NSF Product and Service Listings

These NSF Official Listings are current as of Thursday, January 15, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/food/Listings.asp?Standard=002&Company=C0044812&


NSF/ANSI 2
Food Equipment



 
Visioneering Corp / CertoLUX 
35 Oak Street
North York, ON M9N 1A1 
Canada 
416-245-7991
Visit this company's website

Facility : North York, Ontario, Canada


Light Fixtures for Food Zone, Splash Zone and Non-Food Zone Applications[1]
  CR(1)(2)(3)(4)/(5)(6)(7)(8)(9)(10)-(11) - X5[2]
  CRU(1)(2)-(3)/(4)LED(5)(6)(7)(8)-(9)-(10) - X5[3]
  LRT(1)-C29-(2)-LED(3)(4)(5)(6)-(7) - X5[4]
  MSU(1)(2)-(3)/(4)LED(5)(6)(7)(8)-(9)-(10) - X5[5]
  SAF(1)(2)-(3)(4)-(5)(6)(7)(8)-(9) - X5[6]
 
[1] Hyphens may be inserted between fields to help with readability.
[2] (1)  Fixture Type and/or Door Style [OPTIONAL]
         C, F, FP, FR, FX, G, IF, IFP, IFR, IG, IGP, IGR, IS, ISP, ISR,
         S, SP, SR, TD
    (2)  Fixture Model [OPTIONAL]
         xxxx (where xxxx is a 4 digit model number)
    (3)  Fixture nominal size
         1 X 1 (Width X Length format in feet)
         1 X 2 (Width X Length format in feet)
         1 X 3 (Width X Length format in feet)
         1 X 4 (Width X Length format in feet)
         2 X 2 (Width X Length format in feet)
         2 X 4 (Width X Length format in feet)
         12 (Length only format in inches)
         24 (Length only format in inches)
         36 (Length only format in inches)
         48 (Length only format in inches)
         72 (Length only format in inches)
         96 (Length only format in inches)
    (4)  Door Gauge [If Applicable]  
         Alpha numeric digit indicating metal gauge  
         /  Not shown if (4) & (5) are not used.    
    (5)  Housing Gauge [If Applicable]
         Alpha numeric digit indicating metal gauge
    (6)  Digit indicating number of lamps -OR- LED.
    (7)  Alpha/numeric digits indicating lamp type -OR- Digit indicating Colour Rendering
         Index (CRI).
    (8)  Digits indicating lamp watts  -OR- Alpha/numeric digits indicating Colour
         Temperature.
    (9)  Alpha/numeric digits indicating ballast type -OR- Alpha/numeric digits 
         indicating lumen output.
    (10) Alpha/numeric digits indicating voltage
    (11) 1 or more optional suffixes may appear
         Bxx (where xx are digits indicating ballast or driver option)
         Cxx (where xx are digits indicating construction code)
         F35 & F47 (Code indicating NSF compliant Gloss White paint -- may or
         may not appear, but this is only allowed paint for exposed parts
         when Code X5 is used)
         K0
         Mxx (where xx are digits indicating mounting options)
         Pxx (where xx are 2 digits indicating lens thickness and material)
         T5
         T6
         Rxx (where xxx are digits indicating reflector option)
         VFx (where x is digit indicating reflector option)
         Vxx (where xx are digits indicating wiring option)
         X1
         X3
         X4
         X7
         X8
         Z1(xxx) (Where xxx are 3 digits indicating light colour temperature)
[3] (1)  Fixture type: i,o
    (2)  Fixture nominal size -
         [Digits denoting size in format Width X Length (in feet, inches, or in
         millimeters.)]
    (3)  Door Gauge - Alpha numeric digit indicating metal gauge
    (4)  Housing Gauge - Alpha numeric digit indicating metal gauge
         LED
    (5)  Digit indiating Colour Rendering Index (CRI)
    (6)  Alpha/numeric digits indicating Colour Temperature
    (7)  Alpha/numeric digits indicating lumen output. Alternatively,
         this could be 2 Lumen code separated by a slash (/) for white
         and single colour lumen outputs
    (8)  Alpha/numeric digits indicating voltage
    (9)  Alpha-numeric code indicating lens thickness and material
         NOTE: the room side lens MUST be NSF compliant.
    (10) 1 or more optional suffixes may appear [OPTIONAL)
         Bxx (where xx are digits indicating driver option)
         Cxx (where xx are digits indicating construction code)
         F35 or F47 (Code indicating NSF compliant Gloss White paint --
         may or may not appear, but these are the only allowed paints for
         exposed parts)
         Kxx (where xx are digits indicating packaging options)
         Mxx (where xx are digits indicating mounting options)
         Txx (where xx are digits indicating fusing options)
         Rxx (where xxx are digits indicating reflector option)
         VFx (where x is digit indicating reflector option)
         Vxx (where xx are digits indicating wiring option)
         Xxx (where xx are digits indicating certification)
[4] (1) Fixture Type A, B, C, F, G, H, J, P, Z (letter code designation for different
        internal lensing option)    
    (2) Fixture nominal size
        1 X 4 (Width X Length format in feet)
        2 X 2 (Width X Length format in feet)
        2 X 4 (Width X Length format in feet)
    (3) Digit indicating Color Rendering Index (CRI).    
    (4) Alpha/numeric digits indicating Color Temperature.    
    (5) Alpha/numeric digits indicating lumen output.    
    (6) Alpha/numeric digits indicating input voltage    
    (7) 1 or more optional suffixes may appear [OPTIONAL, except X5 is mandatory for NSF]
        Bxx (where xx are digits indicating driver option)
        Cxx (where xx are digits indicating construction codes)
        F35 or F47 (Code indicating NSF compliant Gloss White paint -- may or
        may not appear, but these are the only allowed paints for exposed
        parts when Code X5 is used))
        Kxx (where xx are digits indicating packaging option)
        Pxx (where xx are 2 digits indicating lens thickness and material)
        Rxx (where xxx are digits indicating reflector option)
        Vxx (where xx are digits indicating wiring option)
        Xxx (where xx are digits indicating other approval options)
[5] (1)  Fixture type: i,o
    (2)  Fixture nominal size
         [Digits denoting size in format Width X Length (in feet, inches or
         in millimeters)]
    (3)  Door Gauge - Alpha numeric digit indicating metal gauge
    (4)  Housing Gauge, Alpha numeric digit indicating metal gauge
    (5)  Digit indicating Colour Rendering Index (CRI)
    (6)  Alpha/numeric digits indicating Colour Temperature.
    (7)  Alpha/numeric digits indicating lumen output. Alternatively,
         this could be 2 Lumen code separated by a slash (/) for white
         and single colour lumen outputs.
    (8)  Alpha/numeric digits indicating voltage
    (9)  Alpha-numeric code indicating lens thickness and material
         NOTE: The room side lens MUST be NSF compliant.
    (10) 1 or more optional suffixes may appear [OPTIONAL)
         Bxx (where xx are digits indicating driver option)
         Cxx (where xx are digits indicating construction code)
         F35 or F47 (Code indicating NSF compliant Gloss White paint -- may
         or may not appear, but these are the only allowed paints for
         exposed parts)
         Kxx (where xx are digits indicating packaging options)
         Mxx (where xx are digits indicating mounting options)
         Txx (where xx are digits indicating fusing options)
         Rxx (where xxx are digits indicating reflector option)
         VFx (where x is digit indicating reflector option)
         Vxx (where xx are digits indicating wiring option)
         Xxx (where xx are digits indicating certification)
[6] (1) Fixture type [OPTIONAL]
        G, GP, GR, P, R, X
    (2) Fixture model Optional
        xxxx (where xxxx is a 4 digit model number)
    (3) Fixture Nominal Size
        1x1 (Width X Length format in feet)
        1x2 (Width X Length format in feet)
        1X3 (Width X Length format in feet)
        1X4 (Width X Length format in feet)
        2X2 (Width X Length format in feet)
        2X4 (Width X Length format in feet) 
    (4) Digit indicating number of lamps –OR- LED
    (5) Alpha/numeric digits indicating lamp type -OR- Digit indicating color rendering 
        index (CRI)
    (6) Digits indicating lamp watts –OR- Alpha/numeric digits indicating Colour
        Temperature.
    (7) Alpha/numeric digits indicating ballast type -OR- Alpha/numeric digits indicating 
        lumen output.
    (8) Alpha/numeric digit indicating voltage
    (9) 1 or more optional suffixes may appear
        Bxx (where xx are digits indicating ballast or driver option)
        Cxx (where xx are digits indicating construction code)
        D3
        D9
        D10
        D17
        D18
        F35 or F47 (Code indicating NSF compliant Gloss White paint -- may or may not
        appear, but these are the only allowed paints for exposed parts when Code X5 
        is used)
        K0
        Mxx (where xx are digits indicating mounting options)
        Pxx (where xx are 2 digits indicating lens thickness and material)
        T5
        T6
        Rxx (where xxx are digits indicating reflector option)
        VFx (where x is digit indicating reflector option)
        Vxx (where xx are digits indicating wiring option)
        X1
        X3
        X4
        X7
        X8
        Z1(xxx) (Where xxx are 3 digits indication light colour

Light Fixtures for Splash Zone and Non-Food Zone Applications[1]
  BDL(1)-(2)-(3)-(4)-(5)(6)(7)(8)-(9)(10)[7]
  CR(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)-(11)[2]
  CRD(1)-(2)-(3)-(4)-(5)(6)(7)(8)-(9)(10)[7]
  CRU(1)(2)-(3)/(4)LED(5)(6)(7)(8)-(9)-(10)[3]
  LRT(1)-C29-(2)-LED(3)(4)(5)(6)-(7)[4]
  MDD(1)-(2)-(3)-(4)-(5)(6)(7)(8)-(9)(10)[7]
  MDL(1)-(2)-(3)-(4)-(5)(6)(7)(8)-(9)(10)[7]
  MSD(1)-(2)-(3)-(4)-(5)(6)(7)(8)-(9)(10)[7]
  MSU(1)(2)-(3)/(4)LED(5)(6)(7)(8)-(9)-(10)[5]
  SAF(1)(2)-(3)(4)-(5)(6)(7)(8)-(9)[6]
  VRD(1)-(2)-(3)-(4)-(5)(6)(7)(8)-(9)(10)[7]
 
[1] Hyphens may be inserted between fields to help with readability.
[2] (1)  Fixture Type and/or Door Style [OPTIONAL]
         C, F, FP, FR, FX, G, IF, IFP, IFR, IG, IGP, IGR, IS, ISP, ISR,
         S, SP, SR, TD
    (2)  Fixture Model [OPTIONAL]
         xxxx (where xxxx is a 4 digit model number)
    (3)  Fixture nominal size
         1 X 1 (Width X Length format in feet)
         1 X 2 (Width X Length format in feet)
         1 X 3 (Width X Length format in feet)
         1 X 4 (Width X Length format in feet)
         2 X 2 (Width X Length format in feet)
         2 X 4 (Width X Length format in feet)
         12 (Length only format in inches)
         24 (Length only format in inches)
         36 (Length only format in inches)
         48 (Length only format in inches)
         72 (Length only format in inches)
         96 (Length only format in inches)
    (4)  Door Gauge [If Applicable]  
         Alpha numeric digit indicating metal gauge  
         /  Not shown if (4) & (5) are not used.    
    (5)  Housing Gauge [If Applicable]
         Alpha numeric digit indicating metal gauge
    (6)  Digit indicating number of lamps -OR- LED.
    (7)  Alpha/numeric digits indicating lamp type -OR- Digit indicating Colour Rendering
         Index (CRI).
    (8)  Digits indicating lamp watts  -OR- Alpha/numeric digits indicating Colour
         Temperature.
    (9)  Alpha/numeric digits indicating ballast type -OR- Alpha/numeric digits 
         indicating lumen output.
    (10) Alpha/numeric digits indicating voltage
    (11) 1 or more optional suffixes may appear
         Bxx (where xx are digits indicating ballast or driver option)
         Cxx (where xx are digits indicating construction code)
         F35 & F47 (Code indicating NSF compliant Gloss White paint -- may or
         may not appear, but this is only allowed paint for exposed parts
         when Code X5 is used)
         K0
         Mxx (where xx are digits indicating mounting options)
         Pxx (where xx are 2 digits indicating lens thickness and material)
         T5
         T6
         Rxx (where xxx are digits indicating reflector option)
         VFx (where x is digit indicating reflector option)
         Vxx (where xx are digits indicating wiring option)
         X1
         X3
         X4
         X7
         X8
         Z1(xxx) (Where xxx are 3 digits indicating light colour temperature)
[3] (1)  Fixture type: i,o
    (2)  Fixture nominal size -
         [Digits denoting size in format Width X Length (in feet, inches, or in
         millimeters.)]
    (3)  Door Gauge - Alpha numeric digit indicating metal gauge
    (4)  Housing Gauge - Alpha numeric digit indicating metal gauge
         LED
    (5)  Digit indiating Colour Rendering Index (CRI)
    (6)  Alpha/numeric digits indicating Colour Temperature
    (7)  Alpha/numeric digits indicating lumen output. Alternatively,
         this could be 2 Lumen code separated by a slash (/) for white
         and single colour lumen outputs
    (8)  Alpha/numeric digits indicating voltage
    (9)  Alpha-numeric code indicating lens thickness and material
         NOTE: the room side lens MUST be NSF compliant.
    (10) 1 or more optional suffixes may appear [OPTIONAL)
         Bxx (where xx are digits indicating driver option)
         Cxx (where xx are digits indicating construction code)
         F35 or F47 (Code indicating NSF compliant Gloss White paint --
         may or may not appear, but these are the only allowed paints for
         exposed parts)
         Kxx (where xx are digits indicating packaging options)
         Mxx (where xx are digits indicating mounting options)
         Txx (where xx are digits indicating fusing options)
         Rxx (where xxx are digits indicating reflector option)
         VFx (where x is digit indicating reflector option)
         Vxx (where xx are digits indicating wiring option)
         Xxx (where xx are digits indicating certification)
[4] (1) Fixture Type A, B, C, F, G, H, J, P, Z (letter code designation for different
        internal lensing option)    
    (2) Fixture nominal size
        1 X 4 (Width X Length format in feet)
        2 X 2 (Width X Length format in feet)
        2 X 4 (Width X Length format in feet)
    (3) Digit indicating Color Rendering Index (CRI).    
    (4) Alpha/numeric digits indicating Color Temperature.    
    (5) Alpha/numeric digits indicating lumen output.    
    (6) Alpha/numeric digits indicating input voltage    
    (7) 1 or more optional suffixes may appear [OPTIONAL, except X5 is mandatory for NSF]
        Bxx (where xx are digits indicating driver option)
        Cxx (where xx are digits indicating construction codes)
        F35 or F47 (Code indicating NSF compliant Gloss White paint -- may or
        may not appear, but these are the only allowed paints for exposed
        parts when Code X5 is used))
        Kxx (where xx are digits indicating packaging option)
        Pxx (where xx are 2 digits indicating lens thickness and material)
        Rxx (where xxx are digits indicating reflector option)
        Vxx (where xx are digits indicating wiring option)
        Xxx (where xx are digits indicating other approval options)
[5] (1)  Fixture type: i,o
    (2)  Fixture nominal size
         [Digits denoting size in format Width X Length (in feet, inches or
         in millimeters)]
    (3)  Door Gauge - Alpha numeric digit indicating metal gauge
    (4)  Housing Gauge, Alpha numeric digit indicating metal gauge
    (5)  Digit indicating Colour Rendering Index (CRI)
    (6)  Alpha/numeric digits indicating Colour Temperature.
    (7)  Alpha/numeric digits indicating lumen output. Alternatively,
         this could be 2 Lumen code separated by a slash (/) for white
         and single colour lumen outputs.
    (8)  Alpha/numeric digits indicating voltage
    (9)  Alpha-numeric code indicating lens thickness and material
         NOTE: The room side lens MUST be NSF compliant.
    (10) 1 or more optional suffixes may appear [OPTIONAL)
         Bxx (where xx are digits indicating driver option)
         Cxx (where xx are digits indicating construction code)
         F35 or F47 (Code indicating NSF compliant Gloss White paint -- may
         or may not appear, but these are the only allowed paints for
         exposed parts)
         Kxx (where xx are digits indicating packaging options)
         Mxx (where xx are digits indicating mounting options)
         Txx (where xx are digits indicating fusing options)
         Rxx (where xxx are digits indicating reflector option)
         VFx (where x is digit indicating reflector option)
         Vxx (where xx are digits indicating wiring option)
         Xxx (where xx are digits indicating certification)
[6] (1) Fixture type [OPTIONAL]
        G, GP, GR, P, R, X
    (2) Fixture model Optional
        xxxx (where xxxx is a 4 digit model number)
    (3) Fixture Nominal Size
        1x1 (Width X Length format in feet)
        1x2 (Width X Length format in feet)
        1X3 (Width X Length format in feet)
        1X4 (Width X Length format in feet)
        2X2 (Width X Length format in feet)
        2X4 (Width X Length format in feet) 
    (4) Digit indicating number of lamps –OR- LED
    (5) Alpha/numeric digits indicating lamp type -OR- Digit indicating color rendering 
        index (CRI)
    (6) Digits indicating lamp watts –OR- Alpha/numeric digits indicating Colour
        Temperature.
    (7) Alpha/numeric digits indicating ballast type -OR- Alpha/numeric digits indicating 
        lumen output.
    (8) Alpha/numeric digit indicating voltage
    (9) 1 or more optional suffixes may appear
        Bxx (where xx are digits indicating ballast or driver option)
        Cxx (where xx are digits indicating construction code)
        D3
        D9
        D10
        D17
        D18
        F35 or F47 (Code indicating NSF compliant Gloss White paint -- may or may not
        appear, but these are the only allowed paints for exposed parts when Code X5 
        is used)
        K0
        Mxx (where xx are digits indicating mounting options)
        Pxx (where xx are 2 digits indicating lens thickness and material)
        T5
        T6
        Rxx (where xxx are digits indicating reflector option)
        VFx (where x is digit indicating reflector option)
        Vxx (where xx are digits indicating wiring option)
        X1
        X3
        X4
        X7
        X8
        Z1(xxx) (Where xxx are 3 digits indication light colour
[7] (1) Reflector size
        6 (6" diameter)
        4 (4" diameter)				
    (2) Trim
        RSL (regressed sealed lens)
        FSL (flush sealed lens)
        FSS (flush sealed lens with screws)
        FST (flush sealed lens with tamper resistant screws)				
    (3) Reflector Finish
        PL (platinum - clear matte)
        SS (semi-specular)
        MW (painted matte white)
        GW (painted gloss white)				
    (4) Reflector distribution
        Alpha numeric digits indicating photometric beam angle or pattern				
    (5) Alpha numeric digits indicating CRI				
    (6) Alpha numeric digits indicating CCT				
    (7) Alpha numeric digits indicating nominal lumen output				
    (8) Alpha numeric digits indicating input voltage				
    (9) Alpha numeric digits indicating driver options				
    (10) Alpha numeric digits indicating additional options including but limited to the 
         below: 
         Cxx (where xx are digits indicating construction code)
         Fxx (where xx are digits indicating Paint colour.  Must be either F35 or F47 when
    X5 
         (Food Zone) is chosen)
         Kxx (where xx are digits indicating packaging options)
         Mxx (where xx are digits indicating mounting options)
         Pxx (where xx are 2 digits indicating lens thickness and material)
         Rxx (where xxx are digits indicating reflector option)
         Txx (where xx are digits indicating fusing options)
         VFx (where x is digit indicating reflector option)
         Vxx (where xx are digits indicating wiring option)
         Xxx (where xx are digits indicating certification)


Number of matching Manufacturers is 1
Number of matching Products is 16
Processing time was 0 seconds