NSF/ANSI/CAN 60
Drinking Water Treatment Chemicals - Health Effects
Drinking Water Treatment Chemicals - Health Effects
| ACURO ORGANICS LIMITED | |
| DSM 446-447 | |
| DLF Tower | |
| Najafgarh Road | |
| New Dehli, 110015 | |
| India | |
| 91 11 47479797 | |
| Visit this company's website |
Facility : Noida, Uttar Pradesh, India
|
Hydrogen Peroxide[HP] |
||
| Trade Designation | Product Function | Max Use |
| ACUROSIL AQUA+ | Disinfection & Oxidation | 16mg/L |
| ACUROSIL NANO+ | Disinfection & Oxidation | 16mg/L |
| ACUROSIL T60 | Disinfection & Oxidation | 16mg/L |
| DEFENCE | Disinfection & Oxidation | 16mg/L |
| Hydrogen Peroxide 35% | Disinfection & Oxidation | 16mg/L |
| Hydrogen Peroxide 50% | Disinfection & Oxidation | 16mg/L |
| OXIWIN | Disinfection & Oxidation | 16mg/L |
| SILVOCID | Disinfection & Oxidation | 16mg/L |
| TEASAFE+ | Disinfection & Oxidation | 16mg/L |
[HP] Use of this product shall be followed by chlorination to remove levels of hydrogen
peroxide. Chlorine residuals shall not exceed 4 mg/L, the EPA's proposed maximum
residual level.
|
||
|
Miscellaneous Chemical Products |
||
| Trade Designation | Product Function | Max Use |
| ACUROX SP5 | Disinfection & Oxidation | 25mg/L |
| OXYBIO | Disinfection & Oxidation | 25mg/L |
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| ACUROCLEAN D40 | Reverse Osmosis Antiscalant | 5mg/L |
| ACUTHERM P102 | Membrane Cleaner pH Adjustment |
250mg/L |
| ALKIRO S40 | Membrane Cleaner pH Adjustment |
250mg/L |
| CAUSTIC SODA | Membrane Cleaner pH Adjustment |
250mg/L |
| CHEMIRO 909N | Reverse Osmosis Antiscalant | 8mg/L |
| NCTREAT 72 | Reverse Osmosis Antiscalant | 20mg/L |
| RADIX 31 | Reverse Osmosis Antiscalant | 8mg/L |
| RADIX 95 | Reverse Osmosis Antiscalant | 8mg/L |
| RADIX 98 | Reverse Osmosis Antiscalant | 20mg/L |
| RADIX AS333 | Reverse Osmosis Antiscalant | 5mg/L |
| RADIX P25 | Membrane Cleaner pH Adjustment |
250mg/L |
| RADIX R97P | Reverse Osmosis Antiscalant | 8mg/L |
| RADIX pHB | Membrane Cleaner pH Adjustment |
250mg/L |
| SCALA P70 | Reverse Osmosis Antiscalant | 20mg/L |
| SCALONIL 65 | Reverse Osmosis Antiscalant | 8mg/L |
| SCALONIL NS | Reverse Osmosis Antiscalant | 20mg/L |
| SPARKON N65 | Reverse Osmosis Antiscalant | 8mg/L |
| SUNTOO PS8 | Reverse Osmosis Antiscalant | 20mg/L |
| WBC R100 | Reverse Osmosis Antiscalant | 8mg/L |
| pH PLUS | Membrane Cleaner pH Adjustment |
250mg/L |
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| ACUROCAR RO20 | Reverse Osmosis Membrane Biocide | NA |
| ACUROCIDE DB PLUS | Reverse Osmosis Membrane Biocide | NA |
| ACUROCIDE DB20 | Reverse Osmosis Membrane Biocide | NA |
| ACUROCIDE R13 | Reverse Osmosis Membrane Biocide | NA |
| ACUROCLEAN R21 | Membrane Cleaner | NA |
| ACUROX SP | Reverse Osmosis Membrane Biocide | NA |
| ACUROX SP10 | Reverse Osmosis Membrane Biocide | NA |
| ACUROX SP12 | Reverse Osmosis Membrane Biocide | NA |
| ACUROX SP15 | Reverse Osmosis Membrane Biocide | NA |
| ACUROX SP30 | Reverse Osmosis Membrane Biocide | NA |
| ACUROX SP8 | Reverse Osmosis Membrane Biocide | NA |
| CHEMICLEAN 21 | Membrane Cleaner | NA |
| Citric Acid | Membrane Cleaner | NA |
| Citric Acid Solution | Membrane Cleaner | NA |
| OXINEZ | Reverse Osmosis Membrane Biocide | NA |
| ROCIDE D20 | Reverse Osmosis Membrane Biocide | NA |
| ROCLEAN 27 | Membrane Cleaner | NA |
| ROCLEAR 21 | Membrane Cleaner | NA |
| ROKLEEN 21 | Membrane Cleaner | NA |
| ROKLEEN 24P | Membrane Cleaner | NA |
| ROKLEEN 27 | Membrane Cleaner | NA |
| ROKLEEN 29P | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Aquapharm Chemical Limited | |
| 9th & 10th floor, Amar Synergy | |
| Sadu Vaswani Road | |
| Pune 411001 | |
| India | |
| 91 20 66090000 | |
| Visit this company's website |
Facility : Mahad, Maharashtra, India
|
Aminotrimethylene Phosphonic Acid |
||
| Trade Designation | Product Function | Max Use |
| ATMP x.Na Salt | Reverse Osmosis Antiscalant Distillation Antiscalant |
20mg/L |
| Aquacid 1084 NS | Distillation Antiscalant Reverse Osmosis Antiscalant |
20mg/L |
| Aquacid-1086 NS | Reverse Osmosis Antiscalant Distillation Antiscalant |
20mg/L |
|
Hydroxyethylidene Diphosphonic Acid |
||
| Trade Designation | Product Function | Max Use |
| Aquacid 105 NS | Distillation Antiscalant Reverse Osmosis Antiscalant |
20mg/L |
| HEDP | Distillation Antiscalant Reverse Osmosis Antiscalant |
20mg/L |
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| Aquacid 106 NSVA | Distillation Antiscalant Reverse Osmosis Antiscalant |
20mg/L |
| Aquacid 106 NSVE | Distillation Antiscalant Reverse Osmosis Antiscalant |
20mg/L |
| Aquacid 1076 NSVA | Distillation Antiscalant Reverse Osmosis Antiscalant |
20mg/L |
| Aquacid 1076 NSVE | Distillation Antiscalant Reverse Osmosis Antiscalant |
20mg/L |
| MAXINOL 9000 NS | Reverse Osmosis Antiscalant Distillation Antiscalant |
20mg/L |
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| ATMP | Distillation Antiscalant Reverse Osmosis Antiscalant |
20mg/L |
| Aquacid 106 NS | Distillation Antiscalant Reverse Osmosis Antiscalant |
20mg/L |
| Aquacid 108 NS | Distillation Antiscalant Reverse Osmosis Antiscalant |
20mg/L |
| Aquacid-1076 NS | Distillation Antiscalant Reverse Osmosis Antiscalant |
20mg/L |
| DETMP | Distillation Antiscalant Reverse Osmosis Antiscalant |
20mg/L |
| HMDTMP x.K Salt | Reverse Osmosis Antiscalant Distillation Antiscalant |
20mg/L |
|
Polymaleic Acid |
||
| Trade Designation | Product Function | Max Use |
| PM 200 NS | Reverse Osmosis Antiscalant Distillation Antiscalant |
20mg/L |
| Polymaleic Acid | Reverse Osmosis Antiscalant Distillation Antiscalant |
20mg/L |
| Aquatech Systems (Asia) Pvt Ltd. | |
| Survey No 244/2, Rajiv Gandhi | |
| Infotech Park, Hinjewadi | |
| Pune, Maharashtra 411057 | |
| India | |
| 91 888 8826003 | |
| Visit this company's website |
Facility : Maharashtra, India
|
Miscellaneous Chemical Products |
||
| Trade Designation | Product Function | Max Use |
| MEMGARD 6001 | Reverse Osmosis Antiscalant | 20mg/L |
|
Miscellaneous Treatment Applications |
||
| Trade Designation | Product Function | Max Use |
| MEMGARD 6000 | Reverse Osmosis Antiscalant | 10mg/L |
| MEMGARD 6002 | Reverse Osmosis Antiscalant | 10mg/L |
| MEMGARD 6006 | Reverse Osmosis Antiscalant | 10mg/L |
| Memgard 6003 | Reverse Osmosis Antiscalant | 10mg/L |
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| MEMGARD 6016 | Membrane Cleaner | NA |
| MEMGARD 6017 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| ARISTA CHEMICALS LLP | |
| 57, Rakshak Housing Society | |
| Aundh Camp, Pimple Nilakh | |
| Pune, Maharashtra 411027 | |
| India | |
| 91 942 3035839 | |
| Visit this company's website |
Facility : Maharashtra, India
|
Sodium Permanganate[1] |
||
| Trade Designation | Product Function | Max Use |
| ARISOL 20 | Disinfection & Oxidation | 176mg/L |
| ARISOL 40™ | Disinfection & Oxidation | 88mg/L |
| Sodium Permanganate 20% | Disinfection & Oxidation | 176mg/L |
| Sodium Permanganate 40% | Disinfection & Oxidation | 88mg/L |
[1] The finished drinking water should be monitored to ensure that levels of manganese do
not exceed 0.05 mg/L.
|
||
| Black Diamond Chem | |
| Kh 92/13, | |
| Theri Baba Sawan Singh | |
| Sirsa, Haryana 125060 | |
| India | |
| 91 931 5124891 | |
| Visit this company's website |
Facility : Haryana, India
|
Potassium Permanganate[1] |
||
| Trade Designation | Product Function | Max Use |
| POTASSIUM PERMANGANTE (PURE GRADE MIN. 99%) | Oxidant | 50mg/L |
| Potassium Permanganate FFG (97%) | Oxidant | 50mg/L |
| Potassium Permanganate Technical (98%) | Oxidant | 50mg/L |
[1] The finished drinking water should be monitored to ensure that levels of manganese do
not exceed 0.05 mg/L
|
||
[PO] The finished drinking water shall be monitored to ensure that levels of manganese
do not exceed 0.05 mg/L.
| Bluestar Extrusion Pvt Ltd | |
| C. S. No. 168/BS No. 1, Prachiti Apt. | |
| Mahaveer Nagar, Vakharbhag | |
| Sangli, Maharashtra 416416 | |
| India | |
| 91 772 2005049 |
Facility : Maharashtra, India
|
Potassium Permanganate[1] |
||
| Trade Designation | Product Function | Max Use |
| Potassium Permanganate | Disinfection & Oxidation | 50mg/L |
| Potassium Permanganate (Crystal Grade Min. 99%) | Disinfection & Oxidation | 50mg/L |
| Potassium Permanganate (Fine Crystalline Powder Min. 99%) | Disinfection & Oxidation | 50mg/L |
| Potassium Permanganate (Free Flowing Grade Min. 97 %) | Disinfection & Oxidation | 50mg/L |
| Potassium Permanganate (Pure Bold Grade Min. 99 %) | Disinfection & Oxidation | 50mg/L |
| Potassium Permanganate (Pure Grade Min. 99 %) | Disinfection & Oxidation | 50mg/L |
| Potassium Permanganate (Technical Grade Min. 98 % and 99 %) | Disinfection & Oxidation | 50mg/L |
[1] The finished drinking water should be monitored to ensure that levels of manganese do
not exceed 0.05 mg/L.
|
||
[PO] The finished drinking water shall be monitored to ensure that levels of manganese
do not exceed 0.05 mg/L.
| Carus LLC | |
| 315 Fifth Street | |
| P.O. Box 599 | |
| Peru, IL 61354 | |
| United States | |
| 800-435-6856 | |
| 815-223-1500 | |
| Visit this company's website |
Facility : # 1A
|
Potassium Permanganate[PO] |
||
| Trade Designation | Product Function | Max Use |
| CARUS® Potassium Permanganate | Oxidant | 50mg/L |
[PO] The finished drinking water shall be monitored to ensure that levels of manganese
do not exceed 0.05 mg/L.
|
||
| Carus LLC | |
| 315 Fifth Street, PO Box 599 | |
| Peru, IL 61354 | |
| United States | |
| 800-435-6856 | |
| 815-223-1500 | |
| Visit this company's website |
Facility : # 1C
|
Potassium Permanganate[PO] |
||
| Trade Designation | Product Function | Max Use |
| CARUS® Potassium Permanganate | Oxidant | 50mg/L |
[PO] The finished drinking water shall be monitored to ensure that levels of manganese
do not exceed 0.05 mg/L.
|
||
| Carus LLC | |
| 315 Fifth Street | |
| P.O. Box 599 | |
| Peru, IL 61354 | |
| United States | |
| 800-435-6856 | |
| 815-223-1500 | |
| Visit this company's website |
Facility : # 1B
|
Potassium Permanganate[PO] |
||
| Trade Designation | Product Function | Max Use |
| CARUS® Potassium Permanganate | Oxidant | 50mg/L |
[PO] The finished drinking water shall be monitored to ensure that levels of manganese
do not exceed 0.05 mg/L.
|
||
| Carus LLC | |
| 315 Fifth Street | |
| P.O. Box 599 | |
| Peru, IL 61354 | |
| United States | |
| 800-435-6856 | |
| 815-223-1500 | |
| Visit this company's website |
Facility : # 1D
|
Sodium Permanganate[1] |
||
| Trade Designation | Product Function | Max Use |
| CARUS® Sodium Permanganate | Disinfection & Oxidation | 88mg/L |
[1] The finished drinking water should be monitored to ensure that levels of manganese do
not exceed 0.05 mg/L.
|
||
| Carus LLC | |
| 315 Fifth Street | |
| P.O. Box 599 | |
| Peru, IL 61354 | |
| United States | |
| 800-435-6856 | |
| 815-223-1500 | |
| Visit this company's website |
Facility : # 1E
|
Potassium Permanganate[PO] |
||
| Trade Designation | Product Function | Max Use |
| CARUS® Potassium Permanganate | Oxidant | 50mg/L |
[PO] The finished drinking water shall be monitored to ensure that levels of manganese
do not exceed 0.05 mg/L.
|
||
| Chembond Water Technologies Limited | |
| EL-37, Chembond Centre, MIDC | |
| Mahape, Navi Mumbai | |
| Thane, MM 400710 | |
| India | |
| 91 932 4816592 | |
| Visit this company's website |
Facility : Gujarat, India
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| KEM WATREAT R 170 | Reverse Osmosis Antiscalant | 15mg/L |
| Kem Antifoam 1795[1] | Antifoamer | 10mg/L |
| Kem Watreat B 10 L[2] | Dechlorination | 250mg/L |
| Kem Watreat B 20 | pH Adjustment | 25mg/L |
| Kem Watreat B 7 | Scale Control | 30mg/L |
| Kem Watreat R 3687 | Reverse Osmosis Antiscalant Distillation Antiscalant |
10mg/L |
| Kem Watreat R 428I | Reverse Osmosis Antiscalant | 10mg/L |
[1] Certified for addition to the feedwater for evaporative desalination units only.
[2] This product contains sulfite. Sulfites have been known to cause potentially lethal
allergic reactions in sulfite-sensitive individuals. The maximum recommended allowable
residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).
|
||
|
Sodium Chlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| Kem Watreat CA 1 | Chlorine Dioxide Production | 10mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
NOTE: Only products bearing the NSF Mark on product packaging and documentation are certified.
| Chempure Technologies Pvt. Ltd. | |
| 63, Fifth street, Rajagopalapuram, | |
| Mowlivakkam | |
| Chennai, TA 600125 | |
| India | |
| +91-44-23821882 |
Facility : Chennai, India
|
MISC. WATER SUPPLY PRODUCTS |
||
| Trade Designation | Product Function | Max Use |
| CHEMPURE 516 | Reverse Osmosis Antiscalant | 10mg/L |
| Chemrite, Inc. | |
| 5202 Belle Wood Court | |
| Suite 104 | |
| Buford, GA 30518 | |
| United States | |
| 877-828-1652 | |
| 770-271-5578 | |
| Visit this company's website |
Facility : Andhra Pradesh, India
|
Calcium Hypochlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| ProChlo | Disinfection & Oxidation | 10mg/L |
| ProChlo Plus | Disinfection & Oxidation | 10mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| Cochin Minerals and Rutile Limited | |
| Market Road | |
| Alwaye, Kerala 683 101 | |
| India | |
| 91 484 262 6789 | |
| Visit this company's website |
Facility : # 1 India
|
Ferric Chloride[1] |
||
| Trade Designation | Product Function | Max Use |
| FERRIC CHLORIDE | Coagulation & Flocculation | 500mg/L |
| IRON III CHLORIDE | Coagulation & Flocculation | 500mg/L |
[1] End product is 40-42% Ferric Chloride. |
||
|
Ferrous Chloride |
||
| Trade Designation | Product Function | Max Use |
| FERROUS CHLORIDE | Coagulation & Flocculation | 500mg/L |
| FERROUS CHLORIDE WITH HYDRATED TITANIA | Coagulation & Flocculation | 500mg/L |
| IRON II CHLORIDE | Coagulation & Flocculation | 500mg/L |
| IRON II CHLORIDE WITH HYDRATED TITANIA | Coagulation & Flocculation | 500mg/L |
| DAFFODIL PHARMACHEM PRIVATE LIMITED | |
| A-2304, Privilon, 23rd Floor, B/H Iskcon | |
| Temple, Ambli-Bopal Road, S.G Highway | |
| Ahmedabad, Gujarat 380054 | |
| India | |
| 91 79 26449966 | |
| Visit this company's website |
Facility : # 1 India
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Citric Acid Anhydrous | Membrane Cleaner | NA |
| Citric Acid Monohydrate | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Sodium Citrate | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
| Dodhia Chem-Tex Pvt. Ltd. | |
| 98/2, Dodhia House, New Mavjil Compound | |
| Narpoli, Behind Ratan Talkies, Dist. | |
| Thane, Bhiwandi, Maharashtra 421302 | |
| India | |
| 91 996 0864000 | |
| Visit this company's website |
Facility : Maharashtra, India
|
Calcium Hypochlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| AQUA-CLEAR | Disinfection & Oxidation Algicide |
13mg/L |
| AQUA-DO | Disinfection & Oxidation Algicide |
13mg/L |
| Bleaching Powder | Disinfection & Oxidation Algicide |
13mg/L |
| CHLORI CLEAR | Disinfection & Oxidation Algicide |
13mg/L |
| CHLORI DO | Disinfection & Oxidation Algicide |
13mg/L |
| CRYSTAL AQUA | Disinfection & Oxidation Algicide |
13mg/L |
| CRYSTAL CHLOR | Disinfection & Oxidation Algicide |
13mg/L |
| Calcium Hypochlorite | Disinfection & Oxidation Algicide |
13mg/L |
| Calcium Oxychloride | Disinfection & Oxidation Algicide |
13mg/L |
| Chlorinated Lime | Disinfection & Oxidation Algicide |
13mg/L |
| HI-CHLOR + | Disinfection & Oxidation Algicide |
13mg/L |
| HI-CLEAR + | Disinfection & Oxidation Algicide |
13mg/L |
| Hi Clear | Disinfection & Oxidation Algicide |
13mg/L |
| Stable Bleaching Powder | Disinfection & Oxidation Algicide |
13mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| Envocrystal India Pvt. Ltd. | |
| 158/1, Shree Swami Samarth Building | |
| Sector-6, Nerul (W) | |
| Navi Mumbai, Maharashtra 400706 | |
| India | |
| 91 969 9758494 | |
| Visit this company's website |
Facility : Maharashtra, India
|
Chlorine Dioxide Ingredients[1] [CL] |
||
| Trade Designation | Product Function | Max Use |
| MICROSLAY | Algicide Bactericide Disinfection & Oxidation |
13mg/L |
[1] Microslay A and Microslay B are to be mixed following the manufacturer's use
instructions to produce 0.6% chlorine dixoide solution. Certification applies to the
finished product.
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| Excel Industries Limited | |
| 184-187, S.V. Road | |
| Mumbai West | |
| Jogeshwari 400102 | |
| India | |
| 91 222 6782508 | |
| Visit this company's website |
Facility : Maharashtra, India
|
Aminotrimethylene Phosphonic Acid |
||
| Trade Designation | Product Function | Max Use |
| Codex 8503 | Reverse Osmosis Antiscalant | 20mg/L |
| Codex 9403 | Reverse Osmosis Antiscalant | 25mg/L |
|
Diethylenetriamine penta (methylene phosphonic) ac |
||
| Trade Designation | Product Function | Max Use |
| Codex 4473N | Reverse Osmosis Antiscalant | 20mg/L |
| Codex 4483 | Reverse Osmosis Antiscalant | 20mg/L |
| Codex 4503 | Reverse Osmosis Antiscalant | 20mg/L |
|
Hydroxyethylidene Diphosphonic Acid |
||
| Trade Designation | Product Function | Max Use |
| Codex 1000 | Distillation Antiscalant Reverse Osmosis Antiscalant |
15mg/L |
| Codex 661 | Distillation Antiscalant Reverse Osmosis Antiscalant |
20mg/L |
| Codex 661LC | Distillation Antiscalant Reverse Osmosis Antiscalant |
20mg/L |
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| Finor Piplaj Chemicals Limited | |
| EL- 37 | |
| Mahape MIDC, Navi Mumbai | |
| Maharashtra 400710 | |
| India | |
| 91 766 6657705 | |
| Visit this company's website |
Facility : Gujarat, India
|
Aminotrimethylene Phosphonic Acid |
||
| Trade Designation | Product Function | Max Use |
| Finor CWT 4010 | Reverse Osmosis Antiscalant | 25mg/L |
NOTE: Only products bearing the NSF Mark on product packaging and documentation are certified.
| Grasim Industries Limited, Chemical Division | |
| Birlagram, Nagda, District Ujjain | |
| Madhya Pradesh 456331 | |
| India | |
| 91 736 6245848 | |
| Visit this company's website |
Facility : Andhra Pradesh, India
|
Sodium Hydroxide |
||
| Trade Designation | Product Function | Max Use |
| CAUSTIC SODA FLAKES | pH Adjustment Corrosion & Scale Control |
800mg/L |
Facility : Gujarat, India
|
Aluminum Chlorohydrate[AL] |
||
| Trade Designation | Product Function | Max Use |
| Aluminium Chlorohydrate | Coagulation & Flocculation | 250mg/L |
| VYTAL HBC Supra | Coagulation & Flocculation | 250mg/L |
| VYTAL S Co | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Calcium Hypochlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| AQUA ARMOR HSD Prime | Disinfection & Oxidation Algicide |
10mg/L |
| POWEFRIT IPC | Disinfection & Oxidation Algicide |
10mg/L |
| RENSA HS Bleach | Disinfection & Oxidation Algicide |
10mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| AC/100S | Coagulation & Flocculation | 200mg/L |
| ARYAPAC | Coagulation & Flocculation | 200mg/L |
| POLYALUMINIUM CHLORIDE (LIQUID) | Coagulation & Flocculation | 200mg/L |
| SAB 18 | Coagulation & Flocculation | 200mg/L |
| SAB 18 Plus (Liquid) | Coagulation & Flocculation | 200mg/L |
| SAB 18 Plus (Powder) | Coagulation & Flocculation | 200mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Polymer Blends[AL] |
||
| Trade Designation | Product Function | Max Use |
| Vytal 3305 | Coagulation & Flocculation | 250mg/L |
| Vytal 3306 | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Sodium Hydroxide |
||
| Trade Designation | Product Function | Max Use |
| CAUSTIC SODA FLAKES | Corrosion & Scale Control pH Adjustment |
800mg/L |
Facility : Jharkhand, India
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| AC 100S Liquid | Coagulation & Flocculation | 200mg/L |
| AC 100S Powder | Coagulation & Flocculation | 200mg/L |
| ARYA PAC Liquid | Coagulation & Flocculation | 200mg/L |
| ARYA PAC Powder | Coagulation & Flocculation | 200mg/L |
| SAB 18 Liquid | Coagulation & Flocculation | 200mg/L |
| SAB 18 Powder | Coagulation & Flocculation | 200mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Sodium Hydroxide |
||
| Trade Designation | Product Function | Max Use |
| CAUSTIC SODA FLAKES | Corrosion & Scale Control pH Adjustment |
800mg/L |
Facility : Madhya Pradesh, India
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| AC/100S | Coagulation & Flocculation | 200mg/L |
| ARYAPAC | Coagulation & Flocculation | 200mg/L |
| POLYALUMINIUM CHLORIDE (LIQUID) | Coagulation & Flocculation | 200mg/L |
| SAB 18 | Coagulation & Flocculation | 200mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
Facility : Odisha, India
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| AC100S (Liquid) | Coagulation & Flocculation | 200mg/L |
| AC100S (Powder) | Coagulation & Flocculation | 200mg/L |
| ARYAPAC (Liquid) | Coagulation & Flocculation | 200mg/L |
| ARYAPAC (Powder) | Coagulation & Flocculation | 200mg/L |
| SAB 18 (Liquid) | Coagulation & Flocculation | 200mg/L |
| SAB 18 (Powder) | Coagulation & Flocculation | 200mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
Facility : Renukoot, India
|
Hydrochloric Acid |
||
| Trade Designation | Product Function | Max Use |
| Hydrochloric Acid | Corrosion & Scale Control Descaler |
50mg/L |
Facility : Veraval, Gujarat, India
|
Sodium Hydroxide |
||
| Trade Designation | Product Function | Max Use |
| CAUSTIC SODA FLAKES | Corrosion & Scale Control pH Adjustment |
800mg/L |
| Gujarat Alkalies and Chemicals Limited | |
| PO Dahej, Tal Vagra | |
| Bharuch, Gujarat 391346 | |
| India | |
| 91 265 2232681 |
Facility : Bharuch, Gujarat, India
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| PAC10 | Coagulation & Flocculation | 200mg/L |
| PAC30 | Coagulation & Flocculation | 200mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Sodium Hydroxide |
||
| Trade Designation | Product Function | Max Use |
| Caustic Soda Flakes | Corrosion & Scale Control pH Adjustment |
800mg/L |
| Caustic Soda Lye Rayan Grade-Min 47% | Corrosion & Scale Control pH Adjustment |
800mg/L |
| Caustic Soda Prills | Corrosion & Scale Control pH Adjustment |
800mg/L |
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| Gulbrandsen Technologies (India) Pvt. Ltd. | |
| 405 Synergy Square, Krishna Indl Est. | |
| Gorwa, Vadodara, Gujarat 390005 | |
| India | |
| 91 265 392 7500 | |
| Visit this company's website |
Facility : District Bharuch, Gujarat, India
|
Aluminum Chlorohydrate[AL] |
||
| Trade Designation | Product Function | Max Use |
| AdClear 200G | Coagulation & Flocculation | 350mg/L |
| GC 849 MO | Coagulation & Flocculation | 250mg/L |
| GC 850 | Coagulation & Flocculation | 350mg/L |
| GC 850D | Coagulation & Flocculation | 125mg/L |
| GPAC 2800 | Coagulation & Flocculation | 350mg/L |
| GPAC 2800D | Coagulation & Flocculation | 125mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Aluminum Hydroxychloride [AL] |
||
| Trade Designation | Product Function | Max Use |
| GC WXY-ZZ[1] | Coagulation & Flocculation | 250mg/L |
[1] AA - 15 - 99.5
BB - 0.5 - 25
CC - 15 - 99.5
DD - 26 - 55
X - 1 - 3
Y - 4 - 6
ZZ - 20 - 99.5
WW - 0.5 - 30
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| AdClear 200G | Coagulation & Flocculation | 350mg/L |
| GC 849 MO | Coagulation & Flocculation | 250mg/L |
| GC 850 | Coagulation & Flocculation | 350mg/L |
| GC 850D | Coagulation & Flocculation | 125mg/L |
| GPAC 2800 | Coagulation & Flocculation | 350mg/L |
| GPAC 2800D | Coagulation & Flocculation | 125mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Polymer Blends [AL] |
||
| Trade Designation | Product Function | Max Use |
| GC 80 AABB[2] | Coagulation & Flocculation | 100mg/L |
| GC 80 CCDD[2] | Coagulation & Flocculation | 45mg/L |
| GC 803-7030[1] [PY] | Coagulation & Flocculation | 33mg/L |
| GC 8035-603010[1] [PY] | Coagulation & Flocculation | 33mg/L |
| GC 80X10-20ZZWW[1] [PY] | Coagulation & Flocculation | 50mg/L |
| GC 80Y25-30ZZWW[2] | Coagulation & Flocculation | 83mg/L |
[1] AA - 15 - 99.5
BB - 0.5 - 25
CC - 15 - 99.5
DD - 26 - 55
X - 1 - 3
Y - 4 - 6
ZZ - 20 - 99.5
WW - 0.5 - 30
[2] AA = 15 - 99.5
BB = 0.5 - 25
CC = 15 - 99.5
DD = 26 - 55
Y = 4 -6
ZZ = 20 - 99.5
WW = 0.5 - 30
AA = % Concentration of GC 850 in the final bend
BB = Polydadmac 40% concentration in the final blend
CC = % Concentration of GC 850 in the final blend
DD = Polydadmac 40% concentration in the final blend
Y = 40% Polydadmac grade
ZZ = % Concentration of GC 850 in the final blend
WW = % Total polydadmac concentration in the final blend
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
percent monomer and dose.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| Gulbrandsen Technologies Malaysia Sdn. Bhd. | |
| 7, Jln Permata 2A/KS9, Tmn Perindustrian | |
| Air Hitam, Klang, Selangor 41200 | |
| Malaysia | |
| 603 312 31288 | |
| Visit this company's website |
Facility : Gujarat, India
|
Aluminum Chlorohydrate[AL] |
||
| Trade Designation | Product Function | Max Use |
| GC 849 MO | Coagulation & Flocculation | 250mg/L |
| GC 850 | Coagulation & Flocculation | 350mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| GC 849 MO | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
| HIND PHARMA | |
| 11-G, JK ROAD | |
| INDUSTRIAL AREA | |
| GOVINDPURA | |
| BHOPAL, MP 462022 | |
| India | |
| 91 9425997474 | |
| Visit this company's website |
Facility : Bhopal, India
|
Sodium Dichloroisocyanurate |
||
| Trade Designation | Product Function | Max Use |
| Aquapurify | Disinfection & Oxidation | 6mg/L |
| Bio-Tab | Disinfection & Oxidation | 6mg/L |
| Ef-Chlor | Disinfection & Oxidation | 6mg/L |
| Effi-Sept | Disinfection & Oxidation | 6mg/L |
| NeerChlor | Disinfection & Oxidation | 6mg/L |
| NeutraChlor | Disinfection & Oxidation | 6mg/L |
| Primal Survival | Disinfection & Oxidation | 6mg/L |
| Purifast | Disinfection & Oxidation | 6mg/L |
| Thyroshield | Disinfection & Oxidation | 6mg/L |
| Indian Desalination Engineering Pvt. Ltd. | |
| Plot No. 67, Shed No. D-3/14 | |
| Corlim Industrial Estate, Corlim, Ilhas. | |
| Panaji, Goa 403110 | |
| India | |
| 91 832 228 4010 |
Facility : Panaji, Goa, India
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| IN - 204 | Distillation Antiscalant Reverse Osmosis Antiscalant |
10mg/L |
| IN - 204 - AS | Distillation Antiscalant Reverse Osmosis Antiscalant |
10mg/L |
| Scale Inhabitors | Distillation Antiscalant Reverse Osmosis Antiscalant |
10mg/L |
| Jal Aqua International | |
| 603, Rajhans Tower, Varachha Road | |
| Surat, Gujarat 395006 | |
| India | |
| 91 899 9933339 | |
| Visit this company's website |
Facility : Ankleshwar, Gujarat, India
|
Calcium Hypochlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| AQUATICK DISINFECTANT CHLORINATING GRANULES | Algicide Disinfection & Oxidation |
12mg/L |
| AQUATICK PROCLEAN | Algicide Disinfection & Oxidation |
12mg/L |
| AX POOLWINSK ADVANCED POOL SHOCK | Algicide Disinfection & Oxidation |
12mg/L |
| CALCIUM HYPOCHLORITE 65% | Algicide Disinfection & Oxidation |
12mg/L |
| CALCIUM HYPOCHLORITE 70% | Algicide Disinfection & Oxidation |
12mg/L |
| CHLORA WATER TREATMENT COMPOUND | Algicide Disinfection & Oxidation |
12mg/L |
| DISINFECTANT CHLORINATED LIME | Algicide Disinfection & Oxidation |
12mg/L |
| DY CHOLON GRANULER 70 | Algicide Disinfection & Oxidation |
12mg/L |
| HI GRADE STABLE BLEACHING GRANULES ( HSBP) | Algicide Disinfection & Oxidation |
12mg/L |
| HS BLEACH GRANULES | Algicide Disinfection & Oxidation |
12mg/L |
| JAL CLEAR CALCIUM HYPOCHLORITE 65-70% | Algicide Disinfection & Oxidation |
12mg/L |
| MEDIPRO SHIELD | Algicide Disinfection & Oxidation |
12mg/L |
| POOL SHARK | Algicide Disinfection & Oxidation |
12mg/L |
| POOL WORLD GRANULAR | Algicide Disinfection & Oxidation |
12mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| Jay Chemical Industries Private LImited | |
| Jay House, Panchvati Circle, Ambawadi | |
| AHMEDABAD, GJ 380006 | |
| India | |
| +91 9909908169 | |
| Visit this company's website |
Facility : Gujarat, India
|
Citric Acid |
||
| Trade Designation | Product Function | Max Use |
| AKWA RC 5022 | Membrane Cleaner | NA |
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| AKWA BL 2100[1] | Reverse Osmosis Antiscalant | 20mg/L |
| AKWA RA 6501 | Reverse Osmosis Antiscalant | 5mg/L |
| AKWA RA 6601 | Reverse Osmosis Antiscalant | 5mg/L |
[1] This product contains sulfite. |
||
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| AKWA RC 5012[2] | Membrane Cleaner | NA |
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
|
Sodium Hydroxide |
||
| Trade Designation | Product Function | Max Use |
| AKWA BL 2300 | pH Adjustment | 5mg/L |
| Kakadiya Chemicals | |
| Plot No. 2807, GIDC Estate | |
| Ankleshwar, GJ 393002 | |
| India | |
| 91 9033552220 | |
| Visit this company's website |
Facility : Gujarat, India
|
Calcium Hypochlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| CALCIUM HYPOCHLORITE 65-70% | Disinfection & Oxidation | 10mg/L |
| CALCIUM HYPOCHLORITE 70% | Disinfection & Oxidation | 10mg/L |
| CHLORA | Disinfection & Oxidation | 10mg/L |
| CHLORA + | Disinfection & Oxidation | 10mg/L |
| CHLORA BLEACH GRANULES | Disinfection & Oxidation | 10mg/L |
| CHLORA CHLORINATED LIME | Disinfection & Oxidation | 10mg/L |
| CHLORA DISINFECTANT GRANULES | Disinfection & Oxidation | 10mg/L |
| CHLORA HI STRENTH BLEACHING GRANULES | Disinfection & Oxidation | 10mg/L |
| CHLORA PLUS DRY CHLORINE | Disinfection & Oxidation | 10mg/L |
| CHLORA SUPER | Disinfection & Oxidation | 10mg/L |
| CHLORA SWIM-POOL | Disinfection & Oxidation | 10mg/L |
| CHLORA WATER TREATMENT CHEMICAL | Disinfection & Oxidation | 10mg/L |
| DI CHLON GRANULER 70 | Disinfection & Oxidation | 10mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| KEMOX CORPORATION | |
| Survey No. 87/1/1/2/2, Umerkoi Road | |
| Near Alok Industries, Falandi Village | |
| Silvassa, Dadra & Nagar Haveli 396230 | |
| India | |
| 91 22 61166100 | |
| Visit this company's website |
Facility : Dadra & Nagar Haveli, India
|
Sodium Permanganate[1] |
||
| Trade Designation | Product Function | Max Use |
| SODIUM PERMANGANATE 40% | Oxidant Disinfection & Oxidation |
88mg/L |
[1] The finished drinking water should be monitored to ensure that levels of manganese do
not exceed 0.05 mg/L.
|
||
| Krasoma Biochem Private Limited | |
| Plot No. 254, Sector 3 | |
| Pithampur, Madhya Pradesh 454775 | |
| India | |
| 91 982 6626881 |
Facility : Pithampur, India
|
Ferric Chloride |
||
| Trade Designation | Product Function | Max Use |
| FERRIC CHLORIDE ANHYDROUS (KC100) | Coagulation & Flocculation | 100mg/L |
| FERRIC CHLORIDE SOLUTION (KC40) | Coagulation & Flocculation | 250mg/L |
| Magnesia Chemicals LLP | |
| 57, Rakshak Co-Op HSG Soc. | |
| S. No. 32 to 37, Pimple Nilakh, Aundh Cp. | |
| Pune Maharashtra 411027 | |
| India | |
| 91 942 3035839 | |
| Visit this company's website |
Facility : Satara, Maharashtra, India
|
Potassium Permanganate[PO] |
||
| Trade Designation | Product Function | Max Use |
| POTASSIUM PERMANGANATE | Oxidant | 50mg/L |
| POTASSIUM PERMANGANATE - FFG GRADE | Oxidant | 50mg/L |
| POTASSIUM PERMANGANATE - PURE GRADE | Oxidant | 50mg/L |
| POTASSIUM PERMANGANATE - TECHNICAL GRADE | Oxidant | 50mg/L |
| Potassium Permanganate - MAGFFLOX | Oxidant | 50mg/L |
| Potassium Permanganate - MAGNEEDLES | Oxidant | 50mg/L |
| Potassium Permanganate - MAGPURE | Oxidant | 50mg/L |
| Potassium Permanganate - MAGTABS | Oxidant | 50mg/L |
| Potassium Permanganate - MAGTABS Plus | Oxidant | 50mg/L |
| Potassium Permanganate - MAGTECH | Oxidant | 50mg/L |
| Potassium Permanganate - Tablets | Oxidant | 50mg/L |
[PO] The finished drinking water shall be monitored to ensure that levels of manganese
do not exceed 0.05 mg/L.
|
||
| Maulikem Products Pvt. Ltd. | |
| #31, 4th Floor Shrikrishan Center, Near | |
| Mithakhali Six Roads, Navrangpura | |
| Ahmedabad, Gujarat 380009 | |
| India | |
| 91 792 6463625 | |
| Visit this company's website |
Facility : Gujarat, India
|
Sodium Chlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| MKP75 | Chlorine Dioxide Production | 9mg/L |
| MKP30 | Chlorine Dioxide Production | 23mg/L |
| MKP25 | Chlorine Dioxide Production | 28mg/L |
| MKP31 | Chlorine Dioxide Production | 22mg/L |
| MKP80 | Chlorine Dioxide Production | 8mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| Motagane Chem Works CC | |
| Irene Link Building E, Second Floor | |
| 5 Impala Avenue, Doringkloof | |
| Centurion, Gauteng 0157 | |
| South Africa | |
| 27 012 348 1943 |
Facility : # 1 Gujarat, India
|
Polymer Blends[1] [AL] |
||
| Trade Designation | Product Function | Max Use |
| Crystal 3542 | Coagulation & Flocculation | 45mg/L |
| Crystal 5032 | Coagulation & Flocculation | 45mg/L |
| Crystal 7016 | Coagulation & Flocculation | 100mg/L |
[1] AA = 15 - 99.5
BB = 0.5 - 25
CC = 15 - 99.5
DD = 26 - 55
Y = 4 -6
ZZ = 20 - 99.5
WW = 0.5 - 30
AA = % Concentration of GC 850 in the final bend
BB = Polydadmac 40% concentration in the final blend
CC = % Concentration of GC 850 in the final blend
DD = Polydadmac 40% concentration in the final blend
Y = 40% Polydadmac grade
ZZ = % Concentration of GC 850 in the final blend
WW = % Total polydadmac concentration in the final blend
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
| Nalco Company | |
| 1601 West Diehl Road | |
| Naperville, IL 60563-1198 | |
| United States | |
| 630-305-1000 | |
| Visit this company's website |
Facility : #4110 India
|
Aluminum Chlorohydrate[AL] |
||
| Trade Designation | Product Function | Max Use |
| ULTRION™ 8187 | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Calcium Hypochlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| NALCO® 2592 | Disinfection & Oxidation | 10mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| NALCO® PC-2040 | Distillation Antiscalant Reverse Osmosis Antiscalant |
20mg/L |
| PC-1638T | Reverse Osmosis Antiscalant | 15mg/L |
| PermaTreat™ PC-1020T | Reverse Osmosis Antiscalant | 26mg/L |
| PermaTreat™ PC-191 | Reverse Osmosis Antiscalant | 15mg/L |
| PermaTreat™ PC-191T | Reverse Osmosis Antiscalant | 15mg/L |
| PermaTreat™ PC-391T | Reverse Osmosis Antiscalant | 45mg/L |
| PermaTreat™ PC-510T | Reverse Osmosis Antiscalant | 10mg/L |
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| NALCO® PC-2040 | Distillation Antiscalant Reverse Osmosis Antiscalant |
20mg/L |
| NALCO® PC-2040T | Reverse Osmosis Antiscalant Distillation Antiscalant |
20mg/L |
|
Miscellaneous Water Supply Products[3] |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-11 | Reverse Osmosis Membrane Biocide | NA |
[3] Certified for use as an off-line membrane cleaner. When used as an off-line membrane
cleaner, this product is designed to be flushed out prior to using the system for
drinking water. Follow manufacturer's use instructions.
|
||
|
Miscellaneous Water Supply Products[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-33 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water shall be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-67 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
|
||
|
Miscellaneous Water Supply Products[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-77 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
| Nalco PC-98 | Membrane Cleaner | NA |
| Nalco PC-98 | Membrane Cleaner | NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water shall be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[3] |
||
| Trade Designation | Product Function | Max Use |
| PermaClean™ PC-11 | Reverse Osmosis Membrane Biocide | NA |
[3] Certified for use as an off-line membrane cleaner. When used as an off-line membrane
cleaner, this product is designed to be flushed out prior to using the system for
drinking water. Follow manufacturer's use instructions.
|
||
|
Miscellaneous Water Supply Products[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| PermaClean™ PC-33 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
| PermaClean™ PC-40 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water shall be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| PermaClean™ PC-67 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
|
||
|
Miscellaneous Water Supply Products[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| PermaClean™ PC-77 | Membrane Cleaner Reverse Osmosis Antiscalant |
NA |
| PermaClean™ PC-98 | Membrane Cleaner | NA |
[1] These products are designed to be used off-line and flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water shall be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Poly (Diallyldimethylammonium Chloride)(pDADMAC) |
||
| Trade Designation | Product Function | Max Use |
| Cat-Floc 8102 Plus | Coagulation & Flocculation | 50mg/L |
| Cat-Floc T | Coagulation & Flocculation | 50mg/L |
|
Polyacrylamide[PC] |
||
| Trade Designation | Product Function | Max Use |
| Nalclear 8170 PULV | Coagulation & Flocculation | 1mg/L |
| Nalclear 8173 PULV | Coagulation & Flocculation | 1mg/L |
[PC] Polyacrylamide Products Certified by NSF International comply with 40 CFR 141.111
requirements for percent monomer and dose.
|
||
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| ULTRION™ 8187 | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Polyamines[PY] |
||
| Trade Designation | Product Function | Max Use |
| NALCOLYTE™ 8100 | Coagulation & Flocculation | 10mg/L |
| NALCOLYTE™ 8105 | Coagulation & Flocculation | 10mg/L |
[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
percent monomer and dose.
|
||
|
Polymer Blends[AL] [PY] |
||
| Trade Designation | Product Function | Max Use |
| ULTRION™ 8185 | Coagulation & Flocculation | 20mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
percent monomer and dose.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
Facility : #4111 India
|
Aluminum Chlorohydrate[AL] |
||
| Trade Designation | Product Function | Max Use |
| Ultrion 8187 | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Calcium Hypochlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| NALCO® 2592 | Disinfection & Oxidation | 10mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
|
Miscellaneous Treatment Applications |
||
| Trade Designation | Product Function | Max Use |
| PERMATREAT™ PC-1630T | Reverse Osmosis Antiscalant | 10mg/L |
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| NALCO® PC-2040 | Reverse Osmosis Antiscalant Distillation Antiscalant |
25mg/L |
| NALCO® PC-2040T | Reverse Osmosis Antiscalant Distillation Antiscalant |
20mg/L |
| PermaTreat™ PC-1020T | Reverse Osmosis Antiscalant | 26mg/L |
| PermaTreat™ PC-510T | Reverse Osmosis Antiscalant | 10mg/L |
| Permatreat® PC-191T | Reverse Osmosis Antiscalant | 15mg/L |
| Permatreat® PC-391T | Reverse Osmosis Antiscalant | 45mg/L |
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| Nalco PC-11[1] | Reverse Osmosis Membrane Biocide | NA |
| Nalco PC-33[1] [2] | Reverse Osmosis Antiscalant Membrane Cleaner |
NA |
| Nalco PC-67[1] | Reverse Osmosis Antiscalant Membrane Cleaner |
NA |
| Nalco PC-77[1] [2] | Reverse Osmosis Antiscalant Membrane Cleaner |
NA |
| Nalco PC-98[1] [2] | Membrane Cleaner | NA |
| PermaClean™ PC-11[1] | Reverse Osmosis Membrane Biocide | NA |
| PermaClean™ PC-33[1] [2] | Reverse Osmosis Antiscalant Membrane Cleaner |
NA |
| PermaClean™ PC-40[1] [2] | Reverse Osmosis Antiscalant Membrane Cleaner |
NA |
| PermaClean™ PC-67[1] | Reverse Osmosis Antiscalant Membrane Cleaner |
NA |
| PermaClean™ PC-77[1] [2] | Reverse Osmosis Antiscalant Membrane Cleaner |
NA |
| PermaClean™ PC-98[1] [2] | Membrane Cleaner | NA |
| PermaTreat PC-504T | Reverse Osmosis Antiscalant | 15mg/L |
| PermaTreat PC-510T | Reverse Osmosis Antiscalant | 10mg/L |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following the manufacturer's use instructions.
[2] This pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Polyacrylamide[PC] |
||
| Trade Designation | Product Function | Max Use |
| Nalclear 8170 PULV | Coagulation & Flocculation | 1mg/L |
| Nalclear 8173 PULV | Coagulation & Flocculation | 1mg/L |
[PC] Polyacrylamide Products Certified by NSF International comply with 40 CFR 141.111
requirements for percent monomer and dose.
|
||
|
Polyaluminum Chloride[AL] |
||
| Trade Designation | Product Function | Max Use |
| Ultrion 8187 | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Polymer Blends |
||
| Trade Designation | Product Function | Max Use |
| FERRALYTE™ 8130 | Coagulation & Flocculation | 150mg/L |
| ULTRION™ 8185[AL] [PY] | Coagulation & Flocculation | 20mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
percent monomer and dose.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| Nalco Company | |
| 1601 W Diehl Rd | |
| Naperville, IL 60563 | |
| United States | |
| 630-305-1578 | |
| Visit this company's website |
Facility : 4199 India
|
Chlorine Dioxide Ingredients[CL] |
||
| Trade Designation | Product Function | Max Use |
| NALCO® 2595A | Algicide Bactericide Disinfection & Oxidation |
50mg/L |
| NALCO® 2595B | Algicide Bactericide Disinfection & Oxidation |
50mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
[1] Component A and Component B are to be mixed following manufacturer's use instructions to
produce a 1% chlorine dioxide solution. Certification and maximum use level applies to
the finished product.
| Organic Industries Private Limited | |
| 601/602, 6th Floor, Delta Building | |
| Technology Street, Hiranandani Gardens | |
| Powai, Mumbai 400076 | |
| India | |
| 91 22 41622828 | |
| Visit this company's website |
Facility : Gujarat, India
|
Calcium Hypochlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| AQUA - CHLORONICS | Algicide Disinfection & Oxidation |
15mg/L |
| AQUA - ORG | Algicide Disinfection & Oxidation |
15mg/L |
| Aqua-Chloronics 65% | Algicide Disinfection & Oxidation |
15mg/L |
| Aqua-Chloronics 65-70% | Algicide Disinfection & Oxidation |
15mg/L |
| Aqua-Chloronics 70% | Algicide Disinfection & Oxidation |
15mg/L |
| Aqua-Org 65% | Algicide Disinfection & Oxidation |
15mg/L |
| Aqua-Org 65-70% | Algicide Disinfection & Oxidation |
15mg/L |
| Aqua-Org 70% | Algicide Disinfection & Oxidation |
15mg/L |
| Aqua-Org Plus 65% | Algicide Disinfection & Oxidation |
15mg/L |
| Aqua-Org Plus 65-70% | Algicide Disinfection & Oxidation |
15mg/L |
| Aqua-Org Plus 70% | Algicide Disinfection & Oxidation |
15mg/L |
| Aqua-Org Supreme 65% | Algicide Disinfection & Oxidation |
15mg/L |
| Aqua-Org Supreme 65-70% | Algicide Disinfection & Oxidation |
15mg/L |
| Aqua-Org Supreme 70% | Algicide Disinfection & Oxidation |
15mg/L |
| Aquafarm 65% | Algicide Disinfection & Oxidation |
15mg/L |
| Aquafarm 65-70% | Algicide Disinfection & Oxidation |
15mg/L |
| Aquafarm 70% | Algicide Disinfection & Oxidation |
15mg/L |
| CALCIUM HYPO CHLORITE | Algicide Disinfection & Oxidation |
15mg/L |
| CHLORO - JAL | Algicide Disinfection & Oxidation |
15mg/L |
| Calcium Hypochlorite 65% | Algicide Disinfection & Oxidation |
15mg/L |
| Calcium Hypochlorite 65-70% | Algicide Disinfection & Oxidation |
15mg/L |
| Calcium Hypochlorite 70% | Algicide Disinfection & Oxidation |
15mg/L |
| Chloro-Jal 65% | Algicide Disinfection & Oxidation |
15mg/L |
| Chloro-Jal 65-70% | Algicide Disinfection & Oxidation |
15mg/L |
| Chloro-Jal 70% | Algicide Disinfection & Oxidation |
15mg/L |
| NEER - CHLORO | Algicide Disinfection & Oxidation |
15mg/L |
| Neer-Chloro 65% | Algicide Disinfection & Oxidation |
15mg/L |
| Neer-Chloro 65-70% | Algicide Disinfection & Oxidation |
15mg/L |
| Neer-Chloro 70% | Algicide Disinfection & Oxidation |
15mg/L |
| SETZ - AQUA | Algicide Disinfection & Oxidation |
15mg/L |
| Setz-Aqua 65% | Algicide Disinfection & Oxidation |
15mg/L |
| Setz-Aqua 65-70% | Algicide Disinfection & Oxidation |
15mg/L |
| Setz-Aqua 70% | Algicide Disinfection & Oxidation |
15mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
|
Potassium Permanganate[PO] |
||
| Trade Designation | Product Function | Max Use |
| Potassium Permanganate | Oxidant | 50mg/L |
| Potassium Permanganate-Free Flowing | Oxidant | 50mg/L |
| Potassium Permanganate-Pure | Oxidant | 50mg/L |
| Potassium Permanganate-Technical | Oxidant | 50mg/L |
[PO] The finished drinking water shall be monitored to ensure that levels of manganese
do not exceed 0.05 mg/L.
|
||
|
Sodium Permanganate[PO] |
||
| Trade Designation | Product Function | Max Use |
| SP ORG 20 | Disinfection & Oxidation | 20mg/L |
| SP ORG 40 | Disinfection & Oxidation | 20mg/L |
[PO] The finished drinking water shall be monitored to ensure that levels of manganese
do not exceed 0.05 mg/L.
|
||
NOTE: All Listed products bearing the NSF Mark are NSF Certified.
| Orlov Greentech Private Limited | |
| 21, Darshan Building, Room No. 402 | |
| Raghunath Dadaji Street, Mumbai | |
| Maharashtra 400001 | |
| India | |
| 91 22 22683006 |
Facility : Panoli, Gujarat, India
|
Ferric Chloride |
||
| Trade Designation | Product Function | Max Use |
| Ferric Chloride Anhydrous | Coagulation & Flocculation | 100mg/L |
| Ferric Chloride Hexahydrate | Coagulation & Flocculation | 166mg/L |
| Ferric Chloride Liquid | Coagulation & Flocculation | 250mg/L |
| Orlov Greentech Private Limited | |
| 402 Darshan Bldg Fort | |
| Mumbai, Maharashtra 400025 | |
| India | |
| 91 981 9977709 |
Facility : Gujarat, India
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| OG 7002 | Reverse Osmosis Antiscalant | 20mg/L |
| OG 7002 A | Reverse Osmosis Antiscalant | 20mg/L |
|
Poly (Diallyldimethylammonium Chloride)(pDADMAC) |
||
| Trade Designation | Product Function | Max Use |
| ORLYTE 6031 | Coagulation & Flocculation | 5mg/L |
| ORLYTE 6032 | Coagulation & Flocculation | 5mg/L |
|
Polyamines[PY] |
||
| Trade Designation | Product Function | Max Use |
| OG 6020 | Coagulation & Flocculation | 1mg/L |
| OG 6021 | Coagulation & Flocculation | 1mg/L |
| OG 6022 | Coagulation & Flocculation | 1mg/L |
[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
percent monomer and dose.
|
||
|
Polymaleic Acid |
||
| Trade Designation | Product Function | Max Use |
| OG 7001S | Reverse Osmosis Antiscalant | 3mg/L |
| OG 7001W | Reverse Osmosis Antiscalant | 3mg/L |
|
Polymer Blends[AL] |
||
| Trade Designation | Product Function | Max Use |
| OG 6050 | Coagulation & Flocculation | 20mg/L |
| OG 6051 | Coagulation & Flocculation | 30mg/L |
| OG 6052 | Coagulation & Flocculation | 40mg/L |
| OG 6053 | Coagulation & Flocculation | 50mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
| Praj Hipurity Systems Limited | |
| 1811/ 1182, 8th Floor, Building No. 11, | |
| Solitaire Corporate Park, Andheri Ghatkopar Link Rd | |
| Andheri East, Maharashtra 400093 | |
| India | |
| 91 84 25861310 |
Facility : Maharashtra, India
|
Miscellaneous Treatment Applications |
||
| Trade Designation | Product Function | Max Use |
| PV-CHEM-111 | Reverse Osmosis Antiscalant | 20mg/L |
| PV-CHEM-222 | Reverse Osmosis Antiscalant | 20mg/L |
| PV-CHEM-333 | Reverse Osmosis Antiscalant | 20mg/L |
| PV-CHEM-666 | Reverse Osmosis Antiscalant | 20mg/L |
| PV-CHEM-999 | Reverse Osmosis Antiscalant | 20mg/L |
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| PV-BCLEAN-777[1] [2] | Reverse Osmosis Membrane Biocide | NA |
| PV-CLEAN-101[3] | Membrane Cleaner | NA |
| PV-CLEAN-102[3] | Membrane Cleaner | NA |
[1] When this product is used offline, it is designed to be flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[2] This product is certified to NSF/ANSI/CAN 60, but it has not been registered under the
US FIFRA requirements and is not to be distributed within the USA.
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
|
Sodium Hydroxide |
||
| Trade Designation | Product Function | Max Use |
| PV-TREAT-555 | pH Adjustment | 20mg/L |
| Pure Chemicals Co. | |
| No. 32, H Block, 15th Main Road | |
| Anna Nagar, West Chennai | |
| Tamil Nadu 600040 | |
| India | |
| 91 944 5393551 | |
| Visit this company's website |
Facility : Tamil Nadu, India
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| PURER RO 133 | Reverse Osmosis Antiscalant | 5mg/L |
| PURER RO 153 | Reverse Osmosis Antiscalant | 5mg/L |
| PURER RO 163 | Reverse Osmosis Antiscalant | 5mg/L |
|
Miscellaneous Water Supply Products[1] |
||
| Trade Designation | Product Function | Max Use |
| PURER RO 311 | Membrane Cleaner | NA |
| PURER RO 322 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
| Qemi International, Inc. | |
| 800 Rockmead Drive | |
| Suite 100 | |
| Kingwood, TX 77339 | |
| United States | |
| 281-359-8188 | |
| Visit this company's website |
Facility : India
|
Polyamines[PY] |
||
| Trade Designation | Product Function | Max Use |
| QEMICLAR VLC-C | 6mg/L | |
| QEMIFLOC FL 71 | 6mg/L | |
| QEMIFLOC FL 81 | 6mg/L | |
[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
percent monomer and dose.
|
||
| Radik Chemicals Pvt Ltd. | |
| 4 Synagogue Street, 6th Floor | |
| Room No. 603 | |
| Kolkata, West Bengal 700001 | |
| India | |
| 91 933 1840157 | |
| Visit this company's website |
Facility : Telangana, India
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| Aquaclean | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean 12 VD | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean 4036 | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean 4111 | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean 5 MG | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean 5046 | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean 5111 | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean 5L+ | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean 6001 | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean 6001T | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean 6046 | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean 6111 | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean 6510 | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean 6536 | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean 7 MG | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean 7001 | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean 7001 T | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean 7510 | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean 8536 | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean CVD | Reverse Osmosis Antiscalant | 15mg/L |
| Aquaclean Eco+ | Reverse Osmosis Antiscalant | 15mg/L |
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| Rakiro Biotech Systems Private Limited | |
| R466 TTC Industrial Area | |
| MIDC Rabale | |
| Navi Mumbai, Maharashtra 400701 | |
| India | |
| 91 222 7642236 | |
| Visit this company's website |
Facility : Navi Mumbai, India
|
Hydrogen Peroxide[HP] |
||
| Trade Designation | Product Function | Max Use |
| UDAAQ - WTROB800 | Reverse Osmosis Membrane Biocide | 20mg/L |
| UDAAQ - WTSH010 | Reverse Osmosis Membrane Biocide | 74mg/L |
| UDAAQ - WTSH020 | Reverse Osmosis Membrane Biocide | 38mg/L |
| UDAAQ - WTSH025 | Reverse Osmosis Membrane Biocide | 30mg/L |
| UDAAQ - WTSH035 | Reverse Osmosis Membrane Biocide | 22mg/L |
| UDAAQ - WTSH050 | Reverse Osmosis Membrane Biocide | 16mg/L |
[HP] Use of this product shall be followed by chlorination to remove levels of hydrogen
peroxide. Chlorine residuals shall not exceed 4 mg/L, the EPA's proposed maximum
residual level.
|
||
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| UDAAQ WTRD300 | Reverse Osmosis Antiscalant | 20mg/L |
| UDAAQ WTRD301 | Reverse Osmosis Antiscalant | 20mg/L |
| UDAAQ WTRD305 | Reverse Osmosis Antiscalant | 20mg/L |
| UDAAQ WTRD310 | Reverse Osmosis Antiscalant | 20mg/L |
| UDAAQ WTRD320 | Reverse Osmosis Antiscalant | 20mg/L |
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| UDAAQ WTROB 900[1] [2] | Reverse Osmosis Membrane Biocide | NA |
| UDAAQ WTROC1600[3] | Membrane Cleaner | NA |
| UDAAQ WTROC1800[3] | Membrane Cleaner | NA |
[1] When this product is used offline, it is designed to be flushed out prior to using the
system for drinking water, following manufacturer's use instructions.
[2] This product is certified to NSF/ANSI/CAN 60, but it has not been registered under the
US FIFRA requirements and is not to be distributed within the USA.
[3] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
|
Sodium Hydroxide |
||
| Trade Designation | Product Function | Max Use |
| UDAAQ P200 | pH Adjustment | 20mg/L |
| RAPID PURE TECHNOLOGIES | |
| TF-313, Town Plaza | |
| New India Colony | |
| Ahmedabad, Gujarat 382350 | |
| India | |
| 91 951 0651432 |
Facility : Noida, Uttar Pradesh, India
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| RIKEM 65 | Reverse Osmosis Antiscalant | 8mg/L |
| RIKEM 81 | Reverse Osmosis Antiscalant | 8mg/L |
| RIKEM 85 | Reverse Osmosis Antiscalant | 8mg/L |
| Rishabh Metals & Chemicals Pvt Ltd. | |
| Eros Theater Building, 4th Floor | |
| J. Tata Road, Mumbai 400020 | |
| India | |
| 91 22 40370000 | |
| Visit this company's website |
Facility : Jalgaon, India
|
Poly (Diallyldimethylammonium Chloride)(pDADMAC) |
||
| Trade Designation | Product Function | Max Use |
| RL 4040 PWG | Coagulation & Flocculation | 50mg/L |
| RL 4044 PWG | Coagulation & Flocculation | 25mg/L |
| RL 4052 PWG | Coagulation & Flocculation | 50mg/L |
| RL 4053 PWG | Coagulation & Flocculation | 33mg/L |
| RL 4054 PWG | Coagulation & Flocculation | 25mg/L |
| RL 4543 PWG | Coagulation & Flocculation | 33mg/L |
| RL 4544 PWG | Coagulation & Flocculation | 25mg/L |
| RL 4550 PWG | Coagulation & Flocculation | 50mg/L |
| RL 4554 PWG | Coagulation & Flocculation | 25mg/L |
| RL 4840 PWG | Coagulation & Flocculation | 50mg/L |
| RL 5040 PWG | Coagulation & Flocculation | 50mg/L |
| RL 5041 PWG | Coagulation & Flocculation | 50mg/L |
| RL 5043 PWG | Coagulation & Flocculation | 33mg/L |
| RL 5044 PWG | Coagulation & Flocculation | 25mg/L |
| RL 5045 PWG | Coagulation & Flocculation | 25mg/L |
| RL 5115 PWG | Coagulation & Flocculation | 25mg/L |
| RL 5116 PWG | Coagulation & Flocculation | 50mg/L |
| RL 5560 PWG | Coagulation & Flocculation | 25mg/L |
| RL 5561 PWG | Coagulation & Flocculation | 50mg/L |
| RL 5814 PWG | Coagulation & Flocculation | 50mg/L |
| RL 5815 PWG | Coagulation & Flocculation | 50mg/L |
| RL 5816 PWG | Coagulation & Flocculation | 50mg/L |
| RL 5817 PWG | Coagulation & Flocculation | 50mg/L |
| RL 5833 PWG | Coagulation & Flocculation | 33mg/L |
| RL 5850 PWG | Coagulation & Flocculation | 50mg/L |
| RL 5854 PWG | Coagulation & Flocculation | 25mg/L |
| RL 8040 PWG | Coagulation & Flocculation | 50mg/L |
| RL 8044 PWG | Coagulation & Flocculation | 25mg/L |
| RL 8050 PWG | Coagulation & Flocculation | 50mg/L |
| RL 8053 PWG | Coagulation & Flocculation | 33mg/L |
| RL 8054 PWG | Coagulation & Flocculation | 25mg/L |
|
Polyamines[PY] |
||
| Trade Designation | Product Function | Max Use |
| RL 5524 | Coagulation & Flocculation | 6mg/L |
| RL 5530 PWG | Coagulation & Flocculation | 6mg/L |
| RL 5538 PWG | Coagulation & Flocculation | 6mg/L |
| RL 5610 | Coagulation & Flocculation | 6mg/L |
| RL 5611 PWG | Coagulation & Flocculation | 6mg/L |
| RL 5612 | Coagulation & Flocculation | 6mg/L |
| RL 5613 PWG | Coagulation & Flocculation | 6mg/L |
| RL 5614 PWG | Coagulation & Flocculation | 6mg/L |
| RL 5615 PWG | Coagulation & Flocculation | 6mg/L |
| RL 5616 PWG | Coagulation & Flocculation | 6mg/L |
| RL 5617 PWG | Coagulation & Flocculation | 6mg/L |
| RL 5618 PWG | Coagulation & Flocculation | 6mg/L |
| RL 5619 PWG | Coagulation & Flocculation | 6mg/L |
| RL 5620 PWG | Coagulation & Flocculation | 6mg/L |
| RL 5621 PWG | Coagulation & Flocculation | 6mg/L |
| RL 5622 PWG | Coagulation & Flocculation | 6mg/L |
| RL 5818 PWG | Coagulation & Flocculation | 6mg/L |
| RL 8018 PWG | Coagulation & Flocculation | 6mg/L |
| RL 9813 PWG | Coagulation & Flocculation | 6mg/L |
| RL 9958 PWG | Coagulation & Flocculation | 6mg/L |
| RL-8022 PWG | Coagulation & Flocculation | 6mg/L |
| RL-8028 PWG | Coagulation & Flocculation | 6mg/L |
| RL-9922 PWG | Coagulation & Flocculation | 6mg/L |
| RL-9928 PWG | Coagulation & Flocculation | 6mg/L |
[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
percent monomer and dose.
|
||
| Shikoku India Private Limited | |
| No. 7,17th Cross, Off Margosa Rd | |
| Malleswaram West | |
| Bengaluru, Karnataka 560055 | |
| India | |
| 91 9073740495 | |
| Visit this company's website |
Facility : Bengaluru, India
|
Sodium Dichloroisocyanurate[CL] |
||
| Trade Designation | Product Function | Max Use |
| INSTAPURE | Disinfection & Oxidation | 30mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| SHREE CHLORATES PRIVATE LIMITED | |
| 101-102 Block B, Radhakrishna Complex | |
| 10/1, Manoramaganj, Indore (MP) 452001 | |
| India | |
| 91 731 249 0172 | |
| Visit this company's website |
Facility : Dist. Dhar/MP, India
|
Sodium Chlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| SCN 1025 | Chlorine Dioxide Production | 28mg/L |
| SCN 1031 | Chlorine Dioxide Production | 22mg/L |
| SCN 1075 | Chlorine Dioxide Production | 93mg/L |
| SCN 1080 | Chlorine Dioxide Production | 9mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| SNF Flopam India Pvt. Ltd. | |
| Survey No. 141-1-2-N-142-1, NH | |
| 8/A East, Varsana, PO Gopalpuri | |
| Gandhidham (Kutch) Gujarat 370240 | |
| India | |
| 91 02836 272100 | |
| Visit this company's website |
Facility : Gujarat, India
|
Polyacrylamide[PC] |
||
| Trade Designation | Product Function | Max Use |
| FLOPAM™ AN 910 PWG | Coagulation & Flocculation | 1mg/L |
| FLOPAM™ AN 934 PWG | Coagulation & Flocculation | 1mg/L |
| FLOPAM™ AN 934 SHU PWG | Coagulation & Flocculation | 1mg/L |
| FLOPAM™ AN 945 K VHM PWG | Coagulation & Flocculation | 1mg/L |
[PC] Polyacrylamide Products Certified by NSF International comply with 40 CFR 141.111
requirements for percent monomer and dose.
|
||
|
Polyacrylic Acid |
||
| Trade Designation | Product Function | Max Use |
| FLOSPERSE™ 1055 BM PWG | Distillation Antiscalant Reverse Osmosis Antiscalant |
20mg/L |
|
Sodium Polyacrylate |
||
| Trade Designation | Product Function | Max Use |
| FLOPAM™ AN 995 BPM PWG | Flocculant | 1mg/L |
| FLOPAM™ AN 995 BPM PWG | Distillation Antiscalant Reverse Osmosis Antiscalant |
9mg/L |
| SNF India Pvt. Ltd | |
| Plot No.19, JNPC Parawada | |
| Visakhaptanam, AP 531019 | |
| India | |
| 11 91 8048370192 | |
| Visit this company's website |
Facility : Visakhaptanam, India
|
Poly (Diallyldimethylammonium Chloride)(pDADMAC) |
||
| Trade Designation | Product Function | Max Use |
| FLOQUAT FL 4440 PWG | Coagulation & Flocculation | 25mg/L |
| FLOQUAT FL 4520 PWG | Coagulation & Flocculation | 50mg/L |
| FLOQUAT FL 4540 PWG | Coagulation & Flocculation | 25mg/L |
| Solenis LLC | |
| 500 Hercules Road | |
| Wilmington, DE 19808 | |
| United States | |
| 302-594-5000 | |
| Visit this company's website |
Facility : Ankleshwar, Gujarat, India
|
Aluminum Chlorohydrate[AL] |
||
| Trade Designation | Product Function | Max Use |
| Chargepac 55-IN | Coagulation & Flocculation | 250mg/L |
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Aminotrimethylene Phosphonic Acid |
||
| Trade Designation | Product Function | Max Use |
| Ameroyal AS1515-AP-N | Reverse Osmosis Antiscalant | 10mg/L |
| Ameroyal C1000[1] | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
|
||
|
Citric Acid[1] [2] |
||
| Trade Designation | Product Function | Max Use |
| Ameroyal 8301 | Membrane Cleaner | N/A |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Diethylenetriamine penta (methylene phosphonic) ac |
||
| Trade Designation | Product Function | Max Use |
| Ameroyal 710 | Reverse Osmosis Antiscalant | 10mg/L |
|
Hydroxyethylidene Diphosphonic Acid |
||
| Trade Designation | Product Function | Max Use |
| Ameroyal 428C-N | Reverse Osmosis Antiscalant | 10mg/L |
| Ameroyal 428I-N | Reverse Osmosis Antiscalant | 10mg/L |
|
Miscellaneous Treatment Applications[3] |
||
| Trade Designation | Product Function | Max Use |
| Antispumin DS | Antifoamer | 5mg/L |
[3] Certified for addition to the feedwater for evaporative desalination units only. |
||
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| POC 3000-AP | Distillation Antiscalant | 20mg/L |
|
Sodium Metabisulfite[4] |
||
| Trade Designation | Product Function | Max Use |
| Ameroyal RCR | Dechlorinator & Antioxidant | 15mg/L |
[4] This product contains sulfite. Sulfites have been known to cause potentially lethal
allergic reactions in sulfite-sensitive individuals. The maximum recommended allowable
residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).
|
||
| Solenis LLC | |
| 500 Hercules Road | |
| Wilmington, DE 19808 | |
| United States | |
| 302-594-5000 |
Facility : # 2 India
|
Calcium Hypochlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| BIOSPERSE CH70G CHLORINE GRANULES | Algicide Disinfection & Oxidation |
10mg/L |
| Biosperse CH70-G | Algicide Disinfection & Oxidation |
10mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| Speed International India Private Limited | |
| Plot No. 15/16 & 21/23, MIDC, Old Swastik | |
| Soap Factory, Chikloli, Moraveli, Ambernath West | |
| Thane, Maharashtra 421501 | |
| India | |
| 91 9930275217 | |
| Visit this company's website |
Facility : Maharashtra, India
|
Potassium Permanganate[PO] |
||
| Trade Designation | Product Function | Max Use |
| Potassium Permanganate Free Flowing Grade | Oxidant Disinfection & Oxidation |
50mg/L |
| Potassium Permanganate Pure Grade | Oxidant Disinfection & Oxidation |
50mg/L |
| Potassium Permanganate Technical Grade | Oxidant Disinfection & Oxidation |
50mg/L |
[PO] The finished drinking water shall be monitored to ensure that levels of manganese
do not exceed 0.05 mg/L.
|
||
|
Sodium Permanganate[PO] |
||
| Trade Designation | Product Function | Max Use |
| Sodium Permanganate 20% Solution | Oxidant Disinfection & Oxidation |
98mg/L |
| Sodium Permanganate 40% Solution | Oxidant Disinfection & Oxidation |
49mg/L |
[PO] The finished drinking water shall be monitored to ensure that levels of manganese
do not exceed 0.05 mg/L.
|
||
| Sree Rayalaseema Hi-Strength Hypo Limited | |
| 216 K.J.S. Complex | |
| Bhagya Nagar, Kurnool | |
| Andhra Pradesh 518 004 | |
| India | |
| 91 8518 228750 | |
| Visit this company's website |
Facility : Andhra Pradesh, India
|
Calcium Hypochlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| Aquachlor - 65% | Disinfection & Oxidation | 8mg/L |
| Aquachlor - 70% | Disinfection & Oxidation | 8mg/L |
| Aquafine - 65% | Disinfection & Oxidation | 8mg/L |
| Aquafine - 70% | Disinfection & Oxidation | 8mg/L |
| Aquafit 65% | Disinfection & Oxidation | 8mg/L |
| Aquafit 70% | Disinfection & Oxidation | 8mg/L |
| Aquafresh - 65% | Disinfection & Oxidation | 8mg/L |
| Aquafresh - 70% | Disinfection & Oxidation | 8mg/L |
| Aquapure - 65% | Disinfection & Oxidation | 8mg/L |
| Aquapure - 70% | Disinfection & Oxidation | 8mg/L |
| Aquastar - 65% | Disinfection & Oxidation | 8mg/L |
| Aquastar - 70% | Disinfection & Oxidation | 8mg/L |
| CRYSTACHLOR | Disinfection & Oxidation Algicide |
8mg/L |
| Calcium Hypochlorite-65% | Disinfection & Oxidation | 8mg/L |
| Calcium Hypochlorite-70% | Disinfection & Oxidation | 8mg/L |
| Poolfit - 65% | Disinfection & Oxidation | 8mg/L |
| Poolfit - 70% | Disinfection & Oxidation | 8mg/L |
| Purichlor - 65% | Disinfection & Oxidation | 8mg/L |
| Purichlor - 70% | Disinfection & Oxidation | 8mg/L |
| SANICHLOR | Disinfection & Oxidation Algicide |
8mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
NOTE: Only products bearing the NSF Mark on the product, product packaging, and/or
documentation shipped with the product are Certified.
| Star Oxochem Pvt Ltd. | |
| Plot No. 756/10 A & 756/10 B | |
| Road No. 6, GIDC, Jhagadia | |
| Bharuch, Gujarat 393110 | |
| India | |
| 91 971 4999446 |
Facility : Bharuch, Gujarat, India
|
Potassium Permanganate[1] [2] [PO] |
||
| Trade Designation | Product Function | Max Use |
| POTASSIUM PERMANGANATE (Free Flowing Grade) | Disinfection & Oxidation | 50mg/L |
| POTASSIUM PERMANGANATE (Pure Grade) | Disinfection & Oxidation | 50mg/L |
| POTASSIUM PERMANGANATE (Technical Grade) | Disinfection & Oxidation | 50mg/L |
[1] The finished drinking water should be monitored to ensure that levels of manganese do
not exceed 0.05 mg/L.
[2] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water should not exceed 2 mg/L.
[PO] The finished drinking water shall be monitored to ensure that levels of manganese
do not exceed 0.05 mg/L.
|
||
| Sukha Chemical Industries | |
| Plot No. 4705/1/6 & 7 | |
| Nr Meghmani Chowkdi, GIDC Estate | |
| Ankleshwar, Gujarat 393002 | |
| India | |
| 91 264 6225067 | |
| Visit this company's website |
Facility : Gujarat, India
|
Ferric Chloride |
||
| Trade Designation | Product Function | Max Use |
| Ferric Chloride Anhydrous | Coagulation & Flocculation | 100mg/L |
| Ferric Chloride Hexahydrate | Coagulation & Flocculation | 166mg/L |
| Ferric Chloride Liquid | Coagulation & Flocculation | 250mg/L |
| SVS AQUA TECHNOLOGIES LLP | |
| Shop No. 2, Ground Floor | |
| Mahavir Palace, 520 New Rasta Peth | |
| Pune, Maharashtra 411011 | |
| India | |
| 91 202 6127098 | |
| Visit this company's website |
Facility : Maharashtra, India
|
Chlorine Dioxide Ingredients[1] [CL] |
||
| Trade Designation | Product Function | Max Use |
| CDD 5000™ | Disinfection & Oxidation Algicide Bactericide |
50mg/L |
[1] Component A and Component B are to be mixed following manufacturer's use instructions to
produce a 1% chlorine dioxide solution. Certification and maximum use level applies to
the finished product.
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| Tech Team | |
| 28-Ramachandriah Colony | |
| West Venkatapuram, Secunderabad | |
| Telangana, Hyderabad 500015 | |
| India | |
| 919849026065 | |
| Visit this company's website |
Facility : India
|
Hydrogen Peroxide[HP] |
||
| Trade Designation | Product Function | Max Use |
| TRIOZON F | Disinfection & Oxidation | 16mg/L |
| TRIOZON P | Disinfection & Oxidation | 266mg/L |
| TRIOZON P 12% | Disinfection & Oxidation | 66mg/L |
[HP] Use of this product shall be followed by chlorination to remove levels of hydrogen
peroxide. Chlorine residuals shall not exceed 4 mg/L, the EPA's proposed maximum
residual level.
|
||
| Thermax Limited (Chemical Division) | |
| 97 East General Block | |
| Bhosari-Pune - 411026 | |
| India | |
| 91 20 7120181 |
Facility : Jhagadia, Gujarat, India
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| FOAMIN KU N[1] | Antifoamer | 2mg/L |
| FOAMIN OM N[1] | Antifoamer | 2mg/L |
| Maxtreat-9001 N | Reverse Osmosis Antiscalant | 6mg/L |
| Maxtreat-9002 N | Reverse Osmosis Antiscalant | 6mg/L |
| Maxtreat-9115 N | Reverse Osmosis Antiscalant | 10mg/L |
| Maxtreat-9123 N | Reverse Osmosis Antiscalant | 10mg/L |
| Scalemin 1555 N | Distillation Antiscalant | 8mg/L |
| Scalemin 3009 N | Distillation Antiscalant Reverse Osmosis Antiscalant |
6mg/L |
| Scalemin 4917 N | Distillation Antiscalant | 13mg/L |
[1] This product is to be added to the feedwater of evaporator type units only. |
||
|
Poly (Diallyldimethylammonium Chloride)(pDADMAC) |
||
| Trade Designation | Product Function | Max Use |
| Maxfloc T N | Coagulation & Flocculation | 8mg/L |
|
Polyacrylamide[PC] |
||
| Trade Designation | Product Function | Max Use |
| Maxfloc 3143 N | Coagulation & Flocculation | 0.6mg/L |
[PC] Polyacrylamide Products Certified by NSF International comply with 40 CFR 141.111
requirements for percent monomer and dose.
|
||
| Universal Chemicals & Industries Private Limited | |
| 507, Raheja Centre | |
| 214 Nariman Point | |
| Mumbai, 400 021 | |
| India | |
| 91 22 22 84 44 28 |
Facility : Dahej, Gujarat State, India
|
Potassium Permanganate[PO] |
||
| Trade Designation | Product Function | Max Use |
| Potassium Permanganate | Oxidant | 50mg/L |
| Potassium Permanganate (Crystal Grade Min. 99%) | Oxidant | 50mg/L |
| Potassium Permanganate (Free Flowing Grade Min. 97%) | Oxidant | 50mg/L |
| Potassium Permanganate (Pure Bold Grade 99%) | Oxidant | 50mg/L |
| Potassium Permanganate (Pure Crystalline Grade Min. 99%) | Oxidant | 50mg/L |
| Potassium Permanganate (Pure Grade Min. 99%) | Oxidant | 50mg/L |
| Potassium Permanganate (Technical Grade Min. 98% and Min. 99%) | Oxidant | 50mg/L |
[PO] The finished drinking water shall be monitored to ensure that levels of manganese
do not exceed 0.05 mg/L.
|
||
| Universal Chemicals & Industries Private Limited | |
| 507, Raheja Centre | |
| 214 Nariman Point | |
| Mumbai, Maharashtra 400021 | |
| India | |
| 91 987 0427281 |
Facility : Maharashtra, India
|
Sodium Permanganate |
||
| Trade Designation | Product Function | Max Use |
| SODIUM PERMANGANATE 20% | Disinfection & Oxidation Oxidant |
98mg/L |
| SODIUM PERMANGANATE 40% | Disinfection & Oxidation Oxidant |
49mg/L |
| Vasu Chemicals LLP | |
| Vasu Centre, Military Road | |
| Marol, Andheri East, Mumbai | |
| Maharashtra 400059 | |
| India | |
| 91 226 1449500 | |
| Visit this company's website |
Facility : Maharashtra, India
|
Sodium Chlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| Bionil-242C | Bactericide Disinfection & Oxidation |
20mg/L |
| Bionil-251C | Bactericide Disinfection & Oxidation |
25mg/L |
| Bionil-252C | Bactericide Disinfection & Oxidation |
25mg/L |
| Bionil-253C | Bactericide Disinfection & Oxidation |
25mg/L |
| Bionil-254C | Bactericide Disinfection & Oxidation |
25mg/L |
| Bionil-255C | Bactericide Disinfection & Oxidation |
25mg/L |
| Bionil-256C | Bactericide Disinfection & Oxidation |
25mg/L |
| Bionil-257C | Bactericide Disinfection & Oxidation |
25mg/L |
| Bionil-258C | Bactericide Disinfection & Oxidation |
25mg/L |
| Bionil-259C | Bactericide Disinfection & Oxidation |
25mg/L |
| Bionil-274C | Bactericide Disinfection & Oxidation |
20mg/L |
| Bionil-311C | Bactericide Disinfection & Oxidation |
20mg/L |
| Bionil-312C | Bactericide Disinfection & Oxidation |
20mg/L |
| Bionil-313C | Bactericide Disinfection & Oxidation |
20mg/L |
| Bionil-314C | Bactericide Disinfection & Oxidation |
20mg/L |
| Bionil-315C | Bactericide Disinfection & Oxidation |
20mg/L |
| Bionil-316C | Bactericide Disinfection & Oxidation |
20mg/L |
| Bionil-317C | Bactericide Disinfection & Oxidation |
20mg/L |
| Bionil-318C | Bactericide Disinfection & Oxidation |
20mg/L |
| Bionil-319C | Bactericide Disinfection & Oxidation |
20mg/L |
| Bionil-762C | Bactericide Disinfection & Oxidation |
20mg/L |
| Bionil-775C | Bactericide Disinfection & Oxidation |
20mg/L |
| Bionil-801C | Bactericide Disinfection & Oxidation |
8mg/L |
| Bionil-802C | Bactericide Disinfection & Oxidation |
8mg/L |
| Bionil-803C | Bactericide Disinfection & Oxidation |
8mg/L |
| Bionil-824C | Bactericide Disinfection & Oxidation |
20mg/L |
| Bionil-825C | Bactericide Disinfection & Oxidation |
20mg/L |
| Bionil-849C | Bactericide Disinfection & Oxidation |
20mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| Veolia Water Technologies & Solutions | |
| 3600 Horizon Boulevard | |
| Trevose, PA 19053 | |
| United States | |
| 215-355-3300 | |
| Visit this company's website |
Facility : Bangalore, India
|
Aluminum Chlorohydrate[5] [AL] |
||
| Trade Designation | Product Function | Max Use |
| Klaraid IC1172P | Coagulation & Flocculation | 250mg/L |
| Solisep MPT103 | Coagulation & Flocculation | 250mg/L |
[5] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
|
||
|
Citric Acid[1] [5] |
||
| Trade Designation | Product Function | Max Use |
| BETZ MPH5000[2] | Membrane Cleaner | NA |
| MemChem MCT201 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[5] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Chemical Products[5] |
||
| Trade Designation | Product Function | Max Use |
| FLOGARD POT6102 | Corrosion & Scale Control | 27mg/L |
[5] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Treatment Chemical[5] |
||
| Trade Designation | Product Function | Max Use |
| Aquamax HT20 | Distillation Antiscalant | 10mg/L |
| Aquamax LT-19i | Distillation Antiscalant | 10mg/L |
| Aquamax LT19 | Distillation Antiscalant | 10mg/L |
| HYPERSPERSE MDC712 | Reverse Osmosis Antiscalant | 5mg/L |
| HYPERSPERSE MSI300J | Distillation Antiscalant Reverse Osmosis Antiscalant |
10mg/L |
| Hypersperse AF150UL | Distillation Antiscalant Reverse Osmosis Antiscalant |
6mg/L |
| Hypersperse AF200UL | Distillation Antiscalant Reverse Osmosis Antiscalant |
6mg/L |
| Hypersperse AF220UL | Distillation Antiscalant Reverse Osmosis Antiscalant |
6mg/L |
| Hypersperse AF240UL | Distillation Antiscalant Reverse Osmosis Antiscalant |
6mg/L |
| Hypersperse MDC150 | Distillation Antiscalant Reverse Osmosis Antiscalant |
6mg/L |
| Hypersperse MDC170 | Distillation Antiscalant Reverse Osmosis Antiscalant |
6mg/L |
| Hypersperse MDC200 | Distillation Antiscalant Reverse Osmosis Antiscalant |
6mg/L |
| Hypersperse MDC220 | Distillation Antiscalant Reverse Osmosis Antiscalant |
6mg/L |
| Hypersperse MDC700 | Distillation Antiscalant Reverse Osmosis Antiscalant |
6mg/L |
| Hypersperse MDC704I | Reverse Osmosis Antiscalant | 12mg/L |
| Hypersperse MDC711 | Reverse Osmosis Antiscalant | 10mg/L |
| Hypersperse MDC712L | Reverse Osmosis Antiscalant | 5mg/L |
| Hypersperse MS1300 | Distillation Antiscalant Reverse Osmosis Antiscalant |
6mg/L |
| Hypersperse MSI310 | Distillation Antiscalant Reverse Osmosis Antiscalant |
6mg/L |
| Hypersperse MSI410 | Distillation Antiscalant Reverse Osmosis Antiscalant |
10mg/L |
| Hypersperse MSI430 | Reverse Osmosis Antiscalant | 10mg/L |
| Hypersperse S1300UL | Distillation Antiscalant Reverse Osmosis Antiscalant |
6mg/L |
| Scaletrol DS8730 | Distillation Antiscalant | 10mg/L |
| Scaletrol DS8733 | Distillation Antiscalant | 10mg/L |
[5] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products [5] |
||
| Trade Designation | Product Function | Max Use |
| Aquamax AF[3] | Antifoamer | 5mg/L |
| Aquamax DSL9915 | Antifoamer | 10mg/L |
[3] Certified for addition to the feedwater for evaporative desalination units only.
[5] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products[1] [5] |
||
| Trade Designation | Product Function | Max Use |
| BIOMATE MBC2881E | Reverse Osmosis Membrane Biocide | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[5] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products [5] |
||
| Trade Designation | Product Function | Max Use |
| Hypersperse MDC704 | Reverse Osmosis Antiscalant | 10mg/L |
| Hypersperse MDC706 | Reverse Osmosis Antiscalant | 10mg/L |
| Hypersperse MDC714 | Reverse Osmosis Antiscalant | 10mg/L |
[3] Certified for addition to the feedwater for evaporative desalination units only.
[5] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Miscellaneous Water Supply Products[1] [5] |
||
| Trade Designation | Product Function | Max Use |
| KLEEN MCT105[2] | Membrane Cleaner | NA |
| KLEEN MCT115 | Membrane Cleaner | NA |
| KLEEN MCT405[2] | Membrane Cleaner | NA |
| Kleen MCT515 | Membrane Cleaner | NA |
[1] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[2] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
[5] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Polyacrylamide[5] [PC] |
||
| Trade Designation | Product Function | Max Use |
| BETZDEARBORN AP1100P | Coagulation & Flocculation | 1mg/L |
| BETZDEARBORN AP1120P | Coagulation & Flocculation | 1mg/L |
| FoodPro SA9846 | Coagulation & Flocculation | 1mg/L |
[5] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
[PC] Polyacrylamide Products Certified by NSF International comply with 40 CFR 141.111
requirements for percent monomer and dose.
|
||
|
Polyamines[5] [PY] |
||
| Trade Designation | Product Function | Max Use |
| Coagulant 80B | Coagulation & Flocculation | 10mg/L |
| Klaraid PC1190P | Coagulation & Flocculation | 10mg/L |
| Klaraid PC1195P | Coagulation & Flocculation | 10mg/L |
| Polymer 1195P | Coagulation & Flocculation | 10mg/L |
[5] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
percent monomer and dose.
|
||
|
Polymer Blends[5] [AL] |
||
| Trade Designation | Product Function | Max Use |
| Klaraid CDP1336P[PY] | Coagulation & Flocculation | 130mg/L |
| Klaraid CDP1337P[PY] | Coagulation & Flocculation | 33mg/L |
| Klaraid CDP1339P[PY] | Coagulation & Flocculation | 100mg/L |
| Solisep MPT134 | Coagulation & Flocculation | 130mg/L |
[5] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
[AL] Based on an evaluation of health effects data, the level of aluminum in the finished
drinking water shall not exceed 2 mg/L.
[PY] Polyamines Certified by NSF International comply with 40 CFR 141.111 requirements for
percent monomer and dose.
|
||
|
Sodium Bisulfite [5] |
||
| Trade Designation | Product Function | Max Use |
| BETZDEARBORN DCL32[4] | Antioxidant Dechlorination |
15mg/L |
[4] This product contains sulfite. Sulfites have been known to cause potentially lethal
allergic reactions in sulfite-sensitive individuals. The maximum recommended allowable
residual sulfite level in the finished drinking water is 100 ppb (0.1 mg/L).
[5] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
|
||
|
Zinc Orthophosphate[5] [ZN] |
||
| Trade Designation | Product Function | Max Use |
| BETZ MUNI7612 | Corrosion & Scale Control | 6mg/L |
| Flogard POT6101 | Corrosion & Scale Control | 6mg/L |
| Flogard POT802 | Corrosion & Scale Control | 6mg/L |
[5] For products distributed in Canada, the company name on the product label may be shown
as Veolia Water Technologies & Solutions Canada GP, Oakville, ON.
[ZN] Based on an evaluation of health effects data, the level of zinc in the finished
drinking water shall not exceed 2.0 mg/L.
|
||
| Water Solutions Unlimited | |
| 8824 Union Mills Drive | |
| Camby, IN 46113 | |
| United States | |
| 800-359-3570 |
Facility : # 10 India
|
Calcium Hypochlorite [CL] |
||
| Trade Designation | Product Function | Max Use |
| Crystal Clear 68 [1] | Disinfection & Oxidation | 10mg/L |
[1] Component A and Component B are to be mixed following manufacturer's use instructions to
produce a 1% chlorine dioxide solution. Certification and maximum use level applies to
the finished product.
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| Water Solutions Unlimited | |
| 8824 Union Mills Drive | |
| Camby, IN 46113 | |
| United States | |
| 317-339-6639 | |
| Visit this company's website |
Facility : # 13 India
|
Potassium Permanganate[PO] |
||
| Trade Designation | Product Function | Max Use |
| WSU Potassium Permanganate | Oxidant | 50mg/L |
| WSU Potassium Permanganate (FF) | Oxidant | 50mg/L |
| WSU Potassium Permanganate (Tech) | Oxidant | 50mg/L |
[PO] The finished drinking water shall be monitored to ensure that levels of manganese
do not exceed 0.05 mg/L.
|
||
| Water Solutions Unlimited, Inc | |
| 8824 Union Mills Drive | |
| Camby, IN 46113 | |
| United States | |
| 317-736-6868 | |
| Visit this company's website |
Facility : #7 India
|
Sodium Permanganate[PO] |
||
| Trade Designation | Product Function | Max Use |
| WSU 40% Sodium Permanganate | Disinfection & Oxidation | 88mg/L |
[PO] The finished drinking water shall be monitored to ensure that levels of manganese
do not exceed 0.05 mg/L.
|
||
| Water Solutions Unlimited, Inc. | |
| 8824 Union Mills Drive | |
| Camby, IN 46113 | |
| United States | |
| 800-359-3570 | |
| 317-736-6868 | |
| Visit this company's website |
Facility : # 12 India
|
Potassium Permanganate[PO] |
||
| Trade Designation | Product Function | Max Use |
| WSU Potassium Permanganate (F.F.G.) | Oxidant | 50mg/L |
| WSU Potassium Permanganate (Technical) | Oxidant | 50mg/L |
[PO] The finished drinking water shall be monitored to ensure that levels of manganese
do not exceed 0.05 mg/L.
|
||
| Water Solutions Unlimited, Inc. | |
| 8824 Union Mills Drive | |
| Camby, IN 46113 | |
| United States | |
| 800-359-3570 | |
| 317-736-6868 | |
| Visit this company's website |
Facility : # 6 India
|
Potassium Permanganate[PO] |
||
| Trade Designation | Product Function | Max Use |
| WSU Potassium Permanganate Pure Grade | Oxidant | 50mg/L |
| WSU Potassium Permanganate (FF) | Oxidant | 50mg/L |
| WSU Potassium Permanganate (Tech) | Oxidant | 50mg/L |
| WSU Potassium Permanganate Free Flowing Potassium | Oxidant | 50mg/L |
| WSU Potassium Permanganate Pure | Oxidant | 50mg/L |
| WSU Potassium Permanganate Technic | Oxidant | 50mg/L |
[PO] The finished drinking water shall be monitored to ensure that levels of manganese
do not exceed 0.05 mg/L.
|
||
| Wex Technologies Pvt. Ltd. | |
| Survey No. 244./2, Rajiv Gandhi | |
| Infotech Park, Phase-1, Hinjawadi | |
| Pune 411057, Landmark: Near Sai | |
| Service Station, | |
| India | |
| 91 206 6547000 | |
| Visit this company's website |
Facility : Maharashtra, India
|
Aminotrimethylene Phosphonic Acid |
||
| Trade Designation | Product Function | Max Use |
| GENESYS HR | Reverse Osmosis Antiscalant | 5mg/L |
| Genesys MP | Reverse Osmosis Antiscalant | 10mg/L |
|
Miscellaneous Corrosion Chemicals |
||
| Trade Designation | Product Function | Max Use |
| Genetech CP | Corrosion Control | 25mg/L |
|
Miscellaneous Treatment Chemical |
||
| Trade Designation | Product Function | Max Use |
| CHEMSOL 27 | Distillation Antiscalant | 10mg/L |
| Genesys CAS | Reverse Osmosis Antiscalant | 10mg/L |
| Genesys LF | Reverse Osmosis Antiscalant | 10mg/L |
| Genesys LF 60 | Reverse Osmosis Antiscalant | 10mg/L |
| Genesys LS | Reverse Osmosis Antiscalant | 10mg/L |
| Genesys SI | Reverse Osmosis Antiscalant | 10mg/L |
| WexTreat 27 | Distillation Antiscalant | 10mg/L |
|
Miscellaneous Water Supply Products |
||
| Trade Designation | Product Function | Max Use |
| CHEMSOL 63[1] | Antifoamer | .25mg/L |
| Genesol 38[2] [3] | Membrane Cleaner | NA |
| Genesol 40[2] [3] | Membrane Cleaner | NA |
| Genesol 703[2] [3] | Membrane Cleaner | NA |
| Genesol 704[2] [3] | Membrane Cleaner | NA |
| Genesol 721[2] [3] | Membrane Cleaner | NA |
| Genesol 80[2] | Membrane Cleaner | NA |
| Genesol UF Fe[2] | Membrane Cleaner | NA |
| Opticlean B[2] | Membrane Cleaner | NA |
| WexTreat AF 63[1] | Antifoamer | .25mg/L |
[1] Certified for addition to the feedwater for evaporative desalination units only.
[2] This product is designed to be used off-line and flushed out prior to using the system
for drinking water, following manufacturer's use instructions.
[3] The pH of the influent and effluent water should be monitored to ensure that all traces
of the product have been removed before placing into service.
|
||
|
Sodium Chlorite[CL] |
||
| Trade Designation | Product Function | Max Use |
| Chemsol 7214 | Chlorine Dioxide Production | 22mg/L |
[CL] The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine
dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the
finished drinking water to ensure compliance to all applicable regulations.
|
||
| Wintersun International | |
| 1250 East Belmont Street | |
| Ontario, CA 91761 | |
| United States | |
| 800-930-1688 | |
| 909-930-1688 | |
| Visit this company's website |
Facility : # 1 India
|
Potassium Permanganate[PO] |
||
| Trade Designation | Product Function | Max Use |
| POTASSIUM PERMANGANATE | Oxidant | 50mg/L |
| POTASSIUM PERMANGANATE - FFG GRADE | Oxidant | 50mg/L |
| POTASSIUM PERMANGANATE - PURE GRADE | Oxidant | 50mg/L |
| POTASSIUM PERMANGANATE - TECHNICAL GRADE | Oxidant | 50mg/L |
[PO] The finished drinking water shall be monitored to ensure that levels of manganese
do not exceed 0.05 mg/L.
|
||
| Wintersun International | |
| 1250 East Belmont Street | |
| Ontario, CA 91761 | |
| United States | |
| 800-930-1688 | |
| 909-930-1688 | |
| Visit this company's website |
Facility : # 1 India
|
Sodium Permanganate[1] |
||
| Trade Designation | Product Function | Max Use |
| Arisol 20 (Sodium Permanganate Solution 20%) | Disinfection & Oxidation Oxidant |
176mg/L |
| Arisol 40 (Sodium Permanganate Solution 40%) | Disinfection & Oxidation Oxidant |
88mg/L |
[1] The finished drinking water shall be monitored to ensure that levels of manganese do not
exceed 0.05 mg/L.
|
||
Number of matching Manufacturers is 71
Number of matching Products is 700