NSF/ANSI/3-A 14159-1
Hygiene Requirements for the Design of
Meat and Poultry Processing Equipment
Facility : Charlotte, NC
COMPONENTS:
Generation 2 Worm Gear Speed Reducer[1]
|
| SS(1)(2)(3)7180(4)-(5)(6)(7)-(8)-(9)(10)-(11)-(12)-(13) |
[1] (1) OP STYLE denoted by:
BLANK - SOLID OUTPUT SHAFT
H - HOLLOW OUTPUT
(2) MOTOR FLANGE denoted by
F - QUILL STYLE MOTOR FLANGE
QC - QUICK CONNECT MOTOR FLANGE
(3) REDUCTION TYPE denoted by:
BLANK - SINGLE REDUCTION
WP - DOUBLE W/ PLANETARY PREFIX
WA - COMPOUND A ORIENTATION
WB - COMPOUND B ORIENTATION
WC - COMPOUND C ORIENTATION
WD - COMPOUND D ORIENTATION
(4) BASE denoted by:
BLANK - NO BASE
B - HORIZONTAL BASE
V - OUTPUT FLANGE - RIGHT
W - OUTPUT FLANGE - LEFT
T - TORQUE ARM
(5) RATIO denoted by:
Single Reduction Valid Values from 5 to 100
Compound WA / WB / WC / WD Valid Values from 100 to 10,000
Planetary WP Valid Values from 25 to 500
(6) LUBRICATION denoted by
BLANK - No Lubrication
K - Kluber UH1 6-460
D - Mobil SHC Cibus 460
(7) SEAL OPTIONS denoted by:
C - IP69k rated OP seals
CT - IP69k OP seals and double IP seals
(8) NEMA MOTOR MOUNTING denoted by:
B5 - 56C
B7 - 140TC
B9 - 180TC
B11 - 210TC
(9) OUTPUT SHAFT denoted by
GS - OUTPUT LEFT
HS - DOUBLE PROJECTION
JS - OUTPUT RIGHT
(10) MOUNTING POSITION (non-blank value req'd if K or D lubrication) denoted by:
BLANK (only if no lube)
1
2
3
4
5
6
(11) OP BORE CODE (for hollow OP shaft only) denoted by:
AP(Inch) or APM (Metric) followed by two digits denoting size
P (Inch) or PM (Metric) followed by two digits denoting size
TP (Inch) or TPM (Metric) followed by two digits denoting size
(12) MOTOR (optional) denoted by:
FUTSS
GUTSS
HUT58SS
HUTF-5/8SS
HUTSS
HUTFSS
JUTFSS
KUTFSS
LUTFSS
MUTFSS
NUTFSS
PUTFSS
(13) CONDUIT BOX LOCATION (if motor provided) denoted by:
0
3
6
9
|
Stainless Steel Worm Gear Speed Reducer[2]
|
| SS(1)713(2)(3)(4)(5)(6)(7) |
|
| SS(1)715(2)(3)(4)(5)(6)(7) |
[2] May have the following suffixes:
(1) Optional Input Style Designation. Valid Values are F and QC
(2) Optional Mounting Base. Valid values are B, V, W, and blank.
(3) Gear ratio. A ratio is required. Valid values are 5 to 100.
(4) Indicates the unit is filled with synthetic food grade lubricant.
Blank means the unit has no lubricant.
Valid values are K, D and Blank.
K - Kluber UH1 6-460
D - Mobil SHC Cibus 460
(5) Motor mounting. A motor mounting is required. Valid values are
B5, B7, B9, B11.
(6) Shaft style. A shaft style is required. GS, HS, JS are valid values.
(7) Optional mounting position designation. Valid values are
1, 2, 3, 4, 5, 6, Blank.
(8) Shaft bore designation. Required for any SSH type unit. Valid values
are P or PM followed by two digits denoting bore size.
|
Generation 2 Worm Gear Speed Reducer[1]
|
| SS(1)(2)(3)7210(4)-(5)(6)(7)-(8)-(9)(10)-(11)-(12)-(13) |
[1] (1) OP STYLE denoted by:
BLANK - SOLID OUTPUT SHAFT
H - HOLLOW OUTPUT
(2) MOTOR FLANGE denoted by
F - QUILL STYLE MOTOR FLANGE
QC - QUICK CONNECT MOTOR FLANGE
(3) REDUCTION TYPE denoted by:
BLANK - SINGLE REDUCTION
WP - DOUBLE W/ PLANETARY PREFIX
WA - COMPOUND A ORIENTATION
WB - COMPOUND B ORIENTATION
WC - COMPOUND C ORIENTATION
WD - COMPOUND D ORIENTATION
(4) BASE denoted by:
BLANK - NO BASE
B - HORIZONTAL BASE
V - OUTPUT FLANGE - RIGHT
W - OUTPUT FLANGE - LEFT
T - TORQUE ARM
(5) RATIO denoted by:
Single Reduction Valid Values from 5 to 100
Compound WA / WB / WC / WD Valid Values from 100 to 10,000
Planetary WP Valid Values from 25 to 500
(6) LUBRICATION denoted by
BLANK - No Lubrication
K - Kluber UH1 6-460
D - Mobil SHC Cibus 460
(7) SEAL OPTIONS denoted by:
C - IP69k rated OP seals
CT - IP69k OP seals and double IP seals
(8) NEMA MOTOR MOUNTING denoted by:
B5 - 56C
B7 - 140TC
B9 - 180TC
B11 - 210TC
(9) OUTPUT SHAFT denoted by
GS - OUTPUT LEFT
HS - DOUBLE PROJECTION
JS - OUTPUT RIGHT
(10) MOUNTING POSITION (non-blank value req'd if K or D lubrication) denoted by:
BLANK (only if no lube)
1
2
3
4
5
6
(11) OP BORE CODE (for hollow OP shaft only) denoted by:
AP(Inch) or APM (Metric) followed by two digits denoting size
P (Inch) or PM (Metric) followed by two digits denoting size
TP (Inch) or TPM (Metric) followed by two digits denoting size
(12) MOTOR (optional) denoted by:
FUTSS
GUTSS
HUT58SS
HUTF-5/8SS
HUTSS
HUTFSS
JUTFSS
KUTFSS
LUTFSS
MUTFSS
NUTFSS
PUTFSS
(13) CONDUIT BOX LOCATION (if motor provided) denoted by:
0
3
6
9
|
Stainless Steel Worm Gear Speed Reducer[2]
|
| SS(1)718(2)(3)(4)(5)(6)(7) |
[2] May have the following suffixes:
(1) Optional Input Style Designation. Valid Values are F and QC
(2) Optional Mounting Base. Valid values are B, V, W, and blank.
(3) Gear ratio. A ratio is required. Valid values are 5 to 100.
(4) Indicates the unit is filled with synthetic food grade lubricant.
Blank means the unit has no lubricant.
Valid values are K, D and Blank.
K - Kluber UH1 6-460
D - Mobil SHC Cibus 460
(5) Motor mounting. A motor mounting is required. Valid values are
B5, B7, B9, B11.
(6) Shaft style. A shaft style is required. GS, HS, JS are valid values.
(7) Optional mounting position designation. Valid values are
1, 2, 3, 4, 5, 6, Blank.
(8) Shaft bore designation. Required for any SSH type unit. Valid values
are P or PM followed by two digits denoting bore size.
|
Generation 2 Worm Gear Speed Reducer[1]
|
| SS(1)(2)(3)7240(4)-(5)(6)(7)-(8)-(9)(10)-(11)-(12)-(13) |
|
| SS(1)(2)(3)7260(4)-(5)(6)(7)-(8)-(9)(10)-(11)-(12)-(13) |
[1] (1) OP STYLE denoted by:
BLANK - SOLID OUTPUT SHAFT
H - HOLLOW OUTPUT
(2) MOTOR FLANGE denoted by
F - QUILL STYLE MOTOR FLANGE
QC - QUICK CONNECT MOTOR FLANGE
(3) REDUCTION TYPE denoted by:
BLANK - SINGLE REDUCTION
WP - DOUBLE W/ PLANETARY PREFIX
WA - COMPOUND A ORIENTATION
WB - COMPOUND B ORIENTATION
WC - COMPOUND C ORIENTATION
WD - COMPOUND D ORIENTATION
(4) BASE denoted by:
BLANK - NO BASE
B - HORIZONTAL BASE
V - OUTPUT FLANGE - RIGHT
W - OUTPUT FLANGE - LEFT
T - TORQUE ARM
(5) RATIO denoted by:
Single Reduction Valid Values from 5 to 100
Compound WA / WB / WC / WD Valid Values from 100 to 10,000
Planetary WP Valid Values from 25 to 500
(6) LUBRICATION denoted by
BLANK - No Lubrication
K - Kluber UH1 6-460
D - Mobil SHC Cibus 460
(7) SEAL OPTIONS denoted by:
C - IP69k rated OP seals
CT - IP69k OP seals and double IP seals
(8) NEMA MOTOR MOUNTING denoted by:
B5 - 56C
B7 - 140TC
B9 - 180TC
B11 - 210TC
(9) OUTPUT SHAFT denoted by
GS - OUTPUT LEFT
HS - DOUBLE PROJECTION
JS - OUTPUT RIGHT
(10) MOUNTING POSITION (non-blank value req'd if K or D lubrication) denoted by:
BLANK (only if no lube)
1
2
3
4
5
6
(11) OP BORE CODE (for hollow OP shaft only) denoted by:
AP(Inch) or APM (Metric) followed by two digits denoting size
P (Inch) or PM (Metric) followed by two digits denoting size
TP (Inch) or TPM (Metric) followed by two digits denoting size
(12) MOTOR (optional) denoted by:
FUTSS
GUTSS
HUT58SS
HUTF-5/8SS
HUTSS
HUTFSS
JUTFSS
KUTFSS
LUTFSS
MUTFSS
NUTFSS
PUTFSS
(13) CONDUIT BOX LOCATION (if motor provided) denoted by:
0
3
6
9
|
Stainless Steel Worm Gear Speed Reducer[2]
|
| SS(1)724(2)(3)(4)(5)(6)(7) |
[2] May have the following suffixes:
(1) Optional Input Style Designation. Valid Values are F and QC
(2) Optional Mounting Base. Valid values are B, V, W, and blank.
(3) Gear ratio. A ratio is required. Valid values are 5 to 100.
(4) Indicates the unit is filled with synthetic food grade lubricant.
Blank means the unit has no lubricant.
Valid values are K, D and Blank.
K - Kluber UH1 6-460
D - Mobil SHC Cibus 460
(5) Motor mounting. A motor mounting is required. Valid values are
B5, B7, B9, B11.
(6) Shaft style. A shaft style is required. GS, HS, JS are valid values.
(7) Optional mounting position designation. Valid values are
1, 2, 3, 4, 5, 6, Blank.
(8) Shaft bore designation. Required for any SSH type unit. Valid values
are P or PM followed by two digits denoting bore size.
|
Generation 2 Worm Gear Speed Reducer[1]
|
| SS(1)(2)(3)7320(4)-(5)(6)(7)-(8)-(9)(10)-(11)-(12)-(13) |
[1] (1) OP STYLE denoted by:
BLANK - SOLID OUTPUT SHAFT
H - HOLLOW OUTPUT
(2) MOTOR FLANGE denoted by
F - QUILL STYLE MOTOR FLANGE
QC - QUICK CONNECT MOTOR FLANGE
(3) REDUCTION TYPE denoted by:
BLANK - SINGLE REDUCTION
WP - DOUBLE W/ PLANETARY PREFIX
WA - COMPOUND A ORIENTATION
WB - COMPOUND B ORIENTATION
WC - COMPOUND C ORIENTATION
WD - COMPOUND D ORIENTATION
(4) BASE denoted by:
BLANK - NO BASE
B - HORIZONTAL BASE
V - OUTPUT FLANGE - RIGHT
W - OUTPUT FLANGE - LEFT
T - TORQUE ARM
(5) RATIO denoted by:
Single Reduction Valid Values from 5 to 100
Compound WA / WB / WC / WD Valid Values from 100 to 10,000
Planetary WP Valid Values from 25 to 500
(6) LUBRICATION denoted by
BLANK - No Lubrication
K - Kluber UH1 6-460
D - Mobil SHC Cibus 460
(7) SEAL OPTIONS denoted by:
C - IP69k rated OP seals
CT - IP69k OP seals and double IP seals
(8) NEMA MOTOR MOUNTING denoted by:
B5 - 56C
B7 - 140TC
B9 - 180TC
B11 - 210TC
(9) OUTPUT SHAFT denoted by
GS - OUTPUT LEFT
HS - DOUBLE PROJECTION
JS - OUTPUT RIGHT
(10) MOUNTING POSITION (non-blank value req'd if K or D lubrication) denoted by:
BLANK (only if no lube)
1
2
3
4
5
6
(11) OP BORE CODE (for hollow OP shaft only) denoted by:
AP(Inch) or APM (Metric) followed by two digits denoting size
P (Inch) or PM (Metric) followed by two digits denoting size
TP (Inch) or TPM (Metric) followed by two digits denoting size
(12) MOTOR (optional) denoted by:
FUTSS
GUTSS
HUT58SS
HUTF-5/8SS
HUTSS
HUTFSS
JUTFSS
KUTFSS
LUTFSS
MUTFSS
NUTFSS
PUTFSS
(13) CONDUIT BOX LOCATION (if motor provided) denoted by:
0
3
6
9
|
Stainless Steel Worm Gear Speed Reducer[2]
|
| SS(1)726(2)(3)(4)(5)(6)(7) |
|
| SS(1)732(2)(3)(4)(5)(6)(7) |
|
| SSH(1)713(2)(3)(4)(5)(6)(7)(8) |
|
| SSH(1)715(2)(3)(4)(5)(6)(7)(8) |
|
| SSH(1)718(2)(3)(4)(5)(6)(7)(8) |
|
| SSH(1)721(2)(3)(4)(5)(6)(7)(8) |
|
| SSH(1)724(2)(3)(4)(5)(6)(7)(8) |
|
| SSH(1)726(2)(3)(4)(5)(6)(7)(8) |
|
| SSH(1)732(2)(3)(4)(5)(6)(7)(8) |
[2] May have the following suffixes:
(1) Optional Input Style Designation. Valid Values are F and QC
(2) Optional Mounting Base. Valid values are B, V, W, and blank.
(3) Gear ratio. A ratio is required. Valid values are 5 to 100.
(4) Indicates the unit is filled with synthetic food grade lubricant.
Blank means the unit has no lubricant.
Valid values are K, D and Blank.
K - Kluber UH1 6-460
D - Mobil SHC Cibus 460
(5) Motor mounting. A motor mounting is required. Valid values are
B5, B7, B9, B11.
(6) Shaft style. A shaft style is required. GS, HS, JS are valid values.
(7) Optional mounting position designation. Valid values are
1, 2, 3, 4, 5, 6, Blank.
(8) Shaft bore designation. Required for any SSH type unit. Valid values
are P or PM followed by two digits denoting bore size.
|
Number of matching Manufacturers is 1
Number of matching Products is 18
Processing time was 0 seconds