NSF Product and Service Listings

These NSF Official Listings are current as of Tuesday, December 11, 2018 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/Pools/Listings.asp?Company=C0208608&Standard=050&


NSF/ANSI 50
Equipment for Swimming Pools, Spas, Hot Tubs
and Other Recreational Water Facilities



 
ATG UV Technology 
Genesis House, Richmond Hill
Pemberton Business Centre 
Wigan WN58AA 
United Kingdom 
44 1942216161
Visit this company's website

Facility : Wigan, United Kingdom

Ultraviolet Light Process Equipment
Trade Designation Maximum
Flow Rate
(gpm)
Disinfection End Use

UV Generators[1] [2]
ECF-115-6 286 Supplemental Pool or Spa/Hot Tub
ECF-210-4[3] 300 Supplemental and Secondary Pool or Spa/Hot Tub
ECF-215-6[3] 580 Supplemental and Secondary Pool or Spa/Hot Tub
ECF-220-8[3] 930 Supplemental and Secondary Pool or Spa/Hot Tub
ECF-225-10[3] 1230 Supplemental and Secondary Pool or Spa/Hot Tub
ECF-230-12[3] 1680 Supplemental and Secondary Pool
ECF-425-10 2525 Supplemental Pool or Spa/Hot Tub
ECF-430-12[3] 3350 Supplemental and Secondary Pool or Spa/Hot Tub
ECP-110-4 114 Supplemental Pool or Spa/Hot Tub
ECP-113-5[3] 176 Supplemental and Secondary Pool or Spa/Hot Tub
SP-25-4S 210 Supplemental Pool or Spa/Hot Tub
SP-25-6 365 Supplemental Pool or Spa/Hot Tub

[1] This product has not been Certified by NSF to the requirements of the National
    Electrical Code or electrical product safety standards.
[2] Product has met the requirements of NSF/ANSI 50, Annex H.1: Disinfection Efficacy for
    the >= 3 log reduction of Enterococcus faecium [ATCC #6569] and Pseudomonas aeruginosa
    [ATCC #27313].  This product is intended for supplemental disinfection and should be
    used with registered or approved disinfection chemicals to impart residual
    concentrations in accordance with state and local regulations.  This product has not
    been evaluated to the cryptosporidium inactivation requirements of NSF/ANSI 50.	
[3] This product has been tested to confirm a minimum inactivation equivalent of 3 log
    (99.9%) cryptosporidium parvum in accordance with NSF 50 and the US EPA UV DGM. Consult
    the manufacturer's Installation and Operating Instructions for the performance operating
    parameters.  This product has met the requirements of NSF/ANSI 50, Annex
    H.1:Disinfection Efficacy for the >= minimum of a 3 log (99.9%) reduction of
    Enterococcus faecium [ATCC #6569] and Pseudomonas aeruginosa [ATCC #27313].  This
    product is intended for secondary disinfection and should be used with registered or
    approved disinfection chemicals to impart residual concentrations in accordance with
    state and local regulations.	



Number of matching Manufacturers is 1
Number of matching Products is 12
Processing time was 0 seconds