NSF Product and Service Listings

These NSF Official Listings are current as of Thursday, July 17, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/food/Listings.asp?Standard=169&Company=C0844370&


NSF/ANSI 169
Special Purpose Food Equipment and Devices



 
ODE (HK) Company Limited 
Room 712, Ocean Centre
Harbour City, Canton Road, TST 
Kowloon, Hong Kong 
China 
852 3841 6688

Facility : # 1 China


COMPONENTS:

BV Series[5] [7]
  BV(9)(10)(1)-(7)
 
[5] (1) One character indicating body material.
    (2) Type of body connection(1,A,B,D,F,G).
    (3) Type of fix core, one or two characters.
    (4) One character indicating copper ring.
    (5) One character indicating seal material.
    (6) Diameter of orifice(1.0 mm, 1.2 mm, 1.5 mm, 1.7 mm, 2.0 mm, 2.3 mm, 2.5 mm).
    (7) Internal code.
    (8) Fluidific function.
    (9) Elements number.
    (10) Elements type, one to six characters.
    (11) Voltage range, two or three characters.
    (12) Coil type, one to four characters.
    (13) Nature of supply, one character.
    (15) One character indicating DC voltage or AC voltage.
    (16) Three characters indicating voltage value.
    (17) Two to four characters indicating internal code.
    (18) One character indicating special requirement of customer or no character.
[7] Acceptable for contact with non-carbonated potable water and steam.

D21Series[5] [7]
  D21J(1)(2)(3)(4)(5)(6)-(11)(12)-(7)
  D21J(1)(2)(3)(4)(5)(6)-(7)-(12)
 
[5] (1) One character indicating body material.
    (2) Type of body connection(1,A,B,D,F,G).
    (3) Type of fix core, one or two characters.
    (4) One character indicating copper ring.
    (5) One character indicating seal material.
    (6) Diameter of orifice(1.0 mm, 1.2 mm, 1.5 mm, 1.7 mm, 2.0 mm, 2.3 mm, 2.5 mm).
    (7) Internal code.
    (8) Fluidific function.
    (9) Elements number.
    (10) Elements type, one to six characters.
    (11) Voltage range, two or three characters.
    (12) Coil type, one to four characters.
    (13) Nature of supply, one character.
    (15) One character indicating DC voltage or AC voltage.
    (16) Three characters indicating voltage value.
    (17) Two to four characters indicating internal code.
    (18) One character indicating special requirement of customer or no character.
[7] Acceptable for contact with non-carbonated potable water and steam.

D31Series[5] [7]
  5696(3)(4)(5)(6)-(12)
  D31J(1)(2)(3)(4)(5)(6)-(11)(12)-(7)
  D31J(1)(2)(3)(4)(5)(6)-(7)-(12)
 
[5] (1) One character indicating body material.
    (2) Type of body connection(1,A,B,D,F,G).
    (3) Type of fix core, one or two characters.
    (4) One character indicating copper ring.
    (5) One character indicating seal material.
    (6) Diameter of orifice(1.0 mm, 1.2 mm, 1.5 mm, 1.7 mm, 2.0 mm, 2.3 mm, 2.5 mm).
    (7) Internal code.
    (8) Fluidific function.
    (9) Elements number.
    (10) Elements type, one to six characters.
    (11) Voltage range, two or three characters.
    (12) Coil type, one to four characters.
    (13) Nature of supply, one character.
    (15) One character indicating DC voltage or AC voltage.
    (16) Three characters indicating voltage value.
    (17) Two to four characters indicating internal code.
    (18) One character indicating special requirement of customer or no character.
[7] Acceptable for contact with non-carbonated potable water and steam.

Flow Meter[1] [4]
  AB32
  AD72
  AH97
  AK66
 
[1] Approved for water contact only.
[4] With the following sizes of orifices; 1.0 mm - 4.0mm

IL Series[5] [7]
  2(8)IL(1)(2)(3)(6)(11)(13)
  2(8)IL(1)(2)(3)(6)(11)(13)-(7)
 
[5] (1) One character indicating body material.
    (2) Type of body connection(1,A,B,D,F,G).
    (3) Type of fix core, one or two characters.
    (4) One character indicating copper ring.
    (5) One character indicating seal material.
    (6) Diameter of orifice(1.0 mm, 1.2 mm, 1.5 mm, 1.7 mm, 2.0 mm, 2.3 mm, 2.5 mm).
    (7) Internal code.
    (8) Fluidific function.
    (9) Elements number.
    (10) Elements type, one to six characters.
    (11) Voltage range, two or three characters.
    (12) Coil type, one to four characters.
    (13) Nature of supply, one character.
    (15) One character indicating DC voltage or AC voltage.
    (16) Three characters indicating voltage value.
    (17) Two to four characters indicating internal code.
    (18) One character indicating special requirement of customer or no character.
[7] Acceptable for contact with non-carbonated potable water and steam.

Solenoid Pump
  Phoenix(1)[1] [2] [3]
 
[1] Approved for water contact only.
[2] (1) Two digit suffix indicating plunger size.
[3] May be followed by suffix 'N' representing customer specific request.

Solenoid Valve
  AL26 series[5] [6]
  AL26-(15)(16)-(17)-(18)
 
[5] (1) One character indicating body material.
    (2) Type of body connection(1,A,B,D,F,G).
    (3) Type of fix core, one or two characters.
    (4) One character indicating copper ring.
    (5) One character indicating seal material.
    (6) Diameter of orifice(1.0 mm, 1.2 mm, 1.5 mm, 1.7 mm, 2.0 mm, 2.3 mm, 2.5 mm).
    (7) Internal code.
    (8) Fluidific function.
    (9) Elements number.
    (10) Elements type, one to six characters.
    (11) Voltage range, two or three characters.
    (12) Coil type, one to four characters.
    (13) Nature of supply, one character.
    (15) One character indicating DC voltage or AC voltage.
    (16) Three characters indicating voltage value.
    (17) Two to four characters indicating internal code.
    (18) One character indicating special requirement of customer or no character.
[6] Acceptable for contact with non-carbonated potable water only.


Number of matching Manufacturers is 1
Number of matching Products is 15
Processing time was 0 seconds