NSF Product and Service Listings
These NSF Official Listings are current as of Wednesday, July 16, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/food/Listings.asp?Standard=002&Company=C0536624&
NSF/ANSI 2
Food Equipment
Food Equipment
Pa-Co Lighting Inc. | |
780 Salaberry | |
Laval, QC H7S 1H3 | |
Canada | |
450-668-9620 |
Facility : Laval, Québec, Canada
Light Fixtures for Splash Zone and Non-Food Zone |
|
MD(0)(1)-(2)-(3)-(4)-(5)-FL-AM-(6)-(7) [1] | |
MR(0)(1)-(2)-(3)-(4)-(5)-(6)-(7)-(8)-AM[2] | |
MR(0)A(1)-(9)-(2)-(3)-(4)-(5)-(6)-(7)-(8)-AM[2] | |
MURA-(1)-(2)F-(3)-(4)-(5)-(6)-(7)-(8)-(9)-(10)-(11)[5] | |
P(1)CL-(2)-14-(3)-(4)-(5)[3] | |
P(1)CL-(2)-22-(3)-(4)-(5)[3] | |
P(1)CL-(2)-24-(3)-(4)-(5)[3] | |
V(1)4(2)-(3)F-(4)-(5)-(6)-(7)-(8)-(9)-(10)[4] | |
[1] (0) Indicates Usage - Either S or *Blank* (S - Surgical Suite, *Blank* - Elsewhere) (1) Indicates Size - Either 4 or 6 (2) Indicates Lumen Output (3) Indicates CRI - Either 8 or 9 (4) Indicates CCT (5) Indicates Internal Reflector Color MW - Matte White SS - Semi-Specular FL - Flush Lens AM - Anti-Microbial Finish (6) Indicates Voltage - Either MV=120/277v or 347=347v (7) Indicates Internal Reflector Version W - Wide M - Medium [2] (0) Indicates Usage - Either G or P (G - General, P - Patient) (1) Indicates Version - Either 1, 2, 3, 4, 5 or 6 (Internal Lighting Configurations) (2) Indicates Size - Either 14, 22 or 24 (3) Indicates Mounting - Either T or F (T - T-Bar, F - Plaster Frame) (4) Indicates Lumen Output (5) Indicates CRI - (Either 8 or 9) (6) Indicates CCT (7) Indicates External Lens Type - Acrylic or Polycarbonate (8) Indicates Voltage - Either MV - 120/277v or 347 - 347v AM - Anti-Microbial Finish (9) Indicates Security Level - Thickness of the door frame [3] (1) Indicates 'R' for In-ceiling or 'U' for Under-ceiling (2) Indicates installation options T for T-Bar or F for Recessed (3) Indicates Lumen Output (4) Indicates Lens Type - Acrylic or Polycarbonate (5) indicates voltage MV or 347 [4] (1) Indicates Mounting - T,R,S,P (T=T-Bar, R=Recessed, S=Surface, P=Pendant) (2) Indicates model - (M: Medical, C: Canopy (3) Indicates Length - In Feet (4) Indicates Lumen Output (5) Indicates CRI - (Either 8 or 9) (6) Indicates CCT (7) Indicates Voltage - Either MV=120/277v or 347=347v (8) Indicates Finish (9) Indicates options - Emergency, canopy) (10) Indicates Dimming type [5] (1) Indicates Version - Either X, H, M, L, HS, MS, LS, HB, MB, or LB (Different Thicknesses of Steel and Stainless Steel) (2) Indicates Length - Either 2, 3 or 4 (Fixture Length in Feet) (3) Indicates Lumen Output Up (4) Indicates Lumen Output Down (5) Indicates CRI - (Either 8 or 9) (6) Indicates CCT (7) Indicates Internal Diffuser Lens Type - Either FA1 or H5 (Acrylic) (8) Indicates External Lens - Either G1, M1, M3, M4, M5, M6, T5 or T6 (Polycarbonate or Tempered Glass Thickness) (9) Indicates Voltage - Either MV=120/277v or 347=347v (10) Indicates Internal Circuits - Either 1C or 2C (11) Driver Options - Either ND, D, D1, DA (Different Options for Internal Drivers) AM - Anti-Microbial Finish |
|
Medical Steplight for Splash Zone and Non-Food Zone |
|
M(1)L(2)-(3)-(4)-(5)-(6)-(7)-(8)[6] | |
[6] (1) N or T - N: Nightlight T: Tasklight (2) A or none - A: Anti-vandal (3) Indicates Lumens Output- Either W02 (20lm) - W05 (50lm) - W1 (100lm) (4) Indicates CRI - Either 8 or 9 (5) Indicates CCT (6) Indicates Voltage - either 120 or 277 (7) Indicates Finish (8) Indicates Options - Either Photocell sensor or Adjustable two-side junction box |
Number of matching Manufacturers is 1
Number of matching Products is 9