NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, January 15, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/Plumbing/Listings.asp?Company=C0585430&Standard=014&
NSF/ANSI 14
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
| Reliance Worldwide Corporation | |
| 2300 Defoor Hills Road NW | |
| Atlanta, GA 30318 | |
| United States | |
| 770-863-4000 | |
| Visit this company's website |
Facility : # 1 Canada
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard | |||
Tubing$ ? @ ^ ~ § +++ [G] |
PEX 5306 |
Sharkbite® |
ASTM F876/F877 |
|||
| 1/4" - 2" SDR 9 | ||||||
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Tubing? @ ^ ~ § +++ [G] |
PEX 5306 |
Sharkbite® |
AWWA C904 |
|||
| 1/2" - 2" SDR 9 | ||||||
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Tubing$ ? @ ^ ~ ¢ § +++ [1] [G] |
PEX 5306 |
Sharkbite® |
CSA B137.5 |
|||
| 1/4" - 2" SDR 9 | ||||||
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Certified for solid wall red, blue, or white tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F1807,
ASTM F2159, ASSE 1061.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Tubing§ Þ +++ [G] |
PE-RT 4710 |
PROLOCK |
ASTM F2769 |
|||
| 3/8" - 2" SDR 9 | ||||||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
Þ Product is Certified to the International Plumbing Code. Installation in accordance with
the manufacturer's instructions and the requirements of the latest edition of the
International Plumbing Code.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Tubing¢ § Þ +++ [1] [2] [G] |
PE-RT 4710 |
PROLOCK |
CSA B137.18 |
|||
| 3/8" - 2" SDR 9 | ||||||
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
Þ Product is Certified to the International Plumbing Code. Installation in accordance with
the manufacturer's instructions and the requirements of the latest edition of the
International Plumbing Code.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F1807,
ASTM F2159, ASSE 1061.
[2] Tubing certified against CSA B137.18 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F1807,
ASTM F2159, ASTM F1960, ASSE 1061.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Radiant Floor Heating
| Product Type | Material Type | Trade Name | Product Standard | |||
Tubing! $ % ^ ~ § |
PEX 5006 |
SharkBite® |
ASTM F876/F877 |
|||
| 1/4" – 2" SDR 9 | ||||||
! Orange, natural, red, and teal green. $ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic radiant heating system made in accordance with the current version of the ASTM F877 standard intended for a maximum 100 psi water service and a maximum working temperature of 180°F. System components consist of tubing and/or fittings. To be installed in of 180°F. System components consist of tubing and/or fittings. To be installed in accordance with manufacturer’s instructions and the latest edition of the Uniform Plumbing Code™. % This product is barrier tubing. ^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with ASTM F2023. ~ Accepted by NSF for use in residential and commercial construction, including manufactured housing. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. |
||||||
Tubing! $ % ^ ~ ¢ § [1] |
PEX 5006 |
SharkBite® |
CSA B137.5 |
|||
| 1/4" – 2" SDR 9 | ||||||
! Orange, natural, red, and teal green.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in of
180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
% This product is barrier tubing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[1] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
marked, as applicable, with the following fitting system designation(s): ASTM F1807,
ASTM F2159, ASSE 1061.
|
||||||
Number of matching Manufacturers is 1
Number of matching Products is 7
Processing time was 0 seconds