NSF/ANSI 3
Commercial Warewashing Equipment

Racks per Hour / Dishes per Hour / Water Consumption Calculations

For informational purposes, the estimated racks per hour or dishes per hour for NSF/ANSI 3 Certified dishwashers can be calculated as follows:

Racks per Hour for Stationary Rack Dishwashers = 3600(NR) / TC

Racks per Hour for Rack Conveyor Dishwashers = (CS)(60) / RL

Dishes per Hour for Rackless Conveyor Dishwashers = (120)(CS)(CW) / PD

Water Consumption (gallons per hour) for Stationary Rack Dishwashers = (GPC)(RPH)

Water Consumption (gallons per hour) for Conveyor Dishwashers = (GPM)(60)

Where: CS = Conveyor speed measured in feet per minute
              CW = Conveyor width measured in inches
              GPC = Gallons per cycle
              GPM = Gallons per minute
              NR = Number of racks the dishwasher is designed to hold per cycle
              PD = Distance between pegs measured in inches, center to center of the peg, in the direction of conveyor travel
              RL = Length of the rack measured in feet
              RPH = Racks per hour
              TC = Total cycle time measured in seconds

The total cycle time includes wash, rinse, dwell, and load times. Load times will vary depending on the type of dishwasher. Estimated load times commonly used for specific types of dishwashers are as follows:
door type (straight thru) - 5 seconds
door type (corner) - 7 seconds
hood type - 8 seconds
front opening type - 30 seconds



 
Hobart Corporation 
World Headquarters
701 South Ridge Avenue 
Troy, OH 45374 
United States 
937-332-2836
Visit this company's website

Facility : # 2 Canada


STATIONARY RACK DISHWASHING MACHINES
      Final Rinse    
      (20 psi) Operating Time  
  Model Rack Size Flow Usage (seconds) Footnotes
  Number Width gpm gph Wash Rinse Dwell  

Single Tank Chemical Sanitizing Door
  LT-1 20x20  9.5   70.3   41   22   27   [1] [2]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[2] Final rinse must contain 50 ppm minimum available chlorine.


Facility : # 5 Italy


STATIONARY RACK DISHWASHING MACHINES
      Final Rinse    
      (20 psi) Operating Time  
  Model Rack Size Flow Usage (seconds) Footnotes
  Number Width gpm gph Wash Rinse Dwell  

Undercounter, Chemical Sanitizing, (Pumped Rinse) Centerline Series
  CUL 20x20  N/A   20.1   90   15   15   

Undercounter, Hot Water Sanitizing, (Pumped Rinse) Centerline Series
  CUH 20x20  N/A   20.3   90   15   15   [1]
 
[1] Final rinse water is supplied through separate cold-water line.


Facility : # 6 Italy


STATIONARY RACK DISHWASHING MACHINES
      Final Rinse    
      (20 psi) Operating Time  
  Model Rack Size Flow Usage (seconds) Footnotes
  Number Width gpm gph Wash Rinse Dwell  

Centerline Series - Chemical Sanitizing Rack
  CDL 20x20  N/A   43.9   35   15   15   

Centerline Series - Hot Water Sanitizing Rack
  CDH 20x20  N/A   37.4   30   16   19   


Facility : Danville, KY


STATIONARY RACK DISHWASHING MACHINES
      Final Rinse    
      (20 psi) Operating Time  
  Model Rack Size Flow Usage (seconds) Footnotes
  Number Width gpm gph Wash Rinse Dwell  

Single Tank Chemical Sanitizing Door
  LT-1 20x20  9.5   70.3   41   22   27   [1] [2]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[2] Final rinse must contain 50 ppm minimum available chlorine.

Single Tank Chemical Sanitizing Door (Dual Sanitizing Mode Machines)
  AM15 20x20  4.4   47.4   38   10   2   [1] [2] [3] [4] [5] [6]
  AM15F 20x20  4.4   33   38   10   2   [1] [2] [4] [5] [6]
  AM15T 20x20  4.4   47.4   38   10   2   [1] [2] [3] [4] [5] [6] [7]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[2] Final rinse must contain 50 ppm minimum available chlorine.
[3] Corner model is rated 40.8 gph for hot and 46 gph for chemical sanitizing.
[4] Includes post-wash dwell (2 seconds).
[5] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
    Washing Machine. Please reference this model's Listing under Stationary Rack Pot, Pan
    and Utensil Washing Machines for this model's specifications for that mode of operation.
[6] Available with power vent fan option.
[7] Available with optional front loading kit rated with 33 gph for chemical sanitizing and
    30 gph hot water sanitizing.

Single Tank Door (Dual Sanitizing Mode Machines)
  AM15 20x20  4.4   42.3   38   10   9   [1] [3] [5] [8]
  AM15F 20x20  4.4   30   38   10   9   [1] [5] [8]
  AM15T 20x20  4.4   42.3   38   10   9   [1] [3] [5] [7] [8]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[3] Corner model is rated 40.8 gph for hot and 46 gph for chemical sanitizing.
[5] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
    Washing Machine. Please reference this model's Listing under Stationary Rack Pot, Pan
    and Utensil Washing Machines for this model's specifications for that mode of operation.
[7] Available with optional front loading kit rated with 33 gph for chemical sanitizing and
    30 gph hot water sanitizing.
[8] Includes post-wash dwell (2 seconds) and post-rinse dwell (7 seconds).

Single Tank Door, Chemical Sanitizing, Fresh Water Rinse
  AM15SCB 20x20  4.4   38.7   38   10   14   [1] [2] [4] [5] [9] [10] [11] [12]
  AM15SCB 20x20  4.4   47.4   38   10   2   [1] [2] [3] [4] [5] [7] [9]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[2] Final rinse must contain 50 ppm minimum available chlorine.
[3] Corner model is rated 40.8 gph for hot and 46 gph for chemical sanitizing.
[4] Includes post-wash dwell (2 seconds).
[5] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
    Washing Machine. Please reference this model's Listing under Stationary Rack Pot, Pan
    and Utensil Washing Machines for this model's specifications for that mode of operation.
[7] Available with optional front loading kit rated with 33 gph for chemical sanitizing and
    30 gph hot water sanitizing.
[9] May be provided with increased rinse times for reduced pressure as follows: 13 sec at 15
    PSI, 14 sec at 12 PSI, 15 sec at 10 PSI.
[10] May be provided with optional self-contained condensing system.
[11] Corner model is rated 37.9 GPH.
[12] Available with optional front loading kit rated 28.4 GPH.

Single Tank Door, Chemical Sanitizing, Fresh Water Rinse, Two Temperature
  LXGePR 20x20  N/A   21.1   56   8   9   [1] [13]
  LXGePR 20x20  N/A   33.1   56   15   23   [1] [13] [14]
  LXeC 20x20  N/A   19.2   85   10   10   [1] [13] [15]
  LXePR 20x20  N/A   33.1   56   15   23   [1] [13] [14] [15] [16]
  LXePR 20x20  N/A   21.1   56   8   9   [1] [13] [15] [16]
  LXePR 20x20  N/A   26.2   85   15   24   [1] [13] [14] [15]
  LXePR 20x20  N/A   16.7   85   8   9   [1] [13] [15]
  LXeSPR 20x20  N/A   16.7   85   8   9   [1] [13] [15]
  LXeSPR 20x20  N/A   21.1   56   8   9   [1] [13] [15] [16]
  LXeSPR 20x20  N/A   33.1   56   15   23   [1] [13] [14] [15] [16]
  LXeSPR 20x20  N/A   26.2   85   15   24   [1] [13] [14] [15]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[13] Minimum 50 ppm available chlorine, minimum 120°F.
[14] Post rinse switch "ON" (8 second sani rinse, 7 second post sani rinse).
[15] Corner model is rated 47.6 gph for hot and 53.5 gph for chemical sanitizing.
[16] Optional short cycle selection.

Single Tank Door, Chemical Sanitizing, Pumped Fresh Water Rinse
  AM16SCB 20x20  N/A   47.9   30   10   5   [2] [5] [17]
  AM16SCBX 20x20  N/A   16.9   120   10   5   [5] [18]
  AM16VLSCB 20x20  N/A   39.2   30   10   17   [2] [5] [17] [19]
  AM16VLSCBX 20x20  N/A   15.5   120   10   17   [5] [18] [20]
 
[2] Final rinse must contain 50 ppm minimum available chlorine.
[5] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
    Washing Machine. Please reference this model's Listing under Stationary Rack Pot, Pan
    and Utensil Washing Machines for this model's specifications for that mode of operation.
[17] Corner models rated 46.6 GPH for AM16SCB/AM16SCBX and 29 GPH for AM16VLSCB/AM16VLSCBX.
[18] Includes condensing period (20 seconds).
[19] Includes condensing period (12 seconds).
[20] Corner models rated 39.2 GPH for AM16BAS/AM16BASX, AM16TBAS/AM16TBASX, 34.4 GPH for
     AM16ASR, AM16TASR, 29 GPH for AM16VLBAS/AM16VLBASX, 26.3 GPH for AM16VLTBAS/AM16VLTBASX,
     27 GPH for AM16VLADV, 24.3 for AM16VLTADV and AM16SVLT.

Single Tank Door, Hot Water Sanitizing, (Pumped Rinse)
  AM15SVL 20x20  N/A   22.2   58   10   47   [1] [5] [21] [22] [23]
  AM15SVLT 20x20  N/A   22.2   58   10   47   [1] [5] [7] [21] [22] [23]
  AM15VL 20x20  4.4   28.6   38   10   39   [1] [5] [21] [22] [24]
  AM15VLF 20x20  4.4   22   38   10   39   [1] [5] [22] [24]
  AM15VLT 20x20  4.4   28.6   38   10   39   [1] [5] [7] [21] [22] [24]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[5] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
    Washing Machine. Please reference this model's Listing under Stationary Rack Pot, Pan
    and Utensil Washing Machines for this model's specifications for that mode of operation.
[7] Available with optional front loading kit rated with 33 gph for chemical sanitizing and
    30 gph hot water sanitizing.
[21] Corner model is rated 27.8 gph.
[22] Final rinse water is supplied through separate cold water line.
[23] Note – water consumption is from building cold water supply.
[24] Includes Pot-wash dwell (2 seconds), post-rinse dwell (7 seconds) and condensing period
     (30 seconds).

Single Tank Door, Hot Water Sanitizing, Pumped Fresh Water Rinse
  AM16ASR 20x20  N/A   35.1   30   10   23   [5] [20]
  AM16BAS 20x20  N/A   39.8   30   10   15   [5] [20]
  AM16BASX 20x20  N/A   40.5   30   10   15   [5] [12] [17]
  AM16SVLT 20x20  N/A   24.3   30   10   53   [5] [20] [25]
  AM16TASR 20x20  N/A   35.1   30   10   23   [5] [20]
  AM16TBAS 20x20  N/A   39.8   30   10   15   [5] [20]
  AM16TBASX 20x20  N/A   40.5   30   10   15   [5] [12] [17]
  AM16VLADV 20x20  N/A   27   30   10   43   [5] [18] [20]
  AM16VLBAS 20x20  N/A   30.4   30   10   35   [5] [18] [20]
  AM16VLBASX 20x20  N/A   27   30   10   43   [4] [5] [10] [17]
  AM16VLTADV 20x20  N/A   24.3   30   10   53   [5] [20] [25]
  AM16VLTBAS 20x20  N/A   27   30   10   45   [5] [20] [25]
  AM16VLTBASX 20x20  N/A   24.3   30   10   53   [5] [11] [12] [17]
 
[4] Includes post-wash dwell (2 seconds).
[5] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
    Washing Machine. Please reference this model's Listing under Stationary Rack Pot, Pan
    and Utensil Washing Machines for this model's specifications for that mode of operation.
[10] May be provided with optional self-contained condensing system.
[11] Corner model is rated 37.9 GPH.
[12] Available with optional front loading kit rated 28.4 GPH.
[17] Corner models rated 46.6 GPH for AM16SCB/AM16SCBX and 29 GPH for AM16VLSCB/AM16VLSCBX.
[18] Includes condensing period (20 seconds).
[20] Corner models rated 39.2 GPH for AM16BAS/AM16BASX, AM16TBAS/AM16TBASX, 34.4 GPH for
     AM16ASR, AM16TASR, 29 GPH for AM16VLBAS/AM16VLBASX, 26.3 GPH for AM16VLTBAS/AM16VLTBASX,
     27 GPH for AM16VLADV, 24.3 for AM16VLTADV and AM16SVLT.
[25] Includes condensing period (30 seconds).

Single Tank Door, Pumped Fresh Water Rinse, Two Temperature
  LXGeR 20x20  N/A   14.3   56   8   56   [1] [23]
  LXeH 20x20  N/A   18.5   85   10   15   [1] [15]
  LXeR 20x20  N/A   12.4   85   8   53   [1] [15] [23]
  LXeR 20x20  N/A   14.3   56   8   56   [1] [15] [16] [23]
  LXeSR 20x20  N/A   14.3   56   8   56   [1] [15] [16] [23]
  LXeSR 20x20  N/A   12.4   85   8   53   [1] [15] [23]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[15] Corner model is rated 47.6 gph for hot and 53.5 gph for chemical sanitizing.
[16] Optional short cycle selection.
[23] Note – water consumption is from building cold water supply.


STATIONARY RACK POT, PAN, AND UTENSIL WASHING MACHINES
      Final Rinse    
      (20 psi) Operating Time  
  Model Rack Size Flow Usage (seconds) Footnotes
  Number Width gpm gph Wash Rinse Dwell  

Single Tank Chemical Sanitizing Door (Dual Sanitizing Mode Machines)
  AM15 20x20  4.4   18.9   120   10   2   [1] [2] [3] [4] [5] [6]
  AM15F 20x20  4.4   16.1   120   10   2   [1] [3] [4] [5] [6]
  AM15T 20x20  4.4   18.9   120   10   2   [1] [2] [3] [4] [5] [6] [7]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[2] Corner model is rated 17.5 gph for hot and 18.2 gph for chemical sanitizing.
[3] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
    Washing Machine. Please reference this model's Listing under Stationary Rack Dishwashing
    Machines for this model's specifications for that mode of operation.
[4] Includes post-wash dwell (2 seconds).
[5] Final rinse must contain 50 ppm minimum available chlorine.
[6] Available with power vent fan option.
[7] Available with optional front loading kit rated with 16.1 gph for chemical sanitizing
    and 15.4 gph hot water sanitizing.

Single Tank Door (Dual Sanitizing Mode Machines)
  AM15 20x20  4.4   18.2   120   10   9   [1] [2] [3] [6] [8]
  AM15F 20x20  4.4   15.4   120   10   9   [1] [3] [6] [8]
  AM15T 20x20  4.4   18.2   120   10   9   [1] [2] [3] [6] [7] [8]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[2] Corner model is rated 17.5 gph for hot and 18.2 gph for chemical sanitizing.
[3] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
    Washing Machine. Please reference this model's Listing under Stationary Rack Dishwashing
    Machines for this model's specifications for that mode of operation.
[6] Available with power vent fan option.
[7] Available with optional front loading kit rated with 16.1 gph for chemical sanitizing
    and 15.4 gph hot water sanitizing.
[8] Includes post-wash dwell (4 seconds) and post-rinse dwell (5 seconds).

Single Tank Door, Chemical Sanitizing, Fresh Water Rinse
  AM15SCB 20x20  4.4   18.9   120   10   2   [1] [3] [4] [5] [9]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[3] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
    Washing Machine. Please reference this model's Listing under Stationary Rack Dishwashing
    Machines for this model's specifications for that mode of operation.
[4] Includes post-wash dwell (2 seconds).
[5] Final rinse must contain 50 ppm minimum available chlorine.
[9] May be provided with increased rinse times for reduced pressure as follows: 13 sec at 15
    PSI, 14 sec at 12 PSI, 15 sec at 10 PSI.

Single Tank Door, Chemical Sanitizing, Pumped Fresh Water Rinse
  AM16SCB 20x20  N/A   16.9   120   10   5   [5] [10]
  AM16SCBX 20x20  N/A   16.9   120   10   5   [5] [10]
  AM16VLSCB 20x20  N/A   15.5   120   10   17   [5] [10] [11]
  AM16VLSCBX 20x20  N/A   15.5   120   10   17   [5] [10] [11]
 
[5] Final rinse must contain 50 ppm minimum available chlorine.
[10] Corner models rated 16.9 GPH for AM16SCB/AM16SCBX and 13.5 GPH for AM16VLSCB/AM16VLSCBX.
[11] Includes condensing period (12 seconds).

Single Tank Door, Hot Water Sanitizing, (Pumped Rinse)
  AM15SVL 20x20  N/A   14.6   120   10   45   [1] [12] [13] [14]
  AM15SVLT 20x20  N/A   14.6   120   10   45   [1] [7] [12] [13] [14]
  AM15VL 20x20  4.4   14.6   120   10   39   [1] [12] [13] [15]
  AM15VLF 20x20  4.4   13.2   120   10   39   [1] [13] [15]
  AM15VLT 20x20  4.4   14.6   120   10   39   [1] [7] [12] [13] [15]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[7] Available with optional front loading kit rated with 16.1 gph for chemical sanitizing
    and 15.4 gph hot water sanitizing.
[12] Corner model is rated same as straight thru model at 14.6 gph.
[13] Final rinse water is supplied through separate cold water line.
[14] Pumped final rinse, no pressure gauge required.
[15] Includes Pot-wash dwell (2 seconds), post-rinse dwell (7 seconds) and condensing period
     (30 seconds).

Single Tank Door, Hot Water Sanitizing, Pumped Final Rinse
  PW10 22.3x28.7  N/A   23.8   120   10   13   [14] [16]
  PW10ER 22.3x28.7  N/A   15.4   120   10   114   [14] [16] [17]
  PW10S 22.3x28.7  N/A   17.7   120   10   13   [14] [16]
  PW10SER 22.3x28.7  N/A   17.7   120   10   119   [14] [16] [17]
  PW20 26.1x48  N/A   47   120   10   16   [14] [16]
  PW20ER 26.1x48  N/A   36.5   120   12   114   [14] [16] [17]
  PWV 22.3x28.7  N/A   23.8   120   10   13   [14] [16]
  PWVER 22.3x28.7  N/A   15.4   120   10   114   [14] [16] [17]
  PWVXL 26.1x48  N/A   47   120   10   16   [14] [16]
  PWVXLER 26.1x48  N/A   36.5   120   12   114   [14] [16] [17]
 
[14] Pumped final rinse, no pressure gauge required.
[16] Unit is able to be set at 240 second and 480 second wash cycles.
[17] Final rinse water consumption is from building cold water supply.

Single Tank Door, Hot Water Sanitizing, Pumped Fresh Water Rinse
  AM16ASR 20x20  N/A   14.9   120   10   23   [18]
  AM16BAS 20x20  N/A   16.2   120   10   15   [18]
  AM16BASX 20x20  N/A   16.2   120   10   15   [18]
  AM16SVLT 20x20  N/A   12.8   120   10   53   [18] [19]
  AM16TASR 20x20  N/A   14.9   120   10   23   [18]
  AM16TBAS 20x20  N/A   16.2   120   10   15   [18]
  AM16TBASX 20x20  N/A   16.2   120   10   15   [18]
  AM16VLADV 20x20  N/A   13.5   120   10   43   [18] [20]
  AM16VLBAS 20x20  N/A   14.2   120   10   35   [18] [20]
  AM16VLBASX 20x20  N/A   14.2   120   10   35   [18] [20]
  AM16VLTADV 20x20  N/A   12.8   120   10   53   [18] [19]
  AM16VLTBAS 20x20  N/A   13.5   120   10   45   [18] [19]
  AM16VLTBASX 20x20  N/A   13.5   120   10   45   [18] [19]
 
[18] Corner models rated 15.5 GPH for AM16BAS/AM16BASX, AM16TBAS/AM16TBASX, 14.9 GPH for
     AM16ASR,
     AM16TASR, 13.5 GPH for AM16VLBAS/AM16VLBASX, 12.8 GPH for AM16VLTBAS/AM16VLTBASX, 13.5
     GPH for
     AM16VLADV, 12.2 for AM16VLTADV and AM16SVLT.
[19]  Includes condensing period (30 seconds).
[20] Includes condensing period (20 seconds).

Single Tank Hot Water Sanitizing Door
  LXeR 20x20  N/A   6.8   215   8   52   [1] [21]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[21] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
     Washing Machine when operated with the 215 second wash cycle. Please reference this
     model's Listing under Stationary Rack Dishwashing Machines for this model's
     specifications for that mode of operation.


Facility : Troy, OH


CONVEYOR DISHWASHING MACHINES
      Final Rinse    
      (20 psi) Conveyor Speed  
  Model Conveyor Flow Usage (Max.) Footnotes
  Number Width gpm gph (ft/min.)  

Multiple Tank Rackless Conveyor, Chemical Sanitizing[1]
  FT1000iLT 29.875  N/A   150.8   8.5   [3]
 
[1] The peg spacing for rackless conveyor dishwashers is 2.173 inches, center to center.
[3] May include suffix BD for optional blower-dryer.

Multiple Tank Rackless Conveyor, Hot Water Sanitizing[1]
  FT1000eER 29.875  N/A   57.6   8.5   [2] [3] [4] [5] [6]
  FT1000eADV 29.875  N/A   57.6   8.5   [5] [7]
  FT1000e 29.875  N/A   57.6   8.5   [5] [6]
  FT1000eER 29.875  N/A   57.6   8.5   [2] [3] [5]
  FT1000eADV 29.875  N/A   87.6   8.5   [5] [6] [7]
  FT1000e 29.875  N/A   57.6   8.5   [4] [5]
  FT1000i 29.875  N/A   77   8.5   [2] [3] [4]
 
[1] The peg spacing for rackless conveyor dishwashers is 2.173 inches, center to center.
[2] Includes Energy Recovery Unit.
[3] May include suffix BD for optional blower-dryer.
[4] May be provided with fresh water rinse system and pressure gauge. Final rinse pressure
    20 ± 5 PSI.
[5] May be rated 1.5 gpm/90 gph or 2.0 gpm/120 gph.
[6] Provided with chamber 6 inches higher than standard.
[7] Provided with energy recovery unit with heat pump.

Single Tank Rackless Conveyor, Chemical Sanitizing[1]
  FT1000SiLT 29.875  N/A   150.8   6.3   [3]
 
[1] The peg spacing for rackless conveyor dishwashers is 2.173 inches, center to center.
[3] May include suffix BD for optional blower-dryer.

Single Tank Rackless Conveyor, Hot Water Sanitizing[1]
  FT1000SeER 29.875  N/A   57.6   6.3   [2] [3] [5] [6]
  FT1000Se 29.875  N/A   57.6   6.3   [4] [5]
  FT1000SeER 29.875  N/A   57.6   6.3   [2] [3] [4] [5]
  FT1000Se 29.875  N/A   57.6   6.3   [5] [6]
  FT1000Si 29.875  N/A   77   6.3   [2] [3] [4] [5]
 
[1] The peg spacing for rackless conveyor dishwashers is 2.173 inches, center to center.
[2] Includes Energy Recovery Unit.
[3] May include suffix BD for optional blower-dryer.
[4] May be provided with fresh water rinse system and pressure gauge. Final rinse pressure
    20 ± 5 PSI.
[5] May be rated 1.5 gpm/90 gph or 2.0 gpm/120 gph.
[6] Provided with chamber 6 inches higher than standard.


Facility : Lancaster, PA


STATIONARY RACK DISHWASHING MACHINES
      Final Rinse    
      (20 psi) Operating Time  
  Model Rack Size Flow Usage (seconds) Footnotes
  Number Width gpm gph Wash Rinse Dwell  

Single Tank Chemical Sanitizing Door (Dual Sanitizing Mode Machines)
  AM15 20x20  4.4   47.4   38   10   2   [1] [2] [3] [4] [5] [6]
  AM15F 20x20  4.4   33   38   10   2   [1] [2] [4] [5] [6]
  AM15T 20x20  4.4   47.4   38   10   2   [1] [2] [3] [4] [5] [6] [7]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[2] Final rinse must contain 50 ppm minimum available chlorine.
[3] Corner model is rated 40.8 gph for hot and 46 gph for chemical sanitizing.
[4] Includes post-wash dwell (2 seconds).
[5] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
    Washing Machine. Please reference this model's Listing under Stationary Rack Pot, Pan
    and Utensil Washing Machines for this model's specifications for that mode of operation.
[6] Available with power vent fan option.
[7] Available with optional front loading kit rated with 33 gph for chemical sanitizing and
    30 gph hot water sanitizing.

Single Tank Door (Dual Sanitizing Mode Machines)
  AM15 20x20  4.4   42.3   38   10   9   [1] [3] [5] [8]
  AM15F 20x20  4.4   30   38   10   9   [1] [5] [8]
  AM15T 20x20  4.4   42.3   38   10   9   [1] [3] [5] [7] [8]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[3] Corner model is rated 40.8 gph for hot and 46 gph for chemical sanitizing.
[5] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
    Washing Machine. Please reference this model's Listing under Stationary Rack Pot, Pan
    and Utensil Washing Machines for this model's specifications for that mode of operation.
[7] Available with optional front loading kit rated with 33 gph for chemical sanitizing and
    30 gph hot water sanitizing.
[8] Includes post-wash dwell (2 seconds) and post-rinse dwell (7 seconds).

Single Tank Door, Chemical Sanitizing, Fresh Water Rinse
  AM15SCB 20x20  4.4   38.7   38   10   14   [1] [2] [4] [5] [9] [10] [11] [12]
  AM15SCB 20x20  4.4   47.4   38   10   2   [1] [2] [3] [4] [5] [7] [12]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[2] Final rinse must contain 50 ppm minimum available chlorine.
[3] Corner model is rated 40.8 gph for hot and 46 gph for chemical sanitizing.
[4] Includes post-wash dwell (2 seconds).
[5] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
    Washing Machine. Please reference this model's Listing under Stationary Rack Pot, Pan
    and Utensil Washing Machines for this model's specifications for that mode of operation.
[7] Available with optional front loading kit rated with 33 gph for chemical sanitizing and
    30 gph hot water sanitizing.
[9] May be provided with optional self-contained condensing system.
[10] Corner model is rated 37.9 GPH.
[11] Available with optional front loading kit rated 28.4 GPH.
[12] May be provided with increased rinse times for reduced pressure as follows: 13 sec at 15
     PSI, 14 sec at 12 PSI, 15 sec at 10 PSI.

Single Tank Door, Hot Water Sanitizing, (Pumped Rinse)
  AM15SVL 20x20  N/A   22.2   58   10   47   [1] [5] [13] [14] [15]
  AM15SVLT 20x20  N/A   22.2   58   10   47   [1] [5] [7] [13] [14] [15]
  AM15VL 20x20  4.4   28.6   38   10   39   16] [1] [5] [13] [14]
  AM15VLF 20x20  4.4   22   38   10   39   16] [1] [5] [14]
  AM15VLT 20x20  4.4   28.6   38   10   39   16] [1] [5] [7] [13] [14]
 
16] Includes Pot-wash dwell (2 seconds), post-rinse dwell (7 seconds) and condensing period
    (30 seconds).
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[5] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
    Washing Machine. Please reference this model's Listing under Stationary Rack Pot, Pan
    and Utensil Washing Machines for this model's specifications for that mode of operation.
[7] Available with optional front loading kit rated with 33 gph for chemical sanitizing and
    30 gph hot water sanitizing.
[13] Corner model is rated 27.8 gph.
[14] Final rinse water is supplied through separate cold water line.
[15] Note – water consumption is from building cold water supply.


STATIONARY RACK POT, PAN, AND UTENSIL WASHING MACHINES
      Final Rinse    
      (20 psi) Operating Time  
  Model Rack Size Flow Usage (seconds) Footnotes
  Number Width gpm gph Wash Rinse Dwell  

Single Tank Chemical Sanitizing Door (Dual Sanitizing Mode Machines)
  AM15 20x20  4.4   18.9   120   10   2   [1] [2] [3] [4] [5] [6]
  AM15F 20x20  4.4   16.1   120   10   2   [1] [3] [4] [5] [6]
  AM15T 20x20  4.4   18.9   120   10   2   [1] [2] [3] [4] [5] [6] [7]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[2] Corner model is rated 17.5 gph for hot and 18.2 gph for chemical sanitizing.
[3] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
    Washing Machine. Please reference this model's Listing under Stationary Rack Dishwashing
    Machines for this model's specifications for that mode of operation.
[4] Includes post-wash dwell (2 seconds).
[5] Final rinse must contain 50 ppm minimum available chlorine.
[6] Available with power vent fan option.
[7] Available with optional front loading kit rated with 16.1 gph for chemical sanitizing
    and 15.4 gph hot water sanitizing.

Single Tank Door (Dual Sanitizing Mode Machines)
  AM15 20x20  4.4   18.2   120   10   9   [1] [2] [3] [6] [8]
  AM15F 20x20  4.4   15.4   120   10   9   [1] [3] [6] [8]
  AM15T 20x20  4.4   18.2   120   10   9   [1] [2] [3] [6] [7] [8]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[2] Corner model is rated 17.5 gph for hot and 18.2 gph for chemical sanitizing.
[3] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
    Washing Machine. Please reference this model's Listing under Stationary Rack Dishwashing
    Machines for this model's specifications for that mode of operation.
[6] Available with power vent fan option.
[7] Available with optional front loading kit rated with 16.1 gph for chemical sanitizing
    and 15.4 gph hot water sanitizing.
[8] Includes post-wash dwell (4 seconds) and post-rinse dwell (5 seconds).

Single Tank Door, Chemical Sanitizing, Fresh Water Rinse
  AM15SCB 20x20  4.4   18.9   120   10   2   [1] [3] [4] [5] [9]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[3] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
    Washing Machine. Please reference this model's Listing under Stationary Rack Dishwashing
    Machines for this model's specifications for that mode of operation.
[4] Includes post-wash dwell (2 seconds).
[5] Final rinse must contain 50 ppm minimum available chlorine.
[9] May be provided with increased rinse times for reduced pressure as follows: 13 sec at 15
    PSI, 14 sec at 12 PSI, 15 sec at 10 PSI.

Single Tank Door, Hot Water Sanitizing, (Pumped Rinse)
  AM15SVL 20x20  N/A   14.6   120   10   45   [1] [10] [11] [12]
  AM15SVLT 20x20  N/A   14.6   120   10   45   [1] [7] [10] [11] [12]
  AM15VL 20x20  4.4   14.6   120   10   39   [1] [10] [11] [13]
  AM15VLF 20x20  4.4   13.2   120   10   39   [1] [11] [13]
  AM15VLT 20x20  4.4   14.6   120   10   39   [1] [7] [10] [11] [13]
 
[1] Optional tabling and shelving fully complying with NSF Standard 2 may be provided.
[7] Available with optional front loading kit rated with 16.1 gph for chemical sanitizing
    and 15.4 gph hot water sanitizing.
[10] Corner model is rated same as straight thru model at 14.6 gph.
[11] Final rinse water is supplied through separate cold water line.
[12] Pumped final rinse, no pressure gauge required.
[13] Includes Pot-wash dwell (2 seconds), post-rinse dwell (7 seconds) and condensing period
     (30 seconds).


Facility : Owen Sound, Ontario, Canada


CONVEYOR DISHWASHING MACHINES
      Final Rinse    
      (20 psi) Conveyor Speed  
  Model Conveyor Flow Usage (Max.) Footnotes
  Number Width gpm gph (ft/min.)  

Multiple Tank Rack Conveyor, Chemical Sanitizing
  CL64e 20x20  2.2   132   9.5   [1] [2] [3] [4] [5] [6]
  CL64eN 20x20  2.2   132   9.5   [1] [2] [3] [4] [5] [6] [8] [9] [10]
  CLCS86e 20x20  2.2   132   9.5   [1] [2] [3] [4] [5] [6]
  CLCS86eN 20x20  2.2   132   9.5   [1] [2] [3] [4] [5] [8] [9] [10]
  CLPS86e 20x20  2.2   132   9.5   [1] [2] [3] [4] [5] [6]
  CLPS86eN 20x20  2.2   132   9.5   [1] [2] [3] [4] [5] [6] [8] [9] [10]
 
[1] Final rinse must contain 50 ppm minimum available chlorine.
[2] Unit available with a corner unloader.
[3] CLe Series dishwashing machines are also used when incorporating the "Fast Rack" or
    "FRC" transport system.  This system may incorporate one or more CLe Series dishwshing
    machine(s), fully complying with NSF Standard 2.  Model numbers would then become FRCL
    models rather than CLe models and would indicate the total length of the dishwashing
    section(s).
[4] Unit also accepted when operated as a chemical sanitizing dishwasher provided with a
    chemical sanitizing pump which is Listed under NSF Standard 29; "Low Temp" must be
    displayed on the control panel when the machine is first powered up.  Minimum wash and
    rinse temperature is 130°F.  Minimum final rinse temperature is 120°F.
[5] May be provided with wash chamber 6 inches higher than standard height 24 inches.
[6] May be provided with a blower/dryer unit option.
[8] Machine also available with “ER” denoting Drain Water Energy Recovery.
[9] Machine also available with “ADV” denoting Automatic Soil Removal.
[10] Machine rated for Pot and Pan washing. Conveyor speed and water consumption shown is the
     same for both regular running mode and Pot and Pan mode except that while in Pot and Pan
     mode, the conveyor will “dwell” 2 times for a specified amount of time (30 second
     minimum each dwell). During this dwell, the rinse is turned off until 2 seconds before
     the conveyor indexes. In Pot and Pan mode an average of 43 racks per hour can be run.

Multiple Tank Rack Conveyor, Hot Water Sanitizing
  CL64e 20x20  2.2   132   9.5   [2] [3] [5] [6] [7]
  CL64eN 20x20  2.2   132   9.5   [2] [3] [5] [6] [7] [8] [9] [10]
  CLCS86e 20x20  2.2   132   9.5   [2] [3] [5] [6] [7]
  CLCS86eN 20x20  2.2   132   9.5   [2] [3] [5] [6] [7] [8] [10]
  CLPS86e 20x20  2.2   132   9.5   [2] [3] [5] [6] [7]
  CLPS86eN 20x20  2.2   132   9.5   [2] [3] [5] [6] [7] [8] [9] [10]
 
[2] Unit available with a corner unloader.
[3] CLe Series dishwashing machines are also used when incorporating the "Fast Rack" or
    "FRC" transport system.  This system may incorporate one or more CLe Series dishwshing
    machine(s), fully complying with NSF Standard 2.  Model numbers would then become FRCL
    models rather than CLe models and would indicate the total length of the dishwashing
    section(s).
[5] May be provided with wash chamber 6 inches higher than standard height 24 inches.
[6] May be provided with a blower/dryer unit option.
[7] May have suffix "R" indicating energy recovery unit option.
[8] Machine also available with “ER” denoting Drain Water Energy Recovery.
[9] Machine also available with “ADV” denoting Automatic Soil Removal.
[10] Machine rated for Pot and Pan washing. Conveyor speed and water consumption shown is the
     same for both regular running mode and Pot and Pan mode except that while in Pot and Pan
     mode, the conveyor will “dwell” 2 times for a specified amount of time (30 second
     minimum each dwell). During this dwell, the rinse is turned off until 2 seconds before
     the conveyor indexes. In Pot and Pan mode an average of 43 racks per hour can be run.

Single Tank Rack Conveyor, Chemical Sanitizing
  CL44e 20x20  2.1   126   5.6   [1] [2] [3] [4] [5] [6]
  CL44eN 20x20  2.1   126   5.6   [1] [2] [3] [4] [5] [6] [8] [9] [10]
  CL54e 20x20  2.3   138   6.8   [1] [2] [3] [4] [5] [6]
  CL54eN 20x20  2.3   138   6.8   [1] [2] [3] [4] [5] [6] [8] [9] [10]
  CLCS66e 20x20  2.1   126   5.6   [1] [2] [3] [4] [5] [6]
  CLCS66eN 20x20  2.1   126   5.6   [1] [2] [3] [4] [5] [6] [8] [9] [10]
  CLCS76e 20x20  2.3   138   6.8   [1] [2] [3] [4] [5] [6]
  CLCS76eN 20x20  2.3   138   6.8   [1] [2] [3] [4] [5] [6] [8] [9] [10]
  CLPS66e 20x20  2.1   126   5.6   [1] [2] [3] [4] [5] [6]
  CLPS66eN 20x20  2.1   126   5.6   [1] [2] [3] [4] [5] [6] [8] [9] [10]
  CLPS76e 20x20  2.3   138   6.8   [1] [2] [3] [4] [5] [6]
  CLPS76eN 20x20  2.3   138   6.8   [1] [2] [3] [4] [5] [6] [8] [9] [10]
 
[1] Final rinse must contain 50 ppm minimum available chlorine.
[2] Unit available with a corner unloader.
[3] CLe Series dishwashing machines are also used when incorporating the "Fast Rack" or
    "FRC" transport system.  This system may incorporate one or more CLe Series dishwshing
    machine(s), fully complying with NSF Standard 2.  Model numbers would then become FRCL
    models rather than CLe models and would indicate the total length of the dishwashing
    section(s).
[4] Unit also accepted when operated as a chemical sanitizing dishwasher provided with a
    chemical sanitizing pump which is Listed under NSF Standard 29; "Low Temp" must be
    displayed on the control panel when the machine is first powered up.  Minimum wash and
    rinse temperature is 130°F.  Minimum final rinse temperature is 120°F.
[5] May be provided with wash chamber 6 inches higher than standard height 24 inches.
[6] May be provided with a blower/dryer unit option.
[8] Machine also available with “ER” denoting Drain Water Energy Recovery.
[9] Machine also available with “ADV” denoting Automatic Soil Removal.
[10] Machine rated for Pot and Pan washing. Conveyor speed and water consumption shown is the
     same for both regular running mode and Pot and Pan mode except that while in Pot and Pan
     mode, the conveyor will “dwell” 2 times for a specified amount of time (30 second
     minimum each dwell). During this dwell, the rinse is turned off until 2 seconds before
     the conveyor indexes. In Pot and Pan mode an average of 43 racks per hour can be run.

Single Tank Rack Conveyor, Hot Water Sanitizing
  CL44e 20x20  2.1   126   5.6   [2] [3] [5] [6] [7]
  CL44eN 20x20  2.1   126   5.6   [2] [3] [5] [6] [7] [8] [9] [10]
  CL44eNVL 20x20  2.1   126   5.6   [3] [10]
  CL54e 20x20  2.3   138   6.8   [2] [3] [5] [6] [7]
  CL54eN 20x20  2.3   138   6.8   [2] [3] [5] [6] [7] [8] [10]
  CLCS66e 20x20  2.1   126   5.6   [2] [3] [5] [6] [7]
  CLCS66eN 20x20  2.1   126   5.6   [2] [3] [5] [6] [7] [8] [9] [10]
  CLCS76e 20x20  2.3   138   6.8   [2] [3] [5] [6] [7]
  CLCS76eN 20x20  2.3   138   6.8   [2] [3] [5] [6] [7] [8] [9] [10]
  CLPS66e 20x20  2.1   126   5.6   [2] [3] [5] [6] [7]
  CLPS66eN 20x20  2.1   126   5.6   [2] [3] [5] [6] [7] [8] [9] [10]
  CLPS66eNVL 20x20  2.1   126   5.6   [3] [10]
  CLPS76e 20x20  2.3   138   6.8   [2] [3] [5] [6] [7]
  CLPS76eN 20x20  2.3   138   6.8   [2] [3] [5] [6] [7] [8] [9] [10]
 
[2] Unit available with a corner unloader.
[3] CLe Series dishwashing machines are also used when incorporating the "Fast Rack" or
    "FRC" transport system.  This system may incorporate one or more CLe Series dishwshing
    machine(s), fully complying with NSF Standard 2.  Model numbers would then become FRCL
    models rather than CLe models and would indicate the total length of the dishwashing
    section(s).
[5] May be provided with wash chamber 6 inches higher than standard height 24 inches.
[6] May be provided with a blower/dryer unit option.
[7] May have suffix "R" indicating energy recovery unit option.
[8] Machine also available with “ER” denoting Drain Water Energy Recovery.
[9] Machine also available with “ADV” denoting Automatic Soil Removal.
[10] Machine rated for Pot and Pan washing. Conveyor speed and water consumption shown is the
     same for both regular running mode and Pot and Pan mode except that while in Pot and Pan
     mode, the conveyor will “dwell” 2 times for a specified amount of time (30 second
     minimum each dwell). During this dwell, the rinse is turned off until 2 seconds before
     the conveyor indexes. In Pot and Pan mode an average of 43 racks per hour can be run.


GLASSWASHING MACHINES

Single Temperature, Single Cup Hot Water Sanitizing Glasswasher[1]
  SCL
  SCW
 
[1] Post Rinse “ON” (5 second sani rinse, 5 second post sani rinse).


Facility : Offenburg, Germany


GLASSWASHING MACHINES

Single Temperature, Single Cup Hot Water Sanitizing Glasswasher[1]
  SCL
  SCW
 
[1] Post Rinse “ON” (5 second sani rinse, 5 second post sani rinse).


STATIONARY RACK DISHWASHING MACHINES
      Final Rinse    
      (20 psi) Operating Time  
  Model Rack Size Flow Usage (seconds) Footnotes
  Number Width gpm gph Wash Rinse Dwell  

Single Tank, Hot Water Sanitizing[1] [2]
  AMTL 20x20  N/A    34.6   35   11   14   [3]
  AMTL 20x20  N/A    37.5   35   11   14   [4] [5]
  AMTL 20x20  N/A    45.9   35   11   14   [5] [6]
 
[1] Unit consists of two levels.  Upper level washes one rack of dishes for every cycle.
    Lower level is front load and may a) remain off, b) wash one rack of dishes for each
    cycle or c) wash one rack of dishes every 3 cycles.
[2] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
    Washing Machine. Please reference this model's Listing under Stationary Rack Pot, Pan
    and Utensil Washing Machines for this model's specifications for that mode of operation.
[3] When washing one rack every cycle in the upper section and no racks in the lower section.
[4] When washing one rack every cycle in the upper section and one rack every three cycles
    in the lower section.
[5] The lower section rinse time is 5.5 seconds and the dwell time is 19.5 seconds.
[6] When washing one rack every cycle in the upper section and one rack every cycle in the
    lower section. (Two racks washed every cycle).


STATIONARY RACK POT, PAN, AND UTENSIL WASHING MACHINES
      Final Rinse    
      (20 psi) Operating Time  
  Model Rack Size Flow Usage (seconds) Footnotes
  Number Width gpm gph Wash Rinse Dwell  

Single Tank, Hot Water Sanitizing[1] [2]
  AMTL 20x20  N/A   15.1   120   11   14   [3]
  AMTL 20x20  N/A   17   120   11   14   [4] [5]
  AMTL 20x20  N/A   24.8   120   11   14   [5] [6]
 
[1] Unit consists of two levels.  Upper level washes one rack of pots, pans, and utensils
    for every cycle. Lower level is front load and may a) remain off, b) wash one rack of
    dishes for each cycle or c) wash one rack of dishes every 3 cycles. The lower rack is
    not certified for washing Pots, Pans, & Utensils.
[2] This unit has been tested and Certified as a combination Dishwashing/Pot, Pan & Utensil
    Washing Machine. Please reference this model's Listing under Dishwashing Machines for
    this model's specifications for that mode of operation.
[3] When washing one rack every cycle in the upper section and no racks in the lower section.
[4] When washing one rack every cycle in the upper section and one rack every three cycles
    in the lower section.
[5] The lower section rinse time is 5.5 seconds and the dwell time is 19.5 seconds.
[6] When washing one rack every cycle in the upper section and one rack every cycle in the
    lower section. (Two racks washed every cycle).