Plast-O-Matic Valves, Inc. 
1384 Pompton Avenue
Cedar Grove, NJ 07009 
United States 
973-256-3000
Visit this company's website

Facility : Kaohsiung, Taiwan

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Valves+ @ [G]
 
PVC
 
BT645
 
ASTM F1970

Ball Valve
050EPFL-PV 1/2"   050EPS-PV 1/2"   050EPT-PV 1/2"   050VFL-PV 1/2"  
050VS-PV 1/2"   050VT-PV 1/2"   075EPS-PV 3/4"   075EPT-PV 3/4"  
075VFL-PV 3/4"   075VS-PV 3/4"   075VT-PV 3/4"   100EPFL-PV 1"  
100EPS-PV 1"   100EPT-PV 1"   100VFL-PV 1"   100VS-PV 1"  
100VT-PV 1"   125EPFL-PV 1 1/4"   125EPS-PV 1 1/4"   125EPT-PV 1 1/4"  
125VFL-PV 1 1/4"   125VS-PV 1 1/4"   125VT-PV 1 1/4"   150EPFL-PV 1 1/2"  
150EPS-PV 1 1/2"   150EPT-PV 1 1/2"   150VFL-PV 1 1/2"   150VS-PV 1 1/2"  
150VT-PV 1 1/2"   200EPFL-PV 2"   200EPS-PV 2"   200EPT-PV 2"  
200VFL-PV 2"   200VS-PV 2"   200VT-PV 2"   250EPFL-PV 2 1/2"  
250EPS-PV 2 1/2"   250EPT-PV 2 1/2"   250VFL-PV 2 1/2"   250VS-PV 2 1/2"  
250VT-PV 2 1/2"   300EPFL-PV 3"   300EPS-PV 3"   300EPT-PV 3"  
300VFL-PV 3"   300VS-PV 3"   300VT-PV 3"   400EPFL-PV 4"  
400EPS-PV 4"   400EPT-PV 4"   400VFL-PV 4"   400VS-PV 4"  
400VT-PV 4"  

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
@ Compact Ball Valves 1/2" - 2" rated at 150 PSI and 73°F and 2 1/2" - 4" rated at 100 PSI
  and 73°F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Valves+ @ [G]
 
PVC
 
BT646
 
ASTM F1970

Ball Valves
050EPFL-PV 1/2"   050EPS-PV 1/2"   050EPT-PV 1/2"   050VFL-PV 1/2"  
050VS-PV 1/2"   050VT-PV 1/2"   075EPFL-PV 3/4"   075EPS-PV 3/4"  
075EPT-PV 3/4"   075VFL-PV 3/4"   075VS-PV 3/4"   100EPFL-PV 1"  
100EPS-PV 1"   100EPT-PV 1"   100VFL-PV 1"   100VS-PV 1"  
100VT-PV 1"   125EPFL-PV 1 1/4"   125EPS-PV 1 1/4"   125EPT-PV 1 1/4"  
125VFL-PV 1 1/4"   125VS-PV 1 1/4"   125VT-PV 1 1/4"   150EPFL-PV 1 1/2"  
150EPS-PV 1 1/2"   150EPT-PV 1 1/2"   150VFL-PV 1 1/2"   150VS-PV 1 1/2"  
150VT-PV 1 1/2"   200EPFL-PV 2"   200EPS-PV 2"   200EPT-PV 2"  
200VFL-PV 2"   200VS-PV 2"   200VT-PV 2"   250EPFL-PV 2 1/2"  
250EPS-PV 2 1/2"   250EPT-PV 2 1/2"   250VFL-PV 2 1/2"   250VS-PV 2 1/2"  
250VT-PV 2 1/2"   300EPFL-PV 3"   300EPS-PV 3"   300EPT-PV 3"  
300VFL-PV 3"   300VS-PV 3"   300VT-PV 3"   400EPFL-PV 4"  
400EPS-PV 4"   400EPT-PV 4"   400VFL-PV 4"   400VS-PV 4"  
400VT-PV 4"  

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
@ Compact Ball Valves 1/2" - 2" rated at 150 PSI and 73°F and 2 1/2" - 4" rated at 100 PSI
  and 73°F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Valves+ @ [G]
 
PVC
 
MBV
 
ASTM F1970

Ball Valves
300EPFL-PV 3"   300EPS-PV 3"   300EPT-PV 3"   300VFL-PV 3"  
300VS-PV 3"   300VT-PV 3"   400CFL-PV 4"   400EPFL-PV 4"  
400EPS-PV 4"   400EPT-PV 4"   400VS-PV 4"   400VT-PV 4"  

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
@ Compact Ball Valves 1/2" - 2" rated at 150 PSI and 73°F and 2 1/2" - 4" rated at 100 PSI
  and 73°F.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Valves^ +++ [G]
 
CPVC
 
BT645
 
ASTM F1970

True Union (double Union) ball valve
050EPFL-CP 1/2"   050EPS-CP 1/2"   050EPT-CP 1/2"   050VFL-CP 1/2"  
050VS-CP 1/2"   050VT-CP 1/2"   075EPFL-CP 3/4"   075EPS-CP 3/4"  
075EPT-CP 3/4"   075VFL-CP 3/4"   075VS-CP 3/4"   075VT-CP 3/4"  
100EPFL-CP 1"   100EPS-CP 1"   100EPT-CP 1"   100VFL-CP 1"  
100VS-CP 1"   100VT-CP 1"   125EPFL-CP 1 1/4"   125EPS-CP 1 1/4"  
125EPT-CP 1 1/4"   125VFL-CP 1 1/4"   125VS-CP 1 1/4"   125VT-CP 1 1/4"  
150EPFL-CP 1 1/2"   150EPS-CP 1 1/2"   150EPT-CP 1 1/2"   150VFL-CP 1 1/2"  
150VS-CP 1 1/2"   150VT-CP 1 1/2"   200EPFL-CP 2"   200EPS-CP 2"  
200EPT-CP 2"   200VFL-CP 2"   200VS-CP 2"   200VT-CP 2"  
250EPFL-CP 2 1/2"   250EPS-CP 2 1/2"   250EPT-CP 2 1/2"   250VFL-CP 2 1/2"  
250VS-CP 2 1/2"   250VT-CP 2 1/2"   300EPFL-CP 3"   300EPS-CP 3"  
300EPT-CP 3"   300VFL-CP 3"   300VS-CP 3"   300VT-CP 3"  
400EPFL-CP 4"   400EPS-CP 4"   400EPT-CP 4"   400VFL-CP 4"  
400VS-CP 4"   400VT-CP 4"  

^ Valve rated at 150 PSI and 73°F
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Valves^ +++ [G]
 
CPVC
 
BT646
 
ASTM F1970

True Union (double Union) ball valve
050EPFL-CP 1/2"   050EPS-CP 1/2"   050EPT-CP 1/2"   050VFL-CP 1/2"  
050VS-CP 1/2"   050VT-CP 1/2"   075EPFL-CP 3/4"   075EPS-CP 3/4"  
075EPT-CP 3/4"   075VFL-CP 3/4"   075VS-CP 3/4"   075VT-CP 3/4"  
100EPFL-CP 1"   100EPS-CP 1"   100EPT-CP 1"   100VFL-CP 1"  
100VS-CP 1"   100VT-CP 1"   125EPFL-CP 1 1/4"   125EPS-CP 1 1/4"  
125EPT-CP 1 1/4"   125VFL-CP 1 1/4"   125VS-CP 1 1/4"   125VT-CP 1 1/4"  
150EPFL-CP 1 1/2"   150EPS-CP 1 1/2"   150EPT-CP 1 1/2"   150VFL-CP 1 1/2"  
150VS-CP 1 1/2"   150VT-CP 1 1/2"   200EPFL-CP 2"   200EPS-CP 2"  
200EPT-CP 2"   200VFL-CP 2"   200VS-CP 2"   200VT-CP 2"  
250EPFL-CP 2 1/2"   250EPS-CP 2 1/2"   250EPT-CP 2 1/2"   250VFL-CP 2 1/2"  
250VS-CP 2 1/2"   250VT-CP 2 1/2"   300EPFL-CP 3"   300EPS-CP 3"  
300EPT-CP 3"   300VFL-CP 3"   300VS-CP 3"   300VT-CP 3"  
400EPFL-CP 4"   400EPS-CP 4"   400EPT-CP 4"   400VFL-CP 4"  
400VS-CP 4"   400VT-CP 4"  

^ Valve rated at 150 PSI and 73°F
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.

Valves^ +++ [G]
 
CPVC
 
MBV
 
ASTM F1970

True Union (double Union) ball valve
300EPFL-CP 3"   300EPS-CP 3"   300EPT-CP 3"   300VFL-CP 3"  
300VS-CP 3"   300VT-CP 3"   400CFL-CP 4"   400EPFL-CP 4"  
400EPS-CP 4"   400EPT-CP 4"   400VS-CP 4"   400VT-CP 4"  

^ Valve rated at 150 PSI and 73°F
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
    for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
    state laws and the U.S. Safe Drinking Water Act.