NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, January 15, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/Lead_Content/Listings.asp?Standard=372%2DADD&Company=C0236488&
NSF/ANSI/CAN 372
Drinking Water System Components - Lead Content
Drinking Water System Components - Lead Content
| PINTURAS VILLADA SKC S.A. | |
| Ctra. Villalon 9-11 | |
| Villada/Palencia | |
| 34340 | |
| Spain | |
| 34 979 847 251 | |
| Visit this company's website |
Facility : Villada/Palencia, Spain
Coatings - Fittings[1] [LL] |
| Protecfull SFP 108 |
| Protecfull SFP 108 Repair Kit[2] |
[1] Colors: White, Blue
Number of Coats: 1-2
Maximum Field Use Dry Film Thickness (in mils): 600 microns (23.6 mils)
Re-coat Cure Time and Temperature: 3 days at 23°C
Final Cure Time and Temperature: 10 days at 23°C
Special Comments: Mix ratio of Part B:Part A (Polyol:Isocyanate) is 3:1 by volume.
Application by twin feed HOT airless spray at minimum 50ºC for each component.
[2] The Protecfull SFP 108 Repair Kit is only for use on areas coated with Protecfull SFP
108.
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
Act.
|
Coatings - Pump[1] [LL] |
| Protecfull SFP 108 |
[1] Colors: White, Blue
Number of Coats: 1-2
Maximum Field Use Dry Film Thickness (in mils): 600 microns (23.6 mils)
Re-coat Cure Time and Temperature: 3 days at 23°C
Final Cure Time and Temperature: 10 days at 23°C
Special Comments: Mix ratio of Part B:Part A (Polyol:Isocyanate) is 3:1 by volume.
Application by twin feed HOT airless spray at minimum 50ºC for each component.
[2] The Protecfull SFP 108 Repair Kit is only for use on areas coated with Protecfull SFP
108.
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
Act.
|
Coatings - Tank[1] [LL] |
| Protecfull SFP 108 |
[1] Colors: White, Blue
Number of Coats: 1-2
Maximum Field Use Dry Film Thickness (in mils): 600 microns (23.6 mils)
Re-coat Cure Time and Temperature: 3 days at 23°C
Final Cure Time and Temperature: 10 days at 23°C
Special Comments: Mix ratio of Part B:Part A (Polyol:Isocyanate) is 3:1 by volume.
Application by twin feed HOT airless spray at minimum 50ºC for each component.
[2] The Protecfull SFP 108 Repair Kit is only for use on areas coated with Protecfull SFP
108.
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
Act.
|
Coatings - Pipe[1] [LL] |
| Protecfull SFP 108 |
[1] Colors: White, Blue
Number of Coats: 1-2
Maximum Field Use Dry Film Thickness (in mils): 600 microns (23.6 mils)
Re-coat Cure Time and Temperature: 3 days at 23°C
Final Cure Time and Temperature: 10 days at 23°C
Special Comments: Mix ratio of Part B:Part A (Polyol:Isocyanate) is 3:1 by volume.
Application by twin feed HOT airless spray at minimum 50ºC for each component.
[2] The Protecfull SFP 108 Repair Kit is only for use on areas coated with Protecfull SFP
108.
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
Act.
|
Coatings - Valve[1] [LL] |
| Protecfull SFP 108 |
| Protecfull SFP 108 Repair Kit[2] |
[1] Colors: White, Blue
Number of Coats: 1-2
Maximum Field Use Dry Film Thickness (in mils): 600 microns (23.6 mils)
Re-coat Cure Time and Temperature: 3 days at 23°C
Final Cure Time and Temperature: 10 days at 23°C
Special Comments: Mix ratio of Part B:Part A (Polyol:Isocyanate) is 3:1 by volume.
Application by twin feed HOT airless spray at minimum 50ºC for each component.
[2] The Protecfull SFP 108 Repair Kit is only for use on areas coated with Protecfull SFP
108.
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
Act.
|
Coatings - Pipe[1] [LL] |
| Protecfull SFP 108 Repair Kit[2] |
[1] Colors: White, Blue
Number of Coats: 1-2
Maximum Field Use Dry Film Thickness (in mils): 600 microns (23.6 mils)
Re-coat Cure Time and Temperature: 3 days at 23°C
Final Cure Time and Temperature: 10 days at 23°C
Special Comments: Mix ratio of Part B:Part A (Polyol:Isocyanate) is 3:1 by volume.
Application by twin feed HOT airless spray at minimum 50ºC for each component.
[2] The Protecfull SFP 108 Repair Kit is only for use on areas coated with Protecfull SFP
108.
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
Act.
|
Coatings - Pump[1] [LL] |
| Protecfull SFP 108 Repair Kit[2] |
[1] Colors: White, Blue
Number of Coats: 1-2
Maximum Field Use Dry Film Thickness (in mils): 600 microns (23.6 mils)
Re-coat Cure Time and Temperature: 3 days at 23°C
Final Cure Time and Temperature: 10 days at 23°C
Special Comments: Mix ratio of Part B:Part A (Polyol:Isocyanate) is 3:1 by volume.
Application by twin feed HOT airless spray at minimum 50ºC for each component.
[2] The Protecfull SFP 108 Repair Kit is only for use on areas coated with Protecfull SFP
108.
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
Act.
|
Coatings - Tank[1] [LL] |
| Protecfull SFP 108 Repair Kit[2] |
[1] Colors: White, Blue
Number of Coats: 1-2
Maximum Field Use Dry Film Thickness (in mils): 600 microns (23.6 mils)
Re-coat Cure Time and Temperature: 3 days at 23°C
Final Cure Time and Temperature: 10 days at 23°C
Special Comments: Mix ratio of Part B:Part A (Polyol:Isocyanate) is 3:1 by volume.
Application by twin feed HOT airless spray at minimum 50ºC for each component.
[2] The Protecfull SFP 108 Repair Kit is only for use on areas coated with Protecfull SFP
108.
[LL] Product conforms with lead content requirements for “lead free” plumbing as defined by
California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water
Act.
|
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Number of matching Manufacturers is 1
Number of matching Products is 10
Processing time was 0 seconds