spread Index and Smoke Developed Index for ASTM E84 is based on minimum spacing of
    18 inches between tubing runs.  Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2
    FS25/SD50].
[2] May be marked with alternate trade designation "Wavin”.

Tubing% ¢ [2] [3]

PEX

Oxypex

CAN/ULC S102.2
1/2" (without insulation)

% Certified Oxypex tubing has a red outer layer.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[2] May be marked with alternate trade designation "Wavin”.
[3] Flame Spread Value <=25, Smoke Developed Value <=50.
    Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2 FS25/SD50].

Tubing% ¢ [2] [4]

PEX

Oxypex

CAN/ULC S102.2
1/4", 3/8", 5/8", 3/4", 1" (with insulation)

% Certified Oxypex tubing has a red outer layer.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[2] May be marked with alternate trade designation "Wavin”.
[4] Flame Spread Value <=25, Smoke Developed Value <=50.
    The Flame Spread Value and Smoke Developed Value is based on when tubing is field
    insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation as per Bow
    installation instructions.   Tubing shall be marked [cNSF®-fs ULCS102.2 FS25/SD50].

Tubing@ [1] [2]

PEX

Superpex

ASTM E84
1/2" (without insulation)

@ Certified Bow Superpex tubing has a blue, red, or white outer layer.
[1] Flame Spread Index <=25, Smoke Developed Index <=50.
    Flame Spread Index and Smoke Developed Index for ASTM E84 is based on minimum spacing of
    18 inches between tubing runs.  Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2
    FS25/SD50].
[2] May be marked with alternate trade designation "Wavin”.

Tubing@ ¢ [2] [3]

PEX

Superpex

CAN/ULC S102.2
1/2" (without insulation)

@ Certified Bow Superpex tubing has a blue, red, or white outer layer.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[2] May be marked with alternate trade designation "Wavin”.
[3] Flame Spread Value <=25, Smoke Developed Value <=50.
    Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2 FS25/SD50].

Tubing@ ¢ [2] [4]

PEX

Superpex

CAN/ULC S102.2
1/4", 3/8", 3/4", 1" (with insulation)

@ Certified Bow Superpex tubing has a blue, red, or white outer layer.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[2] May be marked with alternate trade designation "Wavin”.
[4] Flame Spread Value <=25, Smoke Developed Value <=50.
    The Flame Spread Value and Smoke Developed Value is based on when tubing is field
    insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation as per Bow
    installation instructions.   Tubing shall be marked [cNSF®-fs ULCS102.2 FS25/SD50].



 
Calefactio Solutions Inc. 
30 Jean-Paul Cayer Street
Blainville, QC J7C 0N9 
Canada 
450-951-0818

Facility : # 1 China

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing[1] [2]

PEX

Calefactio

ASTM E84
1/8" - 3"[3]

[3] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[1] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[2]  Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
    red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[1] [4]

PEX

Calefactio

ASTM E84
1/8" - 3"[3]

[3] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[1] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[4] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.   Certified
    for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for
    red,  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.

Tubing[5] [6]

PEX

Calefactio

CAN/ULC S102.2
1/8" - 3"[3]

[3] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[6] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
    red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[4] [5]

PEX

Calefactio

CAN/ULC S102.2
1/8" - 3"[3]

[3] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.   Certified
    for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for
    red,  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
[5] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].



 
COFLEX , S.A DE C.V  
Hidalgo 602 pte
Monterrey, NLE 64000 
Mexico 
81 83892800

Facility : Guangdong, China

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing# $ * [2] [8]

PEX

Rifeng

ASTM E84
3/8", 1/2" - 2"

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
  
  
  
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
  
  
[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[8] ASTM E84, 1/2" - 2" The Flame Spread Index and Smoke Developed Index for 1/2" - 2"
    tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi
    performance fiberglass insulation as per RIFENG installation instructions. The 3/8"
    tubing is not insulated.

Tubing$ & [2] [9]

PEX

Rifeng

CAN/ULC S102.2
3/8", 1/2" - 2"

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
  
  
  
  
[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[9] 3/8" Tubing (without insulation) Tubing shall be marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50]. 1/2" through 2" Tubing (with insulation) Flame Spread Rating and Smoke
    Developed Classification based on when the tubing is field insulated with JM Microlok HP
    Hi Performance Fiberglass insulation as per the pipe manufacturer's installation
    instructions. Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[1] [3]

PEX

RIFENG PEX

ASTM E84
3/8" - 2"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[1] Certified for red and white PEX 5106 monowall pipe.
[3] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].

Tubing[1] [4]

PEX

RIFENG PEX

CAN/ULC S102.2
3/8" - 2"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[1] Certified for red and white PEX 5106 monowall pipe.
[4] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].

Tubing[5] [6]

PEX

RIFENG PEX

ASTM E84
3/8" - 1"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[6] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance installation instructions (all listed
    construction/color/size combinations greater than or equal to 3/8" in diameter). Flame
    Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between
    tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing[5] [7]

PEX

RIFENG PEX

CAN/ULC S102.2
3/8" - 1"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[7] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions (all listed construction/color/size
    combinations greater than or equal to 3/8" in diameter). Tubing shall be Marked
    [cNSF®-fs ULc S102.2 FS<=25/SD<=50].



 
Diamond Plastics Corporation 
1212 Johnstown Road
Grand Island, NE 68803 
United States 
308-384-4400

Facility : Casa Grande, AZ

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe+

PVC

DPC Pipe/ Diamond

FM 1612
PC 250: 4", 6", 8", 10", 12" DR 14
PC 185: 4", 6", 8", 10", 12" DR 18

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+

PVC

DPC Pipe/ Diamond

UL 1285
PC 165: 4",6",8",10",12",14",16",18",20",24"
PC 165: 30", 36"
PC 235: 4", 6", 8", 10", 12", 14", 16", 18", 20"
PC 235: 24", 30", 36"
PC 305: 4",6",8",10",12",14",16",18",20",24",30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.


Facility : Macon, GA

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe+

PVC

DPC Pipe/ Diamond

AWWA C900
4", 6", 8", 10", 12", 14", 16", 18", 20", 24", 30"
36", 42", 48"
PC305 (DR14) in nominal diameters of 4" - 30"
PC235 (DR18) in nominal diameters of 4" - 42"
PC200 (DR-21) in diameters 14" - 48"
PC165 (DR25) in diameters 4" - 60"
PC125 (DR32.5) in diameters 16" - 60"
PC100 (DR41) in diameters 20" - 60"
PC80 (DR51) in diameters 24" - 60"
PC50 (DR81) in diameters 36" - 60"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+

PVC

DPC Pipe/ Diamond

FM 1612
PC 250: 4", 6", 8", 10", 12" DR 14
PC 185: 4", 6", 8", 10", 12" DR 18

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+

PVC

DPC Pipe/ Diamond

UL 1285
PC 165: 4",6",8",10",12",14",16",18",20",24"
PC 165: 30", 36", 42"
PC 235: 4", 6", 8", 10", 12", 14", 16", 18", 20"
PC 235: 24", 30", 36", 42"
PC 305: 4",6",8",10",12",14",16",18",20"
PC 305: 24", 30", 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.


Facility : Muncie, IN

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe +

PVC

DPC Pipe/ Diamond

FM 1612
PC 250: 4", 6", 8", 10", 12" DR 14
PC 185: 4", 6", 8", 10", 12" DR 18

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe +

PVC

DPC Pipe/ Diamond

UL 1285
PC 165: 4", 6", 8", 10", 12", 14", 16", 18", 20"
PC 165: 24", 30"
PC 165: 38", 40", 42"
PC 235: 4", 6", 8", 10", 12", 14", 16", 18", 20"
PC 235: 24", 30"
PC 305: 4",6",8",10",12",14",16",18",20",24",30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

* Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Facility : Plaquemine, LA

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe +

PVC

DPC Pipe/ Diamond

FM 1612
PC 250: 4", 6", 8", 10", 12" DR 14
PC 185: 4", 6", 8", 10", 12" DR 18

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+

PVC

DPC Pipe/ Diamond

UL 1285
PC 165: 4",6",8",10",12",14",16",18",20",24"
PC 165: 30"
PC 235: 4", 6", 8", 10", 12", 14", 16", 18", 20"
PC 235: 24", 30"
PC 305: 4",6",8",10",12",14",16",18",20",24",30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.


Facility : Grand Island, NE

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe+

PVC

DPC Pipe/ Diamond

AWWA C900
4", 6", 8", 10", 12", 14", 16", 18", 20", 24", 30"
36", 42", 48", 54", 60"
PC305 (DR14) in nominal diameters of 4" - 30"
PC235 (DR18) in nominal diameters of 4" - 42"
PC200 (DR-21) in diameters 14" - 48"
PC165 (DR25) in diameters 4" - 60"
PC125 (DR32.5) in diameters 16" - 60"
PC100 (DR41) in diameters 20" - 60"
PC80 (DR51) in diameters 24" - 60"
PC50 (DR81) in diameters 36" - 60"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+

PVC

DPC Pipe/ Diamond/ Diamon Lok-21

FM 1612
PC 250: 4", 6", 8", 10", 12" DR 14
PC 185: 4", 6", 8", 10", 12" DR 18

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+

PVC

DPC Pipe/ Diamond

UL 1285
PC 165: 4",6",8",10",12",14",16",18",20",24"
PC 165: 30", 36"
PC 235: 4", 6", 8", 10", 12", 14", 16", 18", 20"
PC 235: 24", 30", 36", 42"
PC 305: 4",6",8",10",12",14",16",18",20"
PC 305: 24", 30", 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.


Facility : Golconda, NV

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe+

PVC

DPC Pipe/ Diamond

FM 1612
PC 250: 4", 6", 8", 10", 12" DR 14
PC 185: 4", 6", 8", 10", 12" DR 18

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+

PVC

DPC Pipe/ Diamond

UL 1285
PC 165: 4",6",8",10",12",14",16",18",20",24"
PC 165: 30", 36", 42"
PC 235: 4", 6", 8", 10", 12", 14", 16", 18", 20"
PC 235: 24", 30", 36", 42"
PC 305: 4",6",8",10",12",14",16",18",20"
PC 305: 24", 30", 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.


Facility : Lubbock, TX

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe+

PVC

DPC Pipe/ Diamond/ Diamond Lok-21

FM 1612
PC 250: 4", 6", 8", 10", 12" DR 14
PC 185: 4", 6", 8", 10", 12" DR 18

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+

PVC

DPC Pipe/ Diamond

UL 1285
PC 165: 4",6",8",10",12",14",16",18",20",24"
PC 165: 30", 36"
PC 235: 4", 6", 8", 10", 12", 14", 16", 18", 20"
PC 235: 24", 30", 36"
PC 305: 4",6",8",10",12",14",16",18",20"
PC 305: 24", 30", 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.



 
Empresa Mexicana de Manufacturas S.A. de C.V. DBA EMMSA 
AV Pedro Ramirez Vazquez Numero Exterior
200-13 Numero Interior Piso 5 Colonia 
Valle Oriente, San Pedro Garza Garcia 
Nuevo Léon 66269,  
Mexico 
52 818 088 7495
Visit this company's website

Facility : Garcia, Nuevo Leon, Mexico

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe# + [G]

PVC

EMMSA

FM 1612
4" SDR 14, 18
6" SDR 14, 18
8" SDR 14, 18
10" SDR 14, 18
12" SDR 14, 18

# This product may be marked with an alternate trade name: CRESCO; [CRESCO logo] or
  Durafort by CRESCO and/or [Durafort by CESCO logo].
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Pipe# + [G]

PVC

EMMSA

UL 1285
4" SDR 14, 18, 25
6" SDR 14, 18, 25
8" SDR 14, 18, 25
10" SDR 14, 18, 25
12" SDR 14, 18, 25

# This product may be marked with an alternate trade name: CRESCO; [CRESCO logo] or
  Durafort by CRESCO and/or [Durafort by CESCO logo].
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

NOTE: Only products bearing the NSF Mark are Certified.


 
Everhot Inc. 
5407 Foster Avenue
Brooklyn, NY 11234 
United States 
347-492-7660

Facility : # 1 China

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing# $ *

PEX

Everhot

ASTM E84

3/8", 1/2" - 2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing$ &

PEX

Everhot

CAN/ULC S102.2

3/8", 1/2" - 2"
Flame Spread Rating <= 25 Smoke Developed Classification <= 50

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].



 
Georg Fischer LLC 
9271 Jeronimo Road
Irvine, CA 92618 
United States 
610-252-7355
Visit this company's website

Facility : Little Rock, AR

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Fittings*** +++ [G]

CPVC

+GF+ or GSR

SE 31699

45° Ell, S x S
9817-xxx

90° Ell, S x S
9806-xxx

Cap, S
9847-xxx

Coupling, S x S
9829-xxx

Reducer Bushing, Spg x S
9837-xxx

Reducer Coupling, S x S
9829-xxx

Reducing Tee, S x S x S
9801-xxx

Tee, S x S x S
9801-xxx

*** xxx Suffix designates nominal size
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


Facility : Bakersfield, CA

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe$

CPVC 4120

ChlorFIT®

SE 31699
3" - 24" Sch 80

$ Socket bell ends are not tested or Listed by NSF for this production facility.

Pipe$

CPVC 4120

.+GF+ HARVEL CPVC

SE 31699
3"-24" Sch 80

$ Socket bell ends are not tested or Listed by NSF for this production facility.

Pipe$

CPVC 4120

.+GF+ Uponor ChlorFIT®

SE 31699
3"-24" Sch 80

$ Socket bell ends are not tested or Listed by NSF for this production facility.

Pipe$

CPVC 4120


SE 31699
3"-24" Sch 80

$ Socket bell ends are not tested or Listed by NSF for this production facility.

Pipe$

CPVC 4120

SeaCor®

SE 31699
3"-24" Sch 80

$ Socket bell ends are not tested or Listed by NSF for this production facility.


Facility : Easton, PA

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe$

CPVC 4120

ChlorFIT®

SE 31699
3"-24" Sch 80

$ Socket bell ends are not tested or Listed by NSF for this production facility.

Pipe$

CPVC 4120

.+GF+ HARVEL CPVC

SE 31699
3"-24" Sch 80

$ Socket bell ends are not tested or Listed by NSF for this production facility.

Pipe$

CPVC 4120

.+GF+ Uponor ChlorFIT®

SE 31699
3"-24" Sch 80

$ Socket bell ends are not tested or Listed by NSF for this production facility.

Pipe$

CPVC 4120


SE 31699
3"-24" Sch 80

$ Socket bell ends are not tested or Listed by NSF for this production facility.

Pipe$

CPVC 4120

SeaCor®

SE 31699
3"-24" Sch 80

$ Socket bell ends are not tested or Listed by NSF for this production facility.



 
GRUPO ALYADA SOCIEDAD ANONIMA 
Sabana Sur de la Contraloria 300
Mts Oeste y 75 Al Sur 
San José 10108 
Costa Rica 
506 84494767

Facility : # 1 China

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing# $ * [1] [2]

PEX

Alypex PEX-b

ASTM E84
3/8", 1/2" - 2"

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[2] ASTM E84, 1/2" - 2" The Flame Spread Index and Smoke Developed Index for 1/2" - 2"
    tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi
    performance fiberglass insulation as per RIFENG installation instructions. The 3/8"
    tubing is not insulated.

Tubing# $ * [1] [3]

PEX

Alypex PEX-b

CAN/ULC S102.2
3/8", 1/2" - 2"

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[3] 3/8" Tubing (without insulation)		
    Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].		
    1/2" through 2" Tubing (with insulation)		
    Flame Spread Rating and Smoke Developed Classification based on when the tubing is field
    insulated with JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].		
    

Tubing[1] [4] [5]

PEX

Alypex PEX-b

ASTM E84
3/8" - 2"

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] Certified for red and white PEX 5106 monowall pipe for Potable water application.	
    Certified for red and white PEX 5006 for Radiant Heat Flooring application.
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].		
    

Tubing[1] [4] [6]

PEX

Alypex PEX-b

CAN/ULC S102.2
3/8" - 2"

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] Certified for red and white PEX 5106 monowall pipe for Potable water application.	
    Certified for red and white PEX 5006 for Radiant Heat Flooring application.
[6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].

Tubing[1] [7] [8]

PEX

Alypex PEX-b

ASTM E84
3/8" - 1"

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[7] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer
    barrier	pipe for Potable water application. Certified for blue, red and white PPEX 5006
    2-layer skinned and 4-layer barrier for Radiant Heat Flooring application.
[8] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions (all listed construction/color/size combinations greater than
    or equal to 3/8" in diameter). Flame Spread Index and Smoke Developed Index based on 
    minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM
    E84 FS<=25/SD<=50].		
    

Tubing[1] [7] [9]

PEX

Alypex PEX-b

CAN/ULC S102.2
3/8" - 1"

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[7] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer
    barrier	pipe for Potable water application. Certified for blue, red and white PPEX 5006
    2-layer skinned and 4-layer barrier for Radiant Heat Flooring application.
[9] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with
    1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's
    installation
    instructions (all listed construction/color/size combinations greater than or equal to
    3/8" in
    diameter). Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].



 
Gulf Engineered Rubber and Plastics 
12-13 Green Street
Revesby 
Sydney, NSW 2212 
Australia 
61 2 9772 4877
Visit this company's website

Facility : Ho Chi Minh City, Vietnam

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Gasket+

SBR

N25102 (durometer 53)

FM 1612

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Gasket+

SBR

N26102 (durometer 60)

FM 1612

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Gasket+

EPDM

N55170 (durometer 53)

FM 1612

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Gasket+

EPDM

N56170 (durometer 60)

FM 1612

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.



 
Heatlink Group INC. 
11500 - Stonehill Drive NE
#115 
Calgary, AB T3N 2M7 
Canada 
403-717-3820

Facility : P3 USA

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing^ § **

PEX

PureLink Plus

ASTM E84
1/2", 3/4"

^ Flame Spread Index <= 25, Smoke Developed Index <= 50
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing^ § **

PEX

SureLink

ASTM E84
1/2", 3/4"

^ Flame Spread Index <= 25, Smoke Developed Index <= 50
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].


Fire Sprinkler Pipe and Fitting Systems

Product Type Material Type Trade Name Product Standard

Pipe and Fitting System% ** ¢

MLTPL

PureLink Plus *

ANSI/CAN/UL 1821

Adapter
3/4" PEX F1960 × 3/4" M/Sweat No Lead Brass Adapter (EX27122NL) 1" PEX F1960 × 1" M/Sweat No Lead Brass Adapter (EX27128NL) 1-1/4" PEX F1960 × 1-1/4" M/Sweat No Lead Brass Adapter (EX27135NL) 1-1/2" PEX F1960 × 1-1/2" M/Sweat No Lead Brass Adapter (EX27141NL)
2" PEX F1960 × 2" M/Sweat No Lead Brass Adapter (EX27154NL) 3/4" PEX F1960 × 3/4" F/Sweat No Lead Brass Adapter (EX27222NL) 1" PEX F1960 × 1" F/Sweat No Lead Brass Adapter (EX27228NL) 1-1/4" PEX F1960 × 1-1/4" F/Sweat No Lead Brass Adapter (EX27235NL)
1-1/2" PEX F1960 × 1-1/2" F/Sweat No Lead Brass Adapter (EX27241NL) 2" PEX F1960 × 2" F/Sweat No Lead Brass Adapter (EX27254NL) 3/4" PEX F1960 × 3/4" MNPT No Lead Brass Adapter (EX27522NL) 1" PEX F1960 × 1" MNPT No Lead Brass Adapter (EX27528NL)
1-1/4" PEX F1960 × 1-1/4" MNPT No Lead Brass Adapter (EX27535NL) N/A1-1/2" PEX F1960 × 1-1/2" MNPT No Lead Brass Adapter (EX27541NL) 2" PEX F1960 × 2" MNPT No Lead Brass Adapter (EX27554NL) 3/4" PEX F1960 × 3/4" FNPT No Lead Brass Adapter (EX27622NL)
1" PEX F1960 × 1" FNPT No Lead Brass Adapter (EX27628NL) 1-1/4" PEX F1960 × 1-1/4" FNPT No Lead Brass Adapter (EX27635NL) 1-1/2" PEX F1960 × 1-1/2" FNPT No Lead Brass Adapter (EX27641NL) 3/4" PEX F1960 × 1/2" M/Sweat No Lead Brass Adapter (EX27125NL)
N/A3/4" PEX F1960 × 1/2" F/Sweat No Lead Brass Adapter (EX27225NL) 3/4" PEX F1960 × 1/2" MNPT No Lead Brass Adapter (EX27525NL)

Coupling
3/4" × 3/4" PEX F1960 HPP Coupling (EX19022) 1" × 1" PEX F1960 HPP Coupling (EX19028) 1-1/4" × 1-1/4" PEX F1960 HPP Coupling (EX19035) 1-1/2" × 1-1/2" PEX F1960 HPP Coupling (EX19041)
2" × 2" PEX F1960 HPP Coupling (EX19054) 1-1/4" × 1" PEX F1960 HPP Coupling (EX19238) 1-1/2" × 1-1/4" PEX F1960 HPP Coupling (EX19243) 1-1/2" × 1" PEX F1960 HPP Coupling (EX19248)
2" × 1-1/2" PEX F1960 HPP Coupling (EX19264) 1" × 3/4" PEX F1960 HPP Coupling (EX19282) 3/4" × 1/2" PEX F1960 HPP Coupling (EX19225)

Elbow
3/4" × 3/4" PEX F1960 HPP Elbow EX18022 1" × 1" PEX F1960 HPP Elbow EX18028 1-1/4" × 1-1/4" PEX F1960 HPP Elbow EX18035 1-1/2" × 1-1/2" PEX F1960 HPP Elbow EX18041
2" × 2" PEX F1960 HPP Elbow EX18054

Expansion Rings
3/4" PEX F1960 HPP Expansion Ring 1" PEX F1960 HPP Expansion Ring 1-1/4" PEX F1960 HPP Expansion Ring 1-1/2" PEX F1960 HPP Expansion Ring
2" PEX F1960 HPP Expansion Ring

Plugs
3/4" PEX F1960 HPP Plug (EX15022) 1" PEX F1960 HPP Plug (EX15028) 1-1/4" PEX F1960 HPP Plug (EX15035) 1-1/2" PEX F1960 HPP Plug (EX15041)
2" PEX F1960 HPP Plug (EX15054)

Tees
3/4" × 3/4" × 3/4" PEX F1960 HPP Tee (EX16222) 1-1/4" × 1-1/4" × 3/4" PEX F1960 HPP Tee (EX16332) 1-1/4" × 1-1/4" × 1-1/4" PEX F1960 HPP Tee (EX16333) 1-1/4" × 1-1/4" × 1" PEX F1960 HPP Tee (EX16338)
1-1/4" × 1" × 3/4" PEX F1960 HPP Tee (EX16382) N1-1/4" × 1" × 1" PEX F1960 HPP Tee (EX16388) 1-1/2" × 1-1/4" × 3/4" PEX F1960 HPP Tee (EX16432) 1-1/2" × 1-1/4" × 1-1/4" PEX F1960 HPP Tee (EX16433)
1-1/2" × 1-1/4" × 1" PEX F1960 HPP Tee (EX16438) 1-1/2" × 1-1/2" × 3/4" PEX F1960 HPP Tee (EX16442) 1-1/2" × 1-1/2" × 1-1/4" PEX F1960 HPP Tee (EX16443) 1-1/2" × 1-1/2" × 1-1/2" PEX F1960 HPP Tee (EX16444)
1-1/2" × 1-1/2" × 1" PEX F1960 HPP Tee (EX16448) 1-1/2" × 1" × 1" PEX F1960 HPP Tee (EX16488) 2" × 1-1/2" × 3/4" PEX F1960 HPP Tee (EX16642) 2" × 1-1/2" × 1-1/4" PEX F1960 HPP Tee (EX16643)
2" × 1-1/2" × 1-1/2" PEX F1960 HPP Tee (EX16644) 2" × 1-1/2" × 1" PEX F1960 HPP Tee (EX16648) 2" × 2" × 3/4" PEX F1960 HPP Tee (EX16662) 2" × 2" × 1-1/4" PEX F1960 HPP Tee (EX16663)
2" × 2" × 1-1/2" PEX F1960 HPP Tee (EX16664) 2" × 2" × 2" PEX F1960 HPP Tee (EX16666) 2" × 2" × 1" PEX F1960 HPP Tee (EX16668) 1" × 3/4" × 3/4" PEX F1960 HPP Tee (EX16822)
1" × 3/4" × 1" PEX F1960 HPP Tee (EX16828) 1" × 1" × 3/4" PEX F1960 HPP Tee (EX16882) 1" × 1" × 1" PEX F1960 HPP Tee (EX16888) 3/4" × 3/4" × 1/2" PEX F1960 HPP Tee (EX16225)
3/4" × 1/2" × 3/4" PEX F1960 HPP Tee (EX16252) 3/4" × 1/2" × 1/2" PEX F1960 HPP Tee (EX16255) 1-1/4" × 1-1/4" × 1/2" PEX F1960 HPP Tee (EX16335) 1-1/2" × 1-1/2" × 1/2" PEX F1960 HPP Tee (EX16445)
1/2" × 1/2" × 3/4" PEX F1960 HPP Tee (EX16552) 2" × 2" × 1/2" PEX F1960 HPP Tee (EX16665) 1" × 1" × 1/2" PEX F1960 HPP Tee (EX16885)

Tubing
3/4" - PureLink Plus (White, Red, Blue) 1" - PureLink Plus (White, Red, Blue) 1 1/4" - PureLink Plus (White, Red, Blue) 1 1/2" - PureLink Plus (White, Red, Blue)
2" - PureLink Plus (White, Red, Blue)

% PEX pipe and fittings are intended for use in multi-purpose piping systems of
  residential occupancies as defined in ANSI/NFPA 13D, "Installation of Sprinkler Systems
  in One- and Two- Family Dwellings and Manufactured Homes", the National Building Code of
  Canada, and the International Residential Code, Section 2904, and are designed to
  withstand a working pressure of not less than 130 psi at 120° F. PEX pipe and fittings
  are intended to be installed in accordance with the requirements specified in the
  manufacturer’s installation instructions and ANSI/NFPA 13D. Protection is intended to be
  provided for PEX pipe and fittings in multi-purpose piping systems. The minimum
  protection should consist of either (1) one layer of 3/8-in. gypsum wallboard, (2) a
  suspended membrane ceiling with lay-in panels or tiles having a weight of not less than
  0.35 lbs per sq ft when installed with metallic support grids, or (3) 1/2 in plywood.
  PEX pipe and fittings are intended for use in areas where the maximum ambient
  temperature does not exceed 120° F. These pipe and fittings are not intended to be
  installed in outdoor applications. The PEX pipe and fittings are intended for use in
  wet-pipe systems only and have not been evaluated for use in dry-pipe systems.
** Pipe and fittings Certified as a system using installation and design manual titled 
   "SureLink™ Fire Safety System".
¢  Product is authorized to bear the cNSF and/or the cNSFus Mark.

* These products may also be represented by the trade name SureLink™.

Facility : P4 Canada

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing^ § **

PEX

PureLink Plus

ASTM E84
1/2", 3/4"

^ Flame Spread Index <= 25, Smoke Developed Index <= 50
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing^ § **

PEX

SureLink

ASTM E84
1/2", 3/4"

^ Flame Spread Index <= 25, Smoke Developed Index <= 50
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].


Fire Sprinkler Pipe and Fitting Systems

Product Type Material Type Trade Name Product Standard

Pipe and Fitting System% ** ¢

MLTPL

PureLink Plus *

ANSI/CAN/UL 1821

Adapter
3/4" PEX F1960 × 3/4" M/Sweat No Lead Brass Adapter (EX27122NL) 1" PEX F1960 × 1" M/Sweat No Lead Brass Adapter (EX27128NL) 1-1/4" PEX F1960 × 1-1/4" M/Sweat No Lead Brass Adapter (EX27135NL) 1-1/2" PEX F1960 × 1-1/2" M/Sweat No Lead Brass Adapter (EX27141NL)
2" PEX F1960 × 2" M/Sweat No Lead Brass Adapter (EX27154NL) 3/4" PEX F1960 × 3/4" F/Sweat No Lead Brass Adapter (EX27222NL) 1" PEX F1960 × 1" F/Sweat No Lead Brass Adapter (EX27228NL) 1-1/4" PEX F1960 × 1-1/4" F/Sweat No Lead Brass Adapter (EX27235NL)
1-1/2" PEX F1960 × 1-1/2" F/Sweat No Lead Brass Adapter (EX27241NL) 2" PEX F1960 × 2" F/Sweat No Lead Brass Adapter (EX27254NL) 3/4" PEX F1960 × 3/4" MNPT No Lead Brass Adapter (EX27522NL) 1" PEX F1960 × 1" MNPT No Lead Brass Adapter (EX27528NL)
1-1/4" PEX F1960 × 1-1/4" MNPT No Lead Brass Adapter (EX27535NL) N/A1-1/2" PEX F1960 × 1-1/2" MNPT No Lead Brass Adapter (EX27541NL) 2" PEX F1960 × 2" MNPT No Lead Brass Adapter (EX27554NL) 3/4" PEX F1960 × 3/4" FNPT No Lead Brass Adapter (EX27622NL)
1" PEX F1960 × 1" FNPT No Lead Brass Adapter (EX27628NL) 1-1/4" PEX F1960 × 1-1/4" FNPT No Lead Brass Adapter (EX27635NL) 1-1/2" PEX F1960 × 1-1/2" FNPT No Lead Brass Adapter (EX27641NL) 3/4" PEX F1960 × 1/2" M/Sweat No Lead Brass Adapter (EX27125NL)
N/A3/4" PEX F1960 × 1/2" F/Sweat No Lead Brass Adapter (EX27225NL) 3/4" PEX F1960 × 1/2" MNPT No Lead Brass Adapter (EX27525NL)

Coupling
3/4" × 3/4" PEX F1960 HPP Coupling (EX19022) 1" × 1" PEX F1960 HPP Coupling (EX19028) 1-1/4" × 1-1/4" PEX F1960 HPP Coupling (EX19035) 1-1/2" × 1-1/2" PEX F1960 HPP Coupling (EX19041)
2" × 2" PEX F1960 HPP Coupling (EX19054) 1-1/4" × 1" PEX F1960 HPP Coupling (EX19238) 1-1/2" × 1-1/4" PEX F1960 HPP Coupling (EX19243) 1-1/2" × 1" PEX F1960 HPP Coupling (EX19248)
2" × 1-1/2" PEX F1960 HPP Coupling (EX19264) 1" × 3/4" PEX F1960 HPP Coupling (EX19282) 3/4" × 1/2" PEX F1960 HPP Coupling (EX19225)

Elbow
3/4" × 3/4" PEX F1960 HPP Elbow EX18022 1" × 1" PEX F1960 HPP Elbow EX18028 1-1/4" × 1-1/4" PEX F1960 HPP Elbow EX18035 1-1/2" × 1-1/2" PEX F1960 HPP Elbow EX18041
2" × 2" PEX F1960 HPP Elbow EX18054

Expansion Rings
3/4" PEX F1960 HPP Expansion Ring 1" PEX F1960 HPP Expansion Ring 1-1/4" PEX F1960 HPP Expansion Ring 1-1/2" PEX F1960 HPP Expansion Ring
2" PEX F1960 HPP Expansion Ring

Plugs
3/4" PEX F1960 HPP Plug (EX15022) 1" PEX F1960 HPP Plug (EX15028) 1-1/4" PEX F1960 HPP Plug (EX15035) 1-1/2" PEX F1960 HPP Plug (EX15041)
2" PEX F1960 HPP Plug (EX15054)

Tees
3/4" × 3/4" × 3/4" PEX F1960 HPP Tee (EX16222) 1-1/4" × 1-1/4" × 3/4" PEX F1960 HPP Tee (EX16332) 1-1/4" × 1-1/4" × 1-1/4" PEX F1960 HPP Tee (EX16333) 1-1/4" × 1-1/4" × 1" PEX F1960 HPP Tee (EX16338)
1-1/4" × 1" × 3/4" PEX F1960 HPP Tee (EX16382) N1-1/4" × 1" × 1" PEX F1960 HPP Tee (EX16388) 1-1/2" × 1-1/4" × 3/4" PEX F1960 HPP Tee (EX16432) 1-1/2" × 1-1/4" × 1-1/4" PEX F1960 HPP Tee (EX16433)
1-1/2" × 1-1/4" × 1" PEX F1960 HPP Tee (EX16438) 1-1/2" × 1-1/2" × 3/4" PEX F1960 HPP Tee (EX16442) 1-1/2" × 1-1/2" × 1-1/4" PEX F1960 HPP Tee (EX16443) 1-1/2" × 1-1/2" × 1-1/2" PEX F1960 HPP Tee (EX16444)
1-1/2" × 1-1/2" × 1" PEX F1960 HPP Tee (EX16448) 1-1/2" × 1" × 1" PEX F1960 HPP Tee (EX16488) 2" × 1-1/2" × 3/4" PEX F1960 HPP Tee (EX16642) 2" × 1-1/2" × 1-1/4" PEX F1960 HPP Tee (EX16643)
2" × 1-1/2" × 1-1/2" PEX F1960 HPP Tee (EX16644) 2" × 1-1/2" × 1" PEX F1960 HPP Tee (EX16648) 2" × 2" × 3/4" PEX F1960 HPP Tee (EX16662) 2" × 2" × 1-1/4" PEX F1960 HPP Tee (EX16663)
2" × 2" × 1-1/2" PEX F1960 HPP Tee (EX16664) 2" × 2" × 2" PEX F1960 HPP Tee (EX16666) 2" × 2" × 1" PEX F1960 HPP Tee (EX16668) 1" × 3/4" × 3/4" PEX F1960 HPP Tee (EX16822)
1" × 3/4" × 1" PEX F1960 HPP Tee (EX16828) 1" × 1" × 3/4" PEX F1960 HPP Tee (EX16882) 1" × 1" × 1" PEX F1960 HPP Tee (EX16888) 3/4" × 3/4" × 1/2" PEX F1960 HPP Tee (EX16225)
3/4" × 1/2" × 3/4" PEX F1960 HPP Tee (EX16252) 3/4" × 1/2" × 1/2" PEX F1960 HPP Tee (EX16255) 1-1/4" × 1-1/4" × 1/2" PEX F1960 HPP Tee (EX16335) 1-1/2" × 1-1/2" × 1/2" PEX F1960 HPP Tee (EX16445)
1/2" × 1/2" × 3/4" PEX F1960 HPP Tee (EX16552) 2" × 2" × 1/2" PEX F1960 HPP Tee (EX16665) 1" × 1" × 1/2" PEX F1960 HPP Tee (EX16885)

Tubing
3/4" - PureLink Plus (White, Red, Blue) 1" - PureLink Plus (White, Red, Blue) 1 1/4" - PureLink Plus (White, Red, Blue) 1 1/2" - PureLink Plus (White, Red, Blue)
2" - PureLink Plus (White, Red, Blue)

% PEX pipe and fittings are intended for use in multi-purpose piping systems of
  residential occupancies as defined in ANSI/NFPA 13D, "Installation of Sprinkler Systems
  in One- and Two- Family Dwellings and Manufactured Homes", the National Building Code of
  Canada, and the International Residential Code, Section 2904, and are designed to
  withstand a working pressure of not less than 130 psi at 120° F. PEX pipe and fittings
  are intended to be installed in accordance with the requirements specified in the
  manufacturer’s installation instructions and ANSI/NFPA 13D. Protection is intended to be
  provided for PEX pipe and fittings in multi-purpose piping systems. The minimum
  protection should consist of either (1) one layer of 3/8-in. gypsum wallboard, (2) a
  suspended membrane ceiling with lay-in panels or tiles having a weight of not less than
  0.35 lbs per sq ft when installed with metallic support grids, or (3) 1/2 in plywood.
  PEX pipe and fittings are intended for use in areas where the maximum ambient
  temperature does not exceed 120° F. These pipe and fittings are not intended to be
  installed in outdoor applications. The PEX pipe and fittings are intended for use in
  wet-pipe systems only and have not been evaluated for use in dry-pipe systems.
** Pipe and fittings Certified as a system using installation and design manual titled 
   "SureLink™ Fire Safety System".
¢  Product is authorized to bear the cNSF and/or the cNSFus Mark.

* These products may also be represented by the trade name SureLink™.


 
Huaru Pipe Inc 
116 Maple Street
Commerce, TX 75428 
United States 
315-418-0770

Facility : Commerce, TX

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing[1] [2]

PEX

Valtec

CAN/ULC S102.2
1/2" - 1"

[1] Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].
[2] Flame Spread Value (FSV) <= 25
    Smoke Developed Value (SDV) <= 50

Tubing[4]

PEX

Valtec

ASTM E84
1/2" - 1"

[4] The Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
    between tubing runs.
    Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing[2]

PEX

Valtec

CAN/ULC S102.2
1/2"-1"

[2] Flame Spread Value (FSV) <= 25
    Smoke Developed Value (SDV) <= 50

Tubing[3] [6]

PEX

Valtec

ASTM E84
1/2"-1"

[3] Flame Spread Index <= 25
    Smoke Developed Index <=50
[6] When insulated with MICRO-LOK® 
    fiberglass insulation as per the the pipe manufacturer's installation instructions,
    tubing shall be marked [cNSF®-fs ASTM E84 FS = 25 / SD = 50]



 
Hydro Master Supply Inc. 
3381 Lawson Boulevard
New York, NY 11572 
United States 
516-870-3812
Visit this company's website

Facility : # 1 China

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing# $ * [1] [2]

PEX

HydroMaster

ASTM E84
3/8", 1/2" - 2"

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[2] ASTM E84, 1/2" - 2" The Flame Spread Index and Smoke Developed Index for 1/2" - 2"
    tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi
    performance fiberglass insulation as per RIFENG installation instructions. The 3/8"
    tubing is not insulated.

Tubing$ & [1] [3]

PEX

HydroMaster

CAN/ULC S102.2
3/8", 1/2" - 2"

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation), Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[3] 3/8" Tubing (without insulation)
    Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
    1/2" through 2" Tubing (with insulation)
    Flame Spread Rating and Smoke Developed Classification based on when the tubing is field
    insulated with
    JM Microlok HP Hi Performance
    Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing
    shall be marked
    [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[4] [5]

PEX

HydroMaster

ASTM E84
3/8" - 2"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] Certified for red and white PEX 5106 monowall pipe.
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2"
    JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation
    instructions. Flame
    Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between
    tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing[4] [6]

PEX

HydroMaster

CAN/ULC S102.2
3/8" - 2"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] Certified for red and white PEX 5106 monowall pipe.
[6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with
    1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's
    installation
    instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[7] [8]

PEX

HydroMaster

ASTM E84
3/8" - 1"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[7] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[8] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2"
    JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation
    instructions (all listed
    construction/color/size combinations greater than or equal to 3/8" in diameter). Flame
    Spread Index and
    Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing
    shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing[7] [9]

PEX

HydroMaster

CAN/ULC S102.2
3/8" - 1"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[7] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[9] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with
    1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's
    installation
    instructions (all listed construction/color/size combinations greater than or equal to
    3/8" in
    diameter). Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].



 
IPEX Incorporated 
3 Place Du Commerce, Suite 101
Île-Des-Soeurs 
Verdun, QC H3E 1H7 
Canada 
514-769-2200
Visit this company's website

Facility : Mississauga, Ontario, Canada

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Fittings~ [1] [2] [3]

PVC

System XFR

CAN/ULC S102.2
101002 ELBOW 180° FOR 526431 101004 ELBOW 180° FOR 526441 101009 ELBOW 180° FOR 526505 101011 ELBOW 180° FOR 526443
101012 ELBOW 180° FOR 526444 101013 ELBOW 180° FOR 526432 101014 ELBOW 180° FOR 526442 101015 ELBOW 180° FOR 526433
101016 ELBOW 180° FOR 526434 101018 ELBOW 90° FOR 526431 101019 ELBOW 90° FOR 526432 101020 ELBOW 90° FOR 526433
101021 ELBOW 90° FOR 526434 101023 ELBOW 90° FOR 526443 101024 ELBOW 90° FOR 526444 101031 PVC DWV MAIN PIECE FOR 526321
101032 PVC DWV MAIN PIECE FOR 526329 101034 PVC DWV MAIN PIECE FOR 526555 101035 PVC DWV MAIN PIECE FOR 526556 101037 PVC DWV MAIN PIECE FOR 526586
101039 PVC DWV RING FOR 526586 & 526588 101041 PVC DWV MAIN PIECE FOR 526330 101045 PVC DWV MAIN PIECE FOR 526485 101046 PVC DWV MAIN PIECE FOR 526486
101047 PVC DWV MAIN PIECE FOR 526487 101048 PVC DWV MAIN PIECE FOR 526494 101066 PVC DWV NUT 1½" 101068 PVC DWV NUT 2"
101104 PVC DWV MAIN PIECE FOR 526104 101105 PVC DWV MAIN PIECE FOR 526105 101134 PVC DWV MAIN PIECE FOR 526040 101135 PVC DWV MAIN PIECE FOR 526041
101136 PVC DWV MAIN PIECE FOR 526103 101161 PVC DWV MAIN PIECE FOR 526161 101401 PVC DWV 1 1/2" PLUG MPT 101402 PVC DWV 2" PLUG MPT
101403 PVC DWV 3" PLUG MPT 101404 PVC DWV 4" PLUG MPT 101405 PVC DWV 6" PLUG MPT 101588 PVC DWV MAIN PIECE FOR 526588
101601 PVC DWV 1 1/2" CLEANOUT SPXFPT 101602 PVC DWV 2" CLEANOUT SPXFPT 101603 PVC DWV 3" CLEANOUT SPXFPT 101604 PVC DWV 4" CLEANOUT SPXFPT
101606 PVC DWV 6" CLEANOUT SPXFPT 101630 NUT 1¼" 101631 NUT 1½" 101890 THREAD CAP FOR P-TRAP
526003 P-TRAP PRIMER TEE 3" X 3" X ½" HXHXFPT 526011 P-TRAP PRIMER TEE 4" X 4" X ½" HXHXFPT 526025 PVC DWV 3" 90° SHORT ELBOW HXH 526035 PVC DWV 2" 90° SHORT ELBOW HXH
526040 PVC DWV 1 1/2" CLEANOUT TEE W/P PVC 526041 PVC DWV 2" CLEANOUT TEE W/P PVC 526042 PVC DWV 1 1/2" CLEANOUT W/O PLUG 526046 PVC DWV 2" CLEANOUT W/O PLUG
526047 PVC DWV 3" CLEANOUT W/O PLUG 526056 PVC DWV 2" X 2" X 1 1/2" TY HXHXH 526058 PVC DWV 2" X 1 1/2" X 1 1/2" TY HXHXH 526060 PVC DWV 3" X 3" X 2" TY HXHXH
526061 PVC DWV 3" X 3" X 1 1/2" TY HXHXH 526064 PVC DWV 4" X 4" X 2" TY HXHXH 526066 PVC DWV 4" X 4" X 3" TY HXHXH 526071 PVC DWV 2" 45° ELBOW HXS
526072 PVC DWV 4" 45° HXS 526081 PVC DWV 1 1/2" TY HXHXH 526082 PVC DWV 2" TY HXHXH 526083 PVC DWV 3" TY HXHXH
526084 PVC DWV 4" TY HXHXH 526103 PVC DWV 3" CLEANOUT TEE W/P PVC 526104 PVC DWV 4" CLEANOUT TEE W/P PVC 526105 PVC DWV 4" X 3" X 4" CLEANOUT T W/P PVC
526121 PVC DWV 1 1/2" 90° DEG ELBOW HXH 526122 PVC DWV 2" 90°ELBOW HXH 526123 PVC DWV 3" 90° ELBOW HXH 526124 PVC DWV 4" 90°ELBOW HXH
526161 PVC DWV 6" CLEANOUT TEE W/P PVC 526171 PVC DWV 1 1/2" 45° Y HXHXH 526172 PVC DWV 2" 45° Y HXHXH 526173 PVC DWV 3" 45° Y HXHXH
526174 PVC DWV 4" 45° Y HXHXH 526175 PVC DWV 6" Y HXHXH 526194 PVC DWV 2" X 1 1/2" X 1 1/2" Y HXHXH 526195 PVC DWV 2" X 2" X 1 1/2" Y HXHXH
526196 PVC DWV 3" X 3" X 2" Y HXHXH 526197 PVC DWV 4" X 4" X 3" Y HXHXH 526198 PVC DWV 4" X 4" X 2" Y HXHXH 526199 PVC DWV 6" X 6" X 4" Y HXHXH
526201 PVC DWV 3" X 3" X 1 1/2" Y HXHXH 526221 PVC DWV 1 1/2" 45° ELBOW HXS 526223 PVC DWV 3" 45° ELBOW HXS 526231 PVC DWV 1 1/2" 90° ELBOW HXS
526232 PVC DWV 2" 90° ELBOW HXS 526233 PVC DWV 3" 90° ELBOW HXS 526234 PVC DWV 4" 90° ELBOW SPxH 526241 PVCDWV 1 1/2" 45° ELBOW HXH
526242 PVC DWV 2" 45° ELBOW HXH 526243 PVC DWV 3" 45° ELBOW HXH 526244 PVC DWV 4" 45° ELBOW HXH 526251 PVC DWV 1 1/2" 22.5° ELBOW HxH
526252 PVC DWV 2" 22.5° ELBOW HxH 526253 PVC DWV 3" 22.5° ELBOW HxH 526254 PVC DWV 4" 22.5° ELBOW HxH 526261 PVC DWV 1 1/2" 60° ELBOW HxH
526262 PVC DWV 2" 60° ELBOW HxH 526263 PVC DWV 3" 60° ELBOW HxH 526264 PVC DWV 4" 60° ELBOW HXH 526277 PVC DWV 1 1/2" X 1/2" DISH.ADAPT.
526282 PVC DWV 2" x 1/2" RED. BUSHING SXH 526284 PVC DWV 3" X 2" REDUC. BUSH. SPxH 526286 PVC DWV 4" X 3" REDUC. BUSH. SPxH 526288 PVC DWV 4" X 2" REDUC. BUSH. SPxH
526291 PVC/DWV 1 1/2" TUBE END C/O W/P PVC 526292 PVC DWV 3" x 1 1/2" REDUC. BUSH. SPxH 526294 PVC DWV 4" X 3" REDUC. BUSH. SPxH 526277 PVC DWV 1 1/2"x1/2" XFR Red. Bushing SpxFPT
526278 PVC DWV1 1/2"x 3/4" XFR Red. Bushing SpxFPT 526298 PVC/DWV 2" TUBE END C/O W/P PVC 526299 PVC/DWV 3" TUBE END C/O W/P PVC 526300 PVC/DWV 4" TUBE END C/O W/P PVC
526310 PVC DWV 2" AD.SEWER TO DWV SPXH 526311 PVC DWV 3"AD.SEWER to DWV SPXH 526312 PVC DWV 4" AD.SEWER to DWV SPXH 526313 PVC DWV 6" ADAPT SEWER TO DWV HXS
526321 PVC DWV 1 1/2" TRAP ADAP. H 526329 PVC DWV 1 1/2" X 1 1/4" TRAP ADAP. H 526330 1 1/2" 90° ELBOW W/SLIP JOINT NUT 526331 PVC DWV 1 1/2" ADAPTER HxMPT
526332 PVC DWV 2" ADAPTER HxMPT 526333 PVC DWV 3" ADAPTER HxMPT 526334 PVC DWV 4" ADAPTER HxMPT 526341 PVC DWV 1 1/2" ADAPTER HxFPT
526342 PVC DWV 2" ADAPTER HxFPT 526343 PVC DWV 3" ADAPTER HxFPT 526344 PVC DWV 4" ADAPTER HxFPT 526345 PVC DWV 1 1/2" CLEANOUT W/PLUG PVC
526346 PVC DWV 2" CLEANOUT W/PLUG PVC 526347 PVC DWV 3" CLEANOUT W/PLUG PVC 526348 PVC DWV 4" CLEANOUT W/PLUG PVC 526349 PVC DWV 6" CLEANOUT W/PLUG PVC
526351 PVC DWV 1 1/2" COUPLING HXH 526352 PVC DWV 2" COUPLING HXH 526353 PVC DWV 3" COUPLING HXH 526354 PVC DWV 4" COUPLING HXH
526362 PVC DWV 2" X 1 1/2" COUPLING HXH 526363 PVC DWV 3" X 1 1/2" COUPLING HXH 526364 PVC DWV 3" X 2" COUPLING HXH 526365 PVC DWV 4" X 2" COUPLING HXH
526366 PVC DWV 4" X 3" COUPLING HXH 526369 PVC DWV 4" X 1 1/2" COUPLING HXH 526376 PVC DWV 4" X 3" COUPLING HXH 526395 PVC DWV 3" X 1 1/2" INLET LEFT HAND (90DEG)
526022 PVC DWV 3X1.5 INLET LEFT HAND (45DEG) 526396 PVC DWV 3" X 2" INLET LEFT HAND 526397 PVC DWV 3" X 1 1/2" INLET RIGHT HAND (90DEG) 526021 PVC DWV 3X1.5 INLET RIGHT HAND (45DEG)
526398 PVC DWV 3" X 2" INLET RIGHT HAND 526018 PVC DWV 3X1.5 DOUBLE INLET 526402 PVC DWV 2" GASKET PLUG 526404 PVC DWV 4" GASKET PLUG
526405 PVC DWV 6" GASKET PLUG 526411 PVC DWV 1 1/2" PERMANENT CAP 526412 PVC DWV 2" PERMANENT CAP 526413 PVC DWV 3" PERMANENT CAP
526414 PVC DWV 4" PERMANENT CAP 526431 PVC DWV 1 1/2" P-TRAP 526432 PVC DWV 2" P-TRAP 526433 PVC DWV 3" P-TRAP
526434 PVC DWV 4" P-TRAP 526441 PVC DWV 1 1/2" P-TRAP W/PLUG 526442 PVC DWV 2" P-TRAP W/PLUG 526443 PVC DWV 1 1/2" P-TRAP DOUBLE SEAL
526444 PVC DWV 2" P-TRAP DOUBLE SEAL 526485 PVC DWV 1½" EXPANSION JOINT HXH 526486 PVC DWV 2" EXPANSION JOINT HXH 526487 PVC DWV 3" EXPANSION JOINT HXH
526494 PVC DWV 3" EXPANSION JOINT HXS 526028 4" PVC DWV Expansion Joints 526495 DISHWASHER Y 1½" HXHXBARBS 526496 PVC DWV DISHWASHER WYE 1 1/2"x1 1/2"x3/4" HxHxHOSEBARB
526499 PVC DWV ELBOW 4" 180° HXH 526505 PVC DWV 1 1/2" P-TRAP DOUBLE SEAL W/P 526522 PVC DWV 2" CAST IRON ADAPT MJ 526523 PVC DWV 3" CAST IRON ADAPT MJ
526524 PVC DWV 4" CAST IRON ADAPT MJ 526535 PVC DWV 4" X 3" CAST IRON ADAPT MJ 526538 PVC DWV 3" X 1 1/2" DOUBLE TY HXHXHXH 526542 PVC DWV 1 1/2" DOUBLE TY HXHXHXH
526543 PVC DWV 2" DOUBLE TY HXHXHXH 526547 PVC DWV 2" X 1 1/2" DOUBLE TY HXHXHXH 526550 PVC DWV 1 1/2" TY SXHXH 526552 PVC DWV 3" X 3" X 1 1/2" TY SXHXH
526555 PVC DWV 1 1/2" TRAP ADAPT. M 526556 PVC DWV 1 1/2" X 1 1/4" TRAP ADAPT. M 526573 PVC DWV 4" CLOSET FLANGE H 526019 PVC DWV 4"x3" OFFSET CLOSET FLANGE
526584 PVC DWV 4" X 3" CLOSET FLANGE H 526586 PVC DWV 4" X 3" CLOSET FLANGE ADJUST. 526588 PVC DWV 4" X 3" CLO FLANGE ADJ W/C H 526591 PVC DWV 4" X 3" CLOSET FLANGE W/CAP
526592 PVC DWV 4" X 3" CLOSET FLANGE SP 526637 PVC DWV 1 1/2" DOUBLE Y HXHXHXH 526639 PVC DWV 3" DOUBLE Y HXHXHXH 526642 PVC DWV 2" X 1 1/2" DOUBLE Y HXHXHXH
526643 PVC DWV 3" X 1 1/2" DOUBLE Y HXHXHXH 526644 PVC DWV 3" X 2" DOUBLE Y HXHXHXH 526860 PVC DWV 6" X 4" RED. COUPLING HXH 526199 6" x 6" x 4" 45° WYE (HxHxH)
526175 6" x 6" x 6" 45° WYE (HxHxH) 526606 8" x 8" x 4" 45° WYE (HxHxH) 526607 8" x 8" x 6" 45° WYE (HxHxH) 526560 8" x 8" x 8" 45° WYE (HxHxH)
526054 6" x 4" Bushing SpxH 526073 6" x 6" 45° Elbow SpxH 526125 6" x 6" 90° Elbow HxH 526126 8" x 8" 90° Elbow HxH
526175 6" × 6" × 6" 45° Wye HxHxH 526199 6" × 6" × 4" 45° Wye HxHxH 526226 8" x 8" 45° Elbow SpxH 526242 2" x 2" 45° Elbow HxH
526235 6" x 6" 90° Elbow SpxH 526245 6" x 6" 45° Elbow HxH 526246 8" x 8" 45° Elbow HxH 526255 6" x 6" 22 1/2° Elbow HxH
526356 6" x 6" Coupling With Pipe Stop (HxH) 526358 8" x 8" Coupling With Pipe Stop (HxH) 526377 6" × 6" × 6" TY HxHxH 526385 6" × 6" × 4" TY HxHxH
526415 6” Cap H 526416 8” Cap H 526446 8" x 4" Bushing (SpxH) 526447 8" x 6" Bushing (SpxH)
526550 2” TY SpigotxHxH 526560 8" x 8" x 8" 45° Wye HxHxH 526606 8" x 8" x 4" 45° Wye HxHxH 526607 8" x 8" x 6" 45° Wye HxHxH
Coupling Socket x Socket 526183 10" PVC DWV COUPLING HxH Coupling Socket x Socket 526184 12" PVC DWV COUPLING HxH SYSTEM Elbow 22.5° 526156 8"x22 1/2D PVC DWV ELBOW HxH Elbow 45° Socket x Socket 526421 10"x45D PVC DWV ELBOW HxH
Elbow 45° Socket x Socket 526422 12"x45D PVC DWV SHORT TURN ELBOW HxH Elbow 45° Spigot x Socket 526531 10"x45D PVC DWV SHORT TURN ELBOW SPxH Elbow 45° Spigot x Socket 526532 12"x45D PVC DWV SHORT TURN ELBOW SPxH Elbow 90° Socket X socket 526132 10"x90D PVC DWV ELBOW HxH
Elbow 90° Socket X socket 526133 12"x90D PVC DWV ELBOW HxH Elbow 90°Spigot X Socket 526114 10"x90D PVC DWV ELBOW SPxH Elbow 90° Spigot X Socket 526115 12"x90D PVC DWV ELBOW SPxH Plug 526350 8" PVC DWV C/O W/ PLUG SPxGSKT PLUG
Plug 526357 8" PVC DWV PLUG C/O MPT Plug 526355 8" PVC DWV FTG C/O SPxFPT Reducer Bushing Spigot x Socket 526851 10"x4" PVC DWV FLUSH RED. BUSHING SPxH Reducer Bushing Spigot x Socket 526852 10"x6" PVC DWV FLUSH RED. BUSHING SPxH
Reducer Bushing Spigot x Socket 526853 10"x8" PVC DWV FLUSH RED. BUSHING SPxH Reducer Bushing Spigot x Socket 526854 12"x4" PVC DWV FLUSH RED. BUSHING SPxH Reducer Bushing Spigot x Socket 526855 12"x6" PVC DWV FLUSH RED. BUSHING SPxH Reducer Bushing Spigot x Socket 526856 12"x8" PVC DWV FLUSH RED. BUSHING SPxH
Reducer Bushing Spigot x Socket 526857 12"x10" PVC DWV FLUSH RED. BUSHING SPxH Reducer Bushing Spigot x Socket 526843 10"x8"x45D PVC DWV WYE HxHxH Reducer Coupling Socket x Socket 526208 8"x4" PVC DWV REDUCER COUPLING HxH Reducer Coupling Socket x Socket 526209 8"x6" PVC DWV REDUCER COUPLING HxH
Reducer Coupling Socket x Socket 526212 10"x8" PVC DWV REDUCER COUPLING HxH Reducer Coupling Socket x Socket 526215 12"x10" PVC DWV REDUCER COUPLING HxH Wye 45° Socket x Socket x Socket 526840 10"x45D PVC DWV WYE HxHxH Wye 45° Socket x Socket x Socket 526841 10"x4"x45D PVC DWV WYE HxHxH
Wye 45° Socket x Socket x Socket 526842 10"x6"x45D PVC DWV WYE HxHxH Wye 45° Socket x Socket x Socket 526844 12"x45D PVC DWV WYE HxHxH Wye 45° Socket x Socket x Socket 526845 12"x4"x45D PVC DWV WYE HxHxH Wye 45° Socket x Socket x Socket 526846 12"x6"x45D PVC DWV WYE HxHxH
Wye 45° Socket x Socket x Socket 526847 12"x8"x45D PVC DWV WYE HxHxH Wye 45° Socket x Socket x Socket 526848 12"x10"x45D PVC DWV WYE HxHxH XFR PVC Fabricated Fittings – 45° Wye 8” x 4” XFR PVC Fabricated Fittings – 45° Wye 8” x 6”
XFR PVC Fabricated Fittings – 45° Wye 8” x 8” XFR PVC Fabricated Fittings – 45° Wye 10” x 4” XFR PVC Fabricated Fittings – 45° Wye 10” x 6” XFR PVC Fabricated Fittings – 45° Wye 10” x 8”
XFR PVC Fabricated Fittings – 45° Wye 10” x 10” XFR PVC Fabricated Fittings – 45° Wye 12” x 4” XFR PVC Fabricated Fittings – 45° Wye 12” x 6” XFR PVC Fabricated Fittings – 45° Wye 12” x 8”
XFR PVC Fabricated Fittings – 45° Wye 12” x 10” XFR PVC Fabricated Fittings – 45° Wye 12” x 12” XFR PVC Fabricated Fittings – 45° Wye 14” x 4” XFR PVC Fabricated Fittings – 45° Wye 14” x 6”
XFR PVC Fabricated Fittings – 45° Wye 14” x 8” XFR PVC Fabricated Fittings – 45° Wye 14” x 10” XFR PVC Fabricated Fittings – 45° Wye 14” x 12” XFR PVC Fabricated Fittings – 45° Wye 14” x 14”
XFR PVC Fabricated Fittings – 45° Wye 16” x 4” XFR PVC Fabricated Fittings – 45° Wye 16” x 6” XFR PVC Fabricated Fittings – 45° Wye 16” x 8” XFR PVC Fabricated Fittings – 45° Wye 16” x 10”
XFR PVC Fabricated Fittings – 45° Wye 16” x 12” XFR PVC Fabricated Fittings – 45° Wye 16” x 14” XFR PVC Fabricated Fittings – 45° Wye 16” x 16” XFR PVC Fabricated Fittings – 45° Wye 18” x 4”
XFR PVC Fabricated Fittings – 45° Wye 18” x 6” XFR PVC Fabricated Fittings – 45° Wye 18” x 8” XFR PVC Fabricated Fittings – 45° Wye 18” x 10” XFR PVC Fabricated Fittings – 45° Wye 18” x 12”
XFR PVC Fabricated Fittings – 45° Wye 18” x 14” XFR PVC Fabricated Fittings – 45° Wye 18” x 16” XFR PVC Fabricated Fittings – 45° Wye 18” x 18” XFR PVC Fabricated Fittings – Apartment Fitting 3”x3”x3”x1½”x1½” - 526007
XFR PVC Fabricated Fittings – Cap 8” XFR PVC Fabricated Fittings – Cap 10” XFR PVC Fabricated Fittings – Cap 12” XFR PVC Fabricated Fittings – Cap 14”
XFR PVC Fabricated Fittings – Coupling 8” XFR PVC Fabricated Fittings – Coupling 10” XFR PVC Fabricated Fittings – Coupling 12” XFR PVC Fabricated Fittings – Coupling 14”
XFR PVC Fabricated Fittings – Coupling 16” XFR PVC Fabricated Fittings – Coupling 18” XFR PVC Fabricated Fittings – Coupling ¼” Bend / 90° Elbow 8” XFR PVC Fabricated Fittings – Coupling ¼” Bend / 90° Elbow 10”
XFR PVC Fabricated Fittings – Coupling ¼” Bend / 90° Elbow 12” XFR PVC Fabricated Fittings – Coupling ¼” Bend / 90° Elbow 14” XFR PVC Fabricated Fittings – Coupling ¼” Bend / 90° Elbow 16” XFR PVC Fabricated Fittings – Coupling ¼” Bend / 90° Elbow 18”
XFR PVC Fabricated Fittings – Coupling 1/8” Bend / 45° Elbow 8” XFR PVC Fabricated Fittings – Coupling 1/8” Bend / 45° Elbow 10” XFR PVC Fabricated Fittings – Coupling 1/8” Bend / 45° Elbow 12” XFR PVC Fabricated Fittings – Coupling 1/8” Bend / 45° Elbow 14”
XFR PVC Fabricated Fittings – Coupling 1/8” Bend / 45° Elbow 16” XFR PVC Fabricated Fittings – Coupling 1/8” Bend / 45° Elbow 18” XFR PVC Fabricated Fittings – Coupling 1/16” Bend / 22 ½° Elbow 8” XFR PVC Fabricated Fittings – Coupling 1/16” Bend / 22 ½° Elbow 10”
XFR PVC Fabricated Fittings – Coupling 1/16” Bend / 22 ½° Elbow 12” XFR PVC Fabricated Fittings – Coupling 1/16” Bend / 22 ½° Elbow 14” XFR PVC Fabricated Fittings – Coupling 1/16” Bend / 22 ½° Elbow 18” XFR PVC Fabricated Fittings – Coupling 1/16” Bend / 22 ½° Elbow 18”
XFR PVC Fabricated Fittings–Double Apartment Fitting 3x3x3x3x1½x1½x1½x1½-526008 XFR PVC Fabricated Fittings – Double Wye 8” x 4” XFR PVC Fabricated Fittings – Double Wye 8” x 6” XFR PVC Fabricated Fittings – Double Wye 8” x 8”
XFR PVC Fabricated Fittings – Double Wye 10” x 4” XFR PVC Fabricated Fittings – Double Wye 10” x 6” XFR PVC Fabricated Fittings – Double Wye 10” x 8” XFR PVC Fabricated Fittings – Double Wye 10” x 10”
XFR PVC Fabricated Fittings – Double Wye 12” x 4” XFR PVC Fabricated Fittings – Double Wye 12” x 6” XFR PVC Fabricated Fittings – Double Wye 12” x 8” XFR PVC Fabricated Fittings – Double Wye 12” x 10”
XFR PVC Fabricated Fittings – Double Wye 12” x 12” XFR PVC Fabricated Fittings – Double Wye 14” x 4” XFR PVC Fabricated Fittings – Double Wye 14” x 6” XFR PVC Fabricated Fittings – Double Wye 14” x 8”
XFR PVC Fabricated Fittings – Double Wye 14” x 10” XFR PVC Fabricated Fittings – Double Wye 14” x 12” XFR PVC Fabricated Fittings – Double Wye 14” x 14” XFR PVC Fabricated Fittings – Double Wye 16” x 4”
XFR PVC Fabricated Fittings – Double Wye 16” x 6” XFR PVC Fabricated Fittings – Double Wye 16” x 8” XFR PVC Fabricated Fittings – Double Wye 16” x 10” XFR PVC Fabricated Fittings – Double Wye 16” x 12”
XFR PVC Fabricated Fittings – Double Wye 16” x 14” XFR PVC Fabricated Fittings – Double Wye 16” x 16” XFR PVC Fabricated Fittings – Double Wye 18” x 4” XFR PVC Fabricated Fittings – Double Wye 18” x 6”
XFR PVC Fabricated Fittings - Double ° Wye 18” x 8” XFR PVC Fabricated Fittings – Double Wye 18” x 10” XFR PVC Fabricated Fittings – Double Wye 18” x 12” XFR PVC Fabricated Fittings – Double Wye 18” x 14”
XFR PVC Fabricated Fittings – Double Wye 18” x 16” XFR PVC Fabricated Fittings – Double Wye 18” x 18” XFR PVC Fabricated Fittings – Reducing Bushing 8” x 4” XFR PVC Fabricated Fittings – Reducing Bushing 8” x 6”
XFR PVC Fabricated Fittings – Reducing Bushing 10” x 4” XFR PVC Fabricated Fittings – Reducing Bushing 10” x 6” XFR PVC Fabricated Fittings – Reducing Bushing 10” x 8” XFR PVC Fabricated Fittings – Reducing Bushing 12” x 4”
XFR PVC Fabricated Fittings – Reducing Bushing 12” x 6” XFR PVC Fabricated Fittings – Reducing Bushing 12” x 8” XFR PVC Fabricated Fittings – Reducing Bushing 12” x 10” XFR PVC Fabricated Fittings – Reducing Bushing 14” x 4”
XFR PVC Fabricated Fittings – Reducing Bushing 14” x 6” XFR PVC Fabricated Fittings – Reducing Bushing 14” x 8” XFR PVC Fabricated Fittings – Reducing Bushing 14” x 10” XFR PVC Fabricated Fittings – Reducing Bushing 14” x 12”
XFR PVC Fabricated Fittings – Reducing Bushing 16” x 4” XFR PVC Fabricated Fittings – Reducing Bushing 16” x 6” XFR PVC Fabricated Fittings – Reducing Bushing 16” x 8” XFR PVC Fabricated Fittings – Reducing Bushing 16” x 10”
XFR PVC Fabricated Fittings – Reducing Bushing 16” x 12” XFR PVC Fabricated Fittings – Reducing Bushing 16” x 14” XFR PVC Fabricated Fittings – Reducing Bushing 18” x 4” XFR PVC Fabricated Fittings – Reducing Bushing 18” x 6”
XFR PVC Fabricated Fittings – Reducing Bushing 18” x 8” XFR PVC Fabricated Fittings – Reducing Bushing 18” x 10” XFR PVC Fabricated Fittings – Reducing Bushing 18” x 12” XFR PVC Fabricated Fittings – Reducing Bushing 18” x 14”
XFR PVC Fabricated Fittings – Reducing Bushing 18” x 16” XFR PVC Fabricated Fittings – Tee 8” x 4” XFR PVC Fabricated Fittings – Tee 8” x 6” XFR PVC Fabricated Fittings – Tee 8” x 8”
XFR PVC Fabricated Fittings – Tee 10” x 4” XFR PVC Fabricated Fittings – Tee 10” x 6” XFR PVC Fabricated Fittings – Tee 10” x 8” XFR PVC Fabricated Fittings – Tee 10” x 10”
XFR PVC Fabricated Fittings – Tee 12” x 4” XFR PVC Fabricated Fittings – Tee 12” x 6” XFR PVC Fabricated Fittings – Tee 12” x 8” XFR PVC Fabricated Fittings – Tee 12” x 10”
XFR PVC Fabricated Fittings – Tee 12” x 12” XFR PVC Fabricated Fittings – Tee 14” x 4” XFR PVC Fabricated Fittings – Tee 14” x 6” XFR PVC Fabricated Fittings – Tee 14” x 8”
XFR PVC Fabricated Fittings – Tee 14” x 10” XFR PVC Fabricated Fittings – Tee 14” x 12” XFR PVC Fabricated Fittings – Tee 14” x 14” XFR PVC Fabricated Fittings – Tee 16” x 4”
XFR PVC Fabricated Fittings – Tee 16” x 6” XFR PVC Fabricated Fittings – Tee 16” x 8” XFR PVC Fabricated Fittings – Tee 16” x 10” XFR PVC Fabricated Fittings – Tee 16” x 12”
XFR PVC Fabricated Fittings – Tee 16” x 14” XFR PVC Fabricated Fittings – Tee 16” x 16” XFR PVC Fabricated Fittings – Tee 18” x 4” XFR PVC Fabricated Fittings – Tee 18” x 6”
XFR PVC Fabricated Fittings – Tee 18” x 8” XFR PVC Fabricated Fittings – Tee 18” x 10” XFR PVC Fabricated Fittings – Tee 18” x 12” XFR PVC Fabricated Fittings – Tee 18” x 14”
XFR PVC Fabricated Fittings – Tee 18” x 16” XFR PVC Fabricated Fittings – Tee 18” x 18” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 8” x 4” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 8” x 6”
XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 8” x 8” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 10” x 4” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 10” x 6” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 10” x 8”
XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 10” x 10” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 12” x 4” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 12” x 6” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 12” x 8”
XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 12” x 10” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 12” x 12” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 14” x 4” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 14” x 6”
XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 14” x 8” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 14” x 10” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 14” x 12” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 14” x 14”
XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 16” x 4” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 16” x 6” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 16” x 8” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 16” x 10”
XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 16” x 12” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 16” x 14” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 16” x 16” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 18” x 4”
XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 18” x 6” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 18” x 8” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 18” x 10” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 18” x 12”
XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 18” x 14” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 18” x 16” XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 18” x 18”

~ Product is authorized to bear the cNSF Mark.
[1] System XFR® PVC fittings have been tested in conjunction with System XFR® pipe only, for
    use in drain, waste and ventilation applications.
[2] FSR and SDC listed values obtained with 10 mm and 0 mm exposed pipe lengths between
    fittings.
[3] Flame Spread Value (FSV) <=25
    Smoke Developed Value (SDV) <=50

Pipe~ [1] [2] [3]

PVC

System XFR

CAN/ULC S102.2
1 1/2" Sch 40
2" Sch 40
3" Sch 40
4" Sch 40
6" Sch 40
8" Sch 40
10" Sch 40
12" Sch 40
14" Sch 40
16" Sch 40
18" Sch 40

~ Product is authorized to bear the cNSF Mark.
[1] System XFR® PVC fittings have been tested in conjunction with System XFR® pipe only, for
    use in drain, waste and ventilation applications.
[2] FSR and SDC listed values obtained with 10 mm and 0 mm exposed pipe lengths between
    fittings.
[3] Flame Spread Value (FSV) <=25
    Smoke Developed Value (SDV) <=50

NOTE: Only products bearing the NSF Mark are NSF Certified.

Facility : Toronto, Ontario, Canada

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Fittings~ [1] [2] [3]

CPVC

IPEX (Aquarise)

CAN/ULC S102.2

Adapter (IPS S x CTS S)
359101 3/4" 359100 1/2"

Adapter (IPS SOC x CTS S)
359098 3/4" 359097 1/2"

45° Elbow (Soc x Soc)
359164 1/2" 359165 3/4" 359166 1" 359167 1 1/4"
359168 1 1/2" 359169 2" 359170 2 1/2" 359171 3"
359172 4" 359173 6"

90° Elbow (Soc x Soc)
359194 1/2" 359195 3/4" 359196 1" 359197 1 1/4
359198 1 1/2" 359199 2" 359200 2 1/2" 359201 3"
359202 4" 359203 6"

90° Street Elbow (S x S)
359175 1/2" 359176 3/4" 359177 1"

Cap (Soc)
359109 1/2" 359110 3/4" 359111 1" 359112 1 1/4"
359113 1 1/2" 359114 2" 359115 2 1/2" 359116 3"
359107 4" 359108 6"

Female Adapter, SOC x FPT
359800 1/2" 359801 3/4" 359803 1 1/4" 359804 1 1/2"
359805 2"

Female Adapter, SP x FPT
359820 1/2" 359821 3/4" 359822 1"

Flange x Socket
359228 1/2" 359229 3/4" 359230 1" 359231 1 1/4"
359232 1 1/2" 359233 2" 359040 2 1/2" 359234 2 1/2"
359041 3" 359235 3" 359043 4" 359236 4"
359042 6" 359238 6"

Coupling (Soc x Soc)
359132 1/2" 359133 3/4" 359134 1" 359135 1 1/4"
359136 1 1/2" 359137 2" 359138 2 1/2" 359139 3"
359140 4" 359141 6"

Male Adapter, SOC x MPT
359811 1/2" 359812 3/4" 359813 1" 359814 1 1/4"
359815 1 1/2" 359816 2"

Male Adapter, SP x MPT
359823 1/2" 359824 3/4" 359825 1"

Manifold Tee (¾" SPGx¾" SOC w/One ½" SOC Branches)
359061 3/4" x 1/2"

Manifold Tee (¾" SPGx¾" SOC w/Two ½" SOC Branches)
359060 3/4" x 1/2"

Reducer Bushing (Sp x Soc)
359375 3/4" x 1/2" 359376 1" x 1/2" 359377 1" x 3/4" 359378 1 1/4" x 1/2"
359379 1 1/4" x 3/4" 359380 1 1/4" x 1" 359381 1 1/2" x 1/2" 359382 1 1/2" x 3/4"
359383 1 1/2" x 1" 359384 1 1/2" x 1 1/4" 359385 2" x 1/2" 359386 2" x 3/4"
359387 2" x 1" 359388 2" x 1 1/4" 359389 2" x 1 1/2" 359390 2 1/2" x 3/4"
359391 2 1/2" x 1" 359392 2 1/2" x 2" 359393 3" x 1 1/2" 359394 3" x 2"
359395 3" x 2 1/2" 359428 4" x 1 1 /4" 359429 4" x 1 1/2" 359396 4" x 2"
359430 4" x 2 1/2" 359397 4" x 3" 359398 6" x 2" 359399 6" x 3"
359400 6" x 4"

Reducer Coupling (Soc x Soc)
359460 3/4" x 1/2" 359461 1" x 1/2" 359462 1" x 3/4" 359463 1 1/4" x 1"
359465 1 1/2" x 1" 359466 1 1/2" x 1 1/4" 359467 2" x 1" 359458 2" x 1 1/2"
359470 3" x 2" 359459 4" x 2" 359472 4" x 3" 359510 6" x 6" x 2"
359511 6" x 6" x 3" 359512 6" x 6" x 4"

Reducing Tee (S x S x S)
359513 3/4" x 1/2" x 3/4" 359514 3/4" x 1/2" x 1/2" 359492 3/4" x 3/4" x 1/2" 359493 1" x 1" x 1/2"
359494 1" x 1" x 3/4" 359495 1 1/4" x 1 1/4" x 1" 359515 1 1/2" x 1 1/2" x 1/2" 359496 1 1/2" x 1 1/2" x 3/4"
359497 1 1/2" x 1 1/2" x 1" 359498 2" x 2" x 1/2" 359499 2" x 2" x 3/4" 359500 2" x 2" x 1"
359501 2" x 2" x 1 1/2" 359503 2 1/2" x 2 1/2" x 1/2" 359504 2 1/2" x 2 1/2" x 3/4" 359505 2 1/2" x 2 1/2" x 1"
359506 2 1/2" x 2 1/2" x 1 1/4" 359507 2 1/2" x 2 1/2" x 2" 359502 3" x 3" x 2" 359508 4" x 4" x 2"
359509 4" x 4" x 3"

Tee (Soc x Soc x Soc)
359481 1/2" 359482 3/4" 359483 1" 359484 1 1/4"
359485 1 1/2" 359486 2" 359487 2 1/2" 359488 3"
359489 4" 359490 6"

Union (S x S)
359520 1/2" 359521 3/4" 359522 1" 359523 1 1/4"
359524 1 1/2" 359525 2" 359051 3" 359550 4"

Van Stone Style Flange 150 lbs.
359268 3" 359266 1 1/2" 359267 2" 359270 4"

~ Product is authorized to bear the cNSF Mark.
[1] AquaRise pipe and fittings are certified as a system to CAN/ULC S102.2.
[2] Flame Spread Value (FSV) <=25
    Smoke Developed Value (SDV) <=50
[3] Product may be marked with the "IPEX" trade name only.

Pipe~ [1] [2] [3]

CPVC 4120

IPEX (Aquarise)

CAN/ULC S102.2
1/2" - 6" SDR 11
1 1/2" - 6" SDR 21

~ Product is authorized to bear the cNSF Mark.
[1] AquaRise pipe and fittings are certified as a system to CAN/ULC S102.2.
[2] Flame Spread Value (FSV) <=25
    Smoke Developed Value (SDV) <=50
[3] Product may be marked with the "IPEX" trade name only.

Fitting Compounds[2]

CPVC 4120

AquaRise

CAN/ULC S102.2
Nominal 2.7 to 20 mm thick

[2] Flame Spread Value (FSV) <=25
    Smoke Developed Value (SDV) <=50

Pipe Compound[2]

CPVC 4120

AquaRise

CAN/ULC S102.2
Nominal 1.9 to 17 mm thick

[2] Flame Spread Value (FSV) <=25
    Smoke Developed Value (SDV) <=50

NOTE: Only products bearing the NSF Mark are NSF Certified.


 
IPEX USA LLC 
3 Place Du Commerce, Suite 101
Verdun, QC H3E 1H7 
Canada 
514-769-2200
Visit this company's website

Facility : Kingman, AZ

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Pipe~ [1] [2]

PVC

Xirtec PVC

CAN/ULC S102.2
1/2" - 6" Sch 40

~ Product is authorized to bear the cNSF Mark.
[1] Approved for a thickness of 3 mm - 14mm.
[2] Flame Spread Value (FSV) =10         
    Smoke Developed Value (SDV) =195
    


Facility : Ft. Pierce, FL

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Pipe~ [1] [2]

PVC

IPEX

CAN/ULC S102.2
1/2" - 12" Sch 40
1/2" - 8" Sch 80

~ Product is authorized to bear the cNSF Mark. 
[1] Approved for a thickness of 3 mm - 14mm. 
[2] Flame Spread Value (FSV) =10
    Smoke Developed Value (SDV) =195

Pipe~ [1] [2]

PVC

Xirtec PVC

CAN/ULC S102.2
1/2" - 12" Sch 40
1/2" - 8" Sch 80

~ Product is authorized to bear the cNSF Mark. 
[1] Approved for a thickness of 3 mm - 14mm. 
[2] Flame Spread Value (FSV) =10
    Smoke Developed Value (SDV) =195

Pipe~ [1] [2]

PVC

Silver-Line

CAN/ULC S102.2
1/2" - 12" Sch 40
1/2" - 8" Sch 80

~ Product is authorized to bear the cNSF Mark. 
[1] Approved for a thickness of 3 mm - 14mm. 
[2] Flame Spread Value (FSV) =10
    Smoke Developed Value (SDV) =195


Facility : Asheville, NC

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Pipe~ [1] [2]

PVC

IPEX

CAN/ULC S102.2
1/2" - 12" Sch 40
1/2" - 8" Sch 80

~ Product is authorized to bear the cNSF Mark. 
[1] Approved for a thickness of 3 mm - 14mm. 
[2] Flame Spread Value (FSV) =10
    Smoke Developed Value (SDV) =195

Pipe~ [1] [2]

PVC

Xirtec PVC

CAN/ULC S102.2
1/2" - 12" Sch 40
1/2" - 8" Sch 80

~ Product is authorized to bear the cNSF Mark. 
[1] Approved for a thickness of 3 mm - 14mm. 
[2] Flame Spread Value (FSV) =10
    Smoke Developed Value (SDV) =195

Pipe~ [1] [2]

PVC

RadonX

CAN/ULC S102.2
4" Sch 40

~ Product is authorized to bear the cNSF Mark. 
[1] Approved for a thickness of 3 mm - 14mm. 
[2] Flame Spread Value (FSV) =10
    Smoke Developed Value (SDV) =195

Pipe~ [1] [2]

PVC

Silver-Line

CAN/ULC S102.2
1/2" - 12" Sch 40
1/2" - 8" Sch 80

~ Product is authorized to bear the cNSF Mark. 
[1] Approved for a thickness of 3 mm - 14mm. 
[2] Flame Spread Value (FSV) =10
    Smoke Developed Value (SDV) =195


Facility : Pineville, NC

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Fittings~ [1] [2]

CPVC

System 636

CAN/ULC S102.2

45 Elbow H x H
2" 3" 4" 6"
8" 10" 12"

45 Elbow SP x H
4"

45 Wye H x H x H
6" x 6" x 4" 8" x 8" x 4" 10" x 10" x 4" 12" x 12" x 4"

45 Wye H x H x H x H
6" x 6" x 4"

90 Elbow SP x H
4"

90 Elbows HxH
2" 2" Long 3" 3" Long
4" 4" Long 6" 6" Long
8" 8" Long 10" 12"

Coupling H x SP
2" 3" 4"

Coupling SP x SP
2" 3" 4"

Couplings H x H
1 1/2" 2" 2 1/2" 3"
4" 6" 8" 10"
12"

End Caps
6" 8" 10" 12"

Female Adapter
2"

Plug MPT
1/2"

Reducer Bushing SP x Barb
1 1/2" x 1 1/2"

Reducer Bushing SP x FPT
2" x 1/2"

Reducer Bushings SP x H
1 1/2" x 1/2" 2" x 1/2" 2" x 3/4'' 2" x 1 1/2"
3" x 2'' 3" x 2'' Hex 3" x 2 1/2" 4" x 2"
6" x 4" 8" x 6"

Reducer Couplings H x H
3" x 2'' 4" x 3" 4" x 6"

Tees H x H x 1/2" NPT
1 1/2" 2" 3" 4"

Tees H x H x H
2" 3" 3" x 2" 3" x 3" x 2"
4" 4" x 2" 4" x 4" x 2" 6"
6" x 6" x 4" 6" x 6" x 6" 8" 8" x 8" x 6"

Custom Assemblies
Bosch 6" x Metric Adapter Bosch 8" x Metric Adapter CPVC 3" Tee CPVC 4" Tee
CPVC Reducer bushing 8" x 6" Lochinvar – 2" Flue Connector Lochinvar – 3" Flue Connector Lochinvar - Appliance Adaptor 2", 3", 4"
Viessmann - 2" Adapter Coupling Viessmann - 3" Adapter Coupling Viessmann - 4" Adapter Coupling

~ Product is authorized to bear the cNSF Mark.
[1] System 636 pipe and fittings are certified as a system to CAN/ULC S102.2.
[2] Flame Spread Value (FSV) <=25
    Smoke Developed Value (SDV) <=50

Pipe~ [1] [2]

CPVC

System 636

CAN/ULC S102.2
1 1/2" 2" 2 1/2" 3"
4" 6" 8" 10"
12"

~ Product is authorized to bear the cNSF Mark.
[1] System 636 pipe and fittings are certified as a system to CAN/ULC S102.2.
[2] Flame Spread Value (FSV) <=25
    Smoke Developed Value (SDV) <=50


Facility : Lawton, OK

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Pipe~ [1] [2]

PVC

IPEX

CAN/ULC S102.2
1/2" - 12" Sch 40
1/2" - 8" Sch 80

~ Product is authorized to bear the cNSF Mark. 
[1] Approved for a thickness of 3 mm - 14mm. 
[2] Flame Spread Value (FSV) =10
    Smoke Developed Value (SDV) =195

Pipe~ [1] [2]

PVC

Xirtec PVC

CAN/ULC S102.2
1/2" - 12" Sch 40
1/2" - 8" Sch 80

~ Product is authorized to bear the cNSF Mark. 
[1] Approved for a thickness of 3 mm - 14mm. 
[2] Flame Spread Value (FSV) =10
    Smoke Developed Value (SDV) =195

Pipe~ [1] [2]

PVC

Silver-Line

CAN/ULC S102.2
1/2" - 12" Sch 40
1/2" - 8" Sch 80

~ Product is authorized to bear the cNSF Mark. 
[1] Approved for a thickness of 3 mm - 14mm. 
[2] Flame Spread Value (FSV) =10
    Smoke Developed Value (SDV) =195



 
J-M Manufacturing Co., Inc. DBA JM Eagle 
9 Peach Tree Hill Road
Livingston, NJ 07039 
United States 
310-693-8200
Visit this company's website

Facility : # 1 Adel, GA

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe* +  ^

PE 4710

JM Eagle

FM 1613
IPS 4" - 24" (PC 335) DR 7
IPS 4" - 24" (PC 250) DR 9
IPS 4" - 24" (PC 200) DR 11
DIOD 4" - 24" (PC 335) DR 7
DIOD 4" - 24" (PC 250) DR 9
DIOD 4" - 24" (PC 200) DR 11

* Products comply with requirements of NFPA 24 Standard for the Installation of Private
  Fire Service Mains and Their Appurtenances.
  
+  Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73F.
   
^  This product may be marked with an alternate trade name: JM Eagle, [JM Eagle Logo],
   and/or [JMM Logo].
   


Facility : # 4 Columbia, MO

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe# + [G]

PVCO

J-M Manufacturing

UL 1285
PC 235: 6", 8", 10", 12"
PC 305: 6", 8"

# This product may be marked with an alternate trade name:  J-M Manufacturing, PW Eagle,
  [JMM Logo] or [JM Eagle Logo].
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

NOTE: Only products bearing the NSF Mark are Certified.

Facility : # 6 Fontana, CA

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe# + [G]

PVCO

J-M Manufacturing

UL 1285
PC 305: 6", 8", 10", 12", 14", 16", 18", 20", 24"
PC 235: 6", 8", 10", 12", 14", 16", 18", 20", 24"

# This product may be marked with an alternate trade name: J-M Manufacturing, PW Eagle,
  [JMM Logo] or [JM Eagle Logo].
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


Facility : # 7 Hastings, NE

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe^ *  +

PE 4710

JM Eagle

FM 1613
IPS 4" - 24" (PC 335) DR 7
IPS 4" - 24" (PC 250) DR 9
IPS 4" - 24" (PC 200) DR 11
DIOD 4" - 24" (PC 335) DR 7
DIOD 4" - 24" (PC 250) DR 9
DIOD 4" - 24" (PC 200) DR 11

^ This product may be marked with an alternate trade name: JM Eagle, [JM Eagle Logo],
  and/or [JMM Logo].
  
*  Products comply with requirements of NFPA 24 Standard for the Installation of Private
   Fire Service Mains and Their Appurtenances.
   
+  Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73F.
   


Facility : # 8 Kingman, AZ

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe^ *  +

PE 4710

JM Eagle

FM 1613
IPS 4" - 24" (PC 335) DR 7
IPS 4" - 24" (PC 250) DR 9
IPS 4" - 24" (PC 200) DR 11
DIOD 4" - 24" (PC 335) DR 7
DIOD 4" - 24" (PC 250) DR 9
DIOD 4" - 24" (PC 200) DR 11

^ This product may be marked with an alternate trade name: JM Eagle, [JM Eagle Logo],
  and/or [JMM Logo].
  
*  Products comply with requirements of NFPA 24 Standard for the Installation of Private
   Fire Service Mains and Their Appurtenances.
   
+  Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73F.
   


Facility : # 9 Magnolia, AR

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe* + ^

PE 4710

J-M Manufacturing

FM 1613
PC 335: IPS 4" - 12" DR 7
PC 250: IPS 4" - 12" DR 9
PC 200: IPS 4" - 12" DR 11
PC 335: DIOD 4" - 12" DR 7
PC 250: DIOD 4" - 12" DR 9
PC 200: DIOD 4" - 12" DR 11

* Products comply with requirements of NFPA 24 Standard for the Installation of Private
  Fire Service Mains and Their Appurtenances.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
^ This product may be marked with an alternate trade name:  JM Eagle, [JM Eagle Logo]
  and/or [JMM Logo].


Facility : # 11 Cochranton, PA

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe* +  ^

PE 4710

JM Eagle

FM 1613
IPS 4" - 24" (PC 335) DR 7
IPS 4" - 24" (PC 250) DR 9
IPS 4" - 24" (PC 200) DR 11
DIOD 4" - 24" (PC 335) DR 7
DIOD 4" - 24" (PC 250) DR 9
DIOD 4" - 24" (PC 200) DR 11

* Products comply with requirements of NFPA 24 Standard for the Installation of Private
  Fire Service Mains and Their Appurtenances.
  
+  Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73F.
   
^  This product may be marked with an alternate trade name: JM Eagle, [JM Eagle Logo],
   and/or [JMM Logo].
   


Facility : # 15 Sunnyside, WA

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe^ *  +

PE 4710

JM Eagle

FM 1613
IPS 4" - 24" (PC 335) DR 7
IPS 4" - 24" (PC 250) DR 9
IPS 4" - 24" (PC 200) DR 11
DIOD 4" - 24" (PC 335) DR 7
DIOD 4" - 24" (PC 250) DR 9
DIOD 4" - 24" (PC 200) DR 11

^ This product may be marked with an alternate trade name: JM Eagle, [JM Eagle Logo],
  and/or [JMM Logo].
  
*  Products comply with requirements of NFPA 24 Standard for the Installation of Private
   Fire Service Mains and Their Appurtenances.
   
+  Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73F.
   


Facility : # 17 Tulsa, OK

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe* + ^

PE 4710

J-M Manufacturing

FM 1613
PC 335: IPS 4" - 24" DR 7
PC 250: IPS 4" - 24" DR 9
PC 200: IPS 4" - 24" DR 11
PC 335: DIOD 4" - 24" DR 7
PC 250: DIOD 4" - 24" DR 9
PC 200: DIOD 4" - 24" DR 11

* Products comply with requirements of NFPA 24 Standard for the Installation of Private
  Fire Service Mains and Their Appurtenances.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
^ This product may be marked with an alternate trade name:  JM Eagle, [JM Eagle Logo]
  and/or [JMM Logo].


Facility : # 19 Wharton, TX

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe# + [G]

PVCO

J-M Manufacturing

UL 1285
PC 165: 16"
PC 235: 6", 8", 10", 12"
PC 305: 6", 8"

# This product may be marked with an alternate trade name:  J-M Manufacturing, PW Eagle,
  [JMM Logo] or [JM Eagle Logo].
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

NOTE: Only products bearing the NSF Mark are Certified.


 
Jasmine Trading Co., Ltd. 
Room 4008-2, Building A, Vanke Financial Center
No. 55, Jihua 5th Road Chanchen 
District,Foshan,Guangdong, 528000 
China 
18520999200

Facility : # 1 China

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing# $ * [2] [10]

PEX

HTM/ARTMEEN

ASTM E84
3/8", 1/2" - 2"

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[10] ASTM E84, 1/2" - 2" The Flame Spread Index and Smoke Developed Index for 1/2" - 2"
     tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi
     performance fiberglass insulation as per RIFENG installation instructions. The 3/8"
     tubing is not insulated.

Tubing$ & [2] [11]

PEX

HTM/ARTMEEN

CAN/ULC S102.2
3/8", 1/2" - 2"

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[11] 3/8" Tubing (without insulation)
     Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
     1/2" through 2" Tubing (with insulation)
     Flame Spread Rating and Smoke Developed Classification based on when the tubing is field
     insulated with JM Microlok HP Hi Performance
     Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing
     shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[1] [3]

PEX

HTM/ARTMEEN

ASTM E84
3/8" - 2"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[1] Certified for red and white PEX 5106 monowall pipe for Potable water application.
    Certified for red and white PEX 5006 for Radiant Heat Flooring application.
[3] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].

Tubing[1] [4]

PEX

HTM/ARTMEEN

CAN/ULC S102.2
3/8" - 2"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[1] Certified for red and white PEX 5106 monowall pipe for Potable water application.
    Certified for red and white PEX 5006 for Radiant Heat Flooring application.
[4] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].

Tubing[5] [6]

PEX

HTM/ARTMEEN

ASTM E84
3/8" - 1"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] Certified for blue,red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe for Potable water application. Certified for blue,red and white PPEX 5006 2-layer
    skinned and 4-layer barrier for Radiant Heat Flooring application.
[6] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance   fiberglass insulation as per RIFENG
    installation instructions (all listed construction/color/size combinations greater than
    or equal to 3/8" in diameter). Flame Spread Index and Smoke Developed Index based on
    minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM
    E84 FS<=25/SD<=50].

Tubing[5] [7]

PEX

HTM/ARTMEEN

CAN/ULC S102.2
3/8" - 1"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] Certified for blue,red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe for Potable water application. Certified for blue,red and white PPEX 5006 2-layer
    skinned and 4-layer barrier for Radiant Heat Flooring application.
[7] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions (all listed construction/color/size
    combinations greater than or equal to 3/8" in diameter). Tubing shall be Marked
    [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[3] [8]

PEX

HTM/ARTMEEN PEXa

ASTM E84
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[3] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[8] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.           
    Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[4] [8]

PEX

HTM/ARTMEEN PEXa

CAN/ULC S102.2
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[8] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.           
    Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[3] [9]

PEX

HTM/ARTMEEN PEXa

ASTM E84
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[3] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[9] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  
    Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
    Certified for red,  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
    sizes only.

Tubing[4] [9]

PEX

HTM/ARTMEEN PEXa

CAN/ULC S102.2
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[9] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  
    Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
    Certified for red,  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
    sizes only.



 
John L Schultz Ltd. 
1723 55é Avenue
Dorval, QC H9P 2W3 
Canada 
800-363-6240

Facility : Guangdong, China

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing# $ * [1] [2]

PEX

aqua-dynamic

ASTM E84
3/8", 1/2" - 2"

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] ASTM E84, 1/2'' - 2'' The Flame Spread Index and Smoke Developed Index for 1/2"-2"
    tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi
    performance fiberglass insulation as per RIFENG installation instructions. The 3/8"
    tubing is not insulated.
[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50

Tubing$ & [2] [3]

PEX

aqua-dynamic

CAN/ULC S102.2
3/8", 1/2" - 2"

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[3] 3/8" Tubing (without insulation)
    Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
    1/2" through 2" Tubing (with insulation)
    Flame Spread Rating and Smoke Developed Classification based on when the tubing is field
    insulated with JM Microlok HP Hi Performance
    Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing
    shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[4] [5]

PEX

aqua-dynamic

ASTM E84
3/8" - 2"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] Certified for red and white PEX 5106 monowall pipe.
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].

Tubing[4] [6]

PEX

aqua-dynamic

CAN/ULC S102.2
3/8" - 2"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] Certified for red and white PEX 5106 monowall pipe.
[6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].

Tubing[7] [8]

PEX

aqua-dynamic

ASTM E84
3/8" - 1"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[7] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[8] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance	fiberglass insulation as per RIFENG
    installation instructions (all listed construction/color/size combinations greater than
    or equal to 3/8" in diameter). Flame Spread Index and Smoke Developed Index based on
    minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM
    E84 FS<=25/SD<=50].

Tubing[7] [9]

PEX

aqua-dynamic

CAN/ULC S102.2
3/8" - 1"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[7] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[9] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions (all listed construction/color/size
    combinations greater than or equal to 3/8" in diameter). Tubing shall be Marked
    [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[5] [10]

PEX

aqua-dynamic PEX-A

ASTM E84
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[10] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.		
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[6] [10]

PEX

aqua-dynamic PEX-A

CAN/ULC S102.2
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[10] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.		
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[5] [11]

PEX

aqua-dynamic PEX-A

ASTM E84
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[11] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
     Certified for red,  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
     sizes only.  

Tubing[6] [11]

PEX

aqua-dynamic PEX-A

CAN/ULC S102.2
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[11] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
     Certified for red,  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
     sizes only.  



 
Mexichem Colombia SAS 
Autopista Sur No. 71-75
Bogota 
Colombia 
57 1 782 5000

Facility : Bogota, Colombia

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing* ^

CPVC

Tuberia Presion HotPro CPVC

ASTM E84
1/2" - 1-1/4"

* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
^ Flame Spread Index <= 25, Smoke Developed Index <= 50



 
MrPEX Systems (a division of Safelink Systems, Inc.) 
14799 Jackal Street NW
Suite 100 
Ramsey, MN 55303 
United States 
800-716-3406 
952-440-7704

Facility : Ulricehamn, Sweden

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing§ ** [1]

PEX

Mr. PEX (3-layer and 4-layer Tubing)

ASTM E84

1/2", 5/8", 3/4"

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50



 
National Pipe & Plastics, Inc. 
One North Page Avenue
Endicott, NY 13760 
United States 
800-836-4350 
607-729-9381
Visit this company's website

Facility : Endicott, NY

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe

PVC

Dura-Blue

UL 1285
PC 305 4",6",8", 10", 12", 14", 16", 18", 20", 24" DR 14
PC 235 4",6",8", 10", 12", 14", 16", 18", 20", 24" DR 18
PC 200 14", 16", 18", 20", 24" DR 21
PC 165 4",6",8", 10", 12", 14", 16", 18", 20", 24" DR 25
PC 125 14", 16", 18", 20", 24" DR 32.5

Pipe

PVC

National

FM 1612
PC 250: 4", 6", 8", 10", 12" DR 14
PC 185: 4", 6", 8", 10", 12" DR 18


Facility : Colfax, NC

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe

PVC

Dura-Blue

UL 1285
PC305 4",6", 8", 10", 12", 14", 16", 18", 20", 24" DR 14
PC235 4",6", 8", 10", 12", 14", 16", 18", 20", 24" DR 18
PC200 14", 16", 18", 20", 24" DR 21
PC165 4",6", 8", 10", 12", 14", 16", 18", 20", 24" DR 25
PC125 14", 16", 18", 20", 24" DR 32.5

Pipe

PVC

National

FM 1612
PC 250: 4", 6", 8", 10", 12" DR 14
PC 185: 4", 6", 8", 10", 12" DR 18



 
Northern Pipe Products 
1302 39th Street NW
Fargo, ND 58102-2808 
United States 
701-282-7655

Facility : Fargo, ND

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe+ ¢ [G]

PVC

Northern Pipe Products

UL 1285
4" - 12" DR 14
4" - 24" DR 18
14" - 24" DR 21
4" - 24" DR 25

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.



 
ONE WORLD SUPPLY INC 
9451 Langelier
Montreal, QC H1P 0A1 
Canada 
514-378-0049
Visit this company's website

Facility : # 1 China

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing# $ * [1] [2]

PEX

XPAND

ASTM E84
3/8", 1/2" - 2"

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
    
[2] ASTM E84, 1/2" - 2" The Flame Spread Index and Smoke Developed Index for 1/2" - 2"
    tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi
    performance fiberglass insulation as per RIFENG installation instructions. The 3/8"
    tubing is not insulated.

Tubing$ & [1] [3]

PEX

XPAND

CAN/ULC S102.2
3/8", 1/2" - 2"

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation), Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
    
[3] 3/8" Tubing (without insulation) Tubing shall be marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
    1/2" through 2" Tubing (with insulation) Flame Spread Rating and Smoke Developed
    Classification based on when the tubing is field insulated with JM Microlok HP Hi
    Performance Fiberglass insulation as per the pipe manufacturer's installation
    instructions. Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[4] [5]

PEX

XPAND

ASTM E84
3/8" - 2"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
    
[4] Certified for red and white PEX 5106 monowall pipe.
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].

Tubing[4] [6]

PEX

XPAND

CAN/ULC S102.2
3/8" - 2"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
    
[4] Certified for red and white PEX 5106 monowall pipe.
[6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].

Tubing[7] [8]

PEX

XPAND

ASTM E84
3/8" - 1"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
    
[7] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[8] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance   fiberglass insulation as per RIFENG
    installation instructions (all listed construction/color/size combinations greater than
    or equal to 3/8" in diameter). Flame Spread Index and Smoke Developed Index based on
    minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM
    E84 FS<=25/SD<=50].
    

Tubing[7] [8]

PEX

XPAND

CAN/ULC S102.2
3/8" - 1"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
    
[7] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[8] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance   fiberglass insulation as per RIFENG
    installation instructions (all listed construction/color/size combinations greater than
    or equal to 3/8" in diameter). Flame Spread Index and Smoke Developed Index based on
    minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM
    E84 FS<=25/SD<=50].
    

Tubing[5] [9]

PEX

XPAND PEXa

ASTM E84
1/8" - 3"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
    
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[9] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.           
    Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[4] [9]

PEX

XPAND PEXa

CAN/ULC S102.2
1/8" - 3"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
    
[4] Certified for red and white PEX 5106 monowall pipe.
[9] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.           
    Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[3] [10]

PEX

XPAND PEXa

ASTM E84
1/8" - 3"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
    
[3] 3/8" Tubing (without insulation) Tubing shall be marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
    1/2" through 2" Tubing (with insulation) Flame Spread Rating and Smoke Developed
    Classification based on when the tubing is field insulated with JM Microlok HP Hi
    Performance Fiberglass insulation as per the pipe manufacturer's installation
    instructions. Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
[10] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
     Certified for red, white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
     sizes only. 

Tubing[6] [10]

PEX

XPAND PEXa

CAN/ULC S102.2
1/8" - 3"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
    
[6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[10] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
     Certified for red, white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
     sizes only. 



 
Pipeline Plastics, LLC 
1301 Solana Boulevard
Suite 1440 
Westlake, TX 76262 
United States 
940-627-9100
Visit this company's website

Facility : Rupert , ID

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe* +

PE 4710

Pipeline Plastics

FM 1613
IPS 2" - 24" DR 7 (PC 335)
IPS 2" - 24" DR 9 (PC 250)
IPS 2" - 36" DR 11 (PC 200)
DIPS 2" - 24" DR 7 (PC 335)
DIPS 2" - 24" DR 9 (PC 250)
DIPS 2" - 36" DR 11 (PC 200)

* Products comply with requirements of NFPA 24 Standard for the Installation of Private
  Fire Service Mains and Their Appurtenances.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.


Facility : Fair Bluff, NC

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe* +

PE 4710

Pipeline Plastics

FM 1613
IPS 2" - 24" DR 7 (PC 335)
IPS 2" - 24" DR 9 (PC 250)
IPS 2" - 36" DR 11 (PC 200)
DIPS 2" - 24" DR 7 (PC 335)
DIPS 2" - 24" DR 9 (PC 250)
DIPS 2" - 36" DR 11 (PC 200)

* Products comply with requirements of NFPA 24 Standard for the Installation of Private
  Fire Service Mains and Their Appurtenances.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.


Facility : Belle Fourche, SD

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe* +

PE 4710

Pipeline Plastics

FM 1613
IPS 2" - 24" DR 7 (PC 335)
IPS 2" - 24" DR 9 (PC 250)
IPS 2" - 36" DR 11 (PC 200)
DIPS 2" - 24" DR 7 (PC 335)
DIPS 2" - 24" DR 9 (PC 250)
DIPS 2" - 36" DR 11 (PC 200)

* Products comply with requirements of NFPA 24 Standard for the Installation of Private
  Fire Service Mains and Their Appurtenances.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.


Facility : Decatur, TX

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe* +

PE 4710

Pipeline Plastics

FM 1613
IPS 2" - 24" DR 7 (PC 335)
IPS 2" - 24" DR 9 (PC 250)
IPS 2" - 36" DR 11 (PC 200)
DIPS 2" - 24" DR 7 (PC 335)
DIPS 2" - 24" DR 9 (PC 250)
DIPS 2" - 36" DR 11 (PC 200)

* Products comply with requirements of NFPA 24 Standard for the Installation of Private
  Fire Service Mains and Their Appurtenances.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.


Facility : Levelland, TX

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe* +

PE 4710

Pipeline Plastics

FM 1613
IPS 2" - 24" DR 7 (PC 335)
IPS 2" - 24" DR 9 (PC 250)
IPS 2" - 36" DR 11 (PC 200)
DIPS 2" - 24" DR 7 (PC 335)
DIPS 2" - 24" DR 9 (PC 250)
DIPS 2" - 36" DR 11 (PC 200)

* Products comply with requirements of NFPA 24 Standard for the Installation of Private
  Fire Service Mains and Their Appurtenances.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.



 
PPI America Inc. 
1440 Renaissance Drive
Suite 430 
Park Ridge, IL 60068 
United States 
847-430-4477
Visit this company's website

Facility : # 1 Korea

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Fittings#

MLTPL

iPVC fitting

UL 1285
PC 235: 4", 6", 8"
PC 305: 4", 6", 8"

# Certified for PC 235 & PC 305 for the following configurations:
  
  iPVC Fitting
  Coupling(Socket) - 6", & 8"
  Repair Coupling(Socket) - 6", & 8"
  11.25 Bend - 6", & 8"
  22.5 Bend - 6", & 8"
  45 Bend - 6", & 8"
  90 Bend - 6", & 8"
  Reducer Socket - 8" x 6"
  Tee - 6", 8", & 8" x 6"
  Flange Tee - 6", 8", 6" x 4", 8" x 6", & 8" x 4"
  Flange socket - 6", & 8"

Pipe

PVC

iPVC Water Pipe

UL 1285
PC 235: 4" - 18"
PC 305: 4" - 16"

Pipe

PVC

Pyungwha PVC Pipe

UL 1285
PC 235: 4" - 16"
PC 305: 4" - 16"

Pipe

PVC

PVC Water Pipe

UL 1285
PC 235: 4" - 16"
PC 305: 4" - 16"

Pipe+

PVC

iPVC Water Pipe

FM 1612
14" - 16" DR 14 PC 305 and DR 18 PC 235
4" - 12" DR 14 PC 250 and DR 18 PC 185

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+

PVC

Pyungwha PVC Pipe

FM 1612
14" - 16" DR 14 PC 305 and DR 18 PC 235
4" - 12" DR 14 PC 250 and DR 18 PC 185

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+

PVC

PVC Water Pipe

FM 1612
14" - 16" DR 14 PC 305 and DR 18 PC 235
4" - 12" DR 14 PC 250 and DR 18 PC 185

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.



 
PPI PIPE Co., Ltd. 
1085-11, Beodeul-ro, Jangan-myeon
Hwaseong-si, Gyeonggi-do 445-941 
Republic of Korea 
82 31 359 0082
Visit this company's website

Facility : # 1 Gyeonggi-do, Republic of Korea

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Fittings#

MLTPL

iPVC fitting

UL 1285
PC 235: 4", 6", 8"
PC 305: 4", 6", 8"

# iPVC Fitting
  Coupling(Socket) - 6", & 8"
  Repair Coupling(Socket) - 6", & 8"
  11.25 Bend - 6", & 8"
  22.5 Bend - 6", & 8"
  45 Bend - 6", & 8"
  90 Bend - 6", & 8"
  Reducer Socket - 8" x 6"
  Tee - 6", 8", & 8" x 6"
  Flange Tee - 6", 8", 6" x 4", 8" x 6", & 8" x 4"
  Flange socket - 6", & 8"

Pipe

PVC

iPVC Water Pipe

UL 1285
PC 235: 4" - 18"
PC 305: 4" - 16"

Pipe+

PVC

iPVC Water Pipe

FM 1612
14" - 16" DR 14 PC 305 and DR 18 PC 235
4" - 12" DR 14 PC 250 and DR 18 PC 185

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe

PVC

Pyungwha PVC Pipe

UL 1285
PC 235: 4" - 16"
PC 305: 4" - 16"

Pipe+

PVC

Pyungwha PVC Pipe

FM 1612
14" - 16" DR 14 PC 305 and DR 18 PC 235
4" - 12" DR 14 PC 250 and DR 18 PC 185

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe

PVC

PVC Water Pipe

UL 1285
PC 235: 4" - 16"
PC 305: 4" - 16"

Pipe+

PVC

PVC Water Pipe

FM 1612
14" - 16" DR 14 PC 305 and DR 18 PC 235
4" - 12" DR 14 PC 250 and DR 18 PC 185

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.



 
R & H Import Inc. 
Unit 14 – 2166 Notre Dame Ave
Winnipeg, MB R3H 0K2 
Canada 
204-229-1566
Visit this company's website

Facility : Guangdong, China

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing# $ * [2] [10]

PEX

R&H PEX-b

ASTM E84
3/8", 1/2" - 2"

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[10] ASTM E84, 1/2" - 2" The Flame Spread Index and Smoke Developed Index for 1/2" - 2"
     tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi
     performance fiberglass insulation as per RIFENG installation instructions. The 3/8"
     tubing is not insulated.

Tubing$ & [2] [11]

PEX

R&H PEX-b

CAN/ULC S102.2
3/8", 1/2" - 2"

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[11] 3/8" Tubing (without insulation)
     Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
     1/2" through 2" Tubing (with insulation)
     Flame Spread Rating and Smoke Developed Classification based on when the tubing is field
     insulated with JM Microlok HP Hi Performance
     Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing
     shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[1] [3]

PEX

R&H PEX-b

ASTM E84
3/8" - 2"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[1] Certified for red and white PEX 5106 monowall pipe for Potable water application.
    Certified for red and white PEX 5006 for Radiant Heat Flooring application.
[3] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].

Tubing[1] [4]

PEX

R&H PEX-b

CAN/ULC S102.2
3/8" - 2"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[1] Certified for red and white PEX 5106 monowall pipe for Potable water application.
    Certified for red and white PEX 5006 for Radiant Heat Flooring application.
[4] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].

Tubing[5] [6]

PEX

R&H PEX-b

ASTM E84
3/8" - 1"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] Certified for blue,red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe for Potable water application. Certified for blue,red and white PPEX 5006 2-layer
    skinned and 4-layer barrier for Radiant Heat Flooring application.
[6] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance	fiberglass insulation as per RIFENG
    installation instructions (all listed construction/color/size combinations greater than
    or equal to 3/8" in diameter). Flame Spread Index and Smoke Developed Index based on
    minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM
    E84 FS<=25/SD<=50].

Tubing[5] [7]

PEX

R&H PEX-b

CAN/ULC S102.2
3/8" - 1"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] Certified for blue,red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe for Potable water application. Certified for blue,red and white PPEX 5006 2-layer
    skinned and 4-layer barrier for Radiant Heat Flooring application.
[7] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions (all listed construction/color/size
    combinations greater than or equal to 3/8" in diameter). Tubing shall be Marked
    [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[3] [8]

PEX

R&H PEX-a

ASTM E84
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[3] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[8] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.		
    Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[4] [8]

PEX

R&H PEX-a

CAN/ULC S102.2
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[8] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.		
    Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[3] [9]

PEX

R&H PEX-a

ASTM E84
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[3] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[9] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  
    Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
    Certified for red,  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
    sizes only.  

Tubing[4] [9]

PEX

R&H PEX-a

CAN/ULC S102.2
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[9] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  
    Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
    Certified for red,  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
    sizes only.  



 
REHAU Construction LLC 
1501 Edwards Ferry Road, N.E.
Leesburg, VA 20176 
United States 
800-247-9445 
703-777-5255
Visit this company's website

Facility : # 1 Cambodia

Fire Sprinkler Pipe and Fitting Systems

Product Type Material Type Trade Name Product Standard

Pipe and Fitting System% ** [G]

MLTPL

Rehau

ANSI/CAN/UL 1821

Couplings
3/4" x 3/4" (49970) 1" x 1" (499711) 1 1/4" x 1 1/4" (499712) 1 1/2" x 1 1/2" (499714)
2" x 2" (499715) 1" x 3/4" (499718) 1 1/4" x 3/4" (499721) 1 1/4" x 1" (499719)
1 1/2" x 1 1/4" (499723) 2" x 1 1/2" (499724)

Elbow
3/4" x 3/4" (499777) 1" x 1" (499778) 1 1/4" x 1 1/4" (499779) 1 1/2" x 1 1/2" (499780)
2" x 2" (499781)

Multi-Port Tee
3/4" x 3/4" in. Inlets, (2) 1/2 in. Outlets (499831) 3/4" x 3/4" in. Inlets, (3) 1/2 in. Outlets (499832) 3/4" x 3/4" in. Inlets, (4) 1/2 in. Outlets (499833) 3/4" x 3/4" in. Inlets, (6) 1/2 in. Outlets (499834)

Opposing Multi-Port Tee
3/4" x 3/4" Inlets, (3) 1/2 in. Outlets (499867) 3/4" x 3/4" Inlets, (4) 1/2 in. Outlets (499868) 3/4" x 3/4" Inlets, (6) 1/2 in. Outlets (499869)

Plug
3/4" (499771) 1" (499772) 1 1/4" (499773) 1 1/2" (499774)
2" (499775)

Reinforcing Rings
3/4" (499704) 1" (499705) 1 1/4" (499706) 1 1/2" (499707)
2" (499708)

Tee
3/4" x 3/4" x 3/4" (499729) 1" x 1" x 1" (499730) 1 1/4" x 1 1/4" x 1 1/4" (499731) 1 1/2" x 1 1/2" x 1 1/2" (499732)
2" x 2" x 2" (499733) 3/4" x 1/2 x 3/4" (499734) 1" x 3/4" x 1" (499735) 1 1/4" x 1" x 1 1/4" (499736)
1 1/2" x 1" x 1 1/2" (499737) 2" x 1 1/2" x 2" (499738) 3/4" x 3/4" x 1/2" (499739) 1" x 1" x 1/2" (499741)
1" x 1" x 3/4" (499740) 1 1/4" x 1 1/4" x 1/2" (499744) 1 1/4" x 1 1/4" x 3/4" (499743) 1 1/4" x 1 1/4" x 1" (499742)
1 1/2" x 1 1/2" x 3/4" (499753) 1 1/2" x 1 1/2" x 1" (499746) 1 1/2" x 1 1/2" x 1 1/4" (499747) 2" x 2" x 1" (499752)
2" x 2" x 1 1/4" (499748) 2" x 2" x 1 1/2" (499749) 1" x 3/4" x 3/4" (499755) 1 1/4" x 1" x 3/4" (499760)
1 1/4" x 1" x 1" (499756) 1 1/2" x 1 x 3/4" (499761) 1 1/2" x 1 x 1" (499757) 1 1/2" x 1 1/4" x 3/4" (499763)
1 1/2" x 1 1/4" x 1" (499762) 1 1/2" x 1 1/4" x 1 1/4" (499758) 1" x 1/2" x 1" (499845) 1 1/4" x 3/4" x 1 1/4" (499846)
1 1/2" x 3/4" x 1 1/2" (499847) 1 1/2" x 1 1/4" x 1 1/2" (499848) 2" x 1" x 2" (499849) 2" x 1 1/4" x 2" (499850)
1" x 3/4" x 1/2" (499851) 1 1/4" x 1" x 1/2" (499852) 1 1/2" x 1" x 1 1/4" (499853)

% PEX pipe and fittings are intended for use in multi-purpose piping systems of
  residential occupancies as
  defined in ANSI/NFPA 13D, “Installation of Sprinkler Systems in One- and Two- Family
  Dwellings and
  Manufactured Homes"" and the International Residential Code, Section P2904, and are
  designed to
  withstand a working pressure of not less than 130 psi at 120°F. PEX pipe and fittings
  are intended to be
  installed in accordance with the requirements specified in the manufacturer’s
  installation instructions
  and ANSI/NFPA 13D. Protection is intended to be provided for PEX pipe and fittings in
  multi-purpose
  piping systems unless otherwise stated in this listing and per the installation and
  design manual dated
  September 11, 2008. The minimum protection should consist of either (1) one layer of
  3/8-in. gypsum
  wallboard, (2) a suspended membrane ceiling with lay-in panels or tiles having a weight
  of not less than
  0.35 lbs per sq ft when installed with metallic support grids, OR (3) ½ in plywood. PEX
  pipe and
  fittings are intended for use in areas where the maximum ambient temperature does not
  exceed 120°F.
  These pipe and fittings are not intended to be installed in outdoor applications. The
  PEX pipe and
  fittings are intended for use in wet-pipe systems only and have not been evaluated for
  use in dry-pipe
  systems. Raupex pipe and fittings may also be installed without protection (exposed) in
  accordance with
  the limitations specified in this installation and design manual dated September 11,
  2008.
** Pipe and fittings Certified as a system using installation and design manual titled
   "FIREPEX Residential
   Fire Sprinkler
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


Facility : # 1 Germany

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing[3] [4]

PEX

Raupex® White UV Shield

CAN/ULC S102.2
1/2" - 2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+
    Fittings as per Rehau installation instructions. 
    Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].

Tubing[3] [4]

PEX

Raupex® Red UV Shield

CAN/ULC S102.2
1/2" - 2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+
    Fittings as per Rehau installation instructions. 
    Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].

Tubing* [1]

PEX

Municipex®

ASTM E84
3/4" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]

PEX

Municipex®

ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a   
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
    
    
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[2] [3]

PEX

Municipex®

CAN/ULC S102.2
3/4" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing* [1]

PEX

Raupex® O2 Barrier

ASTM E84
1/2" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing** [1]

PEX

Raupex® O2 Barrier

ASTM E84
<= 1/2"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
   
   
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[3]

PEX

Raupex® O2 Barrier

CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]

PEX

Raupex® O2 Barrier

CAN/ULC S102.2
5/8" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing* [1]

PEX

Raupex®

ASTM E84
1/2" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing** [1]

PEX

Raupex®

ASTM E84
<= 3/4"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
   
   
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]

PEX

Raupex®

ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a   
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
    
    
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[3]

PEX

Raupex®

CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]

PEX

Raupex®

CAN/ULC S102.2
1/2" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing* [1]

PEX

Raupex® Blue UV Shield

ASTM E84
1/2" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing** [1]

PEX

Raupex® Blue UV Shield

ASTM E84
<= 3/4"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
   
   
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]

PEX

Raupex® Blue UV Shield

ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a   
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
    
    
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[1] *****

PEX

Raupex® Blue UV Shield

ASTM E84
1/2" - 2"

[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
***** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
      with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with
      Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be
      marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing[3]

PEX

Raupex® Blue UV Shield

CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]

PEX

Raupex® Blue UV Shield

CAN/ULC S102.2
1/2" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing* [1]

PEX

Raupex® Red UV Shield

ASTM E84
1/2" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[3] [4]

PEX

Raupex® Blue UV Shield

CAN/ULC S102.2
1/2" - 2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+
    Fittings as per Rehau installation instructions. 
    Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].

Tubing** [1]

PEX

Raupex® Red UV Shield

ASTM E84
<= 3/4"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
   
   
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]

PEX

Raupex® Red UV Shield

ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a   
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
    
    
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[1] *****

PEX

Raupex® Red UV Shield

ASTM E84
1/2" - 2"

[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
***** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
      with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with
      Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be
      marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing[3]

PEX

Raupex® Red UV Shield

CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]

PEX

Raupex® Red UV Shield

CAN/ULC S102.2
1/2" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing* [1]

PEX

Raupex® White UV Shield

ASTM E84
1/2" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing** [1]

PEX

Raupex® White UV Shield

ASTM E84
<= 3/4"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
   
   
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]

PEX

Raupex® White UV Shield

ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a   
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
    
    
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[1] *****

PEX

Raupex® White UV Shield

ASTM E84
1/2" - 2"

[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
***** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
      with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with
      Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be
      marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing[3]

PEX

Raupex® White UV Shield

CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]

PEX

Raupex® White UV Shield

CAN/ULC S102.2
1/2" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]

PEX

RAUGEO

CAN/ULC S102.2
1/2" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.


Facility : # 2 Taiwan

Fire Sprinkler Pipe and Fitting Systems

Product Type Material Type Trade Name Product Standard

Pipe and Fitting System% ** [G]

PPSU

REHAU

ANSI/CAN/UL 1821

45 Deg, PEX to PEX Elbow
45 Deg Elbow 1 1/2 x 1 1/2 in. (499872) 45 Deg Elbow 2 x 2 in. (499873)

Branch + Run Reducing Tee
Tee, 3/4 x 1/2 x 1/2 in. (499754) Tee, 1 x 3/4 x 3/4 in. (499755) Tee, 1 1/4 x 1 x 1/2 in. (499852) Tee, 1 1/4 x 1 x 3/4 in. (499760)
Tee, 1 1/4 x 1 x 1 in. (499756) Tee, 1 1/2 x 1 x 3/4 in. (499761) Tee, 1 1/2 x 1 x 1 in. (499757) Tee, 1 1/2 x 1 x 1 1/4 in. (499853)
Tee, 1 1/2 x 1 1/4 x 3/4 in. (499763) Tee, 1 1/2 x 1 1/4 x 1 in. (499762) Tee, 1 1/2 x 1 1/4 x 1 1/4 in. (499758) Tee, 2 x 1 1/2 x 1/2 in. (499881)
Tee, 2 x 1 1/2 x 3/4 in. (499877) Tee, 2 x 1 1/2 x 1 in. (499878) Tee, 2 x 1 1/2 x 1 1/4 in. (499879) Tee, 2 x 1 1/2 x 1 1/2 in. (499880)

Branch Reducing Tee
Tee, 3/4 x 3/4 x 1/2 in. (499739) Tee, 1 x 1 x 1/2 in. (499741) Tee, 1 x 1 x 3/4 in. (499740) Tee, 1 1/4 x 1 1/4 x 1/2 in. (499744)
Tee, 1 1/4 x 1 1/4 x 3/4 in. (499743) Tee, 1 1/4 x 1 1/4 x 1 in. (499742) Tee 1 1/2 x 1 1/2 x 1/2 in. (499876) Tee, 1 1/2 x 1 1/2 x 3/4 in. (499753)
Tee, 1 1/2 x 1 1/2 x 1 in. (499746) Tee, 1 1/2 x 1 1/2 x 1 1/4 in. (499747) Tee, 2 x 2 x 1/2 in. (499883) Tee, 2 x 2 x 3/4 in. (499882)
Tee, 2 x 2 x 1 in. (499752) Tee, 2 x 2 x 1 1/4 in. (499748) Tee, 2 x 2 x 1 1/2 in. (499749)

Bullhead Tee
Tee, 1/2 x 1/2 x 3/4 in. (499767) Tee, 3/4 x 3/4 x 1 in. (499768)

PEX to PEX Elbow
Elbow, 3/4 x 1/2 in. (490318) Elbow, 3/4 x 3/4 in. (499777) Elbow, 1 x 1 in. (499778) Elbow, 1 1/4 x 1 1/4 in. (499779)
Elbow, 1 1/2 x 1 1/2 in. (499780) Elbow, 2 x 2 in. (499781)

Plug
Plug, 3/4 in. (499771) Plug, 1 in. (499772) Plug, 1 1/4 in. (499773) Plug, 1 1/2 in. (499774)
Plug, 2 in. (499775)

Reducing Coupling
Coupling, 3/4 x 1/2 in. (499717) Coupling, 1 x 1/2 in. (490319) Coupling, 1 x 3/4 in. (499718) Coupling, 1 1/4 x 3/4 in. (499721)
Coupling, 1 1/4 x 1 in. (499719) Coupling, 1 1/2 x 3/4 in. (499874) Coupling 1 1/2 x 1 in. (499875) Coupling, 1 1/2 x 1 1/4 in. (499723)
Coupling, 2 x 1 1/2 in. (499724)

Run Reducing Tee
Tee, 3/4 x 1/2 x 3/4 in. (499734) Tee, 1 x 3/4 x 1 in. (499735) Tee 1 1/4 x 3/4 x 1 1/4 in. (499846) Tee 1 1/4 x 1 x 1 1/4 in. (499736)
Tee, 1 1/2 x 3/4 x 1 1/2 in. (499847) Tee, 1 1/2 x 1 x 1 1/2 in. (499737) Tee, 1 1/2 x 1 1/4 x 1 1/2 in. (499848) Tee, 2 x 1 x 2 in. (499849)
Tee, 2 x 1 1/4 x 2 in. (499850) Tee, 2 x 1 1/2 x 2 in. (499738)

Straight Coupling
Coupling, 3/4 x 3/4 in. (499710) Coupling, 1 x 1 in. (499711) Coupling, 1 1/4 x 1 1/4 in. (499712) Coupling, 1 1/2 x 1 1/2 in. (499714)
Coupling, 2 x 2 in. (499715)

Straight Tee
Tee, 3/4 x 3/4 x 3/4 in. (499729) Tee, 1 x 1 x 1 in. (499730) Tee, 1 1/4 x 1 1/4 x 1 1/4 in. (499731) Tee, 1 1/2 x 1 1/2 x 1 1/2 in. (499732)
Tee, 2 x 2 x 2 in. (499733)

% PEX pipe and fittings are intended for use in multi-purpose piping systems of
  residential occupancies as defined in ANSI/NFPA 13D, “Installation of Sprinkler Systems
  in One- and Two- Family Dwellings and Manufactured Homes"" and the International
  Residential Code, Section P2904, and are designed to withstand a working pressure of not
  less than 130 psi at 120°F. PEX pipe and fittings are intended to be installed in
  accordance with the requirements specified in the manufacturer’s installation
  instructions and ANSI/NFPA 13D. Protection is intended to be provided for PEX pipe and
  fittings in multi-purpose piping systems unless otherwise stated in this listing and per
  the installation and design manual dated September 11, 2008. The minimum protection
  should consist of either (1) one layer of 3/8-in. gypsum wallboard, (2) a suspended
  membrane ceiling with lay-in panels or tiles having a weight of not less than 0.35 lbs
  per sq ft when installed with metallic support grids, OR (3) ½ in plywood. PEX pipe and
  fittings are intended for use in areas where the maximum ambient temperature does not
  exceed 120°F. These pipe and fittings are not intended to be installed in outdoor
  applications. The PEX pipe and fittings are intended for use in wet-pipe systems only
  and have not been evaluated for use in dry-pipe systems. Raupex pipe and fittings may
  also be installed without protection (exposed) in accordance with the limitations
  specified in this installation and design manual dated September 11, 2008.
** Pipe and fittings Certified as a system using installation and design manual titled
   "FIREPEX Residential
   Fire Sprinkler Systems".
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


Facility : # 7 USA

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing* [1]

PEX

Municipex®

ASTM E84
3/4" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]

PEX

Municipex®

ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[2] [3]

PEX

Municipex®

CAN/ULC S102.2
3/4" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing* [1]

PEX

Municipex® Reclaim

ASTM E84
3/4" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]

PEX

Municipex® Reclaim

ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[2] [3]

PEX

Municipex® Reclaim

CAN/ULC S102.2
3/4" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing** [1]

PEX

Raupex® O2 Barrier

ASTM E84
<= 1/2"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing* [1]

PEX

Raupex® O2 Barrier

ASTM E84
5/8" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[3]

PEX

Raupex® O2 Barrier

CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]

PEX

Raupex® O2 Barrier

CAN/ULC S102.2
5/8" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing** [1]

PEX

Raupex®

ASTM E84
<= 3/4"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing* [1]

PEX

Raupex®

ASTM E84
5/8" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]

PEX

Raupex®

ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[3]

PEX

Raupex®

CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]

PEX

Raupex®

CAN/ULC S102.2
5/8" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing** [1]

PEX

Raupex® Blue UV Shield

ASTM E84
<= 3/4"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing* [1]

PEX

Raupex® Blue UV Shield

ASTM E84
5/8" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]

PEX

Raupex® Blue UV Shield

ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[1] ****

PEX

Raupex® Blue UV Shield

ASTM E84
1/2" - 2"

[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
**** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
     with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with
     Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be
     marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing[3]

PEX

Raupex® Blue UV Shield

CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]

PEX

Raupex® Blue UV Shield

CAN/ULC S102.2
5/8" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[3] [4]

PEX

Raupex® Blue UV Shield

CAN/ULC S102.2
1/2" - 2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+
    Fittings as per Rehau installation instructions.
    Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].

Tubing** [1]

PEX

Raupex® Red UV Shield

ASTM E84
<= 3/4"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing* [1]

PEX

Raupex® Red UV Shield

ASTM E84
5/8" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]

PEX

Raupex® Red UV Shield

ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[1] ****

PEX

Raupex® Red UV Shield

ASTM E84
1/2" - 2"

[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
**** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
     with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with
     Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be
     marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing[3]

PEX

Raupex® Red UV Shield

CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]

PEX

Raupex® Red UV Shield

CAN/ULC S102.2
5/8" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[3] [4]

PEX

Raupex® Red UV Shield

CAN/ULC S102.2
1/2" - 2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+
    Fittings as per Rehau installation instructions.
    Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].

Tubing** [1]

PEX

Raupex® White UV Shield

ASTM E84
<= 3/4"

** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs with Everloc+P, Everloc+ fittings.  Tubing shall be marked [NSF®-fs
   ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing* [1]

PEX

Raupex® White UV Shield

ASTM E84
5/8" - 2"

* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
  with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau
  installation instructions.
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing*** [1]

PEX

Raupex® White UV Shield

ASTM E84
3/4" - 2"

*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
    using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
    maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
    marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
    
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.

Tubing[1] ****

PEX

Raupex® White UV Shield

ASTM E84
1/2" - 2"

[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
**** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
     with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with
     Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be
     marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing[3]

PEX

Raupex® White UV Shield

CAN/ULC S102.2
<= 1/2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[2] [3]

PEX

Raupex® White UV Shield

CAN/ULC S102.2
5/8" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.

Tubing[3] [4]

PEX

Raupex® White UV Shield

CAN/ULC S102.2
1/2" - 2"

[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+
    Fittings as per Rehau installation instructions.
    Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].

Tubing[2] [3]

PEX

RAUGEO

CAN/ULC S102.2
3/4" - 2"

[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
    with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
    instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.


Fire Sprinkler Pipe and Fitting Systems

Product Type Material Type Trade Name Product Standard

Pipe and Fitting System% ** [G]

MLTPL

FIREPEX™ Residential Fire Sprinkler Systems

ANSI/CAN/UL 1821

45 Deg, PEX to PEX Elbow
45 Deg Elbow 1 1/2 x 1 1/2 in. (499872) 45 Deg Elbow 2 x 2 in. (499873)

90 Degree Elbow
3/4" x 3/4" (F209E66) 1" x 1" (F209E88) 1 1/4" x 1 1/4" (F20E10)

Adapter, PEX to CP
1/2" x 3/4" 3/4" x 3/4" 3/4" x 1" 1" x 3/4"
1" x 1" 1 1/4" x 1 1/4" 1 1/2" x 1 1/2" 2" x 2"

Adapter, PEX to Copper
1/2" x 3/4" Male (499790) 1/2" x 3/4" Female (499793) 3/4" x 1/2" Male (499792) 3/4" x 1/2" Female
5/8'' x 3/4'' Male (499861) 5/8'' x 3/4'' Female (499862) 3/4" x 3/4" Male (499796) 3/4" x 3/4" Female (499797)
3/4" x 1" Male (499791) 3/4" x 1" Female (499798) 1" x 1" Male (499799) 1" x 1" Female (499800)
1 1/4" x 1 1/4" Male (499801) 1 1/4" x 1 1/4" Female (499802) 1 1/2" x 1 1/2" Male (499803) 1 1/2" x 1 1/2" Female (499804)
2" x 2" Male (499805) 2" x 2" Female (499806)

Adapter, PEX to FPT
1/2" x 3/4" (499819) 3/4" x 3/4" (499822) 3/4" x 1" (499820) 1" x 3/4"
1" x 1" (499823) 1 1/4" x 1 1/4" (499863) 1 1/2" x 1 1/2" (499864) 2" x 2" (499866)

Adapter, PEX to MPT
1/2" x 3/4" (499810) 3/4" x 3/4" (499808) 3/4" x 1" (499814) 1" x 3/4" (499809)
1" x 1" (499815) 1 1/4" x 1 1/4" (499816) 1 1/2" x 1 1/2" (499817) 2" x 2" (499818)

Branch + Run Reducing Tee
Tee, 3/4 x 1/2 x 1/2 in. (499754) Tee, 1 x 3/4 x 3/4 in. (499755) Tee, 1 1/4 x 1 x 1/2 in. (499852) Tee, 1 1/4 x 1 x 3/4 in. (499760)
Tee, 1 1/4 x 1 x 1 in. (499756) Tee, 1 1/2 x 1 x 3/4 in. (499761) Tee, 1 1/2 x 1 x 1 in. (499757) Tee, 1 1/2 x 1 x 1 1/4 in. (499853)
Tee, 1 1/2 x 1 1/4 x 3/4 in. (499763) Tee, 1 1/2 x 1 1/4 x 1 in. (499762) Tee, 1 1/2 x 1 1/4 x 1 1/4 in. (499758) Tee, 2 x 1 1/2 x 1/2 in. (499881)
Tee, 2 x 1 1/2 x 3/4 in. (499877) Tee, 2 x 1 1/2 x 1 in. (499878) Tee, 2 x 1 1/2 x 1 1/4 in. (499879) Tee, 2 x 1 1/2 x 1 1/2 in. (499880)

Branch Reducing Tee
Tee, 3/4 x 3/4 x 1/2 in. (499739) Tee, 1 x 1 x 1/2 in. (499741) Tee, 1 x 1 x 3/4 in. (499740) Tee, 1 1/4 x 1 1/4 x 1/2 in. (499744)
Tee, 1 1/4 x 1 1/4 x 3/4 in. (499743) Tee, 1 1/4 x 1 1/4 x 1 in. (499742) Tee 1 1/2 x 1 1/2 x 1/2 in. (499876) Tee, 1 1/2 x 1 1/2 x 3/4 in. (499753)
Tee, 1 1/2 x 1 1/2 x 1 in. (499746) Tee, 1 1/2 x 1 1/2 x 1 1/4 in. (499747) Tee, 2 x 2 x 1/2 in. (499883) Tee, 2 x 2 x 3/4 in. (499882)
Tee, 2 x 2 x 1 in. (499752) Tee, 2 x 2 x 1 1/4 in. (499748) Tee, 2 x 2 x 1 1/2 in. (499749)

Bullhead Tee
Tee, 1/2 x 1/2 x 3/4 in. (499767) Tee, 3/4 x 3/4 x 1 in. (499768)

Couplings
3/4" x 3/4" (49970) 1" x 1" (499711) 1 1/4" x 1 1/4" (499712) 1 1/2" x 1 1/2" (499714)
2" x 2" (499715) 1" x 3/4" (499718) 1 1/4" x 3/4" (499721) 1 1/4" x 1" (499719)
1 1/2" x 1 1/4" (499723) 2" x 1 1/2" (499724)

Drop Ear Elbow, PEX to FPT
3/4" x 3/4" (499787)

EVERLOC+ LF 45 DEG Elbow
1 1/2" x 1 1/2" (425021) 2" x 2" (425022)

EVERLOC+ LF Adapter
1/2" x 1/2" CF (317184) 3/4" x 3/4" MPT (317172) 3/4" x 3/4" FPT (317182) 3/4" x 3/4" CM (317186)
3/4" x 3/4" CF (317187) (499797) 3/4" x 1" MPT (317177) 3/4" x 1" CF (317189) 1" x 3/4" MPT (323708)
1" x 3/4" FPT (329227) 1" x 1" MPT (317178) 1" x 1" FPT (317183) 1" x 1" CM (317190)
1" x 1" CF (317191) (499800) 1 1/4" x 1 1/4" MPT (317179) 1 1/4" x 1 1/4" CM (317192) 1 1/4" x 1 1/4" CF (317193)
1 1/2" x 1 1/2" MPT (317180) 1 1/2" x 1 1/2" CM (317194) 1 1/2" x 2" CM or 1 1/2" CF (317195) 2" x 2" MPT (317181)
2" x 2" CM (317196) 2" x 2" CF (317197)

EVERLOC+ LF Coupling
1-1/4" x 3/4" (425026) 1-1/2" x 3/4" (425028) 2" x 3/4" (425031) 2" x 1" (317139)
2" x 1 1/4" (317140) 2" x 1 1/2" (317141)

EVERLOC+ LF Elbows
3/4" x 3/4" CM (317166) 3/4" (317167) 3/4" x 3/4" MPT (317169) 3/4" x 3/4" FPT (422006)
3/4"x 3/4" MPT (425476) 1" x 1" FPT (422007)

EVERLOC+ LF Tees
1 1/4" x 1" x 3/4" (424989) 1 1/4" x 1 1/4" x 1/2" (424991) 1 1/4" x 1 1/4" x 3/4" (322832) 1 1/2" x 1 1/4" x 1" (317153)
2" x 1 1/2" x 1 1/4" (317161) 1 1/2" x 1 1/4" x 1 1/2" (317145) 2" x 1 1/2" x 1 1/2" (317155) 1 1/2" x 1 1/2" x 3/4" (322833)
2" x 1 1/2" x 2" (317147) 1 1/2" x 1 1/2" x 1/2" (425024) 1 1/2" x 1 1/4" x 3/4" (425025) 1 1/2" x 1" x 3/4" (424992)
2" x 1 1/4" x 2" (317146) 2" x 2" x 3/4" (322834) 2" x 1 1/2" x 1" (317156) 2" x 1 1/2" x 3/4" (424994)
2" x 2" x 1/2" (424995)

EVERLOC+ Manifold Sweat Adapter
3/4" X 1" CF (326712) 1" X 1" CM (326713)

EVERLOC+ Polymer 45° Elbow
2” x 2” 1 ½” x 1 ½”

EVERLOC+ Polymer Coupling
1 ½” x ¾” (435705) 2” x 1 ½” (435706) 2” x 1 ¼” 1 ½” x 1 ¼” (435704)
2” x 1” 1 ¼” x ¾” (435718)

EVERLOC+P Coupling
3/4" x 3/4" (104825) 1" x 3/4" (104831) 1" x 1" (104826) 1 1/4" x 1" (104832)
1 1/4" x 1 1/4" (104827) 1 1/2" x 1" (104833) 1 1/2" x 1 1/2" (104828) 2" x 2" (104829)

EVERLOC+P Elbow
3/4" x 3/4" (104860) 1" x 1" (104861) 1 1/4" x 1 1/4" (104862) 1 1/2" x 1 1/2" (104863)
2" x 2" (104864)

EVERLOC+P Plug
3/4" (104857) 1" (104858) 1 1/4" (317158) 1 1/2" (317159)
2" (317160)

EVERLOC+P Tee
3/4" x 1/2" x 3/4" (104841) 3/4" x 3/4" x 3/4" (104836) 3/4" x 3/4" x 1" (104855) 1" x 3/4" x 3/4" (104852)
1" x 3/4" x 1" (104842) 1" x 1" x 1" (104837) 1 1/4" x 1" x 1" (104853) 1 1/4" x 1 1/4" x 1 1/4" (104838)
1 1/4" x 1 1/4" x 1" (104847) 1 1/2" x 1 1/2" x 1" (104848) 1 1/2" x 1 1/2" x 1 1/2" (104839) 2" x 2" x 1" (104849)
2" x 2" x 2" (104840)

EVERLOC+Sleeves
3/4" (104818) 1" (104819) 1 1/4" (104820) 1 1/2" (104821)
2" (104822)

Elbow
3/4" x 3/4" (499777) 1" x 1" (499778) 1 1/4" x 1 1/4" (499779) 1 1/2" x 1 1/2" (499780)
2" x 2" (499781)

Elbow, PEX to CP
3/4" x 3/4"

Elbow, PEX to Copper
3/4" x 3/4" Male (499784) 3/4" x 3/4" Female (499785) 5/8" x 3/4" Male (499857) 5/8" x 3/4" Female (499858)

Everloc+ Polymer Tee
1" x ¾” x ½” (435701) 1 ½” x 1” x ¾” 1 ½” x 1 ¼” x 1 ½” 2” x 1 ¼” x 2”
2” x 2” x ½” 1 ½” x 1 ½” x 1 ¼” (435713) 1 ½” x 1” x 1” (435719) 1 ½” x 1” 1 ½” (435709)
2” x 1 ½” x ¾” 2” x 2” x 1 ¼” (435714) 2” x 2” x 1 ½” (435710) 2” x 1 ½” x 1”
2” x 1 ½” x 1 ¼” 2” x 1 ½” x 1 ½” 1 ½” x 1 ½” x ½” (435707) 1 ½” x 1 ½” x ¾” (435702)
2” x 1 ½” x 2” 2” x 2” x ¾” (435721) 1 ¼” x 1” x ¾” 1 ¼” x 1” x 1 ¼” (435712)
1 ¼” x 1 ¼” x ½” (435703) 1" x ½” x 1" (435809) 1 ¼” x ¾” x ¾” (435715) 1 ¼” x ¾” x 1 ¼” (435717)
1 ½” x 1 ¼” x ¾” (435711) 1 ½” x 1 ¼” x 1” 1 ½” x 1 ¼” x 1 ¼” (435720) 1 ¼” x 1 ¼” x ¾” (435700)
1 ½” x ¾” x 1 ½” (435716)

Everloc+ Stub Ell
3/4" 8" (418668) (499364) 3/4" 8" with mounting plate (329229) (499307) 1" 8" (499365)

LF Brass Adapter
3/4" x 3/4" C Female (499797) 1" x 1" C Female (499800)

Male Threaded Adapter
3/4" x 3/4" (F96E66) 1" x 1" (F96E88) 1 1/4" x 1 1/4" (F96E1010)

Multi-Port Tee
3/4" x 3/4" in. Inlets, (2) 1/2 in. Outlets (499831) 3/4" x 3/4" in. Inlets, (3) 1/2 in. Outlets (499832) 3/4" x 3/4" in. Inlets, (4) 1/2 in. Outlets (499833) 3/4" x 3/4" in. Inlets, (6) 1/2 in. Outlets (499834)

Opposing Multi-Port Tee
3/4" x 3/4" Inlets, (3) 1/2 in. Outlets (499867) 3/4" x 3/4" Inlets, (4) 1/2 in. Outlets (499868) 3/4" x 3/4" Inlets, (6) 1/2 in. Outlets (499869)

PEX to PEX Elbow
Elbow, 3/4 x 1/2 in. (490318) Elbow, 3/4 x 3/4 in. (499777) Elbow, 1 x 1 in. (499778) Elbow, 1 1/4 x 1 1/4 in. (499779)
Elbow, 1 1/2 x 1 1/2 in. (499780) Elbow, 2 x 2 in. (499781)

Plug
3/4" F2080 (F103E6) 1" F2080 (F103E8) 1 1/4" F2080 (F103E10) Plug, 3/4 in. (499771)
Plug, 1 in. (499772) Plug, 1 1/4 in. (499773) Plug, 1 1/2 in. (499774) Plug, 2 in. (499775)

Reducing Coupling
3/4" x 1/2" (F95E64) 1 X 3/4" (F95E86) 1 1/4" X 1" (F95E108) Coupling, 3/4 x 1/2 in. (499717)
Coupling, 1 x 1/2 in. (490319) Coupling, 1 x 3/4 in. (499718) Coupling, 1 1/4 x 3/4 in. (499721) Coupling, 1 1/4 x 1 in. (499719)
Coupling, 1 1/2 x 3/4 in. (499874) Coupling 1 1/2 x 1 in. (499875) Coupling, 1 1/2 x 1 1/4 in. (499723) Coupling, 2 x 1 1/2 in. (499724)

Reinforcing Rings
3/4" (499704) 1" (499705) 1 1/4" (499706) 1 1/2" (499707)
2" (499708)

Run Reducing Tee
Tee, 3/4 x 1/2 x 3/4 in. (499734) Tee, 1 x 3/4 x 1 in. (499735) Tee 1 1/4 x 3/4 x 1 1/4 in. (499846) Tee 1 1/4 x 1 x 1 1/4 in. (499736)
Tee, 1 1/2 x 3/4 x 1 1/2 in. (499847) Tee, 1 1/2 x 1 x 1 1/2 in. (499737) Tee, 1 1/2 x 1 1/4 x 1 1/2 in. (499848) Tee, 2 x 1 x 2 in. (499849)
Tee, 2 x 1 1/4 x 2 in. (499850) Tee, 2 x 1 1/2 x 2 in. (499738)

Sprinkler Elbows
3/4" x 1/2" FPT (422004) 1" x 1/2" FPT (422005)

Sprinkler Flow Through
1” F1960 x 1/2" FPT (802407)

Sprinkler Tees
3/4" x 3/4" x 1/2" FPT (421744) 1" x 1" x 1/2" FPT (421878)

Straight Coupling
Coupling, 3/4 x 3/4 in. (499710) Coupling, 1 x 1 in. (499711) Coupling, 1 1/4 x 1 1/4 in. (499712) Coupling, 1 1/2 x 1 1/2 in. (499714)
Coupling, 2 x 2 in. (499715)

Straight Tee
Tee, 3/4 x 3/4 x 3/4 in. (499729) Tee, 1 x 1 x 1 in. (499730) Tee, 1 1/4 x 1 1/4 x 1 1/4 in. (499731) Tee, 1 1/2 x 1 1/2 x 1 1/2 in. (499732)
Tee, 2 x 2 x 2 in. (499733)

Stub Ell 8"
3/4" (499364) 1" (499365)

Stub Ell 8" with mounting plate
3/4" (499307)

Tees
3/4" x 3/4" x 3/4" (499729) 1" x 1" x 1" (499730) 1 1/4" x 1 1/4" x 1 1/4" (499731) 1 1/2" x 1 1/2" x 1 1/2" (499732)
2" x 2" x 2" (499733) 3/4" x 1/2" x 3/4" (499734) 1" x 3/4" x 1" (499735) 1 1/4" x 1 x 1 1/4" (499736)
1 1/2" x 1" x 1 1/2" (499737) 2" x 1 1/2" x 2" (499738) 3/4" x 3/4" x 1/2" (499739) 1" x 1" x 1/2" (499741)
1" x 1" x 3/4" (499740) 1 1/4" x 1 1/4" x 1/2" (499744) 1 1/4" x 1 1/4" x 3/4" (499743) 1 1/4" x 1 1/4" x 1" (499742)
1 1/2" x 1 1/2" x 3/4" (499753) 1 1/2" x 1 1/2" x 1" (499746) 1 1/2" x 1 1/2" x 1 1/4" (499747) 2" x 2" x 1" (499752)
2" x 2" x 1 1/4" (499748) 2" x 2" x 1 1/2" (499749) 1" x 3/4" x 3/4" (499755) 1 1/4" x 1" x 3/4" (499760)
1 1/4" x 1" x 1" (499756) 1 1/2" x 1" x 3/4" (499761) 1 1/2" x 1" x 1" (499757) 1 1/2" x 1 1/4" x 3/4" (499763)
1 1/2" x 1 1/4" x 1" (499762) 1 1/2" x 1 1/4" x 1 1/4" (499758) 1" x 1/2" x 1" (499845) 1 1/4" x 3/4" x 1 1/4" (499846)
1 1/2" x 3/4" x 1 1/2" (499847) 1 1/2" x 1 1/4" x 1 1/2" (499848) 2" x 1" x 2" (499849) 2" x 1 1/4" x 2" (499850)
1" x 3/4" x 1/2" (499851) 1 1/4" x 1" x 1/2" (499852) 1 1/2" x 1" x 1 1/4" (499853) 3/4" x 1/2" x 1/2" [F208E644]
3/4" x 1/2" x 3/4" [F208E646] 3/4" x 3/4" x 1/2" [F208E664] 3/4" x 3/4" x 3/4" [F208E666] 1" x 1" x 3/4" [F208E886]
1" x 1" x 1" [F208E888] 1 1/4" x 3/4" x 1" [F208E1068] 1 1/4" x 1 1/4" x 3/4" [F208E10106] 1 1/4" x 1 1/4" x 1" [F208E10108]

Tubing
3/4" – 2" Raupex 3/4" - 2" Raupex White UV- Shield

% PEX pipe and fittings are intended for use in multi-purpose piping systems of
  residential occupancies as defined in ANSI/NFPA 13D, “Installation of Sprinkler Systems
  in One- and Two- Family Dwellings and Manufactured Homes" and the International
  Residential Code, Section P2904, and are designed to withstand a working pressure of not
  less than 130 psi at 120°F.  PEX pipe and fittings are intended to be installed in
  accordance with the requirements specified in the manufacturer’s installation
  instructions and ANSI/NFPA 13D.  Protection is intended to be provided for PEX pipe and
  fittings in multi-purpose piping systems unless otherwise stated in this listing and per
  the installation and design manual dated September 11, 2008.  The minimum protection
  should consist of either (1) one layer of 3/8-in. gypsum wallboard, (2) a suspended
  membrane ceiling with lay-in panels or tiles having a weight of not less than 0.35 lbs
  per sq ft when installed with metallic support grids, OR (3) ½ in plywood.  PEX pipe and
  fittings are intended for use in areas where the maximum ambient temperature does not
  exceed 120°F. These pipe and fittings are not intended to be installed in outdoor
  applications.  The PEX pipe and fittings are intended for use in wet-pipe systems only
  and have not been evaluated for use in dry-pipe systems.  Raupex pipe and fittings may
  also be installed without protection (exposed) in accordance with the limitations
  specified in this installation and design manual dated September 11, 2008.
** Pipe and fittings Certified as a system using installation and design manual titled
   "FIREPEX Residential Fire Sprinkler Systems".
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


Facility : EU

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing[1] [2]

PEX

NEOPEX O2 Barrier

ASTM E84
1/2", 5/8", 3/4"

[1] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[2] 1/2", 5/8"  3/4" Flame Spread Index and Smoke Developed Index based on when tubing is
    field insulated	with 1/2" Micro-lok HP Hi performance fiberglass insulation as per Rehau
    installation instructions.
    
    1/2" Only: Flame Spread Index and Smoke Developed Index based on minimum spacing of 18
    inches between tubing runs with Everloc+P, Everloc+ fittings.
    
    Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].

Tubing[1] [3]

PEX

NEOPEX O2 Barrier

CAN/ULC S102.2
1/2", 5/8", 3/4"

[1] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[3] 1/2" - Non-insulated 
    
    5/8" & 3/4": Flame Spread Index and Smoke Developed Index based on when tubing is field
    instructions. insulated with minimum 1/2" JM Microlok or Armaflex insulation as per
    Rehau installation.
    
    Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].



 
Rifeng Enterprise (Foshan) Co., Ltd. 
No.1 Rifeng Road
Foshan, Guangdong 528317 
China 
86 757 8230 1768

Facility : Foshan, China

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing# $ * [2] [10]

PEX

Rifeng

ASTM E84
3/8", 1/2" - 2"

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[10] ASTM E84, 1/2" - 2" The Flame Spread Index and Smoke Developed Index for 1/2" - 2"
     tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi
     performance fiberglass insulation as per RIFENG installation instructions. The 3/8"
     tubing is not insulated.

Tubing$ & [2] [11]

PEX

Rifeng

CAN/ULC S102.2
3/8", 1/2" - 2"

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[11] 3/8" Tubing (without insulation)
     Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
     1/2" through 2" Tubing (with insulation)
     Flame Spread Rating and Smoke Developed Classification based on when the tubing is field
     insulated with JM Microlok HP Hi Performance
     Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing
     shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[1] [3]

PEX

RIFENG PEX

ASTM E84
3/8" - 2"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[1] Certified for red and white PEX 5106 monowall pipe for Potable water application.
    Certified for red and white PEX 5006 for Radiant Heat Flooring application.
[3] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].

Tubing[1] [4]

PEX

RIFENG PEX

CAN/ULC S102.2
3/8" - 2"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[1] Certified for red and white PEX 5106 monowall pipe for Potable water application.
    Certified for red and white PEX 5006 for Radiant Heat Flooring application.
[4] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].

Tubing[5] [6]

PEX

RIFENG PEX

ASTM E84
3/8" - 1"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] Certified for blue,red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe for Potable water application. Certified for blue,red and white PPEX 5006 2-layer
    skinned and 4-layer barrier for Radiant Heat Flooring application.
[6] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance	fiberglass insulation as per RIFENG
    installation instructions (all listed construction/color/size combinations greater than
    or equal to 3/8" in diameter). Flame Spread Index and Smoke Developed Index based on
    minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM
    E84 FS<=25/SD<=50].

Tubing[5] [7]

PEX

RIFENG PEX

CAN/ULC S102.2
3/8" - 1"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] Certified for blue,red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe for Potable water application. Certified for blue,red and white PPEX 5006 2-layer
    skinned and 4-layer barrier for Radiant Heat Flooring application.
[7] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions (all listed construction/color/size
    combinations greater than or equal to 3/8" in diameter). Tubing shall be Marked
    [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[3] [8]

PEX

RIFENG PEXa

ASTM E84
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[3] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[8] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.		
    Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[4] [8]

PEX

RIFENG PEXa

CAN/ULC S102.2
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[8] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.		
    Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[3] [9]

PEX

RIFENG PEXa

ASTM E84
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[3] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[9] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  
    Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
    Certified for red,  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
    sizes only.  

Tubing[4] [9]

PEX

RIFENG PEXa

CAN/ULC S102.2
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[9] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  
    Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
    Certified for red,  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
    sizes only.  



 
Riifo North America 
4737 Smokey Bear Lane
Columbia Falls, MT 59912 
United States 
406-250-4412

Facility : # 1 China

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing# $ *

PEX

Riifo

ASTM E84

3/8", 1/2" - 2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing$ &

PEX

Riifo

CAN/ULC S102.2

3/8", 1/2" - 2"
Flame Spread Rating <= 25 Smoke Developed Classification <= 50

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].



 
S & B Technical Products, Inc. / Terramix S.A./dBa Hultec, Inc. 
2170 Buckthorn Pl
Suite 450 
Spring, TX 77380 
United States 
800-432-8213 
817-923-3344

Facility : Spring, TX

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Gaskets+

EPDM

EPDM HT533 Hydrogrip AG

FM 1612
4" - 30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Gaskets+

EPDM

EPDM HT533 Hydrogrip CIOD

FM 1612
4" - 30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Gaskets+

EPDM

EPDM HT533 Hydrogrip IPS

FM 1612
4" - 30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Gaskets+

EPDM

SBR HT627 Hydrogrip AG

FM 1612
4" - 30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Gaskets+

EPDM

SBR HT627 Hydrogrip CIOD

FM 1612
4" - 30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Gaskets+

EPDM

SBR HT627 Hydrogrip IPS

FM 1612
4" - 30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.


Facility : Santa Ana, Costa Rica (Hultec)

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Gaskets+

EPDM

EPDM HT533 Hydrogrip AG

FM 1612
4" - 30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Gaskets+

EPDM

EPDM HT533 Hydrogrip CIOD

FM 1612
4" - 30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Gaskets+

EPDM

EPDM HT533 Hydrogrip IPS

FM 1612
4" - 30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Gaskets+

SBR

SBR HT627 Hydrogrip AG

FM 1612
4" - 30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Gaskets+

SBR

SBR HT627 Hydrogrip CIOD

FM 1612
4" - 30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Gaskets+

SBR

SBR HT627 Hydrogrip IPS

FM 1612
4" - 30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Gaskets+ [1]

EPDM

EPDM HT553 Rieberlok Gasket

UL 1285
4" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 C900 1 Piece RR

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 C900 CIOD DD

UL 1285
4" - 18"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 C900 Platinum Pressure

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 C900 Rieber

UL 1285
2" - 16"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 C900 Super Rieber Patented

UL 1285
2" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 C905 1 Piece RR

UL 1285
14" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 C905 Platinum Pressure

UL 1285
14" - 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 C905 Super Rieber Patented

UL 1285
14" - 48"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 C909 Biax Mambo

UL 1285
4" - 16"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 Fast Grip

UL 1285
4" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 Fastite Gasket

UL 1285
4" - 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 Field LOK

UL 1285
4" - 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 FIELD LOK 350®

UL 1285
4" - 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 Flange Tyte

UL 1285
4" - 64"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 Full Face Flange Tyte

UL 1285
4" - 64"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 IPS 2241 Rieber

UL 1285
1 1/2" - 18"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 IPS 2241 Super Rieber

UL 1285
14" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 IPS Biax Mambo

UL 1285
3" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 IPS Hero

UL 1285
1 1/2" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 LOKX System DIPS

UL 1285
4"-12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 LOKX System IPS

UL 1285
4"-12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 Metric Pressure

UL 1285
50 mm - 630 mm

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 Metric Tyton

UL 1285
80 mm - 1200 mm

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 MJ Field Lok

UL 1285
4" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 One Piece Retainer Ring CIOD

UL 1285
4" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 PIP DD

UL 1285
10" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 PR IPS

UL 1285
6" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 Rest MJ (PVC)

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 Rieber IPS

UL 1285
1 1/2" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 S-Ring

UL 1285
6" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 Sure Stop

UL 1285
4" - 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 T Saddle IP

UL 1285
4" - 6"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 TURNER BIAX C909

UL 1285
4" - 16"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 TURNER BIAX IPS

UL 1285
4" - 16"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 TURNER C909

UL 1285
4" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 TURNER C909 TYPE C

ASTM F477
6" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 Turner Lock

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 Tyton CM

UL 1285
3" - 42"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 TYTON GASKET

UL 1285
3" - 64"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 USIFLEX

UL 1285
30" - 54"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 Y Saddle IP

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 C900 1 Piece RR

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 C900 CIOD DD

UL 1285
4" - 18"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 C900 Platinum Pressure

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 C900 Rieber

UL 1285
2" - 16"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 C900 Super Rieber Patented

UL 1285
2" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 C905 1 Piece RR

UL 1285
14" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 C905 B/C Ring Certalok

UL 1285
>= 4"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 C905 Platinum Pressure

UL 1285
14" - 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 C905 Super Rieber Patented

UL 1285
14" - 48"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 C909 Biax Mambo

UL 1285
4" - 16"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 Fast Grip

UL 1285
4" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 Fastite Gasket

UL 1285
4" - 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 Field LOK

UL 1285
4" - 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 FIELD LOK 350®

UL 1285
4" - 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 Flange Tyte

UL 1285
4" - 64"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 Fluid Tite

UL 1285
>= 4"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 Full Face Flange Tyte

UL 1285
4" - 64"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 IPS 2241 Rieber

UL 1285
1 1/2" - 18"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 IPS 2241 Super Rieber

UL 1285
14" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 IPS Biax Mambo

UL 1285
3" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 IPS Hero

UL 1285
1 1/2" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 Metric Pressure

UL 1285
50 mm - 630 mm

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 Metric Tyton

UL 1285
80 mm - 1200 mm

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 MJ Field Lok

UL 1285
4" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 One Piece Retainer Ring CIOD

UL 1285
4" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 PIP DD

UL 1285
10" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 PR IPS

UL 1285
6" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 Rest MJ (PVC)

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 Rieber IPS

UL 1285
1 1/2" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 S-Ring

UL 1285
6" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 Sure Stop

UL 1285
4" - 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 TURNER BIAX C909

UL 1285
4" - 16"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 TURNER C909 TYPE C

UL 1285
6" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 TURNER BIAX IPS

UL 1285
4" - 16"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 TURNER C909

UL 1285
4" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 Tyton

UL 1285
4" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 Tyton CM

UL 1285
3"- 42"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 Yellowmine

UL 1285
>= 4"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 LOKX System DIPS

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

NBR

NBR HT4537 LOKX System IPS

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Rieberlok Gasket

UL 1285
4" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 RCT Flex Tite C900

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 RCT Flex Tite IPS Transition

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 A/T IPS Gasket

UL 1285
1.5" - 4"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 C900 CIOD DD SBR Gasket

UL 1285
4" - 18"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 C900 Rieber Gasket

UL 1285
2" - 16"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 C900 Super Rieber Patented Gasket

UL 1285
2" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 C905 Super Rieber Patented Gasket

UL 1285
14" - 48"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 C909 Biax Mambo Gasket

UL 1285
4" - 16"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 CIOD Hero

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 CIOD RIEBER HR

UL 1285
14" 16" 18" 20"
30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Fast Grip

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Fastite Gasket

UL 1285
4" - 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 FIELD LOK 350®

UL 1285
4" - 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Field LOK SBR Gasket

UL 1285
4" - 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 LOKX System DIPS

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 LOKX System IPS

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Flange Tyte Gasket

UL 1285
4" - 64"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Flo Control IPS Gasket

UL 1285
2.5" - 8"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Full Face Flange Tyte

UL 1285
4" - 64"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 IPS 2241 Rieber Gasket

UL 1285
1.5" - 18"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 IPS 2241 Super Rieber Gasket

UL 1285
14" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 IPS Biax Mambo Gasket

UL 1285
3" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 IPS Hero

UL 1285
1.5" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Lock Push On Gasket

UL 1285
4" - 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 MJ Field Lok Gasket

UL 1285
4" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 One-Piece Retainer Ring CIOD Gasket

UL 1285
4" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 PIP DD SBR Gasket

UL 1285
10" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Plastic Retainer Ring IPS Gasket

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Platinum Press SBR Ozone | Gasket

UL 1285
63mm - 225mm

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Push-On Gasket

UL 1285
3" - 42"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Push-On Metric Gasket

UL 1285
80mm - 1200mm

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 RCT

UL 1285
4" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Rest MJ (PVC)

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Rieber CIOD Gasket

UL 1285
4" - 48"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Rieber IPS Gasket

UL 1285
1.5" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Rieber Metric Pressure Gasket

UL 1285
50mm - 630mm

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Rieber Metric Pressure Platinum Gkt

UL 1285
50mm - 1200mm

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 S-Ring

UL 1285
6" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Self Lock Push-On Gasket

UL 1285
3" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Sewer Ret/ Ring

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Super Bell Tite Gasket

UL 1285
4" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Sure Stop Gasket

UL 1285
4" - 36"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 THAI Gasket

UL 1285
100mm - 400mm

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Turner C909

UL 1285
4" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 TURNER C909 TYPE C

UL 1285
6" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Turner Lock

UL 1285
4" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Tyton Gasket

UL 1285
3" - 64"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 VF Sewer

UL 1285
4" - 8"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Turner Biax C909

UL 1285
4" - 16"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Turner Biax IPS

UL 1285
4" - 16"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Hydrogrip CIOD

UL 1285
4" - 30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Hydrogrip IPS

UL 1285
4" - 30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

SBR

SBR HT627 Hydrogrip AG

UL 1285
4" - 30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 Hydrogrip CIOD

UL 1285
4" - 30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 Hydrogrip IPS

UL 1285
4" - 30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.

Gaskets+ [1]

EPDM

EPDM HT553 Hydrogrip AG

UL 1285
4" - 30"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285.



 
Safelink Systems, Inc. DBA MrPEX Systems 
14799 Jackal Street NW
Suite 100 
Ramsey, MN 55303 
United States 
800-716-3406 
952-652-2472
Visit this company's website

Facility : # 1

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing^ § **

PEX

Mr Pex® Potable

ASTM E84
1/2", 3/4"

^ Flame Spread Index <= 25, Smoke Developed Index <= 50
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].



 
Sanbec Canada Inc 
1005 Berlier Street
Laval, QC H7L 3Z1 
Canada 
450-688-7467

Facility : Pex factory 1

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing# $ * [1] [2]

PEX

PLUMSOURCE

ASTM E84
3/8", 1/2" - 2"

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] ASTM E84, 1/2" - 2" The Flame Spread Index and Smoke Developed Index for 1/2" - 2"
    tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi
    performance fiberglass insulation as per RIFENG installation instructions. The 3/8"
    tubing is not insulated.
[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50

Tubing$ & [2] [3]

PEX

PLUMSOURCE

CAN/ULC S102.2
3/8", 1/2" - 2"

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]
[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[3] 3/8" Tubing (without insulation)
    Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
    1/2" through 2" Tubing (with insulation)
    Flame Spread Rating and Smoke Developed Classification based on when the tubing is field
    insulated with JM Microlok HP Hi Performance
    Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing
    shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[4] [5]

PEX

PLUMSOURCE

ASTM E84
3/8" - 2"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] Certified for red and white PEX 5106 monowall pipe.
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].

Tubing[4] [6]

PEX

PLUMSOURCE

CAN/ULC S102.2
3/8" - 2"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] Certified for red and white PEX 5106 monowall pipe.
[6]  The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].

Tubing[7] [8]

PEX

PLUMSOURCE

ASTM E84
3/8" - 1"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[7]  Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[8] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions (all listed construction/color/size combinations greater than
    or equal to 3/8" in diameter). Flame Spread Index and Smoke Developed Index based on
    minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM
    E84 FS<=25/SD<=50].

Tubing[7] [9]

PEX

PLUMSOURCE

CAN/ULC S102.2
3/8" - 1"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[7]  Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[9] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions (all listed construction/color/size
    combinations greater than or equal to 3/8" in diameter). Tubing shall be Marked
    [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[5] [10]

PEX

PLUMSOURCE

ASTM E84
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[10] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[6] [10]

PEX

PLUMSOURCE

CAN/ULC S102.2
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[6]  The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[10] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[5] [11]

PEX

PLUMSOURCE

ASTM E84
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[11] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.  
     Certified for red,  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
     sizes only. 

Tubing[6] [11]

PEX

PLUMSOURCE

CAN/ULC S102.2
1/8" - 3"[2]

[2] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[6]  The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[11] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.  
     Certified for red,  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
     sizes only. 



 
Sanderson Pipe Corporation 
875 International Boulevard
Clarksville, TN 37040 
United States 
904-275-2833

Facility : # 2 USA

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe

PVC

S.P.C.N.

UL 1285
PC 165: 4", 6", 8", 10", 12", 14", 16", 18", 20", 24" DR 25
PC 200: 14", 16", 18", 20", 24" DR 21
PC 235: 4", 6", 8", 10", 12", 14", 16", 18", 20", 24" DR 18
PC 305: 4", 6", 8", 10", 12", 14", 16", 18", 20", 24" DR 14


Facility : Pittsburg, KS

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe

PVC

S.P.C.K

UL 1285
PC 165: 4", 6", 8", 10", 12" DR 25
PC 235: 4", 6", 8", 10", 12" DR 18
PC 305: 4", 6", 8", 10", 12" DR 14



 
Teel Plastics Inc. 
1060 Teel Court
Baraboo, WI 53913 
United States 
608-355-3080
Visit this company's website

Facility : Baraboo, WI

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Pipe* +

PE 4710

Teel Plastics PE4710 Pressure Pipe

FM 1613
IPS 2", 3", 4", & 6" (PC 250) DR 9
IPS 2", 3", 4", & 6" (PC 200) DR 11

* Products comply with requirements of NFPA 24 Standard for the Installation of Private
  Fire Service Mains and Their Appurtenances.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.



 
The Boys, LLC dba SupplyHouse.com 
130 Spagnoli Road
Melville, NY 11747 
United States 
631-393-2855

Facility : # 1 China

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing# $ *

PEX

Bluefin

ASTM E84

3/8", 1/2" - 2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].

Tubing$ &

PEX

Bluefin

CAN/ULC S102.2

3/8", 1/2" - 2"
Flame Spread Rating <= 25 Smoke Developed Classification <= 50

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD
  <=50].
  1/2" - 2" tubing (with insulation), Flame Spread Index and Smoke Developed Index
  based on when the tubing is field insulated with JM Microlok HP Hi Performance
  Fiberglass insulation as per the pipe manufacturer's installation instructions.
  Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].



 
The Mosack Group, Inc. 
701 Matthews-Mint Hill Road
Matthews, NC 28105 
United States 
704-847-9191

Facility : Foshan, China

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing# $ * ^ § +++ [G]

PEX

Apollo/TMG/PurePEX/PureLink

ASTM E84

3/8", 1/2" - 2"[1]
WPPW2012 WPPW2034 WPPB2034 WPPR2012
WPPW201 WPPB2012 WPPR2034

68PXB100012 1/2"
Flame Spread Index <= 25 Flame Spread Index <= 25

68PXB100038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB1001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB10012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB10034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB10038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB1012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB1034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB201 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB2012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB2034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB3001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB30012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB30034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB5001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB50012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB50034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB50038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR100012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR100038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR1001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR10012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR10034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR10038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR1012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR1034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR201 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR2012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR2034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR3001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR30012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR30034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR5001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR50012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR50034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR50038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW100012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW100038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW1001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW10012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW10034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW10038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW1012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW1034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW201 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW2012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW2034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW3001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW30012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW30034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW5001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW50012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW50034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW50038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB1001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB10012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB10034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB101 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB1210 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB201 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB2012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB2034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB212 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB234 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB30012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB30034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB3410 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB50012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB50034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB512 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB534 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR1001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR10012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR10034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR101 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR1210 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR201 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR2012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR2034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR212 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR234 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR30012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR30034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR3410 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR50012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR50034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR512 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR534 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW1001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW10012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW10034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW101 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW1012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW1034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW1038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW201 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW2012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW2034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW212 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW234 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW2512 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW2534 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW30012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW30034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW50012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW50034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW5012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW5034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW51 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW512 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW534 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW538 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Tubing$ & § +++ [G]

PEX

Apollo/TMG/PurePEX/PureLink

CAN/ULC S102.2

3/8", 1/2" - 2"[1]
WPPR2034 WPPW2012 WPPR2012 WPPB2034
WPPW201 WPPB2012 WPPW2034

68PXB100012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB100038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB1001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB10012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB10034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB10038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB1012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB1034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB201 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB2012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB2034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB3001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB30012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB30034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB5001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB50012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB50034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXB50038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR100012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR100038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR1001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR10012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR10034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR10038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR1012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR1034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR201 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR2012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR2034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR3001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR30012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR30034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR5001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR50012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR50034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXR50038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW100012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW100038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW1001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW10012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW10034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW10038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW1012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW1034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW201 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW2012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW2034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW3001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW30012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW30034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW5001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW50012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW50034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

68PXW50038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB1001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB10012 1/2"
Flame Spread Rating <= 25 Smoke Developed Classification <= 50

APPB10034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB101 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB1210 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB201 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB2012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB2034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB212 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB234 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB30012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB30034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB3410 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB50012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB50034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB512 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPB534 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR1001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR10012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR10034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR101 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR1210 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR201 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR2012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR2034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR212 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR234 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR30012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR30034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR3410 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR50012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR50034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR512 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPR534 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW1001 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW10012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW10034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW101 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW1012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW1034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW1038 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW201 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW2012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW2034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW212 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW234 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW2512 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW2534 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW30012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW30034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW50012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW50034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW5012 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW5034 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW51 1"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW512 1/2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW534 3/4"
Flame Spread Index <= 25 Smoke Developed Index <= 50

APPW538 3/8"
Flame Spread Index <= 25 Smoke Developed Index <= 50

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.



 
The Mosack Group, Inc. 
11210 Allen Station Drive
Mint Hill, NC 28227 
United States 
888-229-2874

Facility : Mint Hill, NC

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing^ § **

PEX

Apollo

ASTM E84
1/2", 3/4"

^ Flame Spread Index <= 25, Smoke Developed Index <=50
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].


Facility : Calgary, Alberta, Canada

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing^ § **

PEX

Apollo

ASTM E84
1/2", 3/4"

^ Flame Spread Index <= 25, Smoke Developed Index <=50
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
   between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].



 
Top Shelf Manufacturing, Inc. 
800 Bronze Road NE
Warren, OH 44483 
United States 
844 974 2400

Facility : #1 China

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing# $ * [1] [2]

PEX

TruuFlo PEX-B

ASTM E84
3/8", 1/2" - 2"

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[2] ASTM E84, 1/2" - 2" The Flame Spread Index and Smoke Developed Index for 1/2" - 2"
    tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi
    performance fiberglass insulation as per RIFENG installation instructions. The 3/8"
    tubing is not insulated.

Tubing$ & [1] [3]

PEX

TruuFlo PEX-B

CAN/ULC S102.2
3/8", 1/2" - 2"

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation), Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[3] 3/8" Tubing (without insulation)
    Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
    1/2" through 2" Tubing (with insulation)
    Flame Spread Rating and Smoke Developed Classification based on when the tubing is field
    insulated with JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].

Tubing[4] [5]

PEX

TruuFlo PEX-B

ASTM E84
3/8" - 2"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] Certified for red and white PEX 5106 monowall pipe.
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].

Tubing[4] [6]

PEX

TruuFlo PEX-B

CAN/ULC S102.2
3/8" - 2"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] Certified for red and white PEX 5106 monowall pipe.
[6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].

Tubing[7] [8]

PEX

TruuFlo PEX-B

ASTM E84
3/8" - 1"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[7] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[8] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance   fiberglass insulation as per RIFENG
    installation instructions (all listed construction/color/size combinations greater than
    or equal to 3/8" in diameter). Flame Spread Index and Smoke Developed Index based on
    minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM
    E84 FS<=25/SD<=50].

Tubing[7] [9]

PEX

TruuFlo PEX-B

CAN/ULC S102.2
3/8" - 1"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[7] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[9] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions (all listed construction/color/size
    combinations greater than or equal to 3/8" in diameter). Tubing shall be Marked
    [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[5] [10]

PEX

TruuFlo PEX-A

ASTM E84
1/8" - 3"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[10] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. 
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[6] [10]

PEX

TruuFlo PEX-A

CAN/ULC S102.2
1/8" - 3"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[10] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. 
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[5] [11]

PEX

TruuFlo PEX-A

ASTM E84
1/8" - 3"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[11] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
     Certified for red, white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
     sizes only.  

Tubing[6] [11]

PEX

TruuFlo PEX-A

CAN/ULC S102.2
1/8" - 3"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[11] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
     Certified for red, white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
     sizes only.  



 
Topaipe Plumbing LLC 
3413 Devonshire Ct
Flower Mound, TX 75022 
United States 
945-270-9776

Facility : Guangdong, China

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing[1] [3]

PEX

TOPAIPE

ASTM E84
3/8" - 2"[2]

[2] Flame Spread Index <= 25	
    Smoke Developed Index <= 50
[1] Certified for red and white PEX 5106 monowall pipe.
[3] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].

Tubing[1] [4]

PEX

TOPAIPE

CAN/ULC S102.2
3/8" - 2"[2]

[2] Flame Spread Index <= 25	
    Smoke Developed Index <= 50
[1] Certified for red and white PEX 5106 monowall pipe.
[4] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the
    pipe	manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc
    S102.2	 FS<=25/SD<=50].

Tubing[5] [6]

PEX

TOPAIPE

ASTM E84
3/8" - 1"[2]

[2] Flame Spread Index <= 25	
    Smoke Developed Index <= 50
[5] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[6] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance   fiberglass insulation as per RIFENG
    installation instructions (all listed construction/color/size combinations greater
    than	or equal to 3/8" in diameter). Flame Spread Index and Smoke Developed Index based
    on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs
    ASTM E84 FS<=25/SD<=50].

Tubing[5] [7]

PEX

TOPAIPE

CAN/ULC S102.2
3/8" - 1"[2]

[2] Flame Spread Index <= 25	
    Smoke Developed Index <= 50
[5] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[7] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the
    pipe	manufacturer's installation instructions (all listed construction/color/size
    combinations greater than or equal to 3/8" in diameter). Tubing shall be Marked
    [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[3] [8]

PEX

TOPAIPE PEXa

ASTM E84
1/8" - 3"[2]

[2] Flame Spread Index <= 25	
    Smoke Developed Index <= 50
[3] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[8] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
    red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red, 
    white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.

Tubing[4] [8]

PEX

TOPAIPE PEXa

CAN/ULC S102.2
1/8" - 3"[2]

[2] Flame Spread Index <= 25	
    Smoke Developed Index <= 50
[4] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the
    pipe	manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc
    S102.2	 FS<=25/SD<=50].
[8] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
    red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red, 
    white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.



 
Trelleborg Pipe Seals Tijuana S.A de C.V 
Colina No. 11850, Parque
Industrial el Florido, Sección Colinas 
Tijuana, BC 22237 
Mexico 
52 664 625 4885

Facility : Tijuana, Baja California, Mexico

Fire Main - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Gasket/Sealing Materials+ ~

SBR

T-565 RIEBER C-900 SBR

FM 1612
4" - 48"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

SBR

T-559 RIEBER PRESSURE METRIC SBR

FM 1612
450 mm - 1200 mm

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

SBR

T-560 RIEBER IPS SBR

FM 1612
1-1/2" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

SBR

MP 148 T-559 RIEBER PRESSURE METRIC SBR

FM 1612
450" - 1200"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

SBR

MP 148 T-560 RIEBER IPS SBR

FM 1612
1-1/2" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

SBR

MP 148 T-565 RIEBER C-900 SBR

FM 1612
4" - 48"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

SBR

CERTA-LOK O-RING SBR

FM 1612
5" - 48"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

NBR

T-560 RIEBER IPS NITRILE

FM 1612
1 1/2 - 24 in

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

NBR

T-565 RIEBER C-900 NITRILE

FM 1612
4" - 48"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

NBR

NR 648 T-560 RIEBER IPS NITRILE

FM 1612
1-1/2" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

NBR

NR 648 T-565 RIEBER C-900 NITRILE

FM 1612
4" - 48"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

NBR

CERTA-LOK O-RING NITRILE

FM 1612
2" - 10"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

NBR

FLUID-TITE NITRILE CIOD

FM 1612
6" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

EPDM

T-560 RIEBER IPS EPDM

FM 1612
1-1/2" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

EPDM

T-565 RIEBER C-900 EPDM

FM 1612
4" - 48"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

EPDM

T-584 ANGER LOCK EPDM

FM 1612
4" - 48"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

EPDM

T-552 ANGER LOCK IPS EPDM

FM 1612
2"-14"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

EPDM

T-603 POWER LOCK IPS EPDM

FM 1612
1-1/2" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

EPDM

E 148 T-560 RIEBER IPS EPDM

FM 1612
1-1/2" - 24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

EPDM

E 148 T-565 RIEBER C-900 EPDM

FM 1612
4" - 48"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

EPDM

E 148 T-552 ANGER LOCK IPS EPDM

FM 1612
2"-14"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

EPDM

E 148 T-584 ANGER LOCK EPDM

FM 1612
4" - 48"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

EPDM

E 148 T-603 POWER LOCK IPS EPDM

FM 1612
1-1/2" - 12"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

EPDM

CERTA-LOK O-RING EPDM

FM 1612
2"-10"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.

Gasket/Sealing Materials+ ~

EPDM

FLUID-TITE EPDM CIOD

FM 1612
6"-24"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
~  Use of this material in NSF Certified pipe requires NSF's prior authorization.



 
Uponor 
5925 148th Street West
Apple Valley, MN 55124 
United States 
800-321-4739 
952-891-2000
Visit this company's website

Facility : Apple Valley, MN

Fire Sprinkler Pipe and Fitting Systems

Product Type Material Type Trade Name Product Standard

Pipe and Fitting System% ¢ **

MLTPL

AQUASAFE®*

ANSI/CAN/UL 1821

Coupling
LF4545075 - ProPEX LF Brass Coupling, 1/2" PEX x 3/4" PEX LF4547510 - ProPEX LF Brass Coupling, 3/4" PEX x 1" PEX LF4547575 - ProPEX LF Brass Coupling, 3/4" PEX x 3/4" PEX LF4541010 - ProPEX LF Brass Coupling, 1" PEX x 1" PEX
Q4777510/Q4777510R5 - ProPEX EP Coupling, 3/4" PEX x 1" PEX Q4777575/Q47775R5/Q47775R20 - ProPEX EP Coupling, 3/4" PEX x 3/4" PEX Q4771010/Q47710R5 - ProPEX EP Coupling, 1" PEX x 1" PEX Q4771307 - ProPEX EP Coupling, 1 1/4" PEX x 3/4" PEX
Q4771310 - ProPEX EP Coupling, 1 1/4" PEX x 1" PEX Q4771313 - ProPEX EP Coupling, 1 1/4" PEX x 1 1/4" PEX

Elbow
LF4710500 - ProPEX LF Brass Elbow, 1/2" PEX x 1/2" PEX LF4710750 - ProPEX LF Brass Elbow, 3/4" PEX x 3/4" PEX LF4711000 - ProPEX LF Brass Elbow, 1" PEX x 1" PEX Q4760500/Q4760500R5/Q4760500R25 - ProPEX EP Elbow, 1/2" PEX x 1/2" PEX
Q4760750/Q4760750R5/Q4760750R10 - ProPEX EP Elbow, 3/4" PEX x 3/4" PEX Q4761000/Q4761000R5 - ProPEX EP Elbow, 1" PEX x 1" PEX Q4761250 - ProPEX EP Elbow, 1 1/4" PEX x 1 1/4" PEX Q4761515 - ProPEX 45 degree EP Elbow, 1-1/2" x 1-1/2"
Q4762020 - ProPEX 45 degree EP Elbow, 2" x 2"

Female Adapter
LF4577575 - ProPEX LF Brass Female Threaded Adapter, 3/4" PEX x 3/4" NPT LF4571010/LF45710R - ProPEX LF Brass Female Threaded Adapter, 1" PEX x 1" NPT LF4571313 - ProPEX LF Brass Female Threaded Adapter, 1 1/4" PEX x 1 1/4" NPT LF4571515 - ProPEX LF Brass Female Threaded Adapter, 1 1/2" PEX x 1 1/2" NPT
LF4572020 - ProPEX LF Brass Female Threaded Adapter, 2" PEX x 2" NPT

Fire Sprinkler Head Adapter
LF7707575 - ProPEX LF Brass Fire Sprinkler Adapter Tee,¾" PEX x ¾" PEX x ½" FNPT LF7701010 - ProPEX LF Brass Fire Sprinkler Adapter Tee,1" PEX x 1" PEX x ½: FNPT LF7717550 - ProPEX LF Brass Fire Sprinkler Adapter Elbow, 3/4" PEX x 1/2" FNPT LF7711050 - ProPEX LF Brass Fire Sprinkler Adapter Elbow, 1" PEX x 1/2" FNPT

Male Adapter
LF4527575/LF45275R - ProPEX LF Brass Male Threaded Adapter, 3/4" PEX x 3/4" NPT LF4521010/LF45210R - ProPEX LF Brass Male Threaded Adapter, 1" PEX x 1" NPT LF4521313 - ProPEX LF Brass Male Threaded Adapter, 1 1/4" PEX x 1 1/4" NPT

Opposing Port Tees
Q4801075 - ProPEX EP Opposing Port Tee, 1" PEXx1" PEXx3/4"PEXx3/4" PEX Q4801375 - ProPEX EP Opposing Port Tee, 1 1/4" PEXx1 1/4" PEXx3/4" PEXx3/4" PEX Q4801575 - ProPEX EP Opposing Port Tee-1 1/2" PEXx1 1/2" PEXx3/4" PEXx3/4" PEX Q4802075 - ProPEX EP Opposing Port Tee-2" PEXx2" PEXx3/4"PEXx3/4" PEX

Plug
Q4350750/Q4350750R5 - ProPEX EP Plug, 3/4" PEX Q4351000/Q4351000R5 - ProPEX EP Plug , 1" PEX Q4351250 - ProPEX EP Plug, 1 1/4"

ProPEX Rings
Q4690756/Q4690756R10/Q4690756R30 - 3/4" ProPEX Ring with Stop Q4690756PF - 3/4" ProPEX Ring with Stop, Blue Print Q4691000/Q4691000R10 - 1" ProPEX Ring with Stop Q4691000PF - 1" ProPEX Ring with Stop, Blue Print
Q4691250 - 1 1/4" ProPEX Ring with Stop Q4691250PF - 1 1/4" ProPEX Ring with Stop, Blue Print

Reducing Tee
LF4707550 - ProPEX LF Brass Tee, 3/4" PEX x 3/4" PEX x 1/2" PEX LF4707710 - ProPEX LF Brass Tee, 3/4" PEX x 3/4" PEX x 1" PEX LF4701150 - ProPEX LF Brass Tee, 1" PEX x 1" PEX x 1/2" PEX LF4701175 - ProPEX LF Brass Tee, 1" PEX x 1" PEX x 3/4" PEX
LF4701751 - ProPEX LF Brass Tee, 1" PEX x 3/4" PEX x 1" PEX LF4701775 - ProPEX LF Brass Tee, 1" PEX x 3/4" PEX x 3/4" PEX Q4757550/Q4757550R5 - ProPEX EP Reducing Tee, 3/4" PEX x 3/4" PEX x 1/2" PEX Q4757557 - ProPEX EP Reducing Tee, 3/4" PEX x 1/2" PEX x 3/4" PEX
Q4757557R8 - ProPEX EP Reducing Tee, 3/4" PEX x 1/2" PEX x 3/4" PEX - copy Q4757557 - ProPEX EP Reducing Tee, 3/4" PEX x 1/2" PEX x 3/4" PEX - copy Q4757710 - ProPEX EP Reducing Tee, 3/4" PEX x 3/4" PEX x 1" PEX Q4751113 - ProPEX EP Reducing Tee, 1" PEX x 1" PEX x 1 1/4"
Q4751150 - ProPEX EP Reducing Tee, 1" PEX x 1" PEX x 1/2" PEX Q4751175/Q4751175R5 - ProPEX EP Reducing Tee, 1" PEX x 1" PEX x 3/4" PEX Q4751311 - ProPEX EP Reducing Tee, 1 1/4" PEX x 1" PEX x 3/4" PEX Q4751317 - ProPEX EP Reducing Tee, 1 1/4" PEX x 1" PEX x 1" PEX
Q4751331 - ProPEX EP Reducing Tee, 1 1/4" PEX x 1 1/4" PEX x 1" PEX Q4751337 - ProPEX EP Reducing Tee, 1 1/4" PEX x 1 1/4" PEX x 3/4" PEX Q4751371 - ProPEX EP Reducing Tee, 1 1/4" PEX x 3/4" PEX x 1" PEX Q4751373 - ProPEX EP Reducing Tee, 1 1/4" PEX x 3/4" PEX x 1 1/4" PEX
Q4751377 - ProPEX EP Reducing Tee, 1 1/4" PEX x 3/4" PEX x 3/4" PEX Q4751511 - ProPEX EP Reducing Tee, 1 1/2" PEX x 1" PEX x 1" PEX Q4751517 - ProPEX EP Reducing Tee, 1 1/2" PEX x 1" PEX x 3/4" PEX Q4751551 - ProPEX EP Reducing Tee, 1 1/2" PEX x 1 1/2" PEX x 3/4" PEX
Q4751553 - ProPEX EP Reducing Tee, 1 1/2" PEX x 1 1/2" PEX x 1 1/4" PEX Q4751557 - ProPEX EP Reducing Tee, 1 1/2" PEX x 1 1/2" PEX x 1" PEX Q4751751/Q4751751R5 - ProPEX EP Reducing Tee, 1" PEX x 3/4" PEX x 1" PEX Q4751775 - ProPEX EP Reducing Tee, 1" PEX x 3/4" PEX x 3/4" PEX
Q47515501 - ProPEX EP Reducing Tee, 1/2" x 1-1/2" x 1/2" Q4751350 - ProPEX EP Reducing Tee, 1-1/4" x 1-1/4" x 1/2" Q4751505 - ProPEX EP Reducing Tee, 1-1/2"  x 1"  x 1-1/2" Q4752152 - ProPEX EP Reducing Tee, 2" x 1-1/2" x 2"
Q4752250 - ProPEX EP Reducing Tee, 2" x 2" x 1/2"

Sweat Adapter
LF4517575/LF45175R - ProPEX LF Brass Sweat Adapter, 3/4" PEX x 3/4" Copper LF4511010/LF45110R - ProPEX LF Brass Sweat Adapter 1" PEX x 1" Copper LF4511313 - ProPEX LF Brass Sweat Adapter, 1 1/4" PEX x 1 1/4" Copper LF4511515 - ProPEX LF Brass Sweat Adapter, 1 1/2" PEX x 1 1/2" Copper
LF4512020 - ProPEX LF Brass Sweat Adapter, 2" PEX x 2" Copper

Tee
LF4707575 - ProPEX LF Brass Tee, 3/4" PEX x 3/4" PEX x 3/4" PEX LF4701010 - ProPEX LF Brass Tee, 1" PEX x 1" PEX x 1" PEX Q4757575/Q4757575R5 - ProPEX EP Tee, 3/4" PEX x 3/4" PEX x 3/4" PEX Q4751010 - ProPEX EP Tee, 1" PEX x 1" PEX x 1" PEX
Q4751313 - ProPEX EP Tee, 1 1/4" PEX x 1 1/4" PEX x 1 1/4" PEX WS4360751/SWP4360751 - ProPEX EP Elbow Water Meter Connector, 3/4" PEX x 1" NPSM WS4361001 - ProPEX EP Elbow Water Meter Connector, 1" PEX x 1 1/4" NPSM WS4360750/SWP4360750- ProPEX EP Straight Water Meter Connector, 3/4" PEXx1" NPSM
WS4360750R - ProPEX EP Straight Water Meter Connector, 3/4" PEXx1" NPSM WS4361000 - ProPEX EP Straight Water Meter Connector, 1" PEX x 1 1/4" NPSM

Tubing
3/4" Uponor AquaPEX White 1" Uponor AquaPEX White 1 1/4" Uponor AquaPEX White

% PEX pipe and fittings are intended for use in multi-purpose piping systems of
  residential occupancies as defined in ANSI/NFPA 13D, "Installation of Sprinkler Systems
  in One- and Two- Family Dwellings and Manufactured Homes", the National Building Code of
  Canada, and the International Residential Code, Section 2904, and are designed to
  withstand a working pressure of not less than 130 psi at 120° F.  PEX pipe and fittings
  are intended to be installed in accordance with the requirements specified in the
  manufacturer’s installation instructions and ANSI/NFPA 13D. Protection is intended to be
  provided for PEX pipe and fittings in multi-purpose piping systems.  The minimum
  protection should consist of either (1) one layer of 3/8-in. gypsum wallboard, (2) a
  suspended membrane ceiling with lay-in panels or tiles having a weight of not less than
  0.35 lbs per sq ft when installed with metallic support grids, (3) 1/2 in plywood or (4)
  other material with a 15 minute fire rating. PEX pipe and fittings are intended for use
  in areas where the maximum ambient temperature does not exceed 120° F. These pipe and
  fittings are not intended to be installed in outdoor applications. The PEX pipe and
  fittings are intendedfor use in wet-pipe systems only and have not been evaluated for
  use in dry-pipe systems.
* These products may also be represented by the trade name AquaPEX.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
** Pipe and fittings Certified as a system using installation and design manual titled
   "Uponor Residential Fire Sprinkler Systems, AquaSAFE™ System Installation Guide".


Facility : Hutchinson, MN

Fire Sprinkler Pipe and Fitting Systems

Product Type Material Type Trade Name Product Standard

Pipe and Fitting System% ¢ **

PEX

AQUASAFE®*

ANSI/CAN/UL 1821

Tubing
3/4" Uponor AquaPEX White 1" Uponor AquaPEX White

% PEX pipe and fittings are intended for use in multi-purpose piping systems of
  residential occupancies as defined in ANSI/NFPA 13D, "Installation of Sprinkler Systems
  in One- and Two- Family Dwellings and Manufactured Homes", the National Building Code of
  Canada, and the International Residential Code, Section 2904, and are designed to
  withstand a working pressure of not less than 130 psi at 120° F.  PEX pipe and fittings
  are intended to be installed in accordance with the requirements specified in the
  manufacturer’s installation instructions and ANSI/NFPA 13D. Protection is intended to be
  provided for PEX pipe and fittings in multi-purpose piping systems. The minimum
  protection should consist of either (1) one layer of 3/8-in. gypsum wallboard, (2) a
  suspended membrane ceiling with lay-in panels or tiles having a weight of not less than
  0.35 lbs per sq ft when installed with metallic support grids, (3) 1/2 in plywood or (4)
  other material with a 15 minute fire rating.  PEX pipe and fittings are intended for use
  in areas where the maximum ambient temperature does not exceed 120° F.  These pipe and
  fittings are not intended to be installed in outdoor applications.  The PEX pipe and
  fittings are intended for use in wet-pipe systems only and have not been evaluated for
  use in drypipe systems.
* These products may also be represented by the trade name AquaPEX.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
** Pipe and fittings Certified as a system using installation and design manual titled
   "Uponor Residential Fire Sprinkler Systems, AquaSAFE™ System Installation Guide".



 
Waterline Products Co. Limited 
100 Westcreek Blvd, Unit 2
Brampton, ON L6T 5V7 
Canada 
+1 905 453 2400

Facility : # 1 China

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing$ &

PEX

Waterline PEX

CAN/ULC S102.2

3/8", 1/2" - 2"
Flame Spread Rating <= 25 Smoke Developed Classification <= 50

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation), Flame Spread Index and Smoke Developed Index
  based on when the tubing is field insulated with JM Microlok HP Hi Performance
  Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing
  shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing# $ *

PEX

Waterline PEX

ASTM E84

3/8", 1/2" - 2"
Flame Spread Index <= 25 Smoke Developed Index <= 50

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].



 
Western Led Lighting Corp. 
2020 32 Avenue NE, Unit: E
Calgary 
AB T2E 9A7 
Canada 
1 4037001001

Facility : # 1 China

Surface Burning Characteristics of Building Materials

Product Type Material Type Trade Name Product Standard

Tubing# $ * [1] [2]

PEX

AGUA BAY PEX-B

ASTM E84
3/8", 1/2" - 2"

# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[2] ASTM E84, 1/2" - 2" The Flame Spread Index and Smoke Developed Index for 1/2" - 2"
    tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi
    performance fiberglass insulation as per RIFENG installation instructions. The 3/8"
    tubing is not insulated.

Tubing$ & [1] [3]

PEX

AGUA BAY PEX-B

CAN/ULC S102.2
3/8", 1/2" - 2"

$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[3] 3/8" Tubing (without insulation)
    Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
    1/2" through 2" Tubing (with insulation)
    Flame Spread Rating and Smoke Developed Classification based on when the tubing is field
    insulated with JM Microlok HP Hi Performance
    Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing
    shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[4] [5]

PEX

AGUA BAY PEX-B

ASTM E84
3/8" - 2"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] Certified for red and white PEX 5106 monowall pipe.
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].

Tubing[4] [6]

PEX

AGUA BAY PEX-B

CAN/ULC S102.2
3/8" - 2"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[4] Certified for red and white PEX 5106 monowall pipe.
[6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].

Tubing[7] [8]

PEX

AGUA BAY PEX-B

ASTM E84
3/8" - 1"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[7] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[8] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance	fiberglass insulation as per RIFENG
    installation instructions (all listed construction/color/size combinations greater than
    or equal to 3/8" in diameter). Flame Spread Index and Smoke Developed Index based on
    minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM
    E84 FS<=25/SD<=50].

Tubing[7] [9]

PEX

AGUA BAY PEX-B

CAN/ULC S102.2
3/8" - 1"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[7] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
    pipe.
[9] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions (all listed construction/color/size
    combinations greater than or equal to 3/8" in diameter). Tubing shall be Marked
    [cNSF®-fs ULc S102.2 FS<=25/SD<=50].

Tubing[5] [10]

PEX

AGUA BAY PEX-A

ASTM E84
1/8" - 3"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[10] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.		
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[6] [10]

PEX

AGUA BAY PEX-A

CAN/ULC S102.2
1/8" - 3"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[10] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.		
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only.

Tubing[5] [11]

PEX

AGUA BAY PEX-A

ASTM E84
1/8" - 3"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
    insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG
    installation instructions. Flame Spread Index and Smoke Developed Index based on minimum
    spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84
    FS<=25/SD<=50].
[11] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
     Certified for red,  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
     sizes only.  

Tubing[6] [11]

PEX

AGUA BAY PEX-A

CAN/ULC S102.2
1/8" - 3"[1]

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
[6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
    insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe
    manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2
    FS<=25/SD<=50].
[11] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.  
     Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. 
     Certified for red,  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
     sizes only.  



 
Zurn PEX, Inc. 
116 Maple Street
Commerce, TX 75428 
United States 
903-886-2580
Visit this company's website

Facility : Harborcreek, PA

Fire Sprinkler Pipe and Fitting Systems

Product Type Material Type Trade Name Product Standard

Pipe and Fitting System% ** [G]

MLTPL

Zurn PEX Fire Protection System

ANSI/CAN/UL 1821

Coupling (BARB x BARB)
1" barb x 1" barb (QQC55GFX) 1" barb x 1" barb (QQPC55FX) 1 1/4" barb x 1 1/4" barb (QQC66GFX) 1 1/2" barb x 1 1/2" barb (QQC77GFX)
2" barb x 2" barb (QQC88GFX)

Crimp Coupling
1" Crimp PEX X 1/2" FPT (QQFSC53GFX)

Crimp Tee
1" Crimp PEX x 1" Crimp PEX x 1/2" FPT (QQFST553GFX)

Elbow (BARB X BARB)
1" barb x 1" barb (QQPE55FX) 1" barb x 1" barb (QQE55GFX) 1 1/4" barb x 1 1/4" barb (QQE66GFX) 1 1/2" barb x 1 1/2" barb (QQE77GFX)
2" barb x 2" barb (QQE88GFX)

Expansion Coupling
1" EXP PEX x 1/2" FPT (QEFSC53GFX)

Expansion Tee
1" EXP PEX x 1" EXP PEX x 1/2" FPT (QEFST553FGX)

Female Adapter (BARB x FPT)
1" barb x 1" FPT (QQUFC55GFX) 1 1/4" barb x 1 1/4" FPT (QQUFC66GFX) 1 1/2" barb x 1 1/2" FPT (QQUFC77GFX)

Female Sweat Adapter (BARB x SWEAT)
1" barb x 1" sweat (QQ800CFX) 1 1/4" barb x 1 1/4" sweat (QQ812GFX) 1 1/2" barb x 1 1/2" sweat (QQ950GFX) 2" barb x 2" sweat (QQ1050GFX)

Fire Sprinkler Coupling
1" barb x 1/2" FPT (QQFSC53GFX)

Fire Sprinkler Tee (BARB X BARB X FPT)
1" barb x 1" barb x 1/2" FPT (QQFST553GFX)

Male Adapter (BARB X MPT)
1" barb x 1" MPT (QQMC55GFX) 1" barb x 1" barb MPT (QQPMC55FX) 1 1/4" barb x 1 1/4" MPT (QQMC66GFX) 1 1/2" barb x 1 1/2" MPT (QQMC77GFX)
2" barb x 2" MPT (QQMC88GFX)

Male Sweat Adapter (BARB X SWEAT)
1" barb x 1" sweat (QQ700CFX)

Plug (Barb)
1" (QQP5GFX) 1 1/4" (QQP6GFX) 1 1/2" (QQP7GFX) 2" (QQP8GFX)

Reducer Tee (BARB X BARB X BARB)
1" barb x 1" barb x 1/2" barb (QQT553GFX) 1" barb x 1" barb x 3/4" barb (QQT554GFX) 1" barb x 1" barb x 1/2" barb (QQPT553FX) 1" barb x 1" barb x 3/4" barb (QQPT554FX)
1 1/4" barb x 1 1/4" barb x 1/2" barb (QQT663GFX) 1 1/4" barb x 1 1/4" barb x 3/4" barb (QQT664GFX) 1 1/2" barb x 1 1/2" barb x 3/4" barb (QQT774GFX) 1 1/2" barb x 1 1/2" barb x 1" barb (QQT775GFX)
2" barb x 2" barb x 1" barb (QQT885GFX)

Reducing Coupling (BARB x BARB)
1" barb x 3/4" barb (QQPC54FX) 1 1/4" barb x 1" barb (QQC65GFX) 1 1/2" barb x 1 1/4" barb (QQC76GFX) 2" barb x 1 1/2" barb (QQC87GFX)

Tee (BARB X BARB X BARB)
1" barb x 1" barb x 1" barb (QQT555GFX) 1" barb x 1" barb x 1" barb (QQPT555GFX) 1 1/4" barb x 1 1/4" barb x 1 1/4" barb (QQT666GFX) 1 1/2" barb x 1 1/2" barb x 1 1/2" barb (QQT777GFX)
2" barb x 2" barb x 2" barb (QQT888GFX)

Tubing
1" – 2" White ZurnPEX

% PEX pipe and fittings are intended for use in multi-purpose piping systems of
  residential occupancies as defined in ANSI/NFPA 13D, "Installation of Sprinkler Systems
  in One- and Two- Family Dwellings and Manufactured Homes" and the International
  Residential Code, Section 2904, and are designed to withstand a working pressure of not
  less than 130 psi at 120° F.  PEX pipe and fittings are intended to be installed in
  accordance with the requirements specified in the manufacturer’s installation
  instructions and ANSI/NFPA 13D. Protection is intended to be provided for PEX pipe and
  fittings in multi-purpose piping systems.  The minimum protection should consist of
  either (1) one layer of 3/8-in. gypsum wallboard, (2) a suspended membrane ceiling with
  lay-in panels or tiles having a weight of not less than 0.35 lbs per sq ft when
  installed with metallic support grids, (3) 1/2 in plywood or (4) other material with a
  15 minute fire rating. PEX pipe and fittings are intended for use in areas where the
  maximum ambient temperature does not exceed 120° F. These pipe and fittings are not
  intended to be installed in outdoor applications. The PEX pipe and fittings are intended
  for use in wet-pipe systems only and have not been evaluated for use in dry-pipe systems.
** Pipe and fittings Certified as a system using Installation/assembly instructions titled
   "Zurn PEX Residential Fire Protection Addendum to Plumbing Installation Guide".
   
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


Facility : Commerce, TX

Fire Sprinkler Pipe and Fitting Systems

Product Type Material Type Trade Name Product Standard

Pipe and Fitting System% ** [G]

PEX

Zurn PEX Fire Protection System

ANSI/CAN/UL 1821

Tubing
1" White ZurnPEX

% PEX pipe and fittings are intended for use in multi-purpose piping systems of
  residential occupancies as defined in ANSI/NFPA 13D, "Installation of Sprinkler Systems
  in One- and Two- Family Dwellings and Manufactured Homes" and the International
  Residential Code, Section 2904, and are designed to withstand a working pressure of not
  less than 130 psi at 120° F.  PEX pipe and fittings are intended to be installed in
  accordance with the requirements specified in the manufacturer’s installation
  instructions and ANSI/NFPA 13D. Protection is intended to be provided for PEX pipe and
  fittings in multi-purpose piping systems.  The minimum protection should consist of
  either (1) one layer of 3/8-in. gypsum wallboard, (2) a suspended membrane ceiling with
  lay-in panels or tiles having a weight of not less than 0.35 lbs per sq ft when
  installed with metallic support grids, (3) 1/2 in plywood or (4) other material with a
  15 minute fire rating. PEX pipe and fittings are intended for use in areas where the
  maximum ambient temperature does not exceed 120° F. These pipe and fittings are not
  intended to be installed in outdoor applications. The PEX pipe and fittings are intended
  for use in wet-pipe systems only and have not been evaluated for use in dry-pipe systems.
** Pipe and fittings Certified as a system using Installation/assembly instructions titled
   "Zurn PEX Residential Fire Protection Addendum to Plumbing Installation Guide", dated
   October 2010.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


Number of matching Manufacturers is 46
Number of matching Products is 2775
Processing time was 0 seconds