NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, January 15, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/Plumbing/Listings.asp?Company=C0861932&Standard=014&
NSF/ANSI 14
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
| Hydro Master Supply Inc. | |
| 3381 Lawson Boulevard | |
| New York, NY 11572 | |
| United States | |
| 516-870-3812 | |
| Visit this company's website |
Facility : # 1 China
Surface Burning Characteristics of Building Materials
| Product Type | Material Type | Trade Name | Product Standard | |||
Tubing# $ * [1] [2] |
PEX |
HydroMaster |
ASTM E84 |
|||
| 3/8", 1/2" - 2" | ||||||
# The Flame Spread Index and Smoke Developed Index for 1/2"-2" tubing are based on when
tubing is field insulated with 1/2" JM Microlok HP Hi performance fiberglass insulation
as per RIFENG installation instructions. The 3/8" tubing is not insulated.
$ Certified for blue, natural, red, and white without oxygen barrier.
* Flame Spread Index and Smoke Developed Index based on minimum spacing of 18 inches
between tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
[1] Flame Spread Index <= 25
Smoke Developed Index <= 50
[2] ASTM E84, 1/2" - 2" The Flame Spread Index and Smoke Developed Index for 1/2" - 2"
tubing are based on when tubing is field insulated with 1/2" JM Microlok HP Hi
performance fiberglass insulation as per RIFENG installation instructions. The 3/8"
tubing is not insulated.
|
||||||
Tubing$ & [1] [3] |
PEX |
HydroMaster |
CAN/ULC S102.2 |
|||
| 3/8", 1/2" - 2" | ||||||
$ Certified for blue, natural, red, and white without oxygen barrier.
& 3/8" tubing (without insulation) shall be marked [cNSF®-fs ULc S102.2 FS <=25/SD <=50].
1/2" - 2" tubing (with insulation), Flame Spread Index and Smoke Developed Index based
on when the tubing is field insulated with JM Microlok HP Hi Performance Fiberglass
insulation as per the pipe manufacturer's installation instructions. Tubing shall be
Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
[1] Flame Spread Index <= 25
Smoke Developed Index <= 50
[3] 3/8" Tubing (without insulation)
Tubing shall be marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
1/2" through 2" Tubing (with insulation)
Flame Spread Rating and Smoke Developed Classification based on when the tubing is field
insulated with
JM Microlok HP Hi Performance
Fiberglass insulation as per the pipe manufacturer's installation instructions. Tubing
shall be marked
[cNSF®-fs ULc S102.2 FS<=25/SD<=50].
|
||||||
Tubing[4] [5] |
PEX |
HydroMaster |
ASTM E84 |
|||
| 3/8" - 2"[1] | ||||||
[1] Flame Spread Index <= 25
Smoke Developed Index <= 50
[4] Certified for red and white PEX 5106 monowall pipe.
[5] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
insulated with 1/2"
JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation
instructions. Flame
Spread Index and Smoke Developed Index based on minimum spacing of 18 inches between
tubing runs. Tubing shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
|
||||||
Tubing[4] [6] |
PEX |
HydroMaster |
CAN/ULC S102.2 |
|||
| 3/8" - 2"[1] | ||||||
[1] Flame Spread Index <= 25
Smoke Developed Index <= 50
[4] Certified for red and white PEX 5106 monowall pipe.
[6] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
insulated with
1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's
installation
instructions. Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
|
||||||
Tubing[7] [8] |
PEX |
HydroMaster |
ASTM E84 |
|||
| 3/8" - 1"[1] | ||||||
[1] Flame Spread Index <= 25
Smoke Developed Index <= 50
[7] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
pipe.
[8] The Flame Spread Index and Smoke Developed Index are based on when tubing is field
insulated with 1/2"
JM Microlok HP Hi performance fiberglass insulation as per RIFENG installation
instructions (all listed
construction/color/size combinations greater than or equal to 3/8" in diameter). Flame
Spread Index and
Smoke Developed Index based on minimum spacing of 18 inches between tubing runs. Tubing
shall be marked [NSF®-fs ASTM E84 FS<=25/SD<=50].
|
||||||
Tubing[7] [9] |
PEX |
HydroMaster |
CAN/ULC S102.2 |
|||
| 3/8" - 1"[1] | ||||||
[1] Flame Spread Index <= 25
Smoke Developed Index <= 50
[7] Certified for blue, red and white PEX 5106 & 5306 2-layer skinned and 4-layer barrier
pipe.
[9] The Flame Spread Index and Smoke Developed Index are based on when the tubing is field
insulated with
1/2" JM Microlok HP Hi Performance Fiberglass insulation as per the pipe manufacturer's
installation
instructions (all listed construction/color/size combinations greater than or equal to
3/8" in
diameter). Tubing shall be Marked [cNSF®-fs ULc S102.2 FS<=25/SD<=50].
|
||||||
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard | |||
Tubing! * ^ § +++ [G] |
PEX 5106 |
HydroMaster |
ASTM F876/F877 |
|||
| 1/8" - 6" SDR 9 | ||||||
! Certified for natural, red, white and blue without oxygen barrier.
Natural - 5006
Red, white, blue - 5006, 5106, 5206
* * Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Tubing! * ^ § +++ [G] |
PEX 5106 |
HydroMaster |
CSA B137.5 |
|||
| 1/8" - 6" SDR 9 | ||||||
! Certified for natural, red, white and blue without oxygen barrier.
Natural - 5006
Red, white, blue - 5006, 5106, 5206
* * Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Tubing* ^ ¢ +++ [1] [G] |
PEX 5106 |
HydroMaster |
ASTM F876/F877 |
|||
| 3/8" - 1" | ||||||
* * Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[1] Certified for the following:
2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8",3/4" & 1"
2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2",
5/8",3/4" & 1"
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Tubing* ^ ¢ +++ [2] [G] |
PEX 5106 |
HydroMaster |
ASTM F876/F877 |
|||
| >= 1/8" | ||||||
* * Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[2] Certified for red and white PEX 5106 monowall pipe.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Tubing* ^ ~ ¢ +++ [1] [G] |
PEX 5106 |
HydroMaster |
CSA B137.5 |
|||
| 3/8" - 1" | ||||||
* * Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[1] Certified for the following:
2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8",3/4" & 1"
2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2",
5/8",3/4" & 1"
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Tubing* ^ ~ ¢ +++ [2] [G] |
PEX 5106 |
HydroMaster - copy |
CSA B137.5 |
|||
| >= 1/8" | ||||||
* * Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes. Certified for
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[2] Certified for red and white PEX 5106 monowall pipe.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Radiant Floor Heating
| Product Type | Material Type | Trade Name | Product Standard | |||
Tubing* ^ ~ ¢ +++ [1] [G] |
PEX 5106 |
HydroMaster |
ASTM F876/F877 |
|||
| 3/8" - 1" | ||||||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.
Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
Certified for red, white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[1] Certified for the following:
2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8", 3/4" &
1"
2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2",
5/8", 3/4" & 1"
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Tubing* ^ ~ ¢ +++ [2] [G] |
PEX 5106 |
HydroMaster |
ASTM F876/F877 |
|||
| >= 1/8" | ||||||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.
Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
Certified for red, white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[2] Certified for red and white PEX 5106 monowall pipe.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Tubing* ^ ~ ¢ +++ [3] [G] |
PEX 5106 |
HydroMaster |
CSA B137.5 |
|||
| 3/8" - 1" | ||||||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.
Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
Certified for red, white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[3] Certified for the following:
2-layer skinned (Natural PEX – White PE) pipe [PEX 5106]: 3/8", 1/2", 5/8", 3/4" &
1"
2-layer skinned (Natural PEX – Red, White or Blue PE) pipe [PEX 5306]: 3/8", 1/2",
5/8", 3/4" & 1"
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Tubing& * ^ ~ ¢ +++ [2] [4] [G] |
PEX 5106 |
HydroMaster |
CSA B137.5 |
|||
| >= 1/8" | ||||||
& Meets the chlorine resistance requirements of ASTM F1281 when tested in accordance with
ASTM F2023.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Certified for Natural non-barrier single layer tubing for 1/8 - 3" sizes.
Certified for red, white, blue 2-layer tubing for 1/2", 5/8", 3/4", 1" sizes only.
Certified for red, white, blue, orange, natural 3-layer tubing for 1/2", 5/8", 3/4", 1"
sizes only.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[2] Certified for red and white PEX 5106 monowall pipe.
[4] Tubing Certified against CSA B137.5 shall include the standard designation(s) of the
fitting system(s) for which the tubing is recommended by the manufacturer and shall be
marked with the following fitting system designations: ASTM F1807, ASTM F2159, ASTM
F1960, ASTM F2080, ASTM F2098, ASSE 1061.
[G] Product is Certified to NSF/ANSI/CAN 372 and conforms with the lead content requirements
for "lead free" plumbing as defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act.
|
||||||
Number of matching Manufacturers is 1
Number of matching Products is 16
Processing time was 0 seconds