NSF/ANSI 14
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
Atkore Plastic Pipe Corporation | |
16100 South Lanthrop Avenue | |
Harvey, IL 60426 | |
United States | |
708-225-2075 |
Facility : Tampa, FL
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe+ [G] |
PVC |
Heritage Plastics |
UL 1285 |
8" DR DR 14, DR 18, DR 25 | |||
6" DR DR 14, DR 18, DR 25 | |||
10" DR DR 14, DR 18, DR 25 | |||
4" DR DR 14, DR 18, DR 25 | |||
12" DR DR 14, DR 18, DR 25 | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Eugene, OR
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe+ [G] |
PVC |
Heritage Plastics |
UL 1285 |
4" DR 14, 18, 25 | |||
6" DR 14, 18, 25 | |||
8" DR 14, 18, 25 | |||
10" DR 14, 18, 25 | |||
12" DR 14, 18, 25 | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Bow Plumbing Group, Inc. | |
5700 Cote de Liesse | |
Montreal, QC H4T 1B1 | |
Canada | |
450-372-5481 | |
Visit this company's website |
Facility : # 2 Granby, Quebec, Canada
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing# [1] |
PEX |
Bowpex |
ASTM E84 |
1/2" (without insulation) | |||
# Certified Bowpex tubing is natural, red, blue or white. [1] Flame Spread Index <=25, Smoke Developed Index <=50. Flame Spread Index and Smoke Developed Index for ASTM E84 is based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2 FS25/SD50]. |
|||
Tubing# ¢ [2] |
PEX |
Bowpex |
CAN/ULC S102.2 |
1/2" (without insulation) | |||
# Certified Bowpex tubing is natural, red, blue or white. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [2] Flame Spread Value <=25, Smoke Developed Value <=50. Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2 FS25/SD50]. |
|||
Tubing# ¢ [3] |
PEX |
Bowpex |
CAN/ULC S102.2 |
1/8", 1/4", 3/8", 3/4", 1" (with insulation) | |||
# Certified Bowpex tubing is natural, red, blue or white. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [3] Flame Spread Value <=25, Smoke Developed Value <=50. The Flame Spread Value and Smoke Developed Value is based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per Bow installation instructions. Tubing shall be marked [cNSF®-fs ULCS102.2 FS25/SD50]. |
|||
Tubing$ [1] |
PE-RT 4710 |
Enviro EXP |
ASTM E84 |
1/2" (without insulation) | |||
$ Certified Enviro EXP is coextruded natural tubing with a red, blue, or clear outer layer. [1] Flame Spread Index <=25, Smoke Developed Index <=50. Flame Spread Index and Smoke Developed Index for ASTM E84 is based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2 FS25/SD50]. |
|||
Tubing$ ¢ [2] |
PE-RT 4710 |
Enviro EXP |
CAN/ULC S102.2 |
1/2" (without insulation) | |||
$ Certified Enviro EXP is coextruded natural tubing with a red, blue, or clear outer layer. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [2] Flame Spread Value <=25, Smoke Developed Value <=50. Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2 FS25/SD50]. |
|||
Tubing$ ¢ [3] |
PE-RT 4710 |
Enviro EXP |
CAN/ULC S102.2 |
3/4" (without insulation) | |||
$ Certified Enviro EXP is coextruded natural tubing with a red, blue, or clear outer layer. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [3] Flame Spread Value <=25, Smoke Developed Value <=50. The Flame Spread Value and Smoke Developed Value is based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per Bow installation instructions. Tubing shall be marked [cNSF®-fs ULCS102.2 FS25/SD50]. |
|||
Tubing% [1] |
PEX |
Oxypex |
ASTM E84 |
1/2" (without insulation) | |||
% Certified Oxypex tubing has a red outer layer. [1] Flame Spread Index <=25, Smoke Developed Index <=50. Flame Spread Index and Smoke Developed Index for ASTM E84 is based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2 FS25/SD50]. |
|||
Tubing% ¢ [2] |
PEX |
Oxypex |
CAN/ULC S102.2 |
1/2" (without insulation) | |||
% Certified Oxypex tubing has a red outer layer. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [2] Flame Spread Value <=25, Smoke Developed Value <=50. Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2 FS25/SD50]. |
|||
Tubing% ¢ [3] |
PEX |
Oxypex |
CAN/ULC S102.2 |
1/4", 3/8", 5/8", 3/4", 1" (with insulation) | |||
% Certified Oxypex tubing has a red outer layer. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [3] Flame Spread Value <=25, Smoke Developed Value <=50. The Flame Spread Value and Smoke Developed Value is based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per Bow installation instructions. Tubing shall be marked [cNSF®-fs ULCS102.2 FS25/SD50]. |
|||
Tubing@ [1] |
PEX |
Superpex |
ASTM E84 |
1/2" (without insulation) | |||
@ Certified Bow Superpex tubing has a blue, red, or white outer layer. [1] Flame Spread Index <=25, Smoke Developed Index <=50. Flame Spread Index and Smoke Developed Index for ASTM E84 is based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2 FS25/SD50]. |
|||
Tubing@ ¢ [2] |
PEX |
Superpex |
CAN/ULC S102.2 |
1/2" (without insulation) | |||
@ Certified Bow Superpex tubing has a blue, red, or white outer layer. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [2] Flame Spread Value <=25, Smoke Developed Value <=50. Tubing shall be marked [cNSFus® fs ASTM E84 ULC S102.2 FS25/SD50]. |
|||
Tubing@ ¢ [3] |
PEX |
Superpex |
CAN/ULC S102.2 |
1/4", 3/8", 3/4", 1" (with insulation) | |||
@ Certified Bow Superpex tubing has a blue, red, or white outer layer. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [3] Flame Spread Value <=25, Smoke Developed Value <=50. The Flame Spread Value and Smoke Developed Value is based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per Bow installation instructions. Tubing shall be marked [cNSF®-fs ULCS102.2 FS25/SD50]. |
Diamond Plastics Corporation | |
1212 Johnstown Road | |
Grand Island, NE 68803 | |
United States | |
308-384-4400 |
Facility : Casa Grande, AZ
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe+ |
PVC |
DPC Pipe/ Diamond |
FM 1612 |
PC 250: 4", 6", 8", 10", 12" DR 14 | |||
PC 185: 4", 6", 8", 10", 12" DR 18 | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
|||
Pipe+ |
PVC |
DPC Pipe/ Diamond |
UL 1285 |
PC 165: 4",6",8",10",12",14",16",18",20",24" | |||
PC 165: 30", 36" | |||
PC 235: 4", 6", 8", 10", 12", 14", 16", 18", 20" | |||
PC 235: 24", 30", 36" | |||
PC 305: 4",6",8",10",12",14",16",18",20",24",30" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
Facility : Macon, GA
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe+ |
PVC |
DPC Pipe/ Diamond |
AWWA C900 |
4", 6", 8", 10", 12", 14", 16", 18", 20", 24", 30" | |||
36", 42", 48" | |||
PC305 (DR14) in nominal diameters of 4" - 30" | |||
PC235 (DR18) in nominal diameters of 4" - 42" | |||
PC200 (DR-21) in diameters 14" - 48" | |||
PC165 (DR25) in diameters 4" - 60" | |||
PC125 (DR32.5) in diameters 16" - 60" | |||
PC100 (DR41) in diameters 20" - 60" | |||
PC80 (DR51) in diameters 24" - 60" | |||
PC50 (DR81) in diameters 36" - 60" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
|||
Pipe+ |
PVC |
DPC Pipe/ Diamond |
FM 1612 |
PC 250: 4", 6", 8", 10", 12" DR 14 | |||
PC 185: 4", 6", 8", 10", 12" DR 18 | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
|||
Pipe+ |
PVC |
DPC Pipe/ Diamond |
UL 1285 |
PC 165: 4",6",8",10",12",14",16",18",20",24" | |||
PC 165: 30", 36", 42" | |||
PC 235: 4", 6", 8", 10", 12", 14", 16", 18", 20" | |||
PC 235: 24", 30", 36", 42" | |||
PC 305: 4",6",8",10",12",14",16",18",20" | |||
PC 305: 24", 30", 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
Facility : Muncie, IN
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe + |
PVC |
DPC Pipe/ Diamond |
FM 1612 |
PC 250: 4", 6", 8", 10", 12" DR 14 | |||
PC 185: 4", 6", 8", 10", 12" DR 18 | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
|||
Pipe + |
PVC |
DPC Pipe/ Diamond |
UL 1285 |
PC 165: 4", 6", 8", 10", 12", 14", 16", 18", 20" | |||
PC 165: 24", 30" | |||
PC 165: 38", 40", 42" | |||
PC 235: 4", 6", 8", 10", 12", 14", 16", 18", 20" | |||
PC 235: 24", 30" | |||
PC 305: 4",6",8",10",12",14",16",18",20",24",30" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
* Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
Facility : Plaquemine, LA
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe + |
PVC |
DPC Pipe/ Diamond |
FM 1612 |
PC 250: 4", 6", 8", 10", 12" DR 14 | |||
PC 185: 4", 6", 8", 10", 12" DR 18 | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
|||
Pipe+ |
PVC |
DPC Pipe/ Diamond |
UL 1285 |
PC 165: 4",6",8",10",12",14",16",18",20",24" | |||
PC 165: 30" | |||
PC 235: 4", 6", 8", 10", 12", 14", 16", 18", 20" | |||
PC 235: 24", 30" | |||
PC 305: 4",6",8",10",12",14",16",18",20",24",30" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
Facility : Grand Island, NE
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe+ |
PVC |
DPC Pipe/ Diamond |
AWWA C900 |
4", 6", 8", 10", 12", 14", 16", 18", 20", 24", 30" | |||
36", 42", 48", 54", 60" | |||
PC305 (DR14) in nominal diameters of 4" - 30" | |||
PC235 (DR18) in nominal diameters of 4" - 42" | |||
PC200 (DR-21) in diameters 14" - 48" | |||
PC165 (DR25) in diameters 4" - 60" | |||
PC125 (DR32.5) in diameters 16" - 60" | |||
PC100 (DR41) in diameters 20" - 60" | |||
PC80 (DR51) in diameters 24" - 60" | |||
PC50 (DR81) in diameters 36" - 60" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
|||
Pipe+ |
PVC |
DPC Pipe/ Diamond/ Diamon Lok-21 |
FM 1612 |
PC 250: 4", 6", 8", 10", 12" DR 14 | |||
PC 185: 4", 6", 8", 10", 12" DR 18 | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
|||
Pipe+ |
PVC |
DPC Pipe/ Diamond |
UL 1285 |
PC 165: 4",6",8",10",12",14",16",18",20",24" | |||
PC 165: 30", 36" | |||
PC 235: 4", 6", 8", 10", 12", 14", 16", 18", 20" | |||
PC 235: 24", 30", 36", 42" | |||
PC 305: 4",6",8",10",12",14",16",18",20" | |||
PC 305: 24", 30", 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
Facility : Golconda, NV
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe+ |
PVC |
DPC Pipe/ Diamond |
FM 1612 |
PC 250: 4", 6", 8", 10", 12" DR 14 | |||
PC 185: 4", 6", 8", 10", 12" DR 18 | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
|||
Pipe+ |
PVC |
DPC Pipe/ Diamond |
UL 1285 |
PC 165: 4",6",8",10",12",14",16",18",20",24" | |||
PC 165: 30", 36", 42" | |||
PC 235: 4", 6", 8", 10", 12", 14", 16", 18", 20" | |||
PC 235: 24", 30", 36", 42" | |||
PC 305: 4",6",8",10",12",14",16",18",20" | |||
PC 305: 24", 30", 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
Facility : Lubbock, TX
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe+ |
PVC |
DPC Pipe/ Diamond/ Diamond Lok-21 |
FM 1612 |
PC 250: 4", 6", 8", 10", 12" DR 14 | |||
PC 185: 4", 6", 8", 10", 12" DR 18 | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
|||
Pipe+ |
PVC |
DPC Pipe/ Diamond |
UL 1285 |
PC 165: 4",6",8",10",12",14",16",18",20",24" | |||
PC 165: 30", 36" | |||
PC 235: 4", 6", 8", 10", 12", 14", 16", 18", 20" | |||
PC 235: 24", 30", 36" | |||
PC 305: 4",6",8",10",12",14",16",18",20" | |||
PC 305: 24", 30", 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
Empresa Mexicana de Manufacturas S.A. de C.V. DBA EMMSA | |
AV Pedro Ramirez Vazquez Numero Exterior | |
200-13 Numero Interior Piso 5 Colonia | |
Valle Oriente, San Pedro Garza Garcia | |
Nuevo Léon 66269, | |
Mexico | |
52 818 088 7495 | |
Visit this company's website |
Facility : Garcia, Nuevo Leon, Mexico
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe# + [G] |
PVC |
EMMSA |
FM 1612 |
4" SDR 14, 18 | |||
6" SDR 14, 18 | |||
8" SDR 14, 18 | |||
10" SDR 14, 18 | |||
12" SDR 14, 18 | |||
# This product may be marked with an alternate trade name: CRESCO; [CRESCO logo] or Durafort by CRESCO and/or [Durafort by CESCO logo]. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||
Pipe# + [G] |
PVC |
EMMSA |
UL 1285 |
4" SDR 14, 18, 25 | |||
6" SDR 14, 18, 25 | |||
8" SDR 14, 18, 25 | |||
10" SDR 14, 18, 25 | |||
12" SDR 14, 18, 25 | |||
# This product may be marked with an alternate trade name: CRESCO; [CRESCO logo] or Durafort by CRESCO and/or [Durafort by CESCO logo]. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Everhot Inc. | |
5407 Foster Avenue | |
Brooklyn, NY 11234 | |
United States | |
347-492-7660 |
Facility : # 1 China
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing# $ * |
PEX |
Everhot |
ASTM E84 |
3/8", 1/2" - 2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation instructions. The 3/8" tubing is not insulated. $ Certified for blue, natural, red, and white without oxygen barrier. * Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
|||
Tubing$ & |
PEX |
Everhot |
CAN/ULC S102.2 |
3/8", 1/2" - 2" |
|||
Flame Spread Rating <= 25 | Smoke Developed Classification <= 50 | ||
$ Certified for blue, natural, red, and white without oxygen barrier. & 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50]. 1/2" - 2" tubing (with insulation), Flame Spread Index and Smoke Developed Index based on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. |
Heatlink Group INC. | |
11500 - Stonehill Drive NE | |
#115 | |
Calgary, AB T3N 2M7 | |
Canada | |
403-717-3820 |
Facility : P3 USA
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing^ § ** |
PEX |
PureLink Plus |
ASTM E84 |
1/2", 3/4" | |||
^ Flame Spread Index <= 25, Smoke Developed Index <= 50 § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. ** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
|||
Tubing^ § ** |
PEX |
SureLink |
ASTM E84 |
1/2", 3/4" | |||
^ Flame Spread Index <= 25, Smoke Developed Index <= 50 § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. ** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
Fire Sprinkler Pipe and Fitting Systems
Product Type | Material Type | Trade Name | Product Standard |
Pipe and Fitting System% ** ¢ |
MLTPL |
PureLink Plus * |
ANSI/CAN/UL 1821 |
Adapter |
|||
3/4" PEX F1960 × 3/4" M/Sweat No Lead Brass Adapter (EX27122NL) | 1" PEX F1960 × 1" M/Sweat No Lead Brass Adapter (EX27128NL) | 1-1/4" PEX F1960 × 1-1/4" M/Sweat No Lead Brass Adapter (EX27135NL) | 1-1/2" PEX F1960 × 1-1/2" M/Sweat No Lead Brass Adapter (EX27141NL) |
2" PEX F1960 × 2" M/Sweat No Lead Brass Adapter (EX27154NL) | 3/4" PEX F1960 × 3/4" F/Sweat No Lead Brass Adapter (EX27222NL) | 1" PEX F1960 × 1" F/Sweat No Lead Brass Adapter (EX27228NL) | 1-1/4" PEX F1960 × 1-1/4" F/Sweat No Lead Brass Adapter (EX27235NL) |
1-1/2" PEX F1960 × 1-1/2" F/Sweat No Lead Brass Adapter (EX27241NL) | 2" PEX F1960 × 2" F/Sweat No Lead Brass Adapter (EX27254NL) | 3/4" PEX F1960 × 3/4" MNPT No Lead Brass Adapter (EX27522NL) | 1" PEX F1960 × 1" MNPT No Lead Brass Adapter (EX27528NL) |
1-1/4" PEX F1960 × 1-1/4" MNPT No Lead Brass Adapter (EX27535NL) | N/A1-1/2" PEX F1960 × 1-1/2" MNPT No Lead Brass Adapter (EX27541NL) | 2" PEX F1960 × 2" MNPT No Lead Brass Adapter (EX27554NL) | 3/4" PEX F1960 × 3/4" FNPT No Lead Brass Adapter (EX27622NL) |
1" PEX F1960 × 1" FNPT No Lead Brass Adapter (EX27628NL) | 1-1/4" PEX F1960 × 1-1/4" FNPT No Lead Brass Adapter (EX27635NL) | 1-1/2" PEX F1960 × 1-1/2" FNPT No Lead Brass Adapter (EX27641NL) | 3/4" PEX F1960 × 1/2" M/Sweat No Lead Brass Adapter (EX27125NL) |
N/A3/4" PEX F1960 × 1/2" F/Sweat No Lead Brass Adapter (EX27225NL) | 3/4" PEX F1960 × 1/2" MNPT No Lead Brass Adapter (EX27525NL) | ||
Coupling |
|||
3/4" × 3/4" PEX F1960 HPP Coupling (EX19022) | 1" × 1" PEX F1960 HPP Coupling (EX19028) | 1-1/4" × 1-1/4" PEX F1960 HPP Coupling (EX19035) | 1-1/2" × 1-1/2" PEX F1960 HPP Coupling (EX19041) |
2" × 2" PEX F1960 HPP Coupling (EX19054) | 1-1/4" × 1" PEX F1960 HPP Coupling (EX19238) | 1-1/2" × 1-1/4" PEX F1960 HPP Coupling (EX19243) | 1-1/2" × 1" PEX F1960 HPP Coupling (EX19248) |
2" × 1-1/2" PEX F1960 HPP Coupling (EX19264) | 1" × 3/4" PEX F1960 HPP Coupling (EX19282) | 3/4" × 1/2" PEX F1960 HPP Coupling (EX19225) | |
Elbow |
|||
3/4" × 3/4" PEX F1960 HPP Elbow EX18022 | 1" × 1" PEX F1960 HPP Elbow EX18028 | 1-1/4" × 1-1/4" PEX F1960 HPP Elbow EX18035 | 1-1/2" × 1-1/2" PEX F1960 HPP Elbow EX18041 |
2" × 2" PEX F1960 HPP Elbow EX18054 | |||
Expansion Rings |
|||
3/4" PEX F1960 HPP Expansion Ring | 1" PEX F1960 HPP Expansion Ring | 1-1/4" PEX F1960 HPP Expansion Ring | 1-1/2" PEX F1960 HPP Expansion Ring |
2" PEX F1960 HPP Expansion Ring | |||
Plugs |
|||
3/4" PEX F1960 HPP Plug (EX15022) | 1" PEX F1960 HPP Plug (EX15028) | 1-1/4" PEX F1960 HPP Plug (EX15035) | 1-1/2" PEX F1960 HPP Plug (EX15041) |
2" PEX F1960 HPP Plug (EX15054) | |||
Tees |
|||
3/4" × 3/4" × 3/4" PEX F1960 HPP Tee (EX16222) | 1-1/4" × 1-1/4" × 3/4" PEX F1960 HPP Tee (EX16332) | 1-1/4" × 1-1/4" × 1-1/4" PEX F1960 HPP Tee (EX16333) | 1-1/4" × 1-1/4" × 1" PEX F1960 HPP Tee (EX16338) |
1-1/4" × 1" × 3/4" PEX F1960 HPP Tee (EX16382) | N1-1/4" × 1" × 1" PEX F1960 HPP Tee (EX16388) | 1-1/2" × 1-1/4" × 3/4" PEX F1960 HPP Tee (EX16432) | 1-1/2" × 1-1/4" × 1-1/4" PEX F1960 HPP Tee (EX16433) |
1-1/2" × 1-1/4" × 1" PEX F1960 HPP Tee (EX16438) | 1-1/2" × 1-1/2" × 3/4" PEX F1960 HPP Tee (EX16442) | 1-1/2" × 1-1/2" × 1-1/4" PEX F1960 HPP Tee (EX16443) | 1-1/2" × 1-1/2" × 1-1/2" PEX F1960 HPP Tee (EX16444) |
1-1/2" × 1-1/2" × 1" PEX F1960 HPP Tee (EX16448) | 1-1/2" × 1" × 1" PEX F1960 HPP Tee (EX16488) | 2" × 1-1/2" × 3/4" PEX F1960 HPP Tee (EX16642) | 2" × 1-1/2" × 1-1/4" PEX F1960 HPP Tee (EX16643) |
2" × 1-1/2" × 1-1/2" PEX F1960 HPP Tee (EX16644) | 2" × 1-1/2" × 1" PEX F1960 HPP Tee (EX16648) | 2" × 2" × 3/4" PEX F1960 HPP Tee (EX16662) | 2" × 2" × 1-1/4" PEX F1960 HPP Tee (EX16663) |
2" × 2" × 1-1/2" PEX F1960 HPP Tee (EX16664) | 2" × 2" × 2" PEX F1960 HPP Tee (EX16666) | 2" × 2" × 1" PEX F1960 HPP Tee (EX16668) | 1" × 3/4" × 3/4" PEX F1960 HPP Tee (EX16822) |
1" × 3/4" × 1" PEX F1960 HPP Tee (EX16828) | 1" × 1" × 3/4" PEX F1960 HPP Tee (EX16882) | 1" × 1" × 1" PEX F1960 HPP Tee (EX16888) | 3/4" × 3/4" × 1/2" PEX F1960 HPP Tee (EX16225) |
3/4" × 1/2" × 3/4" PEX F1960 HPP Tee (EX16252) | 3/4" × 1/2" × 1/2" PEX F1960 HPP Tee (EX16255) | 1-1/4" × 1-1/4" × 1/2" PEX F1960 HPP Tee (EX16335) | 1-1/2" × 1-1/2" × 1/2" PEX F1960 HPP Tee (EX16445) |
1/2" × 1/2" × 3/4" PEX F1960 HPP Tee (EX16552) | 2" × 2" × 1/2" PEX F1960 HPP Tee (EX16665) | 1" × 1" × 1/2" PEX F1960 HPP Tee (EX16885) | |
Tubing |
|||
3/4" - PureLink Plus (White, Red, Blue) | 1" - PureLink Plus (White, Red, Blue) | 1 1/4" - PureLink Plus (White, Red, Blue) | 1 1/2" - PureLink Plus (White, Red, Blue) |
2" - PureLink Plus (White, Red, Blue) | |||
% PEX pipe and fittings are intended for use in multi-purpose piping systems of residential occupancies as defined in ANSI/NFPA 13D, "Installation of Sprinkler Systems in One- and Two- Family Dwellings and Manufactured Homes", the National Building Code of Canada, and the International Residential Code, Section 2904, and are designed to withstand a working pressure of not less than 130 psi at 120° F. PEX pipe and fittings are intended to be installed in accordance with the requirements specified in the manufacturer’s installation instructions and ANSI/NFPA 13D. Protection is intended to be provided for PEX pipe and fittings in multi-purpose piping systems. The minimum protection should consist of either (1) one layer of 3/8-in. gypsum wallboard, (2) a suspended membrane ceiling with lay-in panels or tiles having a weight of not less than 0.35 lbs per sq ft when installed with metallic support grids, or (3) 1/2 in plywood. PEX pipe and fittings are intended for use in areas where the maximum ambient temperature does not exceed 120° F. These pipe and fittings are not intended to be installed in outdoor applications. The PEX pipe and fittings are intended for use in wet-pipe systems only and have not been evaluated for use in dry-pipe systems. ** Pipe and fittings Certified as a system using installation and design manual titled "SureLink™ Fire Safety System". ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. |
* These products may also be represented by the trade name SureLink™.
Facility : Calgary, Alberta, Canada
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing^ § ** |
PEX |
PureLink Plus |
ASTM E84 |
1/2", 3/4" | |||
^ Flame Spread Index <= 25, Smoke Developed Index <= 50 § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. ** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
|||
Tubing^ § ** |
PEX |
SureLink |
ASTM E84 |
1/2", 3/4" | |||
^ Flame Spread Index <= 25, Smoke Developed Index <= 50 § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. ** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
Fire Sprinkler Pipe and Fitting Systems
Product Type | Material Type | Trade Name | Product Standard |
Pipe and Fitting System% ** ¢ |
MLTPL |
PureLink Plus * |
ANSI/CAN/UL 1821 |
Adapter |
|||
3/4" PEX F1960 × 3/4" M/Sweat No Lead Brass Adapter (EX27122NL) | 1" PEX F1960 × 1" M/Sweat No Lead Brass Adapter (EX27128NL) | 1-1/4" PEX F1960 × 1-1/4" M/Sweat No Lead Brass Adapter (EX27135NL) | 1-1/2" PEX F1960 × 1-1/2" M/Sweat No Lead Brass Adapter (EX27141NL) |
2" PEX F1960 × 2" M/Sweat No Lead Brass Adapter (EX27154NL) | 3/4" PEX F1960 × 3/4" F/Sweat No Lead Brass Adapter (EX27222NL) | 1" PEX F1960 × 1" F/Sweat No Lead Brass Adapter (EX27228NL) | 1-1/4" PEX F1960 × 1-1/4" F/Sweat No Lead Brass Adapter (EX27235NL) |
1-1/2" PEX F1960 × 1-1/2" F/Sweat No Lead Brass Adapter (EX27241NL) | 2" PEX F1960 × 2" F/Sweat No Lead Brass Adapter (EX27254NL) | 3/4" PEX F1960 × 3/4" MNPT No Lead Brass Adapter (EX27522NL) | 1" PEX F1960 × 1" MNPT No Lead Brass Adapter (EX27528NL) |
1-1/4" PEX F1960 × 1-1/4" MNPT No Lead Brass Adapter (EX27535NL) | N/A1-1/2" PEX F1960 × 1-1/2" MNPT No Lead Brass Adapter (EX27541NL) | 2" PEX F1960 × 2" MNPT No Lead Brass Adapter (EX27554NL) | 3/4" PEX F1960 × 3/4" FNPT No Lead Brass Adapter (EX27622NL) |
1" PEX F1960 × 1" FNPT No Lead Brass Adapter (EX27628NL) | 1-1/4" PEX F1960 × 1-1/4" FNPT No Lead Brass Adapter (EX27635NL) | 1-1/2" PEX F1960 × 1-1/2" FNPT No Lead Brass Adapter (EX27641NL) | 3/4" PEX F1960 × 1/2" M/Sweat No Lead Brass Adapter (EX27125NL) |
N/A3/4" PEX F1960 × 1/2" F/Sweat No Lead Brass Adapter (EX27225NL) | 3/4" PEX F1960 × 1/2" MNPT No Lead Brass Adapter (EX27525NL) | ||
Coupling |
|||
3/4" × 3/4" PEX F1960 HPP Coupling (EX19022) | 1" × 1" PEX F1960 HPP Coupling (EX19028) | 1-1/4" × 1-1/4" PEX F1960 HPP Coupling (EX19035) | 1-1/2" × 1-1/2" PEX F1960 HPP Coupling (EX19041) |
2" × 2" PEX F1960 HPP Coupling (EX19054) | 1-1/4" × 1" PEX F1960 HPP Coupling (EX19238) | 1-1/2" × 1-1/4" PEX F1960 HPP Coupling (EX19243) | 1-1/2" × 1" PEX F1960 HPP Coupling (EX19248) |
2" × 1-1/2" PEX F1960 HPP Coupling (EX19264) | 1" × 3/4" PEX F1960 HPP Coupling (EX19282) | 3/4" × 1/2" PEX F1960 HPP Coupling (EX19225) | |
Elbow |
|||
3/4" × 3/4" PEX F1960 HPP Elbow EX18022 | 1" × 1" PEX F1960 HPP Elbow EX18028 | 1-1/4" × 1-1/4" PEX F1960 HPP Elbow EX18035 | 1-1/2" × 1-1/2" PEX F1960 HPP Elbow EX18041 |
2" × 2" PEX F1960 HPP Elbow EX18054 | |||
Expansion Rings |
|||
3/4" PEX F1960 HPP Expansion Ring | 1" PEX F1960 HPP Expansion Ring | 1-1/4" PEX F1960 HPP Expansion Ring | 1-1/2" PEX F1960 HPP Expansion Ring |
2" PEX F1960 HPP Expansion Ring | |||
Plugs |
|||
3/4" PEX F1960 HPP Plug (EX15022) | 1" PEX F1960 HPP Plug (EX15028) | 1-1/4" PEX F1960 HPP Plug (EX15035) | 1-1/2" PEX F1960 HPP Plug (EX15041) |
2" PEX F1960 HPP Plug (EX15054) | |||
Tees |
|||
3/4" × 3/4" × 3/4" PEX F1960 HPP Tee (EX16222) | 1-1/4" × 1-1/4" × 3/4" PEX F1960 HPP Tee (EX16332) | 1-1/4" × 1-1/4" × 1-1/4" PEX F1960 HPP Tee (EX16333) | 1-1/4" × 1-1/4" × 1" PEX F1960 HPP Tee (EX16338) |
1-1/4" × 1" × 3/4" PEX F1960 HPP Tee (EX16382) | N1-1/4" × 1" × 1" PEX F1960 HPP Tee (EX16388) | 1-1/2" × 1-1/4" × 3/4" PEX F1960 HPP Tee (EX16432) | 1-1/2" × 1-1/4" × 1-1/4" PEX F1960 HPP Tee (EX16433) |
1-1/2" × 1-1/4" × 1" PEX F1960 HPP Tee (EX16438) | 1-1/2" × 1-1/2" × 3/4" PEX F1960 HPP Tee (EX16442) | 1-1/2" × 1-1/2" × 1-1/4" PEX F1960 HPP Tee (EX16443) | 1-1/2" × 1-1/2" × 1-1/2" PEX F1960 HPP Tee (EX16444) |
1-1/2" × 1-1/2" × 1" PEX F1960 HPP Tee (EX16448) | 1-1/2" × 1" × 1" PEX F1960 HPP Tee (EX16488) | 2" × 1-1/2" × 3/4" PEX F1960 HPP Tee (EX16642) | 2" × 1-1/2" × 1-1/4" PEX F1960 HPP Tee (EX16643) |
2" × 1-1/2" × 1-1/2" PEX F1960 HPP Tee (EX16644) | 2" × 1-1/2" × 1" PEX F1960 HPP Tee (EX16648) | 2" × 2" × 3/4" PEX F1960 HPP Tee (EX16662) | 2" × 2" × 1-1/4" PEX F1960 HPP Tee (EX16663) |
2" × 2" × 1-1/2" PEX F1960 HPP Tee (EX16664) | 2" × 2" × 2" PEX F1960 HPP Tee (EX16666) | 2" × 2" × 1" PEX F1960 HPP Tee (EX16668) | 1" × 3/4" × 3/4" PEX F1960 HPP Tee (EX16822) |
1" × 3/4" × 1" PEX F1960 HPP Tee (EX16828) | 1" × 1" × 3/4" PEX F1960 HPP Tee (EX16882) | 1" × 1" × 1" PEX F1960 HPP Tee (EX16888) | 3/4" × 3/4" × 1/2" PEX F1960 HPP Tee (EX16225) |
3/4" × 1/2" × 3/4" PEX F1960 HPP Tee (EX16252) | 3/4" × 1/2" × 1/2" PEX F1960 HPP Tee (EX16255) | 1-1/4" × 1-1/4" × 1/2" PEX F1960 HPP Tee (EX16335) | 1-1/2" × 1-1/2" × 1/2" PEX F1960 HPP Tee (EX16445) |
1/2" × 1/2" × 3/4" PEX F1960 HPP Tee (EX16552) | 2" × 2" × 1/2" PEX F1960 HPP Tee (EX16665) | 1" × 1" × 1/2" PEX F1960 HPP Tee (EX16885) | |
Tubing |
|||
3/4" - PureLink Plus (White, Red, Blue) | 1" - PureLink Plus (White, Red, Blue) | 1 1/4" - PureLink Plus (White, Red, Blue) | 1 1/2" - PureLink Plus (White, Red, Blue) |
2" - PureLink Plus (White, Red, Blue) | |||
% PEX pipe and fittings are intended for use in multi-purpose piping systems of residential occupancies as defined in ANSI/NFPA 13D, "Installation of Sprinkler Systems in One- and Two- Family Dwellings and Manufactured Homes", the National Building Code of Canada, and the International Residential Code, Section 2904, and are designed to withstand a working pressure of not less than 130 psi at 120° F. PEX pipe and fittings are intended to be installed in accordance with the requirements specified in the manufacturer’s installation instructions and ANSI/NFPA 13D. Protection is intended to be provided for PEX pipe and fittings in multi-purpose piping systems. The minimum protection should consist of either (1) one layer of 3/8-in. gypsum wallboard, (2) a suspended membrane ceiling with lay-in panels or tiles having a weight of not less than 0.35 lbs per sq ft when installed with metallic support grids, or (3) 1/2 in plywood. PEX pipe and fittings are intended for use in areas where the maximum ambient temperature does not exceed 120° F. These pipe and fittings are not intended to be installed in outdoor applications. The PEX pipe and fittings are intended for use in wet-pipe systems only and have not been evaluated for use in dry-pipe systems. ** Pipe and fittings Certified as a system using installation and design manual titled "SureLink™ Fire Safety System". ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. |
* These products may also be represented by the trade name SureLink™.
Huaru Pipe Inc | |
116 Maple Street | |
Commerce, TX 75428 | |
United States | |
315-418-0770 |
Facility : Commerce, TX
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing[1] [2] |
PEX |
Valtec |
CAN/ULC S102.2 |
1/2" | |||
[1] Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50]. [2] Flame Spread Value (FSV) <= 25 Smoke Developed Value (SDV) <= 50 |
|||
Tubing[1] [3] |
PEX |
Valtec |
ASTM E84 |
1/2" | |||
[1] Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50]. [3] Flame Spread Index <= 25 Smoke Developed Index <=50 |
IPEX Incorporated | |
3 Place Du Commerce, Suite 101 | |
Île-Des-Soeurs | |
Verdun, QC H3E 1H7 | |
Canada | |
514-769-2200 | |
Visit this company's website |
Facility : Mississauga, Ontario, Canada
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Fittings~ [1] [2] [3] |
PVC |
System XFR |
CAN/ULC S102.2 |
101002 ELBOW 180° FOR 526431 | 101004 ELBOW 180° FOR 526441 | 101009 ELBOW 180° FOR 526505 | 101011 ELBOW 180° FOR 526443 |
101012 ELBOW 180° FOR 526444 | 101013 ELBOW 180° FOR 526432 | 101014 ELBOW 180° FOR 526442 | 101015 ELBOW 180° FOR 526433 |
101016 ELBOW 180° FOR 526434 | 101018 ELBOW 90° FOR 526431 | 101019 ELBOW 90° FOR 526432 | 101020 ELBOW 90° FOR 526433 |
101021 ELBOW 90° FOR 526434 | 101023 ELBOW 90° FOR 526443 | 101024 ELBOW 90° FOR 526444 | 101031 PVC DWV MAIN PIECE FOR 526321 |
101032 PVC DWV MAIN PIECE FOR 526329 | 101034 PVC DWV MAIN PIECE FOR 526555 | 101035 PVC DWV MAIN PIECE FOR 526556 | 101037 PVC DWV MAIN PIECE FOR 526586 |
101039 PVC DWV RING FOR 526586 & 526588 | 101041 PVC DWV MAIN PIECE FOR 526330 | 101045 PVC DWV MAIN PIECE FOR 526485 | 101046 PVC DWV MAIN PIECE FOR 526486 |
101047 PVC DWV MAIN PIECE FOR 526487 | 101048 PVC DWV MAIN PIECE FOR 526494 | 101066 PVC DWV NUT 1½" | 101068 PVC DWV NUT 2" |
101104 PVC DWV MAIN PIECE FOR 526104 | 101105 PVC DWV MAIN PIECE FOR 526105 | 101134 PVC DWV MAIN PIECE FOR 526040 | 101135 PVC DWV MAIN PIECE FOR 526041 |
101136 PVC DWV MAIN PIECE FOR 526103 | 101161 PVC DWV MAIN PIECE FOR 526161 | 101401 PVC DWV 1 1/2" PLUG MPT | 101402 PVC DWV 2" PLUG MPT |
101403 PVC DWV 3" PLUG MPT | 101404 PVC DWV 4" PLUG MPT | 101405 PVC DWV 6" PLUG MPT | 101588 PVC DWV MAIN PIECE FOR 526588 |
101601 PVC DWV 1 1/2" CLEANOUT SPXFPT | 101602 PVC DWV 2" CLEANOUT SPXFPT | 101603 PVC DWV 3" CLEANOUT SPXFPT | 101604 PVC DWV 4" CLEANOUT SPXFPT |
101606 PVC DWV 6" CLEANOUT SPXFPT | 101630 NUT 1¼" | 101631 NUT 1½" | 101890 THREAD CAP FOR P-TRAP |
526003 P-TRAP PRIMER TEE 3" X 3" X ½" HXHXFPT | 526011 P-TRAP PRIMER TEE 4" X 4" X ½" HXHXFPT | 526025 PVC DWV 3" 90° SHORT ELBOW HXH | 526035 PVC DWV 2" 90° SHORT ELBOW HXH |
526040 PVC DWV 1 1/2" CLEANOUT TEE W/P PVC | 526041 PVC DWV 2" CLEANOUT TEE W/P PVC | 526042 PVC DWV 1 1/2" CLEANOUT W/O PLUG | 526046 PVC DWV 2" CLEANOUT W/O PLUG |
526047 PVC DWV 3" CLEANOUT W/O PLUG | 526056 PVC DWV 2" X 2" X 1 1/2" TY HXHXH | 526058 PVC DWV 2" X 1 1/2" X 1 1/2" TY HXHXH | 526060 PVC DWV 3" X 3" X 2" TY HXHXH |
526061 PVC DWV 3" X 3" X 1 1/2" TY HXHXH | 526064 PVC DWV 4" X 4" X 2" TY HXHXH | 526066 PVC DWV 4" X 4" X 3" TY HXHXH | 526071 PVC DWV 2" 45° ELBOW HXS |
526072 PVC DWV 4" 45° HXS | 526081 PVC DWV 1 1/2" TY HXHXH | 526082 PVC DWV 2" TY HXHXH | 526083 PVC DWV 3" TY HXHXH |
526084 PVC DWV 4" TY HXHXH | 526103 PVC DWV 3" CLEANOUT TEE W/P PVC | 526104 PVC DWV 4" CLEANOUT TEE W/P PVC | 526105 PVC DWV 4" X 3" X 4" CLEANOUT T W/P PVC |
526121 PVC DWV 1 1/2" 90° DEG ELBOW HXH | 526122 PVC DWV 2" 90°ELBOW HXH | 526123 PVC DWV 3" 90° ELBOW HXH | 526124 PVC DWV 4" 90°ELBOW HXH |
526161 PVC DWV 6" CLEANOUT TEE W/P PVC | 526171 PVC DWV 1 1/2" 45° Y HXHXH | 526172 PVC DWV 2" 45° Y HXHXH | 526173 PVC DWV 3" 45° Y HXHXH |
526174 PVC DWV 4" 45° Y HXHXH | 526175 PVC DWV 6" Y HXHXH | 526194 PVC DWV 2" X 1 1/2" X 1 1/2" Y HXHXH | 526195 PVC DWV 2" X 2" X 1 1/2" Y HXHXH |
526196 PVC DWV 3" X 3" X 2" Y HXHXH | 526197 PVC DWV 4" X 4" X 3" Y HXHXH | 526198 PVC DWV 4" X 4" X 2" Y HXHXH | 526199 PVC DWV 6" X 6" X 4" Y HXHXH |
526201 PVC DWV 3" X 3" X 1 1/2" Y HXHXH | 526221 PVC DWV 1 1/2" 45° ELBOW HXS | 526223 PVC DWV 3" 45° ELBOW HXS | 526231 PVC DWV 1 1/2" 90° ELBOW HXS |
526232 PVC DWV 2" 90° ELBOW HXS | 526233 PVC DWV 3" 90° ELBOW HXS | 526234 PVC DWV 4" 90° ELBOW SPxH | 526241 PVCDWV 1 1/2" 45° ELBOW HXH |
526242 PVC DWV 2" 45° ELBOW HXH | 526243 PVC DWV 3" 45° ELBOW HXH | 526244 PVC DWV 4" 45° ELBOW HXH | 526251 PVC DWV 1 1/2" 22.5° ELBOW HxH |
526252 PVC DWV 2" 22.5° ELBOW HxH | 526253 PVC DWV 3" 22.5° ELBOW HxH | 526254 PVC DWV 4" 22.5° ELBOW HxH | 526261 PVC DWV 1 1/2" 60° ELBOW HxH |
526262 PVC DWV 2" 60° ELBOW HxH | 526263 PVC DWV 3" 60° ELBOW HxH | 526264 PVC DWV 4" 60° ELBOW HXH | 526277 PVC DWV 1 1/2" X 1/2" DISH.ADAPT. |
526282 PVC DWV 2" x 1/2" RED. BUSHING SXH | 526284 PVC DWV 3" X 2" REDUC. BUSH. SPxH | 526286 PVC DWV 4" X 3" REDUC. BUSH. SPxH | 526288 PVC DWV 4" X 2" REDUC. BUSH. SPxH |
526291 PVC/DWV 1 1/2" TUBE END C/O W/P PVC | 526292 PVC DWV 3" x 1 1/2" REDUC. BUSH. SPxH | 526294 PVC DWV 4" X 3" REDUC. BUSH. SPxH | 526277 PVC DWV 1 1/2"x1/2" XFR Red. Bushing SpxFPT |
526278 PVC DWV1 1/2"x 3/4" XFR Red. Bushing SpxFPT | 526298 PVC/DWV 2" TUBE END C/O W/P PVC | 526299 PVC/DWV 3" TUBE END C/O W/P PVC | 526300 PVC/DWV 4" TUBE END C/O W/P PVC |
526310 PVC DWV 2" AD.SEWER TO DWV SPXH | 526311 PVC DWV 3"AD.SEWER to DWV SPXH | 526312 PVC DWV 4" AD.SEWER to DWV SPXH | 526313 PVC DWV 6" ADAPT SEWER TO DWV HXS |
526321 PVC DWV 1 1/2" TRAP ADAP. H | 526329 PVC DWV 1 1/2" X 1 1/4" TRAP ADAP. H | 526330 1 1/2" 90° ELBOW W/SLIP JOINT NUT | 526331 PVC DWV 1 1/2" ADAPTER HxMPT |
526332 PVC DWV 2" ADAPTER HxMPT | 526333 PVC DWV 3" ADAPTER HxMPT | 526334 PVC DWV 4" ADAPTER HxMPT | 526341 PVC DWV 1 1/2" ADAPTER HxFPT |
526342 PVC DWV 2" ADAPTER HxFPT | 526343 PVC DWV 3" ADAPTER HxFPT | 526344 PVC DWV 4" ADAPTER HxFPT | 526345 PVC DWV 1 1/2" CLEANOUT W/PLUG PVC |
526346 PVC DWV 2" CLEANOUT W/PLUG PVC | 526347 PVC DWV 3" CLEANOUT W/PLUG PVC | 526348 PVC DWV 4" CLEANOUT W/PLUG PVC | 526349 PVC DWV 6" CLEANOUT W/PLUG PVC |
526351 PVC DWV 1 1/2" COUPLING HXH | 526352 PVC DWV 2" COUPLING HXH | 526353 PVC DWV 3" COUPLING HXH | 526354 PVC DWV 4" COUPLING HXH |
526362 PVC DWV 2" X 1 1/2" COUPLING HXH | 526363 PVC DWV 3" X 1 1/2" COUPLING HXH | 526364 PVC DWV 3" X 2" COUPLING HXH | 526365 PVC DWV 4" X 2" COUPLING HXH |
526366 PVC DWV 4" X 3" COUPLING HXH | 526369 PVC DWV 4" X 1 1/2" COUPLING HXH | 526376 PVC DWV 4" X 3" COUPLING HXH | 526395 PVC DWV 3" X 1 1/2" INLET LEFT HAND |
526396 PVC DWV 3" X 2" INLET LEFT HAND | 526397 PVC DWV 3" X 1 1/2" INLET RIGHT HAND | 526398 PVC DWV 3" X 2" INLET RIGHT HAND | 526018 PVC DWV 3X1.5 DOUBLE INLET |
526402 PVC DWV 2" GASKET PLUG | 526404 PVC DWV 4" GASKET PLUG | 526405 PVC DWV 6" GASKET PLUG | 526411 PVC DWV 1 1/2" PERMANENT CAP |
526412 PVC DWV 2" PERMANENT CAP | 526413 PVC DWV 3" PERMANENT CAP | 526414 PVC DWV 4" PERMANENT CAP | 526431 PVC DWV 1 1/2" P-TRAP |
526432 PVC DWV 2" P-TRAP | 526433 PVC DWV 3" P-TRAP | 526434 PVC DWV 4" P-TRAP | 526441 PVC DWV 1 1/2" P-TRAP W/PLUG |
526442 PVC DWV 2" P-TRAP W/PLUG | 526443 PVC DWV 1 1/2" P-TRAP DOUBLE SEAL | 526444 PVC DWV 2" P-TRAP DOUBLE SEAL | 526485 PVC DWV 1½" EXPANSION JOINT HXH |
526486 PVC DWV 2" EXPANSION JOINT HXH | 526487 PVC DWV 3" EXPANSION JOINT HXH | 526494 PVC DWV 3" EXPANSION JOINT HXS | 526495 DISHWASHER Y 1½" HXHXBARBS |
526499 PVC DWV ELBOW 4" 180° HXH | 526505 PVC DWV 1 1/2" P-TRAP DOUBLE SEAL W/P | 526522 PVC DWV 2" CAST IRON ADAPT MJ | 526523 PVC DWV 3" CAST IRON ADAPT MJ |
526524 PVC DWV 4" CAST IRON ADAPT MJ | 526535 PVC DWV 4" X 3" CAST IRON ADAPT MJ | 526538 PVC DWV 3" X 1 1/2" DOUBLE TY HXHXHXH | 526542 PVC DWV 1 1/2" DOUBLE TY HXHXHXH |
526543 PVC DWV 2" DOUBLE TY HXHXHXH | 526547 PVC DWV 2" X 1 1/2" DOUBLE TY HXHXHXH | 526550 PVC DWV 1 1/2" TY SXHXH | 526552 PVC DWV 3" X 3" X 1 1/2" TY SXHXH |
526555 PVC DWV 1 1/2" TRAP ADAPT. M | 526556 PVC DWV 1 1/2" X 1 1/4" TRAP ADAPT. M | 526573 PVC DWV 4" CLOSET FLANGE H | 526584 PVC DWV 4" X 3" CLOSET FLANGE H |
526586 PVC DWV 4" X 3" CLOSET FLANGE ADJUST. | 526588 PVC DWV 4" X 3" CLO FLANGE ADJ W/C H | 526591 PVC DWV 4" X 3" CLOSET FLANGE W/CAP | 526592 PVC DWV 4" X 3" CLOSET FLANGE SP |
526637 PVC DWV 1 1/2" DOUBLE Y HXHXHXH | 526639 PVC DWV 3" DOUBLE Y HXHXHXH | 526642 PVC DWV 2" X 1 1/2" DOUBLE Y HXHXHXH | 526643 PVC DWV 3" X 1 1/2" DOUBLE Y HXHXHXH |
526644 PVC DWV 3" X 2" DOUBLE Y HXHXHXH | 526860 PVC DWV 6" X 4" RED. COUPLING HXH | 526199 6" x 6" x 4" 45° WYE (HxHxH) | 526175 6" x 6" x 6" 45° WYE (HxHxH) |
526606 8" x 8" x 4" 45° WYE (HxHxH) | 526607 8" x 8" x 6" 45° WYE (HxHxH) | 526560 8" x 8" x 8" 45° WYE (HxHxH) | 526054 6" x 4" Bushing SpxH |
526073 6" x 6" 45° Elbow SpxH | 526125 6" x 6" 90° Elbow HxH | 526126 8" x 8" 90° Elbow HxH | 526175 6" × 6" × 6" 45° Wye HxHxH |
526199 6" × 6" × 4" 45° Wye HxHxH | 526226 8" x 8" 45° Elbow SpxH | 526242 2" x 2" 45° Elbow HxH | 526235 6" x 6" 90° Elbow SpxH |
526245 6" x 6" 45° Elbow HxH | 526246 8" x 8" 45° Elbow HxH | 526255 6" x 6" 22 1/2° Elbow HxH | 526356 6" x 6" Coupling With Pipe Stop (HxH) |
526358 8" x 8" Coupling With Pipe Stop (HxH) | 526377 6" × 6" × 6" TY HxHxH | 526385 6" × 6" × 4" TY HxHxH | 526415 6” Cap H |
526416 8” Cap H | 526446 8" x 4" Bushing (SpxH) | 526447 8" x 6" Bushing (SpxH) | 526550 2” TY SpigotxHxH |
526560 8" x 8" x 8" 45° Wye HxHxH | 526606 8" x 8" x 4" 45° Wye HxHxH | 526607 8" x 8" x 6" 45° Wye HxHxH | Coupling Socket x Socket 526183 10" PVC DWV COUPLING HxH |
Coupling Socket x Socket 526184 12" PVC DWV COUPLING HxH SYSTEM | Elbow 22.5° 526156 8"x22 1/2D PVC DWV ELBOW HxH | Elbow 45° Socket x Socket 526421 10"x45D PVC DWV ELBOW HxH | Elbow 45° Socket x Socket 526422 12"x45D PVC DWV SHORT TURN ELBOW HxH |
Elbow 45° Spigot x Socket 526531 10"x45D PVC DWV SHORT TURN ELBOW SPxH | Elbow 45° Spigot x Socket 526532 12"x45D PVC DWV SHORT TURN ELBOW SPxH | Elbow 90° Socket X socket 526132 10"x90D PVC DWV ELBOW HxH | Elbow 90° Socket X socket 526133 12"x90D PVC DWV ELBOW HxH |
Elbow 90°Spigot X Socket 526114 10"x90D PVC DWV ELBOW SPxH | Elbow 90° Spigot X Socket 526115 12"x90D PVC DWV ELBOW SPxH | Plug 526350 8" PVC DWV C/O W/ PLUG SPxGSKT PLUG | Plug 526357 8" PVC DWV PLUG C/O MPT |
Plug 526355 8" PVC DWV FTG C/O SPxFPT | Reducer Bushing Spigot x Socket 526851 10"x4" PVC DWV FLUSH RED. BUSHING SPxH | Reducer Bushing Spigot x Socket 526852 10"x6" PVC DWV FLUSH RED. BUSHING SPxH | Reducer Bushing Spigot x Socket 526853 10"x8" PVC DWV FLUSH RED. BUSHING SPxH |
Reducer Bushing Spigot x Socket 526854 12"x4" PVC DWV FLUSH RED. BUSHING SPxH | Reducer Bushing Spigot x Socket 526855 12"x6" PVC DWV FLUSH RED. BUSHING SPxH | Reducer Bushing Spigot x Socket 526856 12"x8" PVC DWV FLUSH RED. BUSHING SPxH | Reducer Bushing Spigot x Socket 526857 12"x10" PVC DWV FLUSH RED. BUSHING SPxH |
Reducer Bushing Spigot x Socket 526843 10"x8"x45D PVC DWV WYE HxHxH | Reducer Coupling Socket x Socket 526208 8"x4" PVC DWV REDUCER COUPLING HxH | Reducer Coupling Socket x Socket 526209 8"x6" PVC DWV REDUCER COUPLING HxH | Reducer Coupling Socket x Socket 526212 10"x8" PVC DWV REDUCER COUPLING HxH |
Reducer Coupling Socket x Socket 526215 12"x10" PVC DWV REDUCER COUPLING HxH | Wye 45° Socket x Socket x Socket 526840 10"x45D PVC DWV WYE HxHxH | Wye 45° Socket x Socket x Socket 526841 10"x4"x45D PVC DWV WYE HxHxH | Wye 45° Socket x Socket x Socket 526842 10"x6"x45D PVC DWV WYE HxHxH |
Wye 45° Socket x Socket x Socket 526844 12"x45D PVC DWV WYE HxHxH | Wye 45° Socket x Socket x Socket 526845 12"x4"x45D PVC DWV WYE HxHxH | Wye 45° Socket x Socket x Socket 526846 12"x6"x45D PVC DWV WYE HxHxH | Wye 45° Socket x Socket x Socket 526847 12"x8"x45D PVC DWV WYE HxHxH |
Wye 45° Socket x Socket x Socket 526848 12"x10"x45D PVC DWV WYE HxHxH | XFR PVC Fabricated Fittings – 45° Wye 8” x 4” | XFR PVC Fabricated Fittings – 45° Wye 8” x 6” | XFR PVC Fabricated Fittings – 45° Wye 8” x 8” |
XFR PVC Fabricated Fittings – 45° Wye 10” x 4” | XFR PVC Fabricated Fittings – 45° Wye 10” x 6” | XFR PVC Fabricated Fittings – 45° Wye 10” x 8” | XFR PVC Fabricated Fittings – 45° Wye 10” x 10” |
XFR PVC Fabricated Fittings – 45° Wye 12” x 4” | XFR PVC Fabricated Fittings – 45° Wye 12” x 6” | XFR PVC Fabricated Fittings – 45° Wye 12” x 8” | XFR PVC Fabricated Fittings – 45° Wye 12” x 10” |
XFR PVC Fabricated Fittings – 45° Wye 12” x 12” | XFR PVC Fabricated Fittings – 45° Wye 14” x 4” | XFR PVC Fabricated Fittings – 45° Wye 14” x 6” | XFR PVC Fabricated Fittings – 45° Wye 14” x 8” |
XFR PVC Fabricated Fittings – 45° Wye 14” x 10” | XFR PVC Fabricated Fittings – 45° Wye 14” x 12” | XFR PVC Fabricated Fittings – 45° Wye 14” x 14” | XFR PVC Fabricated Fittings – 45° Wye 16” x 4” |
XFR PVC Fabricated Fittings – 45° Wye 16” x 6” | XFR PVC Fabricated Fittings – 45° Wye 16” x 8” | XFR PVC Fabricated Fittings – 45° Wye 16” x 10” | XFR PVC Fabricated Fittings – 45° Wye 16” x 12” |
XFR PVC Fabricated Fittings – 45° Wye 16” x 14” | XFR PVC Fabricated Fittings – 45° Wye 16” x 16” | XFR PVC Fabricated Fittings – 45° Wye 18” x 4” | XFR PVC Fabricated Fittings – 45° Wye 18” x 6” |
XFR PVC Fabricated Fittings – 45° Wye 18” x 8” | XFR PVC Fabricated Fittings – 45° Wye 18” x 10” | XFR PVC Fabricated Fittings – 45° Wye 18” x 12” | XFR PVC Fabricated Fittings – 45° Wye 18” x 14” |
XFR PVC Fabricated Fittings – 45° Wye 18” x 16” | XFR PVC Fabricated Fittings – 45° Wye 18” x 18” | XFR PVC Fabricated Fittings – Apartment Fitting 3”x3”x3”x1½”x1½” - 526007 | XFR PVC Fabricated Fittings – Cap 8” |
XFR PVC Fabricated Fittings – Cap 10” | XFR PVC Fabricated Fittings – Cap 12” | XFR PVC Fabricated Fittings – Cap 14” | XFR PVC Fabricated Fittings – Coupling 8” |
XFR PVC Fabricated Fittings – Coupling 10” | XFR PVC Fabricated Fittings – Coupling 12” | XFR PVC Fabricated Fittings – Coupling 14” | XFR PVC Fabricated Fittings – Coupling 16” |
XFR PVC Fabricated Fittings – Coupling 18” | XFR PVC Fabricated Fittings – Coupling ¼” Bend / 90° Elbow 8” | XFR PVC Fabricated Fittings – Coupling ¼” Bend / 90° Elbow 10” | XFR PVC Fabricated Fittings – Coupling ¼” Bend / 90° Elbow 12” |
XFR PVC Fabricated Fittings – Coupling ¼” Bend / 90° Elbow 14” | XFR PVC Fabricated Fittings – Coupling ¼” Bend / 90° Elbow 16” | XFR PVC Fabricated Fittings – Coupling ¼” Bend / 90° Elbow 18” | XFR PVC Fabricated Fittings – Coupling 1/8” Bend / 45° Elbow 8” |
XFR PVC Fabricated Fittings – Coupling 1/8” Bend / 45° Elbow 10” | XFR PVC Fabricated Fittings – Coupling 1/8” Bend / 45° Elbow 12” | XFR PVC Fabricated Fittings – Coupling 1/8” Bend / 45° Elbow 14” | XFR PVC Fabricated Fittings – Coupling 1/8” Bend / 45° Elbow 16” |
XFR PVC Fabricated Fittings – Coupling 1/8” Bend / 45° Elbow 18” | XFR PVC Fabricated Fittings – Coupling 1/16” Bend / 22 ½° Elbow 8” | XFR PVC Fabricated Fittings – Coupling 1/16” Bend / 22 ½° Elbow 10” | XFR PVC Fabricated Fittings – Coupling 1/16” Bend / 22 ½° Elbow 12” |
XFR PVC Fabricated Fittings – Coupling 1/16” Bend / 22 ½° Elbow 14” | XFR PVC Fabricated Fittings – Coupling 1/16” Bend / 22 ½° Elbow 18” | XFR PVC Fabricated Fittings – Coupling 1/16” Bend / 22 ½° Elbow 18” | XFR PVC Fabricated Fittings–Double Apartment Fitting 3x3x3x3x1½x1½x1½x1½-526008 |
XFR PVC Fabricated Fittings – Double Wye 8” x 4” | XFR PVC Fabricated Fittings – Double Wye 8” x 6” | XFR PVC Fabricated Fittings – Double Wye 8” x 8” | XFR PVC Fabricated Fittings – Double Wye 10” x 4” |
XFR PVC Fabricated Fittings – Double Wye 10” x 6” | XFR PVC Fabricated Fittings – Double Wye 10” x 8” | XFR PVC Fabricated Fittings – Double Wye 10” x 10” | XFR PVC Fabricated Fittings – Double Wye 12” x 4” |
XFR PVC Fabricated Fittings – Double Wye 12” x 6” | XFR PVC Fabricated Fittings – Double Wye 12” x 8” | XFR PVC Fabricated Fittings – Double Wye 12” x 10” | XFR PVC Fabricated Fittings – Double Wye 12” x 12” |
XFR PVC Fabricated Fittings – Double Wye 14” x 4” | XFR PVC Fabricated Fittings – Double Wye 14” x 6” | XFR PVC Fabricated Fittings – Double Wye 14” x 8” | XFR PVC Fabricated Fittings – Double Wye 14” x 10” |
XFR PVC Fabricated Fittings – Double Wye 14” x 12” | XFR PVC Fabricated Fittings – Double Wye 14” x 14” | XFR PVC Fabricated Fittings – Double Wye 16” x 4” | XFR PVC Fabricated Fittings – Double Wye 16” x 6” |
XFR PVC Fabricated Fittings – Double Wye 16” x 8” | XFR PVC Fabricated Fittings – Double Wye 16” x 10” | XFR PVC Fabricated Fittings – Double Wye 16” x 12” | XFR PVC Fabricated Fittings – Double Wye 16” x 14” |
XFR PVC Fabricated Fittings – Double Wye 16” x 16” | XFR PVC Fabricated Fittings – Double Wye 18” x 4” | XFR PVC Fabricated Fittings – Double Wye 18” x 6” | XFR PVC Fabricated Fittings - Double ° Wye 18” x 8” |
XFR PVC Fabricated Fittings – Double Wye 18” x 10” | XFR PVC Fabricated Fittings – Double Wye 18” x 12” | XFR PVC Fabricated Fittings – Double Wye 18” x 14” | XFR PVC Fabricated Fittings – Double Wye 18” x 16” |
XFR PVC Fabricated Fittings – Double Wye 18” x 18” | XFR PVC Fabricated Fittings – Reducing Bushing 8” x 4” | XFR PVC Fabricated Fittings – Reducing Bushing 8” x 6” | XFR PVC Fabricated Fittings – Reducing Bushing 10” x 4” |
XFR PVC Fabricated Fittings – Reducing Bushing 10” x 6” | XFR PVC Fabricated Fittings – Reducing Bushing 10” x 8” | XFR PVC Fabricated Fittings – Reducing Bushing 12” x 4” | XFR PVC Fabricated Fittings – Reducing Bushing 12” x 6” |
XFR PVC Fabricated Fittings – Reducing Bushing 12” x 8” | XFR PVC Fabricated Fittings – Reducing Bushing 12” x 10” | XFR PVC Fabricated Fittings – Reducing Bushing 14” x 4” | XFR PVC Fabricated Fittings – Reducing Bushing 14” x 6” |
XFR PVC Fabricated Fittings – Reducing Bushing 14” x 8” | XFR PVC Fabricated Fittings – Reducing Bushing 14” x 10” | XFR PVC Fabricated Fittings – Reducing Bushing 14” x 12” | XFR PVC Fabricated Fittings – Reducing Bushing 16” x 4” |
XFR PVC Fabricated Fittings – Reducing Bushing 16” x 6” | XFR PVC Fabricated Fittings – Reducing Bushing 16” x 8” | XFR PVC Fabricated Fittings – Reducing Bushing 16” x 10” | XFR PVC Fabricated Fittings – Reducing Bushing 16” x 12” |
XFR PVC Fabricated Fittings – Reducing Bushing 16” x 14” | XFR PVC Fabricated Fittings – Reducing Bushing 18” x 4” | XFR PVC Fabricated Fittings – Reducing Bushing 18” x 6” | XFR PVC Fabricated Fittings – Reducing Bushing 18” x 8” |
XFR PVC Fabricated Fittings – Reducing Bushing 18” x 10” | XFR PVC Fabricated Fittings – Reducing Bushing 18” x 12” | XFR PVC Fabricated Fittings – Reducing Bushing 18” x 14” | XFR PVC Fabricated Fittings – Reducing Bushing 18” x 16” |
XFR PVC Fabricated Fittings – Tee 8” x 4” | XFR PVC Fabricated Fittings – Tee 8” x 6” | XFR PVC Fabricated Fittings – Tee 8” x 8” | XFR PVC Fabricated Fittings – Tee 10” x 4” |
XFR PVC Fabricated Fittings – Tee 10” x 6” | XFR PVC Fabricated Fittings – Tee 10” x 8” | XFR PVC Fabricated Fittings – Tee 10” x 10” | XFR PVC Fabricated Fittings – Tee 12” x 4” |
XFR PVC Fabricated Fittings – Tee 12” x 6” | XFR PVC Fabricated Fittings – Tee 12” x 8” | XFR PVC Fabricated Fittings – Tee 12” x 10” | XFR PVC Fabricated Fittings – Tee 12” x 12” |
XFR PVC Fabricated Fittings – Tee 14” x 4” | XFR PVC Fabricated Fittings – Tee 14” x 6” | XFR PVC Fabricated Fittings – Tee 14” x 8” | XFR PVC Fabricated Fittings – Tee 14” x 10” |
XFR PVC Fabricated Fittings – Tee 14” x 12” | XFR PVC Fabricated Fittings – Tee 14” x 14” | XFR PVC Fabricated Fittings – Tee 16” x 4” | XFR PVC Fabricated Fittings – Tee 16” x 6” |
XFR PVC Fabricated Fittings – Tee 16” x 8” | XFR PVC Fabricated Fittings – Tee 16” x 10” | XFR PVC Fabricated Fittings – Tee 16” x 12” | XFR PVC Fabricated Fittings – Tee 16” x 14” |
XFR PVC Fabricated Fittings – Tee 16” x 16” | XFR PVC Fabricated Fittings – Tee 18” x 4” | XFR PVC Fabricated Fittings – Tee 18” x 6” | XFR PVC Fabricated Fittings – Tee 18” x 8” |
XFR PVC Fabricated Fittings – Tee 18” x 10” | XFR PVC Fabricated Fittings – Tee 18” x 12” | XFR PVC Fabricated Fittings – Tee 18” x 14” | XFR PVC Fabricated Fittings – Tee 18” x 16” |
XFR PVC Fabricated Fittings – Tee 18” x 18” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 8” x 4” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 8” x 6” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 8” x 8” |
XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 10” x 4” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 10” x 6” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 10” x 8” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 10” x 10” |
XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 12” x 4” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 12” x 6” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 12” x 8” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 12” x 10” |
XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 12” x 12” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 14” x 4” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 14” x 6” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 14” x 8” |
XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 14” x 10” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 14” x 12” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 14” x 14” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 16” x 4” |
XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 16” x 6” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 16” x 8” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 16” x 10” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 16” x 12” |
XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 16” x 14” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 16” x 16” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 18” x 4” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 18” x 6” |
XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 18” x 8” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 18” x 10” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 18” x 12” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 18” x 14” |
XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 18” x 16” | XFR PVC Fabricated Fittings – Tee Wye (Sanitary Tees) 18” x 18” | ||
~ Product is authorized to bear the cNSF Mark. [1] System XFR® PVC fittings have been tested in conjunction with System XFR® pipe only, for use in drain, waste and ventilation applications. [2] FSR and SDC listed values obtained with 10 mm and 0 mm exposed pipe lengths between fittings. [3] Flame Spread Value (FSV) <=25 Smoke Developed Value (SDV) <=50 |
|||
Pipe~ [1] [2] [3] |
PVC |
System XFR |
CAN/ULC S102.2 |
1 1/2" Sch 40 | |||
2" Sch 40 | |||
3" Sch 40 | |||
4" Sch 40 | |||
6" Sch 40 | |||
8" Sch 40 | |||
10" Sch 40 | |||
12" Sch 40 | |||
14" Sch 40 | |||
16" Sch 40 | |||
18" Sch 40 | |||
~ Product is authorized to bear the cNSF Mark. [1] System XFR® PVC fittings have been tested in conjunction with System XFR® pipe only, for use in drain, waste and ventilation applications. [2] FSR and SDC listed values obtained with 10 mm and 0 mm exposed pipe lengths between fittings. [3] Flame Spread Value (FSV) <=25 Smoke Developed Value (SDV) <=50 |
NOTE: Only products bearing the NSF Mark are NSF Certified.
Facility : Toronto, Ontario, Canada
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Fittings~ [1] [2] [3] |
CPVC |
IPEX (Aquarise) |
CAN/ULC S102.2 |
Adapter (IPS S x CTS S) |
|||
359101 3/4" | 359100 1/2" | ||
Adapter (IPS SOC x CTS S) |
|||
359098 3/4" | 359097 1/2" | ||
45° Elbow (Soc x Soc) |
|||
359164 1/2" | 359165 3/4" | 359166 1" | 359167 1 1/4" |
359168 1 1/2" | 359169 2" | 359170 2 1/2" | 359171 3" |
359172 4" | 359173 6" | ||
90° Elbow (Soc x Soc) |
|||
359194 1/2" | 359195 3/4" | 359196 1" | 359197 1 1/4 |
359198 1 1/2" | 359199 2" | 359200 2 1/2" | 359201 3" |
359202 4" | 359203 6" | ||
90° Street Elbow (S x S) |
|||
359175 1/2" | 359176 3/4" | 359177 1" | |
Cap (Soc) |
|||
359109 1/2" | 359110 3/4" | 359111 1" | 359112 1 1/4" |
359113 1 1/2" | 359114 2" | 359115 2 1/2" | 359116 3" |
359107 4" | 359108 6" | ||
Female Adapter, SOC x FPT |
|||
359800 1/2" | 359801 3/4" | 359803 1 1/4" | 359804 1 1/2" |
359805 2" | |||
Female Adapter, SP x FPT |
|||
359820 1/2" | 359821 3/4" | 359822 1" | |
Flange x Socket |
|||
359228 1/2" | 359229 3/4" | 359230 1" | 359231 1 1/4" |
359232 1 1/2" | 359233 2" | 359040 2 1/2" | 359234 2 1/2" |
359041 3" | 359235 3" | 359043 4" | 359236 4" |
359042 6" | 359238 6" | ||
Coupling (Soc x Soc) |
|||
359132 1/2" | 359133 3/4" | 359134 1" | 359135 1 1/4" |
359136 1 1/2" | 359137 2" | 359138 2 1/2" | 359139 3" |
359140 4" | 359141 6" | ||
Male Adapter, SOC x MPT |
|||
359811 1/2" | 359812 3/4" | 359813 1" | 359814 1 1/4" |
359815 1 1/2" | 359816 2" | ||
Male Adapter, SP x MPT |
|||
359823 1/2" | 359824 3/4" | 359825 1" | |
Manifold Tee (¾" SPGx¾" SOC w/One ½" SOC Branches) |
|||
359061 3/4" x 1/2" | |||
Manifold Tee (¾" SPGx¾" SOC w/Two ½" SOC Branches) |
|||
359060 3/4" x 1/2" | |||
Reducer Bushing (Sp x Soc) |
|||
359375 3/4" x 1/2" | 359376 1" x 1/2" | 359377 1" x 3/4" | 359378 1 1/4" x 1/2" |
359379 1 1/4" x 3/4" | 359380 1 1/4" x 1" | 359381 1 1/2" x 1/2" | 359382 1 1/2" x 3/4" |
359383 1 1/2" x 1" | 359384 1 1/2" x 1 1/4" | 359385 2" x 1/2" | 359386 2" x 3/4" |
359387 2" x 1" | 359388 2" x 1 1/4" | 359389 2" x 1 1/2" | 359390 2 1/2" x 3/4" |
359391 2 1/2" x 1" | 359392 2 1/2" x 2" | 359393 3" x 1 1/2" | 359394 3" x 2" |
359395 3" x 2 1/2" | 359428 4" x 1 1 /4" | 359429 4" x 1 1/2" | 359396 4" x 2" |
359430 4" x 2 1/2" | 359397 4" x 3" | 359398 6" x 2" | 359399 6" x 3" |
359400 6" x 4" | |||
Reducer Coupling (Soc x Soc) |
|||
359460 3/4" x 1/2" | 359461 1" x 1/2" | 359462 1" x 3/4" | 359463 1 1/4" x 1" |
359465 1 1/2" x 1" | 359466 1 1/2" x 1 1/4" | 359467 2" x 1" | 359458 2" x 1 1/2" |
359470 3" x 2" | 359459 4" x 2" | 359472 4" x 3" | 359510 6" x 6" x 2" |
359511 6" x 6" x 3" | 359512 6" x 6" x 4" | ||
Reducing Tee (S x S x S) |
|||
359513 3/4" x 1/2" x 3/4" | 359514 3/4" x 1/2" x 1/2" | 359492 3/4" x 3/4" x 1/2" | 359493 1" x 1" x 1/2" |
359494 1" x 1" x 3/4" | 359495 1 1/4" x 1 1/4" x 1" | 359515 1 1/2" x 1 1/2" x 1/2" | 359496 1 1/2" x 1 1/2" x 3/4" |
359497 1 1/2" x 1 1/2" x 1" | 359498 2" x 2" x 1/2" | 359499 2" x 2" x 3/4" | 359500 2" x 2" x 1" |
359501 2" x 2" x 1 1/2" | 359503 2 1/2" x 2 1/2" x 1/2" | 359504 2 1/2" x 2 1/2" x 3/4" | 359505 2 1/2" x 2 1/2" x 1" |
359506 2 1/2" x 2 1/2" x 1 1/4" | 359507 2 1/2" x 2 1/2" x 2" | 359502 3" x 3" x 2" | 359508 4" x 4" x 2" |
359509 4" x 4" x 3" | |||
Tee (Soc x Soc x Soc) |
|||
359481 1/2" | 359482 3/4" | 359483 1" | 359484 1 1/4" |
359485 1 1/2" | 359486 2" | 359487 2 1/2" | 359488 3" |
359489 4" | 359490 6" | ||
Union (S x S) |
|||
359520 1/2" | 359521 3/4" | 359522 1" | 359523 1 1/4" |
359524 1 1/2" | 359525 2" | 359051 3" | 359550 4" |
Van Stone Style Flange 150 lbs. |
|||
359268 3" | 359266 1 1/2" | 359267 2" | 359270 4" |
~ Product is authorized to bear the cNSF Mark. [1] AquaRise pipe and fittings are certified as a system to CAN/ULC S102.2. [2] Flame Spread Value (FSV) <=25 Smoke Developed Value (SDV) <=50 [3] Product may be marked with the "IPEX" trade name only. |
|||
Pipe~ [1] [2] [3] |
CPVC 4120 |
IPEX (Aquarise) |
CAN/ULC S102.2 |
1/2" - 6" SDR 11 | |||
1 1/2" - 6" SDR 21 | |||
~ Product is authorized to bear the cNSF Mark. [1] AquaRise pipe and fittings are certified as a system to CAN/ULC S102.2. [2] Flame Spread Value (FSV) <=25 Smoke Developed Value (SDV) <=50 [3] Product may be marked with the "IPEX" trade name only. |
|||
Fitting Compounds[2] |
CPVC 4120 |
AquaRise |
CAN/ULC S102.2 |
Nominal 2.7 to 20 mm thick | |||
[2] Flame Spread Value (FSV) <=25 Smoke Developed Value (SDV) <=50 |
|||
Pipe Compound[2] |
CPVC 4120 |
AquaRise |
CAN/ULC S102.2 |
Nominal 1.9 to 17 mm thick | |||
[2] Flame Spread Value (FSV) <=25 Smoke Developed Value (SDV) <=50 |
NOTE: Only products bearing the NSF Mark are NSF Certified.
IPEX USA LLC | |
3 Place Du Commerce, Suite 101 | |
Verdun, QC H3E 1H7 | |
Canada | |
514-769-2200 | |
Visit this company's website |
Facility : Ft. Pierce, FL
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Pipe~ [1] [2] |
PVC |
IPEX |
CAN/ULC S102.2 |
1/2" - 12" Sch 40 | |||
1/2" - 8" Sch 80 | |||
~ Product is authorized to bear the cNSF Mark. [1] Approved for a thickness of 3 mm - 14mm. [2] Flame Spread Value (FSV) =10 Smoke Developed Value (SDV) =195 |
|||
Pipe~ [1] [2] |
PVC |
Xirtec PVC |
CAN/ULC S102.2 |
1/2" - 12" Sch 40 | |||
1/2" - 8" Sch 80 | |||
~ Product is authorized to bear the cNSF Mark. [1] Approved for a thickness of 3 mm - 14mm. [2] Flame Spread Value (FSV) =10 Smoke Developed Value (SDV) =195 |
|||
Pipe~ [1] [2] |
PVC |
Silver-Line |
CAN/ULC S102.2 |
1/2" - 12" Sch 40 | |||
1/2" - 8" Sch 80 | |||
~ Product is authorized to bear the cNSF Mark. [1] Approved for a thickness of 3 mm - 14mm. [2] Flame Spread Value (FSV) =10 Smoke Developed Value (SDV) =195 |
Facility : Asheville, NC
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Pipe~ [1] [2] |
PVC |
IPEX |
CAN/ULC S102.2 |
1/2" - 12" Sch 40 | |||
1/2" - 8" Sch 80 | |||
~ Product is authorized to bear the cNSF Mark. [1] Approved for a thickness of 3 mm - 14mm. [2] Flame Spread Value (FSV) =10 Smoke Developed Value (SDV) =195 |
|||
Pipe~ [1] [2] |
PVC |
Xirtec PVC |
CAN/ULC S102.2 |
1/2" - 12" Sch 40 | |||
1/2" - 8" Sch 80 | |||
~ Product is authorized to bear the cNSF Mark. [1] Approved for a thickness of 3 mm - 14mm. [2] Flame Spread Value (FSV) =10 Smoke Developed Value (SDV) =195 |
|||
Pipe~ [1] [2] |
PVC |
RadonX |
CAN/ULC S102.2 |
4" Sch 40 | |||
~ Product is authorized to bear the cNSF Mark. [1] Approved for a thickness of 3 mm - 14mm. [2] Flame Spread Value (FSV) =10 Smoke Developed Value (SDV) =195 |
|||
Pipe~ [1] [2] |
PVC |
Silver-Line |
CAN/ULC S102.2 |
1/2" - 12" Sch 40 | |||
1/2" - 8" Sch 80 | |||
~ Product is authorized to bear the cNSF Mark. [1] Approved for a thickness of 3 mm - 14mm. [2] Flame Spread Value (FSV) =10 Smoke Developed Value (SDV) =195 |
Facility : Pineville, NC
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Fittings~ [1] [2] |
CPVC |
System 636 |
CAN/ULC S102.2 |
45 Elbow H x H |
|||
2" | 3" | 4" | 6" |
8" | 10" | 12" | |
45 Elbow SP x H |
|||
4" | |||
45 Wye H x H x H |
|||
6" x 6" x 4" | 8" x 8" x 4" | 10" x 10" x 4" | 12" x 12" x 4" |
45 Wye H x H x H x H |
|||
6" x 6" x 4" | |||
90 Elbow SP x H |
|||
4" | |||
90 Elbows HxH |
|||
2" | 2" Long | 3" | 3" Long |
4" | 4" Long | 6" | 6" Long |
8" | 8" Long | 10" | 12" |
Coupling H x SP |
|||
2" | 3" | 4" | |
Coupling SP x SP |
|||
2" | 3" | 4" | |
Couplings H x H |
|||
1 1/2" | 2" | 2 1/2" | 3" |
4" | 6" | 8" | 10" |
12" | |||
End Caps |
|||
6" | 8" | 10" | 12" |
Female Adapter |
|||
2" | |||
Plug MPT |
|||
1/2" | |||
Reducer Bushing SP x Barb |
|||
1 1/2" x 1 1/2" | |||
Reducer Bushing SP x FPT |
|||
2" x 1/2" | |||
Reducer Bushings SP x H |
|||
1 1/2" x 1/2" | 2" x 1/2" | 2" x 3/4'' | 2" x 1 1/2" |
3" x 2'' | 3" x 2'' Hex | 3" x 2 1/2" | 4" x 2" |
6" x 4" | 8" x 6" | ||
Reducer Couplings H x H |
|||
3" x 2'' | 4" x 3" | 4" x 6" | |
Tees H x H x 1/2" NPT |
|||
1 1/2" | 2" | 3" | 4" |
Tees H x H x H |
|||
2" | 3" | 3" x 2" | 3" x 3" x 2" |
4" | 4" x 2" | 4" x 4" x 2" | 6" |
6" x 6" x 4" | 6" x 6" x 6" | 8" | 8" x 8" x 6" |
Custom Assemblies |
|||
Bosch 6" x Metric Adapter | Bosch 8" x Metric Adapter | CPVC 3" Tee | CPVC 4" Tee |
CPVC Reducer bushing 8" x 6" | Lochinvar – 2" Flue Connector | Lochinvar – 3" Flue Connector | Lochinvar - Appliance Adaptor 2", 3", 4" |
Viessmann - 2" Adapter Coupling | Viessmann - 3" Adapter Coupling | Viessmann - 4" Adapter Coupling | |
~ Product is authorized to bear the cNSF Mark. [1] System 636 pipe and fittings are certified as a system to CAN/ULC S102.2. [2] Flame Spread Value (FSV) <=25 Smoke Developed Value (SDV) <=50 |
|||
Pipe~ [1] [2] |
CPVC |
System 636 |
CAN/ULC S102.2 |
1 1/2" | 2" | 2 1/2" | 3" |
4" | 6" | 8" | 10" |
12" | |||
~ Product is authorized to bear the cNSF Mark. [1] System 636 pipe and fittings are certified as a system to CAN/ULC S102.2. [2] Flame Spread Value (FSV) <=25 Smoke Developed Value (SDV) <=50 |
Facility : Lawton, OK
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Pipe~ [1] [2] |
PVC |
IPEX |
CAN/ULC S102.2 |
1/2" - 12" Sch 40 | |||
1/2" - 8" Sch 80 | |||
~ Product is authorized to bear the cNSF Mark. [1] Approved for a thickness of 3 mm - 14mm. [2] Flame Spread Value (FSV) =10 Smoke Developed Value (SDV) =195 |
|||
Pipe~ [1] [2] |
PVC |
Xirtec PVC |
CAN/ULC S102.2 |
1/2" - 12" Sch 40 | |||
1/2" - 8" Sch 80 | |||
~ Product is authorized to bear the cNSF Mark. [1] Approved for a thickness of 3 mm - 14mm. [2] Flame Spread Value (FSV) =10 Smoke Developed Value (SDV) =195 |
|||
Pipe~ [1] [2] |
PVC |
Silver-Line |
CAN/ULC S102.2 |
1/2" - 12" Sch 40 | |||
1/2" - 8" Sch 80 | |||
~ Product is authorized to bear the cNSF Mark. [1] Approved for a thickness of 3 mm - 14mm. [2] Flame Spread Value (FSV) =10 Smoke Developed Value (SDV) =195 |
J-M Manufacturing Co., Inc. DBA JM Eagle | |
9 Peach Tree Hill Road | |
Livingston, NJ 07039 | |
United States | |
310-693-8200 | |
Visit this company's website |
Facility : # 4 Columbia, MO
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe# + [G] |
PVCO |
J-M Manufacturing |
UL 1285 |
PC 235: 6", 8", 10", 12" | |||
PC 305: 6", 8" | |||
# This product may be marked with an alternate trade name: J-M Manufacturing, PW Eagle, [JMM Logo] or [JM Eagle Logo]. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
NOTE: Only products bearing the NSF Mark are Certified.
Facility : # 6 Fontana, CA
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe# + [G] |
PVCO |
J-M Manufacturing |
UL 1285 |
PC 305: 6", 8", 10", 12", 14", 16", 18", 20", 24" | |||
PC 235: 6", 8", 10", 12", 14", 16", 18", 20", 24" | |||
# This product may be marked with an alternate trade name: J-M Manufacturing, PW Eagle, [JMM Logo] or [JM Eagle Logo]. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : # 9 Magnolia, AR
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe+ ^ |
PE 4710 |
J-M Manufacturing |
FM 1613 |
PC 335: IPS 4" - 12" DR 7 | |||
PC 250: IPS 4" - 12" DR 9 | |||
PC 200: IPS 4" - 12" DR 11 | |||
PC 335: DIOD 4" - 12" DR 7 | |||
PC 250: DIOD 4" - 12" DR 9 | |||
PC 200: DIOD 4" - 12" DR 11 | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ^ This product may be marked with an alternate trade name: JM Eagle, [JM Eagle Logo] and/or [JMM Logo]. |
Facility : # 17 Tulsa, OK
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe+ ^ |
PE 4710 |
J-M Manufacturing |
FM 1613 |
PC 335: IPS 4" - 24" DR 7 | |||
PC 250: IPS 4" - 24" DR 9 | |||
PC 200: IPS 4" - 24" DR 11 | |||
PC 335: DIOD 4" - 24" DR 7 | |||
PC 250: DIOD 4" - 24" DR 9 | |||
PC 200: DIOD 4" - 24" DR 11 | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ^ This product may be marked with an alternate trade name: JM Eagle, [JM Eagle Logo] and/or [JMM Logo]. |
Facility : # 19 Wharton, TX
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe# + [G] |
PVCO |
J-M Manufacturing |
UL 1285 |
PC 165: 16" | |||
PC 235: 6", 8", 10", 12" | |||
PC 305: 6", 8" | |||
# This product may be marked with an alternate trade name: J-M Manufacturing, PW Eagle, [JMM Logo] or [JM Eagle Logo]. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
NOTE: Only products bearing the NSF Mark are Certified.
John L Schultz Ltd. | |
1723 55é Avenue | |
Dorval, QC H9P 2W3 | |
Canada | |
800-363-6240 |
Facility : Guangdong, China
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing# $ * [1] [2] |
PEX |
aqua-dynamic |
ASTM E84 |
3/8", 1/2" - 2" | |||
# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation instructions. The 3/8" tubing is not insulated. $ Certified for blue, natural, red, and white without oxygen barrier. * Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] ASTM E84, 1/2'' - 2'' The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation instructions. The 3/8" tubing is not insulated. [2] Flame Spread Index <= 25 Smoke Developed Index <= 50 |
|||
Tubing$ & [2] [3] |
PEX |
aqua-dynamic |
CAN/ULC S102.2 |
3/8", 1/2" - 2" | |||
$ Certified for blue, natural, red, and white without oxygen barrier. & 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50]. 1/2" - 2" tubing (with insulation), Flame Spread Index and Smoke Developed Index based on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. [2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [3] 3/8" Tubing (without insulation) Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. 1/2" through 2" Tubing (with insulation) Flame Spread Rating and Smoke Developed Classification based on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. |
|||
Tubing[4] [5] |
PEX |
aqua-dynamic |
ASTM E84 |
3/8" - 2"[2] | |||
[2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [4] Certified for red and white PEX 5106 monowall pipe. [5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation instructions. Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
|||
Tubing[4] [6] |
PEX |
aqua-dynamic |
CAN/ULC S102.2 |
3/8" - 2"[2] | |||
[2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [4] Certified for red and white PEX 5106 monowall pipe. [6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. |
|||
Tubing[7] [8] |
PEX |
aqua-dynamic |
ASTM E84 |
3/8" - 1"[2] | |||
[2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [7] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier pipe. [8] The Flame Spread Index and Smoke Developed Index are based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation instructions (all listed construction/color/size combinations greater than or equal to 3/8" in diameter). Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
|||
Tubing[7] [9] |
PEX |
aqua-dynamic |
CAN/ULC S102.2 |
3/8" - 1"[2] | |||
[2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [7] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier pipe. [9] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's installation instructions (all listed construction/color/size combinations greater than or equal to 3/8" in diameter). Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. |
|||
Tubing[5] [10] |
PEX |
aqua-dynamic PEX-A |
ASTM E84 |
1/8" - 3"[2] | |||
[2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation instructions. Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [10] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only. |
|||
Tubing[6] [10] |
PEX |
aqua-dynamic PEX-A |
CAN/ULC S102.2 |
1/8" - 3"[2] | |||
[2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. [10] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only. |
|||
Tubing[5] [11] |
PEX |
aqua-dynamic PEX-A |
ASTM E84 |
1/8" - 3"[2] | |||
[2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation instructions. Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [11] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red, white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. |
|||
Tubing[6] [11] |
PEX |
aqua-dynamic PEX-A |
CAN/ULC S102.2 |
1/8" - 3"[2] | |||
[2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. [11] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red, white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. |
Mexichem Colombia SAS | |
Autopista Sur No. 71-75 | |
Bogota | |
Colombia | |
57 1 782 5000 |
Facility : Bogota, Colombia
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing* ^ |
CPVC |
Tuberia Presion HotPro CPVC |
ASTM E84 |
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. ^ Flame Spread Index <= 25, Smoke Developed Index <= 50 |
MrPEX Systems (a division of Safelink Systems, Inc.) | |
14799 Jackal Street NW | |
Suite 100 | |
Ramsey, MN 55303 | |
United States | |
800-716-3406 | |
952-440-7704 |
Facility : Ulricehamn, Sweden
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing§ ** [1] |
PEX |
Mr. PEX (3-layer and 4-layer Tubing) |
ASTM E84 |
1/2", 5/8", 3/4" |
|||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. ** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25 Smoke Developed Index <= 50 |
National Pipe & Plastics, Inc. | |
One North Page Avenue | |
Endicott, NY 13760 | |
United States | |
800-836-4350 | |
607-729-9381 | |
Visit this company's website |
Facility : Endicott, NY
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe |
PVC |
Dura-Blue |
UL 1285 |
PC 305 4",6",8", 10", 12", 14", 16", 18", 20", 24" DR 14 | |||
PC 235 4",6",8", 10", 12", 14", 16", 18", 20", 24" DR 18 | |||
PC 200 14", 16", 18", 20", 24" DR 21 | |||
PC 165 4",6",8", 10", 12", 14", 16", 18", 20", 24" DR 25 | |||
PC 125 14", 16", 18", 20", 24" DR 32.5 | |||
Pipe |
PVC |
National |
FM 1612 |
PC 250: 4", 6", 8", 10", 12" DR 14 | |||
PC 185: 4", 6", 8", 10", 12" DR 18 |
Facility : Colfax, NC
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe |
PVC |
Dura-Blue |
UL 1285 |
PC305 4",6", 8", 10", 12", 14", 16", 18", 20", 24" DR 14 | |||
PC235 4",6", 8", 10", 12", 14", 16", 18", 20", 24" DR 18 | |||
PC200 14", 16", 18", 20", 24" DR 21 | |||
PC165 4",6", 8", 10", 12", 14", 16", 18", 20", 24" DR 25 | |||
PC125 14", 16", 18", 20", 24" DR 32.5 | |||
Pipe |
PVC |
National |
FM 1612 |
PC 250: 4", 6", 8", 10", 12" DR 14 | |||
PC 185: 4", 6", 8", 10", 12" DR 18 |
PPI America Inc. | |
1440 Renaissance Drive | |
Suite 430 | |
Park Ridge, IL 60068 | |
United States | |
847-430-4477 | |
Visit this company's website |
Facility : # 1 Korea
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Fittings# |
MLTPL |
iPVC fitting |
UL 1285 |
PC 235: 4", 6", 8" | |||
PC 305: 4", 6", 8" | |||
# Certified for PC 235 & PC 305 for the following configurations: iPVC Fitting-a Coupling (Socket) - 4", 6", & 8" 11.25° Elbow - 4", 6", & 8" 22.5° Elbow - 4", 6", & 8" 45° Elbow - 4", 6", & 8" 90° Elbow - 4", 6", & 8" Reducer Socket - 6" x 4", 8" x 4", & 8" x 6" Tee - 4", 6", 8", 6" x 4", 8" x 4", & 8" x 6" Flange socket - 6" & 8" iPVC Fitting Coupling(Socket) - 6", & 8" Repair Coupling(Socket) - 6", & 8" 11.25 Elbow - 6", & 8" 22.5 Elbow - 6", & 8" 45 Elbow - 6", & 8" 90 Elbow - 6", & 8" Reducer Socket - 8" x 6" Tee - 6", 8", & 8" x 6" Flange Tee - 6", 8", 6" x 4", 8" x 6", & 8" x 4" Flange socket - 6", & 8" |
|||
Fittings# |
MLTPL |
iPVC fitting-a |
UL 1285 |
# Certified for PC 235 & PC 305 for the following configurations: iPVC Fitting-a Coupling (Socket) - 4", 6", & 8" 11.25° Elbow - 4", 6", & 8" 22.5° Elbow - 4", 6", & 8" 45° Elbow - 4", 6", & 8" 90° Elbow - 4", 6", & 8" Reducer Socket - 6" x 4", 8" x 4", & 8" x 6" Tee - 4", 6", 8", 6" x 4", 8" x 4", & 8" x 6" Flange socket - 6" & 8" iPVC Fitting Coupling(Socket) - 6", & 8" Repair Coupling(Socket) - 6", & 8" 11.25 Elbow - 6", & 8" 22.5 Elbow - 6", & 8" 45 Elbow - 6", & 8" 90 Elbow - 6", & 8" Reducer Socket - 8" x 6" Tee - 6", 8", & 8" x 6" Flange Tee - 6", 8", 6" x 4", 8" x 6", & 8" x 4" Flange socket - 6", & 8" |
|||
Pipe |
PVC |
iPVC Water Pipe |
UL 1285 |
PC 235: 4" - 18" | |||
PC 305: 4" - 16" | |||
Pipe |
PVC |
Pyungwha PVC Pipe |
UL 1285 |
PC 235: 4" - 16" | |||
PC 305: 4" - 16" | |||
Pipe |
PVC |
PVC Water Pipe |
UL 1285 |
PC 235: 4" - 16" | |||
PC 305: 4" - 16" | |||
Pipe+ |
PVC |
iPVC Water Pipe |
FM 1612 |
14" - 16" DR 14 PC 305 and DR 18 PC 235 | |||
4" - 12" DR 14 PC 250 and DR 18 PC 185 | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
|||
Pipe+ |
PVC |
Pyungwha PVC Pipe |
FM 1612 |
14" - 16" DR 14 PC 305 and DR 18 PC 235 | |||
4" - 12" DR 14 PC 250 and DR 18 PC 185 | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
|||
Pipe+ |
PVC |
PVC Water Pipe |
FM 1612 |
14" - 16" DR 14 PC 305 and DR 18 PC 235 | |||
4" - 12" DR 14 PC 250 and DR 18 PC 185 | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
PPI PIPE Co., Ltd. | |
1085-11, Beodeul-ro, Jangan-myeon | |
Hwaseong-si, Gyeonggi-do 445-941 | |
Korea, Republic of | |
82 31 359 0082 | |
Visit this company's website |
Facility : # 1 Gyeonggi-do, Republic of Korea
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Fittings# |
MLTPL |
iPVC fitting |
UL 1285 |
PC 235: 4", 6", 8" | |||
PC 305: 4", 6", 8" | |||
# Certified for PC 235 & PC 305 for the following configurations: iPVC Fitting-a Coupling (Socket) - 4", 6", & 8" 11.25° Elbow - 4", 6", & 8" 22.5° Elbow - 4", 6", & 8" 45° Elbow - 4", 6", & 8" 90° Elbow - 4", 6", & 8" Reducer Socket - 6" x 4", 8" x 4", & 8" x 6" Tee - 4", 6", 8", 6" x 4", 8" x 4", & 8" x 6" Flange socket - 6" & 8" iPVC Fitting Coupling(Socket) - 6", & 8" Repair Coupling(Socket) - 6", & 8" 11.25 Elbow - 6", & 8" 22.5 Elbow - 6", & 8" 45 Elbow - 6", & 8" 90 Elbow - 6", & 8" Reducer Socket - 8" x 6" Tee - 6", 8", & 8" x 6" Flange Tee - 6", 8", 6" x 4", 8" x 6", & 8" x 4" Flange socket - 6", & 8" |
|||
Fittings# |
MLTPL |
iPVC fitting-a |
UL 1285 |
# Certified for PC 235 & PC 305 for the following configurations: iPVC Fitting-a Coupling (Socket) - 4", 6", & 8" 11.25° Elbow - 4", 6", & 8" 22.5° Elbow - 4", 6", & 8" 45° Elbow - 4", 6", & 8" 90° Elbow - 4", 6", & 8" Reducer Socket - 6" x 4", 8" x 4", & 8" x 6" Tee - 4", 6", 8", 6" x 4", 8" x 4", & 8" x 6" Flange socket - 6" & 8" iPVC Fitting Coupling(Socket) - 6", & 8" Repair Coupling(Socket) - 6", & 8" 11.25 Elbow - 6", & 8" 22.5 Elbow - 6", & 8" 45 Elbow - 6", & 8" 90 Elbow - 6", & 8" Reducer Socket - 8" x 6" Tee - 6", 8", & 8" x 6" Flange Tee - 6", 8", 6" x 4", 8" x 6", & 8" x 4" Flange socket - 6", & 8" |
|||
Pipe |
PVC |
iPVC Water Pipe |
UL 1285 |
PC 235: 4" - 18" | |||
PC 305: 4" - 16" | |||
Pipe+ |
PVC |
iPVC Water Pipe |
FM 1612 |
14" - 16" DR 14 PC 305 and DR 18 PC 235 | |||
4" - 12" DR 14 PC 250 and DR 18 PC 185 | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
|||
Pipe |
PVC |
Pyungwha PVC Pipe |
UL 1285 |
PC 235: 4" - 16" | |||
PC 305: 4" - 16" | |||
Pipe+ |
PVC |
Pyungwha PVC Pipe |
FM 1612 |
14" - 16" DR 14 PC 305 and DR 18 PC 235 | |||
4" - 12" DR 14 PC 250 and DR 18 PC 185 | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
|||
Pipe |
PVC |
PVC Water Pipe |
UL 1285 |
PC 235: 4" - 16" | |||
PC 305: 4" - 16" | |||
Pipe+ |
PVC |
PVC Water Pipe |
FM 1612 |
14" - 16" DR 14 PC 305 and DR 18 PC 235 | |||
4" - 12" DR 14 PC 250 and DR 18 PC 185 | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
REHAU Construction LLC | |
1501 Edwards Ferry Road, N.E. | |
Leesburg, VA 20176 | |
United States | |
800-247-9445 | |
703-777-5255 | |
Visit this company's website |
Facility : # 1 Germany
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing[3] [4] |
PEX |
Raupex® White UV Shield |
CAN/ULC S102.2 |
1/2" - 2" | |||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. [4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50]. |
|||
Tubing[3] [4] |
PEX |
Raupex® Red UV Shield |
CAN/ULC S102.2 |
1/2" - 2" | |||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. [4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50]. |
|||
Tubing* [1] |
PEX |
Municipex® |
ASTM E84 |
3/4" - 2" | |||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing*** [1] |
PEX |
Municipex® |
ASTM E84 |
3/4" - 2" | |||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing[2] [3] |
PEX |
Municipex® |
CAN/ULC S102.2 |
3/4" - 2" | |||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation instructions. [3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing* [1] |
PEX |
Raupex® O2 Barrier |
ASTM E84 |
1/2" - 2" | |||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing** [1] |
PEX |
Raupex® O2 Barrier |
ASTM E84 |
<= 1/2" | |||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing[3] |
PEX |
Raupex® O2 Barrier |
CAN/ULC S102.2 |
<= 1/2" | |||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing[2] [3] |
PEX |
Raupex® O2 Barrier |
CAN/ULC S102.2 |
5/8" - 2" | |||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation instructions. [3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing* [1] |
PEX |
Raupex® |
ASTM E84 |
1/2" - 2" | |||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing** [1] |
PEX |
Raupex® |
ASTM E84 |
<= 3/4" | |||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing*** [1] |
PEX |
Raupex® |
ASTM E84 |
3/4" - 2" | |||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing[3] |
PEX |
Raupex® |
CAN/ULC S102.2 |
<= 1/2" | |||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing[2] [3] |
PEX |
Raupex® |
CAN/ULC S102.2 |
1/2" - 2" | |||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation instructions. [3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing* [1] |
PEX |
Raupex® Blue UV Shield |
ASTM E84 |
1/2" - 2" | |||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing** [1] |
PEX |
Raupex® Blue UV Shield |
ASTM E84 |
<= 3/4" | |||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing*** [1] |
PEX |
Raupex® Blue UV Shield |
ASTM E84 |
3/4" - 2" | |||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing[1] ***** |
PEX |
Raupex® Blue UV Shield |
ASTM E84 |
1/2" - 2" | |||
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50. ***** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
|||
Tubing[3] |
PEX |
Raupex® Blue UV Shield |
CAN/ULC S102.2 |
<= 1/2" | |||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing[2] [3] |
PEX |
Raupex® Blue UV Shield |
CAN/ULC S102.2 |
1/2" - 2" | |||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation instructions. [3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing* [1] |
PEX |
Raupex® Red UV Shield |
ASTM E84 |
1/2" - 2" | |||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing[3] [4] |
PEX |
Raupex® Blue UV Shield |
CAN/ULC S102.2 |
1/2" - 2" | |||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. [4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50]. |
|||
Tubing** [1] |
PEX |
Raupex® Red UV Shield |
ASTM E84 |
<= 3/4" | |||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing*** [1] |
PEX |
Raupex® Red UV Shield |
ASTM E84 |
3/4" - 2" | |||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing[1] ***** |
PEX |
Raupex® Red UV Shield |
ASTM E84 |
1/2" - 2" | |||
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50. ***** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
|||
Tubing[3] |
PEX |
Raupex® Red UV Shield |
CAN/ULC S102.2 |
<= 1/2" | |||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing[2] [3] |
PEX |
Raupex® Red UV Shield |
CAN/ULC S102.2 |
1/2" - 2" | |||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation instructions. [3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing* [1] |
PEX |
Raupex® White UV Shield |
ASTM E84 |
1/2" - 2" | |||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing** [1] |
PEX |
Raupex® White UV Shield |
ASTM E84 |
<= 3/4" | |||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing*** [1] |
PEX |
Raupex® White UV Shield |
ASTM E84 |
3/4" - 2" | |||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing[1] ***** |
PEX |
Raupex® White UV Shield |
ASTM E84 |
1/2" - 2" | |||
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50. ***** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
|||
Tubing[3] |
PEX |
Raupex® White UV Shield |
CAN/ULC S102.2 |
<= 1/2" | |||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing[2] [3] |
PEX |
Raupex® White UV Shield |
CAN/ULC S102.2 |
1/2" - 2" | |||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation instructions. [3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing[2] [3] |
PEX |
RAUGEO |
CAN/ULC S102.2 |
1/2" - 2" | |||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation instructions. [3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
Facility : # 7 USA
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing* [1] |
PEX |
Municipex® |
ASTM E84 |
3/4" - 2" | |||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing*** [1] |
PEX |
Municipex® |
ASTM E84 |
3/4" - 2" | |||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing[2] [3] |
PEX |
Municipex® |
CAN/ULC S102.2 |
3/4" - 2" | |||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation instructions. [3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing* [1] |
PEX |
Municipex® Reclaim |
ASTM E84 |
3/4" - 2" | |||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing*** [1] |
PEX |
Municipex® Reclaim |
ASTM E84 |
3/4" - 2" | |||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing[2] [3] |
PEX |
Municipex® Reclaim |
CAN/ULC S102.2 |
3/4" - 2" | |||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation instructions. [3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing** [1] |
PEX |
Raupex® O2 Barrier |
ASTM E84 |
<= 1/2" | |||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing* [1] |
PEX |
Raupex® O2 Barrier |
ASTM E84 |
5/8" - 2" | |||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing[3] |
PEX |
Raupex® O2 Barrier |
CAN/ULC S102.2 |
<= 1/2" | |||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing[2] [3] |
PEX |
Raupex® O2 Barrier |
CAN/ULC S102.2 |
5/8" - 2" | |||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation instructions. [3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing** [1] |
PEX |
Raupex® |
ASTM E84 |
<= 3/4" | |||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing* [1] |
PEX |
Raupex® |
ASTM E84 |
5/8" - 2" | |||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing*** [1] |
PEX |
Raupex® |
ASTM E84 |
3/4" - 2" | |||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing[3] |
PEX |
Raupex® |
CAN/ULC S102.2 |
<= 1/2" | |||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing[2] [3] |
PEX |
Raupex® |
CAN/ULC S102.2 |
5/8" - 2" | |||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation instructions. [3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing** [1] |
PEX |
Raupex® Blue UV Shield |
ASTM E84 |
<= 3/4" | |||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing* [1] |
PEX |
Raupex® Blue UV Shield |
ASTM E84 |
5/8" - 2" | |||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing*** [1] |
PEX |
Raupex® Blue UV Shield |
ASTM E84 |
3/4" - 2" | |||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing[1] **** |
PEX |
Raupex® Blue UV Shield |
ASTM E84 |
1/2" - 2" | |||
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50. **** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
|||
Tubing[3] |
PEX |
Raupex® Blue UV Shield |
CAN/ULC S102.2 |
<= 1/2" | |||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing[2] [3] |
PEX |
Raupex® Blue UV Shield |
CAN/ULC S102.2 |
5/8" - 2" | |||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation instructions. [3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing[3] [4] |
PEX |
Raupex® Blue UV Shield |
CAN/ULC S102.2 |
1/2" - 2" | |||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. [4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50]. |
|||
Tubing** [1] |
PEX |
Raupex® Red UV Shield |
ASTM E84 |
<= 3/4" | |||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing* [1] |
PEX |
Raupex® Red UV Shield |
ASTM E84 |
5/8" - 2" | |||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing*** [1] |
PEX |
Raupex® Red UV Shield |
ASTM E84 |
3/4" - 2" | |||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing[1] **** |
PEX |
Raupex® Red UV Shield |
ASTM E84 |
1/2" - 2" | |||
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50. **** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
|||
Tubing[3] |
PEX |
Raupex® Red UV Shield |
CAN/ULC S102.2 |
<= 1/2" | |||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing[2] [3] |
PEX |
Raupex® Red UV Shield |
CAN/ULC S102.2 |
5/8" - 2" | |||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation instructions. [3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing[3] [4] |
PEX |
Raupex® Red UV Shield |
CAN/ULC S102.2 |
1/2" - 2" | |||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. [4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50]. |
|||
Tubing** [1] |
PEX |
Raupex® White UV Shield |
ASTM E84 |
<= 3/4" | |||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing* [1] |
PEX |
Raupex® White UV Shield |
ASTM E84 |
5/8" - 2" | |||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing*** [1] |
PEX |
Raupex® White UV Shield |
ASTM E84 |
3/4" - 2" | |||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
|||
Tubing[1] **** |
PEX |
Raupex® White UV Shield |
ASTM E84 |
1/2" - 2" | |||
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50. **** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
|||
Tubing[3] |
PEX |
Raupex® White UV Shield |
CAN/ULC S102.2 |
<= 1/2" | |||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing[2] [3] |
PEX |
Raupex® White UV Shield |
CAN/ULC S102.2 |
5/8" - 2" | |||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation instructions. [3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
|||
Tubing[3] [4] |
PEX |
Raupex® White UV Shield |
CAN/ULC S102.2 |
1/2" - 2" | |||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. [4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50]. |
|||
Tubing[2] [3] |
PEX |
RAUGEO |
CAN/ULC S102.2 |
3/4" - 2" | |||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation instructions. [3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
Fire Sprinkler Pipe and Fitting Systems
Product Type | Material Type | Trade Name | Product Standard |
Pipe and Fitting System% ** [G] |
MLTPL |
FIREPEX™ Residential Fire Sprinkler Systems |
ANSI/CAN/UL 1821 |
90 Degree Elbow |
|||
3/4" x 3/4" (F209E66) | 1" x 1" (F209E88) | 1 1/4" x 1 1/4" (F20E10) | |
EVERLOC+ LF 45 DEG Elbow |
|||
1 1/2" x 1 1/2" (425021) | 2" x 2" (425022) | ||
EVERLOC+ LF Adapter |
|||
1/2" x 1/2" CF (317184) | 3/4" x 3/4" MPT (317172) | 3/4" x 3/4" FPT (317182) | 3/4" x 3/4" CM (317186) |
3/4" x 3/4" CF (317187) (499797) | 3/4" x 1" MPT (317177) | 3/4" x 1" CF (317189) | 1" x 3/4" MPT (323708) |
1" x 3/4" FPT (329227) | 1" x 1" MPT (317178) | 1" x 1" FPT (317183) | 1" x 1" CM (317190) |
1" x 1" CF (317191) (499800) | 1 1/4" x 1 1/4" MPT (317179) | 1 1/4" x 1 1/4" CM (317192) | 1 1/4" x 1 1/4" CF (317193) |
1 1/2" x 1 1/2" MPT (317180) | 1 1/2" x 1 1/2" CM (317194) | 1 1/2" x 2" CM or 1 1/2" CF (317195) | 2" x 2" MPT (317181) |
2" x 2" CM (317196) | 2" x 2" CF (317197) | ||
EVERLOC+ LF Coupling |
|||
1-1/4" x 3/4" (425026) | 1-1/2" x 3/4" (425028) | 2" x 3/4" (425031) | 2" x 1" (317139) |
2" x 1 1/4" (317140) | 2" x 1 1/2" (317141) | ||
EVERLOC+ LF Elbows |
|||
3/4" x 3/4" CM (317166) | 3/4" (317167) | 3/4" x 3/4" MPT (317169) | 3/4" x 3/4" FPT (422006) |
3/4"x 3/4" MPT (425476) | 1" x 1" FPT (422007) | ||
EVERLOC+ LF Tees |
|||
1 1/4" x 1" x 3/4" (424989) | 1 1/4" x 1 1/4" x 1/2" (424991) | 1 1/4" x 1 1/4" x 3/4" (322832) | 1 1/2" x 1 1/4" x 1" (317153) |
2" x 1 1/2" x 1 1/4" (317161) | 1 1/2" x 1 1/4" x 1 1/2" (317145) | 2" x 1 1/2" x 1 1/2" (317155) | 1 1/2" x 1 1/2" x 3/4" (322833) |
2" x 1 1/2" x 2" (317147) | 1 1/2" x 1 1/2" x 1/2" (425024) | 1 1/2" x 1 1/4" x 3/4" (425025) | 1 1/2" x 1" x 3/4" (424992) |
2" x 1 1/4" x 2" (317146) | 2" x 2" x 3/4" (322834) | 2" x 1 1/2" x 1" (317156) | 2" x 1 1/2" x 3/4" (424994) |
2" x 2" x 1/2" (424995) | |||
EVERLOC+ Manifold Sweat Adapter |
|||
3/4" X 1" CF (326712) | 1" X 1" CM (326713) | ||
EVERLOC+ Polymer 45° Elbow |
|||
2” x 2” | 1 ½” x 1 ½” | ||
EVERLOC+ Polymer Coupling |
|||
1 ¼” x ¾” (435718) | 1 ½” x 1 ¼” (435704) | 1 ½” x ¾” (435705) | 2” x 1 ¼” |
2” x 1 ½” (435706) | 2” x 1” | ||
EVERLOC+P Coupling |
|||
3/4" x 3/4" (104825) | 1" x 3/4" (104831) | 1" x 1" (104826) | 1 1/4" x 1" (104832) |
1 1/4" x 1 1/4" (104827) | 1 1/2" x 1" (104833) | 1 1/2" x 1 1/2" (104828) | 2" x 2" (104829) |
EVERLOC+P Elbow |
|||
3/4" x 3/4" (104860) | 1" x 1" (104861) | 1 1/4" x 1 1/4" (104862) | 1 1/2" x 1 1/2" (104863) |
2" x 2" (104864) | |||
EVERLOC+P Plug |
|||
3/4" (104857) | 1" (104858) | 1 1/4" (317158) | 1 1/2" (317159) |
2" (317160) | |||
EVERLOC+P Tee |
|||
3/4" x 1/2" x 3/4" (104841) | 3/4" x 3/4" x 3/4" (104836) | 3/4" x 3/4" x 1" (104855) | 1" x 3/4" x 3/4" (104852) |
1" x 3/4" x 1" (104842) | 1" x 1" x 1" (104837) | 1 1/4" x 1" x 1" (104853) | 1 1/4" x 1 1/4" x 1 1/4" (104838) |
1 1/4" x 1 1/4" x 1" (104847) | 1 1/2" x 1 1/2" x 1" (104848) | 1 1/2" x 1 1/2" x 1 1/2" (104839) | 2" x 2" x 1" (104849) |
2" x 2" x 2" (104840) | |||
EVERLOC+Sleeves |
|||
3/4" (104818) | 1" (104819) | 1 1/4" (104820) | 1 1/2" (104821) |
2" (104822) | |||
Everloc+ Polymer Tee |
|||
1 ¼” x 1” x ¾” | 2” x 2” x 1 ¼” (435714) | 1 ¼” x 1 ¼” x ½” (435703) | 1 ½” x 1” x ¾” |
1 ½” x 1” x 1” (435719) | 1 ½” x 1 ½” x 1 ¼” (435713) | 2” x 1 ½” x ¾” | 2” x 2” x 1 ½” (435710) |
1 ½” x 1” 1 ½” (435709) | 1 ½” x 1 ¼” x ¾” (435711) | 2” x 1 ½” x 1” | 2” x 1 ½” x 1 ¼” |
1" x ¾” x ½” (435701) | 1 ¼” x ¾” x ¾” (435715) | 1 ½” x 1 ¼” x 1” | 1 ½” x 1 ¼” x 1 ½” |
2” x 1 ½” x 1 ½” | 2” x 2” x ½” | 1" x ½” x 1" (435809) | 1 ½” x ¾” x 1 ½” (435716) |
1 ½” x 1 ¼” x 1 ¼” (435720) | 2” x 1 ¼” x 2” | 2” x 1 ½” x 2” | 1 ¼” x ¾” x 1 ¼” (435717) |
1 ¼” x 1 ¼” x ¾” (435700) | 1 ½” x 1 ½” x ½” (435707) | 1 ½” x 1 ½” x ¾” (435702) | 2” x 2” x ¾” (435721) |
1 ¼” x 1” x 1 ¼” (435712) | |||
Everloc+ Stub Ell |
|||
3/4" 8" (418668) (499364) | 3/4" 8" with mounting plate (329229) (499307) | 1" 8" (499365) | |
Male Threaded Adapter |
|||
3/4" x 3/4" (F96E66) | 1" x 1" (F96E88) | 1 1/4" x 1 1/4" (F96E1010) | |
Plug |
|||
3/4" F2080 (F103E6) | 1" F2080 (F103E8) | 1 1/4" F2080 (F103E10) | |
Reducing Coupling |
|||
3/4" x 1/2" (F95E64) | 1 X 3/4" (F95E86) | 1 1/4" X 1" (F95E108) | |
Sprinkler Elbows |
|||
3/4" x 1/2" FPT (422004) | 1" x 1/2" FPT (422005) | ||
Sprinkler Tees |
|||
3/4" x 3/4" x 1/2" FPT (421744) | 1" x 1" x 1/2" FPT (421878) | ||
Tees |
|||
3/4" x 1/2" x 1/2" [F208E644] | 3/4" x 1/2" x 3/4" [F208E646] | 3/4" x 3/4" x 1/2" [F208E664] | 3/4" x 3/4" x 3/4" [F208E666] |
1" x 1" x 3/4" [F208E886] | 1" x 1" x 1" [F208E888] | 1 1/4" x 3/4" x 1" [F208E1068] | 1 1/4" x 1 1/4" x 3/4" [F208E10106] |
1 1/4" x 1 1/4" x 1" [F208E10108] | |||
Tubing |
|||
3/4" – 2" Raupex | 3/4" - 2" Raupex White UV- Shield | ||
% PEX pipe and fittings are intended for use in multi-purpose piping systems of residential occupancies as defined in ANSI/NFPA 13D, “Installation of Sprinkler Systems in One- and Two- Family Dwellings and Manufactured Homes" and the International Residential Code, Section P2904, and are designed to withstand a working pressure of not less than 130 psi at 120°F. PEX pipe and fittings are intended to be installed in accordance with the requirements specified in the manufacturer’s installation instructions and ANSI/NFPA 13D. Protection is intended to be provided for PEX pipe and fittings in multi-purpose piping systems unless otherwise stated in this listing and per the installation and design manual dated September 11, 2008. The minimum protection should consist of either (1) one layer of 3/8-in. gypsum wallboard, (2) a suspended membrane ceiling with lay-in panels or tiles having a weight of not less than 0.35 lbs per sq ft when installed with metallic support grids, OR (3) ½ in plywood. PEX pipe and fittings are intended for use in areas where the maximum ambient temperature does not exceed 120°F. These pipe and fittings are not intended to be installed in outdoor applications. The PEX pipe and fittings are intended for use in wet-pipe systems only and have not been evaluated for use in dry-pipe systems. Raupex pipe and fittings may also be installed without protection (exposed) in accordance with the limitations specified in this installation and design manual dated September 11, 2008. ** Pipe and fittings Certified as a system using installation and design manual titled "FIREPEX Residential Fire Sprinkler Systems". [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : EU
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing[1] [2] |
PEX |
NEOPEX O2 Barrier |
ASTM E84 |
1/2", 5/8", 3/4" | |||
[1] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. [2] 1/2", 5/8" 3/4" Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with 1/2" Micro-lok HP Hi performance fiberglass insulation as per Rehau installation instructions. 1/2" Only: Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50]. |
|||
Tubing[1] [3] |
PEX |
NEOPEX O2 Barrier |
CAN/ULC S102.2 |
1/2", 5/8", 3/4" | |||
[1] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. [3] 1/2" - Non-insulated 5/8" & 3/4": Flame Spread Index and Smoke Developed Index based on when tubing is field instructions. insulated with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation. Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50]. |
Rifeng Enterprise (Foshan) Co., Ltd. | |
5th/F, Rifeng Building | |
16 Zumiao Road | |
Foshan, Guangdong 528000 | |
China | |
86 757 8230 1768 |
Facility : Foshan, China
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing# $ * [2] [10] |
PEX |
Rifeng |
ASTM E84 |
3/8", 1/2" - 2" | |||
# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation instructions. The 3/8" tubing is not insulated. $ Certified for blue, natural, red, and white without oxygen barrier. * Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [10] ASTM E84, 1/2" - 2" The Flame Spread Index and Smoke Developed Index for 1/2" - 2" tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation instructions. The 3/8" tubing is not insulated. |
|||
Tubing$ & [2] [11] |
PEX |
Rifeng |
CAN/ULC S102.2 |
3/8", 1/2" - 2" | |||
$ Certified for blue, natural, red, and white without oxygen barrier. & 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50]. 1/2" - 2" tubing (with insulation), Flame Spread Index and Smoke Developed Index based on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. [2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [11] 3/8" Tubing (without insulation) Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. 1/2" through 2" Tubing (with insulation) Flame Spread Rating and Smoke Developed Classification based on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. |
|||
Tubing[1] [3] |
PEX |
RIFENG PEX |
ASTM E84 |
3/8" - 2"[2] | |||
[2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [1] Certified for red and white PEX 5106 monowall pipe. [3] The Flame Spread Index and Smoke Developed Index are based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation instructions. Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
|||
Tubing[1] [4] |
PEX |
RIFENG PEX |
CAN/ULC S102.2 |
3/8" - 2"[2] | |||
[2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [1] Certified for red and white PEX 5106 monowall pipe. [4] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. |
|||
Tubing[5] [6] |
PEX |
RIFENG PEX |
ASTM E84 |
3/8" - 1"[2] | |||
[2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [5] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier pipe. [6] The Flame Spread Index and Smoke Developed Index are based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation instructions (all listed construction/color/size combinations greater than or equal to 3/8" in diameter). Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
|||
Tubing[5] [7] |
PEX |
RIFENG PEX |
CAN/ULC S102.2 |
3/8" - 1"[2] | |||
[2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [5] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier pipe. [7] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's installation instructions (all listed construction/color/size combinations greater than or equal to 3/8" in diameter). Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. |
|||
Tubing[3] [8] |
PEX |
RIFENG PEXa |
ASTM E84 |
1/8" - 3"[2] | |||
[2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [3] The Flame Spread Index and Smoke Developed Index are based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation instructions. Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [8] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only. |
|||
Tubing[4] [8] |
PEX |
RIFENG PEXa |
CAN/ULC S102.2 |
1/8" - 3"[2] | |||
[2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [4] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. [8] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for red, white, blue 2-layer tubing for 1/2", 5/8" 3/4", 1" sizes only. |
|||
Tubing[3] [9] |
PEX |
RIFENG PEXa |
ASTM E84 |
1/8" - 3"[2] | |||
[2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [3] The Flame Spread Index and Smoke Developed Index are based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation instructions. Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [9] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red, white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. |
|||
Tubing[4] [9] |
PEX |
RIFENG PEXa |
CAN/ULC S102.2 |
1/8" - 3"[2] | |||
[2] Flame Spread Index <= 25 Smoke Developed Index <= 50 [4] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field insulated with 1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. [9] Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red, white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. |
Riifo North America | |
4737 Smokey Bear Lane | |
Columbia Falls, MT 59912 | |
United States | |
406-250-4412 |
Facility : # 1 China
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing# $ * |
PEX |
Riifo |
ASTM E84 |
3/8", 1/2" - 2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation instructions. The 3/8" tubing is not insulated. $ Certified for blue, natural, red, and white without oxygen barrier. * Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
|||
Tubing$ & |
PEX |
Riifo |
CAN/ULC S102.2 |
3/8", 1/2" - 2" |
|||
Flame Spread Rating <= 25 | Smoke Developed Classification <= 50 | ||
$ Certified for blue, natural, red, and white without oxygen barrier. & 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50]. 1/2" - 2" tubing (with insulation), Flame Spread Index and Smoke Developed Index based on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. |
S & B Technical Products, Inc. / Terramix S.A. | |
1300 East Berry Street | |
Ft. Worth, TX 76119 | |
United States | |
800-432-8213 | |
817-923-3344 |
Facility : Santa Ana, Costa Rica (Hultec)
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Gaskets+ [1] |
EPDM |
EPDM HT553 Rieberlok Gasket |
UL 1285 |
4" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 C900 1 Piece RR |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 C900 CIOD DD |
UL 1285 |
4" - 18" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 C900 Platinum Pressure |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 C900 Rieber |
UL 1285 |
2" - 16" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 C900 Super Rieber Patented |
UL 1285 |
2" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 C905 1 Piece RR |
UL 1285 |
14" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 C905 Platinum Pressure |
UL 1285 |
14" - 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 C905 Super Rieber Patented |
UL 1285 |
14" - 48" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 C909 Biax Mambo |
UL 1285 |
4" - 16" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 Fast Grip |
UL 1285 |
4" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 Fastite Gasket |
UL 1285 |
4" - 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 Field LOK |
UL 1285 |
4" - 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 FIELD LOK 350® |
UL 1285 |
4" - 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 Flange Tyte |
UL 1285 |
4" - 64" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 Full Face Flange Tyte |
UL 1285 |
4" - 64" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 IPS 2241 Rieber |
UL 1285 |
1 1/2" - 18" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 IPS 2241 Super Rieber |
UL 1285 |
14" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 IPS Biax Mambo |
UL 1285 |
3" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 IPS Hero |
UL 1285 |
1 1/2" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 LOKX System DIPS |
UL 1285 |
4"-12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 LOKX System IPS |
UL 1285 |
4"-12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 Metric Pressure |
UL 1285 |
50 mm - 630 mm | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 Metric Tyton |
UL 1285 |
80 mm - 1200 mm | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 MJ Field Lok |
UL 1285 |
4" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 One Piece Retainer Ring CIOD |
UL 1285 |
4" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 PIP DD |
UL 1285 |
10" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 PR IPS |
UL 1285 |
6" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 Rest MJ (PVC) |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 Rieber IPS |
UL 1285 |
1 1/2" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 S-Ring |
UL 1285 |
6" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 Sure Stop |
UL 1285 |
4" - 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 T Saddle IP |
UL 1285 |
4" - 6" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 TURNER BIAX C909 |
UL 1285 |
4" - 16" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 TURNER BIAX IPS |
UL 1285 |
4" - 16" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 TURNER C909 |
UL 1285 |
4" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 Turner Lock |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 Tyton CM |
UL 1285 |
3" - 42" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 TYTON GASKET |
UL 1285 |
3" - 64" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 USIFLEX |
UL 1285 |
30" - 54" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
EPDM |
EPDM HT553 Y Saddle IP |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 C900 1 Piece RR |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 C900 CIOD DD |
UL 1285 |
4" - 18" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 C900 Platinum Pressure |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 C900 Rieber |
UL 1285 |
2" - 16" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 C900 Super Rieber Patented |
UL 1285 |
2" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 C905 1 Piece RR |
UL 1285 |
14" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 C905 B/C Ring Certalok |
UL 1285 |
>= 4" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 C905 Platinum Pressure |
UL 1285 |
14" - 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 C905 Super Rieber Patented |
UL 1285 |
14" - 48" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 C909 Biax Mambo |
UL 1285 |
4" - 16" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 Fast Grip |
UL 1285 |
4" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 Fastite Gasket |
UL 1285 |
4" - 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 Field LOK |
UL 1285 |
4" - 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 FIELD LOK 350® |
UL 1285 |
4" - 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 Flange Tyte |
UL 1285 |
4" - 64" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 Fluid Tite |
UL 1285 |
>= 4" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 Full Face Flange Tyte |
UL 1285 |
4" - 64" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 IPS 2241 Rieber |
UL 1285 |
1 1/2" - 18" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 IPS 2241 Super Rieber |
UL 1285 |
14" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 IPS Biax Mambo |
UL 1285 |
3" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 IPS Hero |
UL 1285 |
1 1/2" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 Metric Pressure |
UL 1285 |
50 mm - 630 mm | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 Metric Tyton |
UL 1285 |
80 mm - 1200 mm | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 MJ Field Lok |
UL 1285 |
4" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 One Piece Retainer Ring CIOD |
UL 1285 |
4" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 PIP DD |
UL 1285 |
10" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 PR IPS |
UL 1285 |
6" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 Rest MJ (PVC) |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 Rieber IPS |
UL 1285 |
1 1/2" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 S-Ring |
UL 1285 |
6" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 Sure Stop |
UL 1285 |
4" - 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 TURNER BIAX C909 |
UL 1285 |
4" - 16" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 TURNER BIAX IPS |
UL 1285 |
4" - 16" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 TURNER C909 |
UL 1285 |
4" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 Tyton |
UL 1285 |
4" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 Tyton CM |
UL 1285 |
3"- 42" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT4537 Yellowmine |
UL 1285 |
>= 4" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT553 LOKX System DIPS |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
NBR |
NBR HT553 LOKX System IPS |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Rieberlok Gasket |
UL 1285 |
4" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 RCT Flex Tite C900 |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 RCT Flex Tite IPS Transition |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 A/T IPS Gasket |
UL 1285 |
1.5" - 4" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 C900 CIOD DD SBR Gasket |
UL 1285 |
4" - 18" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 C900 Rieber Gasket |
UL 1285 |
2" - 16" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 C900 Super Rieber Patented Gasket |
UL 1285 |
2" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 C905 Super Rieber Patented Gasket |
UL 1285 |
14" - 48" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 C909 Biax Mambo Gasket |
UL 1285 |
4" - 16" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 CIOD Hero |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 CIOD RIEBER HR |
UL 1285 |
14" | 16" | 18" | 20" |
30" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Fast Grip |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Fastite Gasket |
UL 1285 |
4" - 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 FIELD LOK 350® |
UL 1285 |
4" - 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Field LOK SBR Gasket |
UL 1285 |
4" - 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 LOKX System DIPS |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 LOKX System IPS |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Flange Tyte Gasket |
UL 1285 |
4" - 64" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Flo Control IPS Gasket |
UL 1285 |
2.5" - 8" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Full Face Flange Tyte |
UL 1285 |
4" - 64" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 IPS 2241 Rieber Gasket |
UL 1285 |
1.5" - 18" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 IPS 2241 Super Rieber Gasket |
UL 1285 |
14" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 IPS Biax Mambo Gasket |
UL 1285 |
3" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 IPS Hero |
UL 1285 |
1.5" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Lock Push On Gasket |
UL 1285 |
4" - 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 MJ Field Lok Gasket |
UL 1285 |
4" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 One-Piece Retainer Ring CIOD Gasket |
UL 1285 |
4" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 PIP DD SBR Gasket |
UL 1285 |
10" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Plastic Retainer Ring IPS Gasket |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Platinum Press SBR Ozone | Gasket |
UL 1285 |
63mm - 225mm | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Push-On Gasket |
UL 1285 |
3" - 42" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Push-On Metric Gasket |
UL 1285 |
80mm - 1200mm | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 RCT |
UL 1285 |
4" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Rest MJ (PVC) |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Rieber CIOD Gasket |
UL 1285 |
4" - 48" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Rieber IPS Gasket |
UL 1285 |
1.5" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Rieber Metric Pressure Gasket |
UL 1285 |
50mm - 630mm | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Rieber Metric Pressure Platinum Gkt |
UL 1285 |
50mm - 1200mm | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 S-Ring |
UL 1285 |
6" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Self Lock Push-On Gasket |
UL 1285 |
3" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Sewer Ret/ Ring |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Super Bell Tite Gasket |
UL 1285 |
4" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Sure Stop Gasket |
UL 1285 |
4" - 36" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 THAI Gasket |
UL 1285 |
100mm - 400mm | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Turner C909 |
UL 1285 |
4" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Turner Lock |
UL 1285 |
4" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Tyton Gasket |
UL 1285 |
3" - 64" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 VF Sewer |
UL 1285 |
4" - 8" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Turner Biax C909 |
UL 1285 |
4" - 16" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
|||
Gaskets+ [1] |
SBR |
SBR HT627 Turner Biax IPS |
UL 1285 |
4" - 16" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] Product is Certified as meeting the elastomeric gasket requirements of UL 1285. |
Safelink Systems, Inc. DBA MrPEX Systems | |
14799 Jackal Street NW | |
Suite 100 | |
Ramsey, MN 55303 | |
United States | |
800-716-3406 | |
952-652-2472 | |
Visit this company's website |
Facility : # 1
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing^ § ** |
PEX |
Mr Pex® Potable |
ASTM E84 |
1/2", 3/4" | |||
^ Flame Spread Index <= 25, Smoke Developed Index <= 50 § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. ** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
Sanderson Pipe Corporation | |
875 International Boulevard | |
Clarksville, TN 37040 | |
United States | |
904-275-2833 |
Facility : # 2 USA
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe |
PVC |
S.P.C.N. |
UL 1285 |
PC 165: 4", 6", 8", 10", 12", 14", 16", 18", 20", 24" DR 25 | |||
PC 200: 14", 16", 18", 20", 24" DR 21 | |||
PC 235: 4", 6", 8", 10", 12", 14", 16", 18", 20", 24" DR 18 | |||
PC 305: 4", 6", 8", 10", 12", 14", 16", 18", 20", 24" DR 14 |
Facility : Pittsburg, KS
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Pipe |
PVC |
S.P.C.K |
UL 1285 |
PC 165: 4", 6", 8", 10", 12" DR 25 | |||
PC 235: 4", 6", 8", 10", 12" DR 18 | |||
PC 305: 4", 6", 8", 10", 12" DR 14 |
Silver-Line Plastics LLC | |
900 Riverside Drive | |
Asheville, NC 28804 | |
United States | |
828-252-8755 | |
Visit this company's website |
Facility : Ft. Pierce, FL
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Pipe~ [1] [2] |
PVC |
Silver-Line |
CAN/ULC S102.2 |
1/2" - 12" Sch 40 | |||
1/2" - 8" Sch 80 | |||
~ Product is authorized to bear the cNSF Mark. [1] Approved for a thickness of 3 mm - 14mm. [2] Flame Spread Value (FSV) =10 Smoke Developed Value (SDV) =195 |
|||
Pipe~ [1] [2] |
PVC |
Xirtec PVC |
CAN/ULC S102.2 |
1/2" - 12" Sch 40 | |||
1/2" - 8" Sch 80 | |||
~ Product is authorized to bear the cNSF Mark. [1] Approved for a thickness of 3 mm - 14mm. [2] Flame Spread Value (FSV) =10 Smoke Developed Value (SDV) =195 |
Facility : Asheville, NC
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Pipe~ [1] [2] |
PVC |
Silver-Line |
CAN/ULC S102.2 |
1/2" - 12" Sch 40 | |||
1/2" - 8" Sch 80 | |||
~ Product is authorized to bear the cNSF Mark. [1] Approved for a thickness of 3 mm - 14mm. [2] Flame Spread Value (FSV) =10 Smoke Developed Value (SDV) =195 |
|||
Pipe~ [1] [2] |
PVC |
Xirtec PVC |
CAN/ULC S102.2 |
1/2" - 12" Sch 40 | |||
1/2" - 8" Sch 80 | |||
~ Product is authorized to bear the cNSF Mark. [1] Approved for a thickness of 3 mm - 14mm. [2] Flame Spread Value (FSV) =10 Smoke Developed Value (SDV) =195 |
|||
Pipe~ [1] [2] |
PVC |
RadonX |
CAN/ULC S102.2 |
4" Sch 40 | |||
~ Product is authorized to bear the cNSF Mark. [1] Approved for a thickness of 3 mm - 14mm. [2] Flame Spread Value (FSV) =10 Smoke Developed Value (SDV) =195 |
Facility : Lawton, OK
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Pipe~ [1] [2] |
PVC |
Silver-Line |
CAN/ULC S102.2 |
1/2" - 12" Sch 40 | |||
1/2" - 8" Sch 80 | |||
~ Product is authorized to bear the cNSF Mark. [1] Approved for a thickness of 3 mm - 14mm. [2] Flame Spread Value (FSV) =10 Smoke Developed Value (SDV) =195 |
|||
Pipe~ [1] [2] |
PVC |
Xirtec PVC |
CAN/ULC S102.2 |
1/2" - 12" Sch 40 | |||
1/2" - 8" Sch 80 | |||
~ Product is authorized to bear the cNSF Mark. [1] Approved for a thickness of 3 mm - 14mm. [2] Flame Spread Value (FSV) =10 Smoke Developed Value (SDV) =195 |
The Boys, LLC dba SupplyHouse.com | |
130 Spagnoli Road | |
Melville, NY 11747 | |
United States | |
631-393-2855 |
Facility : # 1 China
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing# $ * |
PEX |
Bluefin |
ASTM E84 |
3/8", 1/2" - 2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass $ Certified for blue, natural, red, and white without oxygen barrier. * Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
|||
Tubing$ & |
PEX |
Bluefin |
CAN/ULC S102.2 |
3/8", 1/2" - 2" |
|||
Flame Spread Rating <= 25 | Smoke Developed Classification <= 50 | ||
$ Certified for blue, natural, red, and white without oxygen barrier. & 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50]. 1/2" - 2" tubing (with insulation), Flame Spread Index and Smoke Developed Index based on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. |
The Mosack Group, Inc. | |
701 Matthews-Mint Hill Road | |
Matthews, NC 28105 | |
United States | |
704-847-9191 |
Facility : Foshan, China
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing# $ * ^ § +++ [G] |
PEX |
Apollo/TMG/PurePEX/PureLink |
ASTM E84 |
3/8", 1/2" - 2"[1] |
|||
WPPB2012 | WPPW2012 | WPPW2034 | WPPR2034 |
WPPB2034 | WPPR2012 | WPPW201 | |
68PXB100012 1/2" |
|||
Flame Spread Index <= 25 | Flame Spread Index <= 25 | ||
68PXB100038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB1001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB10012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB10034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB10038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB1012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB1034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB201 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB2012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB2034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB3001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB30012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB30034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB5001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB50012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB50034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB50038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR100012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR100038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR1001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR10012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR10034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR10038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR1012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR1034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR201 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR2012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR2034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR3001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR30012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR30034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR5001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR50012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR50034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR50038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW100012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW100038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW1001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW10012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW10034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW10038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW1012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW1034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW201 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW2012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW2034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW3001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW30012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW30034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW5001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW50012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW50034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW50038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB1001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB10012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB10034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB101 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB1210 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB201 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB2012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB2034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB212 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB234 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB30012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB30034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB3410 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB50012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB50034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB512 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB534 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR1001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR10012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR10034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR101 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR1210 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR201 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR2012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR2034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR212 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR234 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR30012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR30034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR3410 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR50012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR50034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR512 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR534 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW1001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW10012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW10034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW101 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW1012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW1034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW1038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW201 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW2012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW2034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW212 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW234 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW2512 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW2534 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW30012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW30034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW50012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW50034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW5012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW5034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW51 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW512 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW534 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW538 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
[1] Flame Spread Index <= 25 Smoke Developed Index <= 50 # The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation instructions. The 3/8" tubing is not insulated. $ Certified for blue, natural, red, and white without oxygen barrier. * Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. ^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with ASTM F2023. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||
Tubing$ & § +++ [G] |
PEX |
Apollo/TMG/PurePEX/PureLink |
CAN/ULC S102.2 |
3/8", 1/2" - 2"[1] |
|||
WPPB2012 | WPPR2012 | WPPR2034 | WPPW2034 |
WPPW201 | WPPB2034 | WPPW2012 | |
68PXB100012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB100038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB1001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB10012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB10034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB10038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB1012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB1034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB201 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB2012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB2034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB3001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB30012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB30034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB5001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB50012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB50034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXB50038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR100012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR100038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR1001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR10012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR10034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR10038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR1012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR1034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR201 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR2012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR2034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR3001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR30012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR30034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR5001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR50012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR50034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXR50038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW100012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW100038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW1001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW10012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW10034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW10038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW1012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW1034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW201 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW2012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW2034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW3001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW30012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW30034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW5001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW50012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW50034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
68PXW50038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB1001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB10012 1/2" |
|||
Flame Spread Rating <= 25 | Smoke Developed Classification <= 50 | ||
APPB10034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB101 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB1210 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB201 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB2012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB2034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB212 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB234 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB30012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB30034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB3410 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB50012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB50034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB512 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPB534 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR1001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR10012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR10034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR101 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR1210 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR201 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR2012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR2034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR212 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR234 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR30012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR30034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR3410 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR50012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR50034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR512 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPR534 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW1001 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW10012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW10034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW101 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW1012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW1034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW1038 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW201 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW2012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW2034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW212 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW234 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW2512 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW2534 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW30012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW30034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW50012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW50034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW5012 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW5034 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW51 1" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW512 1/2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW534 3/4" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
APPW538 3/8" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
[1] Flame Spread Index <= 25 Smoke Developed Index <= 50 $ Certified for blue, natural, red, and white without oxygen barrier. & 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50]. 1/2" - 2" tubing (with insulation), Flame Spread Index and Smoke Developed Index based on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
The Mosack Group, Inc. | |
11210 Allen Station Drive | |
Mint Hill, NC 28227 | |
United States | |
888-229-2874 |
Facility : Mint Hill, NC
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing^ § ** |
PEX |
Apollo |
ASTM E84 |
1/2", 3/4" | |||
^ Flame Spread Index <= 25, Smoke Developed Index <=50 § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. ** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
Facility : Calgary, Alberta, Canada
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing^ § ** |
PEX |
Apollo |
ASTM E84 |
1/2", 3/4" | |||
^ Flame Spread Index <= 25, Smoke Developed Index <=50 § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. ** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
Trelleborg Pipe Seals Tijuana S.A de C.V | |
Colina No. 11850, Parque | |
Industrial el Florido, Sección Colinas | |
Tijuana, BC 22237 | |
Mexico | |
52 664 625 4885 |
Facility : Tijuana, Baja California, Mexico
Fire Main - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard |
Gasket/Sealing Materials+ ~ |
SBR |
T-565 RIEBER C-900 SBR |
FM 1612 |
4" - 48" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
SBR |
T-559 RIEBER PRESSURE METRIC SBR |
FM 1612 |
450 mm - 1200 mm | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
SBR |
T-560 RIEBER IPS SBR |
FM 1612 |
1-1/2" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
SBR |
MP 148 T-559 RIEBER PRESSURE METRIC SBR |
FM 1612 |
450" - 1200" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
SBR |
MP 148 T-560 RIEBER IPS SBR |
FM 1612 |
1-1/2" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
SBR |
MP 148 T-565 RIEBER C-900 SBR |
FM 1612 |
4" - 48" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
SBR |
CERTA-LOK O-RING SBR |
FM 1612 |
5" - 48" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
NBR |
T-560 RIEBER IPS NITRILE |
FM 1612 |
1 1/2 - 24 in | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
NBR |
T-565 RIEBER C-900 NITRILE |
FM 1612 |
4" - 48" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
NBR |
NR 648 T-560 RIEBER IPS NITRILE |
FM 1612 |
1-1/2" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
NBR |
NR 648 T-565 RIEBER C-900 NITRILE |
FM 1612 |
4" - 48" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
NBR |
CERTA-LOK O-RING NITRILE |
FM 1612 |
2" - 10" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
NBR |
FLUID-TITE NITRILE CIOD |
FM 1612 |
6" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
EPDM |
T-560 RIEBER IPS EPDM |
FM 1612 |
1-1/2" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
EPDM |
T-565 RIEBER C-900 EPDM |
FM 1612 |
4" - 48" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
EPDM |
T-584 ANGER LOCK EPDM |
FM 1612 |
4" - 48" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
EPDM |
T-552 ANGER LOCK IPS EPDM |
FM 1612 |
2"-14" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
EPDM |
T-603 POWER LOCK IPS EPDM |
FM 1612 |
1-1/2" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
EPDM |
E 148 T-560 RIEBER IPS EPDM |
FM 1612 |
1-1/2" - 24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
EPDM |
E 148 T-565 RIEBER C-900 EPDM |
FM 1612 |
4" - 48" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
EPDM |
E 148 T-552 ANGER LOCK IPS EPDM |
FM 1612 |
2"-14" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
EPDM |
E 148 T-584 ANGER LOCK EPDM |
FM 1612 |
4" - 48" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
EPDM |
E 148 T-603 POWER LOCK IPS EPDM |
FM 1612 |
1-1/2" - 12" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
EPDM |
CERTA-LOK O-RING EPDM |
FM 1612 |
2"-10" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
|||
Gasket/Sealing Materials+ ~ |
EPDM |
FLUID-TITE EPDM CIOD |
FM 1612 |
6"-24" | |||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
Uponor | |
5925 148th Street West | |
Apple Valley, MN 55124 | |
United States | |
800-321-4739 | |
952-891-2000 | |
Visit this company's website |
Facility : Apple Valley, MN
Fire Sprinkler Pipe and Fitting Systems
Product Type | Material Type | Trade Name | Product Standard |
Pipe and Fitting System% ¢ ** |
MLTPL |
AQUASAFE®* |
ANSI/CAN/UL 1821 |
Coupling |
|||
LF4545075 - ProPEX LF Brass Coupling, 1/2" PEX x 3/4" PEX | LF4547510 - ProPEX LF Brass Coupling, 3/4" PEX x 1" PEX | LF4547575 - ProPEX LF Brass Coupling, 3/4" PEX x 3/4" PEX | LF4541010 - ProPEX LF Brass Coupling, 1" PEX x 1" PEX |
Q4777510/Q4777510R5 - ProPEX EP Coupling, 3/4" PEX x 1" PEX | Q4777575/Q47775R5/Q47775R20 - ProPEX EP Coupling, 3/4" PEX x 3/4" PEX | Q4771010/Q47710R5 - ProPEX EP Coupling, 1" PEX x 1" PEX | Q4771307 - ProPEX EP Coupling, 1 1/4" PEX x 3/4" PEX |
Q4771310 - ProPEX EP Coupling, 1 1/4" PEX x 1" PEX | Q4771313 - ProPEX EP Coupling, 1 1/4" PEX x 1 1/4" PEX | ||
Elbow |
|||
LF4710500 - ProPEX LF Brass Elbow, 1/2" PEX x 1/2" PEX | LF4710750 - ProPEX LF Brass Elbow, 3/4" PEX x 3/4" PEX | LF4711000 - ProPEX LF Brass Elbow, 1" PEX x 1" PEX | Q4760500/Q4760500R5/Q4760500R25 - ProPEX EP Elbow, 1/2" PEX x 1/2" PEX |
Q4760750/Q4760750R5/Q4760750R10 - ProPEX EP Elbow, 3/4" PEX x 3/4" PEX | Q4761000/Q4761000R5 - ProPEX EP Elbow, 1" PEX x 1" PEX | Q4761250 - ProPEX EP Elbow, 1 1/4" PEX x 1 1/4" PEX | Q4761515 - ProPEX 45 degree EP Elbow, 1-1/2" x 1-1/2" |
Q4762020 - ProPEX 45 degree EP Elbow, 2" x 2" | |||
Female Adapter |
|||
LF4577575 - ProPEX LF Brass Female Threaded Adapter, 3/4" PEX x 3/4" NPT | LF4571010/LF45710R - ProPEX LF Brass Female Threaded Adapter, 1" PEX x 1" NPT | LF4571313 - ProPEX LF Brass Female Threaded Adapter, 1 1/4" PEX x 1 1/4" NPT | LF4571515 - ProPEX LF Brass Female Threaded Adapter, 1 1/2" PEX x 1 1/2" NPT |
LF4572020 - ProPEX LF Brass Female Threaded Adapter, 2" PEX x 2" NPT | |||
Fire Sprinkler Head Adapter |
|||
LF7707575 - ProPEX LF Brass Fire Sprinkler Adapter Tee,¾" PEX x ¾" PEX x ½" FNPT | LF7701010 - ProPEX LF Brass Fire Sprinkler Adapter Tee,1" PEX x 1" PEX x ½: FNPT | LF7717550 - ProPEX LF Brass Fire Sprinkler Adapter Elbow, 3/4" PEX x 1/2" FNPT | LF7711050 - ProPEX LF Brass Fire Sprinkler Adapter Elbow, 1" PEX x 1/2" FNPT |
Male Adapter |
|||
LF4527575/LF45275R - ProPEX LF Brass Male Threaded Adapter, 3/4" PEX x 3/4" NPT | LF4521010/LF45210R - ProPEX LF Brass Male Threaded Adapter, 1" PEX x 1" NPT | LF4521313 - ProPEX LF Brass Male Threaded Adapter, 1 1/4" PEX x 1 1/4" NPT | |
Opposing Port Tees |
|||
Q4801075 - ProPEX EP Opposing Port Tee, 1" PEXx1" PEXx3/4"PEXx3/4" PEX | Q4801375 - ProPEX EP Opposing Port Tee, 1 1/4" PEXx1 1/4" PEXx3/4" PEXx3/4" PEX | Q4801575 - ProPEX EP Opposing Port Tee-1 1/2" PEXx1 1/2" PEXx3/4" PEXx3/4" PEX | Q4802075 - ProPEX EP Opposing Port Tee-2" PEXx2" PEXx3/4"PEXx3/4" PEX |
Plug |
|||
Q4350750/Q4350750R5 - ProPEX EP Plug, 3/4" PEX | Q4351000/Q4351000R5 - ProPEX EP Plug , 1" PEX | Q4351250 - ProPEX EP Plug, 1 1/4" | |
ProPEX Rings |
|||
Q4690756/Q4690756R10/Q4690756R30 - 3/4" ProPEX Ring with Stop | Q4691000/Q4691000R10 - 1" ProPEX Ring with Stop | Q4691250 - 1 1/4" ProPEX Ring with Stop | |
Reducing Tee |
|||
LF4707550 - ProPEX LF Brass Tee, 3/4" PEX x 3/4" PEX x 1/2" PEX | LF4707710 - ProPEX LF Brass Tee, 3/4" PEX x 3/4" PEX x 1" PEX | LF4701150 - ProPEX LF Brass Tee, 1" PEX x 1" PEX x 1/2" PEX | LF4701175 - ProPEX LF Brass Tee, 1" PEX x 1" PEX x 3/4" PEX |
LF4701751 - ProPEX LF Brass Tee, 1" PEX x 3/4" PEX x 1" PEX | LF4701775 - ProPEX LF Brass Tee, 1" PEX x 3/4" PEX x 3/4" PEX | Q4757550/Q4757550R5 - ProPEX EP Reducing Tee, 3/4" PEX x 3/4" PEX x 1/2" PEX | Q4757557 - ProPEX EP Reducing Tee, 3/4" PEX x 1/2" PEX x 3/4" PEX |
Q4757557R8 - ProPEX EP Reducing Tee, 3/4" PEX x 1/2" PEX x 3/4" PEX - copy | Q4757557 - ProPEX EP Reducing Tee, 3/4" PEX x 1/2" PEX x 3/4" PEX - copy | Q4757710 - ProPEX EP Reducing Tee, 3/4" PEX x 3/4" PEX x 1" PEX | Q4751113 - ProPEX EP Reducing Tee, 1" PEX x 1" PEX x 1 1/4" |
Q4751150 - ProPEX EP Reducing Tee, 1" PEX x 1" PEX x 1/2" PEX | Q4751175/Q4751175R5 - ProPEX EP Reducing Tee, 1" PEX x 1" PEX x 3/4" PEX | Q4751311 - ProPEX EP Reducing Tee, 1 1/4" PEX x 1" PEX x 3/4" PEX | Q4751317 - ProPEX EP Reducing Tee, 1 1/4" PEX x 1" PEX x 1" PEX |
Q4751331 - ProPEX EP Reducing Tee, 1 1/4" PEX x 1 1/4" PEX x 1" PEX | Q4751337 - ProPEX EP Reducing Tee, 1 1/4" PEX x 1 1/4" PEX x 3/4" PEX | Q4751371 - ProPEX EP Reducing Tee, 1 1/4" PEX x 3/4" PEX x 1" PEX | Q4751373 - ProPEX EP Reducing Tee, 1 1/4" PEX x 3/4" PEX x 1 1/4" PEX |
Q4751377 - ProPEX EP Reducing Tee, 1 1/4" PEX x 3/4" PEX x 3/4" PEX | Q4751511 - ProPEX EP Reducing Tee, 1 1/2" PEX x 1" PEX x 1" PEX | Q4751517 - ProPEX EP Reducing Tee, 1 1/2" PEX x 1" PEX x 3/4" PEX | Q4751551 - ProPEX EP Reducing Tee, 1 1/2" PEX x 1 1/2" PEX x 3/4" PEX |
Q4751553 - ProPEX EP Reducing Tee, 1 1/2" PEX x 1 1/2" PEX x 1 1/4" PEX | Q4751557 - ProPEX EP Reducing Tee, 1 1/2" PEX x 1 1/2" PEX x 1" PEX | Q4751751/Q4751751R5 - ProPEX EP Reducing Tee, 1" PEX x 3/4" PEX x 1" PEX | Q4751775 - ProPEX EP Reducing Tee, 1" PEX x 3/4" PEX x 3/4" PEX |
Q47515501 - ProPEX EP Reducing Tee, 1/2" x 1-1/2" x 1/2" | Q4751350 - ProPEX EP Reducing Tee, 1-1/4" x 1-1/4" x 1/2" | Q4751505 - ProPEX EP Reducing Tee, 1-1/2" x 1" x 1-1/2" | Q4752152 - ProPEX EP Reducing Tee, 2" x 1-1/2" x 2" |
Q4752250 - ProPEX EP Reducing Tee, 2" x 2" x 1/2" | |||
Sweat Adapter |
|||
LF4517575/LF45175R - ProPEX LF Brass Sweat Adapter, 3/4" PEX x 3/4" Copper | LF4511010/LF45110R - ProPEX LF Brass Sweat Adapter 1" PEX x 1" Copper | LF4511313 - ProPEX LF Brass Sweat Adapter, 1 1/4" PEX x 1 1/4" Copper | LF4511515 - ProPEX LF Brass Sweat Adapter, 1 1/2" PEX x 1 1/2" Copper |
LF4512020 - ProPEX LF Brass Sweat Adapter, 2" PEX x 2" Copper | |||
Tee |
|||
LF4707575 - ProPEX LF Brass Tee, 3/4" PEX x 3/4" PEX x 3/4" PEX | LF4701010 - ProPEX LF Brass Tee, 1" PEX x 1" PEX x 1" PEX | Q4757575/Q4757575R5 - ProPEX EP Tee, 3/4" PEX x 3/4" PEX x 3/4" PEX | Q4751010 - ProPEX EP Tee, 1" PEX x 1" PEX x 1" PEX |
Q4751313 - ProPEX EP Tee, 1 1/4" PEX x 1 1/4" PEX x 1 1/4" PEX | WS4360751/SWP4360751 - ProPEX EP Elbow Water Meter Connector, 3/4" PEX x 1" NPSM | WS4361001 - ProPEX EP Elbow Water Meter Connector, 1" PEX x 1 1/4" NPSM | WS4360750/SWP4360750- ProPEX EP Straight Water Meter Connector, 3/4" PEXx1" NPSM |
WS4360750R - ProPEX EP Straight Water Meter Connector, 3/4" PEXx1" NPSM | WS4361000 - ProPEX EP Straight Water Meter Connector, 1" PEX x 1 1/4" NPSM | ||
Tubing |
|||
3/4" Uponor AquaPEX White | 1" Uponor AquaPEX White | 1 1/4" Uponor AquaPEX White | |
% PEX pipe and fittings are intended for use in multi-purpose piping systems of residential occupancies as defined in ANSI/NFPA 13D, "Installation of Sprinkler Systems in One- and Two- Family Dwellings and Manufactured Homes", the National Building Code of Canada, and the International Residential Code, Section 2904, and are designed to withstand a working pressure of not less than 130 psi at 120° F. PEX pipe and fittings are intended to be installed in accordance with the requirements specified in the manufacturer’s installation instructions and ANSI/NFPA 13D. Protection is intended to be provided for PEX pipe and fittings in multi-purpose piping systems. The minimum protection should consist of either (1) one layer of 3/8-in. gypsum wallboard, (2) a suspended membrane ceiling with lay-in panels or tiles having a weight of not less than 0.35 lbs per sq ft when installed with metallic support grids, (3) 1/2 in plywood or (4) other material with a 15 minute fire rating. PEX pipe and fittings are intended for use in areas where the maximum ambient temperature does not exceed 120° F. These pipe and fittings are not intended to be installed in outdoor applications. The PEX pipe and fittings are intendedfor use in wet-pipe systems only and have not been evaluated for use in dry-pipe systems. * These products may also be represented by the trade name AquaPEX. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. ** Pipe and fittings Certified as a system using installation and design manual titled "Uponor Residential Fire Sprinkler Systems, AquaSAFE™ System Installation Guide". |
Facility : Hutchinson, MN
Fire Sprinkler Pipe and Fitting Systems
Product Type | Material Type | Trade Name | Product Standard |
Pipe and Fitting System% ¢ ** |
PEX |
AQUASAFE®* |
ANSI/CAN/UL 1821 |
Tubing |
|||
3/4" Uponor AquaPEX White | 1" Uponor AquaPEX White | ||
% PEX pipe and fittings are intended for use in multi-purpose piping systems of residential occupancies as defined in ANSI/NFPA 13D, "Installation of Sprinkler Systems in One- and Two- Family Dwellings and Manufactured Homes", the National Building Code of Canada, and the International Residential Code, Section 2904, and are designed to withstand a working pressure of not less than 130 psi at 120° F. PEX pipe and fittings are intended to be installed in accordance with the requirements specified in the manufacturer’s installation instructions and ANSI/NFPA 13D. Protection is intended to be provided for PEX pipe and fittings in multi-purpose piping systems. The minimum protection should consist of either (1) one layer of 3/8-in. gypsum wallboard, (2) a suspended membrane ceiling with lay-in panels or tiles having a weight of not less than 0.35 lbs per sq ft when installed with metallic support grids, (3) 1/2 in plywood or (4) other material with a 15 minute fire rating. PEX pipe and fittings are intended for use in areas where the maximum ambient temperature does not exceed 120° F. These pipe and fittings are not intended to be installed in outdoor applications. The PEX pipe and fittings are intended for use in wet-pipe systems only and have not been evaluated for use in drypipe systems. * These products may also be represented by the trade name AquaPEX. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. ** Pipe and fittings Certified as a system using installation and design manual titled "Uponor Residential Fire Sprinkler Systems, AquaSAFE™ System Installation Guide". |
Waterline Products Co. Limited | |
100 Westcreek Blvd, Unit 2 | |
Brampton, ON L6T 5V7 | |
Canada | |
+1 905 453 2400 |
Facility : # 1 China
Surface Burning Characteristics of Building Materials
Product Type | Material Type | Trade Name | Product Standard |
Tubing$ & |
PEX |
Waterline PEX |
CAN/ULC S102.2 |
3/8", 1/2" - 2" |
|||
Flame Spread Rating <= 25 | Smoke Developed Classification <= 50 | ||
$ Certified for blue, natural, red, and white without oxygen barrier. & 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50]. 1/2" - 2" tubing (with insulation), Flame Spread Index and Smoke Developed Index based on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50]. |
|||
Tubing# $ * |
PEX |
Waterline PEX |
ASTM E84 |
3/8", 1/2" - 2" |
|||
Flame Spread Index <= 25 | Smoke Developed Index <= 50 | ||
# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation instructions. The 3/8" tubing is not insulated. $ Certified for blue, natural, red, and white without oxygen barrier. * Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. |
Zurn PEX, Inc. | |
116 Maple Street | |
Commerce, TX 75428 | |
United States | |
903-886-2580 | |
Visit this company's website |
Facility : Harborcreek, PA
Fire Sprinkler Pipe and Fitting Systems
Product Type | Material Type | Trade Name | Product Standard |
Pipe and Fitting System% ** [G] |
MLTPL |
Zurn PEX Fire Protection System |
ANSI/CAN/UL 1821 |
Coupling (BARB x BARB) |
|||
1" barb x 1" barb (QQC55GFX) | 1" barb x 1" barb (QQPC55FX) | 1 1/4" barb x 1 1/4" barb (QQC66GFX) | 1 1/2" barb x 1 1/2" barb (QQC77GFX) |
2" barb x 2" barb (QQC88GFX) | |||
Crimp Coupling |
|||
1" Crimp PEX X 1/2" FPT (QQFSC53GFX) | |||
Crimp Tee |
|||
1" Crimp PEX x 1" Crimp PEX x 1/2" FPT (QQFST553GFX) | |||
Elbow (BARB X BARB) |
|||
1" barb x 1" barb (QQPE55FX) | 1" barb x 1" barb (QQE55GFX) | 1 1/4" barb x 1 1/4" barb (QQE66GFX) | 1 1/2" barb x 1 1/2" barb (QQE77GFX) |
2" barb x 2" barb (QQE88GFX) | |||
Expansion Coupling |
|||
1" EXP PEX x 1/2" FPT (QEFSC53GFX) | |||
Expansion Tee |
|||
1" EXP PEX x 1" EXP PEX x 1/2" FPT (QEFST553FGX) | |||
Female Adapter (BARB x FPT) |
|||
1" barb x 1" FPT (QQUFC55GFX) | 1 1/4" barb x 1 1/4" FPT (QQUFC66GFX) | 1 1/2" barb x 1 1/2" FPT (QQUFC77GFX) | |
Female Sweat Adapter (BARB x SWEAT) |
|||
1" barb x 1" sweat (QQ800CFX) | 1 1/4" barb x 1 1/4" sweat (QQ812GFX) | 1 1/2" barb x 1 1/2" sweat (QQ950GFX) | 2" barb x 2" sweat (QQ1050GFX) |
Fire Sprinkler Coupling |
|||
1" barb x 1/2" FPT (QQFSC53GFX) | |||
Fire Sprinkler Tee (BARB X BARB X FPT) |
|||
1" barb x 1" barb x 1/2" FPT (QQFST553GFX) | |||
Male Adapter (BARB X MPT) |
|||
1" barb x 1" MPT (QQMC55GFX) | 1" barb x 1" barb MPT (QQPMC55FX) | 1 1/4" barb x 1 1/4" MPT (QQMC66GFX) | 1 1/2" barb x 1 1/2" MPT (QQMC77GFX) |
2" barb x 2" MPT (QQMC88GFX) | |||
Male Sweat Adapter (BARB X SWEAT) |
|||
1" barb x 1" sweat (QQ700CFX) | |||
Plug (Barb) |
|||
1" (QQP5GFX) | 1 1/4" (QQP6GFX) | 1 1/2" (QQP7GFX) | 2" (QQP8GFX) |
Reducer Tee (BARB X BARB X BARB) |
|||
1" barb x 1" barb x 1/2" barb (QQT553GFX) | 1" barb x 1" barb x 3/4" barb (QQT554GFX) | 1" barb x 1" barb x 1/2" barb (QQPT553FX) | 1" barb x 1" barb x 3/4" barb (QQPT554FX) |
1 1/4" barb x 1 1/4" barb x 1/2" barb (QQT663GFX) | 1 1/4" barb x 1 1/4" barb x 3/4" barb (QQT664GFX) | 1 1/2" barb x 1 1/2" barb x 3/4" barb (QQT774GFX) | 1 1/2" barb x 1 1/2" barb x 1" barb (QQT775GFX) |
2" barb x 2" barb x 1" barb (QQT885GFX) | |||
Reducing Coupling (BARB x BARB) |
|||
1" barb x 3/4" barb (QQPC54FX) | 1 1/4" barb x 1" barb (QQC65GFX) | 1 1/2" barb x 1 1/4" barb (QQC76GFX) | 2" barb x 1 1/2" barb (QQC87GFX) |
Tee (BARB X BARB X BARB) |
|||
1" barb x 1" barb x 1" barb (QQT555GFX) | 1" barb x 1" barb x 1" barb (QQPT555GFX) | 1 1/4" barb x 1 1/4" barb x 1 1/4" barb (QQT666GFX) | 1 1/2" barb x 1 1/2" barb x 1 1/2" barb (QQT777GFX) |
2" barb x 2" barb x 2" barb (QQT888GFX) | |||
Tubing |
|||
1" – 2" White ZurnPEX | |||
% PEX pipe and fittings are intended for use in multi-purpose piping systems of residential occupancies as defined in ANSI/NFPA 13D, "Installation of Sprinkler Systems in One- and Two- Family Dwellings and Manufactured Homes" and the International Residential Code, Section 2904, and are designed to withstand a working pressure of not less than 130 psi at 120° F. PEX pipe and fittings are intended to be installed in accordance with the requirements specified in the manufacturer’s installation instructions and ANSI/NFPA 13D. Protection is intended to be provided for PEX pipe and fittings in multi-purpose piping systems. The minimum protection should consist of either (1) one layer of 3/8-in. gypsum wallboard, (2) a suspended membrane ceiling with lay-in panels or tiles having a weight of not less than 0.35 lbs per sq ft when installed with metallic support grids, (3) 1/2 in plywood or (4) other material with a 15 minute fire rating. PEX pipe and fittings are intended for use in areas where the maximum ambient temperature does not exceed 120° F. These pipe and fittings are not intended to be installed in outdoor applications. The PEX pipe and fittings are intended for use in wet-pipe systems only and have not been evaluated for use in dry-pipe systems. ** Pipe and fittings Certified as a system using Installation/assembly instructions titled "Zurn PEX Residential Fire Protection Addendum to Plumbing Installation Guide". [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Commerce, TX
Fire Sprinkler Pipe and Fitting Systems
Product Type | Material Type | Trade Name | Product Standard |
Pipe and Fitting System% ** [G] |
PEX |
Zurn PEX Fire Protection System |
ANSI/CAN/UL 1821 |
Tubing |
|||
1" White ZurnPEX | |||
% PEX pipe and fittings are intended for use in multi-purpose piping systems of residential occupancies as defined in ANSI/NFPA 13D, "Installation of Sprinkler Systems in One- and Two- Family Dwellings and Manufactured Homes" and the International Residential Code, Section 2904, and are designed to withstand a working pressure of not less than 130 psi at 120° F. PEX pipe and fittings are intended to be installed in accordance with the requirements specified in the manufacturer’s installation instructions and ANSI/NFPA 13D. Protection is intended to be provided for PEX pipe and fittings in multi-purpose piping systems. The minimum protection should consist of either (1) one layer of 3/8-in. gypsum wallboard, (2) a suspended membrane ceiling with lay-in panels or tiles having a weight of not less than 0.35 lbs per sq ft when installed with metallic support grids, (3) 1/2 in plywood or (4) other material with a 15 minute fire rating. PEX pipe and fittings are intended for use in areas where the maximum ambient temperature does not exceed 120° F. These pipe and fittings are not intended to be installed in outdoor applications. The PEX pipe and fittings are intended for use in wet-pipe systems only and have not been evaluated for use in dry-pipe systems. ** Pipe and fittings Certified as a system using Installation/assembly instructions titled "Zurn PEX Residential Fire Protection Addendum to Plumbing Installation Guide", dated October 2010. [G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Number of matching Manufacturers is 30
Number of matching Products is 2163