NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, January 15, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/Plumbing/Listings.asp?Company=03390&Standard=0MP&
MP
Mechanical Plumbing Products
Mechanical Plumbing Products
| Component Hardware Group, Inc. | |
| 6732 Shook Road | |
| Columbus, OH 43217 | |
| United States | |
| 800-526-3694 | |
| 732-363-4700 | |
| Visit this company's website |
Facility : Columbus, OH
| Product Type | Material Type | Trade Name | Product Standard | |||
Drains¢ § |
MLTPL |
Component Hardware Group, Inc. |
ASME A112.18.2/CSA B125.2 |
|||
| E18-1822 | ||||||
| E18-1822-GT | ||||||
| E18-1824 | ||||||
| E18-1840 | ||||||
| E38-1010 | ||||||
| E38-1010-BR | ||||||
| E38-1012 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Bed Pan Washers¢ § |
MLTPL |
Encore |
ASME A112.18.1/CSA B125.1 |
|||
| K79-4100-VB | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Valves¢ § |
MLTPL |
Encore |
ASME A112.18.1/CSA B125.1 |
|||
| KL24-Y002 Stop Valve, Cold+ [G] | ||||||
|
KL24-Y003 Stop Valve, Hot+ [G] |
||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Stainless Steel Sinks¢ § [2] [3] |
SS |
Encore |
ASME A112.19.3/CSA B45.4 |
|||
| FCA17D-101405B1 | ||||||
| FCA17D-10145-A | ||||||
| FCA17D-10145D0 | ||||||
| FCA17D-10145L0 | ||||||
| FCA17D-10145R0 | ||||||
| FCA17D-1410-05 | ||||||
| FCA17L-1014-10 | ||||||
| FCA17R-1014-10 | ||||||
| FCA18-090905B2 | ||||||
| FCA20-101405B0 | ||||||
| FCA20-101405B1 | ||||||
| FCA20-101405B2 | ||||||
| FCA20-101405D0 | ||||||
| FCA20-101405D1 | ||||||
| FCA20-101405D2 | ||||||
| FCA20-10145B23 | ||||||
| FCA20-12145B1S | ||||||
| FCAW-1614DADA | ||||||
| FCAW-162006B2 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[2] Sinks are certified with or without waste fittings.
[3] Products are in comlpinace with applicable sections of ICC/ANSI A117.1 accessible and
Usable Buildings and Facilities. Installation is per manufacturer's instructions and
the latest version of ICC/ANSI A117.1
|
||||||
Stainless Steel Sinks¢ § [3] |
SS |
Encore |
ASME A112.18.2/CSA B125.2 |
|||
| F3CS1-181812 | ||||||
| F3CS1-181812-D18 | ||||||
| F3CS1-181812-L18 | ||||||
| F3CS1-181812-R18 | ||||||
| F3CS1-242412 | ||||||
| F3CS1-242412-D24 | ||||||
| F3CS1-242412-L24 | ||||||
| F3CS1-242412-R24 | ||||||
| F3CS1-302412 | ||||||
| F3CS1-362412 | ||||||
| F3CS2-151512 | ||||||
| F3CS2-181812 | ||||||
| F3CS2-181812-D18 | ||||||
| F3CS2-181812-L18 | ||||||
| F3CS2-181812-R18 | ||||||
| F3CS2-242412 | ||||||
| F3CS2-242412-D24 | ||||||
| F3CS2-242412-L24 | ||||||
| F3CS2-242412-R24 | ||||||
| F3CS3-101410-D12 | ||||||
| F3CS3-121812 | ||||||
| F3CS3-121812-D18 | ||||||
| F3CS3-121812-L18 | ||||||
| F3CS3-121812-R18 | ||||||
| F3CS3-151512 | ||||||
| F3CS3-151512-D15 | ||||||
| F3CS3-151512-L15 | ||||||
| F3CS3-151512-R15 | ||||||
| F3CS3-181812 | ||||||
| F3CS3-181812-D18 | ||||||
| F3CS3-181812-D24 | ||||||
| F3CS3-181812-L18 | ||||||
| F3CS3-181812-L24 | ||||||
| F3CS3-181812-R18 | ||||||
| F3CS3-181812-R24 | ||||||
| F3CS3-182412 | ||||||
| F3CS3-182412-D18 | ||||||
| F3CS3-182412-D24 | ||||||
| F3CS3-182412-L18 | ||||||
| F3CS3-182412-L24 | ||||||
| F3CS3-182412-R18 | ||||||
| F3CS3-182412-R24 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[3] Products are in comlpinace with applicable sections of ICC/ANSI A117.1 accessible and
Usable Buildings and Facilities. Installation is per manufacturer's instructions and
the latest version of ICC/ANSI A117.1
|
||||||
Faucets+ ¢ § |
MLTPL |
Encore Series |
ASME A112.18.1/CSA B125.1 |
|||
| KEXX-XXXX-YYZ ELECTRONIC WIDE SPREAD FAUCETS+ ¢ § [8] [G] | ||||||
|
KL41-4XXX-YYY[1] [G] |
||||||
|
KL41-8XXX-YYY[1] [G] |
||||||
|
KL45-4XXX-YYY[1] [G] |
||||||
|
KL45-5000 |
||||||
| KL45-8XXX-YYY[1] [G] | ||||||
|
KL454XXXYYYGT[1] [G] |
||||||
|
KL454XXXYYYP[1] [G] |
||||||
|
KL50-9-857739 |
||||||
| KL50-9-857740 | ||||||
| KL50-9-857741 | ||||||
| KL52-9-857736 | ||||||
| KL52-9-857738 | ||||||
| KL65-9-857735 | ||||||
| KL65-9-857737 | ||||||
| KL85-Nx1x2x3-y1y2y3[G] | ||||||
|
KL86-NXXX-YYY[G] |
||||||
|
KL87-9005 |
||||||
| KL87-9105 | ||||||
| KL87-9105-CE1[G] | ||||||
|
KL87-9105-CE2[G] |
||||||
|
KL87-9105-CE4[G] |
||||||
|
KL87-9105-HE1[G] |
||||||
|
KL87-9105-HE2[G] |
||||||
|
KL87-9105-HE4[G] |
||||||
|
KL87-9205 |
||||||
| KPL83-Nx1x2x3-y1y2y3[G] | ||||||
|
KPL86-NXXX-YYY[G] |
||||||
|
KPV-X001 Pot Filler# * |
||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[8] KEXX-XXXX-YYZ
XX (#1 & #2) - numbers indicating faucet type
14 - Sink Outlet W/ "Y" Inlet Supply
15 - Sink Outlet W/ Manual Mixing Valve
16 - Sink Outlet W/ Thermostatic Valve
17 - Kitchen Faucet w/ "Y" Inlet Supply
18 - Kitchen Faucet w/ Manual Mixing Valve
19 - Kitchen Faucet w/ Thermostatic Mixing Valve
20 - Restroom Faucet w/ Manual Mixing Valve
21 - Restroom Faucet w/ Thermostatic Mixing Valve
22 - Restroom Faucet w/ "Y" Inlet Supply
23 - Nickel-Plated Restroom Faucet w/ Thermostatic Mixing Valve
24 - Nickel-Plated Restroom Faucet w/ Manual Mixing Valve
25 - Nickel-Plated Restroom Faucet w/ "Y" Inlet Supply Mixing Valve
81 - Nickel-Plated Restroom Faucet w/ Thermostatic Mixing Valve
X (#3) - number indicating cover plate configuration or letter indicating outlet design
1 - Wall Mount Kitchen w/o Cover Plate
2 - Wall Mount Kitchen w/ 4" Cover Plate
3 - Wall Mount Kitchen w/8" Cover Plate
4 - Deck Mount Kitchen or Restroom w/o Cover Plate
5 - Deck Mount Kitchen w/ 4" Cover Plate
6 - Deck Mount Kitchen w/ 8" Cover Plate
7 - Restroom Deck Mount w/o Cover Plate
8 - Restroom Deck Mount w/ 4" Cover Plate
9 - Restroom Deck Mount w/ 8" Cover Plate
B - EZ sink outlet design B
X (#4) - number indicating power supply
0 - DC or FDR Daisy Chain
1 - US 800 mA
2 - US 3A
3 - Int. 800 mA
4 - Int. 3A
XX (#5 & #6) - numbers indicating spout or body
00 - 3" Gooseneck
01 - 8" Gooseneck
02 - 6" Gooseneck
03 - 6" Gooseneck 10" High
05 - Cast Body
06 - 6" Spout
08 - 8" Spout
09 - 9" Spout
10 - 10" Spout
12 - 12" Spout
13 - 13'" Spout
14 - 14" Spout
16 - 16" Spout
18 - 18" Spout
31 - Sink outlet body design B
Y(#1) - letter indicating spout type
S - Swivel
R - Rigid
C - Cast Body
Y(#2) - letter indication aerator type
A - 0.5 GPM PCA Spray Vandal Resistant
B - 1.5 GPM Max Laminar Antimicrobial and Vandal Resistant
C - 0.5 GPM PCA Spray
D - 1.5 GPM Max Laminar Antimicrobial
E - 2.2 GPM Max Aerated Stream
F - 2.2 GPM Max Aerated Stream Vandal Resistant
M - 1.0 GPM PCA Laminar Antimicrobial
N - 1.0gpm laminar VR
O - 1.0gpm aerated stream VR
P - 1.5gpm aerated stream VR
Z - Number indicating program/electronic box configuration
0 - 20 Sec. & 30 Sec.
1 – 20 Sec. & 30 Sec., 2nd Gen. Compact Control Box
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
[1] Where X1X2X3-Y1Y2Y3 is as follows:
X1 - Valve type
X2X3 - Spout offset to 18"
Y1 - Spout style
Y2 - Aerator
Y3 - Handle
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
# Does not include 6.0GPM aerator. * Includes spouts up to 18" in length. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Faucet Components[G] |
MLTPL |
Encore Series |
ASME A112.18.1/CSA B125.1 |
|||
| KL19-X001 Wall Mount Body with Sensor Assembly | ||||||
| KL19-X002 Solenoid | ||||||
| KL19-X004 Deck Mount Body with Sensor Assembly | ||||||
| KL19-X025 Thermostatic Mixing Valve | ||||||
| KL19-X026 Thermostatic Mixing Valve | ||||||
| KL21-Y001 Deck Mount Body with Sensor Assembly | ||||||
| KL43-4050 | ||||||
| KL90-X015-M Manual Mixing Valve | ||||||
| KL90-X017-M "Y" Supply Inlet | ||||||
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Faucet Aerators+ ¢ § [G] |
MLTPL |
Encore Series |
ASME A112.18.1/CSA B125.1 |
|||
| KN50-X203-B 1.0gpm Laminar VR | ||||||
| KN50-X203-C 1.0 gpm AERATED STREAM VR | ||||||
| KN50-X203D 1.5 GPM AERATED STREAM VR | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Faucet Components+ ¢ § [G] |
MLTPL |
Encore Series |
ASME A112.18.1/CSA B125.1 |
|||
| KL-19-Y003 Deck Mount Body with Sensor Assembly | ||||||
| KL09-X001 Sink Outlet | ||||||
| KL19-Y004 Wall Mount Body with Sensor Assembly | ||||||
| KL21-Y002 Deck Mount Body with Sensor Assembly | ||||||
| KL50-0220-FS Encore Fan Spray | ||||||
| KL50-0220-FS-SS Encore Fans Spray (S/S Nozzle) | ||||||
| KL72-9000-LK | ||||||
| KL74-9003-RLK | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Faucet Components[G] |
MLTPL |
Encore Series |
ASSE 1070 |
|||
| KL19-X025 Thermostatic Mixing Valve | ||||||
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Faucet Components[G] |
MLTPL |
Encore Series |
ASME A112.1070 |
|||
| KL19-X026 Thermostatic Mixing Valve | ||||||
| KL19-X025 Thermostatic Mixing Valve | ||||||
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Faucet Components[G] |
MLTPL |
Encore Series |
ASSE 1070 |
|||
| KL19-X026 Thermostatic Mixing Valve | ||||||
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Vacuum Breakers+ ¢ § |
MLTPL |
CHG |
CSA B64.1.1 |
|||
| KL50-X137 Atmospheric Vacuum Breaker 3/8" NPT | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Faucet Components[G] |
MLTPL |
Encore Series |
CSA B125.70 |
|||
| KL19-X025 Thermostatic Mixing Valve | ||||||
| KL19-X026 Thermostatic Mixing Valve | ||||||
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Vacuum Breakers+ ¢ § |
MLTPL |
CHG |
CSA B64.1.1 |
|||
| KL50-X138 Atmospheric Vacuum Breaker 1/2" NPT | ||||||
| KL50-X138-S-SD S/S Vac Breaker 1/2"NPT-Severe Duty | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Faucets¢ § [4] [5] |
MLTPL |
Top Line Series |
ASME A112.18.1/CSA B125.1 |
|||
| TLL11-1XXX-YYYYY | ||||||
| TLL11-4XXX-YYYYY | ||||||
| TLL11-8XXX-YYYYY | ||||||
| TLL11-9XXX-YYYYY | ||||||
| TLL11-Y001-C | ||||||
| TLL11-Y001-CCV | ||||||
| TLL11-Y003-C | ||||||
| TLL11-Y003-CCV | ||||||
| TLL13-1XXX-YYYYY | ||||||
| TLL13-8XXX-YYYYY | ||||||
| TLL13-Y003-C | ||||||
| TLL13-Y003-CCV | ||||||
| TLL15-1XXX-YYYYY | ||||||
| TLL15-4XXX-YYYYY | ||||||
| TLL20-1XXX-YYYYY | ||||||
| TLL20-9XXX-YYYYY | ||||||
| TLL50-1XXX-YYYYY | ||||||
| TLL50-9XXX-YYYYY | ||||||
| TLL52-9XXX-YYYYY | ||||||
| TLL55-7xxx-yyyyyyyyy | ||||||
| TLL57-1XXX-YYYYY | ||||||
| TLL57-4XXX-YYYYY | ||||||
| TLL58-4XXX-YYYYY | ||||||
| TLL61-1XXX-YYYYY | ||||||
| TLL61-8XXX-YYYYY | ||||||
| TLL61-Y001-C | ||||||
| TLL62-8XXX-YYYYY | ||||||
| TLL65-9XXX-YYYYY | ||||||
| TLL70-1XXX-YYYYY | ||||||
| TLL70-9XXX-YYYYY | ||||||
| TTL15-Y001-C | ||||||
| TTL15-Y001-CCV | ||||||
| TTL20-Y003-C | ||||||
| TTL20-Y003-CCV | ||||||
| TTL50-Y001-C | ||||||
| TTL50-Y001-CCV | ||||||
| TTL57-Y001-C | ||||||
| TTL57-Y001-CCV | ||||||
| TTL61-Y001-CCV | ||||||
| TTL70-Y001-FL-C | ||||||
| TTL70-Y001-FL-CCV | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[4] The configuration for the Top-Line Faucet Model Series; TLL11 will follow the format
TLLxxNx1x2x3x4–y1y2y3y4y5 where:
(TLLxx) Body
TLL11 - CP POLISHED COVER / BRASS BODY 4” DECK MOUNT FAUCET
TLL11 - CP POLISHED COVER / BRASS BODY 8” DECK MOUNT FAUCET
(N) INLET
1 - PRE-RINSE
(x1) Body Type
4 - 4” DECK MOUNT FAUCET
8 - 8” DECK MOUNT FAUCET
(x2) VALVE
1 - 1/4 TURN CERAMIC W/ CHECK VALVE
(x3x4) SPOUT
00 - STANDARD (DEFAULT)
OR ALTERNATE WHEN REQUIRED “Nx1x2x3x4” - MINI
“–y1y2y3” or “YYYYY” - Note: Can include ANY combination(s) of the following:
BR – W/ WALL BRACKET
(BLANK) – W/O WALL BRACKET
AF1 – ADD-ON FAUCET W/6” SPOUT
AF2 – ADD-ON FAUCET W/8” SPOUT
AF3 – ADD-ON FAUCET W/10” SPOUT
AF4 – ADD-ON FAUCET W/12” SPOUT
AF5 – ADD-ON FAUCET W/14” SPOUT
AF6 – ADD-ON FAUCET W/16” SPOUT
AF7 – ADD-ON FAUCET W/18” SPOUT
MK – MOUNTING KIT
HF – CUSTOMER CODE
01 TO 99 – CUSTOMER CODE
AA TO ZZ – CUSTOMER CODE
• Alternate configuration for the Top-Line Pre-rinse Model Series TLL11 using Power
Pulse Spray Assembly will follow the format TLPxxNx1x2x3x4-y1y2y3y4y5 where:
(TLLxx) Body
XX - 11
(N) INLET
N - 1 (Pre-Rinse)
(x1) Body Type
4 - 4” DECK MOUNT FAUCET
8 - 8” DECK MOUNT FAUCET
(x2) VALVE
1 - 1/4 TURN CERAMIC W/ CHECK VALVE
(x3x4) SPOUT
x3x4 - 00 (Standard – Default)
L1 (.45 GPM Power Pulse spray)
L2 (.65 GPM Power Pulse spray)
L3 (.74 GPM Power Pulse spray)
L4 (1.05 GPM Power Pulse spray)
-yyy or yyyyy - Note: Can include ANY combination(s) of the following:
BR – w/ Wall Bracket
(Blank) – w/o Wall Bracket
AF1 – Add-on Faucet w/6” Spout
AF2 – Add-on Faucet w/8” Spout
AF3 – Add-on Faucet w/10” Spout
AF4 – Add-on Faucet w/12” Spout
AF5 – Add-on Faucet w/14” Spout
AF6 – Add-on Faucet w/16” Spout
AF7 – Add-on Faucet w/18” Spout
MK – Mounting Kit
HF – CUSTOMER CODE
01 TO 99 – CUSTOMER CODE
AA TO ZZ – CUSTOMER CODE
Configuration for the Top-Line Faucet Model Series; TLL13, TLL15, TLL20, TLL50, TLL52,
TLL57, TLL58, TLL61, TLL62, TLL65 and TLL70 will follow the format
TLLxx–Nx1x2x3–y1y2y3y4y5 where:
(TLLxx) Body
TLL11 - CP POLISHED COVER / BRASS BODY 4” DECK MOUNT FAUCET
TLL11 - CP POLISHED COVER / BRASS BODY 8” DECK MOUNT FAUCET
TLL13 - CP POLISHED BRASS 8” DECK MOUNT FAUCET
TLL15 - CP POLISHED COVER / BRASS BODY 4” WALL/BACKSPLASH MOUNT HAND SINK FAUCET
TLL20 - CP POLISHED BRASS SINGLE PANTRY FAUCET
TLL50 - CP POLISHED BRASS DOUBLE PANTRY FAUCET
TLL52 - CP POLISHED BRASS DOUBLE PANTRY FAUCET
TLL57 - CP POLISHED BRASS 4” DECK MOUNT FAUCET
TLL58 - CP POLISHED BRASS 4” DECK MOUNT FAUCET
TLL61 - CP POLISHED BRASS 8” DECK MOUNT FAUCET
TLL62 - CP POLISHED BRASS 8” DECK MOUNT FAUCET
TLL65 - CP POLISHED BRASS SINGLE PANTRY FAUCET
TLL70 - CP POLISHED BRASS SINGLE HOLE WALL MOUNT FAUCET
(N) INLET
4 - 4” CTR – CTR INLETS
8 - 8” CTR – CTR INLETS
9 - SINGLE HOLE MOUNT
(x1) VALVE
0 - FULL TURN COMPRESSION VALVE
1 - 1/4 TURN CERAMIC W/ CHECK VALVE
(x2x3) SPOUT
00 - 3” GOOSENECK
01 - 8” GOOSENECK
02 - 6” GOOSENECK
06 - 6” STRAIGHT SPOUT
08 - 8” STRAIGHT SPOUT
10 - 10” STRAIGHT SPOUT
12 - 12” STRAIGHT SPOUT
14 - 14” STRAIGHT SPOUT
16 - 16” STRAIGHT SPOUT
18 - 18” STRAIGHT SPOUT
20 - 20” STRAIGHT SPOUT
22 - 22” STRAIGHT SPOUT
24 - 24” STRAIGHT SPOUT
26 - 26” STRAIGHT SPOUT
28 - 28” STRAIGHT SPOUT
(y1) SPOUT STYLE
R - RIGID TUBULAR SPOUT
S - SWIVEL TUBULAR SPOUT
(y2) AERATOR
E - 2.2 GPM MAX AERATED STREAM
F - 2.2 GPM AERATED STREAM VANDAL RESISTANT
(y3) HANDLE
1 - STD LEVER W/ SANIGUARD
4 - 4” WRIST BLADE W/ SANIGUARD
5 - STD. LEVER (TAMPER-PROOF)
7 - 4” WRIST BLADE (TAMPER-PROOF)
[5] The configuration for the Top-Line Pre-rinse Model Series; TLL11, TLL13, TLL15, TLL20,
TLL50, TLL57, TLL61 and TLL70 will follow the format TLLxx–Nx1x2x3–y1y2y3y4y5 where:
(TLLxx) Body
TLL11 - CP POLISHED COVER / BRASS BODY 4” DECK MOUNT FAUCET
TLL11 - CP POLISHED COVER / BRASS BODY 8” DECK MOUNT FAUCET
TLL13 - CP POLISHED BRASS 8” DECK MOUNT FAUCET
TLL15 - CP POLISHED COVER / BRASS BODY 4” WALL/BACKSPLASH MOUNT HAND SINK FAUCET
TLL20 - CP POLISHED BRASS SINGLE PANTRY FAUCET
TLL50 - CP POLISHED BRASS DOUBLE PANTRY FAUCET
TLL57 - CP POLISHED BRASS 4” DECK MOUNT FAUCET
TLL61 - CP POLISHED BRASS 8” DECK MOUNT FAUCET
TLL70 - CP POLISHED BRASS SINGLE HOLE WALL MOUNT FAUCET
(N) INLET
1 - PRE-RINSE
(x1) VALVE
0 - FULL TURN COMPRESSION VALVE
1 - 1/4 TURN CERAMIC W/ CHECK VALVE
(x2x3) SPOUT
00 - STANDARD (DEFAULT)
OR ALTERNATE WHEN REQUIRED “Nx1x2x3” - MINI
“–y1y2y3” or “YYYYY” - BR – W/ WALL BRACKET
(BLANK) – W/O WALL BRACKET
AF1 – ADD-ON FAUCET W/6” SPOUT
AF2 – ADD-ON FAUCET W/8” SPOUT
AF3 – ADD-ON FAUCET W/10” SPOUT
AF4 – ADD-ON FAUCET W/12” SPOUT
AF5 – ADD-ON FAUCET W/14” SPOUT
AF6 – ADD-ON FAUCET W/16” SPOUT
AF7 – ADD-ON FAUCET W/18” SPOUT
MK – MOUNTING KIT
20 – 20” HOSE LENGTH
26 – 26” HOSE LENGTH
44 – 44” HOSE LENGTH
60 – 60” HOSE LENGTH
72 – 72” HOSE LENGTH
96 – 96” HOSE LENGTH
HF – CUSTOMER CODE
01 TO 99 – CUSTOMER CODE
• Pre-Rinse Assemblies using Power Pulse Spray Assembly will follow the format
TLPxx-Nx1x2x3-y1y2y3y4y5 where:
XX - 11, 13, 15, 20, 50, 57, 61, 70
N - 1 (Pre-Rinse)
x1 - 0 - (compression valve)
1 - 1/4 TURN CERAMIC W/ CHECK VALVE
x2x3 - 00 (Standard – Default)
L1 (.45 GPM Power Pulse spray)
L2 (.65 GPM Power Pulse spray)
L3 (.74 GPM Power Pulse spray)
L4 (1.05 GPM Power Pulse spray)
-yyy or yyyyy - BR – w/ Wall Bracket
(Blank) – w/o Wall Bracket
AF1 – Add-on Faucet w/6” Spout
AF2 – Add-on Faucet w/8” Spout
AF3 – Add-on Faucet w/10” Spout
AF4 – Add-on Faucet w/12” Spout
AF5 – Add-on Faucet w/14” Spout
AF6 – Add-on Faucet w/16” Spout
AF7 – Add-on Faucet w/18” Spout
MK – Mounting Kit
01 to 99 – Customer Code
|
||||||
Faucet Components¢ § |
MLTPL |
CHG |
ASME A112.18.1/CSA B125.1 |
|||
| KL40-0153 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Glass Fillers+ ¢ § [G] |
MLTPL |
CHG |
ASME A112.18.1/CSA B125.1 |
|||
| KL26-0010 Glass Filler Repair Kit | ||||||
| KL26-5000 | ||||||
| KL26-5000-SP2 | ||||||
| KL26-5001 | ||||||
| KL26-5012 | ||||||
| KL26-5012-SP | ||||||
| KL26-5014 | ||||||
| KL26-5015-SP | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Misc. Faucet Components+ ¢ § |
MLTPL |
CHG |
ASME A112.18.1/CSA B125.1 |
|||
| KL50-0220-FS-CEV ENCORE FAN SPRAY | ||||||
| KL50-Y002-FS-CEV PRE-RINSE FAN SPRAY VALVE ASSEMBL | ||||||
| KLP50-0220-12 Retro-fit Spray Valve Kit | ||||||
| KLP50-0220-65 Retro-fit Spray valve and Grip | ||||||
| KLP50-0220-65-CEV RETRO-FIT SPRAY VALVE AND GRIP | ||||||
| KLP50-0220-74 Retro-fit Spray Valve and Grip | ||||||
| KLP50-0220105 Retro-fit Spray Valve and Grip | ||||||
| KLP50-0220105-CEV RETRO-FIT SPRAY VALVE AND GRIP | ||||||
| KLP50-Y002-12 Pre-rinse Spray Valve Assembly | ||||||
| KLP50-Y002-65 Pre-rinse Spray Valve Assembly | ||||||
| KLP50-Y002-65-CEV PRE-RINSE SPRAY VALVE ASSEMBLY | ||||||
| KLP50-Y002-74 Pre-rinse Spray Valve Assembly | ||||||
| KLP50-Y002105 Pre-rinse Spray Valve Assembly | ||||||
| KLP50-Y002105-CEV PRE-RINSE SPRAY VALVE ASSEMBLY | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Vacuum Breakers+ ¢ § |
MLTPL |
CHG |
ASSE 1001 |
|||
| KL50-X137 Atmospheric Vacuum Breaker 3/8" NPT | ||||||
| KL50-X138 Atmospheric Vacuum Breaker 1/2" NPT | ||||||
| KL50-X138-S-SD S/S Vac Breaker 1/2"NPT-Severe Duty | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
$ XXX represents different spout lengths up to 18".
YYYY represents optional mounting kits, handles, or aerators.
[6] Product is a utility spray - not to be used as a pre-rinse spray valve.
[7] Knnn-X1X2X3X4-Y1Y2Y3
nnn - Faucet series
L41 - Encore deck mount faucet
L45 - Encore wall mount faucet
X1 – Inlet
4 - 4" c/c with 1/2" NPSM inlets
8 - 8" c/c with 1/2" NPSM inlets
X2 – Valve
0 - 1/4 Turn Standard Encore® Compression Valve
1 - 1/4 Turn Encore® Ceramic Valve
X3X4 – Spout
00 - 3 1/2" gooseneck spout
01 - 8 1/2" gooseneck spout
02 - 6" gooseneck spout
05 - 5" straight cast spout
06 - 6" straight spout
08 - 8" straight spout
09 - 9" tubular spout
10 - 10" straight spout
12 - 12" straight spout
13 - 13" double jointed spout
18 - 18" double jointed spout
50 - 6" spout 3/8" NPT x 2" riser
51 - 8" spout 3/8" NPT x 2" riser
52 - 12" spout 3/8" NPT x 2" riser
53 - 6" spout 3/8" NPT x 9" riser
54 - 8" spout 3/8" NPT x 9" riser
56 - 12" spout 3/8" NPT x 9" riser
“-“ – Universal Type Faucet Body (When Required)
U - 1/2" NPSM inlets with Straight Fittings
U - 1/2" NPSM inlets with Straight Fittings for KL41 Series
U - 1/2" NPSM inlets with 90° Swivel Spout Base & Elbow Fittings (for KL45
Series)
Y1 – Spout style
A - Swivel arched cast spout
B - Swivel bent riser tubular spout
C - Cast spout
D - Double jointed cast spout
G - Vacuum breaker w/ swivel riser & tubular spout 3/8" NPT outlet
K - Vacuum breaker w/ rigid riser & tubular spout 3/8" NPT outlet
R - Rigid tubular spout
S - Swivel tubular spout
T - Swivel cast spout
Y2 – Aerator
A - 0.5 GPM PCA spray vandal resistant
B - 1.5 GPM MAX laminar vandal resistant
C - 0.5 GPM PCA spray
D - 1.5 GPM MAX laminar
E - 2.2 GPM MAX aerated stream
F - 2.2 GPM MAX aerated stream vandal resistant
R - 3/8" threaded aerator (spout styles G and K only)
T - Serrated tip for hose (spout styles G and K only)
Y3 – Handle
1 - Standard Encore® lever
2 - Cross
4 - 4" wrist blade
5 - Standard lever w/ tamper proof screw
6 - 6" wrist blade
7 - 4" wrist blade w/ tamper proof screw
8 - 6" wrist blade w/ tamper proof screw
Facility : Zhejiang, China
| Product Type | Material Type | Trade Name | Product Standard | |||
Drains¢ § |
MLTPL |
Component Hardware Group, Inc. |
ASME A112.18.2/CSA B125.2 |
|||
| E18-1822-GT | ||||||
| E18-1840 | ||||||
| E18-1822 | ||||||
| E18-1824 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Bed Pan Washers¢ § |
MLTPL |
Encore |
ASME A112.18.1/CSA B125.1 |
|||
| K79-4100-VB | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Valves¢ § |
MLTPL |
Encore |
ASME A112.19.3/CSA B45.4 |
|||
| KL24-Y002 Stop Valve, Cold+ [G] | ||||||
|
KL24-Y003 Stop Valve, Hot+ [G] |
||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Stainless Steel Sinks¢ § [3] |
SS |
Encore |
ASME A112.19.3/CSA B45.4 |
|||
| F3CS1-181812 | ||||||
| F3CS3-182412-R24 | ||||||
| F3CS1-181812-L18 | ||||||
| F3CS1-181812-R18 | ||||||
| F3CS1-242412 | ||||||
| F3CS1-242412-D24 | ||||||
| F3CS1-242412-L24 | ||||||
| F3CS1-242412-R24 | ||||||
| F3CS1-302412 | ||||||
| F3CS1-362412 | ||||||
| F3CS2-151512 | ||||||
| F3CS2-181812 | ||||||
| F3CS2-181812-D18 | ||||||
| F3CS2-181812-L18 | ||||||
| F3CS2-181812-R18 | ||||||
| F3CS2-242412 | ||||||
| F3CS2-242412-D24 | ||||||
| F3CS2-242412-L24 | ||||||
| F3CS2-242412-R24 | ||||||
| F3CS3-101410-D12 | ||||||
| F3CS3-121812 | ||||||
| F3CS3-121812-D18 | ||||||
| F3CS3-121812-L18 | ||||||
| F3CS3-121812-R18 | ||||||
| F3CS3-151512 | ||||||
| F3CS3-151512-D15 | ||||||
| F3CS3-151512-L15 | ||||||
| F3CS3-151512-R15 | ||||||
| F3CS3-181812 | ||||||
| F3CS3-181812-D18 | ||||||
| F3CS3-181812-D24 | ||||||
| F3CS3-181812-L18 | ||||||
| F3CS3-181812-L24 | ||||||
| F3CS3-181812-R18 | ||||||
| F3CS3-181812-R24 | ||||||
| F3CS3-182412 | ||||||
| F3CS3-182412-D18 | ||||||
| F3CS3-182412-D24 | ||||||
| F3CS3-182412-L18 | ||||||
| F3CS3-182412-L24 | ||||||
| F3CS3-182412-R18 | ||||||
| F3CS1-181812-D18 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[3] Products are in comlpinace with applicable sections of ICC/ANSI A117.1 accessible and
Usable Buildings and Facilities. Installation is per manufacturer's instructions and the
latest version of ICC/ANSI A117.1
|
||||||
Stainless Steel Sinks¢ § [2] [3] |
SS |
Encore |
ASME A112.19.3/CSA B45.4 |
|||
| FCA17D-101405B1 | ||||||
| FCA20-12145B1S | ||||||
| FCA17D-10145D0 | ||||||
| FCA17D-10145L0 | ||||||
| FCA17D-10145R0 | ||||||
| FCA17D-1410-05 | ||||||
| FCA18-090905B2 | ||||||
| FCA20-101405B1 | ||||||
| FCA20-101405B2 | ||||||
| FCA20-101405D0 | ||||||
| FCA20-101405D1 | ||||||
| FCA20-101405D2 | ||||||
| FCA17R-1014-10 | ||||||
| FCA17L-1014-10 | ||||||
| FCA20-10145B23 | ||||||
| FCAW-1614DADA | ||||||
| FCAW-162006B2 | ||||||
| FCA20-101405B0 | ||||||
| FCA17D-10145-A | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[2] Sinks are certified with or without waste fittings.
[3] Products are in comlpinace with applicable sections of ICC/ANSI A117.1 accessible and
Usable Buildings and Facilities. Installation is per manufacturer's instructions and the
latest version of ICC/ANSI A117.1
|
||||||
Faucets+ ¢ § |
MLTPL |
Encore Series |
ASME A112.18.1/CSA B125.1 |
|||
| KN55 Encore Series# * | ||||||
|
KN57 Encore Series# * |
||||||
|
KN41-4XXX-YYYY Encore Deck Mt Fau 4" Center w/ Spt# $ |
||||||
|
KN41-8XXX-YYYY Encore Deck Mt Fau 8" Center w/ Spt# $ |
||||||
|
KN45-4XXX-YYYY Encore Deck Mt Fau 4" Center w/ Spt# $ |
||||||
|
KN45-8XXX-YYYY Encore Deck Mt Fau 8" Center w/ Spt# $ |
||||||
|
KN70 Single Wall Mount with KPV-X001 Pot Filler# * |
||||||
|
KN76 Single Wall/Wok Range w/ KPV-X001 Pot Filler# * |
||||||
|
KPV-X001 Pot Filler# * |
||||||
|
KL85-Nx1x2x3-y1y2y3[G] |
||||||
|
KPL83-Nx1x2x3-y1y2y3[G] |
||||||
|
KL86-NXXX-YYY[G] |
||||||
|
KPL86-NXXX-YYY[G] |
||||||
|
KL454XXXYYYP[1] [G] |
||||||
|
KL454XXXYYYGT[1] [G] |
||||||
|
KL45-8XXX-YYY[1] [G] |
||||||
|
KL45-4XXX-YYY[1] [G] |
||||||
|
KL41-8XXX-YYY[1] [G] |
||||||
|
KL41-4XXX-YYY[1] [G] |
||||||
|
KL87-9005 |
||||||
| KL87-9105 | ||||||
| KL87-9205 | ||||||
| KEXX-XXXX-YYZ ELECTRONIC WIDE SPREAD FAUCETS+ ¢ § [8] [G] | ||||||
|
KL87-9105-HE1[G] |
||||||
|
KL87-9105-CE2[G] |
||||||
|
KL87-9105-HE2[G] |
||||||
|
KL87-9105-CE4[G] |
||||||
|
KL87-9105-HE4[G] |
||||||
|
KL87-9105-CE1[G] |
||||||
|
KN51 Encore Series# * |
||||||
|
KN54 Encore Series# * |
||||||
|
KN61 Encore Series# * |
||||||
|
KN67 Encore Series# * |
||||||
|
KN70 Encore Series# * |
||||||
|
KN72 Encore Series# * |
||||||
|
KN74 Encore Series# * |
||||||
|
KN76 Encore Series# * |
||||||
|
KN64 Encore Series# * |
||||||
# Does not include 6.0GPM aerator. * Includes spouts up to 18" in length. # Does not include 6.0GPM aerator. $ XXX represents different spout lengths up to 18". YYYY represents optional mounting kits, handles, or aerators. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
[1] Where X1X2X3-Y1Y2Y3 is as follows:
X1 - Valve type
X2X3 - Spout offset to 18"
Y1 - Spout style
Y2 - Aerator
Y3 - Handle
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[8] KEXX-XXXX-YYZ
XX (#1 & #2) - numbers indicating faucet type
14 - Sink Outlet W/ "Y" Inlet Supply
15 - Sink Outlet W/ Manual Mixing Valve
16 - Sink Outlet W/ Thermostatic Valve
17 - Kitchen Faucet w/ "Y" Inlet Supply
18 - Kitchen Faucet w/ Manual Mixing Valve
19 - Kitchen Faucet w/ Thermostatic Mixing Valve
20 - Restroom Faucet w/ Manual Mixing Valve
21 - Restroom Faucet w/ Thermostatic Mixing Valve
22 - Restroom Faucet w/ "Y" Inlet Supply
23 - Nickel-Plated Restroom Faucet w/ Thermostatic Mixing Valve
24 - Nickel-Plated Restroom Faucet w/ Manual Mixing Valve
25 - Nickel-Plated Restroom Faucet w/ "Y" Inlet Supply Mixing Valve
81 - Nickel-Plated Restroom Faucet w/ Thermostatic Mixing Valve
X (#3) - number indicating cover plate configuration or letter indicating outlet
design
1 - Wall Mount Kitchen w/o Cover Plate
2 - Wall Mount Kitchen w/ 4" Cover Plate
3 - Wall Mount Kitchen w/8" Cover Plate
4 - Deck Mount Kitchen or Restroom w/o Cover Plate
5 - Deck Mount Kitchen w/ 4" Cover Plate
6 - Deck Mount Kitchen w/ 8" Cover Plate
7 - Restroom Deck Mount w/o Cover Plate
8 - Restroom Deck Mount w/ 4" Cover Plate
9 - Restroom Deck Mount w/ 8" Cover Plate
B - EZ sink outlet design B
X (#4) - number indicating power supply
0 - DC or FDR Daisy Chain
1 - US 800 mA
2 - US 3A
3 - Int. 800 mA
4 - Int. 3A
XX (#5 & #6) - numbers indicating spout or body
00 - 3" Gooseneck
01 - 8" Gooseneck
02 - 6" Gooseneck
03 - 6" Gooseneck 10" High
05 - Cast Body
06 - 6" Spout
08 - 8" Spout
09 - 9" Spout
10 - 10" Spout
12 - 12" Spout
13 - 13'" Spout
14 - 14" Spout
16 - 16" Spout
18 - 18" Spout
31 - Sink outlet body design B
Y(#1) - letter indicating spout type
S - Swivel
R - Rigid
C - Cast Body
Y(#2) - letter indication aerator type
A - 0.5 GPM PCA Spray Vandal Resistant
B - 1.5 GPM Max Laminar Antimicrobial and Vandal Resistant
C - 0.5 GPM PCA Spray
D - 1.5 GPM Max Laminar Antimicrobial
E - 2.2 GPM Max Aerated Stream
F - 2.2 GPM Max Aerated Stream Vandal Resistant
M - 1.0 GPM PCA Laminar Antimicrobial
N - 1.0gpm laminar VR
O - 1.0gpm aerated stream VR
P - 1.5gpm aerated stream VR
Z - Number indicating program/electronic box configuration
0 - 20 Sec. & 30 Sec.
1 – 20 Sec. & 30 Sec., 2nd Gen. Compact Control Box
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Faucet Components[G] |
MLTPL |
Encore Series |
ASME A112.18.1/CSA B125.1 |
|||
| KPV-X002 | ||||||
| KL43-4050 | ||||||
| KL21-Y001 Deck Mount Body with Sensor Assembly | ||||||
| KL19-X004 Deck Mount Body with Sensor Assembly | ||||||
| KL19-X002 Solenoid | ||||||
| KL19-X025 Thermostatic Mixing Valve | ||||||
| KL19-X026 Thermostatic Mixing Valve | ||||||
| KL90-X015-M Manual Mixing Valve | ||||||
| KL90-X017-M "Y" Supply Inlet | ||||||
| KL19-X001 Wall Mount Body with Sensor Assembly | ||||||
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Faucet Aerators+ ¢ § [G] |
MLTPL |
Encore Series |
ASME A112.18.1/CSA B125.1 |
|||
| KN50-X203-B 1.0gpm Laminar VR | ||||||
| KN50-X203D 1.5 GPM AERATED STREAM VR | ||||||
| KN50-X203-C 1.0 gpm AERATED STREAM VR | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Faucet Components+ ¢ § [G] |
MLTPL |
Encore Series |
ASME A112.18.1/CSA B125.1 |
|||
| KL19-Y004 Wall Mount Body with Sensor Assembly | ||||||
| KL-19-Y003 Deck Mount Body with Sensor Assembly | ||||||
| KL21-Y002 Deck Mount Boday with Sensor Assembly | ||||||
| KL09-X001 Sink Outlet | ||||||
| KL50-0220-FS-SS Encore Fans Spray (S/S Nozzle) | ||||||
| KLP50-0220-12 Retro-fit Spray Valve Kit | ||||||
| KLP50-Y002152 Pre-rinse Spray Valve Assembly | ||||||
| KLP50-0220152 Retro-fit Spray Valve Kit | ||||||
| KL50-0220-FS Encore Fan Spray | ||||||
| KLP50-Y002-12 Pre-rinse Spray Valve Assembly | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Faucet Components[G] |
MLTPL |
Encore Series |
ASSE 1070 |
|||
| KL19-X025 Thermostatic Mixing Valve | ||||||
| KL19-X026 Thermostatic Mixing Valve | ||||||
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Faucet Components[G] |
MLTPL |
Encore Series |
ASME A112.1070/CSA B125.70 |
|||
| KL19-X025 Thermostatic Mixing Valve | ||||||
| KL19-X026 Thermostatic Mixing Valve | ||||||
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Faucets¢ § [4] [5] |
MLTPL |
Top Line Series |
ASME A112.18.1/CSA B125.1 |
|||
| TLL13-Y003-CCV | ||||||
| TLL13-Y003-C | ||||||
| TTL15-Y001-CCV | ||||||
| TTL20-Y003-C | ||||||
| TTL20-Y003-CCV | ||||||
| TTL50-Y001-C | ||||||
| TTL50-Y001-CCV | ||||||
| TTL57-Y001-C | ||||||
| TTL57-Y001-CCV | ||||||
| TLL61-Y001-C | ||||||
| TTL61-Y001-CCV | ||||||
| TTL70-Y001-FL-C | ||||||
| TTL70-Y001-FL-CCV | ||||||
| TLL11-Y001-C | ||||||
| TLL11-Y001-CCV | ||||||
| TLL11-4XXX-YYYYY | ||||||
| TLL11-8XXX-YYYYY | ||||||
| TLL11-9XXX-YYYYY | ||||||
| TLL13-8XXX-YYYYY | ||||||
| TLL15-4XXX-YYYYY | ||||||
| TLL20-9XXX-YYYYY | ||||||
| TLL50-9XXX-YYYYY | ||||||
| TLL52-9XXX-YYYYY | ||||||
| TLL57-4XXX-YYYYY | ||||||
| TLL58-4XXX-YYYYY | ||||||
| TLL61-8XXX-YYYYY | ||||||
| TLL62-8XXX-YYYYY | ||||||
| TLL65-9XXX-YYYYY | ||||||
| TLL70-9XXX-YYYYY | ||||||
| TLL11-1XXX-YYYYY | ||||||
| TLL13-1XXX-YYYYY | ||||||
| TLL15-1XXX-YYYYY | ||||||
| TLL20-1XXX-YYYYY | ||||||
| TLL50-1XXX-YYYYY | ||||||
| TLL57-1XXX-YYYYY | ||||||
| TLL61-1XXX-YYYYY | ||||||
| TLL70-1XXX-YYYYY | ||||||
| TLL11-Y003-C | ||||||
| TLL11-Y003-CCV | ||||||
| TTL15-Y001-C | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[4] The configuration for the Top-Line Faucet Model Series; TLL11 will follow the format
TLLxxNx1x2x3x4–y1y2y3y4y5 where:
(TLLxx) Body
TLL11 - CP POLISHED COVER / BRASS BODY 4” DECK MOUNT FAUCET
TLL11 - CP POLISHED COVER / BRASS BODY 8” DECK MOUNT FAUCET
(N) INLET
1 - PRE-RINSE
(x1) Body Type
4 - 4” DECK MOUNT FAUCET
8 - 8” DECK MOUNT FAUCET
(x2) VALVE
1 - 1/4 TURN CERAMIC W/ CHECK VALVE
(x3x4) SPOUT
00 - STANDARD (DEFAULT)
OR ALTERNATE WHEN REQUIRED “Nx1x2x3x4” - MINI
“–y1y2y3” or “YYYYY” - Note: Can include ANY combination(s) of the following:
BR – W/ WALL BRACKET
(BLANK) – W/O WALL BRACKET
AF1 – ADD-ON FAUCET W/6” SPOUT
AF2 – ADD-ON FAUCET W/8” SPOUT
AF3 – ADD-ON FAUCET W/10” SPOUT
AF4 – ADD-ON FAUCET W/12” SPOUT
AF5 – ADD-ON FAUCET W/14” SPOUT
AF6 – ADD-ON FAUCET W/16” SPOUT
AF7 – ADD-ON FAUCET W/18” SPOUT
MK – MOUNTING KIT
HF – CUSTOMER CODE
01 TO 99 – CUSTOMER CODE
AA TO ZZ – CUSTOMER CODE
• Alternate configuration for the Top-Line Pre-rinse Model Series TLL11 using Power
Pulse Spray Assembly will follow the format TLPxxNx1x2x3x4-y1y2y3y4y5 where:
(TLLxx) Body
XX - 11
(N) INLET
N - 1 (Pre-Rinse)
(x1) Body Type
4 - 4” DECK MOUNT FAUCET
8 - 8” DECK MOUNT FAUCET
(x2) VALVE
1 - 1/4 TURN CERAMIC W/ CHECK VALVE
(x3x4) SPOUT
x3x4 - 00 (Standard – Default)
L1 (.45 GPM Power Pulse spray)
L2 (.65 GPM Power Pulse spray)
L3 (.74 GPM Power Pulse spray)
L4 (1.05 GPM Power Pulse spray)
-yyy or yyyyy - Note: Can include ANY combination(s) of the following:
BR – w/ Wall Bracket
(Blank) – w/o Wall Bracket
AF1 – Add-on Faucet w/6” Spout
AF2 – Add-on Faucet w/8” Spout
AF3 – Add-on Faucet w/10” Spout
AF4 – Add-on Faucet w/12” Spout
AF5 – Add-on Faucet w/14” Spout
AF6 – Add-on Faucet w/16” Spout
AF7 – Add-on Faucet w/18” Spout
MK – Mounting Kit
HF – CUSTOMER CODE
01 TO 99 – CUSTOMER CODE
AA TO ZZ – CUSTOMER CODE
Configuration for the Top-Line Faucet Model Series; TLL13, TLL15, TLL20, TLL50, TLL52,
TLL57, TLL58, TLL61, TLL62, TLL65 and TLL70 will follow the format
TLLxx–Nx1x2x3–y1y2y3y4y5 where:
(TLLxx) Body
TLL11 - CP POLISHED COVER / BRASS BODY 4” DECK MOUNT FAUCET
TLL11 - CP POLISHED COVER / BRASS BODY 8” DECK MOUNT FAUCET
TLL13 - CP POLISHED BRASS 8” DECK MOUNT FAUCET
TLL15 - CP POLISHED COVER / BRASS BODY 4” WALL/BACKSPLASH MOUNT HAND SINK FAUCET
TLL20 - CP POLISHED BRASS SINGLE PANTRY FAUCET
TLL50 - CP POLISHED BRASS DOUBLE PANTRY FAUCET
TLL52 - CP POLISHED BRASS DOUBLE PANTRY FAUCET
TLL57 - CP POLISHED BRASS 4” DECK MOUNT FAUCET
TLL58 - CP POLISHED BRASS 4” DECK MOUNT FAUCET
TLL61 - CP POLISHED BRASS 8” DECK MOUNT FAUCET
TLL62 - CP POLISHED BRASS 8” DECK MOUNT FAUCET
TLL65 - CP POLISHED BRASS SINGLE PANTRY FAUCET
TLL70 - CP POLISHED BRASS SINGLE HOLE WALL MOUNT FAUCET
(N) INLET
4 - 4” CTR – CTR INLETS
8 - 8” CTR – CTR INLETS
9 - SINGLE HOLE MOUNT
(x1) VALVE
0 - FULL TURN COMPRESSION VALVE
1 - 1/4 TURN CERAMIC W/ CHECK VALVE
(x2x3) SPOUT
00 - 3” GOOSENECK
01 - 8” GOOSENECK
02 - 6” GOOSENECK
06 - 6” STRAIGHT SPOUT
08 - 8” STRAIGHT SPOUT
10 - 10” STRAIGHT SPOUT
12 - 12” STRAIGHT SPOUT
14 - 14” STRAIGHT SPOUT
16 - 16” STRAIGHT SPOUT
18 - 18” STRAIGHT SPOUT
20 - 20” STRAIGHT SPOUT
22 - 22” STRAIGHT SPOUT
24 - 24” STRAIGHT SPOUT
26 - 26” STRAIGHT SPOUT
28 - 28” STRAIGHT SPOUT
(y1) SPOUT STYLE
R - RIGID TUBULAR SPOUT
S - SWIVEL TUBULAR SPOUT
(y2) AERATOR
E - 2.2 GPM MAX AERATED STREAM
F - 2.2 GPM AERATED STREAM VANDAL RESISTANT
(y3) HANDLE
1 - STD LEVER W/ SANIGUARD
4 - 4” WRIST BLADE W/ SANIGUARD
5 - STD. LEVER (TAMPER-PROOF)
7 - 4” WRIST BLADE (TAMPER-PROOF)
[5] The configuration for the Top-Line Pre-rinse Model Series; TLL11, TLL13, TLL15, TLL20,
TLL50, TLL57, TLL61 and TLL70 will follow the format TLLxx–Nx1x2x3–y1y2y3y4y5 where:
(TLLxx) Body
TLL11 - CP POLISHED COVER / BRASS BODY 4” DECK MOUNT FAUCET
TLL11 - CP POLISHED COVER / BRASS BODY 8” DECK MOUNT FAUCET
TLL13 - CP POLISHED BRASS 8” DECK MOUNT FAUCET
TLL15 - CP POLISHED COVER / BRASS BODY 4” WALL/BACKSPLASH MOUNT HAND SINK FAUCET
TLL20 - CP POLISHED BRASS SINGLE PANTRY FAUCET
TLL50 - CP POLISHED BRASS DOUBLE PANTRY FAUCET
TLL57 - CP POLISHED BRASS 4” DECK MOUNT FAUCET
TLL61 - CP POLISHED BRASS 8” DECK MOUNT FAUCET
TLL70 - CP POLISHED BRASS SINGLE HOLE WALL MOUNT FAUCET
(N) INLET
1 - PRE-RINSE
(x1) VALVE
0 - FULL TURN COMPRESSION VALVE
1 - 1/4 TURN CERAMIC W/ CHECK VALVE
(x2x3) SPOUT
00 - STANDARD (DEFAULT)
OR ALTERNATE WHEN REQUIRED “Nx1x2x3” - MINI
“–y1y2y3” or “YYYYY” - BR – W/ WALL BRACKET
(BLANK) – W/O WALL BRACKET
AF1 – ADD-ON FAUCET W/6” SPOUT
AF2 – ADD-ON FAUCET W/8” SPOUT
AF3 – ADD-ON FAUCET W/10” SPOUT
AF4 – ADD-ON FAUCET W/12” SPOUT
AF5 – ADD-ON FAUCET W/14” SPOUT
AF6 – ADD-ON FAUCET W/16” SPOUT
AF7 – ADD-ON FAUCET W/18” SPOUT
MK – MOUNTING KIT
20 – 20” HOSE LENGTH
26 – 26” HOSE LENGTH
44 – 44” HOSE LENGTH
60 – 60” HOSE LENGTH
72 – 72” HOSE LENGTH
96 – 96” HOSE LENGTH
HF – CUSTOMER CODE
01 TO 99 – CUSTOMER CODE
• Pre-Rinse Assemblies using Power Pulse Spray Assembly will follow the format
TLPxx-Nx1x2x3-y1y2y3y4y5 where:
XX - 11, 13, 15, 20, 50, 57, 61, 70
N - 1 (Pre-Rinse)
x1 - 0 - (compression valve)
1 - 1/4 TURN CERAMIC W/ CHECK VALVE
x2x3 - 00 (Standard – Default)
L1 (.45 GPM Power Pulse spray)
L2 (.65 GPM Power Pulse spray)
L3 (.74 GPM Power Pulse spray)
L4 (1.05 GPM Power Pulse spray)
-yyy or yyyyy - BR – w/ Wall Bracket
(Blank) – w/o Wall Bracket
AF1 – Add-on Faucet w/6” Spout
AF2 – Add-on Faucet w/8” Spout
AF3 – Add-on Faucet w/10” Spout
AF4 – Add-on Faucet w/12” Spout
AF5 – Add-on Faucet w/14” Spout
AF6 – Add-on Faucet w/16” Spout
AF7 – Add-on Faucet w/18” Spout
MK – Mounting Kit
01 to 99 – Customer Code
|
||||||
Faucet Components¢ § |
MLTPL |
CHG |
ASME A112.18.1/CSA B125.1 |
|||
| KL40-0153 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Glass Fillers+ ¢ § [G] |
MLTPL |
CHG |
ASME A112.18.1/CSA B125.1 |
|||
| KL26-5015-SP | ||||||
| KL26-0010 Glass Filler Repair Kit | ||||||
| KL26-5001 | ||||||
| KL26-5000 | ||||||
| KL26-5012 | ||||||
| KL26-5000-SP2 | ||||||
| KL26-5012-SP | ||||||
| KL26-5014 | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Vacuum Breakers+ ¢ § |
MLTPL |
CHG |
ASSE 1001 |
|||
| KL50-X137 Atmospheric Vacuum Breaker 3/8" NPT | ||||||
| KL50-X138 Atmospheric Vacuum Breaker 1/2" NPT | ||||||
| KL50-X138-S-SD S/S Vac Breaker 1/2"NPT-SevereDuty | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Vacuum Breakers+ ¢ § |
MLTPL |
CHG |
CSA B64.1.1 |
|||
| KL50-X137 Atmospheric Vacuum Breaker 3/8" NPT | ||||||
| KL50-X138 Atmospheric Vacuum Breaker 1/2" NPT | ||||||
| KL50-X138-S-SD S/S Vac Breaker 1/2"NPT-Severe Duty | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
[6] Utility spray not to be used as a pre-rinse spray valve.
[7] Knnn-X1X2X3X4-Y1Y2Y3
nnn - Faucet series
L41 - Encore deck mount faucet
L45 - Encore wall mount faucet
X1 – Inlet
4 - 4" c/c with 1/2" NPSM inlets
8 - 8" c/c with 1/2" NPSM inlets
X2 – Valve
0 - 1/4 Turn Standard Encore® Compression Valve
1 - 1/4 Turn Encore® Ceramic Valve
X3X4 – Spout
00 - 3 1/2" gooseneck spout
01 - 8 1/2" gooseneck spout
02 - 6" gooseneck spout
05 - 5" straight cast spout
06 - 6" straight spout
08 - 8" straight spout
09 - 9" tubular spout
10 - 10" straight spout
12 - 12" straight spout
13 - 13" double jointed spout
18 - 18" double jointed spout
50 - 6" spout 3/8" NPT x 2" riser
51 - 8" spout 3/8" NPT x 2" riser
52 - 12" spout 3/8" NPT x 2" riser
53 - 6" spout 3/8" NPT x 9" riser
54 - 8" spout 3/8" NPT x 9" riser
56 - 12" spout 3/8" NPT x 9" riser
"-" – Universal Type Faucet Body (When Required)
U - 1/2" NPSM inlets with Straight Fittings for KL41 Series
U - 1/2" NPSM inlets with 90° Swivel Spout Base & Elbow Fittings (for KL45
Series)
Y1 – Spout style
A - Swivel arched cast spout
B - Swivel bent riser tubular spout
C - Cast spout
D - Double jointed cast spout
G - Vacuum breaker w/ swivel riser & tubular spout 3/8" NPT outlet
K - Vacuum breaker w/ rigid riser & tubular spout 3/8" NPT outlet
R - Rigid tubular spout
S - Swivel tubular spout
T - Swivel cast spout
Y2 – Aerator
A - 0.5 GPM PCA spray vandal resistant
B - 1.5 GPM MAX laminar vandal resistant
C - 0.5 GPM PCA spray
D - 1.5 GPM MAX laminar
E - 2.2 GPM MAX aerated stream
F - 2.2 GPM MAX aerated stream vandal resistant
R - 3/8" threaded aerator (spout styles G and K only)
T - Serrated tip for hose (spout styles G and K only)
Y3 – Handle
1 - Standard Encore® lever
2 - Cross
4 - 4" wrist blade
5 - Standard lever w/ tamper proof screw
6 - 6" wrist blade
7 - 4" wrist blade w/ tamper proof screw
8 - 6" wrist blade w/ tamper proof screw
Number of matching Manufacturers is 1
Number of matching Products is 384