NSF Product and Service Listings
These NSF Official Listings are current as of Monday, May 20, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/Pools/Listings.asp?Company=C0005366&
NSF/ANSI 50
Equipment for Swimming Pools, Spas, Hot Tubs
and Other Recreational Water Facilities
Equipment for Swimming Pools, Spas, Hot Tubs
and Other Recreational Water Facilities
Neptune-Benson, Inc. formerly known as Lawson Aquatics, Inc. | |
334 Knight Street | |
Suite 3100 | |
Warwick, RI 02886 | |
United States | |
401-821-2200 | |
Visit this company's website |
Facility : # 1 USA
Materials and Components
9" x 9" Suction Fitting[1] [2] |
||||||
MLD-FGD-0909 | MLD-SG-0909 | |||||
[1] NSF Listed units black and white. [2] Certified to ASME A112.19.8a-2008 and NSF 50. For additional information see the ASME A112.19.8a-2008 Listing. |
||||||
12" x 12" Suction Fitting[1] [2] |
||||||
MLD-FGD-1212 | MLD-SG-1212 | |||||
[1] NSF Listed units black and white. [2] Certified to ASME A112.19.8a-2008 and NSF 50. For additional information see the ASME A112.19.8a-2008 Listing. |
||||||
18" x 18" Suction Fitting[1] [2] |
||||||
MLD-FGD-1818 | MLD-SG-1818 | |||||
[1] NSF Listed units black and white. [2] Certified to ASME A112.19.8a-2008 and NSF 50. For additional information see the ASME A112.19.8a-2008 Listing. |
||||||
18" x 36" Suction Fitting[1] [2] |
||||||
FI-SG-1836 | MLD-FG-1836 | |||||
[1] NSF Listed units black and white. [2] Certified to ASME A112.19.8a-2008 and NSF 50. For additional information see the ASME A112.19.8a-2008 Listing. |
||||||
18" x 54" Suction Fitting[1] [2] |
||||||
FI-SG-1854 | MLD-FG-1854 | |||||
[1] NSF Listed units black and white. [2] Certified to ASME A112.19.8a-2008 and NSF 50. For additional information see the ASME A112.19.8a-2008 Listing. |
ANSI/APSP/ICC-16
Suction Outlet Fitting Assemblies (SOFA) for Use in Pools, Spas and Hot Tubs
Suction Outlet Fitting Assemblies (SOFA) for Use in Pools, Spas and Hot Tubs
Neptune-Benson, Inc. formerly known as Lawson Aquatics, Inc. | |
334 Knight Street | |
Suite 3100 | |
Warwick, RI 02886 | |
United States | |
401-821-2200 | |
Visit this company's website |
Facility : # 1 USA
Suction Outlet Fitting Assembly Model |
Sump Port Location |
Pipe size | Orientation (Wall and/or Floor) |
Design Flow Rate (GPM) |
||
9" x 9" Suction Fitting[1] [2] [3] |
||||||
1001-9895 (MLD-SG-0909) | Side | 4" | Floor | 237 | ||
1001-9895 (MLD-SG-0909) | Side | 4" | Wall | 199 | ||
1001-9898 (MLD-FG-0909)[4] | Side | 4" | Floor | 237 | ||
1001-9898 (MLD-FG-0909)[4] | Side | 4" | Wall | 199 | ||
[1] NSF Listed units black and white. [2] These products are certified to ANSI/APSP/ICC-16 2017. [3] Manufactured SOFA components have been evaluated and Certified to NSF/ANSI/CAN 50; field fabricated sumps have not been evaluated to health effects materials under section 4.0. [4] Suction outlet assemblies with a field-built sumps, noted with an FG, have the same sump dimensions as the manufactured sump, noted with an SG. |
||||||
12" x 12" Suction Fitting[1] [2] [3] |
||||||
1001-9893 (MLD-SG -1212) | Side | 6" | Wall | 340 | ||
1001-9893 (MLD-SG-1212) | Side | 6" | Floor | 365 | ||
1001-9896 (MLD-FG-1212)[4] | Side | 6" | Floor | 365 | ||
1001-9896 (MLD-FG-1212)[4] | Side | 6" | Wall | 340 | ||
[1] NSF Listed units black and white. [2] These products are certified to ANSI/APSP/ICC-16 2017. [3] Manufactured SOFA components have been evaluated and Certified to NSF/ANSI/CAN 50; field fabricated sumps have not been evaluated to health effects materials under section 4.0. [4] Suction outlet assemblies with a field-built sumps, noted with an FG, have the same sump dimensions as the manufactured sump, noted with an SG. |
||||||
18" x 18" Suction Fitting[1] [2] [3] |
||||||
1001-9894 (MLD-SG-1818) | Side | 8" | Floor | 816 | ||
1001-9894 (MLD-SG-1818) | Side | 8" | Wall | 696 | ||
1001-9897 (MLD-FG-1818)[4] | Side | 8" | Wall | 696 | ||
1001-9897 (MLD-FG-1818)[4] | Side | 8" | Wall | 696 | ||
[1] NSF Listed units black and white. [2] These products are certified to ANSI/APSP/ICC-16 2017. [3] Manufactured SOFA components have been evaluated and Certified to NSF/ANSI/CAN 50; field fabricated sumps have not been evaluated to health effects materials under section 4.0. [4] Suction outlet assemblies with a field-built sumps, noted with an FG, have the same sump dimensions as the manufactured sump, noted with an SG. |
||||||
18" x 36" Suction Fitting[1] [2] [5] |
||||||
1000-8099 (MLD-SG-1836) | Side | 12" | Wall | 1496 | ||
1000-8099(MLD-SG-1836) | Side | 12" | Floor | 2080 | ||
[1] NSF Listed units black and white. [2] These products are certified to ANSI/APSP/ICC-16 2017. [5] These products have been certified to NSF/ANSI/CAN 50 for water contact material health effects. |
||||||
18" x 54" Suction Fitting[1] [2] [5] |
||||||
1000-8122 (MLD-SG-1854) | Side | 14" | Floor | 3120 | ||
MLD-FG-1854 | Side | 14" | Wall | 2244 | ||
[1] NSF Listed units black and white. [2] These products are certified to ANSI/APSP/ICC-16 2017. [5] These products have been certified to NSF/ANSI/CAN 50 for water contact material health effects. |
||||||
18" x 72" Suction Fitting[1] [2] [5] |
||||||
1000-8122 (MLD-SG-1872) | Side | 16" | Floor | 4160 | ||
1000-8137 (MLD-SG-1872) | Side | 16" | Wall | 2992 | ||
[1] NSF Listed units black and white. [2] These products are certified to ANSI/APSP/ICC-16 2017. [5] These products have been certified to NSF/ANSI/CAN 50 for water contact material health effects. |
ANSI/APSP 16 (ASME/ANSI A112.19.8)
Suction Fittings for Use in Swimming Pools, Wading Pools,
Spas, Hot Tubs and Whirlpool Bathtub Appliances
Suction Fittings for Use in Swimming Pools, Wading Pools,
Spas, Hot Tubs and Whirlpool Bathtub Appliances
Neptune-Benson, Inc. formerly known as Lawson Aquatics, Inc. | |
334 Knight Street | |
Suite 3100 | |
Warwick, RI 02886 | |
United States | |
401-821-2200 | |
Visit this company's website |
Facility : # 1 USA
Suction Fitting Model | Sump Model or Field Type | Orientation (Wall and/or Floor) | Design Flow Rate (GPM) | |||
9" x 9"[1] [2] [3] |
||||||
MLD-FGD-0909[4] | Field Fabricated - Figure 2 | Floor | 261 | |||
MLD-FGD-0909[4] | Field Fabricated - Figure 2 | Wall | 248 | |||
MLD-SG-0909 | Super Sump™ | Wall | 248 | |||
MLD-SG-0909 | Super Sump™ | Floor | 261 | |||
[1] Certified to ASME A112.19.8a-2008. [2] NSF Listed units black and white. [3] Suction cover and grate Certified to NSF 50. [4] Only the drain cover has been Certified by NSF International to ANSI/APSP 16 (ASME A112.19.-2008). The flow rating for the drain cover is approved for use over a field fabricated main drain sump that meets the requirements of Figure 2 and the stipulations of Mandatory Appendix II of ANSI/APSP 16 (ASME A112.19.-2008). |
||||||
12" x 12"[1] [2] [3] |
||||||
MLD-FGD-1212[4] | Field Fabricated - Figure 2 | Floor | 365 | |||
MLD-FGD-1212[4] | Field Fabricated - Figure 2 | Wall | 365 | |||
MLD-SG-1212 | Super Sump™ | Floor | 400 | |||
MLD-SG-1212 | Super Sump™ | Wall | 340 | |||
[1] Certified to ASME A112.19.8a-2008. [2] NSF Listed units black and white. [3] Suction cover and grate Certified to NSF 50. [4] Only the drain cover has been Certified by NSF International to ANSI/APSP 16 (ASME A112.19.-2008). The flow rating for the drain cover is approved for use over a field fabricated main drain sump that meets the requirements of Figure 2 and the stipulations of Mandatory Appendix II of ANSI/APSP 16 (ASME A112.19.-2008). |
||||||
18" x 18"[1] [2] [3] |
||||||
MLD-FGD-1818[4] | Field Fabricated - Figure 2 | Wall | 712 | |||
MLD-FGD-1818[4] | Field Fabricated - Figure 2 | Floor | 816 | |||
MLD-SG-1818 | Super Sump™ | Wall | 712 | |||
MLD-SG-1818 | Super Sump™ | Floor | 816 | |||
[1] Certified to ASME A112.19.8a-2008. [2] NSF Listed units black and white. [3] Suction cover and grate Certified to NSF 50. [4] Only the drain cover has been Certified by NSF International to ANSI/APSP 16 (ASME A112.19.-2008). The flow rating for the drain cover is approved for use over a field fabricated main drain sump that meets the requirements of Figure 2 and the stipulations of Mandatory Appendix II of ANSI/APSP 16 (ASME A112.19.-2008). |
||||||
18" x 36"[1] [2] [3] |
||||||
FI-SG-1836[5] | Field Fabricated - Figure 2 | Floor | 2401 | |||
FI-SG-1836[4] [5] | FI-SG-1836 | Wall | 1496 | |||
FI-SG-1836[4] [5] | FI-SG-1836 | Floor | 2080 | |||
MLD-FG-1836 | Field Fabricated - Figure 2 | Floor | 2401 | |||
[1] Certified to ASME A112.19.8a-2008. [2] NSF Listed units black and white. [3] Suction cover and grate Certified to NSF 50. [4] Only the drain cover has been Certified by NSF International to ANSI/APSP 16 (ASME A112.19.-2008). The flow rating for the drain cover is approved for use over a field fabricated main drain sump that meets the requirements of Figure 2 and the stipulations of Mandatory Appendix II of ANSI/APSP 16 (ASME A112.19.-2008). [5] Prefabricated fiberglass sump with 10" connection. |
||||||
18" x 54"[1] [2] [3] |
||||||
FI-SG-1854[5] | Field Fabricated - Figure 2 | Floor | 4269 | |||
MLD-FG-1854 | Field Fabricated - Figure 2 | Floor | 4269 | |||
[1] Certified to ASME A112.19.8a-2008. [2] NSF Listed units black and white. [3] Suction cover and grate Certified to NSF 50. [5] Prefabricated fiberglass sump with 10" connection. |
||||||
18" x 72"[1] [2] [3] |
||||||
FI-SG-1872[5] | Field Fabricated - Figure 2 | Floor | 4518 | |||
MLD-FG-1872 | Field Fabricated - Figure 2 | Floor | 4518 | |||
[1] Certified to ASME A112.19.8a-2008. [2] NSF Listed units black and white. [3] Suction cover and grate Certified to NSF 50. [5] Prefabricated fiberglass sump with 10" connection. |
NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and A112.19.8b-2009 which have been withdrawn.
Number of matching Manufacturers is 3
Number of matching Products is 48
Processing time was 0 seconds