NSF Product and Service Listings

These NSF Official Listings are current as of Thursday, September 26, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/Plumbing/Listings.asp?PlantState=PA&

Did you know?

The new NSF Product Listings website is available for NSF/ANSI 14-Certified products with a new look and feel. Click on "Try it Now" to check it out!

NSF/ANSI 14
Plastics Piping System Components and Related Materials


Click here for a list of End Use Code Designations.

Click on Product Standards or footnote in blue to view the referenced document



 
Charlotte Pipe & Foundry Company 
Plastics Division
4210 Old Charlotte Highway 
P.O. Box 1339 
Monroe, NC 28111-1339 
United States 
704-291-3218
Visit this company's website

Facility : Muncy, PA

Drain, Waste, and Vent - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe§
 
MLTPL
 
Charlotte Pipe®
 
ASTM F1488
1 1/4" - 6" DR 24

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe* §
 
PVC
 
Charlotte Pipe®***
 
ASTM D2665
1 1/4" - 12" Sch 40

* Socketed and gasketed bell ends are not tested or Listed by NSF for this production
  facility.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
*** These pipe products may include the production location code PLPA in the trade name.

Pipe¢ §
 
ABS
 
Charlotte Pipe®***
 
ASTM F628
1 1/4" - 6" Sch 40

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
*** These pipe products may include the production location code PLPA in the trade name.

Pipe~
 
ABS
 
Charlotte Pipe®***
 
CSA B181.1
1 1/4" - 6" Sch 40

~ Product is authorized to bear the cNSF Mark.
*** These pipe products may include the production location code PLPA in the trade name.

Pipe§
 
PVC
 
Charlotte Pipe®***
 
ASTM F891
1 1/2" - 8" Sch 40
10", 12" Sch 40

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
*** These pipe products may include the production location code PLPA in the trade name.

Pipe
 
PVC
 
Charlotte Pipe®***
 
ASTM D2949
3 1/4"

*** These pipe products may include the production location code PLPA in the trade name.


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* + § [G]
 
PVC
 
Charlotte Pipe®***
 
ASTM D1785
1/2" - 6" Sch 40
1/2" - 8" Sch 80
8" - 12" Sch 40

* Sockets and gasketed bell ends are not tested or Listed by NSF for this production
  facility.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
*** These pipe products may include the production location code PLPA in the trade name.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* + § [G]
 
PVC
 
Charlotte Pipe®***
 
ASTM D2241
1/2" SDR 13.5
3/4" - 2" SDR 21
1" - 6" SDR 26
2 1/2" - 12" SDR 32.5
4" - 12" SDR 41

* Sockets and gasketed bell ends are not tested or Listed by NSF for this production
  facility.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
*** These pipe products may include the production location code PLPA in the trade name.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Well Casings

Product Type   Material Type   Trade Name   Product Standard

Well Casings+ [G]
 
PVC
 
Charlotte Pipe®***
 
ASTM F480
2" - 12" Sch 40

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
*** These pipe products may include the production location code PLPA in the trade name.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Cresline Plastic Pipe Co., Inc. 
600 Cross Pointe Boulevard 
Evansville, IN 47715 
United States 
270-826-8317

Facility : Mechanicsburg, PA

Drain, Waste, and Vent - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe*
 
PVC
 
Cresline® PVC DWV
 
ASTM D2665
1 1/4" - 8" Sch 40

* Sockets and gasketed bell ends are not tested or Listed by NSF for this production
  facility.

Pipe*
 
PVC
 
 
ASTM D2665
1 1/4" - 8" Sch 40

* Sockets and gasketed bell ends are not tested or Listed by NSF for this production
  facility.

Pipe
 
PVC
 
Cresline®
 
ASTM F891
1 1/2" - 8"


Irrigation - Pipe and Fittings

Product Type   Material Type   Trade Name Product Standard

Pipe
 
PE 4710
 
Cresline® HD
 
ASTM D2239
3/4" - 2" SIDR 15
1" - 2" SIDR 19

Pipe
 
PE 4710
 
Cresline® CE Blue®
 
SE 30288
3/4" - 2" SIDR 15
1" - 2" SIDR 19


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe+ [G]
 
PE 4710
 
Cresline® CE Blue®
 
ASTM D2239
3/4" - 2" SIDR 7
3/4" - 2" SIDR 9
1/2" - 2" SIDR 11.5[1]

[1] These pipe sizes are not certified for use in potable water applications containing
    oxidizing disinfectants and shall not be marked with a CC oxidative resistance
    classification. 
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing+ [G]
 
PE 4710
 
Cresline® CE Blue®
 
ASTM D2737
3/4" - 2" SIDR 9

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing+ [G]
 
PE 4710
 
Cresline® CE Blue®
 
AWWA C901
3/4" - 2" SIDR 9

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe+ [G]
 
PE 4710
 
Cresline® HD
 
ASTM D2239
3/4" - 2" SIDR 7
3/4" - 2" SIDR 9
1/2" - 2" SIDR 11.5[1]

[1] These pipe sizes are not certified for use in potable water applications containing
    oxidizing disinfectants and shall not be marked with a CC oxidative resistance
    classification. 
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing+ [G]
 
PE 4710
 
Cresline® HD-CTS
 
ASTM D2737
3/4" - 2" SDR 9

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing+ [G]
 
PE 4710
 
Cresline® HD-CTS
 
AWWA C901
3/4" - 2" SDR 9

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* + [G]
 
PVC
 
Cresline® PVC
 
ASTM D1785
1/2" - 8" Sch 40
1/2" - 8" Sch 80

* Sockets and gasketed bell ends are not tested or Listed by NSF for this production
  facility.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* + [G]
 
PVC
 
 
ASTM D1785
1/2" - 8" Sch 40
1/2" - 8" Sch 80

* Sockets and gasketed bell ends are not tested or Listed by NSF for this production
  facility.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* + [G]
 
PVC
 
Cresline® PVC
 
ASTM D2241
1/2" - 8" SDR 13.5
1/2" - 8" SDR 26
1/2" - 8" SDR 21
5" SDR 17

* Sockets and gasketed bell ends are not tested or Listed by NSF for this production
  facility.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* + [G]
 
PVC
 
 
ASTM D2241
1/2" - 8" SDR 13.5
1/2" - 8" SDR 26
1/2" - 8" SDR 21
5" SDR 17

* Sockets and gasketed bell ends are not tested or Listed by NSF for this production
  facility.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Well Casings

Product Type   Material Type   Trade Name   Product Standard

Well Casings[G]
 
PVC
 
Cresline®
 
ASTM F480
4" - 8" SDR 26
4" - 8" SDR 21
4 1/2" - 6" SDR 17
2" - 8" Sch 40
6 1/4" DR 27.6
4 1/2" DR 20

[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Georg Fischer Central Plastics LLC 
4949 Joseph Hardin Drive
Dallas, TX 75236 
United States 
469-801-2246

Facility : Titusville, PA

Gas Applications - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe*
 
PE 2708
 
+GF+ DESIGN FLOW
 
ASTM D2513
1/2" CTS - .090 WALL
3/4" CTS - .090 WALL
1 1/8" CTS - .099 WALL, 0.090 WALL
1/2" IPS SDR 9.3
3/4" IPS SDR 11
1" IPS SDR 11
1 1/4" IPS SDR 10, 11
1 1/2" IPS SDR 11
2" IPS SDR 11
3" IPS SDR 11, 11.5
4" IPS SDR 11, 11.5, 13.5

* Product is authorized to bear the cNSF Mark.

Pipe*
 
PE 4710
 
+GF+ DESIGN FLOW
 
ASTM D2513
1/2" CTS - .090 WALL, .062 WALL
3/4" CTS - .090 WALL
1" CTS -.121, .101, .101, .099, .090 WALL
1 1/4" CTS - .090 WALL
3/4" IPS SDR 7.3, 9, 11
1" IPS SDR 7.3, 9, 11
1 1/4" IPS SDR 7.3, 9, 11
1 1/2" IPS SDR 7.3, 9, 11
2" IPS SDR 7.3, 9, 11, 13.5, 15.5, 17
3" IPS SDR 7.3, 9, 11, 13.5, 15.5, 17
4" IPS SDR 7.3, 9, 11, 13.5, 15.5, 17
6" IPS SDR 9, 11, 13.5, 15.5, 17
8" IPS SDR 11, 13.5, 15.5, 17
10" IPS SDR 13.5, 15.5, 17
12" IPS SDR 15.5, 17

* Product is authorized to bear the cNSF Mark.


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe$ + [G]
 
PE 4710
 
+GF+ DESIGN FLOW
 
ASTM D2239
3/4" - 2" SIDR 5.3
3/4" - 2" SIDR 7
3/4" - 2" SIDR 9
1/2" - 3" SIDR 11.5[1]

3/4" - 3" SIDR 15[1]

1/2" - 2" SIDR 19[1]

[1] These pipe sizes are not certified for use in potable water applications containing
    oxidizing disinfectants and shall not be marked with a CC oxidative resistance
    classification.
$ These products also meet the requirements for PE 3408 per ASTM D3350-02a.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe+ [G]
 
PE 4710
 
+GF+ DESIGN FLOW
 
ASTM D2737
3/4" - 2" SDR 9

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe$ + [G]
 
PE 4710
 
+GF+ DESIGN FLOW
 
ASTM D3035
1/2" DR 7[1]

3/4" - 3" DR 7
1/2" DR 9[1]

3/4" - 3" DR 9
1/2" - 3" DR 11[1]

1/2" - 3" DR 13.5[1]

3/4" - 3" DR 15.5[1]

3/4" - 3" DR 17[1]

1" - 3" DR 21[1]

1" - 3" DR 26[1]

1 1/2" - 3" DR 32.5[1]

[1] These pipe sizes are not certified for use in potable water applications containing
    oxidizing disinfectants and shall not be marked with a CC oxidative resistance
    classification.
$ These products also meet the requirements for PE 3408 per ASTM D3350-02a.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe$ + [G]
 
PE 4710
 
+GF+ DESIGN FLOW
 
ASTM F714
4" - 18" IPS DR 7.3
4" - 26" IPS DR 7
4" - 36" IPS DR 9
4" - 42" IPS DR 11
4" - 48" IPS DR 13.5
4" - 54" IPS DR 15.5[2]

4" - 54" IPS DR 17
4" - 54" IPS DR 21
4" - 54" IPS DR 26
4" - 54" IPS DR 32.5
4" - 54" IPS DR 41

[2] Special sizes may be acceptable for engineered applications, due to system conditions or
    special local
    requirements. It is the responsibility of the end user to ensure that the product is
    suitable for the
    intended application.
$ These products also meet the requirements for PE 3408 per ASTM D3350-02a.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe+ [G]
 
PE 4710
 
+GF+ DESIGN FLOW
 
AWWA C901
3/4" - 3" SDR 9

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe$ * + [G]
 
PE 4710
 
+GF+ DESIGN FLOW
 
AWWA C906
4" - 26" IPS DR 7
4" - 28" IPS DR 7.3[2]

4" - 34" IPS DR 9
4" - 42" IPS DR 11
4" - 48" IPS DR 13.5
4" - 54" IPS DR 15.5[2]

4" - 54" IPS DR 17
4" - 54" IPS DR 21
4" - 54" IPS DR 26[2]

4" - 54" IPS DR 32.5[2]

[2] Special sizes may be acceptable for engineered applications, due to system conditions or
    special local
    requirements. It is the responsibility of the end user to ensure that the product is
    suitable for the
    intended application.
$ These products also meet the requirements for PE 3408 per ASTM D3350-02a.
* These products also meet the requirements for PE 3408 per ASTM D3350-02a.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.


 
Georg Fischer LLC 
9271 Jeronimo Road
Irvine, CA 92618 
United States 
610-252-7355
Visit this company's website

Facility : Easton, PA

Drain, Waste, and Vent - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe*
 
PVC
 
+GF+ Harvel® Industrial
 
ASTM D2665
1 1/4" - 24" Sch 40

* Sockets and gasketed bell ends are not tested or Listed by NSF International for this
  production facility.

Pipe*
 
PVC
 
+GF+ Harvel® Industrial PLUS
 
ASTM D2665
1 1/4" - 24" Sch 40

* Sockets and gasketed bell ends are not tested or Listed by NSF International for this
  production facility.


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* + [G]
 
PVC
 
+GF+ Harvel® Industrial
 
ASTM D1785
1/8" - 24" Sch 40
1/8" - 24" Sch 80

* Sockets and gasketed bell ends are not tested or Listed by NSF International for this
  production facility.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* + [G]
 
PVC
 
+GF+ Harvel® Industrial PLUS
 
ASTM D1785
1/8" - 24" Sch 40
1/8" - 24" Sch 80

* Sockets and gasketed bell ends are not tested or Listed by NSF International for this
  production facility.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* + [G]
 
PVC
 
+GF+ HARVEL PVC
 
ASTM D1785
1/8" - 24" Sch 40
1/8" - 24" Sch 80
1/2" - 8" Sch 120

* Sockets and gasketed bell ends are not tested or Listed by NSF International for this
  production facility.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* + [G]
 
PVC
 
 
ASTM D1785
1/2" - 8" Sch 120

* Sockets and gasketed bell ends are not tested or Listed by NSF International for this
  production facility.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* + [G]
 
PVC
 
+GF+ HARVEL PVC
 
ASTM D2241
1/2" SDR 13.5
3/4" - 10" SDR 21
1"- 24" SDR 26
18" SDR 41
20" SDR 41
24" SDR 41

* Sockets and gasketed bell ends are not tested or Listed by NSF International for this
  production facility.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe* + [G]
 
PVC
 
 
ASTM D2241
1/2" SDR 13.5
3/4" - 10" SDR 21
1" - 24" SDR 26
18" SDR 41
20" SDR 41
24" SDR 41

* Sockets and gasketed bell ends are not tested or Listed by NSF International for this
  production facility.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe+ ¢ [G]
 
PVC
 
+GF+ Harvel® Industrial
 
CSA B137.3
1/2" - 24" Sch 80
1/2" - 20" Sch 40

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe+ ¢ [G]
 
PVC
 
+GF+ Harvel® Industrial PLUS
 
CSA B137.3
1/2" - 20" Sch 40
1/2" - 24" Sch 80

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe+ ¢ [G]
 
PVC
 
+GF+ HARVEL PVC
 
CSA B137.3
1/2" - 24" Sch 40
1/2" - 24" Sch 80

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe+ ¢ [G]
 
PVC
 
 
CSA B137.3
1/2" - 24" Sch 40
1/2" - 24" Sch 80

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe¢ +++ [G]
 
CPVC 4120
 
+GF+ HydroKing Commercial
 
ASTM F442
2 1/2" - 8" SDR 11

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe¢ +++ [G]
 
CPVC 4120
 
+GF+ HydroKing Commercial
 
CSA B137.6
1 1/4" - 2 1/2" Sch 80
2 1/2" - 4" SDR 11

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe+++ [G]
 
CPVC 4120
 
ChlorFIT®
 
ASTM F441
1/4" - 24" Sch 40
1/4" - 24" Sch 80

+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe+++ [G]
 
CPVC 4120
 
+GF+ HARVEL CPVC
 
ASTM F441
1/4" - 24" Sch 40
1/4" - 24" Sch 80

+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe+++ [G]
 
CPVC 4120
 
 
ASTM F441
1/4" - 24" Sch 40
1/4" - 24" Sch 80

+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe+++ [G]
 
CPVC 4120
 
SeaCor®
 
ASTM F441
1/4" - 24" Sch 40
1/4" - 24" Sch 80

+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe+++ [G]
 
CPVC 4120
 
 
ASTM F442
3/4" - 3" SDR 13.5

+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe¢ +++ [G]
 
CPVC 4120
 
ChlorFIT®
 
CSA B137.6
3/8" - 2" SDR 11
1 1/4" - 2 1/2" Sch 80

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe¢ +++ [G]
 
CPVC 4120
 
+GF+ HARVEL CPVC
 
CSA B137.6
3/8" - 2" SDR 11
1 1/4" - 2 1/2" Sch 80

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe¢ +++ [G]
 
CPVC 4120
 
 
CSA B137.6
3/8" - 2" SDR 11
1 1/4" - 2 1/2" Sch 80

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe¢ +++ [G]
 
CPVC 4120
 
SeaCor®
 
CSA B137.6
3/8" - 2" SDR 11
1 1/4" - 2 1/2" Sch 80

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Well Casings

Product Type   Material Type   Trade Name   Product Standard

Well Casings** [G]
 
PVC
 
HARVEL PVC
 
ASTM F480
2" - 16" Sch 40
2" - 16" Sch 80
2" - 16" SDR 17
2" - 10" SDR 21
4" - 16" SDR 26

** Sockets and gasketed bell-ends are not tested or Certified by NSF International for this
   production facility.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Well Casings** [G]
 
PVC
 
 
ASTM F480
2" - 16" Sch 40
2" - 16" Sch 80
2" - 16" SDR 17
2" - 10" SDR 21
4" - 16" SDR 26

** Sockets and gasketed bell-ends are not tested or Certified by NSF International for this
   production facility.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
J-M Manufacturing Co., Inc. DBA JM Eagle 
9 Peach Tree Hill Road
Livingston, NJ 07039 
United States 
310-693-8200
Visit this company's website

Facility : # 11 Cochranton, PA

Drain, Waste, and Vent - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe# §
 
PVC
 
J-M Manufacturing
 
ASTM D2665
1 1/4" - 16" Sch 40

# This product may be marked with an alternate trade name: J-M Manufacturing and/or PW
  Eagle and/or [JMM Logo] and/or JM Eagle and/or [JM Eagle Logo].
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe# §
 
PVC
 
J-M Manufacturing
 
ASTM F891
1 1/4" - 8" Sch 40

# This product may be marked with an alternate trade name: J-M Manufacturing and/or PW
  Eagle and/or [JMM Logo] and/or JM Eagle and/or [JM Eagle Logo].
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

NOTE: Only products bearing the NSF Mark are Certified.

Electrical Conduit and Accessories

Product Type   Material Type   Trade Name   Product Standard

PVC Foam Core Conduit#
 
PVC
 
J-M Manufacturing
 
UL 651
3", 4", 6" Sch 40

# This product may be marked with an alternate trade name: J-M Manufacturing and/or PW
  Eagle and/or [JMM Logo] and/or JM Eagle and/or [JM Eagle Logo].

Rigid Conduit#
 
PVC
 
J-M Manufacturing
 
CSA C22.2 No. 211.1
2", 3", 3.5", 4", 5", 6" Type DB2/ES2

# This product may be marked with an alternate trade name: J-M Manufacturing and/or PW
  Eagle and/or [JMM Logo] and/or JM Eagle and/or [JM Eagle Logo].

Rigid Conduit#
 
PVC
 
J-M Manufacturing
 
CSA C22.2 No. 211.2
0.5", 0.75", 1", 1.25", 1.5", 2" Sch 40
3", 4", 5", 6", 8" Sch 40

# This product may be marked with an alternate trade name: J-M Manufacturing and/or PW
  Eagle and/or [JMM Logo] and/or JM Eagle and/or [JM Eagle Logo].

* Complies with requirements for above ground, underground or indoor use; sunlight
  resistance and use with maximum 90°C wire.
NOTE: Only products bearing the NSF Mark are Certified.

Gas Applications - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* §
 
PE 2708
 
JM Eagle
 
ASTM D2513
1/2" CTS SDR 7
3/4" CTS SDR 9.8
1" CTS SDR 9.3
1" CTS SDR 11.5
1" CTS SDR 12.5
1 1/4" CTS SDR 11.5
1 1/4" CTS SDR 15.3
1/2" IPS SDR 9.3
1/2" IPS SDR 11
3/4" IPS SDR 9.3
3/4" IPS SDR 11
1" IPS SDR 11
1 1/4" IPS SDR 10
1 1/4" IPS SDR 11
1 1/2" IPS SDR 11
2" IPS SDR 11
2" IPS SDR 11.5
3" IPS SDR 11
3" IPS SDR 11.5
3" IPS SDR 13.5
3" IPS SDR 17
4" IPS SDR 11
4" IPS SDR 11.5
4" IPS SDR 13.5
4" IPS SDR 17
6" IPS SDR 11
6" IPS SDR 11.5
6" IPS SDR 13.5
6" IPS SDR 17
8" IPS SDR 11
8" IPS SDR 11.5
8" IPS SDR 13.5
10" IPS SDR 13.5
10" IPS SDR 15.5
10" IPS SDR 17
12" IPS SDR 11
12" IPS SDR 11.5
12" IPS SDR 13.5
12" IPS SDR 17

* Gas pipe and tubing limited to outside underground use only.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

NOTE: Only products bearing the NSF Mark are Certified.

Oil and Gas Producing Applications - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe^
 
PE 4710
 
J-M Manufacturing
 
ASTM F2619
1/2" - 24" SDR 7
1/2" - 24" SDR 7.3
1/2" - 30" SDR 9
1/2" - 36" SDR 11
1/2" - 42" SDR 13.5
2" - 54" SDR 17
3" - 63" SDR 21
6" - 63" SDR 26
6" - 63" SDR 32.5

^ This product may be marked with an alternate trade name: JM Eagle or [JM Eagle Logo].


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe+ ^ § [3] [G]
 
PE 4710
 
J-M Manufacturing
 
AWWA C906
4" - 65"

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
^ This product may be marked with an alternate trade name:  JM Eagle, [JM Eagle Logo],
  [JMM Logo], JM Eagle Poly-Flo, JM Eagle-Tough Turf Irrigation Pipe, JM Eagle Geo-Flo,
  and/or JM Eagle-Tough Turf Mainline.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[3] Special sizes may be acceptable for engineered applications, due to system conditions or
    special local requirements.  It is the responsibility of the end user to ensure that the
    product is suitable for the intended application.
    
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe+ ^ § [G]
 
PE 4710
 
J-M Manufacturing
 
ASTM F714
IPS 4" - 65"[3]

[3] Special sizes may be acceptable for engineered applications, due to system conditions or
    special local requirements.  It is the responsibility of the end user to ensure that the
    product is suitable for the intended application.
    
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
^ This product may be marked with an alternate trade name:  JM Eagle, [JM Eagle Logo],
  [JMM Logo], JM Eagle Poly-Flo, JM Eagle-Tough Turf Irrigation Pipe, JM Eagle Geo-Flo,
  and/or JM Eagle-Tough Turf Mainline.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe+ ^ § [G]
 
PE 4710
 
J-M Manufacturing
 
ASTM D2737
3/4" - 2" SDR 7.3
3/4" - 2" SDR 9

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
^ This product may be marked with an alternate trade name:  JM Eagle, [JM Eagle Logo],
  [JMM Logo], JM Eagle Poly-Flo, JM Eagle-Tough Turf Irrigation Pipe, JM Eagle Geo-Flo,
  and/or JM Eagle-Tough Turf Mainline.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe+ ^ § [G]
 
PE 4710
 
J-M Manufacturing
 
ASTM D3035
3/4" - 3" DR 7
3/4" - 3" DR 9

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
^ This product may be marked with an alternate trade name:  JM Eagle, [JM Eagle Logo],
  [JMM Logo], JM Eagle Poly-Flo, JM Eagle-Tough Turf Irrigation Pipe, JM Eagle Geo-Flo,
  and/or JM Eagle-Tough Turf Mainline.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe+ ^ § [G]
 
PE 4710
 
J-M Manufacturing
 
AWWA C901
3/4" - 3" SDR 9

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
^ This product may be marked with an alternate trade name:  JM Eagle, [JM Eagle Logo],
  [JMM Logo], JM Eagle Poly-Flo, JM Eagle-Tough Turf Irrigation Pipe, JM Eagle Geo-Flo,
  and/or JM Eagle-Tough Turf Mainline.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe# + [G]
 
PVC
 
J-M Manufacturing
 
AWWA C900
14" - 48"

# This product may be marked with an alternate trade name: J-M Manufacturing and/or PW
  Eagle and/or [JMM Logo] and/or JM Eagle and/or [JM Eagle Logo].
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe# * + § [G]
 
PVC
 
J-M Manufacturing
 
ASTM D2241
1/2" - 6" SDR 13.5
3/4" - 12" SDR 17
3/4" - 12" SDR 21
1" - 12" SDR 26
1 1/4" - 12" SDR 32.5

# This product may be marked with an alternate trade name: J-M Manufacturing and/or PW
  Eagle and/or [JMM Logo] and/or JM Eagle and/or [JM Eagle Logo].
* Sockets and gasketed bell ends are not tested or Listed by NSF for this
  production facility.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe# * + § [G]
 
PVC
 
J-M Manufacturing
 
ASTM D1785
1/2" - 12" Sch 40
1/2" - 12" Sch 80

# This product may be marked with an alternate trade name: J-M Manufacturing and/or PW
  Eagle and/or [JMM Logo] and/or JM Eagle and/or [JM Eagle Logo].
* Sockets and gasketed bell ends are not tested or Listed by NSF for this
  production facility.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe# + ¢ [G]
 
PVC
 
J-M Manufacturing
 
CSA B137.3
4" - 24" CIOD DR 14[1]

4" - 24" CIOD DR 18[1]

4" - 24" CIOD DR 25[1]

1/2" - 8" Sch 40[2]

1/2" - 8" IPS DR 32.5[2]

[1] Gasketed bell end pipe
[2] Solvent bell end pipe
    
# This product may be marked with an alternate trade name: J-M Manufacturing and/or PW
  Eagle and/or [JMM Logo] and/or JM Eagle and/or [JM Eagle Logo].
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark are Certified.

Reclaimed Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe#
 
PVC
 
J-M Manufacturing
 
AWWA C900
14" - 48"

# This product may be marked with an alternate trade name: PW Eagle and/or (JMM Logo)
  and/or JM Eagle and/or (JM Eagle Logo).

Pipe^
 
PE 4710
 
J-M Manufacturing
 
AWWA C906
4" - 65"

^ This product may be marked with an alternate trade name: JM Eagle, [JM Eagle Logo], [JMM
  Logo], JM Eagle Poly-Flo, JM Eagle-Tough Turf Irrigation Pipe, JM Eagle Geo-Flo, and/or
  JM Eagle-Tough Turf Mainline.			

Pipe^
 
PE 4710
 
J-M Manufacturing
 
ASTM F714
4" - 65"

^ This product may be marked with an alternate trade name: JM Eagle, [JM Eagle Logo], [JMM
  Logo], JM Eagle Poly-Flo, JM Eagle-Tough Turf Irrigation Pipe, JM Eagle Geo-Flo, and/or
  JM Eagle-Tough Turf Mainline.			

NOTE: Only products bearing the NSF Mark are Certified.

Sewer Main - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe#
 
PVC
 
J-M Manufacturing
 
AWWA C900
14" - 48"

# This product may be marked with an alternate trade name: J-M Manufacturing and/or PW
  Eagle and/or [JMM Logo] and/or JM Eagle and/or [JM Eagle Logo].

Pipe^
 
PE 4710
 
J-M Manufacturing
 
AWWA C906
4" - 65"

^ This product may be marked with an alternate trade name: JM Eagle, [JM Eagle Logo], [JMM
  Logo], JM Eagle Poly-Flo, JM Eagle-Tough Turf Irrigation Pipe, JM Eagle Geo-Flo, and/or
  JM Eagle-Tough Turf Mainline.

Pipe^
 
PE 4710
 
J-M Manufacturing
 
ASTM F714
4" - 65"

^ This product may be marked with an alternate trade name: JM Eagle, [JM Eagle Logo], [JMM
  Logo], JM Eagle Poly-Flo, JM Eagle-Tough Turf Irrigation Pipe, JM Eagle Geo-Flo, and/or
  JM Eagle-Tough Turf Mainline.

Pipe# ¢
 
PVC
 
J-M Manufacturing
 
CSA B182.2
4" - 24" DR 26[1]

4" - 24" DR 35[1]

4", 6" DR 26[2]

4", 6" DR 35[2]

[1] Gasketed bell end pipe
[2] Solvent bell end pipe
# This product may be marked with an alternate trade name: J-M Manufacturing and/or PW
  Eagle and/or [JMM Logo] and/or JM Eagle and/or [JM Eagle Logo].
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.

NOTE: Only products bearing the NSF Mark are Certified.


 
Oil Creek Plastics 
East Titusville Road
P.O. Box 385 
Titusville, PA 16354 
United States 
800-537-3661 
814-827-3661
Visit this company's website

Facility : Titusville, PA

Gas Applications - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* §
 
PE 2708
 
OIL CREEK PLASTICS
 
ASTM D2513
1/2" CTS X .090" WALL
1/2" IPS DR 9.3
3/4", 1", 1 1/4", 1 1/2", 2", 3", 4", 6" IPS DR 11
1" CTS X .099" WALL
1 1/4" IPS DR 10
3", 4" IPS DR 11.5
6" IPS DR 13.5

* Gas pipe and tubing limited to outside underground use only.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe* §
 
PE 4710
 
OIL CREEK PLASTICS
 
ASTM D2513
1/2" IPS DR 9.33
3/4" , 1" , 1-1/4" , 1-1/2" , 2" , 3" , 4" IPS DR 11
1/2" CTS x .090" wall
1" CTS x .099" wall
1" CTS x .101" wall
1-1/4" CTS x .121" wall

* Gas pipe and tubing limited to outside underground use only.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe$ +
 
PE 3608/4710
 
Oil Creek Aqua-Jet
 
ASTM D2239
3/4" - 2" SIDR 5.3
3/4" - 2" SIDR 7
3/4" - 2" SIDR 9
1/2" - 2" SIDR 11.5[2]

3/4" - 3" SIDR 15[2]

3/4" - 2" SIDR 19[2]

[2] These pipe sizes shall not be marked with a CC oxidative resistance classification and
    are not certified for use in applications where an oxidative resistance classification
    (e.g. CC1, CC2, CC3), in accordance with ASTM D3350, is required.
$ These products also meet the requirements for PE 3408 per ASTM D3350-02a.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe$ +
 
PE 3608/4710
 
 
ASTM D2239
3/4" - 2" SIDR 5.3
3/4" - 2" SIDR 7
3/4" - 2" SIDR 9
1/2" - 2" SIDR 11.5[2]

3/4" - 3" SIDR 15[2]

3/4" - 2" SIDR 19[2]

[2] These pipe sizes shall not be marked with a CC oxidative resistance classification and
    are not certified for use in applications where an oxidative resistance classification
    (e.g. CC1, CC2, CC3), in accordance with ASTM D3350, is required.
$ These products also meet the requirements for PE 3408 per ASTM D3350-02a.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Tubing# ^ § +++ [4]
 
PE-RT 4710
 
AQUA-PERT
 
ASTM F2769
1/8" - 6" SDR 9

# Certified AQUA-PERT is coextruded natural tubing with a red, blue, or white outer layer.
^ Meets the chlorine resistance requirements of ASTM F2769 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[4] Tubing certified against ASTM F2769 and CSA B137.18 shall include the standard
    designation(s) of the fitting system(s) for which the tubing is recommended by the
    manufacturer, and shall be marked, as applicable, with the following fitting system
    designation(s): ASTM F1807, ASTM F2159 and ASTM F1960.

Tubing# ^ ¢ § +++ [1] [4]
 
PE-RT 4710
 
AQUA-PERT
 
CSA B137.18
1/8" - 6" SDR 9

# Certified AQUA-PERT is coextruded natural tubing with a red, blue, or white outer layer.
^ Meets the chlorine resistance requirements of ASTM F2769 when tested in accordance with
  ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[1] Tubing certified against CSA B137.18 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807,
    ASTM F1960, and ASTM F2159.
[4] Tubing certified against ASTM F2769 and CSA B137.18 shall include the standard
    designation(s) of the fitting system(s) for which the tubing is recommended by the
    manufacturer, and shall be marked, as applicable, with the following fitting system
    designation(s): ASTM F1807, ASTM F2159 and ASTM F1960.

Tubing$ +
 
PE 3608/4710
 
Oil Creek Aqua-Jet (CTS)
 
ASTM D2737
3/4" - 2" SDR 9

$ These products also meet the requirements for PE 3408 per ASTM D3350-02a.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Tubing+
 
PE 3608/4710
 
 
ASTM D2737
3/4" - 2" SDR 9

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe$ +
 
PE 3608/4710
 
Aqua-Blue
 
ASTM D2239
3/4" - 2" SIDR 5.3
3/4" - 2" SIDR 7
3/4" - 2" SIDR 9
1/2" - 2" SIDR 11.5[2]

3/4" - 2" SIDR 15[2]

3/4" - 2" SIDR 19[2]

[2] These pipe sizes shall not be marked with a CC oxidative resistance classification and
    are not certified for use in applications where an oxidative resistance classification
    (e.g. CC1, CC2, CC3), in accordance with ASTM D3350, is required.
$ These products also meet the requirements for PE 3408 per ASTM D3350-02a.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+
 
PE 3608/4710
 
Aqua-Blue
 
ASTM D2737
3/4" - 2" SDR 9

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Tubing$ +
 
PE 3608/4710
 
Oil Creek Aqua-Jet (OD)
 
ASTM D3035
1/2" DR 7[2]

1/2" DR 9[2]

1/2" - 3" DR 11[2]

1/2" - 3" DR 13.5[2]

3/4" - 3" DR 7
3/4" - 3" DR 9
3/4" - 3" DR 15.5[2]

3/4" - 3" DR 17[2]

1" - 3" DR 21[2]

[2] These pipe sizes shall not be marked with a CC oxidative resistance classification and
    are not certified for use in applications where an oxidative resistance classification
    (e.g. CC1, CC2, CC3), in accordance with ASTM D3350, is required.
$ These products also meet the requirements for PE 3408 per ASTM D3350-02a.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Tubing$ +
 
PE 3608/4710
 
Oil Creek Aqua-Jet (OD)
 
ASTM F714
4" - 8" DR 7
4" - 8" DR 7.3
4" - 8" DR 9
4" - 8" DR 11
4" - 8" DR 13.5
4" - 8" DR 15.5[3]

4" - 8" DR 17
4" - 8" DR 21

[3] Special sizes may be acceptable for engineered applications, due to system conditions or
    special local requirements. It is the responsibility of the end user to ensure the
    product is suitable for the intended application.
$ These products also meet the requirements for PE 3408 per ASTM D3350-02a.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing! * ¥ [1] [2] [3]
 
PE-RT PE 2708
 
Heatflex
 
ASTM F2623
5/16" SDR 9
3/8" SDR 9
1/2" SDR 9
5/8" SDR 9
3/4" SDR 9
1" SDR 9

! Heatflex/[Oil Creek Plastics Oil Rig Logo] PE-RT pipe is orange in color.
* Product is barrier tubing.
¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with
  the manufacturer's instructions and the requirements of the latest edition of the
  Uniform Mechanical Code™.
[1] This barrier tubing product has been evaluated against the performance requirements of
    ASTM F2623.  This product is not NSF Certified for use in a potable water distribution
    system.  This product has been evaluated for use in radiant floor heating (NSF-rfh)
    applications only.
[2] Meets the chlorine resistance requirements of ASTM F2623 when tested in accordance with
    ASTM F2023.
[3] Tubing certified against ASTM F2623 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807 and
    ASTM F2159.

Tubing! * ¥ [1] [2] [3]
 
PE-RT PE 2708
 
PERTCO
 
ASTM F2623
5/16" SDR 9
3/8" SDR 9
1/2" SDR 9
5/8" SDR 9
3/4" SDR 9
1" SDR 9

! Heatflex/[Oil Creek Plastics Oil Rig Logo] PE-RT pipe is orange in color.
* Product is barrier tubing.
¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with
  the manufacturer's instructions and the requirements of the latest edition of the
  Uniform Mechanical Code™.
[1] This barrier tubing product has been evaluated against the performance requirements of
    ASTM F2623.  This product is not NSF Certified for use in a potable water distribution
    system.  This product has been evaluated for use in radiant floor heating (NSF-rfh)
    applications only.
[2] Meets the chlorine resistance requirements of ASTM F2623 when tested in accordance with
    ASTM F2023.
[3] Tubing certified against ASTM F2623 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807 and
    ASTM F2159.

Tubing* ¥ ‡ [1] [2] [3]
 
PE-RT PE 2708
 
Propak Heatflex
 
ASTM F2623
5/16" SDR 9
3/8" SDR 9
1/2" SDR 9
5/8" SDR 9
3/4" SDR 9
1" SDR 9

* Product is barrier tubing.
¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with
  the manufacturer's instructions and the requirements of the latest edition of the
  Uniform Mechanical Code™.
‡ Propak Heatflex/[Oil Creek Plastics Oil Rig Logo] PE-RT pipe is orange in color.
[1] This barrier tubing product has been evaluated against the performance requirements of
    ASTM F2623.  This product is not NSF Certified for use in a potable water distribution
    system.  This product has been evaluated for use in radiant floor heating (NSF-rfh)
    applications only.
[2] Meets the chlorine resistance requirements of ASTM F2623 when tested in accordance with
    ASTM F2023.
[3] Tubing certified against ASTM F2623 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807 and
    ASTM F2159.

Tubing! * ¥ ‡ [1] [2] [3]
 
PE-RT PE 2708
 
 
ASTM F2623
5/16" SDR 9
3/8" SDR 9
1/2" SDR 9
5/8" SDR 9
3/4" SDR 9
1" SDR 9

! Heatflex/[Oil Creek Plastics Oil Rig Logo] PE-RT pipe is orange in color.
* Product is barrier tubing.
¥ Product is Certified to the Uniform Mechanical Code™. Installation in accordance with
  the manufacturer's instructions and the requirements of the latest edition of the
  Uniform Mechanical Code™.
‡ Propak Heatflex/[Oil Creek Plastics Oil Rig Logo] PE-RT pipe is orange in color.
[1] This barrier tubing product has been evaluated against the performance requirements of
    ASTM F2623.  This product is not NSF Certified for use in a potable water distribution
    system.  This product has been evaluated for use in radiant floor heating (NSF-rfh)
    applications only.
[2] Meets the chlorine resistance requirements of ASTM F2623 when tested in accordance with
    ASTM F2023.
[3] Tubing certified against ASTM F2623 shall include the standard designation(s) of the
    fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
    marked, as applicable, with the following fitting system designation(s): ASTM F1807 and
    ASTM F2159.



 
Rheogistics, A Division of IGI 
50 Salome Drive
Toronto, ON M1S 2A8 
Canada 
416-293-4151

Facility : Titusville, PA

Ingredient Suppliers

Product Type Trade Name Max Use Level (phr)
Combination Ingredient Package+ [1] [3] [9] Synertive L355 0.68 - 1.68
Paraffin Wax+ [2] Synertive RX-165 0.6 - 1.5
Paraffin Wax+ [2] Synertive RX-165 Classic 0.6 - 1.5
Combination Ingredient Package[1] [3] [4] Synertive RX-310 0.54 - 1.66
Combination Ingredient Package[1] [3] [5] Synertive RX-313 0.8 - 1.73
Combination Ingredient Package[1] [3] [6] Synertive RX-315-S 0.7 - 1.77
Combination Ingredient Package[1] [3] [7] Synertive RX-320 0.74 - 1.6
Combination Ingredient Package[1] [3] [8] Synertive RX-320-S 0.75 - 1.5

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Use of this ingredient in NSF Certified products requires prior authorization from NSF,
    unless user is an authorized holder of the PPI PVC Range Composition.
[2] Certified to NSF/ANSI 14 and also approved in Table 4A of the PPI PVC Range Composition.
     Approved for a use range of 0.60 - 1.5 phr.
[3] For PPI PVC Range Composition holders, see the PPI PVC Range Composition for individual
    ingredient contributions.  Additional amounts of other approved ingredients can be
    added, but the total combined percentage cannot exceed 100% of the allowable phr.
[4] Certified to NSF/ANSI 14 and also approved in Table 10A of the PPI PVC Range
    Composition. Approved for a use range of 0.54 - 1.66 phr.
[5] Certified to NSF/ANSI 14 and also approved in Table 10A of the PPI PVC Range
    Composition. Approved for a use range of 0.8 - 1.73 phr.
[6] Certified to NSF/ANSI 14 and also approved in Table 10A of the PPI PVC Range
    Composition. Approved for a use range of 0.7 - 1.77 phr.
[7] Certified to NSF/ANSI 14 and also approved in Table 10A of the PPI PVC Range
    Composition. Approved for a use range of 0.74 - 1.6 phr.
[8] Certified to NSF/ANSI 14 and also approved in Table 10A of the PPI PVC Range
    Composition. Approved for a use range of 0.75 - 1.5 phr.
[9] Certified to NSF/ANSI 14 and also approved in Table 10A of the PPI PVC Range
    Composition. Approved for a use range of 0.68 - 1.68 phr.



SONNEBORN, LLC 
100 Sonneborn Lane
Petrolia, PA 16050 
United States 
877-948-2688 

Facility : Petrolia, PA

Ingredient Suppliers

Product Type Trade Name Max Use Level (phr)
Paraffin Wax Functional Equivalent+ [1] [2] [3] HYDROBRITE PVC OIL 2.00

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Certified to NSF/ANSI 14 and also approved in Table 4B of the PPI PVC Range Composition.
     Approved for a use range of1.00 - 2.00 phr.
[2] Cannot be used with other functional equivalent ingredients.
[3] Use of this ingredient in NSF Certified products requires prior authorization from NSF,
    unless user is an authorized holder of the PPI PVC Range Composition.



 
The Mosack Group 
701 Matthews Mint-Hill Road
Matthews, NC 28105 
United States 
888-229-2874
Visit this company's website

Facility : Brave, PA

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Fittings¢ § +++ [G]
 
Brass
 
AF PEX LEADFREE
 
ASTM F1807

MPT x PEX Barb Elbow
3/8" - 2"  

Male Sweat x PEX Barb
3/8" - 2"  

PEX Barb Adapter
3/8" - 2"  

PEX Barb Coupling
3/8" - 2"  

PEX Barb Elbow
3/8" - 2"  

PEX Barb Plug
3/8" - 2"  

PEX Barb Reducing Coupling
3/8" - 2"  

PEX Barb Reducing Elbow
3/8" - 2"  

PEX Barb Reducing Tee
3/8" - 2"  

PEX Barb Swivel Adapters
3/8" - 3/4"  

PEX Barb Tee
3/8" - 2"  

PEX Barb x Compression Adapter
3/8" - 3/4"  

PEX Barb x Cu Sweat Elbow
3/8" - 2"  

PEX Barb x FIP Swivel Adapter
3/8" - 2"  

PEX Barb x FPT Adapter
3/8" - 2"  

PEX Barb x FPT Drop Ear Elbow
1/2" - 3/4"  

PEX Barb x Female Sweat Adapter
3/8" - 2"  

PEX Barb x MPT Adapter
3/8" - 2"  

PEX Barb x PB Tube Coupling
3/8" - 1"  

PEX Barb x PE Tube Coupling
3/8" - 1"  

PEX Barb x Swivel Adapter
3/8" - 2"  

Plug Seal Manifold
3/8" - 2"   

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Fittings¢ § +++ [G]
 
Brass
 
AF PEX LEADFREE
 
CSA B137.5

MPT x PEX Barb Elbow
3/8" - 2"  

Male Sweat x PEX Barb
3/8" - 2"  

PEX Barb Adapter
3/8" - 2"  

PEX Barb Coupling
3/8" - 2"  

PEX Barb Elbow
3/8" - 2"  

PEX Barb Plug
3/8" - 2"  

PEX Barb Reducing Coupling
3/8" - 2"  

PEX Barb Reducing Elbow
3/8" - 2"  

PEX Barb Reducing Tee
3/8" - 2"  

PEX Barb Swivel Adapters
3/8" - 3/4"  

PEX Barb Tee
3/8" - 2"  

PEX Barb x Compression Adapter
3/8" - 3/4"  

PEX Barb x Cu Sweat Elbow
3/8" - 2"  

PEX Barb x FIP Swivel Adapter
3/8" - 2"  

PEX Barb x FPT Adapter
3/8" - 2"  

PEX Barb x FPT Drop Ear Elbow
1/2" - 3/4"  

PEX Barb x Female Sweat Adapter
3/8" - 2"  

PEX Barb x MPT Adapter
3/8" - 2"  

PEX Barb x PB Tube Coupling
3/8" - 1"  

PEX Barb x PE Tube Coupling
3/8" - 1"  

PEX Barb x Swivel Adapter
3/8" - 2"  

Plug Seal Manifold
3/8" - 2"   

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    



 
Westlake Pipe & Fittings Corporation 
The Westlake Center
2801 Post Oak Boulevard, Suite 650 
Houston, TX 77056 
United States 
800-999-7473 
713-585-2621

Facility : Leola, PA

Drain, Waste, and Vent - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe[1] [2]
 
PVC
 
Westlake Pipe & Fittings
 
ASTM D2665
1 1/4" - 12" Sch 40

[1] Product may also be marked with trade designation Westlake Canada, Inc. DBA Westlake
    Pipe & Fittings.
[2] Sockets and gasketed bell ends are not tested or Listed by NSF for this production
    facility.

Pipe[1]
 
PVC
 
Westlake Pipe & Fittings
 
ASTM D2949
3.25"

[1] Product may also be marked with trade designation Westlake Canada, Inc. DBA Westlake
    Pipe & Fittings.

Pipe[1]
 
PVC
 
Westlake Pipe & Fittings
 
ASTM F3128
1 1/4" - 6"

[1] Product may also be marked with trade designation Westlake Canada, Inc. DBA Westlake
    Pipe & Fittings.

Pipe[1]
 
PVC
 
NAPCOREtm
 
ASTM F3128
1 1/4" - 6"

[1] Product may also be marked with trade designation Westlake Canada, Inc. DBA Westlake
    Pipe & Fittings.

Pipe[1]
 
PVC
 
Westlake Pipe & Fittings
 
ASTM F891
1 1/4" - 6" Sch 40

[1] Product may also be marked with trade designation Westlake Canada, Inc. DBA Westlake
    Pipe & Fittings.

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.

Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe+ [1] [2] [G]
 
PVC
 
Westlake Pipe & Fittings
 
ASTM D1785
1/2" - 12" Sch 40
1/2" - 12" Sch 80

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product may also be marked with trade designation Westlake Canada, Inc. DBA Westlake
    Pipe & Fittings.
[2] Sockets and gasketed bell ends are not tested or Listed by NSF for this production
    facility.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Pipe+ [1] [2] [G]
 
PVC
 
Westlake Pipe & Fittings
 
ASTM D2241
1/2" - 6" SDR 13.5
>= 3/4" SDR 17
>= 3/4" SDR 21
>= 1" SDR 26
>= 1" SDR 32.5
>= 3" SDR 41

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.
[1] Product may also be marked with trade designation Westlake Canada, Inc. DBA Westlake
    Pipe & Fittings.
[2] Sockets and gasketed bell ends are not tested or Listed by NSF for this production
    facility.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
      documentation shipped with the product are Certified.

Well Casings

Product Type   Material Type   Trade Name   Product Standard

Well Casings[1] [2] [G]
 
PVC
 
Westlake Pipe & Fittings
 
ASTM F480
2" - 12" Sch 40
2" - 4 1/2" SDR 32.5
4 1/2" SDR 17
6 1/8" ID SDR 21
6 1/4" DR 27.6

[1] Product may also be marked with trade designation Westlake Canada, Inc. DBA Westlake
    Pipe & Fittings.
[2] Sockets and gasketed bell ends are not tested or Listed by NSF for this production
    facility.
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

NOTE: Only products bearing the NSF Mark on the product,product packaging, and/or
      documentation shipped with the product are Certified.


 
WL Plastics Corporation 
3575 Lone Star Circle
Suite 300 
Fort Worth, TX 76177 
United States 
682-831-2727
Visit this company's website

Facility : Titusville, PA

Gas Applications - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe§
 
PE 2708
 
WL Plastics PA/WLP PA
 
ASTM D2513
1/2" CTS 0.090 WALL
3/4" CTS 0.090 WALL
1” CTS 0.090 WALL, 0.099 WALL, 0.101 WALL
1-1/4” CTS 0.062 WALL, 0.090 WALL, 0.121 WALL SDR 9.3
1/2" IPS SDR 9, 9.3, 9.33, 11 SDR 11
3/4" IPS SDR 11 SDR 11
1” IPS SDR 11 SDR 10, 11
1-1/4” IPS SDR 10, 11 SDR 11
1-1/2" IPS SDR 11 SDR 11
2” IPS SDR 11, 13.5 SDR 11, 11.5
3” IPS SDR 9, 11, 11.5, 13.5 SDR 11, 11.5, 13.5
4” IPS SDR 9, 11, 11.5, 13.5, 17 SDR 11, 11.5, 13.5
6” IPS SDR 9, 11, 11.5, 13.5, 17 SDR 11, 11.5, 13.5
8” IPS SDR 9, 11, 11.5, 13.5, 17 SDR 11, 11.5, 13.5

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe§
 
PE 4710
 
WL Plastics PA/WLP PA
 
ASTM D2513
1/2" CTS 0.090 WALL
3/4" CTS 0.090 WALL
1” CTS 0.090 WALL, 0.099 WALL, 0.101 WALL, 0.121 WALL
1-1/4” CTS 0.090 WALL, 0.121 WALL
3/4" IPS SDR 7.3, 9, 11 SDR 7.3, 9, 11
1” IPS SDR 7, 7.3, 9, 11 SDR 7.3, 9, 11
1-1/4” IPS SDR 7, 7.3, 9, 10, 11 SDR 7.3, 9, 11
1-1/2" IPS SDR 7, 7.3, 9, 11 SDR 7.3, 9, 11
2” IPS SDR 7, 7.3, 9, 11, 13.5, 15.5, 17 SDR 7.3, 9, 11, 13.5, 15.5, 17
3” IPS SDR 7, 7.3, 9, 11, 11.5, 13.5, 15.5, 17 SDR 7.3, 9, 11, 13.5, 15.5, 17
4” IPS SDR 7, 7.3, 9, 11, 11.5, 13.5, 15.5, 17 SDR 7.3, 9, 11, 13.5, 15.5, 17
6” IPS SDR 7, 7.3, 9, 11, 11.5, 13.5, 15.5, 17 SDR 9, 11, 13.5, 15.5, 17
8” IPS SDR 7, 7.3, 9, 11, 11.5, 13.5, 15.5, 17 SDR 11, 13.5, 15.5, 17
10” IPS SDR 7, 9, 11, 13,5, 15.5, 17 SDR 13.5, 15.5, 17
12” IPS SDR 7, 9, 11, 13.5, 15.5, 17 SDR 15.5, 17

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.

Pipe¢
 
PE 2708
 
WL Plastics PA/WLP PA
 
CSA B137.4
1/2" CTS .090 wall
1" CTS .099 wall
1 1/4" SDR 10
3/4" - 2" SDR 11

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe+
 
PE 4710
 
WL Plastics PA/WLP PA
 
ASTM D2239
3/4" - 2" SIDR 5.3
3/4" - 2" SIDR 7
3/4" - 2" SIDR 9
1/2" - 3" SIDR 11.5[1]

3/4" - 3" SIDR 15[1]

1/2" - 2" SIDR 19[1]

[1] These pipe sizes are not certified for use in potable water applications containing
    oxidizing disinfectants and shall not be marked with a CC oxidative resistance
    classification.						
    
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+
 
PE 4710
 
WL Plastics PA/WLP PA
 
ASTM D3035
1/2" DR 7[1]

3/4" - 3" DR 7
1/2" DR 9[1]

3/4" - 3" DR 9
1/2" - 3" DR 11[1]

1/2" - 3" DR 13.5[1]

3/4" - 3" DR 15.5[1]

3/4" - 3" DR 17[1]

1" - 3" DR 21[1]

1" - 3" DR 26[1]

1 1/2" - 3" DR 32.5[1]

[1] These pipe sizes are not certified for use in potable water applications containing
    oxidizing disinfectants and shall not be marked with a CC oxidative resistance
    classification.						
    
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+
 
PE 4710
 
WL Plastics PA/WLP PA
 
ASTM D2737
3/4" - 2" SDR 9

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+
 
PE 4710
 
WL Plastics PA/WLP PA
 
ASTM F714
4" - 18" IPS DR 7.3
4" - 26" IPS DR 7
4" - 36" IPS DR 9
4" - 42" IPS DR 11
4" - 48" IPS DR 13.5
4" - 54" IPS DR 15.5[2]

4" - 54" IPS DR 17
4" - 54" IPS DR 21
4" - 54" IPS DR 26
4" - 54" IPS DR 32.5
4" - 54" IPS DR 41

[2] Special sizes may be acceptable for engineered applications, due to system conditions or
    special local requirements. It is the responsibility of the
    end user to ensure the product is suitable for the intended application.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+
 
PE 4710
 
WL Plastics PA/WLP PA
 
AWWA C901
3/4" - 3" IPS SDR 9

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+
 
PE 3608/4710
 
WL Plastics PA/WLP PA Blue
 
ASTM D2239
3/4" - 2" SIDR 5.3
3/4" - 2" SIDR 7
3/4" - 2" SIDR 9
1/2" - 3" SIDR 11.5[1]

3/4" - 3" SIDR 15[1]

1/2" - 2" SIDR 19[1]

[1] These pipe sizes are not certified for use in potable water applications containing
    oxidizing disinfectants and shall not be marked with a CC oxidative resistance
    classification.						
    
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+
 
PE 4710
 
WL Plastics PA/WLP PA Blue
 
ASTM D3035
1/2" DR 7[1]

3/4" - 3" DR 7
1/2" DR 9[1]

3/4" - 3" DR 9
1/2" - 3" DR 11[1]

1/2" - 3" DR 13.5[1]

3/4" - 3" DR 15.5[1]

3/4" - 3" DR 17[1]

1" - 3" DR 21[1]

1" - 3" DR 26[1]

1 1/2" - 3" DR 32.5[1]

[1] These pipe sizes are not certified for use in potable water applications containing
    oxidizing disinfectants and shall not be marked with a CC oxidative resistance
    classification.						
    
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+
 
PE 4710
 
WL Plastics PA/WLP PA Blue
 
ASTM D2737
3/4" - 2" SDR 9

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+
 
PE 4710
 
WL Plastics PA/WLP PA Blue
 
ASTM F714
4" - 18" IPS DR 7.3
4" - 26" IPS DR 7
4" - 36" IPS DR 9
4" - 42" IPS DR 11
4" - 48" IPS DR 13.5
4" - 54" IPS DR 15.5[2]

4" - 54" IPS DR 17
4" - 54" IPS DR 21
4" - 54" IPS DR 26
4" - 54" IPS DR 32.5
4" - 54" IPS DR 41

[2] Special sizes may be acceptable for engineered applications, due to system conditions or
    special local requirements. It is the responsibility of the
    end user to ensure the product is suitable for the intended application.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe+
 
PE 4710
 
WL Plastics PA/WLP PA Blue
 
AWWA C901
3/4" - 3" IPS SDR 9

+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.

Pipe* +
 
PE 4710
 
WL Plastics PA/WLP PA
 
AWWA C906
4" - 24" IPS DR 7
4" - 24" IPS DR 7.3[2]

4" - 24" IPS DR 9
4" - 24" IPS DR 11
4" - 24" IPS DR 13.5
4" - 24" IPS DR 15.5[2]

4" - 24" IPS DR 17
4" - 24" IPS DR 21
4" - 24" IPS DR 26[2]

4" - 24" IPS DR 32.5[2]

[2] Special sizes may be acceptable for engineered applications, due to system conditions or
    special local requirements. It is the responsibility of the
    end user to ensure the product is suitable for the intended application.
* Product tested and Certified for Cold 23°C (73°F) applications only.
+ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at 73° F.



 
Zurn PEX, Inc. 
116 Maple Street
Commerce, TX 75428 
United States 
903-886-2580
Visit this company's website

Facility : Harborcreek, PA

Fire Sprinkler Pipe and Fitting Systems

Product Type   Material Type   Trade Name   Product Standard

Pipe and Fitting System% ** [G]
 
MLTPL
 
Zurn PEX Fire Protection System
 
ANSI/CAN/UL 1821

Coupling (BARB x BARB)
1" barb x 1" barb (QQC55GFX)   1" barb x 1" barb (QQPC55FX)   1 1/4" barb x 1 1/4" barb (QQC66GFX)   1 1/2" barb x 1 1/2" barb (QQC77GFX)  
2" barb x 2" barb (QQC88GFX)  

Crimp Coupling
1" Crimp PEX X 1/2" FPT (QQFSC53GFX)  

Crimp Tee
1" Crimp PEX x 1" Crimp PEX x 1/2" FPT (QQFST553GFX)  

Elbow (BARB X BARB)
1" barb x 1" barb (QQPE55FX)   1" barb x 1" barb (QQE55GFX)   1 1/4" barb x 1 1/4" barb (QQE66GFX)   1 1/2" barb x 1 1/2" barb (QQE77GFX)  
2" barb x 2" barb (QQE88GFX)  

Expansion Coupling
1" EXP PEX x 1/2" FPT (QEFSC53GFX)  

Expansion Tee
1" EXP PEX x 1" EXP PEX x 1/2" FPT (QEFST553FGX)  

Female Adapter (BARB x FPT)
1" barb x 1" FPT (QQUFC55GFX)   1 1/4" barb x 1 1/4" FPT (QQUFC66GFX)   1 1/2" barb x 1 1/2" FPT (QQUFC77GFX)  

Female Sweat Adapter (BARB x SWEAT)
1" barb x 1" sweat (QQ800CFX)   1 1/4" barb x 1 1/4" sweat (QQ812GFX)   1 1/2" barb x 1 1/2" sweat (QQ950GFX)   2" barb x 2" sweat (QQ1050GFX)  

Fire Sprinkler Coupling
1" barb x 1/2" FPT (QQFSC53GFX)  

Fire Sprinkler Tee (BARB X BARB X FPT)
1" barb x 1" barb x 1/2" FPT (QQFST553GFX)  

Male Adapter (BARB X MPT)
1" barb x 1" MPT (QQMC55GFX)   1" barb x 1" barb MPT (QQPMC55FX)   1 1/4" barb x 1 1/4" MPT (QQMC66GFX)   1 1/2" barb x 1 1/2" MPT (QQMC77GFX)  
2" barb x 2" MPT (QQMC88GFX)  

Male Sweat Adapter (BARB X SWEAT)
1" barb x 1" sweat (QQ700CFX)  

Plug (Barb)
1" (QQP5GFX)   1 1/4" (QQP6GFX)   1 1/2" (QQP7GFX)   2" (QQP8GFX)  

Reducer Tee (BARB X BARB X BARB)
1" barb x 1" barb x 1/2" barb (QQT553GFX)   1" barb x 1" barb x 3/4" barb (QQT554GFX)   1" barb x 1" barb x 1/2" barb (QQPT553FX)   1" barb x 1" barb x 3/4" barb (QQPT554FX)  
1 1/4" barb x 1 1/4" barb x 1/2" barb (QQT663GFX)   1 1/4" barb x 1 1/4" barb x 3/4" barb (QQT664GFX)   1 1/2" barb x 1 1/2" barb x 3/4" barb (QQT774GFX)   1 1/2" barb x 1 1/2" barb x 1" barb (QQT775GFX)  
2" barb x 2" barb x 1" barb (QQT885GFX)  

Reducing Coupling (BARB x BARB)
1" barb x 3/4" barb (QQPC54FX)   1 1/4" barb x 1" barb (QQC65GFX)   1 1/2" barb x 1 1/4" barb (QQC76GFX)   2" barb x 1 1/2" barb (QQC87GFX)  

Tee (BARB X BARB X BARB)
1" barb x 1" barb x 1" barb (QQT555GFX)   1" barb x 1" barb x 1" barb (QQPT555GFX)   1 1/4" barb x 1 1/4" barb x 1 1/4" barb (QQT666GFX)   1 1/2" barb x 1 1/2" barb x 1 1/2" barb (QQT777GFX)  
2" barb x 2" barb x 2" barb (QQT888GFX)  

Tubing
1" – 2" White ZurnPEX  

% PEX pipe and fittings are intended for use in multi-purpose piping systems of
  residential occupancies as defined in ANSI/NFPA 13D, "Installation of Sprinkler Systems
  in One- and Two- Family Dwellings and Manufactured Homes" and the International
  Residential Code, Section 2904, and are designed to withstand a working pressure of not
  less than 130 psi at 120° F.  PEX pipe and fittings are intended to be installed in
  accordance with the requirements specified in the manufacturer’s installation
  instructions and ANSI/NFPA 13D. Protection is intended to be provided for PEX pipe and
  fittings in multi-purpose piping systems.  The minimum protection should consist of
  either (1) one layer of 3/8-in. gypsum wallboard, (2) a suspended membrane ceiling with
  lay-in panels or tiles having a weight of not less than 0.35 lbs per sq ft when
  installed with metallic support grids, (3) 1/2 in plywood or (4) other material with a
  15 minute fire rating. PEX pipe and fittings are intended for use in areas where the
  maximum ambient temperature does not exceed 120° F. These pipe and fittings are not
  intended to be installed in outdoor applications. The PEX pipe and fittings are intended
  for use in wet-pipe systems only and have not been evaluated for use in dry-pipe systems.
** Pipe and fittings Certified as a system using Installation/assembly instructions titled
   "Zurn PEX Residential Fire Protection Addendum to Plumbing Installation Guide".
   
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Potable Water - Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
ACCUTEK PEX - Blue, Red, White
 
ASTM F876/F877
1/8" - 2" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
ACCUTEK PEX - Blue, Red, White
 
AWWA C904
1/2" - 2" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# ^ ¢ § +++ [G]
 
PEX
 
ACCUTEK PEX - Blue, Red, White
 
CSA B137.5
1/8" - 2" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1807,
  ASTM F2159, ASTM F1960, and ASTM F2098.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
CAST Fast-Fit - Blue, Red, White
 
ASTM F876/F877
1/8" - 2" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
CAST Fast-Fit - Blue, Red, White
 
AWWA C904
1/2" - 2" SDR 9

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# ^ ¢ § +++ [G]
 
PEX
 
CAST Fast-Fit - Blue, Red, White
 
CSA B137.5
1/8" - 2" SDR 9

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1807,
  ASTM F2159, ASTM F1960, and ASTM F2098.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
PPSU
 
CR Manifold
 
ASTM F877/F2159

1" Inlet X 1" Outlet X 1/2" Outlet
3-Port [QPM553-3]   4-Port [QPM553-4]   5-Port [QPM553-5]  

1" Inlet X 1/2" Outlet
3-Port [QPM53-3]   5-Port [QPM53-5]   4-Port [QPM53-4]  

3/4" Inlet X 3/4" Outlet X 1/2" Outlet
2-Port [QPM443-2]   3-Port [QPM443-3]   4-Port [QPM443-4]  

3/4" Inlet x 1/2" Outlet
3-Port [QPM43-3]   4-Port [QPM43-4]   5-Port [QPM43-5]  

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
PPSU
 
CR Manifold
 
CSA B137.5

1" Inlet X 1/2" Outlet
3-Port [QPM53-3]   4-Port [QPM53-4]   5-Port [QPM53-5]  

1" Inlet x 1" Outlet X 1/2" Outlet
3-Port [QPM553-3]   4-Port [QPM553-4]   5-Port [QPM553-5]  

3/4" Inlet X 3/4" Outlet X 1/2" Outlet
2-Port [QPM443-2]   3-Port [QPM443-3]   4-Port [QPM443-4]  

3/4" Inlet x 1/2" Outlet
3-Port [QPM43-3]   4-Port [QPM43-4]   5-Port [QPM43-5]  

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Misc. Proc. Devices/Comp.& * +++ [G]
 
MLTPL
 
Q
 
ASTM F877
1/2" Barb x 1/2" Swivel Qickport Manifold Valve

& Certified as a component of a manifold with a maximum of 21 valves per liter for hot
  applications and a maximum of 27 valves per liter for cold applications.
* The letter Q is acceptable to be used on fittings due to size constraints.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Misc. Proc. Devices/Comp.& * +++ [G]
 
MLTPL
 
Q
 
ASTM F2159
1/2" Barb x 1/2" Swivel Qickport Manifold Valve

& Certified as a component of a manifold with a maximum of 21 valves per liter for hot
  applications and a maximum of 27 valves per liter for cold applications.
* The letter Q is acceptable to be used on fittings due to size constraints.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Misc. Proc. Devices/Comp.& * +++ [G]
 
MLTPL
 
Q
 
CSA B137.5
1/2" Barb x 1/2" Swivel Qickport Manifold Valve

& Certified as a component of a manifold with a maximum of 21 valves per liter for hot
  applications and a maximum of 27 valves per liter for cold applications.
* The letter Q is acceptable to be used on fittings due to size constraints.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
QEST®PEX - Blue, Red, White
 
ASTM F876/F877
1/8" - 2"

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
QEST®PEX - Blue, Red, White
 
AWWA C904
1/2" - 2"

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# ^ ¢ § +++ [G]
 
PEX
 
QEST®PEX - Blue, Red, White
 
CSA B137.5
1/8" - 2"

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1807,
  ASTM F2159, ASTM F1960, and ASTM F2098.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Fittings¢ § +++ [G]
 
PPSU
 
QickSert CR*
 
ASTM F2159
3/8" - 1"

Coupling
1/2" x 1/2" (QQPC33X)   3/4" x 1/2" (QQPC43X)   3/4" x 3/4" (QQPC44FX)   1" x 3/4" (QQPC55FX)  
1" x 1" (QQPC55FX)  

Elbow
1/2" x 1/2" (QQPE33X)   3/4" x 1/2" (QQPE43X)   3/4" x 3/4" (QQPE44FX)   1" x 1" (QQPE55FX)  

Male Adapter
1/2" x 1/2" (QQPMC33X)   1/2" x 3/4" (QQPMC34X)   3/4" x 3/4" (QQPMC44FX)   1" x 1" (QQPMC55FX)  

NPT Elbow
1/2" x 1/2" (QQPE33BTX)   3/4" x 3/4" (QQPE44BTX)  

Reducer Coupling
1" x 3/4" (QQPC54FX)  

Reducer Tee
3/4" x 1/2" x 3/4" (QQPT434FX)   3/4" x 3/4" x 1/2" (QQPT443FX)   3/4" x 3/4" x 1" (QQPT445FX)   1" x 3/4" x 3/4" (QQPT544FX)  
1" x 1" x 3/4" (QQPT554FX)   1" x 1" x 1/2" (QQPT553FX)  

Street Elbow
1/2" x 3/8" (QQPE32BTX)  

Swivel Adapter
3/8" x 1/2" (QQPSFC23X)   1/2" x 1/2" (QQPSFC33X)   3/4" x 3/4" (QQPSFC44X)  

Swivel Elbow
1/2" x 1/2" (QQPE33BSX)   3/4" x 3/4" (QQPE44BSX)   3/4" x 1" (QQPSFC45X)   1" x 1" (QQPSFC55X)  

Tee
1/2" x 1/2" x 1/2" (QQPT333X)   1/2" x 1/2" x 3/4" (QQPT334X)   3/4" x 1/2" x 1/2" (QQPT433X)   3/4" x 1/2" x 3/4" (QQPT434FX)  
3/4" x 3/4" x 1/2" (QQPT443FX)   3/4" x 3/4" x 3/4" (QQPT444FX)   3/4" x 3/4" x 1" (QQPT445FX)   1" x 3/4" x 3/4" (QQPT544X)  
1" x 1" x 1/2" (QQPT553FX)   1" x 1" x 3/4" (QQPT554FX)   1" x 1" x 1" (QQPT555FX)  

* The letter Q is acceptable to be used on fittings due to size constraints.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Fittings¢ § +++ [G]
 
PPSU
 
QickSert CR*
 
ASTM F877
3/8" - 1"

Coupling
1/2" x 1/2" (QQPC33X)   3/4" x 1/2" (QQPC43X)   3/4" x 3/4" (QQPC44FX)   1" x 3/4" (QQPC55FX)  
1" x 1" (QQPC55FX)  

Elbow
1/2" x 1/2" (QQPE33X)   3/4" x 1/2" (QQPE43X)   3/4" x 3/4" (QQPE44FX)   1" x 1" (QQPE55FX)  

Male Adapter
1/2" x 1/2" (QQPMC33X)   1/2" x 3/4" (QQPMC34X)   3/4" x 3/4" (QQPMC44FX)   1" x 1" (QQPMC55FX)  

NPT Elbow
1/2" x 1/2" (QQPE33BTX)   3/4" x 3/4" (QQPE44BTX)  

Reducer Coupling
1" x 3/4" (QQPC54FX)  

Reducer Tee
3/4" x 1/2" x 3/4" (QQPT434FX)   3/4" x 3/4" x 1/2" (QQPT443FX)   3/4" x 3/4" x 1" (QQPT445FX)   1" x 3/4" x 3/4" (QQPT544FX)  
1" x 1" x 1/2" (QQPT553FX)   1" x 1" x 3/4" (QQPT554FX)  

Street Elbow
1/2" x 3/8" (QQPE32BTX)  

Swivel Adapter
3/8" x 1/2" (QQPSFC23X)   1/2" x 1/2" (QQPSFC33X)   3/4" x 3/4" (QQPSFC44X)   3/4" x 1" (QQPSFC45X)  
1" x 1" (QQPSFC55X)  

Swivel Elbow
1/2" x 1/2" (QQPE33BSX)   3/4" x 3/4" (QQPE44BSX)  

Tee
1/2" x 1/2" x 1/2" (QQPT333X)   1/2" x 1/2" x 3/4" (QQPT334X)   3/4" x 1/2" x 1/2" (QQPT433X)   3/4" x 1/2" x 3/4" (QQPT434FX)  
3/4" x 3/4" x 1" (QQPT445FX)   3/4" x 3/4" x 3/4" (QQPT444FX)   1" x 3/4" x 3/4" (QQPT544X)   1" x 1" x 1/2" (QQPT553FX)  
1" x 1" x 3/4" (QQPT554FX)   1" x 1" x 1" (QQPT555FX)  

* The letter Q is acceptable to be used on fittings due to size constraints.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Fittings¢ § +++ [G]
 
PPSU
 
QickSert CR*
 
CSA B137.5
3/8" - 1"

Coupling
1/2" x 1/2" (QQPC33X)   3/4" x 1/2" (QQPC43X)   3/4" x 3/4" (QQPC44FX)   1" x 3/4" (QQPC55FX)  
1" x 1" (QQPC55FX)  

Elbow
3/4" x 1/2" (QQPE43X)   3/4" x 3/4" (QQPE44FX)   1" x 1" (QQPE55FX)  

Male Adapter
1/2" x 1/2" (QQPMC33X)   1/2" x 3/4" (QQPMC34X)   3/4" x 3/4" (QQPMC44FX)   1" x 1" (QQPMC55FX)  

NPT Elbow
1/2" x 1/2" (QQPE33BTX)   3/4" x 3/4" (QQPE44BTX)  

Reducer Coupling
1" x 3/4" (QQPC54FX)  

Reducer Tee
3/4" x 1/2" x 3/4" (QQPT434FX)   3/4" x 3/4" x 1/2" (QQPT443FX)   3/4" x 3/4" x 1" (QQPT445FX)   1" x 3/4" x 3/4" (QQPT544FX)  
1" x 1" x 1/2" (QQPT553FX)   1" x 1" x 3/4" (QQPT554FX)  

Street Elbow
1/2" x 3/8" (QQPE32BTX)  

Swivel Adapter
3/8" x 1/2" (QQPSFC23X)   1/2" x 1/2" (QQPSFC33X)   3/4" x 3/4" (QQPSFC44X)   3/4" x 1" (QQPSFC45X)  
1" x 1" (QQPSFC55X)  

Swivel Elbow
1/2" x 1/2" (QQPE33BSX)   3/4" x 3/4" (QQPE44BSX)  

Tee
1/2" x 1/2" x 1/2" (QQPT333X)   1/2" x 1/2" x 3/4" (QQPT334X)   3/4" x 1/2" x 1/2" (QQPT433X)   3/4" x 1/2" x 3/4" (QQPT434FX)  
3/4" x 3/4" x 1/2" (QQPT443FX)   3/4" x 3/4" x 3/4" (QQPT444FX)   3/4" x 3/4" x 1" (QQPT445FX)   1" x 3/4" x 3/4" (QQPT544X)  
1" x 1" x 1/2" (QQPT553FX)   1" x 1" x 3/4" (QQPT554FX)   1" x 1" x 1" (QQPT555FX)  

* The letter Q is acceptable to be used on fittings due to size constraints.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Misc. Proc. Devices/Comp.& * +++ [G]
 
MLTPL
 
Qicksert QPBV2X
 
ASTM F877
1/2" Barb x 1/2" Swivel Qickport Manifold Valve

& Certified as a component of a manifold with a maximum of 21 valves per liter for hot
  applications and a maximum of 27 valves per liter for cold applications.
* The letter Q is acceptable to be used on fittings due to size constraints.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Misc. Proc. Devices/Comp.& * +++ [G]
 
MLTPL
 
Qicksert QPBV2X
 
ASTM F2159
1/2" Barb x 1/2" Swivel Qickport Manifold Valve

& Certified as a component of a manifold with a maximum of 21 valves per liter for hot
  applications and a maximum of 27 valves per liter for cold applications.
* The letter Q is acceptable to be used on fittings due to size constraints.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Misc. Proc. Devices/Comp.& * +++ [G]
 
MLTPL
 
Qicksert QPBV2X
 
CSA B137.5
1/2" Barb x 1/2" Swivel Qickport Manifold Valve

& Certified as a component of a manifold with a maximum of 21 valves per liter for hot
  applications and a maximum of 27 valves per liter for cold applications.
* The letter Q is acceptable to be used on fittings due to size constraints.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Misc. Proc. Devices/Comp.& * ++ [G]
 
MLTPL
 
Qicksert QPBV3X
 
ASTM F877
1/2" Barb x 1/2" Swivel QickPort Manifold Valve

& Certified as a component of a manifold with a maximum of 21 valves per liter for hot
  applications and a maximum of 27 valves per liter for cold applications.
* The letter Q is acceptable to be used on fittings due to size constraints.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Misc. Proc. Devices/Comp.& * +++ [G]
 
MLTPL
 
Qicksert QPBV3X
 
ASTM F877
1/2" Barb x 1/2" Swivel Qickport Manifold Valve

& Certified as a component of a manifold with a maximum of 21 valves per liter for hot
  applications and a maximum of 27 valves per liter for cold applications.
* The letter Q is acceptable to be used on fittings due to size constraints.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Misc. Proc. Devices/Comp.& * +++ [G]
 
MLTPL
 
Qicksert QPBV3X
 
ASTM F2159
1/2" Barb x 1/2" Swivel Qickport Manifold Valve

& Certified as a component of a manifold with a maximum of 21 valves per liter for hot
  applications and a maximum of 27 valves per liter for cold applications.
* The letter Q is acceptable to be used on fittings due to size constraints.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Misc. Proc. Devices/Comp.& * +++ [G]
 
MLTPL
 
Qicksert QPBV3X
 
CSA B137.5
1/2" Barb x 1/2" Swivel Qickport Manifold Valve

& Certified as a component of a manifold with a maximum of 21 valves per liter for hot
  applications and a maximum of 27 valves per liter for cold applications.
* The letter Q is acceptable to be used on fittings due to size constraints.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QKIPSP
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QKIPSP
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM10
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM10
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM20
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM20
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM3H9C
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM3H9C
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM3H9C-3
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM3H9C-3
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM6H12C
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM6H12C
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM6H12C-3
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM6H12C-3
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM9H15C
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM9H15C
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM9H15C-3
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM9H15C-3
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM10-3
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM10-3
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM20-3
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM20-3
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM12H18C
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM12H18C
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM18H18C6NS
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM18H18C6NS
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM15H21C
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM15H21C
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM18H24C
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM18H24C
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM18H24C-3
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM18H24C-3
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM9H9C6NS
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM9H9C6NS
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM9H9C6NS-3
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM9H9C6NS-3
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM12H12C6NS
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM12H12C6NS
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM12H12C6NS-3
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM12H12C6NS-3
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM15H15C6NS
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM15H15C6NS
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM15H15C6NS-3
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM15H15C6NS-3
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM15H21C-3
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM15H21C-3
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM12H18C-3
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM12H18C-3
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM18H18C6NS-3
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM18H18C6NS-3
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM21H21C6NS
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ +++ [G]
 
MLTPL
 
QPPM21H21C6NS
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM21H21C6NS-3
 
ASTM F877
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Manifolds¢ § +++ [G]
 
MLTPL
 
QPPM21H21C6NS-3
 
CSA B137.5
1" MPT x 1/2" MPT

¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
WarmPex - Red
 
ASTM F876/F877
1/8" - 2"

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
WarmPex - Red
 
AWWA C904
1/2" - 2"

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# ^ ¢ § +++ [G]
 
PEX
 
WarmPex - Red
 
CSA B137.5
1/8" - 2"

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1807,
  ASTM F2159, ASTM F1960, and ASTM F2098.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
ZURNPEX - Blue, Red, White
 
ASTM F876/F877
1/8" - 2"

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing^ ¢ § +++ [G]
 
PEX 5306
 
ZURNPEX - Blue, Red, White
 
AWWA C904
1/2" - 2"

^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Tubing# ^ ¢ § +++ [G]
 
PEX
 
ZURNPEX - Blue, Red, White
 
CSA B137.5
1/8" - 2"

# Tubing certified against CSA B137.5 shall include the standard designation(s) of the
  fitting system(s) for which the tubing is recommended by the manufacturer, and shall be
  marked, as applicable, with the following fitting system designation(s): ASTM F1807,
  ASTM F2159, ASTM F1960, and ASTM F2098.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM 2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


Radiant Floor Heating

Product Type   Material Type   Trade Name   Product Standard

Tubing#
 
PEX 0006
 
ACCUTEK PEX - Blue, Natural, Red, White
 
SE 8221
3/8" - 1"

# Pipe Certified as a system using QEST®PEX fittings manufactured by ZurnPex Inc. 
  Installation/assembly instructions titled "QEST®PEX Professional PEX Plumbing System
  Installation Guide", dated September 1995.

Tubing#
 
PEX 0006
 
QEST®PEX Hydronic Barrier-Blue, Red, Natural
 
SE 8221
3/8" - 1"

# Pipe Certified as a system using QEST®PEX fittings manufactured by ZurnPex Inc. 
  Installation/assembly instructions titled "QEST®PEX Professional PEX Plumbing System
  Installation Guide", dated September 1995.

Tubing#
 
PEX 0006
 
Slant/Fin Terra Therma
 
SE 8221
3/8" - 1"

# Pipe Certified as a system using QEST®PEX fittings manufactured by ZurnPex Inc. 
  Installation/assembly instructions titled "QEST®PEX Professional PEX Plumbing System
  Installation Guide", dated September 1995.

Tubing#
 
PEX 0006
 
WarmPex - Red
 
SE 8221
3/8" - 1"

# Pipe Certified as a system using QEST®PEX fittings manufactured by ZurnPex Inc. 
  Installation/assembly instructions titled "QEST®PEX Professional PEX Plumbing System
  Installation Guide", dated September 1995.

Tubing#
 
PEX 0006
 
ZURNPEX Hydronic Barrier - Blue, Red, Natural
 
SE 8221
3/8" - 1"

# Pipe Certified as a system using QEST®PEX fittings manufactured by ZurnPex Inc. 
  Installation/assembly instructions titled "QEST®PEX Professional PEX Plumbing System
  Installation Guide", dated September 1995.

Tubing#
 
PEX 0006
 
Zurn PEX Performa
 
SE 8221
3/8" - 1"

# Pipe Certified as a system using QEST®PEX fittings manufactured by ZurnPex Inc. 
  Installation/assembly instructions titled "QEST®PEX Professional PEX Plumbing System
  Installation Guide", dated September 1995.


NSF/ANSI 24
Plumbing System Components for Recreational Vehicles



 
Shell Chemical Appalachia LLC 
P.O. Box 4749
Houston, TX 77210-4749 
United States 
724-709-2268

Facility : Monaca, PA

Potable Water Materials for Recreational Vehicles
35R5U - Medium-Density Polyethylene Resin* ++   35R5U.DEV - Medium-Density Polyethylene Resin* ++   35R7U - Medium-Density Polyethylene Resin* ++   39R4U - Medium-Density Polyethylene Resin* ++  
39R4U.DEV Medium-Density Polyethylene Resin* ++  

Tank Materials for Recreational Vehicles
35R5U - Medium-Density Polyethylene Resin** ++   35R5U.DEV - Medium-Density Polyethylene Resin** ++   35R7U - Medium-Density Polyethylene Resin** ++   39R4U - Medium-Density Polyethylene Resin** ++  
39R4U.DEV Medium-Density Polyethylene Resin* ++  

* Certified for pipe, fitting and appurtenance end use.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).
* Certified for pipe, fitting and appurtenance end use.
** Certified for use in Tanks = 5 gal.
++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
   temperatures up to and including Domestic Hot (140° F).


MP
Mechanical Plumbing Products



 
Charlotte Pipe & Foundry Company 
Plastics Division
4210 Old Charlotte Highway 
P.O. Box 1339 
Monroe, NC 28111-1339 
United States 
704-291-3218
Visit this company's website

Facility : Muncy, PA

Product Type   Material Type   Trade Name   Product Standard

Pipe
 
MLTPL
 
Charlotte Pipe®
 
CSA Z240.3.2

Pipe§
 
PVC
 
Charlotte Pipe®
 
CSA Z240.3.2
1 1/4" - 6" DR 24

§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.



 
Victaulic 
4901 Kesslersville Road
Easton, PA 18040 
United States 
800-742-5842 
610-559-3300
Visit this company's website

Facility : Easton, PA

Product Type   Material Type   Trade Name   Product Standard

Couplings[1]
 
Ductile Iron
 
Victaulic
 
ASTM F1476

Flexible Couplings
Style 77 (1" - 10")  

Rigid Couplings
Style 07 (1" - 12")   Style 107H (2" - 8")   Style 607 (2" - 6")   Style 89 (2" - 12")  

[1] Products rated to 300 psi.

Fittings[1]
 
Bronze
 
Victaulic
 
ASTM F1548

Endcaps
No. 660 (2" - 6")  

[1] Products rated to 300 psi.

Fittings[1]
 
Copper
 
Victaulic
 
ASTM F1548

Reducing Tee
No. 625 (3" x 2" - 4" x 3")  

Tee
No. 620 (2" - 6")  

[1] Products rated to 300 psi.

Fittings[1]
 
Ductile Iron
 
Victaulic
 
ASTM F1548

11 1/4° Elbow
No. 13 (2 1/2")  

45° Elbow
No. 11 (1 1/2" - 12")  

90° Elbow
No. 10 (1 1/2" - 12")  

90° w/Drain Elbow
No. 10DR (3" - 6")  

Copper Elbow
No. 610 (2 1/2")  

Dielectric Waterway
Style 47 (1" - 8")  

End Cap
No. 60 (1" - 12")  

Flange Adapter
Style 641 (2" - 6")   Style 741 (2 1/2" - 12")  

Reducer
No. 50 (2" x 1 1/2" - 10" x 8")  

Reducer Tee
No. 25 (10" x 8" - 12" x 10")   No. 25 (2 1/2" x 1" - 10" x 6")  

Tee
No. 20 (2 1/2" - 10")  

[1] Products rated to 300 psi.

Fittings
 
SS
 
Victaulic
 
ASTM F1548

45º Elbow[1]
No. 411 (2" - 12")  

90º Elbow[1]
No. 410 (2" - 12")  

Concentric Reducer[1]
No. 450 (2" x 1 1/2" - 12" x 10")  

End Cap[1]
No. 460 (2" - 12")  

Reducing Tee[1]
No. 425 (2" x 1 1/2" - 12" x 10")  

Tee[2]
No. 420 (2" - 12")  

[1] Products rated to 300 psi.
[2] Products rated to 150 psi.


Facility : Easton, PA

Product Type   Material Type   Trade Name   Product Standard

Couplings[1]
 
Ductile Iron
 
Victaulic
 
ASTM F1476

Flexible Couplings
Style 77 (1" - 10")  

Rigid Couplings
Style 07 (1" - 12")   Style 107H (2" - 8")   Style 607 (2" - 6")   Style 89 (2" - 12")  

[1] Products rated to 300 psi.

Fittings[1]
 
Bronze
 
Victaulic
 
ASTM F1548

Endcaps
No. 660 (2" - 6")  

[1] Products rated to 300 psi.

Fittings[1]
 
Copper
 
Victaulic
 
ASTM F1548

Reducing Tee
No. 625 (3" x 2" - 4" x 3")  

Tee
No. 620 (2" - 6")  

[1] Products rated to 300 psi.

Fittings[1]
 
Ductile Iron
 
Victaulic
 
ASTM F1548

11 1/4° Elbow
No. 13 (2 1/2")  

45° Elbow
No. 11 (1 1/2" - 12")  

90° Elbow
No. 10 (1 1/2" - 12")  

90° w/Drain Elbow
No. 10DR (3" - 6")  

Copper Elbow
No. 610 (2 1/2")  

Dielectric Waterway
Style 47 (1" - 8")  

End Cap
No. 60 (1" - 12")  

Flange Adapter
Style 641 (2" - 6")   Style 741 (2 1/2" - 12")  

Reducer
No. 50 (2" x 1 1/2" - 10" x 8")  

Reducer Tee
No. 25 (10" x 8" - 12" x 10")   No. 25 (2 1/2" x 1" - 10" x 6")  

Tee
No. 20 (2 1/2" - 10")  

[1] Products rated to 300 psi.

Fittings
 
SS
 
Victaulic
 
ASTM F1548

45º Elbow[1]
No. 411 (2" - 12")  

90º Elbow[1]
No. 410 (2" - 12")  

Concentric Reducer[1]
No. 450 (2" x 1 1/2" - 12" x 10")  

End Cap[1]
No. 460 (2" - 12")  

Reducing Tee[1]
No. 425 (2" x 1 1/2" - 12" x 10")  

Tee[2]
No. 420 (2" - 12")  

[1] Products rated to 300 psi.
[2] Products rated to 150 psi.



 
Zurn PEX, Inc. 
116 Maple Street
Commerce, TX 75428 
United States 
903-886-2580
Visit this company's website

Facility : Harborcreek, PA

Product Type   Material Type   Trade Name   Product Standard

Misc. Proc. Devices/Comp.& * +++ [G]
 
MLTPL
 
Q
 
ASME A112.18.1/CSA B125.1
1/2" Barb x 1/2" Swivel Qickport Manifold Valve

& Certified as a component of a manifold with a maximum of 21 valves per liter for hot
  applications and a maximum of 27 valves per liter for cold applications.
  
* The letter Q is acceptable to be used on fittings due to size constraints.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Misc. Proc. Devices/Comp.& * +++ [G]
 
MLTPL
 
Qicksert QPPBV2X
 
ASME A112.18.1/CSA B125.1
1/2" Barb x 1/2" Swivel Qickport Manifold Valve

& Certified as a component of a manifold with a maximum of 21 valves per liter for hot
  applications and a maximum of 27 valves per liter for cold applications.
  
* The letter Q is acceptable to be used on fittings due to size constraints.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    

Misc. Proc. Devices/Comp.& * +++ [G]
 
MLTPL
 
Qicksert QPPBV3X
 
ASME A112.18.1/CSA B125.1
1/2" Barb x 1/2" Swivel Qickport Manifold Valve

& Certified as a component of a manifold with a maximum of 21 valves per liter for hot
  applications and a maximum of 27 valves per liter for cold applications.
  
* The letter Q is acceptable to be used on fittings due to size constraints.
+++ Material complies with NSF/ANSI/CAN 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product is Certified to NSF/ANSI 372 and conforms with the lead content requirements for
    “lead free” plumbing as defined by California, Vermont, Maryland, and Louisiana state
    laws and the U.S. Safe Drinking Water Act.

    


NSF/ANSI 358
Water-Based Ground-Source “Geothermal” Heat Pump Systems



 
Georg Fischer Central Plastics LLC 
4949 Joseph Hardin Drive
Dallas, TX 75236 
United States 
469-801-2246

Facility : Titusville, PA

NSF/ANSI 358-1 Polyethylene Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe$ @
 
PE 4710
 
+GF+ DESIGN FLOW
 
ASTM D3035
3" DR 9, 11, 13.5, 15.5, 17
3/4" - 2" DR 9, 11

$ These products also meet the requirements for PE 3408 per ASTM D3350-02a.
@ Certified product may include a fused U-bend fitting.

Pipe$ @
 
PE 4710
 
+GF+ DESIGN FLOW
 
ASTM F714
4" - 24" DR 9, 11, 13.5, 15.5, 17

$ These products also meet the requirements for PE 3408 per ASTM D3350-02a.
@ Certified product may include a fused U-bend fitting.



 
WL Plastics Corporation 
3575 Lone Star Circle
Suite 300 
Fort Worth, TX 76177 
United States 
682-831-2727
Visit this company's website

Facility : Titusville, PA

NSF/ANSI 358-1 Polyethylene Pipe and Fittings

Product Type   Material Type   Trade Name   Product Standard

Pipe* @
 
PE 4710
 
WL Plastics PA/WLP PA Geothermal Pipe
 
ASTM D3035
1/2" DR 7[1]

3/4" - 3" DR 7
1/2" DR 9[1]

3/4" - 3" DR 9
1/2" - 3" DR 11[1]

1/2" - 3" DR 13.5[1]

3/4" - 3" DR 15.5[1]

3/4" - 3" DR 17[1]

1" - 3" DR 21[1]

1" - 3" DR 26[1]

1 1/2" - 3" DR 32.5[1]

[1] These pipe sizes are not certified for use in potable water applications containing
    oxidizing disinfectants and shall not be marked with a CC oxidative resistance
    classification.
* These products also meet the requirements for PE 3408 per ASTM D3350-02a.
@ Certified product may include a fused U-bend fitting.

Pipe* @
 
PE 4710
 
WL Plastics PA/WLP PA Geothermal Pipe
 
ASTM F714
4" - 18" IPS DR 7.3
4" - 26" IPS DR 7
4" - 36" IPS DR 9
4" - 42" IPS DR 11
4" - 48" IPS DR 13.5
4" - 54" IPS DR 15.5[2]

4" - 54" IPS DR 17
4" - 54" IPS DR 21
4" - 54" IPS DR 26
4" - 54" IPS DR 32.5
4" - 54" IPS DR 41

[2] Special sizes may be acceptable for engineered applications, due to system conditions or
    special local requirements. It is the responsibility of the end user to ensure the
    product is suitable for the intended application.
* These products also meet the requirements for PE 3408 per ASTM D3350-02a.
@ Certified product may include a fused U-bend fitting.


Fabricated Ductile Iron Pipe
NAPF QualityPlus™ Certification Program



 
National Association of Pipe Fabricators 
2313 Northeast 160th Loop
Vancouver, WA 98684 
United States 
205-706-0886
Visit this company's website

Facility : U.S. Pipe Fabrication Ephrata, PA
Product Type   Material Type   Trade Name   Product Standard

Pipe
 
Ductile Iron
 
U.S. Pipe
 
AWWA C115

Flanged Ductile Iron Pipe
3" - 64"  

Pipe
 
Ductile Iron
 
U.S. Pipe
 
AWWA C606

Grooved / Shouldered Joint Pipe
3" - 64"  

NOTE: Certification applies to grooved and/or flanged pipe only. Certification does not cover
      the design or rating of couplings or hydrostatic joint tests. Pipe may be flanged on one
      end and grooved on the other. In this case, pipe is Certified to both AWWA C115 and AWWA
      C606.
NOTE: Product is also Certified to NSF/ANSI/CAN 61 for drinking water applications.

Number of matching Manufacturers is 19
Number of matching Products is 893