NSF Product and Service Listings
These NSF Official Listings are current as of Sunday, December 22, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/food/Listings.asp?Standard=003&Company=09140&
NSF/ANSI 3
Commercial Warewashing Equipment
Commercial Warewashing Equipment
For informational purposes, the estimated racks per hour or dishes per hour for NSF/ANSI 3 Certified dishwashers can be calculated as follows:
Racks per Hour for Stationary Rack Dishwashers = 3600(NR) / TC
Racks per Hour for Rack Conveyor Dishwashers = (CS)(60) / RL
Dishes per Hour for Rackless Conveyor Dishwashers = (120)(CS)(CW) / PD
Water Consumption (gallons per hour) for Stationary Rack Dishwashers = (GPC)(RPH)
Water Consumption (gallons per hour) for Conveyor Dishwashers = (GPM)(60)
Where: CS = Conveyor speed measured in feet per minute
CW = Conveyor width measured in inches
GPC = Gallons per cycle
GPM = Gallons per minute
NR = Number of racks the dishwasher is designed to hold per cycle
PD = Distance between pegs measured in inches, center to center of the peg, in the direction of conveyor travel
RL = Length of the rack measured in feet
RPH = Racks per hour
TC = Total cycle time measured in seconds
The total cycle time includes wash, rinse, dwell, and load times. Load times will vary depending on the type of dishwasher. Estimated load times commonly used for specific types of dishwashers are as follows:
door type (straight thru) - 5 seconds
door type (corner) - 7 seconds
hood type - 8 seconds
front opening type - 30 seconds
CMA Dishmachines | |
17707 Valley View Avenue | |
Cerritos, CA 90703 | |
United States | |
800-854-6417 | |
714-898-8781X 259 |
Facility : Cerritos, CA
GLASSWASHING MACHINES
Glasswashing Machines |
|
CMA-181GW | |
CMA-181VL | |
GL-X | |
GWX-200 |
STATIONARY RACK DISHWASHING MACHINES
Final Rinse | ||||||||
(20 psi) | Operating Time | |||||||
Model | Rack Size | Flow | Usage | (seconds) | Footnotes | |||
Number | Width | gpm | gph | Wash | Rinse | Dwell | ||
Single Tank Stationary Rack, Chemical Sanitizing |
||||||||
A-1 | 20x20 | 52 | 56 | 57 | 48 | 15 | [1] [2] [6] [7] | |
A-2 | 20x20 | 52 | 74 | 45 | 30 | 15 | [1] [2] [6] [7] | |
A-3 | 20x20 | 52 | 46 | 80 | 55 | 15 | [1] [2] [6] [7] | |
AH-1 | 20x20 | 52 | 56 | 57 | 48 | 15 | [1] [2] [6] [7] | |
AH-2 | 20x20 | 52 | 74 | 45 | 30 | 15 | [1] [2] [6] [7] | |
AH-3 | 20x20 | 52 | 46 | 80 | 55 | 15 | [1] [2] [6] [7] | |
C-1 | 20x20 | 52 | 56 | 57 | 48 | 15 | [1] [2] [6] [7] | |
C-2 | 20x20 | 52 | 74 | 45 | 30 | 15 | [1] [2] [6] [7] | |
C-3 | 20x20 | 52 | 46 | 80 | 55 | 15 | [1] [2] [6] [7] | |
CMA-180 LTC | 20x20 | 50 | 49 | 12 | 0 | [2] [4] | ||
CMA-180 LTCB | 20x20 | 50 | 49 | 12 | 0 | [2] [4] | ||
CMA-180 LTS | 20x20 | 52 | 49 | 12 | 0 | [2] [4] | ||
CMA-180 LTSB | 20x20 | 52 | 49 | 12 | 0 | [2] [4] | ||
CVA-1 | 20x20 | 52 | 35 | 65 | 48 | 7 | [1] [2] [3] [7] | |
CVA-2 | 20x20 | 52 | 46.2 | 53 | 30 | 7 | [1] [2] [3] [7] | |
CVA-3 | 20x20 | 52 | 28.8 | 88 | 55 | 7 | [1] [2] [3] [7] | |
CVA-4 | 20x20 | 52 | 57.5 | 45 | 20 | 7 | [1] [2] [3] [7] | |
CVA-5 | 20x20 | 52 | 65 | 40 | 16 | 7 | [1] [2] [3] [7] | |
EST-AH-1 | 20x20 | 52 | 35 | 65 | 48 | 7 | [1] [2] [3] [6] [7] | |
EST-AH-2 | 20x20 | 52 | 41.74 | 53 | 15 | 7 | [1] [2] [3] [6] [7] | |
EST-AH-3 | 20x20 | 52 | 28.8 | 88 | 55 | 7 | [1] [2] [3] [6] [7] | |
EST-C-1 | 20x20 | 52 | 35 | 65 | 48 | 7 | [1] [2] [3] [6] [7] | |
EST-C-2 | 20x20 | 52 | 41.74 | 53 | 15 | 7 | [1] [2] [3] [6] [7] | |
EST-C-3 | 20x20 | 52 | 28.8 | 88 | 55 | 7 | [1] [2] [3] [6] [7] | |
EST-FL | 20x20 | 52 | 46.2 | 53 | 15 | 7 | [1] [2] [3] [6] [7] | |
EST-VL | 20x20 | 52 | 46.2 | 53 | 15 | 7 | [1] [2] [3] [6] [7] | |
EVA-4 | 20x20 | 52 | 57.5 | 45 | 20 | 7 | [1] [2] [3] [6] [7] | |
EVA-5 | 20x20 | 52 | 65 | 40 | 16 | 7 | [1] [2] [3] [6] [7] | |
EVAC-4 | 20x20 | 52 | 57.5 | 45 | 20 | 7 | [1] [2] [3] [6] [7] | |
EVAC-5 | 20x20 | 52 | 65 | 40 | 16 | 7 | [1] [2] [3] [6] [7] | |
L-1C | 20x20 | 4 | 40 | 58 | 32 | 30 | [1] [2] | |
L-1X | 20x20 | 4 | 40 | 58 | 32 | 30 | [1] [2] [6] | |
L-1X16 | 20x20 | 4 | 40 | 58 | 32 | 30 | [1] [2] [6] | |
S-AH-1 | 20x20 | 52 | 56 | 57 | 48 | 15 | [1] [2] [6] [7] | |
S-AH-2 | 20x20 | 52 | 74 | 45 | 30 | 15 | [1] [2] [6] [7] | |
S-AH-3 | 20x20 | 52 | 46 | 80 | 55 | 15 | [1] [2] [6] [7] | |
VA-1 | 20x20 | 52 | 35 | 65 | 48 | 7 | [1] [2] [3] [7] | |
VA-2 | 20x20 | 52 | 46.2 | 53 | 30 | 7 | [1] [2] [3] [7] | |
VA-3 | 20x20 | 52 | 28.8 | 88 | 55 | 7 | [1] [2] [3] [7] | |
VA-4 | 20x20 | 52 | 57.5 | 45 | 20 | 7 | [1] [2] [3] [7] | |
VA-5 | 20x20 | 52 | 65 | 40 | 16 | 7 | [1] [2] [3] [7] | |
[1] Recirculated pumped rinse minimum 50 ppm available Chlorine or 12.5 ppm iodophor. [2] Suffixes apply to all models: T - Top mount controls; I - Integral scrap trap [3] 1.25 gallons per complete cycle includes .25 gal. fresh water flush. [4] Unit to be installed with a chmical feeder Certified under NSF Standard 29 to provide a minimum of 50 ppm chlorine in the recirculated pumped rinse. Dishmachine to bear the NSF Component Mark. [6] Available with suffix B- Built-on 12KW booster heater for 40°F rise. [7] These models are available either with mechanical timer or with SSC solid-state control timer. |
||||||||
Single Tank Stationary Rack, Hot Water Sanitizing |
||||||||
CMA-180 HTC | 20x20 | N/A | 45.2 | 42 | 12 | 4 | [2] | |
CMA-180 HTCB | 20x20 | N/A | 45.2 | 42 | 12 | 4 | [2] | |
CMA-180 HTS | 20x20 | N/A | 46.9 | 42 | 12 | 4 | [2] | |
CMA-180 HTSB | 20x20 | N/A | 46.9 | 42 | 12 | 4 | [2] | |
CMA-180-T-VL | 20x20 | N/A | 74.4 | 44 | 11 | 0 | ||
CMA-180-THTC | 20x20 | 1.24 | 74.4 | 44 | 11 | 0 | ||
CMA-180-THTCB | 20x20 | 1.24 | 74.4 | 44 | 11 | 0 | ||
CMA-180-THTS | 20x20 | 1.24 | 74.4 | 44 | 11 | 0 | ||
CMA-180-THTSB | 20x20 | 1.24 | 74.4 | 44 | 11 | 0 | ||
CMA-180-VL | 20x20 | N/A | 45.2 | 42 | 12 | 4 | ||
CMA-180VL-FL | 20x20 | N/A | 74.4 | 48 | 12 | 0 | ||
[2] Suffixes apply to all models: T - Top mount controls; I - Integral scrap trap |
||||||||
Undercounter, Hot Water Sanitizing |
||||||||
CMA-180 UC | 20x20 | N/A | 17.95 | 94 | 16 | 10 |
[5] Water consumption 0.96 gallon per cycle.
Facility : Cerritos, CA
GLASSWASHING MACHINES
Glasswashing Machines |
|
CMA-181GW | |
CMA-181VL | |
GL-X | |
GWX-200 |
STATIONARY RACK DISHWASHING MACHINES
Final Rinse | ||||||||
(20 psi) | Operating Time | |||||||
Model | Rack Size | Flow | Usage | (seconds) | Footnotes | |||
Number | Width | gpm | gph | Wash | Rinse | Dwell | ||
Single Tank Stationary Rack, Chemical Sanitizing |
||||||||
A-1 | 20x20 | 52 | 56 | 57 | 48 | 15 | [1] [2] [6] [7] | |
A-2 | 20x20 | 52 | 74 | 45 | 30 | 15 | [1] [2] [6] [7] | |
A-3 | 20x20 | 52 | 46 | 80 | 55 | 15 | [1] [2] [6] [7] | |
AH-1 | 20x20 | 52 | 56 | 57 | 48 | 15 | [1] [2] [6] [7] | |
AH-2 | 20x20 | 52 | 74 | 45 | 30 | 15 | [1] [2] [6] [7] | |
AH-3 | 20x20 | 52 | 46 | 80 | 55 | 15 | [1] [2] [6] [7] | |
C-1 | 20x20 | 52 | 56 | 57 | 48 | 15 | [1] [2] [6] [7] | |
C-2 | 20x20 | 52 | 74 | 45 | 30 | 15 | [1] [2] [6] [7] | |
C-3 | 20x20 | 52 | 46 | 80 | 55 | 15 | [1] [2] [6] [7] | |
CMA-180 LTC | 20x20 | 50 | 49 | 12 | 0 | [2] [4] | ||
CMA-180 LTCB | 20x20 | 50 | 49 | 12 | 0 | [2] [4] | ||
CMA-180 LTS | 20x20 | 50 | 49 | 12 | 0 | [2] [4] | ||
CMA-180 LTSB | 20x20 | 50 | 49 | 12 | 0 | [2] [4] | ||
CVA-1 | 20x20 | 52 | 35 | 65 | 48 | 7 | [1] [2] [3] [7] | |
CVA-2 | 20x20 | 52 | 46.2 | 53 | 30 | 7 | [1] [2] [3] [7] | |
CVA-3 | 20x20 | 52 | 28.8 | 88 | 55 | 7 | [1] [2] [3] [7] | |
CVA-4 | 20x20 | 52 | 57.5 | 45 | 20 | 7 | [1] [2] [3] [7] | |
CVA-5 | 20x20 | 52 | 65 | 40 | 16 | 7 | [1] [2] [3] [7] | |
EST-AH-1 | 20x20 | 52 | 35 | 65 | 48 | 7 | [1] [2] [3] [6] [7] | |
EST-AH-2 | 20x20 | 52 | 41.74 | 53 | 15 | 7 | [1] [2] [3] [6] [7] | |
EST-AH-3 | 20x20 | 52 | 28.8 | 88 | 55 | 7 | [1] [2] [3] [6] [7] | |
EST-C-1 | 20x20 | 52 | 35 | 65 | 48 | 7 | [1] [2] [3] [6] [7] | |
EST-C-2 | 20x20 | 52 | 41.74 | 53 | 15 | 7 | [1] [2] [3] [6] [7] | |
EST-C-3 | 20x20 | 52 | 28.8 | 88 | 55 | 7 | [1] [2] [3] [6] [7] | |
EST-FL | 20x20 | 52 | 46.2 | 53 | 15 | 7 | [1] [2] [3] [6] [7] | |
EST-VL | 20x20 | 52 | 46.2 | 53 | 15 | 7 | [1] [2] [3] [6] [7] | |
EVA-4 | 20x20 | 52 | 57.5 | 45 | 20 | 7 | [1] [2] [3] [6] [7] | |
EVA-5 | 20x20 | 52 | 65 | 40 | 16 | 7 | [1] [2] [3] [6] [7] | |
EVAC-4 | 20x20 | 52 | 57.5 | 45 | 20 | 7 | [1] [2] [3] [6] [7] | |
EVAC-5 | 20x20 | 52 | 65 | 40 | 16 | 7 | [1] [2] [3] [6] [7] | |
L-1C | 20x20 | 4 | 48 | 58 | 32 | 30 | [1] [2] | |
L-1X | 20x20 | 4 | 48 | 58 | 32 | 30 | [1] [2] [6] | |
L-1X16 | 20x20 | 4 | 48 | 58 | 32 | 30 | [1] [2] [6] | |
S-AH-1 | 20x20 | 52 | 56 | 57 | 48 | 15 | [1] [2] [6] [7] | |
S-AH-2 | 20x20 | 52 | 74 | 45 | 30 | 15 | [1] [2] [6] [7] | |
S-AH-3 | 20x20 | 52 | 46 | 80 | 55 | 15 | [1] [2] [6] [7] | |
VA-1 | 20x20 | 52 | 35 | 65 | 48 | 7 | [1] [2] [3] [7] | |
VA-2 | 20x20 | 52 | 46.2 | 53 | 30 | 7 | [1] [2] [3] [7] | |
VA-3 | 20x20 | 52 | 28.8 | 88 | 55 | 7 | [1] [2] [3] [7] | |
VA-4 | 20x20 | 52 | 57.5 | 45 | 20 | 7 | [1] [2] [3] [7] | |
VA-5 | 20x20 | 52 | 65 | 40 | 16 | 7 | [1] [2] [3] [7] | |
[1] Recirculated pumped rinse minimum 50 ppm available Chlorine or 12.5 ppm iodophor. [2] Suffixes apply to all models: T - Top mount controls; I - Integral scrap trap. [3] 1.25 gallons per complete cycle includes .25 gal. fresh water flush. [4] Unit to be installed with a chemical feeder Certified under NSF Standard 29 to provide a minimum of 50 ppm chlorine in the recirculated pumped rinse. Dishmachine to bear the NSF Component Mark. [6] Available with suffix B- Built-on 12KW booster heater for 40°F rise. [7] These models are available either with mechanical timer or with SSC solid-state control timer. |
||||||||
Single Tank Stationary Rack, Hot Water Sanitizing |
||||||||
CMA-180 HTC | 20x20 | N/A | 45.2 | 42 | 12 | 4 | [2] | |
CMA-180 HTCB | 20x20 | N/A | 45.2 | 42 | 12 | 4 | [2] | |
CMA-180 HTS | 20x20 | N/A | 46.9 | 42 | 12 | 4 | [2] | |
CMA-180 HTSB | 20x20 | N/A | 46.9 | 42 | 12 | 4 | [2] | |
CMA-180-T-VL | 20x20 | N/A | 74.4 | 44 | 11 | 0 | ||
CMA-180-THTC | 20x20 | 1.24 | 74.4 | 44 | 11 | 0 | ||
CMA-180-THTCB | 20x20 | 1.24 | 74.4 | 44 | 11 | 0 | ||
CMA-180-THTS | 20x20 | 1.24 | 74.4 | 44 | 11 | 0 | ||
CMA-180-THTSB | 20x20 | 1.24 | 74.4 | 44 | 11 | 0 | ||
CMA-180-VL | 20x20 | N/A | 45.2 | 42 | 12 | 4 | ||
CMA-180VL-FL | 20x20 | N/A | 74.4 | 48 | 12 | 0 | ||
[2] Suffixes apply to all models: T - Top mount controls; I - Integral scrap trap. |
||||||||
Undercounter, Hot Water Sanitizing |
||||||||
CMA-180 UC | 20x20 | N/A | 17.95 | 94 | 16 | 10 |
[5] Water consumption 0.96 gallon per cycle.
Number of matching Manufacturers is 1
Number of matching Products is 114
Processing time was 0 seconds