NSF Product and Service Listings

These NSF Official Listings are current as of Saturday, May 18, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/food/Listings.asp?Company=4T680&


NSF/ANSI 169
Special Purpose Food Equipment and Devices



 
Olab SRL 
Via Enrico Mattei, 16
25030 Torbole Casaglia (BS) 
Italy 
39 0 30 215 9411
Visit this company's website

Facility : Torbole Casaglia (BS), Italy


COMPONENTS:

F-100XX AISI 316 Stainless Steel Fittings for Food Zone[1]
  F-ADAX (1)/(2)
  F-EGCXX (1)/(2)
  F-EGXX (1)/(2)
  F-ELRXX (1)/(2)
  F-ERCXX (1)/(2)
  F-RIDXX (1)/(2)
  F-TGCCXX (1)/(2)
  F-TGCXX (1)/(2)
  F-TLRXX (1)/(2)
  F-TRCCXX (1)/(2)
  F-ULRMXX (1)/(2)
  F-ULRXX (1)/(2)
  F-UMRCXX (1)/(2)
  F-UMRXX (1)/(2)
 
[1] (1) Digit(s) indicating tube diameter
    (2) Digits indicating threads F100-XX AISI 316

SERIE 400 AISI 316 Stainless Steel Fittings for Food Zone[2]
  414-(2)x(1)-K
  430-(1)x(1)-K
  441-(1)-K
  444-(1)x(1)-K
  446-(1)-K
  447-(1)x(1)-(3)-K
  448-(1)x(1)-K
  450-(1)-K
  452-(1)-K
  452/A-(1)-KI
  453-(1)-K
  456-(1)-K
  458-(1)-K
  459-(1)-K
  461-(1)-K
  462-(1)-K
  464-(1)-K
  489-(1)-K
 
[2] (1) Digit(s) indicating tube diameter
    (2) Digits indicating threads 400 AISI 316
    (3) Digits indicating length

Vibration Pumps - 22000 Series[3] [Pb]
  22000-03-120-(1)-R-(2)
  22000-04-095-(1)-R-(2)
  22000-07-100-(1)-R-(2)
  22000-15-065-(1)-R-(2)
  22000-20-042-(1)-R-(2)
  22001-03-120-(1)-R-(2)
  22001-04-095-(1)-R-(2)
  22001-07-100-(1)-R-(2)
  22001-15-065-(1)-R-(2)
  22001-20-042-(1)-R-(2)
 
[3] (1) Digits defining type of coil
    (2) Digit defining special features (e.g: Customized label, external joints)
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

Valves - Brass Series [Pb]
  08201L(1)-(2)-(3)(4)-(5)-(6)[8]
  0825(1)L(2)-(3)(4)-(5)-(6)-(7)-(8)[9]
  08600L(1)-(2)-(3)(4)-(5)-(6)[10]
  08800L(1)-(2)-(3)(4)-(5)-(6)[10]
  0980(1)L-(2)(3)-(4)-(5)-(6)(7)[11]
  0985(1)L-(2)(3)-(4)-(5)-(6)(7)[12]
  180(1)(2)L-(3)-(4)-(5)-(6)-(7)[13]
  180(1)(2)L-(3)-(4)-LP-(6)-(7)[13] [17]
  185(1)(2)L-(3)-(4)-(5)-(6)-(7)[14]
  185(1)(2)L-(3)-(4)-LP-(6)-(7)[14] [17]
 
[8] (1) 2 characters or numbers, for body type or threads type
    (2) 2 numbers, for internal diameter DN
    (3) 1 possible character or number, for the positioning of the coil
    (4) 1 character or number, for type of coil
    (5) Up to three charatcer for brass treatment
    (6) Up to 2 characters or numbers for customization
[9] (1) 1 character or number, for third way geometry
    (2) 2 characters or numbers, for body type or threads type
    (3) 1 character or number, for spring and third way type
    (4) 2 numbers, for internal diameter DN
    (5) 1 possible character or number, for the positioning of the coil
    (6) 1 character or number, for type of coil
    (7) Up to three characters for brass treatment
    (8) Up to 2 characters or numbers for customization
[10] (1) 2 characters or numbers, for body type or threads type
     (2) 2 numbers, for internal diameter DN
     (3) 1 possible character or number, for the positioning of the coil
     (4) 1 character or number, for type of coil
     (5) Up to three charatcers for brass treatment
     (6) Up to 2 characters or numbers for customization
     
[11] (1) One number for brass treatment
     (2) One character or number for third way diameter, spring and filter
     (3) 2 numbers, for internal diameter DN
     (4) 1 character or number, for gasket material
     (5) 1 character or number, for type of coil
     (6) 1 possible character or number, for the positioning of the coil
     (7) Up to 2 characters or numbers for customization
[12] (1) One number for brass treatment
     (2) One character or number, for spring and filter
     (3) 2 numbers, for internal diameter DN
     (4) 1 character or number, for gasket material
     (5) 1 character or number, for type of coil
     (6) 1 possible character or number, for the positioning of the coil
     (7) Up to 2 characters or numbers for customization
[13] (1) 1 character or number, for presence or absence of coil and connector
     (2) 1 character or number, for type of closure (normally or slow closure)
     (3) 2 characters or numbers, for threads and treatment
     (4) 3 numbers, for internal diameter DN
     (5) Up to 2 characters or numbers, for gasket material, except LP
     (6) Up to 2 possible characters or numbers, for the type of the coil
     (7) Up to 2 characters or numbers for customization
[14] (1) 1 character or number, for presence of coil and connector
     (2) 1 character or number, for type of closure (normally or slow closure)
     (3) 2 characters or numbers, for threads and treatment
     (4) 3 numbers, for internal diameter DN
     (5) Up to 2 characters or numbers, for gasket material, except LP
     (6) Up to 2 characters or numbers, for type of coil
     (7) Up to 2 characters or numbers, for customization
[17] Only acceptable for use in contact with non-carbonated potable water
     with a maximum contact temperature of 82°C (180°F).
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

Valves - Stainless Steel Series [Pb]
  08201K(1)-(2)-(3)-(4)(5)-(6)[4]
  0825(1)K(2)-(3)(4)-(5)-(6)(7)-(8)[5]
  18(1)(2)(3)K-(4)-(5)-(6)-(7)-(8)[6]
  18(1)(2)(3)K-(4)-(5)-LP-(7)-(8)[6] [17]
  185(1)(2)K-(3)-(4)-(5)-(6)-(7)[7]
  185(1)(2)K-(3)-(4)-LP-(6)-(7)[7] [17]
 
[4] (1) 2 characters or numbers, for body type or threads type
    (2) 2 numbers, for internal diameter DN
    (3) Up to 3 characters or numbers, for gasket material
    (4) 1 possible character or number, for the positioning of the coil
    (5) 1 character or number, for type of coil
    (6) Up to 2 possible characters or numbers, for customization
[5] (1) 1 character or number, for third way geometry
    (2) 2 characters or numbers, for body type or threads type
    (3) 1 character or number, for spring and third way type
    (4) 2 numbers, for internal diameter DN
    (5) Up to 3 characters or numbers, for gasket material
    (6) 1 possible character or number, for the positioning of the coil
    (7) 1 character or number, for type of coil
    (8) Up to 2 possible characters or numbers, for customization
[6] (1) 1 character or number, for manual opening
    (2) 1 character or number, for presence of coil and connector
    (3) 1 character or number, for type of closure (normally or slow closure)
    (4) 2 characters or numbers, for threads
    (5) 3 numbers for internal diameter, DN
    (6) Up to 2 characters or numbers, for gasket material, except LP
    (7) Up to 2 possible characters or numbers, for type of coil
    (8) Up to 2 possible characters or numbers, for customization
[7] (1) 1 character or number, for presence of coil and connector
    (2) 1 character or number, for type of closure (normally or slow closure)
    (3) 2 characters or numbers, for threads
    (4) 3 numbers for internal diameter, DN
    (5) Up to 2 characters or numbers, for gasket material, except LP
    (6) Up to 2 possible characters or numbers, for type of coil
    (7) Up to 2 possible characters or numbers, for customization
[17] Only acceptable for use in contact with non-carbonated potable water
     with a maximum contact temperature of 82°C (180°F).
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.

FCL 100 Series [Pb]
  FCL-(1)(2)-0(3)(4)-(5)[16]
  FCL-(1)-B(2)-01(3)-(4)[15]
 
[15] (1) Up to 4 characters or numbers for type of body
     (2) 2 characters or numbers for tubing dimension
     (3) 1 character or number for thread
     (4) Up to 3 characters or numbers for brass treatment
[16] (1) 3 characters or numbers for type of accessory
     (2) 2 characters or numbers for tubing dimension
     (3) 1 character or number for FKM seal
     (4) One character or number for thread
     (5) Up to 3 characters or numbers for brass treatment
[Pb] Product also evaluated and determined to possess weighted average lead content of
     <=0.25% and complies with lead content requirements for “lead free” plumbing as defined
     by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking
     Water Act.


Number of matching Manufacturers is 1
Number of matching Products is 60
Processing time was 0 seconds