NSF/ANSI 7
Commercial Refrigerators and Storage Freezers



 
Bally Refrigerated Boxes, Inc. 
135 Little Nine Drive
Morehead City, NC 28557 
United States 
800-242-2559 
252-240-2829

Facility : # 1 Ontario, Canada


COMPONENTS:

Extended Profile Unit Cooler [7]
  BEP(2)(3)(4)(5)(6)(7)[1]
 
[1] (1) Number of fans	
    (2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-135 x
    1000	
    (3) Evap temperature range: H, L, M, V, or W	
    (4) Defrost type: A, E, G, H, R, or T	
    (5) Unit electrical designation: S2, S4, S5, T3, T4, or T5	
    (6) Design version: engineering revision	
    (7) Optional suffix for internal usage
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
    installed in the field

Low Profile Unit Cooler [7]
  BLP(1)(2)(3)(4)(5)(6)(7)[2]
  BPLP(1)(2)(3)(4)(5)(6)(7)(8)[3]
 
[2] (1) (1) Number of fans	
    (2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
    1000	
    (3) Evaporator temperature range: L, M, V, or W	
    (4) Defrost type: A, E, G, H, R, or T	
    (5)  Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7	
    (6) Design version: engineering revision
    (7) Optional suffix, does not affect design
[3] (1) Number of fans	
    (2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
    1000	
    (3) Evaporator temperature range: L, M, V, or W	
    (4) Defrost type: A, E, G, H, R, or T	
    (5)  Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7	
    (6) Design version: engineering revision	
    (7) Optional suffix for internal usage
    (8) Optional suffix, does not affect design
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
    installed in the field

Low Velocity Walk-in Unit Cooler [7]
  BLV (1)(2)(3)(4)(5) Series[5] [6]
  BLV060[5] [6]
  BLV090[5] [6]
  BLV120[5] [6]
  BLV150[5] [6]
  BLV180[5] [6]
  BLV220[5] [6]
  BLV270[5] [6]
  BLV300[5] [6]
  BLV340[5] [6]
  BLV370[5] [6]
  BTM(1)(2)(3)(4)(5)(6) Series[4]
 
[4] (1) 3 digit number from 009-531, indicating nominal capacity and number of Fans	
    (2) Evap temperature range: L, M, V, or W	
    (3) Defrost type: A, E, G, H, R, or T	
    (4) Unit electrical designation: S2, S4, T3,T4	
    (5) Design version	
    (6) Optional suffix, does not affect design
[5] BLV units Certified with the following suffix designations	
    (1) Fluid designations: W (if applicable) - water/glycol	
    (2) Defrost type: AD, ED, HE,  RE or TE	
    (3) Voltage: S1 , S2,  S5 or S6	
    (4) Design version
    (5) Optional suffix, does not affect design
[6] BLV models may contain a four digit numeric suffix to indicate customer required
    options	
    These options may not include changes to the unit exterior or mounting.
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
    installed in the field

Medium Profile Unit Cooler [7]
  BMP(1)(2)(3)(4)(5)(6)(7)[1]
 
[1] (1) Number of fans	
    (2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-135 x
    1000	
    (3) Evap temperature range: H, L, M, V, or W	
    (4) Defrost type: A, E, G, H, R, or T	
    (5) Unit electrical designation: S2, S4, S5, T3, T4, or T5	
    (6) Design version: engineering revision	
    (7) Optional suffix for internal usage
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
    installed in the field


Facility : Kilgore, TX


COMPONENTS:

Low Profile Unit Cooler [7]
  BLP(1)(2)(3)(4)(5)(6)(7)[1]
  BPLP(1)(2)(3)(4)(5)(6)(7)(8)[2]
 
[1] (1) Number of fans
    (2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x 1000
    (3) Evaporator temperature range: L, M, V, or W
    (4) Defrost type: A, E, G, H, R, or T
    (5)  Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7
    (6) Design version: engineering revision
    (7) Optional suffix, does not affect design
[2] (1) Number of fans	
    (2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
    1000	
    (3) Evaporator temperature range: L, M, V, or W	
    (4) Defrost type: A, E, G, H, R, or T	
    (5)  Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7	
    (6) Design version: engineering revision
    (7) Optional suffix for internal usage
    (8) Optional suffix, does not affect design
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
    installed in the field.

Low Velocity Walk-In Unit Cooler [7]
  BLV (1)(2)(3)(4) Series[4] [5]
  BLV060[4] [5]
  BLV120[4] [5]
  BLV150[4] [5]
  BLV180[4] [5]
  BLV220[4] [5]
  BLV270[4] [5]
  BLV300[4] [5]
  BLV340[4] [5]
  BLV370[4] [5]
  BTM(1)(2)(3)(4)(5)(6) Series[3]
 
[3] (1) 3 digit number from 009-531, indicating nominal capacity and number of Fans
    (2) Evap temperature range: L, M, V, or W
    (3) Defrost type: A, E, G, H, R, or T
    (4) Unit electrical designation: S2, S4, T3,T4
    (5) Design version
    (6) Optional suffix, does not affect design
[4] BLV units Certified with the following suffix designations
    (1) Fluid designations: W (if applicable) - water/glycol
    (2) Defrost type: AD, ED, HE,  RE or TE
    (3) Voltage: S1 , S2,  S5 or S6
    (4) Design version
    (5) Optional suffix, does not affect design
[5] BLV models may contain a four digit numeric suffix to indicate customer required
    options. These options may not include changes to the unit exterior or mounting.	
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
    installed in the field.

Medium Profile Unit Cooler [7]
  BMP(1)(2)(3)(4)(5)(6)(7)[6]
 
[6] (1) Number of fans
    (2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x 1000
    (3) Evap temperature range: L, M, V, or W
    (4) Defrost type: A, E, G, H, R, or T
    (5) Unit electrical designation: S2, S4, S5, T3, T4, or T5
    (6) Design version: engineering revision
    (7) Optional suffix for internal usage
[7] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
    installed in the field.