NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, November 6, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/food/Listings.asp?Standard=007&Company=38210&
NSF/ANSI 7
Commercial Refrigerators and Storage Freezers
Commercial Refrigerators and Storage Freezers
| Bally Refrigerated Boxes, Inc. | |
| 135 Little Nine Drive | |
| Morehead City, NC 28557 | |
| United States | |
| 800-242-2559 | |
| 252-240-2829 |
Facility : # 1 Ontario, Canada
|
COMPONENTS: |
|
|
Air Defrost Low Profile Walk-In Unit Cooler [8] |
|
| BLT(1)(2)(3)(4)(5)(6) Series[1] | |
[1] (1) 3 digit number from 009-531, indicating nominal capacity
(2) Evaporator temperature range: L or M
(3) Defrost type: A, E, G, H, R, or T
(4) Unit electrical designation - S1, S2
(5) Design version
(6) Optional suffix, does not affect design
[8] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
|
Extended Profile Unit Cooler [8] |
|
| BEP(2)(3)(4)(5)(6)(7)[2] | |
[2] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-135 x
1000
(3) Evap temperature range: H, L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S2, S4, S5, T3, T4, or T5
(6) Design version: engineering revision
(7) Optional suffix for internal usage
[8] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
|
Low Profile Unit Cooler [8] |
|
| BLP(1)(2)(3)(4)(5)(6)(7)[3] | |
| BPLP(1)(2)(3)(4)(5)(6)(7)(8)[4] | |
[3] (1) (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
1000
(3) Evaporator temperature range: L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7
(6) Design version: engineering revision
[4] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
1000
(3) Evaporator temperature range: L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7
(6) Design version: engineering revision
(7) Optional suffix for internal usage
[8] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
|
Low Velocity Walk-in Unit Cooler [8] |
|
| BLV060[6] [7] | |
| BLV090[6] [7] | |
| BLV120[6] [7] | |
| BLV150[6] [7] | |
| BLV180[6] [7] | |
| BLV220[6] [7] | |
| BLV270[6] [7] | |
| BLV300[6] [7] | |
| BLV340[6] [7] | |
| BLV370[6] [7] | |
| BTM(1)(2)(3)(4)(5)(6) Series[5] | |
[5] (1) 3 digit number from 009-531, indicating nominal capacity and number of Fans
(2) Evap temperature range: L, M, V, or W
(3) Defrost type: A, E, G, H, R, or T
(4) Unit electrical designation: S2, S4, T3,T4
(5) Design version
(6) Optional suffix, does not affect design
[6] BLV units Certified with the following suffix designations
(1) Fluid designations: W (if applicable) - water/glycol
(2) Defrost type: AD, ED, HE, RE or TE
(3) Voltage: S1 , S2, S5 or S6
(4) Design version
[7] BLV models may contain a four digit numeric suffix to indicate customer required
options
These options may not include changes to the unit exterior or mounting.
[8] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
|
Medium Profile Unit Cooler [8] |
|
| BMP(1)(2)(3)(4)(5)(6)(7)[2] | |
[2] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-135 x
1000
(3) Evap temperature range: H, L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S2, S4, S5, T3, T4, or T5
(6) Design version: engineering revision
(7) Optional suffix for internal usage
[8] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
Facility : Longview, TX
|
COMPONENTS: |
|
|
Air Defrost Low Profile Walk-In Unit Cooler [8] |
|
| BTL(1)(2)(3)(4)(5)(6) Series[1] | |
[1] (1) 3 digit number from 009-531, indicating nominal capacity
(2) Evaporator temperature range: L or M
(3) Defrost type: A, E, G, H, R, or T
(4) Unit electrical designation - S1, S2
(5) Design version
(6) Optional suffix, does not affect design
[8] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
|
Low Profile Unit Cooler [8] |
|
| BLP(1)(2)(3)(4)(5)(6)(7)[2] | |
| BPLP(1)(2)(3)(4)(5)(6)(7)(8)[3] | |
[2] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
1000
(3) Evaporator temperature range: L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7
(6) Design version: engineering revision
[3] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
1000
(3) Evaporator temperature range: L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S1, S2, S4, S5, S6, T3, T4, T5, or T7
(6) Design version: engineering revision
(7) Optional suffix for internal usage
[8] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
|
Low Velocity Walk-In Unit Cooler [8] |
|
| BLV (1)(2)(3)(4) Series[5] [6] | |
| BLV060[5] [6] | |
| BLV120[5] [6] | |
| BLV150[5] [6] | |
| BLV180[5] [6] | |
| BLV220[5] [6] | |
| BLV270[5] [6] | |
| BLV300[5] [6] | |
| BLV340[5] [6] | |
| BLV370[5] [6] | |
| BTM(1)(2)(3)(4)(5)(6) Series[4] | |
[4] (1) 3 digit number from 009-531, indicating nominal capacity and number of Fans
(2) Evap temperature range: L, M, V, or W
(3) Defrost type: A, E, G, H, R, or T
(4) Unit electrical designation: S2, S4, T3,T4
(5) Design version
(6) Optional suffix, does not affect design
[5] BLV units Certified with the following suffix designations
(1) Fluid designations: W (if applicable) - water/glycol
(2) Defrost type: AD, ED, HE, RE or TE
(3) Voltage: S1 , S2, S5 or S6
(4) Design version
[6] BLV models may contain a four digit numeric suffix to indicate customer required
options
These options may not include changes to the unit exterior or mounting.
[8] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
|
Medium Profile Unit Cooler [8] |
|
| BMP(1)(2)(3)(4)(5)(6)(7)[7] | |
[7] (1) Number of fans
(2) Nominal capacity (10°F TD, 60Hz) in BTU/H = any two numeric digits from 03-99 x
1000
(3) Evap temperature range: L, M, V, or W
(4) Defrost type: A, E, G, H, R, or T
(5) Unit electrical designation: S2, S4, S5, T3, T4, or T5
(6) Design version: engineering revision
(7) Optional suffix for internal usage
[8] Models may include Drain Pan Loop Kit Note: Drain Pan Loop Kit is shipped separately and
installed in the field
|
|
Number of matching Manufacturers is 1
Number of matching Products is 31
Processing time was 0 seconds