NSF Product and Service Listings
These NSF Official Listings are current as of Thursday, January 15, 2026 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/Pools/Listings.asp?Company=43155&Standard=050&
NSF/ANSI 50
Equipment for Swimming Pools, Spas, Hot Tubs
and Other Recreational Water Facilities
Equipment for Swimming Pools, Spas, Hot Tubs
and Other Recreational Water Facilities
| Sta-Rite Industries, Inc. | |
| 293 Wright Street | |
| Delavan, WI 53115-2000 | |
| United States | |
| 262-728-5551 | |
| Visit this company's website |
Facility : # 1 Sanford, NC
Precoat Media-Type Filters (DE, Perlite, or Cellulose Media)
| Model Number | Filter Type | Design Filtration Rate GPM Per ft² |
Effective Filtration Area (ft²) |
End Use |
|
D.E. Filter |
||||
| PLD50 | D.E. | 2 | 30 | Pool or Spa/Hot Tub |
| PLD70 | D.E. | 1.94 | 36 | Pool or Spa/Hot Tub |
| S7D75 | D.E. | 2 | 37 | Pool or Spa/Hot Tub |
| S7MD60 | D.E. | 2 | 60 | Pool or Spa/Hot Tub |
| S7MD72 | D.E. | 2 | 72 | Pool or Spa/Hot Tub |
| S8D110 | D.E. | 2 | 53 | Pool or Spa/Hot Tub |
Sand Type Filters
| Model Number | Filter Type | Design Filtration Rate GPM Per ft² |
Effective Filtration Area (ft²) |
End Use |
|
Refer to Pressure Loss Footnote[1] |
||||
| S7S50 | High Rate Sand | 15-20 | 2.4 | Pool or Spa/Hot Tub |
| S8S70 | High Rate Sand | 15-20 | 3.4 | Pool or Spa/Hot Tub |
[1] Maximum Pressure Loss
Flow Rate Static Pressure Total Pressure
gpm/sq. ft. Loss, psig Loss, psi
5 1.2 0.9
10 2.3 1.9
15 4.4 3.9
20 7 6.5
|
||||
Pumps
|
IntelliPro Variable Speed Self-Priming Centrifugal Pump[1] [2] [3] |
||||||
| IntelliPro 2 VST / 013001 | IntelliPro VS / P6E6VS4H-209L | IntelliPro VS 013028 | ||||
| IntelliPro VS+SVRS / 013002 | IntelliPro VS+SVRS / P6E6XS4H-209L | IntelliPro VS+SVRS / S-013003 | ||||
| IntelliPro VS+SVRS / S-P6E6XS4H-209L | IntelliPro VSF / 013004 | IntelliPro XF VS / 023005 | ||||
| IntelliPro XF VS / 023055 | IntelliPro XF VS+SVRS / 023057 | IntelliPro XF VSF / 023056 | ||||
[1] Listed for use with pools, spas, and hot tubs. [2] Self-priming at 10' [3] NSF Certification does not include testing to ASME A112.19.17. |
||||||
|
Sigura Booster Pump[1] |
||||||
| 79214 | ||||||
[1] Listed for use with pools, spas, and hot tubs. |
||||||
Cartridge and High Permeability Type Filters
| Model Number | Filter Type | Design Filtration Rate GPM Per ft² |
Effective Filtration Area (ft²) |
End Use |
|
Modular Media Cartridge Filter |
||||
| PLM100 | Cartridge | .375-[2] | 100 | Pool or Spa/Hot Tub |
| PLM100 | Cartridge | .75-[1] | 100 | Pool or Spa/Hot Tub |
| PLM125 | Cartridge | .375-[2] | 125 | Pool or Spa/Hot Tub |
| PLM125 | Cartridge | .75-[1] | 125 | Pool or Spa/Hot Tub |
| PLM150 | Cartridge | .375-[2] | 150 | Pool or Spa/Hot Tub |
| PLM150 | Cartridge | .75-[1] | 150 | Pool or Spa/Hot Tub |
| PLM175 | Cartridge | .375-[2] | 175 | Pool or Spa/Hot Tub |
| PLM175 | Cartridge | .75-[1] | 175 | Pool or Spa/Hot Tub |
| PLM200 | Cartridge | .375-[2] | 200 | Pool or Spa/Hot Tub |
| PLM200 | Cartridge | .75-[1] | 200 | Pool or Spa/Hot Tub |
| PLM300 | Cartridge | .375-[2] | 300 | Pool or Spa/Hot Tub |
| PLM320 | Cartridge | .375-[2] | 320 | Pool or Spa/Hot Tub |
[1] Residential. [2] Public. |
||||
Facility : North Aurora, IL
Pumps
|
Cast Iron Self Priming Centrifugal Pump[1] [2] |
||||||
| CCSPH2K3-142[3] | CCSPH2L3-143[3] | CCSPH2M3-144[3] | ||||
| CCSPH2N3-145[3] | CCSPHK3-142S[3] | CSPH2K3-142[3] | ||||
| CSPH2L3-143[3] | CSPH2M3-144[3] | CSPH2N3-145[3] | ||||
[1] NSF Listed units must be installed with an NSF Certified hair and lint strainer. [2] Certified for pools (75°F) and spa (104°F) end use. [3] 3-phase motor. |
||||||
Facility : Delavan, WI
Pumps
|
Cast Iron Self-Priming Centrifugal Pump[1] [2] |
||||||
| CCSPH2K3-142[3] | CCSPH2L3-143[3] | CCSPH2M3-144[3] | ||||
| CCSPH2N3-145[3] | CCSPHK3-142S[3] | CSPH2K3-142[3] | ||||
| CSPH2L3-143[3] | CSPH2M3-144[3] | CSPH2N3-145[3] | ||||
[1] Listed for use with pools, spas, and hot tubs. [2] NSF Listed units must be installed with an NSF Certified hair and lint strainer. [3] 3-phase motor. |
||||||
|
Sigura Booster Pump[1] |
||||||
| 79214 | ||||||
[1] Listed for use with pools, spas, and hot tubs. |
||||||
Materials and Components
|
Hair and Lint Strainer[1] |
||||||
| PKG-184 | PKG-184C | |||||
[1] Complies with NSF/ANSI Standard 50 Health effects for pools and spas. |
||||||
Strainers
| Trade Designation | Maximum Flow Rate (gpm) |
Head Loss (psi) |
Maximum Pressure Rating (psi) |
End Use | ||
|
Hair and Lint Strainers |
||||||
| Pkg 98 | 175 | 6 | 25 | Pool or Spa/Hot Tub | ||
| Pkg 99 | 175 | 6 | 25 | Pool or Spa/Hot Tub | ||
Facility : Cp Reynosa, Tamp., Mexico
Materials and Components
|
Vacuum Port Door Fitting[1] [2] [3] |
||||||
| GW9530 | ||||||
[1] Certified to NSF/ANSI Standard 50 for material safety. Certified for pool and spa end
use.
[2] Tested to the requirements of IAPMO 4-99a.
[3] This product has been exempted from the permanent product marking requirement, due to
size restrictions.
|
||||||
Number of matching Manufacturers is 1