NSF/ANSI/CAN 372
Drinking Water System Components - Lead Content
| Powers, a Watts Regulator Co. Division | |
| 815 Chestnut Street | |
| North Andover, MA 01845 | |
| United States | |
| 978-688-1811 | |
Facility : Franklin, NH
Mixing Valve [LL]
|
| LFMM431-1[1] |
| LFMM431-2[1] |
| LFMM431-3[1] |
| LFMM431-4[1] |
| LFMM432-1[1] |
| LFMM432-2[1] |
| LFMM432-3[1] |
| LFMM432-4[1] |
| LFMM433-1[1] |
| LFMM433-2[1] |
| LFMM433-3[1] |
| LFMM433-4[1] |
| LFMM434-1[1] |
| LFMM434-2[1] |
| LFMM434-3[1] |
| LFMM434-4[1] |
| LFMM435-1[1] |
| LFMM435-2[1] |
| LFMM435-3[1] |
| LFMM435-4[1] |
| LFSH1432-1[1] |
| LFSH1432-11[1] |
| LFSH1432-2[1] |
| LFSH1432-3[1] |
| LFSH1432-31[1] |
| LFSH1432-4[1] |
| LFSH1434-1[1] |
| LFSH1434-13[1] |
| LFSH1434-2[1] |
| LFSH1434-3[1] |
| LFSH1434-33[1] |
| LFSH1434-4[1] |
| LFSH1435-1[1] |
| LFSH1435-15[1] |
| LFSH1435-2[1] |
| LFSH1435-3[1] |
| LFSH1435-35[1] |
| LFSH1435-4[1] |
[1] MM43*: This series is only available with check stops.
MM431-1 uses two 3/4" check stops. Considered a 3/4" valve because the outlet is 3/4".
MM432-1 uses two 3/4" check stops. Considered a 1" valve because the outlet is 1".
MM433-1 uses two 1-1/4" check stops. Considered a 1-1/4" valve because the outlet is
1-1/4".
MM434-1 uses two 1-1/4" check stops. Considered a 1-1/2" valve because the outlet is
1-1/2".
MM435-1 uses two 2" check stops. Considered a 2" valve because the outlet is 2".
SH143*: This series is only available with check stops.
SH1432-1 uses two 3/4" check stops. Considered a 1" valve because the outlet is 1"
(although some times listed as a 3/4 X 1 based on the inlet to outlet)
SH1434-1 uses two 1-1/4" check stops. Considered a 1-1/2" valve because the outlet is
1-1/2" (although some times listed as a 1-1/4 X 1-1/2 based on the inlet to outlet)
SH1435-1 uses two 2" check stops. Considered a 2" valve because the outlet is 2".
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
Act.
|
[2] (1) Finish
A - Rough brass
C - Chrome plated
(2) Piping inlet/outlet
D - Top/top
E - Bottom/top
F - Bottom/bottom
G - Bottom/side
(3) Cabinet style
M - Exposed
N - Stainless cabinet recessed
P - Stainless cabinet semi-recessed
Q - Stainless cabinet wall mount
R - Painted cabinet recessed
T - Painted cabinet semi-recessed
U - Painted cabinet wall mount
(4) Temperature
S - Standard (90°F - 160°F)
(5) Options
0 - None
2 - Cold water bypass
4 - T/P gauge on inlets
6 - Bypass and gauges
(6) Alarm
0 - None
(7) View port
0 - None
W - Window
Facility : St Pauls, NC
Supply Fixtures[1] [LL]
|
| LFLM490(1)-(2)-(3)-(4)-(5)-(6)-(7) |
| LFMM431(1)-(2)-(3)-(4)-(5)-(6)-(7) |
| LFMM431HL(1)-(2)-(3)-(4)-(5)-(6)-(7) |
| LFMM432(1)-(2)-(3)-(4)-(5)-(6)-(7) |
| LFMM432HL(1)-(2)-(3)-(4)-(5)-(6)-(7) |
| LFMM433(1)-(2)-(3)-(4)-(5)-(6)-(7) |
| LFMM433HL(1)-(2)-(3)-(4)-(5)-(6)-(7) |
| LFMM434(1)-(2)-(3)-(4)-(5)-(6)-(7) |
| LFMM434HL(1)-(2)-(3)-(4)-(5)-(6)-(7) |
| LFMM435(1)-(2)-(3)-(4)-(5)-(6)-(7) |
| LFMM435HL(1)-(2)-(3)-(4)-(5)-(6)-(7) |
| LFSH1432(1)-(2)-(3)-(4)-(5)-(6)-(7) |
| LFSH1432HL(1)-(2)-(3)-(6)-(7) |
| LFSH1434(1)-(2)-(3)-(4)-(5)-(6)-(7) |
| LFSH14346V(1)-(2)-(3)-(6)-(7) |
| LFSH1434DV(1)-(2)-(3)-(6)-(7) |
| LFSH1434HL(1)-(2)-(3)-(6)-(7) |
| LFSH1434QV(1)-(2)-(3)-(6)-(7) |
| LFSH1434TV(1)-(2)-(3)-(6)-(7) |
| LFSH1435(1)-(2)-(3)-(4)-(5)-(6)-(7) |
[1] (1) Finish
A - Rough brass
C - Chrome plated
(2) Piping inlet/outlet
D - Top/top
E - Bottom/top
F - Bottom/bottom
G - Bottom/side
(3) Cabinet style
M - Exposed
N - Stainless cabinet recessed
P - Stainless cabinet semi-recessed
Q - Stainless cabinet wall mount
R - Painted cabinet recessed
T - Painted cabinet semi-recessed
U - Painted cabinet wall mount
(4) Temperature
S - Standard (90°F - 160°F)
(5) Options
0 - None
2 - Cold water bypass
4 - T/P gauge on inlets
6 - Bypass and gauges
(6) Alarm
0 - None
(7) View port
0 – None
W - Window
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
Act.
|
Number of matching Manufacturers is 1
Number of matching Products is 58
Processing time was 0 seconds