Watts Regulator Company 
815 Chestnut Street
North Andover, MA 01845 
United States 
978-689-6165
Visit this company's website

Facility : # 1 Zhejiang, China


Vacuum Relief Valve[1] [LL]
   LFN36M1 1/2"-3/4"
   LFN36M1-CAN 1/2"-3/4"

[1] CAN - Indicates bilingual packaging and warning labels.
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Facility : # 2 Zhejiang, China


Test Cock[1] [2] [LL]
   SA-0125 NPT
   SA-0.25 NPT19044
   SA TC 1/8 SAE LL
   0.25 SA-TC-.25-LL
   0.125 SA-TC-.125-SAE-LL
   0.125 SA-TC-.125-NPT-LL
   0.125 LFNPT-TC
   SA-0.125 NPT-SAE19044
   0.25 SA-TC-.25-Z1-LL
   0.25 LFTC
   0.125 LFSAE-TC

[1] This product is only authorized for use in the closed position.
[2] Products may bear the optional trade name - with Cap.
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Facility : # 4 Zhejiang, China


Test Cock[1] [3] [LL]
   0.125 LFNPT-TC
   0.125 LFSAE-TC
   0.125 SA-TC-.125-NPT-LL
   0.125 SA-TC-.125-SAE-LL
   0.25 LFTC
   0.25 SA-TC-.25-LL
   0.25 SA-TC-.25-Z1-LL
   SA TC 1/8 SAE LL
   SA-0.125 NPT-SAE19044
   SA-0.25 NPT19044
   SA-0125 NPT

[1] This product is only authorized for use in the closed position.
[3] Products may bear the optional trade name - with Cap
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Valves[3] [LL]
   LFB6090
   LFB6091

[3] Products may bear the optional trade name - with Cap
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Facility : # 7 Zhejiang, China


Strainers[1] [LL]
   (1)LF351(2)(3)(4)A
   (1)LF352(2)(3)(4)A
   (1)LF358(2)(3)(4)A

[1] Can consist of any of the following:
    
    (1) Prefix - designating size
        25    - 1/4"
        .375  - 3/8"
        .50   - 1/2"
        .75   - 3/4"
        01.0  - 1"
        01.25 - 1 1/4"
        01.5  - 1 1/2"
        02.0  - 2"
        02.5  - 2 1/2"
        03.0  - 3"
    (2) Buy America Act (BAA) Compliance
        Blank - Standard Unit - US BAA compliant
        N     - Non - BAA Qualified
    (3) Strainer Screen Construction Options
        Blank - Standard Strainer Screen - 20 Mesh up to 2" Size, 1/16" Perf 2-1/2" & 3", 
                304 SS only.
        5101  - 20 Mesh Screen 	
        5102  - 30 Mesh Screen 	
        5109  - 1/16" Perforated Screen 
        5111  - 1/8" Perforated Screen
        5105  - 0.033" Perforated Screen
        5112  - 5/32" Perforated Screen
        5141  - 5/32" Perf, 20 Mesh Lined
        5142  - 5/32" Perf, 30 Mesh Lined
        5143  - 5/32" Perf, 40 Mesh Lined
        5144  - 5/32" Perf, 60 Mesh Lined
        5145  - 5/32" Perf, 80 Mesh Lined
        5146  - 5/32" Perf, 100 Mesh Lined
    (4) Strainer Screen Material Options
        Blank - Standard Strainer Screen - (3) is Blank (standard) and material is 304 
                (standard).
        08    - 304 Stainless Steel Screen Material
        04    - 316 Stainless Steel Screen Material
        05    - Monel Screen Material
    A - Suffix for Internal Use - Non-Standard Screen (No Options).
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Facility : Greenwood, IN


Tanks[LL]
   DETA-5 3.5 gallon
   DETA-12 5 gallon
   DETA-20 8 gallon
   DETA-30 15 gallon
   DETA-42 22 gallon
   DETA-60 26 gallon
   DETA-80 35 gallon
   DETA-100 45 gallon
   DETA-125 60 gallon
   DETA-160 70 gallon
   DETA-180 80 gallon
   DETA-210 90 gallon

[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Facility : Franklin, NH


Backflow Preventer [LL]
   3/4" LF9D-M2[1]
   3/4" LF9DS-M2[1]
   1/2" LF9D-M3[1]
   1/2" LF9DS-M3[1]
   1/2" - 3/4" LFBBFP[1]
   1/2" - 3/4" LFBBFPS[1]
   3/8" & 1/4" SD2[2] [3]
   3/8" & 1/4" SD3[2] [3]
   2 1/2" - 3" LF007(1)[4]
   2 1/2" - 3" LF009(1)[4]
   2 1/2" - 3" LF007DCDA(1)(2)[4]
   LFU719[5]
   LFU919[5]

[1] Optional Z8 (longer spring)
    Z9 Custom Product
    R-Can - Inlet and outlet adapters reversed 
    HT - Hose thread connection
[2] Models may have one or more of the following suffixes:
    FF - Female flare
    FN - Female NPT
    LS - Less strainer
    MF - Male flare
    MN - Male NPT
    Z  - Special packaging
    Z1 - Alternate adapter
    Z2 - Alternate adapter
[3] This product is also Listed to NSF Standard 18.
[4] Suffixes may consist of the following:
    (1) Isolation shut-off valve options
         LF   - Assembly ships without isolation shut-off valves
         NRS  - Non-rising stem
         DNRS - Domestic non-rising stem
         OSY  - Outside stem and yoke
         DOSY - Domestic outside stem and yoke
    (2) Water Meter Options
          -CFM Cubic Foot Meter
          -GPM Gallon Foot Meter
[5] Products may include one or more of the following prefixes or suffixes:
    S - Lead Free Strainer
    LF (as suffix) - Less fitting
    LF (as prefix) - Lead free
    QT - Quarter turn ball valve
    Options for non-wetted:
    C & T - Cap and tether test cock covers
    LH    - Locking handled ball valves
    SH    - Stainless handled ball valves
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Ball Valve[6] [LL]
   LFB6000 Standard Port, NPT End
   LFB6000-M2 Standard Port, NPT End
   LFB6001 Standard Port, Solder End
   LFB6001-M2 Standard Port, Solder End
   LFB6011-M2 Standard Port, Solder End (Union)
   LFB6080 Full Port, NPT End
   LFB6080-M1 Full Port, NPT End
   LFB6081 Full Port, Solder End
   LFB6081-M1 Full Port Solder End
   LFB6400 Standard Port, NPT End, Ball Valve with Actuator Mounting Pads
   LFB6780-M1 3-Way NPT End
   LFB6781 3-way NPT End Ball Valve Sweat End PP
   LFEMVII6400SS YYY-XX

[6] Suffix:
    AD   - Assembled dry
    BS   - Balance stop plate
    G    - Grounded ball and stem
    GS   - Grounded stem
    LC   - Latch lock handle – closed position
    LH   - Locking handle
    LL   - Latch lock handle
    OV   - Oval handle
    RH   - Round handle
    SC   - Sain chrome (body and adapter)
    SH   - Stainless handle
    TH   - Tee handle
    XH   - Extended handle
    XX   - Cycle time in seconds: 5-40
    YYY  - Motor voltage: 115 or 24
    Z15  - Without handle and nut
    Z107 - Without handle
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Check Valves[LL]
   LF601SDUP 1/4" - 2"
   LF601SDU 1/4" - 2"
   LF600 Series 1/4" - 2"
   LF601 Series 1/4" - 1/2"
   LF601S Series 1/2" - 1"
   LL390725

[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Commercial Relief Valves[7] [LL]
   LF140S 3/4" - 1"
   LF140X 3/4" - 1"
   LF174A 3/4" - 2"
   LF340 1 1/2"
   LF342 2"
   LF40L 3/4" - 1"
   LF40XL 3/4", 1"
   LF474A 3/4" - 1 1/4"
   LFLL40XL 3/4", 1"
   LFLLL40XL 3/4"
   LFM474A 3/4"
   LFN240X 1"
   LFN241X 1 1/4"

[7] Models may have one or more of the following suffixes:
    2-9  - Length of thermostat
    B    – British threads
    BULK – Bulk packed
    CAN  - Bilingual pakaging and warning tags
    FS - Flood Sensor
    M#   - Model number
    TT   – Teflon tape on the outside of the male NPT inlet thread
    X    - Extended length thermostat
    XXX  – Pressure range 30-150 or 75-175
    YYY  – Temp 100-210
    Z#   - Customer special
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Dielectric Unions[8] [LL]
   5DMG0
   5DMG1
   5DMG2
   5DMG3
   5DMG4
   5DMG5
   5DMG6
   5DMG7
   5DMG8
   5DMG9
   5DMH0
   5DMH1
   5DMH2
   5DMH3
   5DMH4
   5DMH5
   5DMH6
   LF3001A-(X)
   LF3002-(X)
   LF3003-(X)
   LF3004-(X)
   LF3005-(X)
   LF3005A-(X)
   LF3006-(X)
   LF3007-(X)
   LF3008-(X)
   LF3100-(X)
   LF3100M3
   LF3110-(X)
   LF3110-LF-(X)
   LF3200-(X)
   LF4001E-(X)

[8] -(X) Optional GB for High Temp models
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

End Point Control Valves[LL]
   0.5" LF150A
   0.75" LF150A-HA
   0.75" LF150HA
   0.375 LFUSG-CS

[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Irrigation and Trailer Regulator[9] [LL]
   LF(Z)560-(Y)-(VVV) - 0(XXX) 1/8" - 3/4"

[9] -(Y) Suffix:				
         Blank - No Gage			
         G     - Gage			
    -(XXX) - Spring ranges 20 - 125 psi		
    (Z) Suffix:				
        H     - Hose end connection .75" only	
        Blank - NPT End Connection 1/8" and 1/4"
    -(VVV) Suffix: 				
           BSP   - British Thread End Connection 1/8" and 1/4"
           Blank - NPT End Connection 1/8" and 1/4"
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Pressure Relief Valve[10] [LL]
   LF5300A-(X)
   LF530-C-(X)

[10] (X) Optional Suffix
         BSP Threads
         FP  - Fire rated
         Z4  - Slotted adjusting bolt
         Z6  - 80 Slotted Adjusting bolt preset 80 psi
         100 - 300 psi range
         80  - 175 psi range
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Residential Relief Valves[11] [LL]
   LF 100XL
   LF 100XL-4
   LF 100XL-8
   LF 100XL-TS-BP-1Z-075
   LF 1XL-TS-BP-Z1-075
   LF 3L
   LF 3L-Z3
   LF L100XL
   LF LL100XL
   LF LLL100XL
   LF SL100XL
   LF SL100XL 3M7Z18TT150
   LF100XL-Z19-TT150210
   LF4L
   LF53L
   LFLLL100XL 2M7Z 18TT150

[11] LF1L       - 1/2" Standard body with short 2" thermostat
     LF10L      - 3/4" Standard body with short 2" thermostat
     LF1XL      - 1/2" Standard body with long 4" or 8" thermostat
     LF100XL    - 3/4" Standard body with long 4" or 8" thermostat
     LFSL100XL  - Short length body
     LFL100XL   - Medium length body
     LFLL100XL  - Long body
     LFLLL100XL - Extra long body
     LF53L      - 1/2" Pressure relief valve w/ standard body
     LF3L       - 3/4" Pressure relief valve	w/ standard body
     LF4L       - 3/4" Pressure relief valve
     Trade names may have the following suffixes:
     X   - Thermostat length 2" - 8"
     YYY - Set pressures 30 thru 175 psi
     ZZZ - Set temperatures 180 or 210 def F
     BP  - Bulk Pack
     DP  - Display Pack
     TS  - Thread Sealant
     Z1  - Customer special (no warning tag)
     Z3  - Customer special (de-rated capacity to 200,000 BTU/HR)
     Z9  - Customer special (stainless steel lever)
     Z11 - Customer special (stainless steel lever and low temp thermostat)
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Strainers [LL]
   LF(Y)777(Z)-XXX 3" - 4"[12]
   LF(Y)777(Z)M1-XXX 1/4" - 1 1/2"[12]
   LF(Y)777(Z)M3-XXX 2" - 2 1/2"[12]
   LF27 (X)(Y)[13]
   LF745 3/4"[12]

[12] (Y) Blank threaded NPT end connections		
         S - Solder end connections		
     (Z) Blank plain strainer cap		
         S    - Taped strainer cap	
         PART - Replacement Part
         XXX  - Strainer screen sizes 03-100	
[13] (X) Suffix:
         B - British thread option
     (Y) Suffix Screen Mesh Size:
         24  - 100
     Z14 - Nickel Plated
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Tempering Valve [LL]
   LF(X)70A(Y)[14]
   LFN170M3[15]
   LFN170M3-CSUT[15]

[14] X 
     Blank - Standard temperature range (120-160°F)
     L     - Low temperature range (100-130°F)
     Y
     Blank - 3/4" Solder
     F     - 1/2" Solder
     T     - 1/2" or 3/4" Threaded
[15] LFN170      – without check stops
     LFN170-CSUT – with check stops
     Sizes are 3/4" - 2"
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Vacuum Breaker [LL]
   LF008 QTS[16]
   LF008 PCQTS[16]
   LF008 QT[16]
   LF008PCQT-SC[16]
   LF008 PCQTS-SC
   LF289[16]
   LF289C[16]

[16] C  - Chrome
     PC – Polycoating
     QT – Quarter turn
     SC – Satin chrome
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Vacuum Breaker Relief [LL]
   LF800M4XX[17]

[17] XX can include:
     QT - Quarter turn stops
     FR - Freeze Resistant
     SH - Stainless handles
     FZ - Freeze Sensor
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Valves [LL]
   1/4" - 3/8" LF215M1 (WW) (YY) (TT)[19]
   3/4" LF210-5 M2
   3/4" LFL210-5 M2
   3/4" LFLL210-5 M2
   3/4" LFLLL210-5 M2
   3" LF127W
   3" LFF127W
   4" LFF127W
   LFB6080G2
   LFB6081G2
   LFN250, 3/4"
   LFN250B, 1/2"
   LFN250B, 3/4"
   LFN250B-Z2, 3/4"
   LFN250B-Z2-020, 3/4"
   LFWDS-(1)[20]

[19] -(WW) Adjusting bolt 
           Blank tee handle 
           X Slotted 
     -(YY) Special configurations 
           Z2 tee handle adjusting screw 
           Z9 teflon diaphragm protector 
     -(TT) Pressure range 
           0-8 
           0-20 
           0-50
[20] (1) Power cut-off module options
         SP-R - Standing pilot right hand threaded
         SP-L - Standing pilot left hand threaded
         E220 - Electric
         SI   - Spark ignition
         ICN  - ICON Gas controller
         PV   - Power vent
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

[18] (x) Connection options
     FLxFL - Flange by flange
     MJxFL - Mechanical joint by flange
     MJxMJ - Mechanical joint by mechanical joint

Facility : Spindale, NC


Dielectric Unions[1] [LL]
   5DMG0
   5DMG1
   5DMG2
   5DMG3
   5DMG4
   5DMG5
   5DMG6
   5DMG7
   5DMG8
   5DMG9
   5DMH0
   5DMH1
   5DMH2
   5DMH3
   5DMH4
   5DMH5
   5DMH6
   LF3001A-(X)
   LF3002-(X)
   LF3003-(X)
   LF3004-(X)
   LF3005-(X)
   LF3005A-(X)
   LF3006-(X)
   LF3007-(X)
   LF3008-(X)
   LF3100-(X)
   LF3100M3
   LF3110-(X)
   LF3110-LF-(X)
   LF3200-(X)
   LF4001E-(X)

[1] -(X) Optional GB for High Temp models
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Irrigation and Trailer Regulator[2] [LL]
   LF(Z)560-(Y)-(VVV) - 0(XXX) 1/8" - 3/4"

[2] -(Y) Suffix:                               
           Blank - No Gage                       
           G     - Gage                  
    -(XXX) - Spring ranges 20 - 125 psi                
    (Z)    Suffix:                                
           H     - Hose end connection .75" only  
           Blank - NPT End Connection 1/8" and 1/4"
    -(VVV) Suffix:                             
           BSP   - British Thread End Connection 1/8" and 1/4"
           Blank - NPT End Connection 1/8" and 1/4"
    
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Valves [LL]
   1/4" - 3/8" LF215M1 (WW) (YY) (TT)[3]
   LFTWH-XX-YY-RV[4]

[3] -(WW) Adjusting bolt 
          Blank tee handle 
          X Slotted 
    -(YY) Special configurations 
          Z2 tee handle adjusting screw 
          Z9 teflon diaphragm protector 
    -(TT) Pressure range 
          0-8 
          0-20 
          0-50
[4] XX - Water Line Connection Type
         C     - Cold Water Valve
         FS    - Female Sweat
         FT    - Female Pipe Thread
         FT-ST - Female Pipe Thread with swivel tee connection
         H     - Hot Water Valve
         HC    - Hot and Cold Valve shipped in one box
         HCD   - Hot Valve (red handle), Recirc. Valve (orange handle) and Cold Valve 
                 (blue handle)
         PC    - Press Connection
         YY    - Valve Type
    Z - Label type
        ABC   - OEM Customer Labeled
        Blank - Watts labeled
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Facility : St Pauls, NC


Manifold[1] [LL]
   LFP-MF3BV 3/4" CF x 1/2" FTG
   LFP-MF4BV 3/4" CF x 1/2" FTG
   LFWPCM(w)-M(x)-(y)(z)
   LFWPCM1-M3-08B

[1] LFWPCM: Lead Free Water PEX Copper Manifold
    M(w) - Manifold end types configurations:(FS) - Female sweat, (MS) - Male sweat
           1 - Closed x swedged (FS)
           2 - Closed end x 3/4" crimp ring
           3 - 3/4" x 3/4" crimp ring
           4 - Open (MS) x swedged (FS)
           5 - Open (MS) x open (MS)
           6 - Open (MS) x open (MS) w/ base branch fittings
    M(x) - Number of outlets (3, 4, 6, 8, 10, 12, or 16)
    (y) - Outlet size
          06 - 3/8"
          08 - 1/2"
    (z) - Ball valves
          Blank - No ball valves
          B     - Ball valves
    Products may also have an optional CUST
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Strainer[2] [LL]
   (1)LF351(2)(3)(4)A 1/2" - 3"
   (1)LF352(2)(3)(4)A 1/2" - 3"
   (1)LF358(2)(3)(4)A 1/2" - 3"

[2] Can consist of any of the following:
    (1)	Prefix - Designating size				
        .25  - 1/4"			
        .375 - 3/8"			
        .50  - 1/2"			
        .75  - 3/4"			
        01.0 - 1"			
        01.25 - 1 1/4"			
        01.5 - 1 1/2"			
        02.0 - 2"			
        02.5 - 2 1/2"			
        03.0 - 3"
    (2) Buy America Act (BAA) compliance				
        Blank standard unit - US BAA compliant				
        -N Non - BAA qualified
    (3) Strainer screen construction options				
        Blank - Standard strainer screen - 20 Mesh up to 2" Size, 1/16" Perf 2-1/2" & 3", 
        304 SS only.				
        -5101 -  20 Mesh screen 				
        -5102 -  30 Mesh screen 				
        -5109 -  1/16" Perforated screen 				
        -5111 -  1/8" Perforated screen				
        -5105 -  0.033" Perforated screen				
        -5112 -  5/32" Perforated screen				
        -5141 -  5/32" Perf, 20 mesh lined				
        -5142 -  5/32" Perf, 30 mesh lined				
        -5143 -  5/32" Perf, 40 mesh lined				
        -5144 -  5/32" Perf, 60 mesh lined				
        -5145 -  5/32" Perf, 80 mesh lined				
        -5146 -  5/32" Perf, 100 mesh lined
        -5151 -  5/32" Perf, 300 mesh lined
    (4) Strainer screen material options				
        Blank - Standard Strainer Screen - (3) is Blank (standard) and material is 304 
        (standard).
        -08   -  304 Stainless steel screen material
        -04   -  316 Stainless steel screen material
        -05   - Monel screen material			
    - A - suffix for internal Use - Non-Standard Screen (no options).
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Facility : Plovdiv, Bulgaria


Gauges [LL]
   1/2 LFDPTG1-3 0-200
   1/2 LFDPTG1-3 0-50
   1/2 LFDPTG1-3 0-75
   1/2 LFDPTG1-3 0-75 Lowes
   1/2 LFDPTG3-2 1/2 0-200
   1/2 LFDPTG3-2 1/2 0-50
   1/2 LFDPTG3-2 1/2 0-75
   1/2 LFDPTG3-3 0-200
   1/2 LFDPTG3-3 0-50
   1/2 LFDPTG3-3 0-75
   1/2 LFDPTG3-3 0-75 Lowes
   1/2 LFTB-1 1/2-132-176
   1/2 LFTB-2 1/2-232-140
   1/2 LFTB-2 1/2-232-248
   1/2 LFTB-2 1/2-432-248
   1/2 LFTB-3-2-144
   1/2 LFTB-3-232-248
   1/2 LFTB-3-432-140
   1/2 LFTB-4-232-248
   1/2 LFTBR-3-232-248
   1/2 LFTBR-3-332-140
   1/4 LFDPTG3-2 1/20-75
   1/4 LFDPTG3A-2 1/20-75
   1/4 LFDPTG3A-30-75
   1/4 LFDPTG3L-2 1/20-75
   1/4 LFDPTG3L-30-75
   1/4-LFDPG1-X[1]
   1/4-LFDPG3-X[1]
   1/4-LFDPG5-X[1]
   1/8-LFDPG3-X[1]
   1/8-LFDPG5-X[1]

[1] X indicates size and may represent any of the following:
    1 1/2", 2", 2 1/2", 3" or 4"
    Pressure Ratings range from 0-15 PSI and 0-600 PSI
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Facility : Burlington, Ontario, Canada


Strainers[1] [LL]
   1/2 to 10" 77F-CSI
   1/2 to 2" 88CSI-SW
   1/2 to 2" 88CSI-T
   1/2 to 3" 87SI-SW
   1/2 to 3" 87SI-T
   1/2 to 6" 77F-CSSI
   2" 97FB-CSSIC
   2" to 12" 97FB-CIB
   2" to 12" 97FB-CSSIB

[1] 2 B  - Basket Style Strainer (default is Wye-pattern strainer)
    CI   - Cast Iron Body and Cover
    CSSI - Cast Stainless Steel Body and Cover
    F    - Flanged Connection
    SW   - Socket Weld Connection
    T    - Threaded Connection
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Facility : Qingdao, China


Strainers[LL]
   77F-DI-125 2" - 12"
   77F-DI-FDA-125 2" - 12"

[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Facility : Nogales, Sonara, Mexico


Backflow Preventer [LL]
   1/4" - 3/8" LFN9[1]
   1/4" - 3/8" LFN9C[1]
   3/4" - 3/8" LFNLF9[1]
   3/4" LF8
   3/4" LF8A
   3/4" LF8AC
   3/4" LF8B
   3/4" LF8BC
   3/4" LF8C
   3/4" LF8FR
   3/4" LFNF8
   3/8" LFCNLF9[1]
   LF07S 1"
   LF07S-U2-3 1 1/4" x 1 1/4"
   LF7 10-U2 1" X 1 1/4"
   LF7 3/8"x 3/8"
   LF7 U2-2 1 1/4" X 1 1/4"
   LF7-C 3/8" X 3/8"
   LFH7 3/4" x 3/4"
   LFH7-C 3/4" X 3/8"

[1] Optional Z8 (longer spring)
    Z9 Custom Product
    R-Can - Inlet and outlet adapters reversed
    HT - Hose thread connection"
    
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Test Cock[3] [LL]
   LFNPT-TC 0.125
   LFSAE-TC 0.125
   LFTC 1/4"
   SA TC 1/8 SAE LL
   SA-0.125 NPT-SAE19044
   SA-0.25 NPT19044
   SA-0125 NPT
   SA-TC-.125-NPT-LL 0.125
   SA-TC-.25-LL 1/4"
   SA-TC-.25-Z1-LL 1/4"
   SA-TC.125-SAE-LL 0.125

[3] This product is only authorized for use in the closed position.
    Products may bear the optional suffixe "-with Cap."		
    
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Vacuum Breaker[LL]
   LFN388
   LFN388-C
   LFN388-SC

[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Vacuum Breaker Relief[2] [LL]
   LF288A
   LF288A M2
   LF288A M4
   LF288AC
   LF288AC M4
   LF288ASC

[2] Sizes 1/4" - 3"
    C - Chrome
    SC - Stain chrome
    Models may have a Z# suffix which indicates custom.
    
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Facility : Gyeonggi-do, Republic of Korea


Shock Arrestor[LL]
   LF15M2-A
   LF15M2-AS
   LF15M2-B
   LF15M2-BS
   LF15M2-C
   LF15M2-CS
   LF15M2-D
   LF15M2-DS
   LF15M2-E
   LF15M2-ES
   LF15M2-F
   LF15M2-FS

[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Facility : Chang Hua, Taiwan


Check Stops[LL]
   LL230040 (1/2")
   LL230043 (1/2")
   LL230261 (3/4")
   LL230281 (1 1/4")

[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Valves[LL]
   LFWAM-W (1" FL X 3/4" IPS)
   LFWAM-W (3/4" FL X 3/4" IPS)
   LFWAMV (1" FL X 3/4" IPS)
   LFWAMV (3/4" FL X 3/4" IPS)

[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Facility : Changhua, Taiwan


Backflow Preventer[LL]
   3/4" LF8BI
   3/4" LF19-1
   3/4" LF8BI-C

[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Facility : Taichung City, Taiwan


Dielectric Unions[LL]
   LF301 1/2" - 2"
   LF302 1/2" - 1"
   LF305 1/2" - 3/4"

[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Facility : Taichung, Taiwan


Backflow Preventer[LL]
   0.75 8P
   0.75 8P-Z1
   0.75 8P-ZX

[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
     California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
     Act.

Number of matching Manufacturers is 1
Number of matching Products is 326
Processing time was 0 seconds