NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, July 17, 2025 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/Plumbing/Listings.asp?Company=21250&Standard=014&
NSF/ANSI 14
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
Georg Fischer LLC | |
9271 Jeronimo Road | |
Irvine, CA 92618 | |
United States | |
610-252-7355 | |
Visit this company's website |
Facility : Little Rock, AR
Corrosive Waste - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard | ||||
Pipe (CW)§ |
PP |
GSR or +GF+ FUSEAL |
ASTM F1412 |
||||
1 1/2" - 12" Sch 40 | |||||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Pipe (CW)§ |
PP |
GSR or +GF+ FUSEAL |
ASTM F1412 |
||||
1 1/2" - 12" Sch 40 | |||||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Pipe (CW)§ |
PP |
GSR or +GF+ FUSEAL |
ASTM F1412 |
||||
1 1/2" - 12" Sch 80 | |||||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Fittings (CW)§ |
PP |
GSR or +GF+ FUSEAL |
ASTM F1412 |
||||
Cleanout Tee with Plug (S x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Sanitary Tee |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
2" x 2" x 1 1/2" | 3" x 3" x 2" | 3" x 3" x 1 1/2" | 4" x 4" x 2" | ||||
4" x 4" x 3" | 6" x 6" x 4" | ||||||
Double Reducing Tee |
|||||||
3" x 3" x 2" x 2" | 2" x 2" x 1 1/2" x 1 1/2" | ||||||
Double Sanitary Tee |
|||||||
4" | 3" | 1 1/2" | 2" | ||||
1/4" Bend - Vent |
|||||||
1 1/2" | 2" | 3" | |||||
1/4" Bend - Short Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
1/4" Bend - Long Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
1/4" Bend - Spigot Short Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/6" Bend |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/8" Bend - Spg x S |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
1/8" Bend - S x S |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
1/16" Bend |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
3-Way Ell |
|||||||
1 1/2" | 2" | ||||||
45° Wye |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
45° Wye - Reducing |
|||||||
2" x 2" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 2" | 4" x 4" x 3" | ||||
6" x 6" x 2" | 6" x 6" x 3" | 6" x 6" x 4" | |||||
45° Wye - Double Reducing |
|||||||
2" x 2" x 1/2" x 1/2" | 3" x 3" x 2" x 2" | 3" x 3" x 1 1/2" x 1 1/2" | 4" x 4" x 2" x 2" | ||||
4" x 4" x 3" x 3" | 6" x 6" x 4" x 4" | ||||||
Long Turn Tee |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
2" x 2" x 1 1/2" | 3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 2" | ||||
4" x 4" x 3" | |||||||
Cleanout Adapter |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Male Adapter (MPT x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Female Adapter (FPT x S) |
|||||||
6" | 1 1/2" | 2" | 3" | ||||
4" | |||||||
Unions |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Union Nut Adapter - S |
|||||||
1 1/2" | 2" | ||||||
Union Nut Adapter - Spg |
|||||||
1 1/2" | |||||||
Male Union Adapter - S |
|||||||
1 1/2" | |||||||
Male Union Adapter - Spg |
|||||||
2" | |||||||
Male Union Adapter - FPT |
|||||||
2" | |||||||
Male Union Adapter - MPT |
|||||||
2" | |||||||
Coupling |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Pipe Increaser |
|||||||
1 1/2" x 2" | 2" x 3" | 2" x 4" | 3" x 4" | ||||
Reducer Bushing (Spg x S) |
|||||||
2" x 1 1/2" | 3" x 1 1/2" | 3" x 2" | 4" x 2" | ||||
4" x 3" | 6" x 4" | ||||||
Plug |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
P-Trap - With Cleanout |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
P-Trap - Without Cleanout |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
P-Trap - Union |
|||||||
1 1/2" | 2" | ||||||
P-Trap - Slip Joint Inlet |
|||||||
1 1/2" | |||||||
Strainer Adapter |
|||||||
1 1/2" | |||||||
Swivel Strainer Adapter |
|||||||
1 1/2" | 1 1/2" x 12L | ||||||
Cap |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Flange |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Pipe (CW)¢ § |
PP |
GSR or +GF+ FUSEAL |
CSA B181.3 |
||||
1 1/2" - 12" F8004-XXXX Sch 40 | |||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Pipe (CW)¢ § |
PP |
GSR or +GF+ FUSEAL |
CSA B181.3 |
||||
1 1/2" - 12" P8004-XXX Sch 40 | |||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Pipe (CW)¢ § |
PP |
GSR or +GF+ FUSEAL |
CSA B181.3 |
||||
1 1/2" - 12" F8008-XXX Sch 80 | |||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Pipe (CW)¢ § |
PP |
GSR or +GF+ FUSEAL |
CSA B181.3 |
||||
1 1/2" - 12" R8008-XXX Sch 80 | |||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Fittings (CW)¢ § |
PP |
GSR or +GF+ FUSEAL |
CSA B181.3 |
||||
1/16" Bend |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Long Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
1/4" Bend - Short Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
1/4" Bend - Spigot Short Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Vent |
|||||||
1 1/2" | 2" | 3" | |||||
1/6" Bend |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/8" Bend - S x S |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
1/8" Bend - Spg x S |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
3-Way Ell |
|||||||
1 1/2" | 2" | ||||||
45° Wye |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
45° Wye - Double Reducing |
|||||||
4" x 4" x 3" x 3" | 3" x 3" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | 4" x 4" x 2" x 2" | ||||
2" x 2" x 1 1/2" x 1 1/2" | 6" x 6" x 4" x 4" | ||||||
45° Wye - Reducing |
|||||||
2" x 2" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 2" | 4" x 4" x 3" | ||||
6" x 6" x 2" | 6" x 6" x 3" | 6" x 6" x 4" | |||||
Cap |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Cleanout Adapter |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Cleanout Tee with Plug (S x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Coupling |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Double Reducing Tee |
|||||||
2" x 2" x 1 1/2" x 1 1/2" | |||||||
Double Sanitary Tee |
|||||||
1 1/2" | 2" | 3" | |||||
Female Adapter (FPT x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Flange |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Long Turn Tee |
|||||||
1 1/2" | 2" | 2" x 2" x 1 1/2" | 3" | ||||
3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" | 4" x 4" x 2" | ||||
4" x 4" x 3" | |||||||
Male Adapter (MPT x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Male Union Adapter - FPT |
|||||||
2" | |||||||
Male Union Adapter - MPT |
|||||||
2" | |||||||
Male Union Adapter - S |
|||||||
1 1/2" | |||||||
Male Union Adapter - Spg |
|||||||
2" | |||||||
P-Trap - Slip Joint Inlet |
|||||||
1 1/2" | |||||||
P-Trap - Union |
|||||||
1 1/2" | 2" | ||||||
P-Trap - With Cleanout |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
P-Trap - Without Cleanout |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Pipe Increaser |
|||||||
1 1/2" x 2" | 2" x 3" | 2" x 4" | 3" x 4" | ||||
Plug |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Reducer Bushing (Spg x S) |
|||||||
2" x 1 1/2" | 3" x 1 1/2" | 3" x 2" | 4" x 2" | ||||
4" x 3" | 6" x 4" | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Fittings (CW)§ |
PP |
GSR or +GF+ FUSEAL FAST LOCK |
ASTM F1412 |
||||
1/16" Bend |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Long Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Short Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Spigot Short Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Vent |
|||||||
1 1/2" | 2" | 3" | |||||
1/6" Bend |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/8" Bend - S x S |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/8" Bend - Spg x S |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
3-Way Ell |
|||||||
1 1/2" | 2" | ||||||
45° Wye |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
45° Wye - Double Reducing |
|||||||
2" x 2" x 1/2" x 1/2" | 3" x 3" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | 4" x 4" x 2" x 2" | ||||
4" x 4" x 3" x 3" | |||||||
45° Wye - Reducing |
|||||||
2" x 2" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 2" | 4" x 4" x 3" | ||||
Cap |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Cleanout Adapter |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Cleanout Tee with Plug (S x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Coupling |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Double Reducing Tee |
|||||||
2" x 2" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | ||||||
Double Sanitary Tee |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Female Adapter (FPT x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Flange |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Long Turn Tee |
|||||||
1 1/2" | 2" | 2" x 2" x 1 1/2" | 3" | ||||
3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" | 4" x 4" x 2" | ||||
4" x 4" x 3" | |||||||
Male Adapter (MPT x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Male Union Adapter - FPT |
|||||||
2" | |||||||
Male Union Adapter - MPT |
|||||||
2" | |||||||
Male Union Adapter - S |
|||||||
1 1/2" | |||||||
Male Union Adapter - Spg |
|||||||
2" | |||||||
P-Trap - Slip Joint Inlet |
|||||||
1 1/2" | |||||||
P-Trap - Union |
|||||||
1 1/2" | 2" | ||||||
P-Trap - With Cleanout |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
P-Trap - Without Cleanout |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Pipe Increaser |
|||||||
1 1/2" x 2" | 2" x 3" | 2" x 4" | 3" x 4" | ||||
Plug |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Reducer Bushing (Spg x S) |
|||||||
2" x 1 1/2" | 3" x 1 1/2" | 3" x 2" | 4" x 2" | ||||
4" x 3" | 6" x 4" | ||||||
Sanitary Tee |
|||||||
1 1/2" | 2" | 2" x 2" x 1 1/2" | 3" | ||||
3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" | 4" x 4" x 2" | ||||
4" x 4" x 3" | |||||||
Strainer Adapter |
|||||||
1 1/2" | |||||||
Swivel Strainer Adapter |
|||||||
1 1/2" | 1 1/2" x 12L | ||||||
Union Nut Adapter - S |
|||||||
1 1/2" | 2" | ||||||
Union Nut Adapter - Spg |
|||||||
1 1/2" | |||||||
Unions |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Fittings (CW)¢ § |
PP |
GSR or +GF+ FUSEAL FAST LOCK |
CSA B181.3 |
||||
1/16" Bend |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Long Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Short Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Spigot Short Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Vent |
|||||||
1 1/2" | 2" | 3" | |||||
1/6" Bend |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/8" Bend - S x S |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/8" Bend - Spg x S |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
3-Way Ell |
|||||||
1 1/2" | 2" | ||||||
45° Wye |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
45° Wye - Double Reducing |
|||||||
2" x 2" x 1/2" x 1/2" | 3" x 3" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | 4" x 4" x 2" x 2" | ||||
4" x 4" x 3" x 3" | |||||||
45° Wye - Reducing |
|||||||
2" x 2" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 2" | 4" x 4" x 3" | ||||
Cap |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Cleanout Adapter |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Cleanout Tee with Plug (S x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Coupling |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Double Reducing Tee |
|||||||
2" x 2" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | ||||||
Double Sanitary Tee |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Female Adapter (FPT x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Flange |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Long Turn Tee |
|||||||
1 1/2" | 2" | 2" x 2" x 1 1/2" | 3" | ||||
3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" | 4" x 4" x 2" | ||||
4" x 4" x 3" | |||||||
Male Adapter (MPT x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Male Union Adapter - FPT |
|||||||
2" | |||||||
Male Union Adapter - MPT |
|||||||
2" | |||||||
Male Union Adapter - S |
|||||||
1 1/2" | |||||||
Male Union Adapter - Spg |
|||||||
2" | |||||||
P-Trap - Slip Joint Inlet |
|||||||
1 1/2" | |||||||
P-Trap - Union |
|||||||
1 1/2" | 2" | ||||||
P-Trap - With Cleanout |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
P-Trap - Without Cleanout |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Pipe Increaser |
|||||||
1 1/2" x 2" | 2" x 3" | 2" x 4" | 3" x 4" | ||||
Plug |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Reducer Bushing (Spg x S) |
|||||||
2" x 1 1/2" | 3" x 1 1/2" | 3" x 2" | 4" x 2" | ||||
4" x 3" | 6" x 4" | ||||||
Sanitary Tee |
|||||||
1 1/2" | 2" | 2" x 2" x 1 1/2" | 3" | ||||
3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" | 4" x 4" x 2" | ||||
4" x 4" x 3" | |||||||
Strainer Adapter |
|||||||
1 1/2" | |||||||
Swivel Strainer Adapter |
|||||||
1 1/2" | 1 1/2" x 12L | ||||||
Union Nut Adapter - S |
|||||||
1 1/2" | 2" | ||||||
Union Nut Adapter - Spg |
|||||||
1 1/2" | |||||||
Unions |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Fittings (CW)§ |
PP |
GSR or +GF+ Seadrain |
ASTM F1412 |
||||
Male Adapter (MPT x S) |
|||||||
4" | |||||||
Male Union Adapter - FPT |
|||||||
2" | |||||||
Male Union Adapter - MPT |
|||||||
2" | |||||||
Male Union Adapter - S |
|||||||
1 1/2" | |||||||
Male Union Adapter - Spg |
|||||||
2" | |||||||
P-Trap - Slip Joint Inlet |
|||||||
1 1/2" | |||||||
P-Trap - Union |
|||||||
1 1/2" | |||||||
P-Trap - With Cleanout |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
P-Trap - Without Cleanout |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Pipe Increaser |
|||||||
1 1/2" x 2" | 2" x 3" | 2" x 4" | 3" x 4" | ||||
Plug |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Vent |
|||||||
3" | |||||||
1/6" Bend |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/8" Bend - S x S |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
1/8" Bend - Spg x S |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
3-Way Ell |
|||||||
1 1/2" | 2" | ||||||
45° Wye |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
45° Wye - Double Reducing |
|||||||
2" x 2" x 1/2" x 1/2" | 3" x 3" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | 4" x 4" x 2" x 2" | ||||
4" x 4" x 3" x 3" | 6" x 6" x 4" x 4" | ||||||
45° Wye - Reducing |
|||||||
2" x 2" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 2" | 4" x 4" x 3" | ||||
6" x 6" x 2" | 6" x 6" x 3" | 6" x 6" x 4" | |||||
Cap |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Cleanout Adapter |
|||||||
1 1/2" | |||||||
Unions |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Female Adapter (FPT x S) |
|||||||
4" | 6" | ||||||
Flange |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Long Turn Tee |
|||||||
1 1/2" | 2" | 2" x 2" x 1 1/2" | 3" | ||||
3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" | 4" x 4" x 2" | ||||
4" x 4" x 3" | |||||||
Male Adapter (MPT x S) |
|||||||
1 1/2" | 2" | 3" | |||||
Cleanout Adapter |
|||||||
2" | 3" | 4" | 6" | ||||
Cleanout Tee with Plug (S x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Coupling |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Double Reducing Tee |
|||||||
2" x 2" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | ||||||
Double Sanitary Tee |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Female Adapter (FPT x S) |
|||||||
1 1/2" | 2" | 3" | |||||
1/4" Bend - Long Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
1/4" Bend - Short Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
1/4" Bend - Spigot Short Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Vent |
|||||||
1 1/2" | |||||||
Reducer Bushing (Spg x S) |
|||||||
2" x 1 1/2" | 3" x 1 1/2" | 3" x 2" | 4" x 2" | ||||
4" x 3" | 6" x 4" | ||||||
Sanitary Tee |
|||||||
1 1/2" | 2" | 2" x 2" x 1 1/2" | 3" | ||||
3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" | 4" x 4" x 2" | ||||
4" x 4" x 3" | 6" x 6" x 4" | ||||||
Strainer Adapter |
|||||||
1 1/2" | |||||||
Swivel Strainer Adapter |
|||||||
1 1/2" | 1 1/2" x 12L | ||||||
Union Nut Adapter - S |
|||||||
1 1/2" | 2" | ||||||
Union Nut Adapter - Spg |
|||||||
1 1/2" | |||||||
1/4" Bend - Vent |
|||||||
2" | |||||||
1/16" Bend |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Fittings (CW)¢ § |
PP |
GSR or +GF+ Seadrain |
CSA B181.3 |
||||
Plug |
|||||||
3" | 4" | ||||||
Reducer Bushing (Spg x S) |
|||||||
2" x 1 1/2" | 3" x 1 1/2" | 3" x 2" | 4" x 2" | ||||
4" x 3" | 6" x 4" | ||||||
Sanitary Tee |
|||||||
1 1/2" | 2" | 2" x 2" x 1 1/2" | 3" | ||||
3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" | 4" x 4" x 2" | ||||
4" x 4" x 3" | 6" x 6" x 4" | ||||||
Strainer Adapter |
|||||||
1 1/2" | |||||||
Swivel Strainer Adapter |
|||||||
1 1/2" | 1 1/2" x 12L | ||||||
Union Nut Adapter - S |
|||||||
1 1/2" | 2" | ||||||
Union Nut Adapter - Spg |
|||||||
1 1/2" | |||||||
Unions |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Cleanout Adapter |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Cleanout Tee with Plug (S x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Coupling |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Double Reducing Tee |
|||||||
2" x 2" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | ||||||
Double Sanitary Tee |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Female Adapter (FPT x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Flange |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Long Turn Tee |
|||||||
1 1/2" | 2" | 2" x 2" x 1 1/2" | 3" | ||||
3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" | 4" x 4" x 2" | ||||
4" x 4" x 3" | |||||||
Male Adapter (MPT x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Male Union Adapter - FPT |
|||||||
2" | |||||||
Male Union Adapter - MPT |
|||||||
2" | |||||||
Male Union Adapter - S |
|||||||
1 1/2" | |||||||
Male Union Adapter - Spg |
|||||||
2" | |||||||
P-Trap - Slip Joint Inlet |
|||||||
1 1/2" | |||||||
P-Trap - Union |
|||||||
1 1/2" | 2" | ||||||
P-Trap - With Cleanout |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
P-Trap - Without Cleanout |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Pipe Increaser |
|||||||
1 1/2" x 2" | 2" x 3" | 2" x 4" | 3" x 4" | ||||
Plug |
|||||||
1 1/2" | 2" | ||||||
1/16" Bend |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Long Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
1/4" Bend - Short Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
1/4" Bend - Spigot Short Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Vent |
|||||||
1 1/2" | 2" | 3" | |||||
1/6" Bend |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/8" Bend - S x S |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
1/8" Bend - Spg x S |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
3-Way Ell |
|||||||
1 1/2" | 2" | ||||||
45° Wye |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
45° Wye - Double Reducing |
|||||||
2" x 2" x 1/2" x 1/2" | 3" x 3" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | 4" x 4" x 2" x 2" | ||||
4" x 4" x 3" x 3" | 6" x 6" x 4" x 4" | ||||||
45° Wye - Reducing |
|||||||
2" x 2" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 2" | 4" x 4" x 3" | ||||
6" x 6" x 2" | 6" x 6" x 3" | 6" x 6" x 4" | |||||
Cap |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Fittings (CW)§ |
PP |
GSR or +GF+ Sea Drain FAST LOCK |
ASTM F1412 |
||||
1/16" Bend |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Long Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Short Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Spigot Short Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Vent |
|||||||
1 1/2" | 2" | 3" | |||||
1/6" Bend |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/8" Bend - S x S |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/8" Bend - Spg x S |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
3-Way Ell |
|||||||
1 1/2" | 2" | ||||||
45° Wye |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
45° Wye - Double Reducing |
|||||||
2" x 2" x 1/2" x 1/2" | 3" x 3" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | 4" x 4" x 2" x 2" | ||||
4" x 4" x 3" x 3" | |||||||
45° Wye - Reducing |
|||||||
2" x 2" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 2" | 4" x 4" x 3" | ||||
Cap |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Cleanout Adapter |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Cleanout Tee with Plug (S x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Coupling |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Double Reducing Tee |
|||||||
2" x 2" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | ||||||
Double Sanitary Tee |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Female Adapter (FPT x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Flange |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Long Turn Tee |
|||||||
1 1/2" | 2" | 2" x 2" x 1 1/2" | 3" | ||||
3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" | 4" x 4" x 2" | ||||
4" x 4" x 3" | |||||||
Male Adapter (MPT x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Male Union Adapter - FPT |
|||||||
2" | |||||||
Male Union Adapter - MPT |
|||||||
2" | |||||||
Male Union Adapter - S |
|||||||
1 1/2" | |||||||
Male Union Adapter - Spg |
|||||||
2" | |||||||
P-Trap - Slip Joint Inlet |
|||||||
1 1/2" | |||||||
P-Trap - Union |
|||||||
1 1/2" | 2" | ||||||
P-Trap - With Cleanout |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
P-Trap - Without Cleanout |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Pipe Increaser |
|||||||
1 1/2" x 2" | 2" x 3" | 2" x 4" | 3" x 4" | ||||
Plug |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Reducer Bushing (Spg x S) |
|||||||
2" x 1 1/2" | 3" x 1 1/2" | 3" x 2" | 4" x 2" | ||||
4" x 3" | 6" x 4" | ||||||
Sanitary Tee |
|||||||
1 1/2" | 2" | 2" x 2" x 1 1/2" | 3" | ||||
3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" | 4" x 4" x 2" | ||||
4" x 4" x 3" | |||||||
Strainer Adapter |
|||||||
1 1/2" | |||||||
Swivel Strainer Adapter |
|||||||
1 1/2" | 1 1/2" x 12L | ||||||
Union Nut Adapter - S |
|||||||
1 1/2" | 2" | ||||||
Union Nut Adapter - Spg |
|||||||
1 1/2" | |||||||
Unions |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Fittings (CW)¢ § |
PP |
GSR or +GF+ Sea Drain FAST LOCK |
CSA B181.3 |
||||
1/16" Bend |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Long Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Short Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Spigot Short Sweep |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Vent |
|||||||
1 1/2" | 2" | 3" | |||||
1/6" Bend |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/8" Bend - S x S |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/8" Bend - Spg x S |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
3-Way Ell |
|||||||
1 1/2" | 2" | ||||||
45° Wye |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
45° Wye - Double Reducing |
|||||||
2" x 2" x 1/2" x 1/2" | 3" x 3" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | 4" x 4" x 2" x 2" | ||||
4" x 4" x 3" x 3" | |||||||
45° Wye - Reducing |
|||||||
2" x 2" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 2" | 4" x 4" x 3" | ||||
Cap |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Cleanout Adapter |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Cleanout Tee with Plug (S x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Coupling |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Double Reducing Tee |
|||||||
2" x 2" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | ||||||
Double Sanitary Tee |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Female Adapter (FPT x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Flange |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Long Turn Tee |
|||||||
1 1/2" | 2" | 2" x 2" x 1 1/2" | 3" | ||||
3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" | 4" x 4" x 2" | ||||
4" x 4" x 3" | |||||||
Male Adapter (MPT x S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Male Union Adapter - FPT |
|||||||
2" | |||||||
Male Union Adapter - MPT |
|||||||
2" | |||||||
Male Union Adapter - S |
|||||||
1 1/2" | |||||||
Male Union Adapter - Spg |
|||||||
2" | |||||||
P-Trap - Slip Joint Inlet |
|||||||
1 1/2" | |||||||
P-Trap - Union |
|||||||
1 1/2" | 2" | ||||||
P-Trap - With Cleanout |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
P-Trap - Without Cleanout |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Pipe Increaser |
|||||||
1 1/2" x 2" | 2" x 3" | 2" x 4" | 3" x 4" | ||||
Plug |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Reducer Bushing (Spg x S) |
|||||||
2" x 1 1/2" | 3" x 1 1/2" | 3" x 2" | 4" x 2" | ||||
4" x 3" | |||||||
Sanitary Tee |
|||||||
1 1/2" | 2" | 2" x 2" x 1 1/2" | 3" | ||||
3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" | 4" x 4" x 2" | ||||
4" x 4" x 3" | |||||||
Strainer Adapter |
|||||||
1 1/2" | |||||||
Swivel Strainer Adapter |
|||||||
1 1/2" | 1 1/2" x 12L | ||||||
Union Nut Adapter - S |
|||||||
1 1/2" | 2" | ||||||
Union Nut Adapter - Spg |
|||||||
1 1/2" | |||||||
Unions |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Pipe (CW)¢ § |
PVDF |
Fuseal 25/50 |
CSA B181.3 |
||||
1 1/2" - 6" 37C0130XX Sch 40 | |||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Pipe (CW)¢ § |
PVDF |
Fuseal 25/50 |
ASTM F1673 |
||||
1 1/2" - 6" 37C0130XX Sch 40 | |||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Fittings (CW)¢ § |
PVDF |
Fuseal 25/50 |
CSA B181.3 |
||||
Female Adapter (SxFPT) |
|||||||
3" | 4" | 6" | |||||
Glass Adapter (SxBead Glass Pipe) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Iron Pipe Adapter (SxIron Pipe Bead) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Flange (S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Union (PVDFxPVDF)/PVDF Nut EPDM (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Union (PVDFxPVDF)/PVDF Nut FPM (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Union (PPFRxPVDF)/PPFR Nut EPDM (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Union (PPFRxPVDF)/PPFR Nut FPM (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Union (PVDFxPPFR)/PVDF Nut EPDM (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Clean-Out Adapter w/Plug (SpgxFT) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Countersink Plug for Cleanout |
|||||||
3" | 4" | ||||||
P-Trap Cleanout (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
P-Trap (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
P-Trap Union Connection (SxS) |
|||||||
1 1/2" | |||||||
Double 45° Wye (SxSxSxS) |
|||||||
3" | 4" | ||||||
Double 45° Wye - Reducing (SxSxSxS) - BUSH |
|||||||
2" x 2" x 1 1/2" x 1 1/2" | 3" x 3" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | 4" x 4" x 2" x 2" | ||||
4" x 4" x 3" x 3" | |||||||
Long Turn Tee Wye (SxSxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Combo Wye (SxSxS) - FAB |
|||||||
6" | |||||||
Long Turn Tee Wye - Reducing (SxSxS) - BUSH |
|||||||
2" x 2" x 1 1/2" | 3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 2" | ||||
4" x 4" x 3" | |||||||
Combo Wye - Reducing (SxSxS) - FAB |
|||||||
6" x 6" x 3" | 6" x 6" x 4" | ||||||
Double Combo Wye (SxSxSxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Double Combo Wye - Reducing (SxSxSxS) - BUSH |
|||||||
2" x 2" x 1 1/2" x 1 1/2" | 3" x 3" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | 4" x 4" x 2" x 2" | ||||
4" x 4" x 3" x 3" | |||||||
Sanitary Tee (SxSxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Sanitary Tee - Reducing (SxSxS) - BUSH |
|||||||
2" x 2" x 1 1/2" | 3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 2" | ||||
4" x 4" x 3" | |||||||
Double Sanitary Tee (SxSxSxS) |
|||||||
2" | |||||||
P-Trap Union Connection (SxS) |
|||||||
2" | |||||||
Swivel Sink Strainer Adapter (SpgxFT) |
|||||||
1 1/2" | |||||||
Swivel Sink Strainer Replacement Gasket |
|||||||
1 1/2" | |||||||
FPT Trap Primer (SpgxSPG) - FAB |
|||||||
1 1/2" x 1/2" | 2" x 1/2" | 3" x 1/2" | 4" x 1/2" | ||||
6" x 3/4" | |||||||
Female Adapter (SxFPT) |
|||||||
2" | |||||||
Double Sanitary Tee (SxSxSxS) |
|||||||
3" | |||||||
Double Sanitary Tee - Reducing (SxSxSxS) - BUSH |
|||||||
2" x 2" x 1 1/2" x 1 1/2" | 3" x 3" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | |||||
Pipe Increaser (SpgxSpg) |
|||||||
2" x 1 1/2" | 3" x 1 1/2" | 3" x 2" | 4" x 2" | ||||
4" x 3" | |||||||
Reducer Bushing (SpgxS) |
|||||||
2" x 1 1/2" | 3" x 1 1/2" | 3" x 2" | 4" x 2" | ||||
4" x 3" | 6" x 4" | ||||||
Cap (S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Male Adapter (SxMPT) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Female Adapter (SxFPT) |
|||||||
1 1/2" | |||||||
Coupling (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
1/4" Bend - Long Sweep (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/4" Bend - Short Sweep (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/8" Bend (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
45° Wye (SxSxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
45° Wye - Reducing (SxSxS) - BUSH |
|||||||
2" x 2" x 1 1/2" | 3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 2" | ||||
4" x 4" x 3" | |||||||
Double 45° Wye (SxSxSxS) |
|||||||
1 1/2" | 2" | ||||||
Union (PVDFxPPFR)/PVDF Nut FPM (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1-1/2" Clean-Out Tee w/Plug (SxSxFT) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6"-FAB | |||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Fittings (CW)¢ § |
PVDF |
Fuseal 25/50 |
ASTM F1673 |
||||
45° Wye (SxSxS) |
|||||||
3" | 4" | 6" | |||||
45° Wye - Reducing (SxSxS) - BUSH |
|||||||
2" x 2" x 1 1/2" | 3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 2" | ||||
4" x 4" x 3" | |||||||
Double 45° Wye (SxSxSxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Double 45° Wye - Reducing (SxSxSxS) - BUSH |
|||||||
2" x 2" x 1 1/2" x 1 1/2" | 3" x 3" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | 4" x 4" x 2" x 2" | ||||
4" x 4" x 3" x 3" | |||||||
Long Turn Tee Wye (SxSxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Combo Wye (SxSxS) - FAB |
|||||||
6" | |||||||
Long Turn Tee Wye - Reducing (SxSxS) - BUSH |
|||||||
2" x 2" x 1 1/2" | 3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 2" | ||||
4" x 4" x 3" | |||||||
Combo Wye - Reducing (SxSxS) - FAB |
|||||||
6" x 6" x 3" | 6" x 6" x 4" | ||||||
Double Combo Wye (SxSxSxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Double Combo Wye - Reducing (SxSxSxS) - BUSH |
|||||||
2" x 2" x 1 1/2" x 1 1/2" | 3" x 3" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | 4" x 4" x 2" x 2" | ||||
Pipe Increaser (SpgxSpg) |
|||||||
4" x 3" | |||||||
Reducer Bushing (SpgxS) |
|||||||
2" x 1 1/2" | 3" x 1 1/2" | 3" x 2" | 4" x 2" | ||||
4" x 3" | 6" x 4" | ||||||
Cap (S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Male Adapter (SxMPT) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Female Adapter (SxFPT) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Glass Adapter (SxBead Glass Pipe) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Iron Pipe Adapter (SxIron Pipe Bead) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Flange (S) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Union (PVDFxPVDF)/PVDF Nut EPDM (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Union (PVDFxPVDF)/PVDF Nut FPM (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Union (PPFRxPVDF)/PPFR Nut EPDM (SxS) |
|||||||
1 1/2" | |||||||
1/4" Bend - Short Sweep (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Coupling (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
1/4" Bend - Long Sweep (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1/8" Bend (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
45° Wye (SxSxS) |
|||||||
1 1/2" | 2" | ||||||
Union (PPFRxPVDF)/PPFR Nut EPDM (SxS) |
|||||||
2" | 3" | 4" | |||||
Union (PPFRxPVDF)/PPFR Nut FPM (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Union (PVDFxPPFR)/PVDF Nut EPDM (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Union (PVDFxPPFR)/PVDF Nut FPM (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
1 1/2" Clean-Out Tee w/Plug (SxSxFT) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6"-FAB | |||||||
Clean-Out Adapter w/Plug (SpgxFT) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
Countersink Plug for Cleanout |
|||||||
3" | 4" | ||||||
P-Trap Cleanout (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
P-Trap (SxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
6" | |||||||
P-Trap Union Connection (SxS) |
|||||||
1 1/2" | 2" | ||||||
Swivel Sink Strainer Adapter (SpgxFT) |
|||||||
1 1/2" | |||||||
Swivel Sink Strainer Replacement Gasket |
|||||||
1 1/2" | |||||||
FPT Trap Primer (SpgxSPG) - FAB |
|||||||
1 1/2" x 1/2" | 2" x 1/2" | 3" x 1/2" | 4" x 1/2" | ||||
6" x 3/4" | |||||||
Double Combo Wye - Reducing (SxSxSxS) - BUSH |
|||||||
4" x 4" x 3" x 3" | |||||||
Sanitary Tee (SxSxS) |
|||||||
1 1/2" | 2" | 3" | 4" | ||||
Sanitary Tee - Reducing (SxSxS) - BUSH |
|||||||
2" x 2" x 1 1/2" | 3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 2" | ||||
4" x 4" x 3" | |||||||
Double Sanitary Tee (SxSxSxS) |
|||||||
2" | 3" | ||||||
Double Sanitary Tee - Reducing (SxSxSxS) - BUSH |
|||||||
2" x 2" x 1 1/2" x 1 1/2" | 3" x 3" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | |||||
Pipe Increaser (SpgxSpg) |
|||||||
2" x 1 1/2" | 3" x 1 1/2" | 3" x 2" | 4" x 2" | ||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
Potable Water - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard | ||||
Fittings+ *** [G] |
PVC |
+GF+ or GSR |
ASTM D2464 |
||||
Tees, T x T x T |
|||||||
805-xxx | 1/4" - 4" | ||||||
Tees, S x S x T |
|||||||
802-xxx | 1/2" - 2" | ||||||
90° Ell, S x T |
|||||||
807-xxx | 1/2" - 3" | ||||||
90° Ell, T x T |
|||||||
808-xxx | 1/4" - 4" | ||||||
45° Ell, T x T |
|||||||
819-xxx | 1/4" - 4" | ||||||
Coupling, T x T |
|||||||
830-xxx | 1/4" - 4" | ||||||
Reducer Coupling, T x T |
|||||||
830-xxx | 3/8" x 1/4" | 3/4" x 1/2" | 1/2" x 3/8" | ||||
1/2" x 3/4" | 1/2" x 1/4" | 1" x 1/2" | 1" x 3/4" | ||||
1 1/4" x 3/4" | 1 1/2" x 1" | 2" x 1 1/2" | |||||
Female Adapter, S x T |
|||||||
835-xxx | 1/4" - 4" | ||||||
Male Adapter, S x MT |
|||||||
836-xxx | 1/2" - 4" | ||||||
Nipple, MT x MT |
|||||||
861-xxx | 1/2" - 3" | ||||||
Reducer Bushing, Spg x T |
|||||||
838-xxx | 3/8" x 1/4" | 1/2" x 1/4" | 1/2" x 3/8" | ||||
3/4" x 1/4" | 3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" | ||||
1 1/4" x 1/2" | 1 1/4" x 3/4" | 1 1/4" x 1" | 1 1/4" x 1/2" | ||||
1 1/4" x 1 1/4" | 1 1/2" x 1/2" | 1 1/2" x 3/4" | 1 1/2" x 1" | ||||
1 1/2" x 1 1/4" | 2" x 1/2" | 2" x 3/4" | 2" x 1" | ||||
2" x 1 1/4" | 2" x 1 1/2" | 2 1/2" x 1 1/2" | 2 1/2" x 2" | ||||
3" x 2" | 3" x 2 1/2" | 4" x 2" | 4" x 3" | ||||
Reducer Bushing, MT x T |
|||||||
839-xxx | 3/8" x 1/4" | 1/2" x 1/4" | 1/2" x 3/8" | ||||
3/4" x 1/4" | 3/4" x 3/8" | 3/4" x 1/2" | 1" x 1/4" | ||||
1" x 1/2" | 1" x 3/4" | 1 1/4" x 1/2" | 1 1/4" x 3/4" | ||||
1 1/4" x 1" | 1 1/2" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" | ||||
2" x 1/2" | 2" x 3/4" | 2" x 1" | 2" x 1 1/4" | ||||
2" x 1 1/2" | 3" x 2" | 4" x 2" | 4" x 3" | ||||
Cap, T |
|||||||
848-xxx | 1/4" - 4" | ||||||
Plug, MT |
|||||||
850-xxx | 1/4" - 4" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. *** -xxx Suffix designates nominal size [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Fittings+ *** [G] |
PVC |
+GF+ or GSR |
ASTM D2466 |
||||
Tee, S x S x S |
|||||||
401-xxx | 1/2" - 10" | ||||||
Tee, S x S x T |
|||||||
402-xxx | 1/2" - 12" | ||||||
Reducing Tee, S x S x S |
|||||||
401-xxx | 1/2" x 1/2" x 3/4" | 1/2" x 1/2" x 1" | 3/4" x 1/2" x 1/2" | ||||
3/4" x 1/2" x 3/4" | 3/4" x 3/4" x 1/2" | 3/4" x 3/4" x 1" | 1" x 1/2" x 1" | ||||
1" x 3/4" x 1/2" | 1" x 3/4" x 3/4" | 1" x 1" x 1/2" | 1" x 1" x 3/4" | ||||
1" x 1" x 1 1/4" | 1" x 1" x 1 1/2" | 1 1/4" x 1" x 1/2" | 1 1/4" x 1" x 1" | ||||
1 1/4" x 1 1/4" x 1/2" | 1 1/4" x 1 1/4" x 3/4" | 1 1/4" x 1 1/4" x 1" | 1 1/4" x 1 1/4" x 1 1/2" | ||||
1 1/4" x 1 1/4" x 2" | 1 1/2" x 1 1/4" x 1/2" | 1 1/2" x 1 1/4" x 1/2" | 1 1/2" x 1 1/4" x 3/4" | ||||
1 1/2" x 1 1/4" x 1" | 1 1/2" x 1 1/2" x 1/2" | 1 1/2" x 1 1/2" x 3/4" | 1 1/2" x 1 1/2" x 1" | ||||
1 1/2" x 1 1/2" x 1 1/4" | 1 1/2" x 1 1/2" x 2" | 2" x 1/2" x 3/4" | 2" x 1 1/2" x 1" | ||||
2" x 2" x 1/2" | 2" x 2" x 3/4" | 2" x 2" x 1" | 2" x 2" x 1 1/4" | ||||
2" x 2" x 1 1/2" | 2 1/2" x 2 1/2" x 1/2" | 2 1/2" x 2 1/2" x 3/4" | 2 1/2" x 2 1/2" x 1" | ||||
3" x 3" x 1/2" | 3" x 3" x 3/4" | 3" x 3" x 1" | 3" x 3" x 1 1/4" | ||||
3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 1/2" | 4" x 4" x 3/4" | ||||
4" x 4" x 1" | 4" x 4" x 1 1/4" | 4" x 4" x 1 1/2" | 4" x 4" x 2" | ||||
4" x 4" x 3" | 6" x 6" x 2" | 6" x 6" x 3" | 6" x 6" x 4" | ||||
8" x 8" x 3" | 8" x 8" x 4" | ||||||
Reducing Tee, S x S x T |
|||||||
402-xxx | 1/2" x 1/2" x 3/4" | 3/4" x 1/2" x 1/2" | 3/4" x 1/2" x 3/4" | ||||
3/4" x 3/4" x 1/2" | 1" x 3/4" x 1/2" | 1" x 1" x 1/2" | 1" x 1" x 3/4" | ||||
1 1/4" x 1" x 1/2" | 1 1/4" x 1" x 1" | 1 1/4" x 1 1/4" x 1/2" | 1 1/4" x 1 1/4" x 3/4" | ||||
1 1/4" x 1 1/4" x 1" | 1 1/2" x 1 1/4" x 1/2" | 1 1/2" x 1 1/4" x 3/4" | 1 1/2" x 1 1/4" x 1" | ||||
1 1/2" x 1 1/2" x 3/4" | 1 1/2" x 1 1/2" x 1" | 1 1/2" x 1 1/2" x 1/2" | 1 1/2" x 1 1/2" x 3/4" | ||||
1 1/2" x 1 1/2" x 1" | 1 1/2" x 1 1/2" x 1 1/4" | 2" x 1 1/2" x 3/4" | 2" x 1 1/2" x 1" | ||||
2" x 2" x 1/2" | 2" x 2" x 3/4" | 2" x 2" x 1" | 2" x 2" x 1 1/4" | ||||
2" x 2" x 1 1/2" | 2 1/2" x 2 1/2" x 3/4" | 2 1/2" x 2 1/2" x 1" | 4" x 4" x 3" | ||||
6" x 6" x 3" | |||||||
90° Ell, S x S |
|||||||
406-xxx | 1/2" - 12" | ||||||
90° Reducing Ell, S x S |
|||||||
406-xxx | 3/4" x 1/2" | 1 1/4" x 1" | 1" x 1/2" | ||||
1 1/2" x 1" | 1" x 3/4" | ||||||
90° Ell, S x T |
|||||||
407-xxx | 1/2" x 3/4" | 1" x 3/4" | 3/4" x 1/2" | ||||
1 1/4" x 1" | 1" x 1/2" | 1 1/2" x 1" | |||||
90° Ell, S x FT |
|||||||
407-xxx | 1/2" - 2" | ||||||
90° Ell, T x T |
|||||||
408-xxx | 1/2" - 1 1/4" | ||||||
90° Street Ell, Spg x S |
|||||||
409-xxx | 1/2" - 2" | ||||||
90° Street Ell, Mt x S |
|||||||
410-xxx | 1/2" - 2" | ||||||
90° Street Ell, MT x FT |
|||||||
412-xxx | 1/2" - 2" | ||||||
45° Ell, S x S |
|||||||
417-xxx | 1/2" - 8" | ||||||
Crosses, S x S x S x S |
|||||||
420-xxx | 1/2" - 2" | 2 1/2" x 2 1/2" x 2 1/2" x 1 1/2" | 3" x 3" x 1 1/2" x 1 1/2" | ||||
4" x 4" x 1" x 1" | 4" x 4" x 2" x 2" | 3" x 3" x 1" x 1" | 3" x 3" x 2" x 2" | ||||
4" x 4" x 1 1/2" x 1 1/2" | |||||||
Coupling, S x S |
|||||||
429-xxx | 1/2" - 12" | 3/4" x 1/2" | 1" x 3/4" | ||||
Coupling, T x T |
|||||||
430-xxx | 1/2" - 1" | ||||||
Female Adapter, S x T |
|||||||
435-xxx | 1/2" - 8" | 3/4" x 1/2" | 3/4" x 1" | ||||
1" x 3/4" | |||||||
Male Adapter, MT x S |
|||||||
436-xxx | 1/2" - 6" | 1/2" x 3/4" | 3/4" x 1/2" | ||||
3/4" x 1" | 1" x 3/4" | 1" x 1 1/4" | 1 1/4" x 1" | ||||
1 1/4" x 1 1/2" | 1 1/2" x 1 1/4" | 1 1/2" x 2" | 2" x 1 1/2" | ||||
3" x 4" | |||||||
Reducer Bushing, Spg x S |
|||||||
437-xxx | 3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" | ||||
1 1/4" x 1/2" | 1 1/4" x 3/4" | 1 1/4" x 1" | 1 1/2" x 1/2" | ||||
1 1/2" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" | 1 1/2" x 1" | ||||
2" x 1/2" | 2" x 3/4" | 2" x 1" | 2" x 1 1/4" | ||||
2" x 1 1/2" | 2 1/2" x 3/4" | 2 1/2" x 1" | 2 1/2" x 1 1/4" | ||||
2 1/2" x 1 1/2" | 2 1/2" x 2" | 3" x 1" | 3" x 1 1/4" | ||||
3" x 1 1/2" | 3" x 2" | 3" x 2 1/2" | 4" x 2" | ||||
4" x 2 1/2" | 4" x 3" | 5" x 4" | 6" x 3" | ||||
6" x 4" | 6" x 4" | 6" x 5" | 8" x 2" | ||||
8" x 4" | 8" x 6" | 10" x 8" | |||||
Reducer Bushing, Spg x T |
|||||||
438-xxx | 1/2" x 1/4" | 1/2" x 3/8" | 3/4" x 1/4" | ||||
3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" | 1 1/4" x 1/2" | ||||
1 1/4" x 3/4" | 1 1/4" x 1" | 1 1/4" x 1 1/2" | 1 1/2" x 1/2" | ||||
1 1/2" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" | 2" x 1/2" | ||||
2" x 3/4" | 2" x 1" | 2" x 1 1/4" | 2" x 1 1/2" | ||||
2 1/2" x 1 1/2" | 2 1/2" x 2" | 3" x 3/4" | 3" x 1" | ||||
3" x 2" | 3" x 2 1/2" | 4" x 1" | 4" x 2" | ||||
4" x 2 1/2" | 4" x 3" | 6" x 4" | |||||
Reducer Bushing, MT x T |
|||||||
439-xxx | 1/2" x 3/8" | 3/4" x 1/2" | 1" x 3/4" | ||||
1 1/4" x 3/4" | 1 1/4" x 1" | 1 1/2" x 1/2" | 1 1/2" x 3/4" | ||||
1 1/2" x 1" | 1 1/2" x 1 1/4" | 2" x 1" | 2" x 1 1/2" | ||||
Cap, S |
|||||||
447-xxx | 1/2" - 12" | ||||||
Cap, T |
|||||||
448-xxx | 1/2" - 6" | ||||||
Plug, MT |
|||||||
450-xxx | 1/2" - 4" | ||||||
Plug, S |
|||||||
449-xxx | 1/2" - 4" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. *** -xxx Suffix designates nominal size [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Fittings+ @ *** [G] |
PVC |
+GF+ or GSR |
ASTM D2467 |
||||
Tee, S x S x S |
|||||||
801-xxx | 1/4" - 12" | ||||||
Reducing Tee, S x S x S |
|||||||
801-xxx | 3/4" x 3/4" x 1/2" | 1" x 1" x 1/2" | 1" x 1" x 3/4" | ||||
1 1/4" x 1 1/4" x 1" | 1 1/2" x 1 1/2" x 1/2" | 1 1/2" x 1 1/2" x 3/4" | 1 1/2" x 1 1/2" x 1" | ||||
1 1/2" x 1 1/2" x 1 1/4" | 2" x 2" x 1/2" | 2" x 2" x 3/4" | 2" x 2" x 1" | ||||
2" x 2" x 1 1/2" | 2 1/2" x 2 1/2" x 2" | 3" x 3" x 1 1/2" | 3" x 3" x 2" | ||||
4" x 4" x 2" | 4" x 4" x 2" | 4" x 4" x 3" | 6" x 6" x 4" | ||||
8" x 8" x 6" | |||||||
90° Ell, S x S |
|||||||
806-xxx | 1/4" - 12" | ||||||
45° Ell, S x S |
|||||||
817-xxx | 1/4" - 12" | ||||||
Coupling, S x S |
|||||||
829-xxx | 1/4" - 12" | ||||||
Reducer Coupling, S x S |
|||||||
829-xxx | 3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" | ||||
1 1/4" x 3/4" | 1 1/4" x 1" | 1 1/2" x 3/4" | 1 1/2" x 1" | ||||
1 1/2" x 1 1/4" | 2" x 1" | 2" x 1 1/4" | 2" x 1 1/2" | ||||
2 1/2" x 1 1/2" | 3" x 2" | 4" x 3" | 6" x 4" | ||||
8" x 6" | |||||||
Reducer Bushing, Spg x S |
|||||||
837-xxx | 1/2" x 1/4" | 1/2" x 3/8" | 3/4" x 1/2" | ||||
1" x 1/2" | 1" x 3/4" | 1 1/4" x 1/2" | 1 1/4" x 3/4" | ||||
1 1/4" x 1" | 1 1/2" x 1/2" | 1 1/2" x 3/4" | 1 1/2" x 1" | ||||
1 1/2" x 1 1/4" | 2" x 1/2" | 2" x 3/4" | 2" x 1" | ||||
2" x 1 1/4" | 2" x 1 1/2" | 2 1/2" x 1 1/2" | 2 1/2" x 2" | ||||
3" x 1 1/2" | 3" x 2" | 3" x 2 1/2" | 4" x 2" | ||||
4" x 3" | 6" x 3" | 6" x 4" | 8" x 6" | ||||
10" x 6" | 10" x 8" | 12" x 8" | 12" x 10" | ||||
Cap, S |
|||||||
847-xxx | 1/4" - 12" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. @ Fittings or systems to be installed in accordance with the manufacturer's instructions, ASTM Standard and latest edition of Uniform Plumbing Code. *** -xxx Suffix designates nominal size [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Fittings+ @ *** [G] |
PVC |
+GF+ or GSR |
ASTM D2467 |
||||
Tees, T x T x T |
|||||||
805-xxx | 1/4" - 12" | ||||||
Tees, S x S x T |
|||||||
802-xxx | 1/2" - 12" | ||||||
90° Ell, S x T |
|||||||
807-xxx | 1/2" - 12" | ||||||
90° Ell, T x T |
|||||||
808-xxx | 1/4" - 12" | ||||||
45° Ell, T x T |
|||||||
819-xxx | 1/4" - 12" | ||||||
Coupling, T x T |
|||||||
830-xxx | 1/4" - 4" | ||||||
Reducer Coupling, T x T |
|||||||
830-xxx | 3/8" x 1/4" | 3/4" x 1/2" | 1 1/4" x 3/4" | ||||
1/2" x 1/4" | 1" x 1/2" | 1 1/2" x 1" | 1/2" x 3/4" | ||||
1" x 3/4" | 2" x 1 1/2" | ||||||
Female Adapter, S x T |
|||||||
835-xxx | 1/4" - 4" | ||||||
Male Adapter, S x T |
|||||||
836-xxx | 1/2" - 4" | ||||||
Nipple, MT x MT |
|||||||
861-xxx | 1/2" x 3" | ||||||
Reducer Bushing, Spg x T |
|||||||
838-xxx | 3/8" x 1/4" | 1/2" x 1/4" | 1/2" x 3/8" | ||||
3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" | 1 1/4" x 1/2" | ||||
1 1/4" x 3/4" | 1 1/4" x 1" | 1 1/2" x 1/2" | 1 1/2" x 3/4" | ||||
1 1/2" x 1" | 1 1/2" x 1 1/4" | 2" x 1/2" | 2" x 3/4" | ||||
2" x 1" | 2" x 1 1/4" | 2" x 1 1/2" | 2 1/2" x 1 1/2" | ||||
2 1/2" x 2" | 3" x 2" | 3" x 2 1/2" | 4" x 2" | ||||
Reducer Bushing, MT x T |
|||||||
839-xxx | 3/8" x 1/4" | 1/2" x 1/4" | 1/2" x 3/8" | ||||
3/4" x 1/4" | 3/4" x 3/8" | 3/4" x 1/2" | 1" x 1/4" | ||||
1" x 1/2" | 1" x 3/4" | 1 1/4" x 1/2" | 1 1/4" x 3/4" | ||||
1 1/4" x 1" | 1 1/2" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" | ||||
2" x 1/2" | 2" x 3/4" | 2" x 1" | 2" x 1 1/4" | ||||
2 1/2" x 2" | 3" x 2" | 4" x 2" | 4" x 3" | ||||
Cap, T |
|||||||
848-xxx | 1/4" - 4 | ||||||
Plug, MT |
|||||||
850-xxx | 1/4" - 4" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. @ Fittings or systems to be installed in accordance with the manufacturer's instructions, ASTM Standard and latest edition of Uniform Plumbing Code. *** -xxx Suffix designates nominal size [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Fittings@ *** +++ [G] |
CPVC |
+GF+ or GSR |
ASTM F439 |
||||
Tee, S x S x S |
|||||||
9801-xxx | 1/4" - 12" | ||||||
Reducing Tee, S x S x S |
|||||||
9801-xxx | 3/4" x 3/4" x 1/2" | 1" x 1" x 1/2" | 1" x 1" x 3/4" | ||||
1 1/4" x 1 1/4" x 1" | 1 1/2" x 1 1/2" x 3/4" | 1 1/2" x 1 1/2" x 1" | 1 1/2" x 1 1/2" x 1 1/4" | ||||
1 1/2" x 1 1/2" x 1 1/2" | 2" x 2" x 1/2" | 2" x 2" x 3/4" | 2" x 2" x 1" | ||||
2" x 2" x 1 1/2" | 2 1/2" x 2 1/2" x 2" | 3" x 3" x 1 1/2" | 3" x 3" x 2" | ||||
4" x 4" x 2" | 4" x 4" x 3" | 6" x 4" | 8" x 8" x 6" | ||||
90° Ell, S x S |
|||||||
9806-xxx | 1/4" - 12" | ||||||
45° Ell, S x S |
|||||||
9817-xxx | 1/4" - 12" | ||||||
Coupling, S x S |
|||||||
9829-xxx | 1/4" - 12" | ||||||
Reducer Coupling, S x S |
|||||||
9829-xxx | 1/2" x 3/8" | 3/4" x 1/2" | 1" x 1/2" | ||||
1" x 3/4" | 1 1/4" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" | ||||
2" x 1" | 2" x 1 1/4" | 2" x 1 1/2" | 2 1/2" x 1 1/2" | ||||
3" x 2" | 4" x 3" | 6" x 4" | 8" x 6" | ||||
Reducer Bushing, Spg x S |
|||||||
9837-xxx | 1/2" x 1/4" | 1/2" x 3/8" | 3/4" x 1/2" | ||||
1" x 1/2" | 1" x 3/4" | 1 1/4" x 1/2" | 1 1/4" x 3/4" | ||||
1 1/4" x 1" | 1 1/2" x 1/2" | 1 1/2" x 3/4" | 1 1/2" x 1" | ||||
1 1/2" x 1 1/4" | 2" x 1/2" | 2" x 3/4" | 2" x 1" | ||||
2" x 1 1/4" | 2" x 1 1/2" | 2 1/2" x 1 1/2" | 2 1/2" x 2" | ||||
3" x 1 1/2" | 3" x 2" | 3" x 2 1/2" | 4" x 2" | ||||
4" x 3" | 6" x 4" | 8" x 6" | 10" x 6" | ||||
10" x 8" | 12" x 10" | ||||||
Cap, S |
|||||||
9847-xxx | 3/8" - 12" | ||||||
@ Fittings or systems to be installed in accordance with the manufacturer's instructions, ASTM Standard and latest edition of Uniform Plumbing Code. *** -xxx Suffix designates nominal size +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Fittings*** +++ [G] |
CPVC |
+GF+ or GSR |
ASTM F437 |
||||
Tee, T x T x T |
|||||||
9805-xxx | 1/4" - 12" | ||||||
90° Ell, T x T |
|||||||
9808-xxx | 1/4" - 12" | ||||||
90° Ell, S x FPT |
|||||||
9807-XXX | 1/2" - 1" | ||||||
45° Ell, T x T |
|||||||
9819-xxx | 1/4" - 12" | ||||||
Coupling, T x T |
|||||||
9830-xxx | 1/4" - 4" | ||||||
Reducer Coupling, T x T |
|||||||
9830-xxx | 1/2" x 1/4" | 1/2" x 3/8" | 3/4" x 1/2" | ||||
1" x 1/2" | 1" x 3/4" | 1 1/2" x 1" | |||||
Female Adapter, S x T |
|||||||
9835-xxx | 1/4" - 4" | ||||||
Male Adapter, S x MT |
|||||||
9836-xxx | 1/2" - 4" | ||||||
Reducer Bushing, Spg x T |
|||||||
9838-xxx | 3/8" x 1/4" | 1/2" x 1/4" | 1/2" x 3/8" | ||||
3/4" x 1/4" | 3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" | ||||
1 1/4" x 1/2" | 1 1/4" x 3/4" | 1 1/4" x 1" | 1 1/2" x 1/2" | ||||
1 1/2" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" | 2" x 1/2" | ||||
2" x 3/4" | 2" x 1" | 2" x 1 1/4" | 2" x 1 1/2" | ||||
2 1/2" x 1 1/2" | 2 1/2" x 2" | 3" x 2" | 4" x 2" | ||||
4" x 3" | |||||||
Reducer Bushing, MT x T |
|||||||
9839-xxx | 3/8" x 1/4" | 1/2" x 1/4" | 1/2" x 3/8" | ||||
3/4" x 3/8" | 3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" | ||||
1 1/4" x 1" | 1 1/2" x 1/2" | 1 1/2" x 3/4" | 1 1/2" x 1" | ||||
1 1/2" x 1 1/4" | 2" x 3/4" | 2" x 1" | 2" x 1 1/4" | ||||
2" x 1 1/2" | 3" x 2" | 4" x 3" | |||||
Cap, T |
|||||||
9848-xxx | 1/4" - 4" | ||||||
Plug, MT |
|||||||
9850-xxx | 1/4" - 4" | ||||||
Nipple, MT x MT |
|||||||
9861-xxx | 1/4" - 2" | ||||||
*** -xxx Suffix designates nominal size +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Pipe+ @ ^ § [G] |
PVC |
+GF+ or GSR |
ASTM D1785 |
||||
>= 1/2" Sch 80 | |||||||
>= 1/2" Sch 40 | |||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. @ Fittings or systems to be installed in accordance with the manufacturer's instructions, ASTM Standard and latest edition of Uniform Plumbing Code. ^ Sockets and gasketed bell ends are not tested or Listed by NSF for this production facility. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Pipe+ |
PVC |
+GF+ or GSR |
CSA B137.3 |
||||
>= 1/2" Sch 40 | |||||||
>= 1/2" Sch 80 | |||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. |
|||||||
Pipe@ ¢ § +++ [G] |
CPVC 4120 |
+GF+ or GSR |
ASTM F441 |
||||
1/2" - 2", 2 1/2", 3", 4", 6", 8", 10", 12" Sch 40 | |||||||
1/2" - 2", 2 1/2", 3", 4", 6", 8", 10", 12" Sch 80 | |||||||
@ Fittings or systems to be installed in accordance with the manufacturer's instructions, ASTM Standard and latest edition of Uniform Plumbing Code. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Pipe¢ +++ [G] |
CPVC 4120 |
+GF+ or GSR |
CSA B137.6 |
||||
1 1/4" - 2 1/2" Sch 40 | |||||||
1 1/4" - 2 1/2" Sch 80 | |||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Fittings# + [1] [G] |
PVC |
+GF+ |
ASTM F1970 |
||||
Flange - Van Stone (S) Sch 80 |
|||||||
1/2" - 12" (854-XXX) | |||||||
# Product tested for use in 73°F with a rated pressure of 150 psi. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [1] XXX-indicates size [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Fittings# + [G] |
PVC |
+GF+ |
ASTM F1970 |
||||
Flange - Van Stone (FPT) Sch 80 |
|||||||
1/2" - 4" (855-XXX) | |||||||
Flange - Van Stone (SPG) Sch 80 |
|||||||
1/2" - 12" (856-XXX) | |||||||
# Product tested for use in 73°F with a rated pressure of 150 psi. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Fittings# ++ [G] |
MLTPL |
+GF+ |
ASTM F1970 |
||||
Female Adapters Sch 80 |
|||||||
1/2" (868-005ss) | 3/4" (868-007ss) | 1" (868-010ss) | 1 1/4" (868-012ss) | ||||
1 1/2" (868-015ss) | 2" (868-020ss) | ||||||
Male Adapters Sch 80 |
|||||||
1/2" (869-005ss) | 3/4" (869-007ss) | 1" (869-010ss) | 1 1/4" (869-012ss) | ||||
1 1/2" (869-015ss) | 2" (869-020ss) | ||||||
# Product tested for use in 73°F with a rated pressure of 150 psi. ++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Domestic Hot (140° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Fittings# +++ [1] [G] |
CPVC |
+GF+ |
ASTM F1970 |
||||
Flange - Van Stone (FPT) Sch 80 |
|||||||
1" - 2" (9855-XXX) | |||||||
Flange - Van Stone (S) Sch 80 |
|||||||
1/2" - 12" (9854-XXX) | |||||||
Flange - Van Stone (SPG) Sch 80 |
|||||||
1/2" - 12" (9856-XXX) | |||||||
# Product tested for use in 73°F with a rated pressure of 150 psi. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [1] XXX-indicates size [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Pipe@ ¢ +++ [G] |
CPVC 4120 |
ChlorFIT® |
ASTM F441 |
||||
1/2" - 2", 2 1/2", 3", 4", 6", 8", 10", 12" Sch 40 | |||||||
1/2" - 2", 2 1/2", 3", 4", 6", 8", 10", 12" Sch 80 | |||||||
@ Fittings or systems to be installed in accordance with the manufacturer's instructions, ASTM Standard and latest edition of Uniform Plumbing Code. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Pipe¢ +++ [G] |
CPVC 4120 |
ChlorFIT® |
CSA B137.6 |
||||
1 1/4" - 2 1/2" Sch 40 | |||||||
1 1/4" - 2 1/2" Sch 80 | |||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Pipe+ ¢ [G] |
PVC |
+GF+ Harvel® Industrial* |
CSA B137.3 |
||||
1/2" Sch 40 | |||||||
1/2" Sch 80 | |||||||
3/4" Sch 40 | |||||||
3/4" Sch 80 | |||||||
1" Sch 40 | |||||||
1" Sch 80 | |||||||
1 1/4" Sch 40 | |||||||
1 1/4" Sch 80 | |||||||
1 1/2" Sch 40 | |||||||
1 1/2" Sch 80 | |||||||
2" Sch 40 | |||||||
2" Sch 80 | |||||||
2 1/2" Sch 40 | |||||||
2 1/2" Sch 80 | |||||||
3" Sch 40 | |||||||
3" Sch 80 | |||||||
4" Sch 40 | |||||||
4" Sch 80 | |||||||
5" Sch 80 | |||||||
6" Sch 40 | |||||||
6" Sch 80 | |||||||
8" Sch 40 | |||||||
8" Sch 80 | |||||||
10" Sch 80 | |||||||
12" Sch 40 | |||||||
12" Sch 80 | |||||||
14" Sch 40 | |||||||
14" Sch 80 | |||||||
16" Sch 40 | |||||||
16" Sch 80 | |||||||
20" Sch 40 | |||||||
20" Sch 80 | |||||||
24" Sch 80 | |||||||
* May also be representated by +GF+ Harvel® Industrial PLUS. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Fittings# +++ |
CPVC |
ChlorFIT® |
ASTM F1970 |
||||
1/2 - 1" 90DEG Drop Ear CPVC 80 Transition (SXFPT) | |||||||
1/2" - 2" Female Adapter Sch 80 | |||||||
1/2" - 2" Male Adapter Sch 80 | |||||||
# Product tested for use in 73°F with a rated pressure of 150 psi. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). |
|||||||
Pipe+ ¢ [G] |
PVC |
![]() |
CSA B137.3 |
||||
1/2" Sch 40 | |||||||
1/2" Sch 80 | |||||||
3/4" Sch 40 | |||||||
1" Sch 40 | |||||||
1" Sch 80 | |||||||
1 1/4" Sch 40 | |||||||
1 1/4" Sch 80 | |||||||
1 1/2" Sch 40 | |||||||
1 1/2" Sch 80 | |||||||
2" Sch 40 | |||||||
2" Sch 80 | |||||||
2 1/2" Sch 40 | |||||||
2 1/2" Sch 80 | |||||||
3" Sch 40 | |||||||
3" Sch 80 | |||||||
4" Sch 40 | |||||||
4" Sch 80 | |||||||
5" Sch 80 | |||||||
6" Sch 40 | |||||||
6" Sch 80 | |||||||
8" Sch 40 | |||||||
8" Sch 80 | |||||||
10" Sch 80 | |||||||
12" Sch 40 | |||||||
12" Sch 80 | |||||||
14" Sch 40 | |||||||
14" Sch 80 | |||||||
16" Sch 40 | |||||||
16" Sch 80 | |||||||
20" Sch 40 | |||||||
20" Sch 80 | |||||||
24" Sch 80 | |||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Fittings# +++ |
CPVC |
ChlorFIT® |
CSA B137.6 |
||||
1/2 - 1" 90DEG Drop Ear CPVC 80 Transition (SXFPT) | |||||||
1/2" - 2" Female Adapter Sch 80 | |||||||
1/2" - 2" Male Adapter Sch 80 | |||||||
# Product tested for use in 73°F with a rated pressure of 150 psi. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). |
|||||||
Fittings@ *** +++ [G] |
CPVC |
ChlorFIT® |
ASTM F439 |
||||
45° Ell, S x S |
|||||||
9817-xxx | 1/4" - 12" | ||||||
90° Ell, S x S |
|||||||
9806-xxx | 1/4" - 12" | ||||||
Cap, S |
|||||||
9847-xxx | 3/8" - 12" | ||||||
Coupling, S x S |
|||||||
9829-xxx | 1/4" - 12" | ||||||
Reducer Bushing, Spg x S |
|||||||
9837-xxx | 1/2" x 1/4" | 1/2" x 3/8" | 3/4" x 1/2" | ||||
1" x 1/2" | 1" x 3/4" | 1 1/4" x 1/2" | 1 1/4" x 3/4" | ||||
1 1/4" x 1" | 1 1/2" x 1/2" | 1 1/2" x 3/4" | 1 1/2" x 1" | ||||
1 1/2" x 1 1/4" | 2" x 1/2" | 2" x 3/4" | 2" x 1" | ||||
2" x 1 1/4" | 2" x 1 1/2" | 2 1/2" x 1 1/2" | 2 1/2" x 2" | ||||
3" x 1 1/2" | 3" x 2" | 3" x 2 1/2" | 4" x 2" | ||||
4" x 3" | 6" x 4" | 8" x 6" | 10" x 6" | ||||
Reducer Coupling, S x S |
|||||||
9829-xxx | 1/2" x 3/8" | 3/4" x 1/2" | 1" x 1/2" | ||||
1" x 3/4" | 1 1/4" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" | ||||
2" x 1" | 2" x 1 1/4" | 2" x 1 1/2" | 2 1/2" x 1 1/2" | ||||
3" x 2" | 4" x 3" | 6" x 4" | 8" x 6" | ||||
Reducing Tee, S x S x S |
|||||||
9801-xxx | 3/4" x 3/4" x 1/2" | 1" x 1" x 1/2" | 1" x 1" x 3/4" | ||||
1 1/4" x 1 1/4" x 1" | 1 1/2" x 1 1/2" x 3/4" | 1 1/2" x 1 1/2" x 1" | 1 1/2" x 1 1/2" x 1 1/4" | ||||
1 1/2" x 1 1/2" x 1 1/2" | 2" x 2" x 1/2" | 2" x 2" x 3/4" | 2" x 2" x 1" | ||||
2" x 2" x 1 1/2" | 2 1/2" x 2 1/2" x 2" | 3" x 3" x 1 1/2" | 3" x 3" x 2" | ||||
4" x 4" x 2" | 4" x 4" x 3" | 6" x 4" | 8" x 8" x 6" | ||||
Tee, S x S x S |
|||||||
9801-xxx | 1/4" - 12" | ||||||
@ Fittings or systems to be installed in accordance with the manufacturer's instructions, ASTM Standard and latest edition of Uniform Plumbing Code. *** -xxx Suffix designates nominal size +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Fittings*** +++ [G] |
CPVC |
ChlorFIT® |
ASTM F437 |
||||
45° Ell, T x T |
|||||||
9819-xxx | 1/4" - 12" | ||||||
90° Ell, S x FPT |
|||||||
9807-XXX | 1/2" - 1" | ||||||
90° Ell, T x T |
|||||||
9808-xxx | 1/4" - 12" | ||||||
Cap, T |
|||||||
9848-xxx | 1/4" - 4" | ||||||
Coupling, T x T |
|||||||
9830-xxx | 1/4" - 4" | ||||||
Female Adapter, S x T |
|||||||
9835-xxx | 1/4" - 4" | ||||||
Male Adapter, S x MT |
|||||||
9836-xxx | 1/2" - 4" | ||||||
Nipple, MT x MT |
|||||||
9861-xxx | 1/4" - 2" | ||||||
Plug, MT |
|||||||
1/4" - 4" | 9850-xxx | ||||||
Reducer Bushing, MT x T |
|||||||
9839-xxx | 3/8" x 1/4" | 1/2" x 1/4" | 1/2" x 3/8" | ||||
3/4" x 3/8" | 3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" | ||||
1 1/4" x 1" | 1 1/2" x 1/2" | 1 1/2" x 3/4" | 1 1/2" x 1" | ||||
1 1/2" x 1 1/4" | 2" x 3/4" | 2" x 1" | 2" x 1 1/4" | ||||
2" x 1 1/2" | 3" x 2" | 4" x 3" | |||||
Reducer Bushing, Spg x T |
|||||||
9838-xxx | 3/8" x 1/4" | 1/2" x 1/4" | 1/2" x 3/8" | ||||
3/4" x 1/4" | 3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" | ||||
1 1/4" x 1/2" | 1 1/4" x 3/4" | 1 1/4" x 1" | 1 1/2" x 1/2" | ||||
1 1/2" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" | 2" x 1/2" | ||||
2" x 3/4" | 2" x 1" | 2" x 1 1/4" | 2" x 1 1/2" | ||||
2 1/2" x 1 1/2" | 2 1/2" x 2" | 3" x 2" | 4" x 2" | ||||
4" x 3" | |||||||
Reducer Coupling, T x T |
|||||||
9830-xxx | 1/2" x 1/4" | 1/2" x 3/8" | 3/4" x 1/2" | ||||
1" x 1/2" | 1" x 3/4" | 1 1/2" x 1" | |||||
Tee, T x T x T |
|||||||
9805-xxx | 1/4" - 12" | ||||||
*** -xxx Suffix designates nominal size +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Pipe@ ¢ +++ [G] |
CPVC 4120 |
SeaCor® |
ASTM F441 |
||||
1/2" - 2", 2 1/2", 3", 4", 6", 8", 10", 12" Sch 40 | |||||||
1/2" - 2", 2 1/2", 3", 4", 6", 8", 10", 12" Sch 80 | |||||||
@ Fittings or systems to be installed in accordance with the manufacturer's instructions, ASTM Standard and latest edition of Uniform Plumbing Code. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Fittings*** +++ [G] |
CPVC |
SeaCor® |
ASTM F437 |
||||
45° Ell, T x T |
|||||||
9819-xxx | 1/4" - 12" | ||||||
90° Ell, S x FPT |
|||||||
9807-XXX | 1/2" - 1" | ||||||
90° Ell, T x T |
|||||||
9808-xxx | 1/4" - 12" | ||||||
Cap, T |
|||||||
9848-xxx | 1/4" - 4" | ||||||
Coupling, T x T |
|||||||
9830-xxx | 1/4" - 4" | ||||||
Female Adapter, S x T |
|||||||
9835-xxx | 1/4" - 4" | ||||||
Male Adapter, S x MT |
|||||||
9836-xxx | 1/2" - 4" | ||||||
Nipple, MT x MT |
|||||||
9861-xxx | 1/4" - 2" | ||||||
Plug, MT |
|||||||
9850-xxx | 1/4" - 4" | ||||||
Reducer Bushing, MT x T |
|||||||
9839-xxx | 3/8" x 1/4" | 1/2" x 1/4" | 1/2" x 3/8" | ||||
3/4" x 3/8" | 3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" | ||||
1 1/4" x 1" | 1 1/2" x 1/2" | 1 1/2" x 3/4" | 1 1/2" x 1" | ||||
1 1/2" x 1 1/4" | 2" x 3/4" | 2" x 1" | 2" x 1 1/4" | ||||
2" x 1 1/2" | 3" x 2" | 4" x 3" | |||||
Reducer Bushing, Spg x T |
|||||||
9838-xxx | 3/8" x 1/4" | 1/2" x 1/4" | 1/2" x 3/8" | ||||
3/4" x 1/4" | 3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" | ||||
1 1/4" x 1/2" | 1 1/4" x 3/4" | 1 1/4" x 1" | 1 1/2" x 1/2" | ||||
1 1/2" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" | 2" x 1/2" | ||||
2" x 3/4" | 2" x 1" | 2" x 1 1/4" | 2" x 1 1/2" | ||||
2 1/2" x 1 1/2" | 2 1/2" x 2" | 3" x 2" | 4" x 2" | ||||
4" x 3" | |||||||
Reducer Coupling, T x T |
|||||||
9830-xxx | 1/2" x 1/4" | 1/2" x 3/8" | 3/4" x 1/2" | ||||
1" x 1/2" | 1" x 3/4" | 1 1/2" x 1" | |||||
Tee, T x T x T |
|||||||
9805-xxx | 1/4" - 12" | ||||||
*** -xxx Suffix designates nominal size +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Fittings@ *** +++ [G] |
CPVC |
SeaCor® |
ASTM F439 |
||||
45° Ell, S x S |
|||||||
9817-xxx | 1/4" - 12" | ||||||
90° Ell, S x S |
|||||||
9806-xxx | 1/4" - 12" | ||||||
Cap, S |
|||||||
9847-xxx | 3/8" - 12" | ||||||
Coupling, S x S |
|||||||
9829-xxx | 1/4" - 12" | ||||||
Reducer Bushing, Spg x S |
|||||||
9837-xxx | 1/2" x 1/4" | 1/2" x 3/8" | 3/4" x 1/2" | ||||
1" x 1/2" | 1" x 3/4" | 1 1/4" x 1/2" | 1 1/4" x 3/4" | ||||
1 1/4" x 1" | 1 1/2" x 1/2" | 1 1/2" x 3/4" | 1 1/2" x 1" | ||||
1 1/2" x 1 1/4" | 2" x 1/2" | 2" x 3/4" | 2" x 1" | ||||
2" x 1 1/4" | 2" x 1 1/2" | 2 1/2" x 1 1/2" | 2 1/2" x 2" | ||||
3" x 1 1/2" | 3" x 2" | 3" x 2 1/2" | 4" x 2" | ||||
4" x 3" | 6" x 4" | 8" x 6" | 10" x 6" | ||||
Reducer Coupling, S x S |
|||||||
9829-xxx | 1/2" x 3/8" | 3/4" x 1/2" | 1" x 1/2" | ||||
1" x 3/4" | 1 1/4" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" | ||||
2" x 1" | 2" x 1 1/4" | 2" x 1 1/2" | 2 1/2" x 1 1/2" | ||||
3" x 2" | 4" x 3" | 6" x 4" | 8" x 6" | ||||
Reducing Tee, S x S x S |
|||||||
9801-xxx | 3/4" x 3/4" x 1/2" | 1" x 1" x 1/2" | 1" x 1" x 3/4" | ||||
1 1/4" x 1 1/4" x 1" | 1 1/2" x 1 1/2" x 3/4" | 1 1/2" x 1 1/2" x 1" | 1 1/2" x 1 1/2" x 1 1/4" | ||||
1 1/2" x 1 1/2" x 1 1/2" | 2" x 2" x 1/2" | 2" x 2" x 3/4" | 2" x 2" x 1" | ||||
2" x 2" x 1 1/2" | 2 1/2" x 2 1/2" x 2" | 3" x 3" x 1 1/2" | 3" x 3" x 2" | ||||
4" x 4" x 2" | 4" x 4" x 3" | 6" x 4" | 8" x 8" x 6" | ||||
Tee, S x S x S |
|||||||
9801-xxx | 1/4" - 12" | ||||||
@ Fittings or systems to be installed in accordance with the manufacturer's instructions, ASTM Standard and latest edition of Uniform Plumbing Code. *** -xxx Suffix designates nominal size +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Pipe¢ +++ [G] |
CPVC 4120 |
SeaCor® |
CSA B137.6 |
||||
1 1/4" - 2 1/2" Sch 40 | |||||||
1 1/4" - 2 1/2" Sch 80 | |||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Fittings# +++ |
CPVC |
SeaCor® |
ASTM F1970 |
||||
1/2 - 1" 90DEG Drop Ear CPVC 80 Transition (SXFPT) | |||||||
1/2" - 2" Female Adapter Sch 80 | |||||||
1/2" - 2" Male Adapter Sch 80 | |||||||
# Product tested for use in 73°F with a rated pressure of 150 psi. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). |
|||||||
Fittings# +++ |
CPVC |
SeaCor® |
CSA B137.6 |
||||
1/2 - 1" 90DEG Drop Ear CPVC 80 Transition (SXFPT) | |||||||
1/2" - 2" Female Adapter Sch 80 | |||||||
1/2" - 2" Male Adapter Sch 80 | |||||||
# Product tested for use in 73°F with a rated pressure of 150 psi. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). |
|||||||
Pipe+++ [G] |
CPVC 4120 |
+GF+ Uponor ChlorFIT® |
ASTM F441 |
||||
1/4" - 12" Sch 80 | |||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Pipe¢ +++ [G] |
CPVC 4120 |
+GF+ Uponor ChlorFIT® |
CSA B137.6 |
||||
1 1/4" - 2 1/2" Sch 80 | |||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Fittings*** +++ [G] |
CPVC |
+GF+ Uponor ChlorFIT® |
ASTM F437 |
||||
Tee, T x T x T |
|||||||
9805-xxx | 1/4" - 12" | ||||||
90° Ell, T x T |
|||||||
9808-xxx | 1/4" - 12" | ||||||
90° Ell, S x FPT |
|||||||
9807-XXX | 1/2" - 1" | ||||||
45° Ell, T x T |
|||||||
9819-xxx | 1/4" - 12" | ||||||
Coupling, T x T |
|||||||
9830-xxx | 1/4" - 4" | ||||||
Reducer Coupling, T x T |
|||||||
9830-xxx | 1/2" x 1/4" | 1/2" x 3/8" | 3/4" x 1/2" | ||||
1" x 1/2" | 1" x 3/4" | 1 1/2" x 1" | |||||
Female Adapter, S x T |
|||||||
9835-xxx | 1/4" - 4" | ||||||
Male Adapter, S x MT |
|||||||
9836-xxx | 1/2" - 4" | ||||||
Reducer Bushing, Spg x T |
|||||||
9838-xxx | 3/8" x 1/4" | 1/2" x 1/4" | 1/2" x 3/8" | ||||
3/4" x 1/4" | 3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" | ||||
1 1/4" x 1/2" | 1 1/4" x 3/4" | 1 1/4" x 1" | 1 1/2" x 1/2" | ||||
1 1/2" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" | 2" x 1/2" | ||||
2" x 3/4" | 2" x 1" | 2" x 1 1/4" | 2" x 1 1/2" | ||||
2 1/2" x 1 1/2" | 2 1/2" x 2" | 3" x 2" | 4" x 2" | ||||
4" x 3" | |||||||
Reducer Bushing, MT x T |
|||||||
9839-xxx | 3/8" x 1/4" | 1/2" x 1/4" | 1/2" x 3/8" | ||||
3/4" x 3/8" | 3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" | ||||
1 1/4" x 1" | 1 1/2" x 1/2" | 1 1/2" x 3/4" | 1 1/2" x 1" | ||||
1 1/2" x 1 1/4" | 2" x 3/4" | 2" x 1" | 2" x 1 1/4" | ||||
2" x 1 1/2" | 3" x 2" | 4" x 3" | |||||
Cap, T |
|||||||
9848-xxx | 1/4" - 4" | ||||||
Plug, MT |
|||||||
9850-xxx | 1/4" - 4" | ||||||
Nipple, MT x MT |
|||||||
9861-xxx | 1/4" - 2" | ||||||
*** -xxx Suffix designates nominal size +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Fittings@ *** +++ [G] |
CPVC |
+GF+ Uponor ChlorFIT® |
ASTM F439 |
||||
Tee, S x S x S |
|||||||
9801-xxx | 1/4" - 12" | ||||||
Reducing Tee, S x S x S |
|||||||
9801-xxx | 3/4" x 3/4" x 1/2" | 1" x 1" x 1/2" | 1" x 1" x 3/4" | ||||
1 1/4" x 1 1/4" x 1" | 1 1/2" x 1 1/2" x 3/4" | 1 1/2" x 1 1/2" x 1" | 1 1/2" x 1 1/2" x 1 1/4" | ||||
1 1/2" x 1 1/2" x 1 1/2" | 2" x 2" x 1/2" | 2" x 2" x 3/4" | 2" x 2" x 1" | ||||
2" x 2" x 1 1/2" | 2 1/2" x 2 1/2" x 2" | 3" x 3" x 1 1/2" | 3" x 3" x 2" | ||||
4" x 4" x 2" | 4" x 4" x 3" | 6" x 4" | 8" x 8" x 6" | ||||
90° Ell, S x S |
|||||||
9806-xxx | 1/4" - 12" | ||||||
45° Ell, S x S |
|||||||
9817-xxx | 1/4" - 12" | ||||||
Coupling, S x S |
|||||||
9829-xxx | 1/4" - 12" | ||||||
Reducer Coupling, S x S |
|||||||
9829-xxx | 1/2" x 3/8" | 3/4" x 1/2" | 1" x 1/2" | ||||
1" x 3/4" | 1 1/4" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" | ||||
2" x 1" | 2" x 1 1/4" | 2" x 1 1/2" | 2 1/2" x 1 1/2" | ||||
3" x 2" | 4" x 3" | 6" x 4" | 8" x 6" | ||||
Reducer Bushing, Spg x S |
|||||||
9837-xxx | 1/2" x 1/4" | 1/2" x 3/8" | 3/4" x 1/2" | ||||
1" x 1/2" | 1" x 3/4" | 1 1/4" x 1/2" | 1 1/4" x 3/4" | ||||
1 1/4" x 1" | 1 1/2" x 1/2" | 1 1/2" x 3/4" | 1 1/2" x 1" | ||||
1 1/2" x 1 1/4" | 2" x 1/2" | 2" x 3/4" | 2" x 1" | ||||
2" x 1 1/4" | 2" x 1 1/2" | 2 1/2" x 1 1/2" | 2 1/2" x 2" | ||||
3" x 1 1/2" | 3" x 2" | 3" x 2 1/2" | 4" x 2" | ||||
4" x 3" | 6" x 4" | 8" x 6" | 10" x 6" | ||||
10" x 8" | 12" x 10" | ||||||
Cap, S |
|||||||
9847-xxx | 3/8" - 12" | ||||||
@ Fittings or systems to be installed in accordance with the manufacturer's instructions, ASTM Standard and latest edition of Uniform Plumbing Code. *** -xxx Suffix designates nominal size +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
|||||||
Fittings# +++ |
CPVC |
+GF+ Uponor ChlorFIT® |
ASTM F1970 |
||||
1/2 - 1" 90DEG Drop Ear CPVC 80 Transition (SXFPT) | |||||||
1/2" - 2" Female Adapter Sch 80 | |||||||
1/2" - 2" Male Adapter Sch 80 | |||||||
# Product tested for use in 73°F with a rated pressure of 150 psi. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). |
|||||||
Fittings# ¢ +++ |
CPVC |
+GF+ Uponor ChlorFIT® |
CSA B137.6 |
||||
1/2 - 1" 90DEG Drop Ear CPVC 80 Transition (SXFPT) | |||||||
1/2" - 2" Female Adapter Sch 80 | |||||||
1/2" - 2" Male Adapter Sch 80 | |||||||
# Product tested for use in 73°F with a rated pressure of 150 psi. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). |
% CPVC High PSI/Temp Flange Kit (S) ## All products tested for use in 73F as per the specific rated pressures per size
Facility : Bakersfield, CA
Drain, Waste, and Vent - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard | |||
Pipe* |
PVC |
+GF+ Harvel® Industrial PLUS |
ASTM D2665 |
|||
1 1/4" - 24" Sch 40 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. |
||||||
Pipe* |
PVC |
+GF+ HARVEL PVC |
ASTM D2665 |
|||
1 1/4" - 24" Sch 40 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. |
Potable Water - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard | |||
Pipe* + [G] |
PVC |
+GF+ HARVEL PVC |
ASTM D1785 |
|||
1/8" - 24" Sch 40 | ||||||
1/8" - 24" Sch 80 | ||||||
1/2" - 8" Sch 120 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe* + [G] |
PVC |
+GF+ Harvel® Industrial |
ASTM D1785 |
|||
1/8" - 24" Sch 40 | ||||||
1/8" - 24" Sch 80 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe* + [G] |
PVC |
+GF+ Harvel® Industrial PLUS |
ASTM D1785 |
|||
1/8" - 24" Sch 40 | ||||||
1/8" - 24" Sch 80 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe* + [G] |
PVC |
![]() |
ASTM D1785 |
|||
1/2" - 8" Sch 120 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe* + [G] |
PVC |
+GF+ HARVEL PVC |
ASTM D2241 |
|||
1/2" SDR 13.5 | ||||||
3/4" - 10" SDR 21 | ||||||
1" - 24" SDR 26 | ||||||
18" SDR 41 | ||||||
20" SDR 41 | ||||||
24" SDR 41 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe* + [G] |
PVC |
![]() |
ASTM D2241 |
|||
1/2" SDR 13.5 | ||||||
3/4" - 10" SDR 21 | ||||||
1" - 24" SDR 26 | ||||||
18" SDR 41 | ||||||
20" SDR 41 | ||||||
24" SDR 41 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+ ¢ [G] |
PVC |
+GF+ Harvel® Industrial |
CSA B137.3 |
|||
1/2" - 20" Sch 40 | ||||||
1/2" - 24" Sch 80 | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+ ¢ [G] |
PVC |
+GF+ Harvel® Industrial PLUS |
CSA B137.3 |
|||
1/2" - 20" Sch 40 | ||||||
1/2" - 24" Sch 80 | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+ ¢ [G] |
PVC |
+GF+ HARVEL PVC |
CSA B137.3 |
|||
1/2" - 24" Sch 40 | ||||||
1/2" - 24" Sch 80 | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+ ¢ [G] |
PVC |
![]() |
CSA B137.3 |
|||
1/2" - 24" Sch 40 | ||||||
1/2" - 24" Sch 80 | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
ChlorFIT® |
ASTM F441 |
|||
1/4" - 24" Sch 80 | ||||||
1/4" - 24" Sch 40 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
+GF+ HARVEL CPVC |
ASTM F441 |
|||
1/4" - 24" Sch 40 | ||||||
1/4" - 24" Sch 80 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
+GF+ Uponor ChlorFIT® |
ASTM F441 |
|||
1/4" - 24" Sch 80 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
![]() |
ASTM F441 |
|||
1/4" - 24" Sch 40 | ||||||
1/4" - 24" Sch 80 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
SeaCor® |
ASTM F441 |
|||
1/4" - 24" Sch 40 | ||||||
1/4" - 24" Sch 80 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
ChlorFIT® |
CSA B137.6 |
|||
3/8" - 2" SDR 11 | ||||||
1 1/4" - 2 1/2" Sch 80 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
+GF+ HARVEL CPVC |
CSA B137.6 |
|||
3/8" - 2" SDR 11 | ||||||
1 1/4" - 2 1/2" Sch 80 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
+GF+ Uponor ChlorFIT® |
CSA B137.6 |
|||
1 1/4" - 2 1/2" Sch 80 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
![]() |
CSA B137.6 |
|||
3/8" - 2" SDR 11 | ||||||
1 1/4 - 2 1/2" Sch 80 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
SeaCor® |
CSA B137.6 |
|||
3/8" - 2" SDR 11 | ||||||
1 1/4" - 2 1/2" Sch 80 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
+GF+ HARVEL BLAZEMASTER® |
ASTM F442 |
|||
3/4" - 3" SDR 13.5 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
+GF+ HydroKing Commercial |
ASTM F442 |
|||
2 1/2" - 8" SDR 11 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
![]() |
ASTM F442 |
|||
3/4" - 3" SDR 13.5 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
+GF+ HydroKing Commercial |
CSA B137.6 |
|||
1 1/4" - 2 1/2" Sch 80 | ||||||
2 1/2" - 4" SDR 11 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Facility : Irvine, CA
Drain, Waste, and Vent - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard | |||
Pipe* |
PVC |
+GF+ Harvel® Industrial |
ASTM D2665 |
|||
1 1/4" - 24" Sch 40 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. |
||||||
Pipe* |
PVC |
+GF+ Harvel® Industrial PLUS |
ASTM D2665 |
|||
1 1/4" - 24" Sch 40 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. |
Potable Water - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard | |||
Pipe |
CPVC 4120 |
+GF+ HARVEL CPVC |
ASTM D2846 |
|||
3/8" - 2" SDR 11 | ||||||
Pipe+++ [G] |
CPVC 4120 |
![]() |
SE 8459a |
|||
1/4" - 8" Sch 40 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
+GF+ HARVEL BLAZEMASTER® |
ASTM F442 |
|||
3/4" - 3" SDR 13.5 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe |
CPVC 4120 |
![]() |
ASTM D2846 |
|||
3/8" - 2" SDR 11 | ||||||
Pipe |
CPVC 4120 |
HARVEL CPVC |
ASTM D2846 |
|||
3/8" - 2" SDR 11 | ||||||
Pipe+++ [G] |
CPVC 4120 |
+GF+ Harvel CPVC |
SE 8459a |
|||
1/4" - 8" Sch 40 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
![]() |
SE 8459a |
|||
1/4" - 8" Sch 80 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
+GF+ Harvel CPVC |
SE 8459a |
|||
1/4" - 8" Sch 80 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe* + [G] |
PVC |
+GF+ HARVEL PVC |
ASTM D1785 |
|||
1/8" - 24" Sch 40 | ||||||
1/8" - 24" Sch 80 | ||||||
1/2" - 8" Sch 120 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe* + [G] |
PVC |
![]() |
ASTM D1785 |
|||
1/8" - 24" Sch 40 | ||||||
1/8" - 24" Sch 80 | ||||||
1/2" - 8" Sch 120 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe* + [G] |
PVC |
+GF+ HARVEL PVC |
ASTM D2241 |
|||
1/2" SDR 13.5 | ||||||
3/4" - 10" SDR 21 | ||||||
1"- 24" SDR 26 | ||||||
18" SDR 41 | ||||||
20" SDR 41 | ||||||
24" SDR 41 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe* + [G] |
PVC |
![]() |
ASTM D2241 |
|||
1/2" SDR 13.5 | ||||||
3/4" - 10" SDR 21 | ||||||
1" - 24" SDR 26 | ||||||
18" SDR 41 | ||||||
20" SDR 41 | ||||||
24" SDR 41 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+ ¢ [G] |
PVC |
+GF+ HARVEL PVC |
CSA B137.3 |
|||
1/2" Sch 40 | ||||||
1/2" Sch 80 | ||||||
3/4" Sch 40 | ||||||
3/4" Sch 80 | ||||||
1" Sch 40 | ||||||
1" Sch 80 | ||||||
1 1/4" Sch 40 | ||||||
1 1/4" Sch 80 | ||||||
1 1/2" Sch 40 | ||||||
1 1/2" Sch 80 | ||||||
2" Sch 40 | ||||||
2" Sch 80 | ||||||
2 1/2" Sch 40 | ||||||
2 1/2" Sch 80 | ||||||
3" Sch 40 | ||||||
3" Sch 80 | ||||||
4" Sch 40 | ||||||
4" Sch 80 | ||||||
5" Sch 80 | ||||||
6" Sch 40 | ||||||
6" Sch 80 | ||||||
8" Sch 40 | ||||||
8" Sch 80 | ||||||
10" Sch 80 | ||||||
12" Sch 40 | ||||||
12" Sch 80 | ||||||
14" Sch 40 | ||||||
14" Sch 80 | ||||||
16" Sch 40 | ||||||
16" Sch 80 | ||||||
20" Sch 40 | ||||||
20" Sch 80 | ||||||
24" Sch 80 | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+ ¢ [G] |
PVC |
![]() |
CSA B137.3 |
|||
1/2" Sch 40 | ||||||
1/2" Sch 80 | ||||||
3/4" Sch 40 | ||||||
3/4" Sch 80 | ||||||
1" Sch 40 | ||||||
1" Sch 80 | ||||||
1 1/4" Sch 40 | ||||||
1 1/4" Sch 80 | ||||||
1 1/2" Sch 40 | ||||||
1 1/2" Sch 80 | ||||||
2" Sch 40 | ||||||
2" Sch 80 | ||||||
2 1/2" Sch 40 | ||||||
2 1/2" Sch 80 | ||||||
3" Sch 40 | ||||||
3" Sch 80 | ||||||
4" Sch 40 | ||||||
4" Sch 80 | ||||||
5" Sch 80 | ||||||
6" Sch 40 | ||||||
6" Sch 80 | ||||||
8" Sch 40 | ||||||
8" Sch 80 | ||||||
10" Sch 80 | ||||||
12" Sch 40 | ||||||
12" Sch 80 | ||||||
14" Sch 40 | ||||||
14" Sch 80 | ||||||
16" Sch 40 | ||||||
16" Sch 80 | ||||||
20" Sch 40 | ||||||
20" Sch 80 | ||||||
24" Sch 80 | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe* + [G] |
PVC |
+GF+ Harvel® Industrial |
ASTM D1785 |
|||
1/8" - 24" Sch 40 | ||||||
1/8" - 24" Sch 80 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe* + [G] |
PVC |
+GF+ Harvel® Industrial PLUS |
ASTM D1785 |
|||
1/8" - 24" Sch 40 | ||||||
1/8" - 24" Sch 80 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+ ¢ [G] |
PVC |
+GF+ Harvel® Industrial |
CSA B137.3 |
|||
1/2" - 20" Sch 40 | ||||||
1/2" - 24" Sch 80 | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+ ¢ [G] |
PVC |
+GF+ Harvel® Industrial PLUS |
CSA B137.3 |
|||
1/2" - 20" Sch 40 | ||||||
1/2" - 24" Sch 80 | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
![]() |
ASTM D2846 |
|||
3/8" - 2" SDR 11 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
+GF+ HARVEL CPVC |
CSA B137.6 |
|||
3/8" - 2" SDR 11 | ||||||
1 1/4" - 2 1/2" Sch 80 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
Chlorfit |
ASTM D2846 |
|||
3/8" - 2" SDR 11 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
Chlorfit |
ASTM F442 |
|||
3/4" - 3" SDR 13.5 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
ChlorFIT® |
CSA B137.6 |
|||
3/8" - 2" SDR 11 | ||||||
1 1/4" - 2 1/2" Sch 80 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
ChlorFIT® |
ASTM F441 |
|||
1/4" - 24" Sch 40 | ||||||
1/4" - 24" Sch 80 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
![]() |
CSA B137.6 |
|||
3/8" - 2" SDR 11 | ||||||
1 1/4" - 2 1/2" Sch 80 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
+GF+ HARVEL CPVC |
ASTM F441 |
|||
1/4" - 24" Sch 40 | ||||||
1/4" - 24" Sch 80 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
![]() |
ASTM F441 |
|||
1/4" - 24" Sch 40 | ||||||
1/4" - 24" Sch 80 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
![]() |
ASTM F442 |
|||
3/4" - 3" SDR 13.5 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
+GF+ HydroKing Commercial |
ASTM F442 |
|||
2 1/2" - 8" SDR 11 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
+GF+ HydroKing Commercial |
CSA B137.6 |
|||
1 1/4" - 2 1/2" Sch 80 | ||||||
2 1/2" - 4" SDR 11 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
+GF+ CTS |
ASTM D2846 |
|||
3/8" - 2" SDR 11 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
SeaCor® |
CSA B137.6 |
|||
3/8" - 2" SDR 11 | ||||||
1 1/4" - 2 1/2" Sch 80 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
+GF+ CTS |
CSA B137.6 |
|||
3/8" - 2" SDR 11 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
SeaCor® |
ASTM F441 |
|||
1/4" - 24" Sch 40 | ||||||
1/4" - 24" Sch 80 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Well Casings
Product Type | Material Type | Trade Name | Product Standard | |||
Well Casings** |
PVC |
HARVEL PVC |
ASTM F480 |
|||
2" - 16" Sch 40 | ||||||
2" - 16" Sch 80 | ||||||
2" - 16" SDR 17 | ||||||
2" - 10" SDR 21 | ||||||
4" - 16" SDR 26 | ||||||
** Sockets and gasketed bell-ends are not tested or Certified by NSF International for this production facility. |
||||||
Well Casings** |
PVC |
![]() |
ASTM F480 |
|||
2" - 16" Sch 40 | ||||||
2" - 16" Sch 80 | ||||||
2" - 16" SDR 17 | ||||||
2" - 10" SDR 21 | ||||||
4" - 16" SDR 26 | ||||||
** Sockets and gasketed bell-ends are not tested or Certified by NSF International for this production facility. |
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act.
Facility : Easton, PA
Drain, Waste, and Vent - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard | |||
Pipe* |
PVC |
+GF+ Harvel® Industrial |
ASTM D2665 |
|||
1 1/4" - 24" Sch 40 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. |
||||||
Pipe* |
PVC |
+GF+ Harvel® Industrial PLUS |
ASTM D2665 |
|||
1 1/4" - 24" Sch 40 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. |
Potable Water - Pipe and Fittings
Product Type | Material Type | Trade Name | Product Standard | |||
Pipe* + [G] |
PVC |
+GF+ Harvel® Industrial |
ASTM D1785 |
|||
1/8" - 24" Sch 40 | ||||||
1/8" - 24" Sch 80 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe* + [G] |
PVC |
+GF+ Harvel® Industrial PLUS |
ASTM D1785 |
|||
1/8" - 24" Sch 40 | ||||||
1/8" - 24" Sch 80 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe* + [G] |
PVC |
+GF+ HARVEL PVC |
ASTM D1785 |
|||
1/8" - 24" Sch 40 | ||||||
1/8" - 24" Sch 80 | ||||||
1/2" - 8" Sch 120 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe* + [G] |
PVC |
![]() |
ASTM D1785 |
|||
1/2" - 8" Sch 120 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe* + [G] |
PVC |
+GF+ HARVEL PVC |
ASTM D2241 |
|||
1/2" SDR 13.5 | ||||||
3/4" - 10" SDR 21 | ||||||
1"- 24" SDR 26 | ||||||
18" SDR 41 | ||||||
20" SDR 41 | ||||||
24" SDR 41 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe* + [G] |
PVC |
![]() |
ASTM D2241 |
|||
1/2" SDR 13.5 | ||||||
3/4" - 10" SDR 21 | ||||||
1" - 24" SDR 26 | ||||||
18" SDR 41 | ||||||
20" SDR 41 | ||||||
24" SDR 41 | ||||||
* Sockets and gasketed bell ends are not tested or Listed by NSF International for this production facility. + Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+ ¢ [G] |
PVC |
+GF+ Harvel® Industrial |
CSA B137.3 |
|||
1/2" - 24" Sch 80 | ||||||
1/2" - 20" Sch 40 | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+ ¢ [G] |
PVC |
+GF+ Harvel® Industrial PLUS |
CSA B137.3 |
|||
1/2" - 20" Sch 40 | ||||||
1/2" - 24" Sch 80 | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+ ¢ [G] |
PVC |
+GF+ HARVEL PVC |
CSA B137.3 |
|||
1/2" - 24" Sch 40 | ||||||
1/2" - 24" Sch 80 | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+ ¢ [G] |
PVC |
![]() |
CSA B137.3 |
|||
1/2" - 24" Sch 40 | ||||||
1/2" - 24" Sch 80 | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
+GF+ HydroKing Commercial |
ASTM F442 |
|||
2 1/2" - 8" SDR 11 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
+GF+ HydroKing Commercial |
CSA B137.6 |
|||
1 1/4" - 2 1/2" Sch 80 | ||||||
2 1/2" - 4" SDR 11 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
ChlorFIT® |
ASTM F441 |
|||
1/4" - 24" Sch 40 | ||||||
1/4" - 24" Sch 80 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
+GF+ HARVEL CPVC |
ASTM F441 |
|||
1/4" - 24" Sch 40 | ||||||
1/4" - 24" Sch 80 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
+GF+ Uponor ChlorFIT® |
ASTM F441 |
|||
1/4" - 24" Sch 80 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
![]() |
ASTM F441 |
|||
1/4" - 24" Sch 40 | ||||||
1/4" - 24" Sch 80 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
SeaCor® |
ASTM F441 |
|||
1/4" - 24" Sch 40 | ||||||
1/4" - 24" Sch 80 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe+++ [G] |
CPVC 4120 |
![]() |
ASTM F442 |
|||
3/4" - 3" SDR 13.5 | ||||||
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
ChlorFIT® |
CSA B137.6 |
|||
3/8" - 2" SDR 11 | ||||||
1 1/4" - 2 1/2" Sch 80 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
+GF+ HARVEL CPVC |
CSA B137.6 |
|||
3/8" - 2" SDR 11 | ||||||
1 1/4" - 2 1/2" Sch 80 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
+GF+ Uponor ChlorFIT® |
CSA B137.6 |
|||
1 1/4" - 2 1/2" Sch 80 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
![]() |
CSA B137.6 |
|||
3/8" - 2" SDR 11 | ||||||
1 1/4" - 2 1/2" Sch 80 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Pipe¢ +++ [G] |
CPVC 4120 |
SeaCor® |
CSA B137.6 |
|||
3/8" - 2" SDR 11 | ||||||
1 1/4" - 2 1/2" Sch 80 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. +++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at temperatures up to and including Commercial Hot (180° F). [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Well Casings
Product Type | Material Type | Trade Name | Product Standard | |||
Well Casings** [G] |
PVC |
HARVEL PVC |
ASTM F480 |
|||
2" - 16" Sch 40 | ||||||
2" - 16" Sch 80 | ||||||
2" - 16" SDR 17 | ||||||
2" - 10" SDR 21 | ||||||
4" - 16" SDR 26 | ||||||
** Sockets and gasketed bell-ends are not tested or Certified by NSF International for this production facility. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
||||||
Well Casings** [G] |
PVC |
![]() |
ASTM F480 |
|||
2" - 16" Sch 40 | ||||||
2" - 16" Sch 80 | ||||||
2" - 16" SDR 17 | ||||||
2" - 10" SDR 21 | ||||||
4" - 16" SDR 26 | ||||||
** Sockets and gasketed bell-ends are not tested or Certified by NSF International for this production facility. [G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana state laws and the U.S. Safe Drinking Water Act. |
Number of matching Manufacturers is 1
Number of matching Products is 2917
Processing time was 1 seconds