NSF Product and Service Listings
These NSF Official Listings are current as of Tuesday, February 10, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/food/Listings.asp?Standard=007&Company=38210&
NSF/ANSI 7
Commercial Refrigerators and Storage Freezers
Commercial Refrigerators and Storage Freezers
| Bally Refrigerated Boxes, Inc. | |
| 135 Little Nine Drive | |
| Morehead City, NC 28557 | |
| United States | |
| 800-242-2559 | |
| 252-240-2829 |
Facility : # 1 Ontario, Canada
|
COMPONENTS: |
|
|
Extended Profile Unit Cooler [7] |
|
| BEP(2)(3)(4)(5)(6)(7)[1] | |
[1] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-135 x
1000
(3) Evap temperature range: H, L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S2, S4, S5, T3, T4, or T5
(6) Design version: engineering revision
(7) Optional suffix for internal usage
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
|
Low Profile Unit Cooler [7] |
|
| BLP(1)(2)(3)(4)(5)(6)(7)[2] | |
| BPLP(1)(2)(3)(4)(5)(6)(7)(8)[3] | |
[2] (1) (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
1000
(3) Evaporator temperature range: L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7
(6) Design version: engineering revision
(7) Optional suffix, does not affect design
[3] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
1000
(3) Evaporator temperature range: L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7
(6) Design version: engineering revision
(7) Optional suffix for internal usage
(8) Optional suffix, does not affect design
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
|
Low Velocity Walk-in Unit Cooler [7] |
|
| BLV (1)(2)(3)(4)(5) Series[5] [6] | |
| BLV060[5] [6] | |
| BLV090[5] [6] | |
| BLV120[5] [6] | |
| BLV150[5] [6] | |
| BLV180[5] [6] | |
| BLV220[5] [6] | |
| BLV270[5] [6] | |
| BLV300[5] [6] | |
| BLV340[5] [6] | |
| BLV370[5] [6] | |
| BTM(1)(2)(3)(4)(5)(6) Series[4] | |
[4] (1) 3 digit number from 009-531, indicating nominal capacity and number of Fans
(2) Evap temperature range: L, M, V, or W
(3) Defrost type: A, E, G, H, R, or T
(4) Unit electrical designation: S2, S4, T3,T4
(5) Design version
(6) Optional suffix, does not affect design
[5] BLV units Certified with the following suffix designations
(1) Fluid designations: W (if applicable) - water/glycol
(2) Defrost type: AD, ED, HE, RE or TE
(3) Voltage: S1 , S2, S5 or S6
(4) Design version
(5) Optional suffix, does not affect design
[6] BLV models may contain a four digit numeric suffix to indicate customer required
options
These options may not include changes to the unit exterior or mounting.
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
|
Medium Profile Unit Cooler [7] |
|
| BMP(1)(2)(3)(4)(5)(6)(7)[1] | |
[1] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-135 x
1000
(3) Evap temperature range: H, L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S2, S4, S5, T3, T4, or T5
(6) Design version: engineering revision
(7) Optional suffix for internal usage
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
Facility : Kilgore, TX
|
COMPONENTS: |
|
|
Low Profile Unit Cooler [7] |
|
| BLP(1)(2)(3)(4)(5)(6)(7)[1] | |
| BPLP(1)(2)(3)(4)(5)(6)(7)(8)[2] | |
[1] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x 1000
(3) Evaporator temperature range: L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7
(6) Design version: engineering revision
(7) Optional suffix, does not affect design
[2] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
1000
(3) Evaporator temperature range: L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7
(6) Design version: engineering revision
(7) Optional suffix for internal usage
(8) Optional suffix, does not affect design
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field.
|
|
|
Low Velocity Walk-In Unit Cooler [7] |
|
| BLV (1)(2)(3)(4) Series[4] [5] | |
| BLV060[4] [5] | |
| BLV120[4] [5] | |
| BLV150[4] [5] | |
| BLV180[4] [5] | |
| BLV220[4] [5] | |
| BLV270[4] [5] | |
| BLV300[4] [5] | |
| BLV340[4] [5] | |
| BLV370[4] [5] | |
| BTM(1)(2)(3)(4)(5)(6) Series[3] | |
[3] (1) 3 digit number from 009-531, indicating nominal capacity and number of Fans
(2) Evap temperature range: L, M, V, or W
(3) Defrost type: A, E, G, H, R, or T
(4) Unit electrical designation: S2, S4, T3,T4
(5) Design version
(6) Optional suffix, does not affect design
[4] BLV units Certified with the following suffix designations
(1) Fluid designations: W (if applicable) - water/glycol
(2) Defrost type: AD, ED, HE, RE or TE
(3) Voltage: S1 , S2, S5 or S6
(4) Design version
(5) Optional suffix, does not affect design
[5] BLV models may contain a four digit numeric suffix to indicate customer required
options. These options may not include changes to the unit exterior or mounting.
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field.
|
|
|
Medium Profile Unit Cooler [7] |
|
| BMP(1)(2)(3)(4)(5)(6)(7)[6] | |
[6] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x 1000
(3) Evap temperature range: L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S2, S4, S5, T3, T4, or T5
(6) Design version: engineering revision
(7) Optional suffix for internal usage
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field.
|
|
Number of matching Manufacturers is 1
Number of matching Products is 30
Processing time was 0 seconds