NSF Product and Service Listings

These NSF Official Listings are current as of Thursday, November 7, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/food/Listings.asp?Standard=003&Company=C0338654&


NSF/ANSI 3
Commercial Warewashing Equipment

Racks per Hour / Dishes per Hour / Water Consumption Calculations

For informational purposes, the estimated racks per hour or dishes per hour for NSF/ANSI 3 Certified dishwashers can be calculated as follows:

Racks per Hour for Stationary Rack Dishwashers = 3600(NR) / TC

Racks per Hour for Rack Conveyor Dishwashers = (CS)(60) / RL

Dishes per Hour for Rackless Conveyor Dishwashers = (120)(CS)(CW) / PD

Water Consumption (gallons per hour) for Stationary Rack Dishwashers = (GPC)(RPH)

Water Consumption (gallons per hour) for Conveyor Dishwashers = (GPM)(60)

Where: CS = Conveyor speed measured in feet per minute
              CW = Conveyor width measured in inches
              GPC = Gallons per cycle
              GPM = Gallons per minute
              NR = Number of racks the dishwasher is designed to hold per cycle
              PD = Distance between pegs measured in inches, center to center of the peg, in the direction of conveyor travel
              RL = Length of the rack measured in feet
              RPH = Racks per hour
              TC = Total cycle time measured in seconds

The total cycle time includes wash, rinse, dwell, and load times. Load times will vary depending on the type of dishwasher. Estimated load times commonly used for specific types of dishwashers are as follows:
door type (straight thru) - 5 seconds
door type (corner) - 7 seconds
hood type - 8 seconds
front opening type - 30 seconds



 
Noble Chemical, Inc. 
2205 Old Philadelphia Pike
Lancaster, PA 17602 
United States 
888-256-6400 
717-291-9700
Visit this company's website

Facility : Barbourville, KY


CONVEYOR DISHWASHING MACHINES
      Final Rinse    
      (20 psi) Conveyor Speed  
  Model Conveyor Flow Usage (Max.) Footnotes
  Number Width gpm gph (ft/min.)  

Single Tank Rack Conveyor - Hot Water Sanitizing[1]
  WareForce 44H 20x20  2.6   154.3   6.2   [2] [3]
  WareForce 66H 20x20  2.6   154.3   6.2   [2] [3] [4]
  WareForce RS44 20x20  1.95   117   6.41   [6]
  WareForce RS44 20x20  1.16   69.8   6.41   [5]
  WareForce RS44S 20x20  1.16   69.8   6.41   [5]
  WareForce RS44S 20x20  1.95   117   6.41   [6]
  WareForce RS66 20x20  2.54   152.4   6.1   [6]
  WareForce RS66 20x20  1.18   70.74   6.1   [5]
  WareForce RS66S 20x20  1.18   70.74   6.1   [5]
  WareForce RS66S 20x20  2.54   152.4   6.1   [6]
 
[1] Unit may be equipped with modular heat recovery/vapor removal system that is connected
    on both the load and unload ends of the unit.  Modules may use existing installation
    ventilation system to move vapor or may be equipped with ventilation fans to move air as
    required.
[2] Units produced after February 15, 2007 may be dual temperature convertible models.
[3] Final rinse flow and usage are based on a 15 PSI flow pressure.
[4] With recirculated prewash.  Prewash temperature 110° - 140°F is obtained from wash tank
    overflow and fresh water supply.
[5] Model designation may have suffix S for steam heated and/or suffix C for a CREW style
    rack conveyor machine.
[6] Units may come equipped with additional rinse arms for use in "Turbo" rinse mode, which
    results greater water consumption.  This is not a post sanitizing rinse.

COMPONENTS:

Single Tank Rack Conveyor - Chemical Sanitizing[1]
  AJ-44 20x20  3.9   234   6.5   [2] [7] [8]
  AJ-66 20x20  3.9   234   6.5   [2] [4] [7] [8]
  AJ-80 20x20  3.9   234   6.9   [2] [4] [7] [8]
  AJX-44 20x20  2.7   164.4   5.8   [2] [3] [8] [9]
  AJX-54 20x20  2.6   154.3   6.2   [2] [3] [9]
  AJX-66 20x20  2.7   164.4   5.8   [3] [4] [8] [9]
  AJX-76 20x20  2.6   154.3   6.2   [2] [3] [4] [8] [9]
  AJX-80 20x20  2.7   164.4   5.8   [2] [3] [4] [8] [9]
  AJX-90 20x20  2.6   154.3   6.2   [2] [3] [4] [8] [9]
  CON44 20x20  1.16   69.8   6.41   [5]
  CON66 20x20  1.18   70.74   6.1   [5]
  CON80 20x20  1.18   70.74   6.1   [2] [3] [4] [8] [9]
  CREW 44 20x20  1.16   69.8   6.41   [5]
  CREW 44S 20x20  1.16   69.8   6.41   [5]
  CREW 66 20x20  1.18   70.74   6.1   [5]
  CREW 66S 20x20  1.18   70.74   6.1   [5]
  CREW 80 20x20  1.18   70.74   6.1   [5]
  CREW 80S 20x20  1.18   70.74   6.1   [5]
  RackStar 44 20x20  1.16   69.8   6.41   [5]
  RackStar 44 20x20  1.95   117   6.41   [6]
  RackStar 44S 20x20  1.95   117   6.41   [6]
  RackStar 44S 20x20  1.16   69.8   6.41   [5]
  RackStar 66 20x20  2.54   152.4   6.1   [6]
  RackStar 66 20x20  1.18   70.74   6.1   [5]
  RackStar 66S 20x20  1.18   70.74   6.1   [5]
  RackStar 66S 20x20  2.54   152.4   6.1   [6]
  WareForce 44L 20x20  2.7   164.4   5.8   [2] [8]
  WareForce 66L 20x20  2.7   164.4   5.8   [2] [3] [4] [8]
  WareForce C44 20x20  1.16   69.8   6.41   [5]
  WareForce C44S 20x20  1.16   69.8   6.41   [5]
  WareForce C66 20x20  1.18   70.74   6.1   [5]
  WareForce C66S 20x20  1.18   70.74   6.1   [5]
  WareForce C80 20x20  1.18   70.74   6.1   [5]
  WareForce C80S 20x20  1.18   70.74   6.1   [5]
  WareForce RS44 20x20  1.16   69.8   6.41   [5]
  WareForce RS44 20x20  1.95   117   6.41   [6]
  WareForce RS44S 20x20  1.95   117   6.41   [6]
  WareForce RS44S 20x20  1.16   69.8   6.41   [5]
  WareForce RS66 20x20  1.18   70.74   6.1   [5]
  WareForce RS66 20x20  2.54   152.4   6.1   [6]
  WareForce RS66S 20x20  2.54   152.4   6.1   [6]
  WareForce RS66S 20x20  1.18   70.74   6.1   [5]
 
[1] Unit may be equipped with modular heat recovery/vapor removal system that is connected
    on both the load and unload ends of the unit.  Modules may use existing installation
    ventilation system to move vapor or may be equipped with ventilation fans to move air as
    required.
[2] Units produced after February 15, 2007 may be dual temperature convertible models.
[3] Final rinse flow and usage are based on a 15 PSI flow pressure.
[4] With recirculated prewash.  Prewash temperature 110° - 140°F is obtained from wash tank
    overflow and fresh water supply.
[5] Model designation may have suffix S for steam heated and/or suffix C for a CREW style
    rack conveyor machine.
[6] Units may come equipped with additional rinse arms for use in "Turbo" rinse mode, which
    results greater water consumption.  This is not a post sanitizing rinse.
[7] Model designation may have suffix CEL for electrically heated or CSL for steam heated.
[8] Nonrecirculated, fresh water, final rinse, 50 ppm available chlorine.
[9] Model designation may have suffix CE for electrically heated, CG for gas heated, or S
    for steam heated.


GLASSWASHING MACHINES

Chemical Sanitizing Conveyor Glasswasher
  WareForce CG-115
  WareForce CG1200


STATIONARY RACK DISHWASHING MACHINES
      Final Rinse    
      (20 psi) Operating Time  
  Model Rack Size Flow Usage (seconds) Footnotes
  Number Width gpm gph Wash Rinse Dwell  

Single Tank Door - Chemical Sanitizing
  WareForce 1 HH 20x20  N/A   62.8   43   25   18   
  WareForce 1-E 20x20  N/A   40.2   42   25   20   [1] [2] [3]
  WareForce DG 20x20  N/A   36   43   24   18   
  WareForce I 20x20  N/A   40.2   42   25   20   [1] [2] [3]
  WareForce I-X 20x20  N/A   40.2   42   25   20   [1] [2] [3]
  WareForce II 2(20x20)  11.9   91.26   53   14   20   [3] [4] [5] [6] [7] [8] [9]
  WareForce II-C 2(20x20)  11.9   86.6   53   14   28   [4] [5] [6] [7] [8] [9]
 
[1] Recirculated pumped rinse, minimum 50 ppm available chlorine.
[2] Models may have ability for multiple cylcle times: 90 seconds, 2 minutes or 6 minutes.
[3] Model has the option of an available detergent dispenser.
[4] Accepted only with Jackson chemical feeders, peristaltic pump or pinch valve.
[5] Single tank machine utilizing two racks per complete operating cycle.
[6] Pumped rinse, minimum 50 ppm available chlorine, minimum 120°F.
[7] Unit equipped with a multiple setting time delay feature to extend wash times.  Maximum
    wash time time delays are 5 minutes.
[8] Suffix CML or CMR may appear. CML indicates corner machine left. CMR indicates corner
    machine right.
[9] Dwell includes drain and fill cycles.

Single Tank Door - Hot Water Sanitizing
  WareForce HT-180 20x20  4.1   51.6   40   13   4   [10] [11] [12]
  WareForce HT-180DT 20x20  3.78   39.5   40   11   7   [10] [12] [13]
  WareForce HT-180DTN 20x20  3.78   39.5   40   11   7   [10] [12] [13] [15]
  WareForce HT-180DTS 20x20  3.78   39.5   40   11   7   [10] [12] [13] [16]
  WareForce HT-180HH 20x20  5.46   72   45   15   2   [10] [11] [12] [14]
 
[10] Non-recirculated fresh water final rinse.
[11] Model designation may have suffix /NB to indicate that the unit does not come with an
     integral booster and must be supplied with a minimum 180°F fresh water hook-up or GP or
     GPX to indicate gas heated model.  Gas heated machines have a single-source gas booster
     which maintains the appropriate wash tank temperature.  Models without a suffix come
     with an integral booster for a minimum 40°F rinse temperature rise.
[12] Unit may be equipped with optional condensate removal system.
[13] Final rinse pressure of 8-12PSI	.
[14] Unit equipped with a multiple setting time delay feature to extend wash times.  Maximum
     wash time delays are 5 minutes.
[15] Suffix N indicates unit not supplied with booster heater and must be supplied with 180°
     water supply.
[16] Steam heated model	.

COMPONENTS:

Single Tank Door - Chemical Sanitizing
  WareForce UL30 20x20  6.6   28.8   56   35   26   [9]
 
[9] Dwell includes drain and fill cycles.


Number of matching Manufacturers is 1
Number of matching Products is 67
Processing time was 0 seconds