NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, January 15, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/Plumbing/Listings.asp?Company=C0069327&Standard=014&
NSF/ANSI 14
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
| Trelleborg Pipe Seals Tijuana S.A de C.V | |
| Colina No. 11850, Parque | |
| Industrial el Florido, Sección Colinas | |
| Tijuana, BC 22237 | |
| Mexico | |
| 52 664 625 4885 |
Facility : Tijuana, Baja California, Mexico
Fire Main - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard | |||
Gasket/Sealing Materials+ ~ |
SBR |
T-565 RIEBER C-900 SBR |
FM 1612 |
|||
| 4" - 48" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
SBR |
T-559 RIEBER PRESSURE METRIC SBR |
FM 1612 |
|||
| 450 mm - 1200 mm | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
SBR |
T-560 RIEBER IPS SBR |
FM 1612 |
|||
| 1-1/2" - 24" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
SBR |
MP 148 T-559 RIEBER PRESSURE METRIC SBR |
FM 1612 |
|||
| 450" - 1200" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
SBR |
MP 148 T-560 RIEBER IPS SBR |
FM 1612 |
|||
| 1-1/2" - 24" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
SBR |
MP 148 T-565 RIEBER C-900 SBR |
FM 1612 |
|||
| 4" - 48" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
SBR |
CERTA-LOK O-RING SBR |
FM 1612 |
|||
| 5" - 48" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
NBR |
T-560 RIEBER IPS NITRILE |
FM 1612 |
|||
| 1 1/2 - 24 in | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
NBR |
T-565 RIEBER C-900 NITRILE |
FM 1612 |
|||
| 4" - 48" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
NBR |
NR 648 T-560 RIEBER IPS NITRILE |
FM 1612 |
|||
| 1-1/2" - 24" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
NBR |
NR 648 T-565 RIEBER C-900 NITRILE |
FM 1612 |
|||
| 4" - 48" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
NBR |
CERTA-LOK O-RING NITRILE |
FM 1612 |
|||
| 2" - 10" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
NBR |
FLUID-TITE NITRILE CIOD |
FM 1612 |
|||
| 6" - 24" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
EPDM |
T-560 RIEBER IPS EPDM |
FM 1612 |
|||
| 1-1/2" - 24" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
EPDM |
T-565 RIEBER C-900 EPDM |
FM 1612 |
|||
| 4" - 48" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
EPDM |
T-584 ANGER LOCK EPDM |
FM 1612 |
|||
| 4" - 48" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
EPDM |
T-552 ANGER LOCK IPS EPDM |
FM 1612 |
|||
| 2"-14" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
EPDM |
T-603 POWER LOCK IPS EPDM |
FM 1612 |
|||
| 1-1/2" - 12" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
EPDM |
E 148 T-560 RIEBER IPS EPDM |
FM 1612 |
|||
| 1-1/2" - 24" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
EPDM |
E 148 T-565 RIEBER C-900 EPDM |
FM 1612 |
|||
| 4" - 48" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
EPDM |
E 148 T-552 ANGER LOCK IPS EPDM |
FM 1612 |
|||
| 2"-14" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
EPDM |
E 148 T-584 ANGER LOCK EPDM |
FM 1612 |
|||
| 4" - 48" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
EPDM |
E 148 T-603 POWER LOCK IPS EPDM |
FM 1612 |
|||
| 1-1/2" - 12" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
EPDM |
CERTA-LOK O-RING EPDM |
FM 1612 |
|||
| 2"-10" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Gasket/Sealing Materials+ ~ |
EPDM |
FLUID-TITE EPDM CIOD |
FM 1612 |
|||
| 6"-24" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F. ~ Use of this material in NSF Certified pipe requires NSF's prior authorization. |
||||||
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard | |||
Gasket/Sealing Materials+ [1] [G] |
SBR |
MP 148 T-559 RIEBER PRESSURE METRIC SBR |
ASTM F477 |
|||
| 450 mm - 1200 mm | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Certified for a maximum surface area to volume ratio of 2.0 sq. in./L.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [1] [G] |
SBR |
MP 148 T-560 RIEBER IPS SBR |
ASTM F477 |
|||
| 1 1/2" - 24" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Certified for a maximum surface area to volume ratio of 2.0 sq. in./L.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [1] [G] |
SBR |
MP 148 T-565 RIEBER C-900 SBR |
ASTM F477 |
|||
| 4" - 48" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Certified for a maximum surface area to volume ratio of 2.0 sq. in./L.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [1] [G] |
SBR |
T-559 RIEBER PRESSURE METRIC SBR |
ASTM F477 |
|||
| 450 mm - 1200 mm | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Certified for a maximum surface area to volume ratio of 2.0 sq. in./L.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [1] [G] |
SBR |
T-560 RIEBER IPS SBR |
ASTM F477 |
|||
| 1 1/2" - 24" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Certified for a maximum surface area to volume ratio of 2.0 sq. in./L.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [1] [G] |
SBR |
T-565 RIEBER C-900 SBR |
ASTM F477 |
|||
| 4" - 48" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Certified for a maximum surface area to volume ratio of 2.0 sq. in./L.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [G] |
NBR |
NR 648 T-560 RIEBER IPS NITRILE |
ASTM F477 |
|||
| 1 1/2" - 24" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [G] |
NBR |
NR 648 T-565 RIEBER C-900 NITRILE |
ASTM F477 |
|||
| 4" - 48" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [G] |
NBR |
T-560 RIEBER IPS NITRILE |
ASTM F477 |
|||
| 1 1/2" - 24" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [G] |
NBR |
T-565 RIEBER C-900 NITRILE |
ASTM F477 |
|||
| 4" - 12" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [G] |
EPDM |
E 148 T-560 RIEBER IPS EPDM |
ASTM F477 |
|||
| 1 1/2" - 24" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [G] |
EPDM |
E 148 T-565 RIEBER C-900 EPDM |
ASTM F477 |
|||
| 4" - 48" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [G] |
EPDM |
E 148 T-584 ANGER LOCK EPDM |
ASTM F477 |
|||
| 4" - 48" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [G] |
EPDM |
E 148 T-552 ANGER LOCK IPS EPDM |
ASTM F477 |
|||
| 2" - 14" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [G] |
EPDM |
E 148 T-603 POWER LOCK IPS EPDM |
ASTM F477 |
|||
| 1 1/2" - 12" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [G] |
EPDM |
T-560 RIEBER IPS EPDM |
ASTM F477 |
|||
| 1 1/2" - 24" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [G] |
EPDM |
T-565 RIEBER C900 EPDM |
ASTM F477 |
|||
| 4" - 48" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [G] |
EPDM |
T-584 ANGER LOCK EPDM |
ASTM F477 |
|||
| 4" - 48" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [G] |
EPDM |
T-552 ANGER LOCK IPS EPDM |
ASTM F477 |
|||
| 2" - 14" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [G] |
EPDM |
T-603 POWER LOCK IPS EPDM |
ASTM F477 |
|||
| 1 1/2" - 12" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [G] |
NBR |
FLUID-TITE NITRILE CIOD |
ASTM F477 |
|||
| 6"- 24" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [G] |
EPDM |
FLUID-TITE EPDM CIOD |
ASTM F477 |
|||
| 6"- 24" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [G] |
NBR |
CERTA-LOK O-RING NITRILE |
ASTM F477 |
|||
| 2" - 10" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [G] |
EPDM |
CERTA-LOK O-RING EPDM |
ASTM F477 |
|||
| 2" - 10" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Gasket/Sealing Materials+ [1] [G] |
SBR |
CERTA-LOK O-RING SBR |
ASTM F477 |
|||
| 5"- 48" | ||||||
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Certified for a maximum surface area to volume ratio of 2.0 sq. in./L.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Number of matching Manufacturers is 1
Number of matching Products is 50
Processing time was 0 seconds