NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, January 15, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/Plumbing/Listings.asp?Company=38790&Standard=014&
NSF/ANSI 14
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
| REHAU Construction LLC | ![]() |
| 1501 Edwards Ferry Road, N.E. | |
| Leesburg, VA 20176 | |
| United States | |
| 800-247-9445 | |
| 703-777-5255 | |
| Visit this company's website |
Facility : # 1 Cambodia
Fire Sprinkler Pipe and Fitting Systems
| Product Type | Material Type | Trade Name | Product Standard | ||||
Pipe and Fitting System% ** [G] |
MLTPL |
Rehau |
ANSI/CAN/UL 1821 |
||||
|
Reinforcing Rings |
|||||||
| 3/4" (499704) | 1" (499705) | 1 1/4" (499706) | 1 1/2" (499707) | ||||
| 2" (499708) | |||||||
% PEX pipe and fittings are intended for use in multi-purpose piping systems of
residential occupancies as
defined in ANSI/NFPA 13D, “Installation of Sprinkler Systems in One- and Two- Family
Dwellings and
Manufactured Homes"" and the International Residential Code, Section P2904, and are
designed to
withstand a working pressure of not less than 130 psi at 120°F. PEX pipe and fittings
are intended to be
installed in accordance with the requirements specified in the manufacturer’s
installation instructions
and ANSI/NFPA 13D. Protection is intended to be provided for PEX pipe and fittings in
multi-purpose
piping systems unless otherwise stated in this listing and per the installation and
design manual dated
September 11, 2008. The minimum protection should consist of either (1) one layer of
3/8-in. gypsum
wallboard, (2) a suspended membrane ceiling with lay-in panels or tiles having a weight
of not less than
0.35 lbs per sq ft when installed with metallic support grids, OR (3) ½ in plywood. PEX
pipe and
fittings are intended for use in areas where the maximum ambient temperature does not
exceed 120°F.
These pipe and fittings are not intended to be installed in outdoor applications. The
PEX pipe and
fittings are intended for use in wet-pipe systems only and have not been evaluated for
use in dry-pipe
systems. Raupex pipe and fittings may also be installed without protection (exposed) in
accordance with
the limitations specified in this installation and design manual dated September 11,
2008.
** Pipe and fittings Certified as a system using installation and design manual titled
"FIREPEX Residential
Fire Sprinkler
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Facility : # 1 China
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard | ||||
Fittings§ +++ [G] |
Brass |
Rehau |
ASTM F1960 |
||||
|
F1960 Adapter, PEX to CP |
|||||||
| 1/2" x 1/2" (499280) | 1/2" x 3/4" (499281) | 3/4" x 3/4" (499284) | 3/4" x 1" (499285) | ||||
| 3/4" x 1/2" (499282) | 1" x 1" (499290) | 1 1/4" x 1 1/4" (499291) | 1 1/2" x 1 1/2" (499292) | ||||
| 2" x 2" (499293) | |||||||
|
F1960 Adapter, PEX to Copper |
|||||||
| 3/8" x 1/2" Male (499859) | 3/8" x 1/2" Female (499860) | 1/2" x 1/2" Male (499795) | 1/2" x 1/2" Female (499794) | ||||
| 1/2" x 3/4" Male (499790) | 1/2" x 3/4" Female (499793) | 3/4" x 1/2" Male (499792) | 3/4" x 1/2" Female (499275) | ||||
| 5/8" x 3/4" Male (499861) | 5/8" x 3/4" Female (499862) | 3/4" x 3/4" Male (499796) | 3/4" x 3/4" Female (499797) | ||||
| 3/4" x 1" Male (499791) | 3/4" x 1" Female (499798) | 1" x 1" Male (499799) | 1" x 1" Female (499800) | ||||
| 1 1/4" x 1 1/4" Male (499801) | 1 1/4" x 1 1/4" Female (499802) | 1 1/2" x 1 1/2" Male (499803) | 1 1/2" x 1 1/2" Female (499804) | ||||
| 2" x 2" Male (499805) | 2" x 2" Female (499806) | ||||||
|
F1960 Adapter, PEX to FPT |
|||||||
| 1/2" x 1/2" (499821) | 1/2" x 3/4" (499819) | 3/4" x 3/4" (499822) | 3/4" x 1" (499820) | ||||
| 1" x 3/4" (499277) | 1" x 1" (499823) | 1 1/4" x 1 1/4" (499863) | 1 1/2" x 1 1/2" (499864) | ||||
| 2" x 2" (499866) | |||||||
|
F1960 Adapter, PEX to MPT |
|||||||
| 1/2" x 1/2" (499807) | 1/2" x 3/4" (499810) | 3/4" x 3/4" (499808) | 3/4" x 1" (499814) | ||||
| 1" x 3/4" (499809) | 1" x 1" (499815) | 1 1/4" x 1 1/4" (499816) | 1 1/2" x 1 1/2" (499817) | ||||
| 2" x 2" (499818) | |||||||
|
F1960 Coupling |
|||||||
| 3/8" x 3/8" (499716) | 5/8" x 5/8" (499713) | ||||||
|
F1960 Drop Ear Elbow, PEX to FPT |
|||||||
| 1/2" x 1/2" (499789) | 3/4" x 3/4" (499787) | ||||||
|
F1960 Elbow, PEX to CP |
|||||||
| 1/2" x 1/2" (499294) | 3/4" x 3/4" (499279) | ||||||
|
F1960 Elbow, PEX to Copper |
|||||||
| 3/4" x 3/4" Male (499784) | 3/4" x 3/4" Female (499785) | 5/8" x 3/4" Male (499857) | 5/8" x 3/4" Female (499858) | ||||
|
F1960 Elbow, PEX to MPT |
|||||||
| 1/2" x 1/2" (499786) | |||||||
|
F1960 Elbow, PEX to PEX |
|||||||
| 5/8" x 5/8" (499856) | |||||||
|
F1960 LF Brass Adapter |
|||||||
| 1/2" x 1/2" C Female (499794) | 3/4" x 3/4" C Female (499797) | 1" x 1" C Female (499800) | |||||
|
F1960 Plug |
|||||||
| 3/8" (499854) | 5/8" (499278) | ||||||
|
F1960 Stub Elbow |
|||||||
| 1/2" 8" (499298) | 1/2" 8" with mounting plate (499299) | 3/4" 8" with mounting plate (499307) | 3/4" 8"(499364) | ||||
| 1" 8"(499365) | |||||||
|
F1960 Stub Out |
|||||||
| 1/2" 8" Straight(499367) | |||||||
|
F1960 Tee |
|||||||
| 5/8" x 5/8" x 5/8" (499843) | |||||||
|
Sprinkler Flow Through |
|||||||
| 1” F1960 x 1” FPT | |||||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Fittings¢ § +++ [G] |
Brass |
Rehau |
CSA B137.5 |
||||
|
F1960 Adapter, PEX to CP |
|||||||
| 1/2" x 1/2" (499280) | 1/2" x 3/4" (499281) | 3/4" x 3/4" (499284) | 3/4" x 1" (499285) | ||||
| 3/4" x 1/2" (499282) | 1" x 1" (499290) | 1 1/4" x 1 1/4" (499291) | 1 1/2" x 1 1/2" (499292) | ||||
| 2" x 2" (499293) | |||||||
|
F1960 Adapter, PEX to Copper |
|||||||
| 3/8" x 1/2" Male (499859) | 3/8" x 1/2" Female (499860) | 1/2" x 1/2" Male (499795) | 1/2" x 1/2" Female (499794) | ||||
| 1/2" x 3/4" Male (499790) | 1/2" x 3/4" Female (499793) | 3/4" x 1/2" Male (499792) | 3/4" x 1/2" Female (499275) | ||||
| 5/8" x 3/4" Male (499861) | 5/8" x 3/4" Female (499862) | 3/4" x 3/4" Male (499796) | 3/4" x 3/4" Female (499797) | ||||
| 3/4" x 1" Male (499791) | 3/4" x 1" Female (499798) | 1" x 1" Male (499799) | 1" x 1" Female (499800) | ||||
| 1 1/4" x 1 1/4" Male (499801) | 1 1/4" x 1 1/4" Female (499802) | 1 1/2" x 1 1/2" Male (499803) | 1 1/2" x 1 1/2" Female (499804) | ||||
| 2" x 2" Male (499805) | 2" x 2" Female (499806) | ||||||
|
F1960 Adapter, PEX to FPT |
|||||||
| 1/2" x 1/2" (499821) | 1/2" x 3/4" (499819) | 3/4" x 3/4" (499822) | 3/4" x 1" (499820) | ||||
| 1" x 3/4" (499277) | 1" x 1" (499823) | 1 1/4" x 1 1/4" (499863) | 1 1/2" x 1 1/2" (499864) | ||||
| 2" x 2" (499866) | |||||||
|
F1960 Adapter, PEX to MPT |
|||||||
| 1/2" x 1/2" (499807) | 1/2" x 3/4" (499810) | 3/4" x 3/4" (499808) | 3/4" x 1" (499814) | ||||
| 1" x 3/4" (499809) | 1" x 1" (499815) | 1 1/4" x 1 1/4" (499816) | 1 1/2" x 1 1/2" (499817) | ||||
| 2" x 2" (499818) | |||||||
|
F1960 Coupling |
|||||||
| 3/8" x 3/8" (499716) | 5/8" x 5/8" (499713) | ||||||
|
F1960 Drop Ear Elbow, PEX to FPT |
|||||||
| 1/2" x 1/2" (499789) | 3/4" x 3/4" (499787) | ||||||
|
F1960 Elbow, PEX to CP |
|||||||
| 1/2" x 1/2" (499294) | 3/4" x 3/4" (499279) | ||||||
|
F1960 Elbow, PEX to Copper |
|||||||
| 3/4" x 3/4" Male (499784) | 3/4" x 3/4" Female (499785) | 5/8" x 3/4" Male (499857) | 5/8" x 3/4" Female (499858) | ||||
|
F1960 Elbow, PEX to MPT |
|||||||
| 1/2" x 1/2" (499786) | |||||||
|
F1960 Elbow, PEX to PEX |
|||||||
| 5/8" x 5/8" (499856) | |||||||
|
F1960 LF Brass Adapter |
|||||||
| 1/2" x 1/2" C Female (499794) | 3/4" x 3/4" C Female (499797) | 1" x 1" C Female (499800) | |||||
|
F1960 Plug |
|||||||
| 3/8" (499854) | 5/8" (499278) | ||||||
|
F1960 Stub Elbow |
|||||||
| 1/2" 8" (499298) | 1/2" 8" with mounting plate (499299) | 3/4" 8" with mounting plate (499307) | 3/4" 8"(499364) | ||||
| 1" 8"(499365) | |||||||
|
F1960 Stub Out |
|||||||
| 1/2" 8" Straight(499367) | |||||||
|
F1960 Tee |
|||||||
| 5/8" x 5/8" x 5/8" (499843) | |||||||
|
Sprinkler Flow Through |
|||||||
| 1” F1960 x 1” FPT | |||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Fittings§ +++ [G] |
Brass |
REHAU |
ASTM F877 |
||||
|
EVERLOC+ 45 DEG Elbow |
|||||||
| 1 1/2" x 1 1/2" (425021) | 2" x 2" (425022) | ||||||
|
EVERLOC+ Elbow |
|||||||
| 1/2" x 1/2" CU Press x 3/8" CU Female (337006) | 1/2" x 1/2" FPT (317170) | 1/2" x 1/2" MPT (317168) | 5/8" x 5/8" (317163) | ||||
| 3/4" x 1/2" FPT (422004) | 3/4" x 3/4" CM (317166) | 3/4" x 3/4" FPT (422006) | 3/4" x 3/4" MPT (317169) | ||||
| 3/4" x 3/4" MPT (425476) | 1" x 1/2" FPT (422005) | 1" x 1" FPT (422007) | |||||
|
EVERLOC+ Sweat Adapter |
|||||||
| 1/2" x 1/2" Cu Female (317184) | 3/4" x 3/4" Cu Female (317187) | 1" x 1" Cu Female (317191) | |||||
|
EVERLOC+ Tee |
|||||||
| 1/2" x 1/2" MPT (428824) | 3/4" x 3/4" x 1/2" FPT (421744) | 1" x 1" x 1/2" FPT (421878) | 1 1/4" x 1 1/4" x 1/2" (424991) | ||||
| 1 1/4" x 1 1/4" x 3/4" (322832) | 1 1/4" x 1" x 3/4" (424989) | 1 1/2" x 1 1/4" x 1 1/2" (317145) | 1 1/2" x 1" x 3/4" (424992) | ||||
| 1 1/2" x 1 1/4" x 3/4" (425025) | 1 1/2" x 1 1/4" x 1" (317153) | 1 1/2" x 1 1/2" x 1/2" (425024) | 1 1/2" x 1 1/2" x 3/4" (322833) | ||||
| 2" x 1 1/4" x 2" (317146) | 2" x 1 1/2" x 1 1/4" (317161) | 2" x 1 1/2" x 1 1/2" (317155) | 2" x 1 1/2" x 3/4" (424994) | ||||
| 2" x 1 1/2" x 1" (317156) | 2" x 1 1/2" x 2" (317147) | 2" x 2" x 1/2" (424995) | 2" x 2" x 3/4" (322834) | ||||
|
Everloc+ Stub Ell |
|||||||
| 1/2" 8" (418665) | 1/2" 8" with mounting plate (424864) | 3/4" 8" (418668) | 3/4" 8" with mounting plate (329229) | ||||
| 1" 8" (436688) | |||||||
|
Everloc+ Stub Out |
|||||||
| 1/2" 8" Straight (418669) | |||||||
|
Everloc+ Tub/Shower Diverter |
|||||||
| 1/2" (418664) | |||||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Fittings¢ § +++ [G] |
Brass |
REHAU |
CSA B137.5 |
||||
|
EVERLOC+ 45 DEG Elbow |
|||||||
| 2" x 2" (425022) | 1 1/2" x 1 1/2" (425021) | ||||||
|
EVERLOC+ Elbow |
|||||||
| 5/8" x 5/8" (317163) | 3/4" x 3/4" CM (317166) | 1/2" x 1/2" MPT (317168) | 3/4" x 3/4" MPT (317169) | ||||
| 1/2" x 1/2" FPT (317170) | 1/2" x 1/2" CU Press x 3/8" CU Female (337006) | 3/4" x 3/4" FPT (422006) | 1" x 1" FPT (422007) | ||||
| 3/4" x 1/2" FPT (422004) | 1" x 1/2" FPT (422005) | 3/4"x 3/4" MPT (425476) | |||||
|
EVERLOC+ Sweat Adapter |
|||||||
| 1/2" x 1/2" Cu Female (317184) | 3/4" x 3/4" Cu Female (317187) | 1" x 1" Cu Female (317191) | |||||
|
EVERLOC+ Tee |
|||||||
| 1/2" x 1/2" MPT (428824) | 1 1/2" x 1 1/4" x 1 1/2" (317145) | 2" x 1 1/4" x 2" (317146) | 2" x 1 1/2" x 2" (317147) | ||||
| 1 1/2" x 1 1/4" x 1" (317153) | 2" x 1 1/2" x 1 1/2" (317155) | 2" x 1 1/2" x 1" (317156) | 2" x 1 1/2" x 1 1/4" (317161) | ||||
| 11/4" x 1 1/4" x 3/4" (322832) | 1 1/2" x 1 1/2" x 3/4" (322833) | 2" x 2" x 3/4" (322834) | 3/4" x 3/4" x 1/2" FPT (421744) | ||||
| 1" x 1" x 1/2" FPT (421878) | 1 1/4" x 1" x 3/4" (424989) | 1 1/4" x 1 1/4" x 1/2" (424991) | 1 1/2" x 1" x 3/4" (424992) | ||||
| 2" x 1 1/2" x 3/4" (424994) | 2" x 2" x 1/2" (424995) | 1 1/2" x 1 1/2" x 1/2" (425024) | 1 1/2" x 1 1/4" x 3/4" (425025) | ||||
|
Everloc+ Stub Ell |
|||||||
| 1/2" 8" (418665) | 1/2" 8" with mounting plate (424864) | 3/4" 8" (418668) | 3/4" 8" with mounting plate (329229) | ||||
| 1" 8" (436688) | |||||||
|
Everloc+ Stub Out |
|||||||
| 1/2" 8" Straight (418669) | |||||||
|
Everloc+ Tub/Shower Diverter |
|||||||
| 1/2" (418664) | |||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Radiant Floor Heating
| Product Type | Material Type | Trade Name | Product Standard | |||
Brass Manifold Outlet |
MLTPL |
RAUPEX x R-20 |
ASTM F877 |
|||
| 3/8" (267507) | ||||||
| 1/2" (261007) | ||||||
| 5/8" (267557) | ||||||
| 3/4" (267007) | ||||||
Brass Manifold Outlet¢ |
MLTPL |
RAUPEX x R-20 |
CSA B137.5 |
|||
| 3/8" (267507) | ||||||
| 1/2" (261007) | ||||||
| 5/8" (267557) | ||||||
| 3/4" (267007) | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. |
||||||
Nickel Plated Manifold Outlet |
MLTPL |
RAUPEX x R-20 |
ASTM F877 |
|||
| 3/8" (418315) | ||||||
| 1/2" (418317) | ||||||
| 5/8" (418318) | ||||||
| 3/4" (F418319) | ||||||
Nickel Plated Manifold Outlet¢ |
MLTPL |
RAUPEX x R-20 |
CSA B137.5 |
|||
| 3/8" (418315) | ||||||
| 1/2" (418317) | ||||||
| 5/8" (418318) | ||||||
| 3/4" (F418319) | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. |
||||||
Nickel Plated Manifold Outlet |
MLTPL |
F1960 x R- 20 |
ASTM F1960 |
|||
| 3/8" (499661) | ||||||
| 1/2" (499662) | ||||||
| 5/8" (499663) | ||||||
| 3/4" (499664) | ||||||
Nickel Plated Manifold Outlet¢ |
MLTPL |
F1960 x R- 20 |
CSA B137.5 |
|||
| 3/8" (499661) | ||||||
| 1/2" (499662) | ||||||
| 5/8" (499663) | ||||||
| 3/4" (499664) | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. |
||||||
Facility : # 1 Germany
Surface Burning Characteristics of Building Materials
| Product Type | Material Type | Trade Name | Product Standard | |||
Tubing[3] [4] |
PEX |
Raupex® White UV Shield |
CAN/ULC S102.2 |
|||
| 1/2" - 2" | ||||||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+
Fittings as per Rehau installation instructions.
Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].
|
||||||
Tubing[3] [4] |
PEX |
Raupex® Red UV Shield |
CAN/ULC S102.2 |
|||
| 1/2" - 2" | ||||||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+
Fittings as per Rehau installation instructions.
Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].
|
||||||
Tubing* [1] |
PEX |
Municipex® |
ASTM E84 |
|||
| 3/4" - 2" | ||||||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing*** [1] |
PEX |
Municipex® |
ASTM E84 |
|||
| 3/4" - 2" | ||||||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
|
||||||
Tubing[2] [3] |
PEX |
Municipex® |
CAN/ULC S102.2 |
|||
| 3/4" - 2" | ||||||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
|
||||||
Tubing* [1] |
PEX |
Raupex® O2 Barrier |
ASTM E84 |
|||
| 1/2" - 2" | ||||||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing** [1] |
PEX |
Raupex® O2 Barrier |
ASTM E84 |
|||
| <= 1/2" | ||||||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing[3] |
PEX |
Raupex® O2 Barrier |
CAN/ULC S102.2 |
|||
| <= 1/2" | ||||||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
||||||
Tubing[2] [3] |
PEX |
Raupex® O2 Barrier |
CAN/ULC S102.2 |
|||
| 5/8" - 2" | ||||||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
|
||||||
Tubing* [1] |
PEX |
Raupex® |
ASTM E84 |
|||
| 1/2" - 2" | ||||||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing** [1] |
PEX |
Raupex® |
ASTM E84 |
|||
| <= 3/4" | ||||||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing*** [1] |
PEX |
Raupex® |
ASTM E84 |
|||
| 3/4" - 2" | ||||||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
|
||||||
Tubing[3] |
PEX |
Raupex® |
CAN/ULC S102.2 |
|||
| <= 1/2" | ||||||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
||||||
Tubing[2] [3] |
PEX |
Raupex® |
CAN/ULC S102.2 |
|||
| 1/2" - 2" | ||||||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
|
||||||
Tubing* [1] |
PEX |
Raupex® Blue UV Shield |
ASTM E84 |
|||
| 1/2" - 2" | ||||||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing** [1] |
PEX |
Raupex® Blue UV Shield |
ASTM E84 |
|||
| <= 3/4" | ||||||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing*** [1] |
PEX |
Raupex® Blue UV Shield |
ASTM E84 |
|||
| 3/4" - 2" | ||||||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
|
||||||
Tubing[1] ***** |
PEX |
Raupex® Blue UV Shield |
ASTM E84 |
|||
| 1/2" - 2" | ||||||
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
***** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with
Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be
marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
|
||||||
Tubing[3] |
PEX |
Raupex® Blue UV Shield |
CAN/ULC S102.2 |
|||
| <= 1/2" | ||||||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
||||||
Tubing[2] [3] |
PEX |
Raupex® Blue UV Shield |
CAN/ULC S102.2 |
|||
| 1/2" - 2" | ||||||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
|
||||||
Tubing* [1] |
PEX |
Raupex® Red UV Shield |
ASTM E84 |
|||
| 1/2" - 2" | ||||||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing[3] [4] |
PEX |
Raupex® Blue UV Shield |
CAN/ULC S102.2 |
|||
| 1/2" - 2" | ||||||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+
Fittings as per Rehau installation instructions.
Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].
|
||||||
Tubing** [1] |
PEX |
Raupex® Red UV Shield |
ASTM E84 |
|||
| <= 3/4" | ||||||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing*** [1] |
PEX |
Raupex® Red UV Shield |
ASTM E84 |
|||
| 3/4" - 2" | ||||||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
|
||||||
Tubing[1] ***** |
PEX |
Raupex® Red UV Shield |
ASTM E84 |
|||
| 1/2" - 2" | ||||||
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
***** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with
Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be
marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
|
||||||
Tubing[3] |
PEX |
Raupex® Red UV Shield |
CAN/ULC S102.2 |
|||
| <= 1/2" | ||||||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
||||||
Tubing[2] [3] |
PEX |
Raupex® Red UV Shield |
CAN/ULC S102.2 |
|||
| 1/2" - 2" | ||||||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
|
||||||
Tubing* [1] |
PEX |
Raupex® White UV Shield |
ASTM E84 |
|||
| 1/2" - 2" | ||||||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing** [1] |
PEX |
Raupex® White UV Shield |
ASTM E84 |
|||
| <= 3/4" | ||||||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing*** [1] |
PEX |
Raupex® White UV Shield |
ASTM E84 |
|||
| 3/4" - 2" | ||||||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
|
||||||
Tubing[1] ***** |
PEX |
Raupex® White UV Shield |
ASTM E84 |
|||
| 1/2" - 2" | ||||||
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
***** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with
Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be
marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
|
||||||
Tubing[3] |
PEX |
Raupex® White UV Shield |
CAN/ULC S102.2 |
|||
| <= 1/2" | ||||||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
||||||
Tubing[2] [3] |
PEX |
Raupex® White UV Shield |
CAN/ULC S102.2 |
|||
| 1/2" - 2" | ||||||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
|
||||||
Tubing[2] [3] |
PEX |
RAUGEO |
CAN/ULC S102.2 |
|||
| 1/2" - 2" | ||||||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
|
||||||
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard | ||||
Pipe* ^ +++ [G] |
PEX 3306 |
MUNICIPEX |
ASTM F876/F877 |
||||
| 1/2" - 2" SDR 9 | |||||||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe* ^ +++ [G] |
PEX 3306 |
MUNICIPEX |
AWWA C904 |
||||
| 1/2" - 2" SDR 9 | |||||||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe& * ^ ¢ § +++ [G] |
PEX |
MUNICIPEX |
CSA B137.5 |
||||
| 1/2" - 2" SDR 9 | |||||||
& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): AWWA C800.
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe* ^ § $$ +++ [G] |
PEX 3306 |
RAUPEX® Blue UV-Shield |
ASTM F876/F877 |
||||
| 3/8" - 2" SDR 9 | |||||||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe% * ^ ¢ § $$ +++ [G] |
PEX |
RAUPEX® Blue UV-Shield |
CSA B137.5 |
||||
| 3/8" - 2" SDR 9 | |||||||
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F877,
F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe* ^ § $$ +++ [G] |
PEX 3306 |
RAUPEX Red UV-Shield |
ASTM F876/F877 |
||||
| 3/8" - 2" SDR 9 | |||||||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe% * ^ ¢ § $$ +++ [G] |
PEX |
RAUPEX Red UV-Shield |
CSA B137.5 |
||||
| 3/8" - 2" SDR 9 | |||||||
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F877,
F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe* ^ § $$ +++ [G] |
PEX 3306 |
RAUPEX White UV-Shield |
ASTM F876/F877 |
||||
| 3/8" - 2" SDR 9 | |||||||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe% * ^ ¢ § $$ +++ [G] |
PEX |
RAUPEX White UV-Shield |
CSA B137.5 |
||||
| 3/8" - 2" SDR 9 | |||||||
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F877,
F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Fittings¢ § +++ |
PPSU |
Rehau |
ASTM F877 |
||||
|
EVERLOC+P Coupling |
|||||||
| 1/2" x 1/2" (104824) | 3/4" x 1/2" (104830) | 3/4" x 3/4" (104825) | 1" x 3/4" (104831) | ||||
| 1" x 1" (104826) | 1 1/4" x 1" (104832) | 1 1/4" x 1 1/4" (104827) | 1 1/2" x 1" (104833) | ||||
| 1 1/2" x 1 1/2" (104828) | 2" x 2" (104829) | ||||||
|
EVERLOC+P Elbow |
|||||||
| 1/2" x 1/2" (104859) | 3/4" x 3/4" (104860) | 1" x 1" (104861) | 1 1/4" x 1 1/4" (104862) | ||||
| 1 1/2" x 1 1/2" (104863) | 2" x 2" (104864) | ||||||
|
EVERLOC+P Manifolds |
|||||||
| Mfld CE 3/4” x (3)1/2"Out (104867) | Mfld CE 3/4” x (4)1/2"Out (104868) | Mfld FT (2)3/4In, (2)1/2Out (104869) | Mfld FT (2)3/4In, (3)1/2" Out (104870) | ||||
| Mfld FT (2)3/4In, (4)1/2Out (104871) | Mfld EFT (2)3/4In, (3)1/2" Out (104872) | Mfld EFT (2)3/4In, (4)1/2" Out (104873) | EVERLOC+P Mfld CE 3/4'' x (6)1/2''Out (108807) | ||||
| EVERLOC+P Mfld CE 1",x (4)1/2Out (108808) | EVERLOC+P Mfld CE 1" x , (6)1/2Out (108809) | EVERLOC+ P Mfld FT (2) 3/4”, (2) ½” Out, + (1) ½” Out (433900) | EVERLOC+ P Mfld FT (2) 3/4”, (2) ½” Out, + (2) ½” Out (433894) | ||||
| EVERLOC+ P Mfld FT (2) 3/4”, (3) ½” Out, + (3) ½” Out (433896) | EVERLOC+P Mfld CE (2)3/4" In,(6)1/2Out (108804) | EVERLOC+ P Mfld FT (2) 1”, (3) ½” Out (433897) | EVERLOC+ P Mfld FT (2) 1”, (4) ½” Out (433903) | ||||
| EVERLOC+P Mfld CE (2) 1" In,(6)1/2Out (108805) | EVERLOC+ P Mfld CE 3/4”, (2) ½” Out, + (1) ½” out (433898) | EVERLOC+ P Mfld CE 3/4”, (2) ½” Out, + (2) ½” out (433899) | EVERLOC+ P Mfld FT 1” x ¾”, (3) ½” Out (433904) | ||||
| EVERLOC+P Mfld CE 1" x 3/4" In x (4) 1/2" Out (108806) | EVERLOC+ P Mfld FT 1” x ¾”, (6) ½” Out (433906) | ||||||
|
EVERLOC+P Plug |
|||||||
| 1/2" (104856) | 3/4" (104857) | 1" (104858) | |||||
|
EVERLOC+P Tee |
|||||||
| 1/2" x 1/2" x 1/2" (104835) | 1/2" x 1/2" x 3/4" (104854) | 3/4" x 1/2" x 1/2" (104851) | 3/4" x 1/2" x 3/4" (104841) | ||||
| 3/4" x 3/4" x 1/2" (104844) | 3/4" x 3/4" x 3/4" (104836) | 3/4" x 3/4" x 1" (104855) | 1" x 3/4" x 3/4" (104852) | ||||
| 1" x 3/4" x 1" (104842) | 1" x 1" x 1/2" (104846) | 1" x 1" x 3/4" (104845) | 1" x 1" x 1" (104837) | ||||
| 1 1/4" x 1" x 1" (104853) | 1 1/4" x 1 1/4" x 1" (104847) | 1 1/4" x 1 1/4" x 1 1/4" (104838) | 1 1/2" x 1 1/2" x 1" (104848) | ||||
| 1 1/2" x 1 1/2" x 1 1/2" (104839) | 2" x 2" x 1" (104849) | 2" x 2" x 2" (104840) | |||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
|
|||||||
Fittings¢ § +++ |
PPSU |
Rehau |
CSA B137.5 |
||||
|
EVERLOC+P Coupling |
|||||||
| 1/2" x 1/2" (104824) | 3/4" x 1/2" (104830) | 3/4" x 3/4" (104825) | 1" x 3/4" (104831) | ||||
| 1" x 1" (104826) | 1 1/4" x 1" (104832) | 1 1/4" x 1 1/4" (104827) | 1 1/2" x 1" (104833) | ||||
| 1 1/2" x 1 1/2" (104828) | 2" x 2" (104829) | ||||||
|
EVERLOC+P Elbow |
|||||||
| 1/2" x 1/2" (104859) | 3/4" x 3/4" (104860) | 1" x 1" (104861) | 1 1/4" x 1 1/4" (104862) | ||||
| 1 1/2" x 1 1/2" (104863) | 2" x 2" (104864) | ||||||
|
EVERLOC+P Manifolds |
|||||||
| Mfld CE 3/4” x (3)1/2"Out (104867) | Mfld CE 3/4” x (4)1/2"Out (104868) | Mfld FT (2)3/4In, (2)1/2Out (104869) | Mfld FT (2)3/4In, (3)1/2Out (104870) | ||||
| Mfld FT (2)3/4In, (4)1/2Out (104871) | Mfld EFT (2)3/4In, (3)1/2Out (104872) | Mfld EFT (2)3/4In, (4)1/2Out (104873) | EVERLOC+P Mfld CE 3/4'' x (6)1/2''Out (108807) | ||||
| EVERLOC+P Mfld CE 1",x (4)1/2Out (108808) | EVERLOC+P Mfld CE 1" x , (6)1/2Out (108809) | EVERLOC+ P Mfld FT (2) 3/4”, (2) ½” Out, + (1) ½” Out (433900) | EVERLOC+ P Mfld FT (2) 3/4”, (2) ½” Out, + (2) ½” Out (433894) | ||||
| EVERLOC+ P Mfld FT (2) 3/4”, (3) ½” Out, + (3) ½” Out (433896) | EVERLOC+P Mfld CE (2)3/4" In,(6)1/2Out (108804) | EVERLOC+ P Mfld FT (2) 1”, (3) ½” Out (433897) | EVERLOC+ P Mfld FT (2) 1”, (4) ½” Out (433903) | ||||
| EVERLOC+P Mfld CE (2) 1" In,(6)1/2Out (108805) | EVERLOC+ P Mfld CE 3/4”, (2) ½” Out, + (1) ½” out (433898) | EVERLOC+ P Mfld CE 3/4”, (2) ½" Out, + (2) ½" out (433899) | EVERLOC+ P Mfld FT 1” x ¾”, (3) ½” Out (433904) | ||||
| EVERLOC+P Mfld CE 1" x 3/4" In x (4) 1/2" Out (108806) | EVERLOC+ P Mfld FT 1” x ¾”, (6) ½” Out (433906) | ||||||
|
EVERLOC+P Plug |
|||||||
| 1/2" (104856) | 3/4" (104857) | 1" (104858) | |||||
|
EVERLOC+P Tee |
|||||||
| 1/2" x 1/2" x 1/2" (104835) | 1/2" x 1/2" x 3/4" (104854) | 3/4" x 1/2" x 1/2" (104851) | 3/4" x 1/2" x 3/4" (104841) | ||||
| 3/4" x 3/4" x 1/2" (104844) | 3/4" x 3/4" x 3/4" (104836) | 3/4" x 3/4" x 1" (104855) | 1" x 3/4" x 3/4" (104852) | ||||
| 1" x 3/4" x 1" (104842) | 1" x 1" x 1/2" (104846) | 1" x 1" x 3/4" (104845) | 1" x 1" x 1" (104837) | ||||
| 1 1/4" x 1" x 1" (104853) | 1 1/4" x 1 1/4" x 1" (104847) | 1 1/4" x 1 1/4" x 1 1/4" (104838) | 1 1/2" x 1 1/2" x 1" (104848) | ||||
| 1 1/2" x 1 1/2" x 1 1/2" (104839) | 2" x 2" x 1" (104849) | 2" x 2" x 2" (104840) | |||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
|
|||||||
Radiant Floor Heating
| Product Type | Material Type | Trade Name | Product Standard | |||
Pipe$ * ^ § |
PEX 3006 |
RAUPEX® |
ASTM F876/F877 |
|||
| 3/8" - 2" SDR 9 | ||||||
$ Non-barrier pipe. * Accepted by NSF for use in residential and commercial construction, including manufactured housing. ^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with ASTM F2023. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Pipe$ % * § |
PEX 3006 |
RAUPEX® |
CSA B137.5 |
|||
| 3/8" - 2" SDR 9 | ||||||
$ Non-barrier pipe. % Tubing certified against CSA B137.5 shall include the standard designation(s) of the fitting system(s) for which the tubing is recommended by the manufacturer, and shall be marked, as applicable, with the following fitting system designation(s): ASTM F877, F1807, F1960, F2080 and F2159. * Accepted by NSF for use in residential and commercial construction, including manufactured housing. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Pipe* ¥ |
PEX 0306 |
Raupex Black UV Shield |
ASTM F876/F877 |
|||
| 3/8" - 2" | ||||||
* Accepted by NSF for use in residential and commercial construction, including manufactured housing. ¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Mechanical Code™. |
||||||
Pipe% * ¢ ¥ |
PEX |
Raupex Black UV Shield |
CSA B137.5 |
|||
| 3/8" - 2" | ||||||
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the fitting system(s) for which the tubing is recommended by the manufacturer, and shall be marked, as applicable, with the following fitting system designation(s): ASTM F877, F1807, F1960, F2080 and F2159. * Accepted by NSF for use in residential and commercial construction, including manufactured housing. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. ¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Mechanical Code™. |
||||||
Facility : # 1 Taiwan
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard | ||||
Fittings¢ § +++ [G] |
MLTPL |
REHAU |
ASTM D2846 |
||||
|
EVERLOC+ x CPVC Transition Fitting |
|||||||
| 1/2 x 1/2 Socket CPVC (455700) | 1/2 x 1/2 Spigot CPVC (455701) | 3/4 x 3/4 Socket CPVC (455702) | 3/4 x 3/4 Spigot CPVC (455703) | ||||
| 1 x 1 Spigot CPVC (455704) | 1 x 1 Socket CPVC (455705) | 1 1/4x1 1/4 SPIG CPVC (455706) | 1 1/4x1 1/4 SOC CPVC (455707) | ||||
| 1 1/2x1 1/2 SPIG CPVC (455708) | 1 1/2x1 1/2 SOC CPVC (455709) | 2 x 2 Spigot CPVC (455710) | 2 x 2 Socket CPVC (455711) | ||||
|
F1960 x CPVC Transition Fitting |
|||||||
| 499665 1/2 x 1/2 Spigot CPVC | 499670 3/4 x 3/4 Socket CPVC | 499671 1 x 1 Spigot CPVC | 499672 1 x 1 Socket CPVC | ||||
| 499673 1 1 /4 x 1 1/4 Spigot CPVC | 499674 1 1/4 x 1 1/4 Socket CPVC | 499675 1 1/2 x 1 1/2 Spigot CPVC | 499677 1 1/2 x 1 1/2 Socket CPVC | ||||
| 499678 2 x 2 Spigot CPVC | 499679 2 x 2 Socket CPVC | 499667 1/2 x 1/2 Socket CPVC | 499669 3/4 x 3/4 Spigot CPVC | ||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Fittings¢ § +++ [G] |
MLTPL |
REHAU |
ASTM F877 |
||||
|
EVERLOC+ x CPVC Transition Fitting |
|||||||
| 1/2 x 1/2 Socket CPVC (455700) | 1/2 x 1/2 Spigot CPVC (455701) | 3/4 x 3/4 Socket CPVC (455702) | 3/4 x 3/4 Spigot CPVC (455703) | ||||
| 1 x 1 Spigot CPVC (455704) | 1 x 1 Socket CPVC (455705) | 1 1/4x1 1/4 SPIG CPVC (455706) | 1 1/4x1 1/4 SOC CPVC (455707) | ||||
| 1 1/2x1 1/2 SPIG CPVC (455708) | 1 1/2x1 1/2 SOC CPVC (455709) | 2 x 2 Spigot CPVC (455710) | 2 x 2 Socket CPVC (455711) | ||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Fittings¢ § +++ [G] |
MLTPL |
REHAU |
CSA B137.5 |
||||
|
EVERLOC+ x CPVC Transition Fitting |
|||||||
| 1/2 x 1/2 Socket CPVC (455700) | 1/2 x 1/2 Spigot CPVC (455701) | 3/4 x 3/4 Socket CPVC (455702) | 3/4 x 3/4 Spigot CPVC (455703) | ||||
| 1 x 1 Spigot CPVC (455704) | 1 x 1 Socket CPVC (455705) | 1 1/4x1 1/4 SPIG CPVC (455706) | 1 1/4x1 1/4 SOC CPVC (455707) | ||||
| 1 1/2x1 1/2 SPIG CPVC (455708) | 1 1/2x1 1/2 SOC CPVC (455709) | 2 x 2 Spigot CPVC (455710) | 2 x 2 Socket CPVC (455711) | ||||
|
F1960 x CPVC Transition Fitting |
|||||||
| 499678 2 x 2 Spigot CPVC | 499665 1/2 x 1/2 Spigot CPVC | 499667 1/2 x 1/2 Socket CPVC | 499669 3/4 x 3/4 Spigot CPVC | ||||
| 499670 3/4 x 3/4 Socket CPVC | 499671 1 x 1 Spigot CPVC | 499672 1 x 1 Socket CPVC | 499673 1 1 /4 x 1 1/4 Spigot CPVC | ||||
| 499674 1 1/4 x 1 1/4 Socket CPVC | 499675 1 1/2 x 1 1/2 Spigot CPVC | 499677 1 1/2 x 1 1/2 Socket CPVC | 499679 2 x 2 Socket CPVC | ||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Fittings¢ § +++ [G] |
MLTPL |
REHAU |
ASTM F1960 |
||||
|
F1960 x CPVC Transition Fitting |
|||||||
| 499667 1/2 x 1/2 Socket CPVC | 499665 1/2 x 1/2 Spigot CPVC | 499679 2 x 2 Socket CPVC | 499678 2 x 2 Spigot CPVC | ||||
| 499677 1 1/2 x 1 1/2 Socket CPVC | 499669 3/4 x 3/4 Spigot CPVC | 499674 1 1/4 x 1 1/4 Socket CPVC | 499673 1 1 /4 x 1 1/4 Spigot CPVC | ||||
| 499672 1 x 1 Socket CPVC | 499671 1 x 1 Spigot CPVC | 499670 3/4 x 3/4 Socket CPVC | 499675 1 1/2 x 1 1/2 Spigot CPVC | ||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Facility : # 2 Taiwan
Fire Sprinkler Pipe and Fitting Systems
| Product Type | Material Type | Trade Name | Product Standard | ||||
Pipe and Fitting System% ** [G] |
PPSU |
REHAU |
ANSI/CAN/UL 1821 |
||||
|
45 Deg, PEX to PEX Elbow |
|||||||
| 45 Deg Elbow 1 1/2 x 1 1/2 in. (499872) | 45 Deg Elbow 2 x 2 in. (499873) | ||||||
|
Branch + Run Reducing Tee |
|||||||
| Tee, 3/4 x 1/2 x 1/2 in. (499754) | Tee, 1 x 3/4 x 3/4 in. (499755) | Tee, 1 1/4 x 1 x 1/2 in. (499852) | Tee, 1 1/4 x 1 x 3/4 in. (499760) | ||||
| Tee, 1 1/4 x 1 x 1 in. (499756) | Tee, 1 1/2 x 1 x 3/4 in. (499761) | Tee, 1 1/2 x 1 x 1 in. (499757) | Tee, 1 1/2 x 1 x 1 1/4 in. (499853) | ||||
| Tee, 1 1/2 x 1 1/4 x 3/4 in. (499763) | Tee, 1 1/2 x 1 1/4 x 1 in. (499762) | Tee, 1 1/2 x 1 1/4 x 1 1/4 in. (499758) | Tee, 2 x 1 1/2 x 1/2 in. (499881) | ||||
| Tee, 2 x 1 1/2 x 3/4 in. (499877) | Tee, 2 x 1 1/2 x 1 in. (499878) | Tee, 2 x 1 1/2 x 1 1/4 in. (499879) | Tee, 2 x 1 1/2 x 1 1/2 in. (499880) | ||||
|
Branch Reducing Tee |
|||||||
| Tee, 3/4 x 3/4 x 1/2 in. (499739) | Tee, 1 x 1 x 1/2 in. (499741) | Tee, 1 x 1 x 3/4 in. (499740) | Tee, 1 1/4 x 1 1/4 x 1/2 in. (499744) | ||||
| Tee, 1 1/4 x 1 1/4 x 3/4 in. (499743) | Tee, 1 1/4 x 1 1/4 x 1 in. (499742) | Tee 1 1/2 x 1 1/2 x 1/2 in. (499876) | Tee, 1 1/2 x 1 1/2 x 3/4 in. (499753) | ||||
| Tee, 1 1/2 x 1 1/2 x 1 in. (499746) | Tee, 1 1/2 x 1 1/2 x 1 1/4 in. (499747) | Tee, 2 x 2 x 1/2 in. (499883) | Tee, 2 x 2 x 3/4 in. (499882) | ||||
| Tee, 2 x 2 x 1 in. (499752) | Tee, 2 x 2 x 1 1/4 in. (499748) | Tee, 2 x 2 x 1 1/2 in. (499749) | |||||
|
Bullhead Tee |
|||||||
| Tee, 1/2 x 1/2 x 3/4 in. (499767) | Tee, 3/4 x 3/4 x 1 in. (499768) | ||||||
|
PEX to PEX Elbow |
|||||||
| Elbow, 3/4 x 1/2 in. (490318) | Elbow, 3/4 x 3/4 in. (499777) | Elbow, 1 x 1 in. (499778) | Elbow, 1 1/4 x 1 1/4 in. (499779) | ||||
| Elbow, 1 1/2 x 1 1/2 in. (499780) | Elbow, 2 x 2 in. (499781) | ||||||
|
Plug |
|||||||
| Plug, 3/4 in. (499771) | Plug, 1 in. (499772) | Plug, 1 1/4 in. (499773) | Plug, 1 1/2 in. (499774) | ||||
| Plug, 2 in. (499775) | |||||||
|
Reducing Coupling |
|||||||
| Coupling, 3/4 x 1/2 in. (499717) | Coupling, 1 x 1/2 in. (490319) | Coupling, 1 x 3/4 in. (499718) | Coupling, 1 1/4 x 3/4 in. (499721) | ||||
| Coupling, 1 1/4 x 1 in. (499719) | Coupling, 1 1/2 x 3/4 in. (499874) | Coupling 1 1/2 x 1 in. (499875) | Coupling, 1 1/2 x 1 1/4 in. (499723) | ||||
| Coupling, 2 x 1 1/2 in. (499724) | |||||||
|
Run Reducing Tee |
|||||||
| Tee, 3/4 x 1/2 x 3/4 in. (499734) | Tee, 1 x 3/4 x 1 in. (499735) | Tee 1 1/4 x 3/4 x 1 1/4 in. (499846) | Tee 1 1/4 x 1 x 1 1/4 in. (499736) | ||||
| Tee, 1 1/2 x 3/4 x 1 1/2 in. (499847) | Tee, 1 1/2 x 1 x 1 1/2 in. (499737) | Tee, 1 1/2 x 1 1/4 x 1 1/2 in. (499848) | Tee, 2 x 1 x 2 in. (499849) | ||||
| Tee, 2 x 1 1/4 x 2 in. (499850) | Tee, 2 x 1 1/2 x 2 in. (499738) | ||||||
|
Straight Coupling |
|||||||
| Coupling, 3/4 x 3/4 in. (499710) | Coupling, 1 x 1 in. (499711) | Coupling, 1 1/4 x 1 1/4 in. (499712) | Coupling, 1 1/2 x 1 1/2 in. (499714) | ||||
| Coupling, 2 x 2 in. (499715) | |||||||
|
Straight Tee |
|||||||
| Tee, 3/4 x 3/4 x 3/4 in. (499729) | Tee, 1 x 1 x 1 in. (499730) | Tee, 1 1/4 x 1 1/4 x 1 1/4 in. (499731) | Tee, 1 1/2 x 1 1/2 x 1 1/2 in. (499732) | ||||
| Tee, 2 x 2 x 2 in. (499733) | |||||||
% PEX pipe and fittings are intended for use in multi-purpose piping systems of
residential occupancies as defined in ANSI/NFPA 13D, “Installation of Sprinkler Systems
in One- and Two- Family Dwellings and Manufactured Homes"" and the International
Residential Code, Section P2904, and are designed to withstand a working pressure of not
less than 130 psi at 120°F. PEX pipe and fittings are intended to be installed in
accordance with the requirements specified in the manufacturer’s installation
instructions and ANSI/NFPA 13D. Protection is intended to be provided for PEX pipe and
fittings in multi-purpose piping systems unless otherwise stated in this listing and per
the installation and design manual dated September 11, 2008. The minimum protection
should consist of either (1) one layer of 3/8-in. gypsum wallboard, (2) a suspended
membrane ceiling with lay-in panels or tiles having a weight of not less than 0.35 lbs
per sq ft when installed with metallic support grids, OR (3) ½ in plywood. PEX pipe and
fittings are intended for use in areas where the maximum ambient temperature does not
exceed 120°F. These pipe and fittings are not intended to be installed in outdoor
applications. The PEX pipe and fittings are intended for use in wet-pipe systems only
and have not been evaluated for use in dry-pipe systems. Raupex pipe and fittings may
also be installed without protection (exposed) in accordance with the limitations
specified in this installation and design manual dated September 11, 2008.
** Pipe and fittings Certified as a system using installation and design manual titled
"FIREPEX Residential
Fire Sprinkler Systems".
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Facility : # 4 USA
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard | ||||
Fittings§ +++ [G] |
Brass |
REHAU |
ASTM F877 |
||||
|
EVERLOC+ LF Adapter |
|||||||
| 1/2" x 1/2" CF (317184) | 1/2" x 1/2" FPT (317173) | 1/2" x 3/4" CF (322835) | 1/2" x 1/2" CM or 3/8" CF (317185) | ||||
| 3/4" x 1/2" CF (325164) | 3/4" x 1/2" CM (325165) | 3/4" x 3/4" CM (317186) | 3/4" x 3/4" CF (317187) | ||||
| 1" x 3/4" MPT (323708) | 1" x 1" CF (317191) | 1-1/4" x 1-1/4" CM (317192) | |||||
|
EVERLOC+ LF Coupling |
|||||||
| 1-1/4" x 3/4" (425026) | 1-1/2" x 3/4" (425028) | 1 1/2" x 1 1/4" (422233) | 2" x 1/2" (425029) | ||||
| 2" x 3/4" (425031) | 2" x 1-1/4" (317140) | 2" x 1-1/2" (317141) | |||||
|
EVERLOC+ LF Elbows |
|||||||
| 1/2" x 1/2" CM or 3/8" CF (317164) | 1/2" (317165) | 1/2" x 1/2" FPT (317170) | 3/4" (317167) | ||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Fittings§ +++ [G] |
Brass |
REHAU |
CSA B137.5 |
||||
|
EVERLOC+ LF Adapter |
|||||||
| 1/2" x 1/2" FPT (317173) | 1/2" x 1/2" CF (317184) | 1/2" x 1/2"CM or 3/8" CF (317185) | 1/2" x 3/4" CF (322835) | ||||
| 3/4" x 1/2" CF (325164) | 3/4" x 1/2" CM (325165) | 3/4" x 3/4" CF (317187) | 3/4" x 3/4" CM (317186) | ||||
| 1" x 3/4" MPT (323708) | 1" x 1" CF (317191) | 1-1/4" x 1-1/4" CM (317192) | |||||
|
EVERLOC+ LF Coupling |
|||||||
| 1-1/4" x 3/4" (425026) | 1-1/2" x 3/4" (425028) | 1 1/2" x 1 1/4" (422233) | 2" x 1/2" (425029) | ||||
| 2" x 3/4" (425031) | 2" x 1-1/4" (317140) | 2" x 1-1/2" (317141) | |||||
|
EVERLOC+ LF Elbows |
|||||||
| 1/2" x 1/2" CM or 3/8" CF (317164) | 1/2" (317165) | 3/4" (317167) | 1/2" x 1/2" FPT (317170) | ||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Facility : # 5 USA
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard | ||||
Fittings§ +++ [G] |
MLTPL |
REHAU |
ASTM F877 |
||||
|
EVERLOC+ LF Adapter |
|||||||
| 3/8" x 1/2"MPT (317174) | 1/2" x 1/2" CP (337007) | 1/2" x 1/2" FPT (317173) | 1/2" x 1/2"MPT (317171) | ||||
| 1/2" x 1/2"CF (317184) | 5/8" x 1/2"MPT (317175) | 5/8" x 3/4"MPT or 1/2"CF (317176) | 3/4" x 1/2" CP (337008) | ||||
| 3/4" x 3/4" CP (337010) | 3/4" x 3/4"MPT (317172) | 3/4" x 3/4"FPT (317182) | 3/4" x 1"MPT (317177) | ||||
| 3/4" x 1"CF (317189) | 3/4" x 3/4" CF (317187) | 1" x 3/4" FPT (329227) | 1" x 1" CP (337011) | ||||
| 1" x 1"MPT (317178) | 1" x 1"FPT (317183) | 1" x 1" CF (317191) | 1" x 1"CM (317190) | ||||
| 1-1/4" x 1-1/4"MPT (317179) | 1-1/4" x 1-1/4"CF (317193) | 1 1/4" x 1 1/4" CP (337012) | 1-1/2" x 1-1/2"CM (317194) | ||||
| 1 1/2" x 1 1/2" CP (337013) | 1-1/2" x 1-1/2"MPT (317180) | 2" x 2"MPT (317181) | 1-1/2" x 2"CM or 1-1/2"CF (317195) | ||||
| 2" x 2"CM (317196) | 2" x 2" CP (337014) | 2" x 2"CF (317197) | |||||
|
EVERLOC+ LF Coupling |
|||||||
| 3/8" x 3/8" (317138) | 5/8" x 5/8" (317142) | 1/2" x 1/2" (318366) | 3/4" x 5/8" (426294) | ||||
| 3/4" x 3/4" (318369) | 1" x 1/2" (426297) | 1" x 1" (318370) | 2" x 1" (317139) | ||||
|
EVERLOC+ LF Manifold Outlet |
|||||||
| 1/2" (326710) | 3/4" (326711) | ||||||
|
EVERLOC+ LF Plug |
|||||||
| 1/2" (318385) | 5/8" (317157) | 1-1/4" (317158) | 1-1/2" (317159) | ||||
| 2" (317160) | |||||||
|
EVERLOC+ Manifold Sweat Adapter |
|||||||
| 3/4" X 1" CF (326712) | 1" X 1" CM (326713) | ||||||
|
EVERLOC+ Swivel |
|||||||
| 1/2" x 1/2" NPS (418463) | 3/4" x 3/4" NPS (418464) | ||||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Fittings§ +++ [G] |
MLTPL |
REHAU |
CSA B137.5 |
||||
|
EVERLOC+ LF Adapter |
|||||||
| 3/8" x 1/2" MPT (317174) | 1/2" x 1/2" CF (317184) | 1/2” x 1/2” CP (337007) | 1/2" x 1/2" FPT (317173) | ||||
| 1/2" x 1/2" MPT (317171) | 5/8" x 1/2" MPT (317175) | 5/8" x 3/4" MPT or 1/2" CF (317176) | 3/4 x 3/4 CF (317187) | ||||
| 3/4” x 3/4” CP (337008) | 3/4” x 3/4” CP (337010) | 3/4" x 3/4" FPT (317182) | 3/4" x 3/4" MPT (317172) | ||||
| 3/4" x 1" CF (317189) | 3/4" x 1" MPT (317177) | 1" x 3/4" FPT (329227) | 1" x 1" CF (317191) | ||||
| 1" x 1" CM (317190) | 1” x 1” CP (337011) | 1" x 1" FPT (317183) | 1" x 1" MPT (317178) | ||||
| 1 1/4" x 1 1/4"CF (317193) | 1 1/4” x 1 1/4” CP (337012) | 1 1/4" x 1 1/4"MPT (317179) | 1 1/2" x 1 1/2"CM (317194) | ||||
| 1 1/2” x 1 1/2” CP (337013) | 1 1/2" x 1 1/2"MPT (317180) | 1 1/2" x 2"CM or 1 1/2"CF (317195) | 2" x 2"CF (317197) | ||||
| 2" x 2"CM (317196) | 2” x 2” CP (337014) | 2" x 2"MPT (317181) | |||||
|
EVERLOC+ LF Coupling |
|||||||
| 3/8" x 3/8" (317138) | 5/8" x 5/8" (317142) | 1/2" x 1/2" (318366) | 3/4" x 5/8" (426294) | ||||
| 3/4" x 3/4" (318369) | 1" x 1/2" (426297) | 1" x 1" (318370) | 2" X 1" (317139) | ||||
|
EVERLOC+ LF Plug |
|||||||
| 1/2" (318385) | 5/8" (317157) | 1-1/4" (317158) | 1-1/2" (317159) | ||||
| 2" (317160) | |||||||
|
EVERLOC+ Manifold Outlet |
|||||||
| 1/2" (326710) | 3/4" (326711) | ||||||
|
EVERLOC+ Manifold Sweat Adapter |
|||||||
| 3/4" X 1" CF (326712) | 1" X 1" CM (326713) | ||||||
|
EVERLOC+ Swivel |
|||||||
| 1/2" x 1/2" NPS (418463) | 3/4" x 3/4" NPS (418464) | ||||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Radiant Floor Heating
| Product Type | Material Type | Trade Name | Product Standard | |||
Brass Manifold Outlet |
MLTPL |
RAUPEX x R-20 |
ASTM F877 |
|||
| 3/8" (267507) | ||||||
| 1/2" (261007) | ||||||
| 5/8" (267557) | ||||||
| 3/4" (267007) | ||||||
Brass Manifold Outlet¢ |
MLTPL |
RAUPEX x R-20 |
CSA B137.5 |
|||
| 3/8" (267507) | ||||||
| 1/2" (261007) | ||||||
| 5/8" (267557) | ||||||
| 3/4" (267007) | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. |
||||||
Nickel Plated Manifold Outlet |
MLTPL |
RAUPEX x R-20 |
ASTM F877 |
|||
| 3/8" (418315) | ||||||
| 1/2" (418317) | ||||||
| 5/8" (418318) | ||||||
| 3/4" (F418319) | ||||||
Nickel Plated Manifold Outlet¢ |
MLTPL |
RAUPEX x R-20 |
CSA B137.5 |
|||
| 3/8" (418315) | ||||||
| 1/2" (418317) | ||||||
| 5/8" (418318) | ||||||
| 3/4" (F418319) | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. |
||||||
Everloc+ x R-20[1] |
MLTPL |
Rehau |
ASTM F877 |
|||
| 3/8" (431459-001) | ||||||
| 1/2" (431461-001) | ||||||
| 5/8" (431462-001) | ||||||
| 3/4" (431463-001) | ||||||
[1] Nickel Plated Manifold Outlet |
||||||
Everloc+ x R-20¢ [1] |
MLTPL |
Rehau |
CSA B137.5 |
|||
| 3/8" (431459-001) | ||||||
| 1/2" (431461-001) | ||||||
| 5/8" (431462-001) | ||||||
| 3/4" (431463-001) | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. [1] Nickel Plated Manifold Outlet |
||||||
Facility : # 6 Canada
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard | |||
EVERLOC+ LF Manifold§ +++ [G] |
MLTPL |
REHAU |
ASTM F877 |
|||
| EVERLOC+ LF Mfld CE 1", (10) 1/2"Out (108466) | ||||||
| EVERLOC+ LF Mfld CE 1", (8) 1/2"Out (108465) | ||||||
| Mfld CE (3) 1/2" Out (105136) | ||||||
| EVERLOC+ LF Mfld CE 1", (4) 1/2" Out (104892) | ||||||
| EVERLOC+ LF Mfld CE 3/4", (6) 1/2"Out (104893) | ||||||
| EVERLOC+ LF Mfld CE 1", (6) 1/2"Out (104894) | ||||||
| EVERLOC+ LF Mfld FT 1"x3/4", (4) 1/2"Out (104895) | ||||||
| EVERLOC+ LF Mfld FT 1" x 1", (4) 1/2"Out (104896) | ||||||
| EVERLOC+ LF Mfld FT ¾" x ¾", (6) 1/2"Out (104897) | ||||||
| EVERLOC+ LF Mfld FT 1" x ¾", (6) 1/2"Out (104898) | ||||||
| EVERLOC+ LF Mfld H, (3)3/4", (4) 1/2"Out (104899) | ||||||
| EVERLOC+ LF Mfld CTL, 1"Header, (24)½"Out (104902) | ||||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
EVERLOC+ LF Manifold§ +++ [G] |
MLTPL |
REHAU |
CSA B137.5 |
|||
| EVERLOC+ LF Mfld CE 1", (10) 1/2"Out (108466) | ||||||
| EVERLOC+ LF Mfld CE 1", (8) 1/2"Out (108465) | ||||||
| Mfld CE (3) 1/2" Out (105136) | ||||||
| EVERLOC+ LF Mfld CE 1", (4) 1/2" Out (104892) | ||||||
| EVERLOC+ LF Mfld CE 3/4", (6) 1/2"Out (104893) | ||||||
| EVERLOC+ LF Mfld CE 1", (6) 1/2"Out (104894) | ||||||
| EVERLOC+ LF Mfld FT 1"x3/4", (4) 1/2"Out (104895) | ||||||
| EVERLOC+ LF Mfld FT 1" x 1", (4) 1/2"Out (104896) | ||||||
| EVERLOC+ LF Mfld FT ¾" x ¾", (6) 1/2"Out (104897) | ||||||
| EVERLOC+ LF Mfld FT 1" x ¾", (6) 1/2"Out (104898) | ||||||
| EVERLOC+ LF Mfld H, (3)3/4", (4) 1/2"Out (104899) | ||||||
| EVERLOC+ LF Mfld CTL, 1"Header, (24)½"Out (104902) | ||||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Facility : # 7 USA
Surface Burning Characteristics of Building Materials
| Product Type | Material Type | Trade Name | Product Standard | |||
Tubing* [1] |
PEX |
Municipex® |
ASTM E84 |
|||
| 3/4" - 2" | ||||||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing*** [1] |
PEX |
Municipex® |
ASTM E84 |
|||
| 3/4" - 2" | ||||||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
|
||||||
Tubing[2] [3] |
PEX |
Municipex® |
CAN/ULC S102.2 |
|||
| 3/4" - 2" | ||||||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
|
||||||
Tubing* [1] |
PEX |
Municipex® Reclaim |
ASTM E84 |
|||
| 3/4" - 2" | ||||||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing*** [1] |
PEX |
Municipex® Reclaim |
ASTM E84 |
|||
| 3/4" - 2" | ||||||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
|
||||||
Tubing[2] [3] |
PEX |
Municipex® Reclaim |
CAN/ULC S102.2 |
|||
| 3/4" - 2" | ||||||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
|
||||||
Tubing** [1] |
PEX |
Raupex® O2 Barrier |
ASTM E84 |
|||
| <= 1/2" | ||||||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing* [1] |
PEX |
Raupex® O2 Barrier |
ASTM E84 |
|||
| 5/8" - 2" | ||||||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing[3] |
PEX |
Raupex® O2 Barrier |
CAN/ULC S102.2 |
|||
| <= 1/2" | ||||||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
||||||
Tubing[2] [3] |
PEX |
Raupex® O2 Barrier |
CAN/ULC S102.2 |
|||
| 5/8" - 2" | ||||||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
|
||||||
Tubing** [1] |
PEX |
Raupex® |
ASTM E84 |
|||
| <= 3/4" | ||||||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing* [1] |
PEX |
Raupex® |
ASTM E84 |
|||
| 5/8" - 2" | ||||||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing*** [1] |
PEX |
Raupex® |
ASTM E84 |
|||
| 3/4" - 2" | ||||||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
|
||||||
Tubing[3] |
PEX |
Raupex® |
CAN/ULC S102.2 |
|||
| <= 1/2" | ||||||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
||||||
Tubing[2] [3] |
PEX |
Raupex® |
CAN/ULC S102.2 |
|||
| 5/8" - 2" | ||||||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
|
||||||
Tubing** [1] |
PEX |
Raupex® Blue UV Shield |
ASTM E84 |
|||
| <= 3/4" | ||||||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing* [1] |
PEX |
Raupex® Blue UV Shield |
ASTM E84 |
|||
| 5/8" - 2" | ||||||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing*** [1] |
PEX |
Raupex® Blue UV Shield |
ASTM E84 |
|||
| 3/4" - 2" | ||||||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
|
||||||
Tubing[1] **** |
PEX |
Raupex® Blue UV Shield |
ASTM E84 |
|||
| 1/2" - 2" | ||||||
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
**** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with
Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be
marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
|
||||||
Tubing[3] |
PEX |
Raupex® Blue UV Shield |
CAN/ULC S102.2 |
|||
| <= 1/2" | ||||||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
||||||
Tubing[2] [3] |
PEX |
Raupex® Blue UV Shield |
CAN/ULC S102.2 |
|||
| 5/8" - 2" | ||||||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
|
||||||
Tubing[3] [4] |
PEX |
Raupex® Blue UV Shield |
CAN/ULC S102.2 |
|||
| 1/2" - 2" | ||||||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+
Fittings as per Rehau installation instructions.
Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].
|
||||||
Tubing** [1] |
PEX |
Raupex® Red UV Shield |
ASTM E84 |
|||
| <= 3/4" | ||||||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing* [1] |
PEX |
Raupex® Red UV Shield |
ASTM E84 |
|||
| 5/8" - 2" | ||||||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing*** [1] |
PEX |
Raupex® Red UV Shield |
ASTM E84 |
|||
| 3/4" - 2" | ||||||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
|
||||||
Tubing[1] **** |
PEX |
Raupex® Red UV Shield |
ASTM E84 |
|||
| 1/2" - 2" | ||||||
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
**** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with
Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be
marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
|
||||||
Tubing[3] |
PEX |
Raupex® Red UV Shield |
CAN/ULC S102.2 |
|||
| <= 1/2" | ||||||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
||||||
Tubing[2] [3] |
PEX |
Raupex® Red UV Shield |
CAN/ULC S102.2 |
|||
| 5/8" - 2" | ||||||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
|
||||||
Tubing[3] [4] |
PEX |
Raupex® Red UV Shield |
CAN/ULC S102.2 |
|||
| 1/2" - 2" | ||||||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+
Fittings as per Rehau installation instructions.
Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].
|
||||||
Tubing** [1] |
PEX |
Raupex® White UV Shield |
ASTM E84 |
|||
| <= 3/4" | ||||||
** Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between tubing runs with Everloc+P, Everloc+ fittings. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50]. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing* [1] |
PEX |
Raupex® White UV Shield |
ASTM E84 |
|||
| 5/8" - 2" | ||||||
* Flame Spread Index and Smoke Developed Index based on when tubing is field insulated with minimum 1/2" Microlok HP Hi performance fiberglass insulation as per Rehau installation instructions. [1] Flame Spread Index <= 25; Smoke Developed Index <= 50. |
||||||
Tubing*** [1] |
PEX |
Raupex® White UV Shield |
ASTM E84 |
|||
| 3/4" - 2" | ||||||
*** Flame Spread Index and Smoke Developed Index based on ASTM E84 Steiner tunnel modified
using piping supported with a minimum length of 48-inch Rehau pipe supports spaced a
maximum distance of 10-inches between each Rehau Pipe Support Run. Tubing shall be
marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
|
||||||
Tubing[1] **** |
PEX |
Raupex® White UV Shield |
ASTM E84 |
|||
| 1/2" - 2" | ||||||
[1] Flame Spread Index <= 25; Smoke Developed Index <= 50.
**** Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" Micro-lok HP Hi performance fiberglass insulation with
Everloc+P/Everloc+ Fittings as per Rehau installation instructions. Tubing shall be
marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
|
||||||
Tubing[3] |
PEX |
Raupex® White UV Shield |
CAN/ULC S102.2 |
|||
| <= 1/2" | ||||||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50. |
||||||
Tubing[2] [3] |
PEX |
Raupex® White UV Shield |
CAN/ULC S102.2 |
|||
| 5/8" - 2" | ||||||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
|
||||||
Tubing[3] [4] |
PEX |
Raupex® White UV Shield |
CAN/ULC S102.2 |
|||
| 1/2" - 2" | ||||||
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[4] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with 1/2" Micro-lok HP Hi performance fiberglass insulation with Everloc+P/Everloc+
Fittings as per Rehau installation instructions.
Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].
|
||||||
Tubing[2] [3] |
PEX |
RAUGEO |
CAN/ULC S102.2 |
|||
| 3/4" - 2" | ||||||
[2] Flame Spread Index and Smoke Developed Index based on when tubing is field insulated
with minimum 1/2" JM Microlok or Armaflex insulation as per Rehau installation
instructions.
[3] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
|
||||||
Fire Sprinkler Pipe and Fitting Systems
| Product Type | Material Type | Trade Name | Product Standard | ||||
Pipe and Fitting System% ** [G] |
MLTPL |
FIREPEX™ Residential Fire Sprinkler Systems |
ANSI/CAN/UL 1821 |
||||
|
45 Deg, PEX to PEX Elbow |
|||||||
| 45 Deg Elbow 1 1/2 x 1 1/2 in. (499872) | 45 Deg Elbow 2 x 2 in. (499873) | ||||||
|
90 Degree Elbow |
|||||||
| 3/4" x 3/4" (F209E66) | 1" x 1" (F209E88) | 1 1/4" x 1 1/4" (F20E10) | |||||
|
Adapter, PEX to CP |
|||||||
| 1/2" x 3/4" | 3/4" x 3/4" | 3/4" x 1" | 1" x 3/4" | ||||
| 1" x 1" | 1 1/4" x 1 1/4" | 1 1/2" x 1 1/2" | 2" x 2" | ||||
|
Adapter, PEX to Copper |
|||||||
| 1/2" x 3/4" Male (499790) | 1/2" x 3/4" Female (499793) | 3/4" x 1/2" Male (499792) | 3/4" x 1/2" Female | ||||
| 5/8'' x 3/4'' Male (499861) | 5/8'' x 3/4'' Female (499862) | 3/4" x 3/4" Male (499796) | 3/4" x 3/4" Female (499797) | ||||
| 3/4" x 1" Male (499791) | 3/4" x 1" Female (499798) | 1" x 1" Male (499799) | 1" x 1" Female (499800) | ||||
| 1 1/4" x 1 1/4" Male (499801) | 1 1/4" x 1 1/4" Female (499802) | 1 1/2" x 1 1/2" Male (499803) | 1 1/2" x 1 1/2" Female (499804) | ||||
| 2" x 2" Male (499805) | 2" x 2" Female (499806) | ||||||
|
Adapter, PEX to FPT |
|||||||
| 1/2" x 3/4" (499819) | 3/4" x 3/4" (499822) | 3/4" x 1" (499820) | 1" x 3/4" | ||||
| 1" x 1" (499823) | 1 1/4" x 1 1/4" (499863) | 1 1/2" x 1 1/2" (499864) | 2" x 2" (499866) | ||||
|
Adapter, PEX to MPT |
|||||||
| 1/2" x 3/4" (499810) | 3/4" x 3/4" (499808) | 3/4" x 1" (499814) | 1" x 3/4" (499809) | ||||
| 1" x 1" (499815) | 1 1/4" x 1 1/4" (499816) | 1 1/2" x 1 1/2" (499817) | 2" x 2" (499818) | ||||
|
Branch + Run Reducing Tee |
|||||||
| Tee, 3/4 x 1/2 x 1/2 in. (499754) | Tee, 1 x 3/4 x 3/4 in. (499755) | Tee, 1 1/4 x 1 x 1/2 in. (499852) | Tee, 1 1/4 x 1 x 3/4 in. (499760) | ||||
| Tee, 1 1/4 x 1 x 1 in. (499756) | Tee, 1 1/2 x 1 x 3/4 in. (499761) | Tee, 1 1/2 x 1 x 1 in. (499757) | Tee, 1 1/2 x 1 x 1 1/4 in. (499853) | ||||
| Tee, 1 1/2 x 1 1/4 x 3/4 in. (499763) | Tee, 1 1/2 x 1 1/4 x 1 in. (499762) | Tee, 1 1/2 x 1 1/4 x 1 1/4 in. (499758) | Tee, 2 x 1 1/2 x 1/2 in. (499881) | ||||
| Tee, 2 x 1 1/2 x 3/4 in. (499877) | Tee, 2 x 1 1/2 x 1 in. (499878) | Tee, 2 x 1 1/2 x 1 1/4 in. (499879) | Tee, 2 x 1 1/2 x 1 1/2 in. (499880) | ||||
|
Branch Reducing Tee |
|||||||
| Tee, 3/4 x 3/4 x 1/2 in. (499739) | Tee, 1 x 1 x 1/2 in. (499741) | Tee, 1 x 1 x 3/4 in. (499740) | Tee, 1 1/4 x 1 1/4 x 1/2 in. (499744) | ||||
| Tee, 1 1/4 x 1 1/4 x 3/4 in. (499743) | Tee, 1 1/4 x 1 1/4 x 1 in. (499742) | Tee 1 1/2 x 1 1/2 x 1/2 in. (499876) | Tee, 1 1/2 x 1 1/2 x 3/4 in. (499753) | ||||
| Tee, 1 1/2 x 1 1/2 x 1 in. (499746) | Tee, 1 1/2 x 1 1/2 x 1 1/4 in. (499747) | Tee, 2 x 2 x 1/2 in. (499883) | Tee, 2 x 2 x 3/4 in. (499882) | ||||
| Tee, 2 x 2 x 1 in. (499752) | Tee, 2 x 2 x 1 1/4 in. (499748) | Tee, 2 x 2 x 1 1/2 in. (499749) | |||||
|
Bullhead Tee |
|||||||
| Tee, 1/2 x 1/2 x 3/4 in. (499767) | Tee, 3/4 x 3/4 x 1 in. (499768) | ||||||
|
Drop Ear Elbow, PEX to FPT |
|||||||
| 3/4" x 3/4" (499787) | |||||||
|
EVERLOC+ LF 45 DEG Elbow |
|||||||
| 1 1/2" x 1 1/2" (425021) | 2" x 2" (425022) | ||||||
|
EVERLOC+ LF Adapter |
|||||||
| 1/2" x 1/2" CF (317184) | 3/4" x 3/4" MPT (317172) | 3/4" x 3/4" FPT (317182) | 3/4" x 3/4" CM (317186) | ||||
| 3/4" x 3/4" CF (317187) (499797) | 3/4" x 1" MPT (317177) | 3/4" x 1" CF (317189) | 1" x 3/4" MPT (323708) | ||||
| 1" x 3/4" FPT (329227) | 1" x 1" MPT (317178) | 1" x 1" FPT (317183) | 1" x 1" CM (317190) | ||||
| 1" x 1" CF (317191) (499800) | 1 1/4" x 1 1/4" MPT (317179) | 1 1/4" x 1 1/4" CM (317192) | 1 1/4" x 1 1/4" CF (317193) | ||||
| 1 1/2" x 1 1/2" MPT (317180) | 1 1/2" x 1 1/2" CM (317194) | 1 1/2" x 2" CM or 1 1/2" CF (317195) | 2" x 2" MPT (317181) | ||||
| 2" x 2" CM (317196) | 2" x 2" CF (317197) | ||||||
|
EVERLOC+ LF Coupling |
|||||||
| 1-1/4" x 3/4" (425026) | 1-1/2" x 3/4" (425028) | 2" x 3/4" (425031) | 2" x 1" (317139) | ||||
| 2" x 1 1/4" (317140) | 2" x 1 1/2" (317141) | ||||||
|
EVERLOC+ LF Elbows |
|||||||
| 3/4" x 3/4" CM (317166) | 3/4" (317167) | 3/4" x 3/4" MPT (317169) | 3/4" x 3/4" FPT (422006) | ||||
| 3/4"x 3/4" MPT (425476) | 1" x 1" FPT (422007) | ||||||
|
EVERLOC+ LF Tees |
|||||||
| 1 1/4" x 1" x 3/4" (424989) | 1 1/4" x 1 1/4" x 1/2" (424991) | 1 1/4" x 1 1/4" x 3/4" (322832) | 1 1/2" x 1 1/4" x 1" (317153) | ||||
| 2" x 1 1/2" x 1 1/4" (317161) | 1 1/2" x 1 1/4" x 1 1/2" (317145) | 2" x 1 1/2" x 1 1/2" (317155) | 1 1/2" x 1 1/2" x 3/4" (322833) | ||||
| 2" x 1 1/2" x 2" (317147) | 1 1/2" x 1 1/2" x 1/2" (425024) | 1 1/2" x 1 1/4" x 3/4" (425025) | 1 1/2" x 1" x 3/4" (424992) | ||||
| 2" x 1 1/4" x 2" (317146) | 2" x 2" x 3/4" (322834) | 2" x 1 1/2" x 1" (317156) | 2" x 1 1/2" x 3/4" (424994) | ||||
| 2" x 2" x 1/2" (424995) | |||||||
|
EVERLOC+ Manifold Sweat Adapter |
|||||||
| 3/4" X 1" CF (326712) | 1" X 1" CM (326713) | ||||||
|
EVERLOC+ Polymer 45° Elbow |
|||||||
| 2” x 2” | 1 ½” x 1 ½” | ||||||
|
EVERLOC+ Polymer Coupling |
|||||||
| 1 ¼” x ¾” (435718) | 1 ½” x 1 ¼” (435704) | 2” x 1” | 2” x 1 ¼” | ||||
| 2” x 1 ½” (435706) | 1 ½” x ¾” (435705) | ||||||
|
EVERLOC+P Coupling |
|||||||
| 3/4" x 3/4" (104825) | 1" x 3/4" (104831) | 1" x 1" (104826) | 1 1/4" x 1" (104832) | ||||
| 1 1/4" x 1 1/4" (104827) | 1 1/2" x 1" (104833) | 1 1/2" x 1 1/2" (104828) | 2" x 2" (104829) | ||||
|
EVERLOC+P Elbow |
|||||||
| 3/4" x 3/4" (104860) | 1" x 1" (104861) | 1 1/4" x 1 1/4" (104862) | 1 1/2" x 1 1/2" (104863) | ||||
| 2" x 2" (104864) | |||||||
|
EVERLOC+P Plug |
|||||||
| 3/4" (104857) | 1" (104858) | 1 1/4" (317158) | 1 1/2" (317159) | ||||
| 2" (317160) | |||||||
|
EVERLOC+P Tee |
|||||||
| 3/4" x 1/2" x 3/4" (104841) | 3/4" x 3/4" x 3/4" (104836) | 3/4" x 3/4" x 1" (104855) | 1" x 3/4" x 3/4" (104852) | ||||
| 1" x 3/4" x 1" (104842) | 1" x 1" x 1" (104837) | 1 1/4" x 1" x 1" (104853) | 1 1/4" x 1 1/4" x 1 1/4" (104838) | ||||
| 1 1/4" x 1 1/4" x 1" (104847) | 1 1/2" x 1 1/2" x 1" (104848) | 1 1/2" x 1 1/2" x 1 1/2" (104839) | 2" x 2" x 1" (104849) | ||||
| 2" x 2" x 2" (104840) | |||||||
|
EVERLOC+Sleeves |
|||||||
| 3/4" (104818) | 1" (104819) | 1 1/4" (104820) | 1 1/2" (104821) | ||||
| 2" (104822) | |||||||
|
Elbow, PEX to CP |
|||||||
| 3/4" x 3/4" | |||||||
|
Elbow, PEX to Copper |
|||||||
| 3/4" x 3/4" Male (499784) | 3/4" x 3/4" Female (499785) | 5/8" x 3/4" Male (499857) | 5/8" x 3/4" Female (499858) | ||||
|
Everloc+ Polymer Tee |
|||||||
| 2” x 2” x ¾” (435721) | 2” x 2” x ½” | 1 ¼” x 1 ¼” x ¾” (435700) | 1 ¼” x 1” x 1 ¼” (435712) | ||||
| 1 ¼” x 1” x ¾” | 1 ¼” x ¾” x 1 ¼” (435717) | 1 ¼” x ¾” x ¾” (435715) | 1 ½” x 1 ¼” x 1 ¼” (435720) | ||||
| 1 ½” x 1 ¼” x 1 ½” | 1 ½” x 1 ¼” x 1” | 1 ½” x 1 ¼” x ¾” (435711) | 1 ½” x 1 ½” x 1 ¼” (435713) | ||||
| 1 ½” x 1 ½” x ½” (435707) | 1 ½” x 1 ½” x ¾” (435702) | 1 ½” x 1” 1 ½” (435709) | 1 ½” x 1” x 1” (435719) | ||||
| 1 ½” x 1” x ¾” | 1 ½” x ¾” x 1 ½” (435716) | 1" x ½” x 1" (435809) | 1" x ¾” x ½” (435701) | ||||
| 2” x 1 ¼” x 2” | 2” x 1 ½” x 1 ¼” | 2” x 1 ½” x 1 ½” | 2” x 1 ½” x 1” | ||||
| 2” x 1 ½” x 2” | 2” x 1 ½” x ¾” | 2” x 2” x 1 ¼” (435714) | 2” x 2” x 1 ½” (435710) | ||||
| 1 ¼” x 1 ¼” x ½” (435703) | |||||||
|
Everloc+ Stub Ell |
|||||||
| 3/4" 8" (418668) (499364) | 3/4" 8" with mounting plate (329229) (499307) | 1" 8" (499365) | |||||
|
LF Brass Adapter |
|||||||
| 3/4" x 3/4" C Female (499797) | 1" x 1" C Female (499800) | ||||||
|
Male Threaded Adapter |
|||||||
| 3/4" x 3/4" (F96E66) | 1" x 1" (F96E88) | 1 1/4" x 1 1/4" (F96E1010) | |||||
|
PEX to PEX Elbow |
|||||||
| Elbow, 3/4 x 1/2 in. (490318) | Elbow, 3/4 x 3/4 in. (499777) | Elbow, 1 x 1 in. (499778) | Elbow, 1 1/4 x 1 1/4 in. (499779) | ||||
| Elbow, 1 1/2 x 1 1/2 in. (499780) | Elbow, 2 x 2 in. (499781) | ||||||
|
Plug |
|||||||
| 3/4" F2080 (F103E6) | 1" F2080 (F103E8) | 1 1/4" F2080 (F103E10) | Plug, 3/4 in. (499771) | ||||
| Plug, 1 in. (499772) | Plug, 1 1/4 in. (499773) | Plug, 1 1/2 in. (499774) | Plug, 2 in. (499775) | ||||
|
Reducing Coupling |
|||||||
| 3/4" x 1/2" (F95E64) | 1 X 3/4" (F95E86) | 1 1/4" X 1" (F95E108) | Coupling, 3/4 x 1/2 in. (499717) | ||||
| Coupling, 1 x 1/2 in. (490319) | Coupling, 1 x 3/4 in. (499718) | Coupling, 1 1/4 x 3/4 in. (499721) | Coupling, 1 1/4 x 1 in. (499719) | ||||
| Coupling, 1 1/2 x 3/4 in. (499874) | Coupling 1 1/2 x 1 in. (499875) | Coupling, 1 1/2 x 1 1/4 in. (499723) | Coupling, 2 x 1 1/2 in. (499724) | ||||
|
Reinforcing Rings |
|||||||
| 3/4" (499704) | 1" (499705) | 1 1/4" (499706) | 1 1/2" (499707) | ||||
| 2" (499708) | |||||||
|
Run Reducing Tee |
|||||||
| Tee, 3/4 x 1/2 x 3/4 in. (499734) | Tee, 1 x 3/4 x 1 in. (499735) | Tee 1 1/4 x 3/4 x 1 1/4 in. (499846) | Tee 1 1/4 x 1 x 1 1/4 in. (499736) | ||||
| Tee, 1 1/2 x 3/4 x 1 1/2 in. (499847) | Tee, 1 1/2 x 1 x 1 1/2 in. (499737) | Tee, 1 1/2 x 1 1/4 x 1 1/2 in. (499848) | Tee, 2 x 1 x 2 in. (499849) | ||||
| Tee, 2 x 1 1/4 x 2 in. (499850) | Tee, 2 x 1 1/2 x 2 in. (499738) | ||||||
|
Sprinkler Elbows |
|||||||
| 3/4" x 1/2" FPT (422004) | 1" x 1/2" FPT (422005) | ||||||
|
Sprinkler Flow Through |
|||||||
| 1” F1960 x 1” FPT | |||||||
|
Sprinkler Tees |
|||||||
| 3/4" x 3/4" x 1/2" FPT (421744) | 1" x 1" x 1/2" FPT (421878) | ||||||
|
Straight Coupling |
|||||||
| Coupling, 3/4 x 3/4 in. (499710) | Coupling, 1 x 1 in. (499711) | Coupling, 1 1/4 x 1 1/4 in. (499712) | Coupling, 1 1/2 x 1 1/2 in. (499714) | ||||
| Coupling, 2 x 2 in. (499715) | |||||||
|
Straight Tee |
|||||||
| Tee, 3/4 x 3/4 x 3/4 in. (499729) | Tee, 1 x 1 x 1 in. (499730) | Tee, 1 1/4 x 1 1/4 x 1 1/4 in. (499731) | Tee, 1 1/2 x 1 1/2 x 1 1/2 in. (499732) | ||||
| Tee, 2 x 2 x 2 in. (499733) | |||||||
|
Stub Ell 8" |
|||||||
| 3/4" (499364) | 1" (499365) | ||||||
|
Stub Ell 8" with mounting plate |
|||||||
| 3/4" (499307) | |||||||
|
Tees |
|||||||
| 3/4" x 1/2" x 1/2" [F208E644] | 3/4" x 1/2" x 3/4" [F208E646] | 3/4" x 3/4" x 1/2" [F208E664] | 3/4" x 3/4" x 3/4" [F208E666] | ||||
| 1" x 1" x 3/4" [F208E886] | 1" x 1" x 1" [F208E888] | 1 1/4" x 3/4" x 1" [F208E1068] | 1 1/4" x 1 1/4" x 3/4" [F208E10106] | ||||
| 1 1/4" x 1 1/4" x 1" [F208E10108] | |||||||
|
Tubing |
|||||||
| 3/4" – 2" Raupex | 3/4" - 2" Raupex White UV- Shield | ||||||
% PEX pipe and fittings are intended for use in multi-purpose piping systems of
residential occupancies as defined in ANSI/NFPA 13D, “Installation of Sprinkler Systems
in One- and Two- Family Dwellings and Manufactured Homes" and the International
Residential Code, Section P2904, and are designed to withstand a working pressure of not
less than 130 psi at 120°F. PEX pipe and fittings are intended to be installed in
accordance with the requirements specified in the manufacturer’s installation
instructions and ANSI/NFPA 13D. Protection is intended to be provided for PEX pipe and
fittings in multi-purpose piping systems unless otherwise stated in this listing and per
the installation and design manual dated September 11, 2008. The minimum protection
should consist of either (1) one layer of 3/8-in. gypsum wallboard, (2) a suspended
membrane ceiling with lay-in panels or tiles having a weight of not less than 0.35 lbs
per sq ft when installed with metallic support grids, OR (3) ½ in plywood. PEX pipe and
fittings are intended for use in areas where the maximum ambient temperature does not
exceed 120°F. These pipe and fittings are not intended to be installed in outdoor
applications. The PEX pipe and fittings are intended for use in wet-pipe systems only
and have not been evaluated for use in dry-pipe systems. Raupex pipe and fittings may
also be installed without protection (exposed) in accordance with the limitations
specified in this installation and design manual dated September 11, 2008.
** Pipe and fittings Certified as a system using installation and design manual titled
"FIREPEX Residential Fire Sprinkler Systems".
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard | ||||
Pipe* ^ § $$ +++ [G] |
PEX 3306 |
MUNICIPEX |
ASTM F876/F877 |
||||
| 1/2" - 2" SDR 9 | |||||||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe* ^ § $$ +++ [G] |
PEX 3306 |
MUNICIPEX |
AWWA C904 |
||||
| 1/2" - 2" SDR 9 | |||||||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe* ^ § $$ +++ [G] |
PEX 5306 |
MUNICIPEX |
ASTM F876/F877 |
||||
| 1/2" - 2" SDR 9 | |||||||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe% * ^ ¢ § $$ +++ [G] |
PEX 5306 |
MUNICIPEX |
CSA B137.5 |
||||
| 1/2" SDR 9 | |||||||
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F877,
F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe% * ^ ¢ § $$ +++ [G] |
PEX |
MUNICIPEX |
CSA B137.5 |
||||
| 3/4" - 2" | |||||||
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F877,
F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe* ^ +++ [G] |
PEX 3306 |
MUNICIPEX Protect |
ASTM F876/F877 |
||||
| 3/4" - 2" SDR 9 | |||||||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe* ^ +++ [G] |
PEX 3306 |
MUNICIPEX Protect |
AWWA C904 |
||||
| 3/4" - 2" SDR 9 | |||||||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe% * ^ ¢ § +++ [G] |
PEX |
MUNICIPEX Protect |
CSA B137.5 |
||||
| 3/4" - 2" SDR 9 | |||||||
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F877,
F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe* ^ § $$ +++ [G] |
PEX 3306 |
RAUPEX® Blue UV-Shield |
ASTM F876/F877 |
||||
| 3/8" - 2" SDR 9 | |||||||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe% * ^ ¢ § $$ +++ [G] |
PEX |
RAUPEX® Blue UV-Shield |
CSA B137.5 |
||||
| 1/2" - 2" SDR 9 | |||||||
| 3/8" - 2" | |||||||
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F877,
F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe* ^ § $$ +++ [G] |
PEX 5306 |
RAUPEX® Blue UV-Shield |
ASTM F876/F877 |
||||
| 1/2" - 2" SDR 9 | |||||||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe% * ^ ¢ § $$ +++ [G] |
PEX 5306 |
RAUPEX® Blue UV-Shield |
CSA B137.5 |
||||
| 1/2" SDR 9 | |||||||
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F877,
F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe* ^ § $$ +++ [G] |
PEX 3306 |
RAUPEX® Red UV-Shield |
ASTM F876/F877 |
||||
| 3/8" - 2" SDR 9 | |||||||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe% * ^ ¢ § $$ +++ [G] |
PEX |
RAUPEX® Red UV-Shield |
CSA B137.5 |
||||
| 1/2” - 2" SDR 9 | |||||||
| 3/8" - 2" | |||||||
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F877,
F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe* ^ § $$ +++ [G] |
PEX 5306 |
RAUPEX® Red UV-Shield |
ASTM F876/F877 |
||||
| 1/2” - 2" SDR 9 | |||||||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe% * ^ ¢ § $$ +++ [G] |
PEX 5306 |
RAUPEX® Red UV-Shield |
CSA B137.5 |
||||
| 1/2” SDR 9 | |||||||
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F877,
F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe* ^ § $$ +++ [G] |
PEX 3306 |
RAUPEX® White UV-Shield |
ASTM F876/F877 |
||||
| 3/8" - 2" SDR 9 | |||||||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe% * ^ ¢ § $$ +++ [G] |
PEX |
RAUPEX® White UV-Shield |
CSA B137.5 |
||||
| 1/2” - 2" SDR 9 | |||||||
| 3/8" - 2" | |||||||
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F877,
F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe* ^ § $$ +++ [G] |
PEX 5306 |
RAUPEX® White UV-Shield |
ASTM F876/F877 |
||||
| 1/2” - 2" SDR 9 | |||||||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Pipe% * ^ ¢ § $$ +++ [G] |
PEX 5306 |
RAUPEX® White UV-Shield |
CSA B137.5 |
||||
| 1/2” SDR 9 | |||||||
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F877,
F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
$$ Complies with US EPA Maximum Contaminant Levels (MCLs) for PFAS according to
NSF/ANSI/CAN 61.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
|||||||
Fittings¢ § |
PEX |
Rehau |
ASTM F877 |
||||
|
EVERLOC+Sleeves |
|||||||
| 3/8" (104815) | 1/2" (104816) | 5/8" (104817) | 3/4" (104818) | ||||
| 1" (104819) | 1 1/4" (104820) | 1 1/2" (104821) | 2" (104822) | ||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
Fittings¢ § |
PEX |
Rehau |
CSA B137.5 |
||||
|
EVERLOC+Sleeves |
|||||||
| 3/8" (104815) | 1/2" (104816) | 5/8" (104817) | 3/4" (104818) | ||||
| 1" (104819) | 1 1/4" (104820) | 1 1/2" (104821) | 2" (104822) | ||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
|||||||
& Tubing certified against CSA B137.5 shall include the standard designation(s) of the fitting system(s) for which the tubing is recommended by the manufacturer, and shall be marked, as applicable, with the following fitting system designation(s): AWWA C800. @ Product is exempted from bearing NSF-pw marking.
Reclaimed Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard | |||
PEX Pipe§ |
PEX 3306 |
MUNICIPEX Reclaim |
ASTM F876/F877 |
|||
| 1/2" - 2" | ||||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
PEX Pipe§ |
PEX 3306 |
MUNICIPEX Reclaim |
AWWA C904 |
|||
| 1/2" - 2" | ||||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
PEX Pipe% ¢ |
PEX |
MUNICIPEX Reclaim |
CSA B137.5 |
|||
| 1/2" - 2" | ||||||
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the fitting system(s) for which the tubing is recommended by the manufacturer, and shall be marked, as applicable, with the following fitting system designation(s): AWWA C800. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. |
||||||
Sewer Main - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard | |||
Pipe |
PEX 3306 |
MUNICIPEX Force Main |
ASTM F876/F877 |
|||
| 1" - 2" SDR 9 | ||||||
Pipe% ¢ |
PEX 3306 |
MUNICIPEX Force Main |
CSA B137.5 |
|||
| 1" - 2" SDR 9 | ||||||
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the fitting system(s) for which the tubing is recommended by the manufacturer, and shall be marked, as applicable, with the following fitting system designation(s): AWWA C800. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. |
||||||
Pipe |
PEX 3306 |
MUNICIPEX Force Main |
AWWA C904 |
|||
| 1" - 2" SDR 9 | ||||||
Geothermal Applications
| Product Type | Material Type | Trade Name | Product Standard | |||
Pipe¢ |
PEX |
REHAU® Raugeo |
CSA C448 |
|||
|
U-Bend |
||||||
| 1" | 2" | |||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. |
||||||
Pipe^ ¢ |
PEX |
REHAU® Raugeo |
CSA C448 |
|||
| 3/4" - 2" | ||||||
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with ASTM F2023. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. |
||||||
Pipe% ^ ¢ |
PEX |
REHAU® Raugeo |
CSA B137.5 |
|||
| 3/4" - 2" | ||||||
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the fitting system(s) for which the tubing is recommended by the manufacturer, and shall be marked, as applicable, with the following fitting system designation(s): ASTM F877, F1807, F1960, F2080 and F2159. ^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with ASTM F2023. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. |
||||||
Radiant Floor Heating
| Product Type | Material Type | Trade Name | Product Standard | |||
Pipe$ * ^ § |
PEX 3006 |
RAUPEX® |
ASTM F876/F877 |
|||
| 3/8" - 2" SDR 9 | ||||||
$ Non-barrier pipe. * Accepted by NSF for use in residential and commercial construction, including manufactured housing. ^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with ASTM F2023. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Pipe$ % * § |
PEX |
RAUPEX® |
CSA B137.5 |
|||
| 3/8" - 2" SDR 9 | ||||||
$ Non-barrier pipe. % Tubing certified against CSA B137.5 shall include the standard designation(s) of the fitting system(s) for which the tubing is recommended by the manufacturer, and shall be marked, as applicable, with the following fitting system designation(s): ASTM F877, F1807, F1960, F2080 and F2159. * Accepted by NSF for use in residential and commercial construction, including manufactured housing. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Pipe* ¥ |
PEX 0306 |
Raupex Black UV Shield |
ASTM F876/F877 |
|||
| 3/8" - 2" | ||||||
* Accepted by NSF for use in residential and commercial construction, including manufactured housing. ¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Mechanical Code™. |
||||||
Pipe* ¥ |
PEX 0006 |
Raupex Black UV Shield |
ASTM F876/F877 |
|||
| 3/8" - 2" | ||||||
* Accepted by NSF for use in residential and commercial construction, including manufactured housing. ¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Mechanical Code™. |
||||||
Pipe% * ¢ ¥ |
PEX |
Raupex Black UV Shield |
CSA B137.5 |
|||
| 3/8" - 2" | ||||||
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the fitting system(s) for which the tubing is recommended by the manufacturer, and shall be marked, as applicable, with the following fitting system designation(s): ASTM F877, F1807, F1960, F2080 and F2159. * Accepted by NSF for use in residential and commercial construction, including manufactured housing. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. ¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Mechanical Code™. |
||||||
Pipe |
PEX 3206 |
RAUPEX O2 Barrier |
SE 1091 |
|||
| 10.1 mm x 1.1 mm | ||||||
Facility : # 11 Switzerland
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard | |||
Pipe# * ^ § +++ [G] |
PEX 3306 |
Municipex PI |
ASTM F876/F877 |
|||
| 1" - 2" SDR 9 | ||||||
# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Pipe# * ^ § +++ [G] |
PEX 3306 |
Municipex PI |
AWWA C904 |
|||
| 1" - 2" SDR 9 | ||||||
# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Pipe# & * ^ ¢ § +++ [G] |
PEX |
Municipex PI |
CSA B137.5 |
|||
| 1" - 2" SDR 9 | ||||||
# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
& Tubing certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): AWWA C800.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Pipe# % * ^ ¢ § +++ [G] |
PEX |
Insulpex Blue UV Shield |
CSA B137.5 |
|||
| 1" - 2" SDR 9 | ||||||
# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F877,
F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Pipe# * ^ § +++ [G] |
PEX 3306 |
Insulpex Blue UV Shield |
ASTM F876/F877 |
|||
| 1" - 2" SDR 9 | ||||||
# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Pipe# * ^ § +++ [G] |
PEX 3306 |
Insulpex Red UV Shield |
ASTM F876/F877 |
|||
| 1" - 2" SDR 9 | ||||||
# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Pipe# % * ^ ¢ § +++ [G] |
PEX |
Insulpex Red UV Shield |
CSA B137.5 |
|||
| 1" - 2" SDR 9 | ||||||
# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F877,
F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Pipe# * ^ § +++ [G] |
PEX 3306 |
Insulpex White UV Shield |
ASTM F876/F877 |
|||
| 1" - 2" SDR 9 | ||||||
# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Pipe# % * ^ ¢ § +++ [G] |
PEX |
Insulpex White UV Shield |
CSA B137.5 |
|||
| 1" - 2" SDR 9 | ||||||
# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F877,
F1807, F1960, F2080 and F2159.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Facility : # 12 Canada
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard | |||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
EVERLOC+ Polymer 45° Elbow |
||||||
| 1 ½” x 1 ½” | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
EVERLOC+ Polymer 45° Elbow |
||||||
| 1 ½” x 1 ½” | ||||||
|
Everloc+ Polymer Tee |
||||||
| 1" x 1/2" x 1" (435809) | ||||||
|
EVERLOC+ Polymer Coupling |
||||||
| 1 ¼” x ¾” (435718) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
EVERLOC+ Polymer Coupling |
||||||
| 1 ¼” x ¾” (435718) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
EVERLOC+ Polymer 45° Elbow |
||||||
| 2” x 2” | ||||||
|
EVERLOC+ Polymer Coupling |
||||||
| 1 ½” x ¾” (435705) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
EVERLOC+ Polymer 45° Elbow |
||||||
| 2” x 2” | ||||||
|
EVERLOC+ Polymer Coupling |
||||||
| 1 ½” x ¾” (435705) | ||||||
|
Everloc+ Polymer Tee |
||||||
| 1" x 3/4" x 1/2" (435701) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1" x 3/4" x 1/2" (435701) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 1/4" x 3/4" x 3/4" (435715) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
EVERLOC+ Polymer Coupling |
||||||
| 1 ½” x 1 ¼” (435704) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
EVERLOC+ Polymer Coupling |
||||||
| 1 ½” x 1 ¼” (453704) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 1/4" x 3/4" x 3/4" (435715) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 1/4" x 3/4" x 1 1/4" (435717) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 1/4" x 3/4" x 1 1/4" (435717) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
EVERLOC+ Polymer Coupling |
||||||
| 2” x 1” | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
EVERLOC+ Polymer Coupling |
||||||
| 2” x 1” | 2” x 1 ¼” | |||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
EVERLOC+ Polymer Coupling |
||||||
| 2” x 1 ¼” | ||||||
|
Everloc+ Polymer Tee |
||||||
| 1 ¼” x 1” x 1 ¼” (435712) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ¼” x 1” x ¾” | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
EVERLOC+ Polymer Coupling |
||||||
| 2” x 1 ½” (435706) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
EVERLOC+ Polymer Coupling |
||||||
| 2” x 1 ½” (435706) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ¼” x 1” x ¾” | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ¼” x 1” x 1 ¼” (435712) | 1 ¼” x 1 ¼” x ½” (435703) | |||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ¼” x 1 ¼” x ½" (435703) | 1 ¼” x 1 ¼” x ¾” (435700) | |||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ¼” x 1 ¼” x ¾” (435700) | 1 1/2" x 3/4" x 1 1/2" (435716) | |||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 1/2" x 3/4" x 1 1/2" (435716) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ½” x 1” x ¾” | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ½” x 1” x ¾” | 1 ½” x 1” x 1" (435719) | |||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ½” x 1” x 1" (435719) | 1 ½” x 1” 1 ½” (435709) | |||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ½” x 1” 1 ½” (435709) | 1 ½” x 1 ¼” x ¾” (435711) | |||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ½” x 1 ¼” x ¾” (435711) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ½” x 1 ¼” x 1” | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ½” x 1 ¼” x 1” | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ½” x 1 ¼” x 1 ¼” (435720) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ½” x 1 ¼” x 1 ¼” (435720) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ½” x 1 ¼” x 1 ½” | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ½” x 1 ¼” x 1 ½” | 1 ½” x 1 ½” x ¾” (435702) | |||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ½” x 1 ½” x ½” (435707) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ½” x 1 ½” x ½” (435707) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ½” x 1 ½” x ¾” (435702) | 1 ½” x 1 ½” x 1 ¼” (435713) | |||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1 ½” x 1 ½” x 1 ¼” (435713) | 2” x 1 ½” x ¾” | |||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 2” x 1 ½” x ¾” | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 2” x 1 ½” x 1” | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 2” x 1 ½” x 1” | 2” x 1 ½” x 1 ¼” | |||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 2” x 1 ½” x 1 ¼” | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 2” x 1 ½” x 1 ½” | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 2” x 1 ½” x 1 ½” | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 2” x 1 ¼” x 2” | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 2” x 1 ¼” x 2” | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 2” x 1 ½” x 2” | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 2” x 1 ½” x 2” | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 2” x 2” x ½” | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 2” x 2” x ½” | 2” x 2” x ¾” (435721) | |||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 2” x 2” x ¾” (435721) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 2” x 2” x 1 ¼” (435714) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 2” x 2” x 1 ¼” (435714) | 2” x 2” x 1 ½” (435710) | |||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! ¢ § +++ [G] |
PPSU |
REHAU |
CSA B137.5 |
|||
|
Everloc+ Polymer Tee |
||||||
| 2” x 2” x 1 ½” (435710) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Fittings! § +++ [G] |
PPSU |
REHAU |
ASTM F877 |
|||
|
Everloc+ Polymer Tee |
||||||
| 1" x 1/2" x 1" (435809) | ||||||
! Product is Certified whether or not it bears the U.P. Code Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Facility : EU
Surface Burning Characteristics of Building Materials
| Product Type | Material Type | Trade Name | Product Standard | |||
Tubing[1] [2] |
PEX |
NEOPEX O2 Barrier |
ASTM E84 |
|||
| 1/2", 5/8", 3/4" | ||||||
[1] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[2] 1/2", 5/8" 3/4" Flame Spread Index and Smoke Developed Index based on when tubing is
field insulated with 1/2" Micro-lok HP Hi performance fiberglass insulation as per Rehau
installation instructions.
1/2" Only: Flame Spread Index and Smoke Developed Index based on minimum spacing of 18
inches between tubing runs with Everloc+P, Everloc+ fittings.
Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].
|
||||||
Tubing[1] [3] |
PEX |
NEOPEX O2 Barrier |
CAN/ULC S102.2 |
|||
| 1/2", 5/8", 3/4" | ||||||
[1] Flame Spread Value (FSV) <= 25; Smoke Developed Value (SDV) <= 50.
[3] 1/2" - Non-insulated
5/8" & 3/4": Flame Spread Index and Smoke Developed Index based on when tubing is field
instructions. insulated with minimum 1/2" JM Microlok or Armaflex insulation as per
Rehau installation.
Tubing shall be marked [cNSF®-fs CAN/ULC S102.2 FS<=25/SD<=50].
|
||||||
Radiant Floor Heating
| Product Type | Material Type | Trade Name | Product Standard | |||
Pipe§ |
PEX 0306 |
NEOPEX O2 Barrier |
ASTM F876/F877 |
|||
| 3/8" - 2" SDR 9 | ||||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Pipe% ¢ |
PEX 0306 |
NEOPEX O2 Barrier |
CSA B137.5 |
|||
| 3/8" - 2" SDR 9 | ||||||
% Tubing certified against CSA B137.5 shall include the standard designation(s) of the fitting system(s) for which the tubing is recommended by the manufacturer, and shall be marked, as applicable, with the following fitting system designation(s): ASTM F877, ASTM F1960 and ASTM F2080. ¢ Product is authorized to bear the cNSF and/or the cNSFus Mark. |
||||||
Number of matching Manufacturers is 1
Number of matching Products is 1240