NSF Product and Service Listings

These NSF Official Listings are current as of Thursday, January 15, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/Plumbing/Listings.asp?Company=C0124129&Standard=014&

Did you know?

The new NSF Product Listings website is available for NSF/ANSI 14-Certified products with a new look and feel. Click on "Try it Now" to check it out!

NSF/ANSI 14
Plastics Piping System Components and Related Materials


Click here for a list of End Use Code Designations.

Click on Product Standards or footnote in blue to view the referenced document



 
The Mosack Group, Inc. 
701 Matthews-Mint Hill Road
Matthews, NC 28105 
United States 
704-847-9191

Facility : Foshan, China

Surface Burning Characteristics of Building Materials

Product Type   Material Type   Trade Name   Product Standard

Tubing# $ * ^ § +++ [G]
 
PEX
 
Apollo/TMG/PurePEX/PureLink
 
ASTM E84

3/8", 1/2" - 2"[1]
WPPW2012   WPPW201   WPPB2034   WPPW2034  
WPPR2034   WPPB2012   WPPR2012  

68PXB100012 1/2"
Flame Spread Index <= 25   Flame Spread Index <= 25  

68PXB100038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB10038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB3001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB5001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB50038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR100012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR100038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR10038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR3001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR5001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR50038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW100012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW100038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW10038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW3001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW5001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW50038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB101 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB1210 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB212 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB234 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB3410 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR101 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR1210 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR212 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR234 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR3410 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW101 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW212 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW234 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW5012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW5034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW51 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW538 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
  tubing is field insulated with 1/2" JM  Microlok HP Hi performance fiberglass insulation
  as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
  between tubing runs.  Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Tubing$ & § +++ [G]
 
PEX
 
Apollo/TMG/PurePEX/PureLink
 
CAN/ULC S102.2

3/8", 1/2" - 2"[1]
WPPW2034   WPPW2012   WPPW201   WPPR2034  
WPPB2012   WPPR2012   WPPB2034  

68PXB100012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB100038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB10038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB3001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB5001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXB50038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR100012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR100038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR10038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR3001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR5001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXR50038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW100012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW100038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW10038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW3001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW5001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

68PXW50038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB10012 1/2"
Flame Spread Rating <= 25   Smoke Developed Classification <= 50  

APPB10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB101 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB1210 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB212 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB234 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB3410 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPB534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR101 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR1210 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR212 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR234 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR3410 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPR534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1001 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW10012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW10034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW101 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW1038 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW201 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW212 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW234 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW2534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW30012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW30034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW50012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW50034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW5012 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW5034 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW51 1"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW512 1/2"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW534 3/4"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

APPW538 3/8"
Flame Spread Index <= 25   Smoke Developed Index <= 50  

[1] Flame Spread Index <= 25
    Smoke Developed Index <= 50
$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
  1/2" - 2" tubing (with insulation),  Flame Spread Index and Smoke Developed Index based
  on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
  insulation as per the pipe manufacturer's installation instructions.  Tubing shall be
  Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * ^ § +++ [1] [G]
 
PEX5106
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877

>= 1/8" SDR 9
APPB1001 1"   APPB10012 1/2"   APPB10034 3/4"   APPB1210 1/2"  
APPB2012 1/2"   APPB2034 3/4"   APPB3001 1"   APPB30012 1/2"  
APPB30034 3/4"   APPB3410 3/4"   APPB50012 1/2"   APPB50034 3/4"  
APPR1001 1"   APPR10012 1/2"   APPR10034 3/4"   APPR1210 1/2"  
APPR2012 1/2"   APPR2034 3/4"   APPR3001 1"   APPR30012 1/2"  
APPR30034 3/4"   APPR3410 3/4"   APPR50012 1/2"   APPR50034 3/4"  
APPW1001 1"   APPW10012 1/2"   APPW10034 3/4"   APPW1012 1/2"  
APPW1034 3/4"   APPW2012 1/2"   APPW2034 3/4"   APPW3001 1"  
APPW30012 1/2"   APPW30034 3/4"   APPW50012 1/2"   APPW50034 3/4"  
APPW51 1"   APPW512 1/2"   APPW514 1/4"   APPW534 3/4"  
APPW538 3/8"  

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Certified for red and white PEX 5106 monowall pipe.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Tubing$ * ^ ¢ § +++ [1] [G]
 
PEX5106
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

>= 1/8" SDR 9
APPB1001 1"   APPB10012 1/2"   APPB10034 3/4"   APPB1210 1/2"  
APPB2012 1/2"   APPB2034 3/4"   APPB3001 1"   APPB30012 1/2"  
APPB30034 3/4"   APPB3410 3/4"   APPB50012 1/2"   APPB50034 3/4"  
APPR1001 1"   APPR10012 1/2"   APPR10034 3/4"   APPR1210 1/2"  
APPR2012 1/2"   APPR2034 3/4"   APPR3001 1"   APPR30012 1/2"  
APPR30034 3/4"   APPR3410 3/4"   APPR50012 1/2"   APPR50034 3/4"  
APPW1001 1"   APPW10012 1/2"   APPW10034 3/4"   APPW1012 1/2"  
APPW1034 3/4"   APPW2012 1/2"   APPW2034 3/4"   APPW3001 1"  
APPW30012 1/2"   APPW30034 3/4"   APPW50012 1/2"   APPW50034 3/4"  
APPW51 1"   APPW512 1/2"   APPW514 1/4"   APPW534 3/4"  
APPW538 3/8"  

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Certified for red and white PEX 5106 monowall pipe.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Tubing# * § +++ [2] [G]
 
PEX5106
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877
68PXB100012 1/2"   68PXB100038 3/8"   68PXB1001 1"   68PXB10012 1/2"  
68PXB10034 3/4"   68PXB10038 3/8"   68PXB1012 1/2"   68PXB1034 3/4"  
68PXB201 1"   68PXB2012 1/2"   68PXB2034 3/4"   68PXB3001 1"  
68PXB30012 1/2"   68PXB30034 3/4"   68PXB5001 1"   68PXB50012 1/2"  
68PXB50034 3/4"   68PXB50038 3/8"   68PXR100012 1/2"   68PXR100038 3/8"  
68PXR1001 1"   68PXR10012 1/2"   68PXR10034 3/4"   68PXR10038 3/8"  
68PXR1012 1/2"   68PXR1034 3/4"   68PXR201 1"   68PXR2012 1/2"  
68PXR2034 3/4"   68PXR3001 1"   68PXR30012 1/2"   68PXR30034 3/4"  
68PXR5001 1"   68PXR50012 1/2"   68PXR50034 3/4"   68PXR50038 3/8"  
68PXW100012 1/2"   68PXW100038 3/8"   68PXW1001 1"   68PXW10012 1/2"  
68PXW10034 3/4"   68PXW10038 3/8"   68PXW1012 1/2"   68PXW1034 3/4"  
68PXW201 1"   68PXW2012 1/2"   68PXW2034 3/4"   68PXW3001 1"  
68PXW30012 1/2"   68PXW30034 3/4"   68PXW5001 1"   68PXW50012 1/2"  
68PXW50034 3/4"   68PXW50038 3/8"   APPB101 1"   APPB1210 1/2"  
APPB212 1/2"   APPB234 3/4"   APPB3410 3/4"   APPB512 1/2"  
APPB534 3/4"   APPR1210 1/2"   APPR212 1/2"   APPR234 3/4"  
APPR3410 3/4"   APPR512 1/2"   APPR534 3/4"   APPW101 1"  
APPW1038 3/8"   APPW14RISER 1/4"   APPW201 1"   APPW212 1/2"  
APPW234 3/4"   APPW2512 1/2"   APPW2534 3/4"   APPW5012 1/2"  
APPW5034 3/4"  

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[2] Certified for the following:
    1. Monowall pipe [PEX 5106]: 1/8" - 3"
    2. 2-layer skinned pipe for Red, Blue, White [PEX 5106]: 1/2", 5/8", 3/8", 3/4", 1", 1
    1/4", 1 1/2", 2"sizes only.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Tubing# § +++ [2] [G]
 
PEX5106
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5
68PXB100012 1/2"   68PXB100038 3/8"   68PXB1001 1"   68PXB10012 1/2"  
68PXB10034 3/4"   68PXB10038 3/8"   68PXB1012 1/2"   68PXB1034 3/4"  
68PXB201 1"   68PXB2012 1/2"   68PXB2034 3/4"   68PXB3001 1"  
68PXB30012 1/2"   68PXB30034 3/4"   68PXB5001 1"   68PXB50012 1/2"  
68PXB50034 3/4"   68PXB50038 3/8"   68PXR100012 1/2"   68PXR100038 3/8"  
68PXR1001 1"   68PXR10012 1/2"   68PXR10034 3/4"   68PXR10038 3/8"  
68PXR1012 1/2"   68PXR1034 3/4"   68PXR201 1"   68PXR2012 1/2"  
68PXR2034 3/4"   68PXR3001 1"   68PXR30012 1/2"   68PXR30034 3/4"  
68PXR5001 1"   68PXR50012 1/2"   68PXR50034 3/4"   68PXR50038 3/8"  
68PXW100012 1/2"   68PXW100038 3/8"   68PXW1001 1"   68PXW10012 1/2"  
68PXW10034 3/4"   68PXW10038 3/8"   68PXW1012 1/2"   68PXW1034 3/4"  
68PXW201 1"   68PXW2012 1/2"   68PXW2034 3/4"   68PXW3001 1"  
68PXW30012 1/2"   68PXW30034 3/4"   68PXW5001 1"   68PXW50012 1/2"  
68PXW50034 3/4"   68PXW50038 3/8"   APPB101 1"   APPB1210 1/2"  
APPB212 1/2"   APPB234 3/4"   APPB3410 3/4"   APPB512 1/2"  
APPB534 3/4"   APPR1210 1/2"   APPR212 1/2"   APPR234 3/4"  
APPR3410 3/4"   APPR512 1/2"   APPR534 3/4"   APPW101 1"  
APPW1038 3/8"   APPW14RISER 1/4"   APPW201 1"   APPW212 1/2"  
APPW234 3/4"   APPW2512 1/2"   APPW2534 3/4"   APPW5012 1/2"  
APPW5034 3/4"  

# Certified for black, blue, natural, orange, red, and white.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[2] Certified for the following:
    1. Monowall pipe [PEX 5106]: 1/8" - 3"
    2. 2-layer skinned pipe for Red, Blue, White [PEX 5106]: 1/2", 5/8", 3/8", 3/4", 1", 1
    1/4", 1 1/2", 2"sizes only.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Tubing! $ * ^ +++ [G]
 
PEX 5106
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

1/8" - 6" SDR 9
WPPB2012   WPPB2034   WPPR2012   WPPR2034  
WPPW201   WPPW2012   WPPW2034  

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Tubing* ^ ~ ¢ +++ [3] [G]
 
PEX 5106[4]
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

1/2", 5/8", 3/4", 1"
EPPB1012S   EPPB1034S   EPPB2012S   EPPB2034S  
EPPB30034S   EPPR10034S   EPPR1012S   EPPR1034S  
EPPR2012S   EPPR2034S   EPPR30012S   EPPR30034S  
EPPW1001   EPPW10012   EPPW10034   EPPW101  
EPPW1012   EPPW1034   EPPW201   EPPW2012  
EPPW2034   EPPW30012   EPPW30034   EPPW50034  
EPPW51   EPPW512   EPPW534   WEPPW5001  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, F2098.
[4] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Tubing& * ^ ~ ¢ +++ [G]
 
PEX 5106[5]
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

3/8" - 1"
WPPB2012   WPPB2034   WPPR2012   WPPR2034  
WPPW201   WPPW2012   WPPW2034  

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance
  with ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Certified for the following:  			
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8", 3/4" & 1"			
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2", 5/8",
    3/4" & 1"
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Tubing& * ^ ~ ¢ +++ [6] [G]
 
PEX 5306[5]
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

3/8" - 1"
WPPB2012   WPPB2034   WPPR2012   WPPR2034  
WPPW201   WPPW2012   WPPW2034  

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance
  with ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Certified for the following:  			
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8", 3/4" & 1"			
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2", 5/8",
    3/4" & 1"
[6] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Tubing! * ^ § +++ [G]
 
PEX 5106
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877

1/8" - 6" SDR 9
WPPB2012   WPPB2034   WPPR2012   WPPR2034  
WPPW201   WPPW2012   WPPW2034  

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Tubing$ * ^ ~ ¢ +++ [G]
 
PEX 5106[7]
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877

1/2", 5/8", 3/4", 1"
EPPB1012S   EPPB1034S   EPPB2012S   EPPB2034S  
EPPB30034S   EPPR10034S   EPPR1012S   EPPR1034S  
EPPR2012S   EPPR2034S   EPPR30012S   EPPR30034S  
EPPW1001   EPPW10012   EPPW10034   EPPW101  
EPPW1012   EPPW1034   EPPW201   EPPW2012  
EPPW2034   EPPW30012   EPPW30034   EPPW50034  
EPPW51   EPPW512   EPPW534   WEPPW5001  

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[7] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Tubing! * ^ ¢ +++ [G]
 
PEX 5106[6]
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877

3/8" - 1"
WPPB2012   WPPB2034   WPPR2012   WPPR2034  
WPPW201   WPPW2012   WPPW2034  

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[6] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Tubing* ^ ¢ +++ [G]
 
PEX 5306[6]
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877
3/8" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[6] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

[8] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, F2098.

Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing$ * § [1]
 
PEX5106
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877

>= 1/8" SDR 9
APPOB2512 1/2"   APPOB30012 1/2"   APPOB10034 3/4"   APPOB30034 3/4"  

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Certified for red and white PEX 5106 monowall pipe.

Tubing$ * ¢ § [1]
 
PEX5106
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

>= 1/8" SDR 9
APPOB2512 1/2"   APPOB30012 1/2"   APPOB10034 3/4"   APPOB30034 3/4"  

$ Certified for natural, orange, red, and white with oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[1] Certified for red and white PEX 5106 monowall pipe.

Tubing# * § +++ [2]
 
PEX5106
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877
APPOB10012 1/2"   68PXPOB30012 1/2"   68PXPOB50012 1/2"   68PXPOB100012 1/2"  
APPOB1034 3/4"   68PXPOB30034 3/4"   68PXPOB50034 3/4"  

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[2] Certified for the following:
    1. Monowall pipe [PEX 5106]: 1/8" - 3"
    2. 2-layer skinned pipe for Red, Blue, White [PEX 5106]: 1/2", 5/8", 3/8", 3/4", 1", 1
    1/4", 1 1/2", 2"sizes only.

Tubing# * § +++ [2]
 
PEX5106
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877

1/8" - 3"
EPPB2012S   EPPW534   EPPW512   EPPW51  
EPPW50034   EPPW30034   EPPW30012   EPPB1012S  
EPPB1034S   WEPPW5001   EPPB2034S   EPPB30034S  
EPPR10034S   EPPR1012S   EPPR1034S   EPPR2012S  
EPPR2034S   EPPR30012S   EPPR30034S   EPPW1001  
EPPW10012   EPPW10034   EPPW101   EPPW1012  
EPPW1034   EPPW201   EPPW2012   EPPW2034  

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[2] Certified for the following:
    1. Monowall pipe [PEX 5106]: 1/8" - 3"
    2. 2-layer skinned pipe for Red, Blue, White [PEX 5106]: 1/2", 5/8", 3/8", 3/4", 1", 1
    1/4", 1 1/2", 2"sizes only.

Tubing# * § +++ [2]
 
PEX5106
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5
APPOB10012 1/2"   68PXPOB30012 1/2"   68PXPOB50012 1/2"   68PXPOB100012 1/2"  
APPOB1034 3/4"   68PXPOB30034 3/4"   68PXPOB50034 3/4"  

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[2] Certified for the following:
    1. Monowall pipe [PEX 5106]: 1/8" - 3"
    2. 2-layer skinned pipe for Red, Blue, White [PEX 5106]: 1/2", 5/8", 3/8", 3/4", 1", 1
    1/4", 1 1/2", 2"sizes only.

Tubing# * § +++ [2] [8]
 
PEX5106
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

1/8" - 3"
EPPW30034   EPPW50034   EPPW51   EPPW512  
EPPW534   WEPPW5001   EPPB1012S   EPPB1034S  
EPPB2012S   EPPB2034S   EPPB30034S   EPPR10034S  
EPPR1012S   EPPR1034S   EPPR2012S   EPPR2034S  
EPPR30012S   EPPR30034S   EPPW1001   EPPW10012  
EPPW10034   EPPW101   EPPW1012   EPPW1034  
EPPW201   EPPW2012   EPPW2034   EPPW30012  

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[2] Certified for the following:
    1. Monowall pipe [PEX 5106]: 1/8" - 3"
    2. 2-layer skinned pipe for Red, Blue, White [PEX 5106]: 1/2", 5/8", 3/8", 3/4", 1", 1
    1/4", 1 1/2", 2"sizes only.
[8] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, F2098.

Tubing! * ^ §
 
PEX 5106
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877

1/8" - 6" SDR 9
WPPB2012   WPPB2034   WPPR2012   WPPW2034  
WPPW201   WPPW2012   WPPR2034  

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing* ^ ¢ +++ [G]
 
PEX 5106[5]
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877

3/8" - 1"
WPPB2012   WPPB2034   WPPR2012   WPPW2034  
WPPW201   WPPW2012   WPPR2034  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Certified for the following:  			
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8", 3/4" & 1"			
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2", 5/8",
    3/4" & 1"
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5106[7]
 
Apollo/TMG/PurePEX/PureLink
 
ASTM F876/F877

1/2", 5/8", 3/4", 1"
EPPB1012S   WEPPW5001   EPPB2012S   EPPB2034S  
EPPB30034S   EPPR10034S   EPPR1012S   EPPR1034S  
EPPR2012S   EPPR2034S   EPPR30012S   EPPR30034S  
EPPW1001   EPPW10012   EPPW10034   EPPW101  
EPPW1012   EPPW1034   EPPW201   EPPW2012  
EPPW2034   EPPW30012   EPPW30034   EPPW50034  
EPPW51   EPPW512   EPPW534   EPPB1034S  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[7] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Tubing! * ^ §
 
PEX 5106
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

1/8" - 6" SDR 9
WPPB2012   WPPB2034   WPPR2012   WPPW2034  
WPPW201   WPPW2012   WPPR2034  

! Certified for natural, red, white and blue without oxygen barrier.
  Natural - 5006
  Red, white, blue - 5006, 5106, 5206
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Tubing& * ^ ~ ¢ +++ [G]
 
PEX 5106[5]
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

3/8" - 1"
WPPB2012   WPPB2034   WPPR2012   WPPW2034  
WPPW201   WPPW2012   WPPR2034  

& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance
  with ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[5] Certified for the following:  			
    2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8", 3/4" & 1"			
    2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2", 5/8",
    3/4" & 1"
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Tubing* ^ ~ ¢ +++ [G]
 
PEX 5106[7]
 
Apollo/TMG/PurePEX/PureLink
 
CSA B137.5

1/2", 5/8", 3/4", 1"
EPPB1012S   WEPPW5001   EPPB2012S   EPPB2034S  
EPPB30034S   EPPR10034S   EPPR1012S   EPPR1034S  
EPPR2012S   EPPR2034S   EPPR30012S   EPPR30034S  
EPPW1001   EPPW10012   EPPW10034   EPPW101  
EPPW1012   EPPW1034   EPPW201   EPPW2012  
EPPW2034   EPPW30012   EPPW30034   EPPW50034  
EPPW51   EPPW512   EPPW534   EPPB1034S  

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
  red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only. Certified for red,
  white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[7] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

[3] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
    F1960, ASTM F2080, F2098.
[4] PEX 5106 Certified for Red, Blue ,White 2-layer for 1/2", 5/8", 3/4", 1" sizes only.
[6] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked with the following fitting system designations: ASTM F1807, ASTM F2159.

Number of matching Manufacturers is 1
Number of matching Products is 952
Processing time was 0 seconds